Lotek Wireless SRX600 Telmetry Receiver User Manual Guide to Keypad and LCD display

Lotek Wireless, Inc Telmetry Receiver Guide to Keypad and LCD display

Contents

Guide to Keypad and LCD display

Download: Lotek Wireless SRX600 Telmetry Receiver User Manual Guide to Keypad and LCD display
Mirror Download [FCC.gov]Lotek Wireless SRX600 Telmetry Receiver User Manual Guide to Keypad and LCD display
Document ID586907
Application IDtBliVwBe0LZ+JRgN/8KokA==
Document DescriptionGuide to Keypad and LCD display
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.11kB (263873 bits)
Date Submitted2005-09-29 00:00:00
Date Available2005-09-29 00:00:00
Creation Date2004-08-11 13:51:00
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2005-03-16 13:29:58
Document TitleGuide to SRX 600 Keypad and LCD Display Rev D #10055.fm
Document CreatorFrameMaker 7.0
Document Author: Janelle

1 of 20
Guide to the SRX 600 Keypad and LCD Display
Revision D, #10055, March 16th, 2005
2 of 20
UNDERSTANDING THE LCD/KEYPAD LAYOUT
The keypad and LCD display define the interface through which the receiver is programmed. The program is designed like a hierarchy. All aspects of the
program are accessed through keys on the keypad.
Keys labelled Setup, Log On, Info, Manual, Codelog and Set Delta provide access to menus (note that in most cases there are also sub-menus). Three of these keys
are referred to as modes: Setup, Manual and Codelog. Through these modes, specific aspects of the receiver’s functionality can be enabled, disabled or amended.
The keypad is used to enter or select operating parameters, input data and for navigate through menus and pages. Every key, except Light, has two functions.
Which function is accessible depends on the state of the receiver.
The LCD display is a two line display that is used to request input, either in the form of a menu selection or the entry of a numeric value. It is necessary to spread
out the information, therefore the display shows what is referred to as a page, whereby a menu item can link to more than one page. Scroll through pages using
the right and left arrow keys or the END/ESC key.
The LCD display also provides current setting information. This information depends on whether the receiver is Online or Offline.
• If the receiver is Online then the display shows current settings within brackets after the title of a page (e.g. Scan Options) and still allows a new value to be
entered.
• If the receiver is Offline then the display shows current settings after the title of a page, but there is no provision for a new value to be entered.
STARTING THE RECEIVER
After turning on the receiver the sequence of messages on the LCD screen will be similar to the following:
SRX600 BOOT CODE V2.5
LOTEK WIRELESS INC.
SRX600 BOOT CODE V2.5
SYSTEM STARTUP (1) ...
USER: NONE (OFFLINE)
MODE: SETUP
The last page shows if there is a user logged onto the receiver (Online) or not (Offline) and it also displays the mode that the receiver was in (e.g. Setup).
Revision D, #10055, March 16th, 2005
3 of 20
Log On
ILogging on to the receiver provides the ability to change the state of the receiver. When a log on password is provided the receiver is considered
Online. If no password is provided (logged off) then the receiver is Offline. The differences between Online and Offline are described below:
• Offline: the receiver allows only read access, which means that most inputs are not allowed unless a log on password is provided. The only input
allowed is the Reset Password function.
• Online: the receiver allows full write access, which means that all functionality and input capability are available.
Log on to the receiver via Log On > 1)Log On or Log On > 2)Log On via Factory Password. Wait a few seconds for the changes to be accepted and
then the receiver returns to the last state that was active (e.g. scan) or the start page.
The log on password is always 123456 unless it is changed via Setup > 3)Change Password.
Logging on via the factory password provides the ability to log on quickly, as long as the factory password (123456) is being used. This feature is convenient
for people who do not need or want to have a specific confidential password.
Logging on can be done at any time during the operation if the receiver, except while using the Info key and its menu items.
LOGGING OFF
Logging off can be done at any time during the operation of the receiver, which means that data collection can continue while limiting access to settings via a
password. Logging off means the receiver is Offline.
Log off from the receiver via Log On > 2)Log Off or Log On > 3)Temporarily Log Off. Wait a few seconds for the changes to be accepted and then the receiver
returns to the start page (first information shown after receiver turns on).
Temporarily logging off creates a restriction, whereby logging on is only accessible from the keypad and no longer accessible from the SRX Host software, except
via the Host’s Keypad Simulator.
Revision D, #10055, March 16th, 2005
4 of 20
Setup mode
(1): 1)115200
2)57600 3)38400 4)19200 5)9600
6)4800 7) 2400 8)1200 9) 600
SERIAL BAUD RATE
1) Serial I
2) Serial II
##: 1)BAUD RATE
2) PARITY
3) DATA BITS
4) STOP BITS 5)MODEM
SERIAL
1) Baud Rate
2) Parity
CONFIGURE COMM:
1) Configure 1)SERIAL I 2) SERIAL II
SERIAL PARITY(1):
1)NONE 2)ODD 3)EVEN
3) Data Bits
SERIAL DATA BITS(2):
1) 7 BITS 2) 8 BITS
4) Stop Bits
SERIAL STOP BITS(1):
1) 1 BIT 2) 2 BITS
5) Modem
MODEM
1) HAS MODEM
2) VIEW CMDS 3) INITIALIZE
SETUP: 1)COMM 2)TIME
3) RESET/CHANGE PASSWORD
1) COMM
COMM (CYCLE POWER OFF/ON)
1)CONFIGURE 2)FACTORY SETTINGS
1) Has Modem SERIAL I HAS MODEM (9)
7) YES
2) View CMDS
2) Factory Settings
SET TO FACTORY SETTINGS:
(SERIAL, 115200, 8, N, 1)
1) SERIAL I 2) SERIAL II
2) Time - see page 5
3) Reset/Change Password - see page 5
Revision D, #10055, March 16th, 2005
3) Initialize
9) NO
MODEM INIT CMD1:
ATZ0
NO MODEM, PLEASE SELECT
IT VIA ‘SETUP/COMM’
5 of 20
1) GMT Correction
2) Time
TIME (11:24:33 17/06/04):
1)GMT CORRECTION 2)LOCAL DATE
3)LOCAL TIME
2) Local Date
GMT CORRECTION
(-05:00):
(HH:MM) > --
LOCAL DATE (17/06/04):
(DD/MM/YY)>
3) Local Time
RESET PASSWORD (630387):
3) Reset/Change Password (XXXXXX)>
OR
LOCAL TIME (11:24:33):
(24HH:MM:SS)>
CHANGE PASSWORD (******):
(OLD/NEW)>
Revision D, #10055, March 16th, 2005
6 of 20
Manual mode
1) Code Set
MANUAL:
2)SEARCH
CODE SET(1): 1)LOTEK 2
2)LOTEK3
3) LOTEK4
OR
CODE SET: LOTEK 2
1)CODE SET
3)SIGNAL
2) Search ... see page 7
3) Signal ... see page 8
Revision D, #10055, March 16th, 2005
7 of 20
Manual Mode > 2) Search
SEARCH
148.220MHZ ID AH0=40
0) PAUSE SCAN
1) CODE SET
2)SHOW BEEP/ID/SENSOR
3)SET
4)GPS
5) INC. FREQ. 6)DEC. FREQ.
7)EN/DIS NOISE BLANK 8) INC. GAIN
1) Start
SEARCH (FROM 148.516MHZ):
1)START
2)GAIN
3)MIN FREQ 4)MAX FREQ
5)FREQ STEP 6)SCAN TIME
7)NOISE THRESHOLD
2)Gain
3)Min Freq
4)Max Freq
5)Freq Step
6)Scan Time
7)Noise Threshold
0)Pause Scan
9)DEC. GAIN
FOUND:
I184 S121 10:54:21
148.220MHZ CODE GAIN =33
0) PAUSE SCAN 1) CODE SET
2)SHOW BEEP/ID/SENSOR 3)SET DELTA
4)GPS
5) INC. FREQ. 6)DEC. FREQ. 7)EN/DIS NOISE BLANK
8) INC. GAIN 9)DEC. GAIN
GAIN (87):
(00-99) >
MIN FREQ (148.000MHZ):
(148-152.000MHZ) >
MAX FREQ (152.000MHZ):
(148-152.000MHZ) >
FREQ STEP (002KHZ):
(001-999KHZ) >
SCAN TIME (2.2S):
(0.1-9.9SEC) >
NOISE THRESHOLD
(40):
(00-99) >
Revision D, #10055, March 16th, 2005
PAUSE: I999 S102 11:13:46
148.220MHZ
AH0=40
0) RESUME SCAN 1) CODE SET
2)SHOW BEEP/ID/SENSOR
3)SET DELTA 4)GPS
5) INC. FREQ.
6)DEC. FREQ. 7)EN/DIS NOISE BLANK
8) INC. GAIN 9)DEC. GAIN
8 of 20
Manual Mode > 3) Signal
1)START 2)GAIN
3)ANT 4)FREQ 5)NOISE THRESHOLD
1)Start
SIGNL: I999 S102 11:13:46
148.220MHZ ID AH0=40
1) CODE SET
2)SHOW BEEP/ID/SENSOR
3)SET DELTA 4)GPS
5) INC. FREQ. 6)DEC. FREQ.
7)EN/DIS NOISE BLANK
8) INC. GAIN 9)DEC. GAIN
2)Gain
GAIN(87):
(00-99)>
SIGNAL:
3)Ant
ANT(0):
(AH0=0, ASP8=1-8)>
RADIO FREQ(149.010MHZ):
1)Radio (148-152.000MHZ)>
4)Freq
FREQ(149.010MHZ):
1)RADIO 2)ACOUSTIC
2)Acoustic ACOUSTIC FREQ(NONE):
(000-999KHZ)>
5)Noise Threshold
NOISE THRESHOLD(40):
(00-99)>
Revision D, #10055, March 16th, 2005
9 of 20
Codelog Mode
1)Config(#1) ... see page 10
CODELOG: 1)CONFIG# 2)SCAN
3)MASTER FTABLE
2)Scan ... see page 16
3) Master FTable ... see page 17
Revision D, #10055, March 16th, 2005
10 of 20
Codelog Mode > 1)Config#1
NEW CFG#(3):
1)New Cfg# (1-8)>
1)Radio
ADD RADIO FERQ(#11):
(148-152.000MHZ)>
ADD FREQ/CH:
1)Add 1)RADIO 2)ACOUSTIC
1)Config(#1)
CONFIG(#3): 1)NEW CFG#
2)SCAN SETTINGS
3)FREQ/CH 4)ANT/HYDR
5)FILTERS
6)SENSORS
FREQ/CH
2)Acoustic
(10):
3)Freq/CH 1)ADD 2)VIEW/MODIFY
3)VIEW/MODIFY ALL
2)View/Modify
2)View/Modify All
2)Scan Settings ... see page 11
4)Ant/Hydr ... see page 12
5)Filters ... see page 13
6)Sensors ... see page 15
Revision D, #10055, March 16th, 2005
149.891MHZ CH456 EN ID:
1)DEL 2)EN/DIS 3)ID/SEN
ALL FREQ/CH(2, 4): 1)DEL
2)EN 3)DIS 4)ID 5)SEN
ADD ACOUSTIC FREQ(#11)
(000-999KHZ)>
11 of 20
Codelog Mode > 1)Config#1 > 2)Scan Settings
1) Code Set
CODE SET(1): 1)LOTEK2
2)LOTEK3 3)LOTEK4
1) Scan Time
SCAN SETTINGS:
SCAN TIME(18.1S):
(00.1-99.9SEC)>
2)Scan Settings 1)CODE SET 2)PARAM
3)OPTIONS
4)SITE NUMBER
TOTAL SCAN TIME(47:59):
2) Param
3) Options
PARAM:
1)SCAN TIME
2)TOTAL SCAN TIME
SCAN OPTIONS: 1)TOA 2)CRTO
3)AGC 4)GPS
2)Total Scan Time
(MM:SS)>
1) TOA
TOA(2):
1)ENABLE
2) CRTO
3) AGC
4) GPS
4) Site Number
SITE NUMBER(1234):
(0000-9999)>
Revision D, #10055, March 16th, 2005
2)DISABLE
CRTO(2): DIS
1)EN/DIS 2)TIMEOUT
AGC(1):
1)ENABLE
2)DISABLE
GPS: DIS CLK, DIS POS
1)EN/DIS CLK
2)EN/DIS POSITION
12 of 20
Codelog Mode > 1)Config#1 > 4) Ant/Hydr
1)Use ASP8
USE ASP8
1)YES 2)NO
RADIO ANT GRP(123):
(1-8)>
3)Ant
4)Ant/Hydr ANT/HYDR: 1)USE ASP8
2)GAIN 3)ANT 4)HYDR
5) PRIORITY
ANT: 1)RADIO ANT GRP
2)RADIO MASTER ANT
RADIO MASTER ANT(9):
(GRP=0 ASP8=1-8 NO=9)>
HYDR GRP(567):
(1-8)>
4)Hydr
HYDR:1)ACOUSTIC HYDR GRP
2)ACOUSTIC MASTER HYDR
ACOUSTIC MASTER HYDR(0):
(GRP=0 ASP8=1-8 NO=9)>
1)ASP8 Gain
2)Gain
GAIN: 1)ASP8 GAIN
2)AH0 ANT GAIN
3)RADIO MASTER GAIN
4)ACOUSTIC MASTER GAIN
2) AH0 ANT Gain
3)Radio Master Gain
4)Acoustic Master Gain
5)Priority
PRIORITY: FREQ, DIS MPVIEW
1)FREQ/ANT 2)EN/DIS MASTER PREVIEW
Revision D, #10055, March 16th, 2005
ASP8 GAIN (40,21,33,54,22,
36,47,18): PORT #(1-8)>
AH0 ANT GAIN(33):
(00-99)>
RADIO AMG GAIN(40):
(00-99)>
ACOUSTIC
(00-99)>
HM3 GAIN(60):
13 of 20
Codelog Mode > 1)Config#1 > 5)Filters
1) ID Filter
FILTERS:
FILTER: 1)FILTER TYPE
2)SET REJECT CH/ID
3)SET ACCPET CH/ID
4)SET REJECT ID
5)SET ACCEPT ID
1) Filter Type
FILTER TYPE (3): 1)NO FILTER
2)REJECT CH/ID 3)ACCEPT CH/ID
4)REJECT ID 5)ACCEPT ID
1)ID FILTER
1) Add
ADD REJECT CH/ID
(#33):
(XXX/XXX)>
REJECT CH880 ID110
(#20):
ADD ACCEPT CH/ID
(#21):
2) View/Del 1)DEL
5) Filters 2)PULSE FILTER
2) Set Reject CH/Id
SET REJECT CH/ID
(32):
1)ADD 2)VIEW/DEL
1) Add
2) View/Del
3) Set Accept CH/Id
(XXX/XXX)>
ACCEPT CH240 ID211
1)DEL
SET ACCEPT CH/ID (20):
1)ADD 2)VIEW/DEL
(#30):
ADD REJECT ID
1) Add (XXX)>
4) Set Reject Id
SET REJECT ID (29):
1)ADD 2)VIEW/DEL
REJECT ID450
2) View/Del 1)DEL
(10):
1)ADD 2)VIEW/DEL
SET ACCEPT ID
5) Set Accept Id
ADD ACCEPTID
1) Add (XXX)>
2) View/Del
2) Pulse Filter ... see page 14
Revision D, #10055, March 16th, 2005
(#25):
ACCEPT ID211
1)DEL
(#11):
(#03):
(#11):
14 of 20
Codelog Mode > 1)Config#1 > 5)Filters > 2)Pulse Filter
1) Echo
2) Noise Threshold
2) Pulse Filter
ECHO FILTER (020MS):
(000-255)>
NOISE THRESHOLD (30):
(00-99)>
PULSE FILTER: 1)ECHO
2)NOISE THRESHOLD
3)PULSE WIDTH
4)SIGNAL STRENGTH DEV
2.0MS PULSE WIDTH (1):
1)ENABLE 2)DISABLE
MIN
3) Pulse Width
18 SIGNAL S DEV (2):
1)ENABLE 2)DISABLE
MAX
4) Signal Strength Dev
Revision D, #10055, March 16th, 2005
15 of 20
MIN(-0006.0
Codelog Mode > 1)Config#1 > 6)Sensors
1) C
1) Class
C):
>-C[-6.0, 34.0]/50):
1)MIN 2)MAX 3)LEVEL
SENSOR CLASS(0):
(0-9)>
MAX(+0034.0
C):
>+
C LEVEL(050):
(001-255)>
MIN(+0000.0 PSI):
>+
2) psi
2) Type
6) Sensors
SENSORS: 1)CLASS 2)TYPE
3)PARAM
PSI[0.0, 50.0]/51):
1)MIN 2)MAX 3)LEVEL
SENSOR TYPES(123): (1=C
2=PSI 3=ACT 4=EMG)>
MAX(+0050.0 PSI):
>+
PSI LEVEL(050):
(001-255)>
ACT MIN
(0):
3) Param
SENSOR PARAM:
1)C 2)PSI 3)ACT 4)EMG
3) ACT
([0, 1]/2):
1)MIN 2)MAX 3)LEVEL
ACT
ACT MAX
(1):
ACT LEVEL(2):
(1-9)>
MIN(+0000.0 EMG):
>+
4) EMG
EMG ([0.0, 50.0]/51):
1)MIN 2)MAX 3)LEVEL
MAX(+0050.0 EMG):
>+
EMG LEVEL
(001-255)>
Revision D, #10055, March 16th, 2005
(051):
16 of 20
Codelog Mode > 2)Scan
1) Continue to Log Data
SCAN: I243 S100 14:22:33
148.220MHZ CH800 AMG=33
0)PAUSE SCAN 2)VIEW
3)SET DELTA 4)GPS
7)EN/DIS NOISE BLANK
8)INC. GAIN 9)DEC. GAIN
0) Pause Scan
PAUSE: I243 S100 14:22:33
148.220MHZ CH800 AMG=33
0)RESUME SCAN 1)FILTERS
2)VIEW 3)SET DELTA 4)GPS
5)INC. FREQ 6)DEC.FREQ
7)EN/DIS NOISE BLANK
8)INC. GAIN 9)DEC. GAIN
1)Filters ... refer to page 13
TEMP, PRESSURE (C, PSI):
1)C/F
2)PSI/M
2) View
2) Scan
VIEW: 1)DISPLAY SCROLL
2) TEMP, PRESSURE UNITS
DISPLAY SCROLL:
0 OF 64 DETECTION
SCAN(3712 KBYTES FREE):
1)CONTINUE TO LOG DATA
2)DEL ALL DATA (PASSWORD)
DELTA FREQ(001 KHZ):
(001-999)>
3) Set
SET DELTA
: 1)FREQ
2)GAIN
DELTA GAIN(02):
(01-99)>
4) GPS
2)Del All Data (password) DEL ALL DATA (PASSWORD):
(XXXXXX)>
Revision D, #10055, March 16th, 2005
GPS(OFF) : NOT ENABLED
17 of 20
Codelog Mode > 3)Master Ftable
3) Master FTable
1)UUC Freq
UUC FREQ(150.000MHZ):
(148-152.000)>
2) Master F Table
148.000MHZ CH001 #1 IS
IN CFG: #1,2,4
MASTER FTABLE: 1)UUC FREQ
2)VIEW MASTER FTABLE
Revision D, #10055, March 16th, 2005
18 of 20
SET Delta
DELTA FREQ(001 KHZ):
(001-999)>
SET DELTA
: 1)FREQ
2)GAIN
DELTA GAIN(02):
(01-99)>
Revision D, #10055, March 16th, 2005
19 of 20
GPS
Before GPS fix ...
TEST GPS: TIME + POSITION
After GPS fix ...
TEST GPS: 15:34:27 (GMT)
-44.0627687
79.4467891
Other possible message ...
TEST GPS: TIME + POSITION
ANTENNA OPEN DETECTED
Revision D, #10055, March 16th, 2005
20 of 20
Revision D, #10055, March 16th, 2005

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2005:03:16 13:29:58Z
Create Date                     : 2004:08:11 13:51:00Z
Page Count                      : 20
Creation Date                   : 2004:08:11 13:51:00Z
Mod Date                        : 2005:03:16 13:29:58Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Janelle
Metadata Date                   : 2005:03:16 13:29:58Z
Creator                         : Janelle
Title                           : Guide to SRX 600 Keypad and LCD Display Rev D #10055.fm
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools
FCC ID Filing: FW9SRX600

Navigation menu