Lutron Electronics 0056 Electronic dimmer with RF communication User Manual

Lutron Electronics Company Inc Electronic dimmer with RF communication

User Manual

Load SpecificationsControl Load Type Min. LoadMax. LoadSZ-1SDIncandescent 10 W 150 WHalogen 10 W 100 WCompact fluorescent 10 W 30 W Important NotesInstall in accordance with all local and national electrical codes.Environment: Ambient operating temperature: 32 to 104 °F (0 to 40 °C),  0 to 90% humidity, non-condensing. Indoor use only.Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions.RF Device Placement: RF dimmers and switches must be located within 20 feet (6 m) of an RF signal repeater or a device configured as a repeater.Stanza RF dimmers or switches cannot be controlled by the system until they are addressed and programmed. They will work as stand-alone controls only.Range and performance of the Stanza system are dependent on a variety of factors, including:•  Distance between system components•  Geometry of the space•  Construction of walls separating system•  Electrical equipment located near the system components•  Position of the lamp socket dimmer/switch.Lamp requirements: Do not use dimmer to control table lamps with touch control or with integral dimmers. Lamps without integral switches are recommended; lamps with integral switches must be set to full on, then the switch should be disabled or removed.The lamp socket dimmer/switch may be installed in any orientation between vertical and 90° from vertical. When installed in any orientation other than vertical, derating is required.Derating Chart Orientation Load Type RatingVerticalIncandescent 150 WHalogen 100 W10 to 90°  from verticalIncandescent 100 WHalogen 75 W 1.  Find a suitable location for the lamp socket dimmer/switch. The dimmer/switch must be within 20 feet (6 m) of a device congured as a repeater. If there is a switch on the lamp, make sure it is in the full on position, and remove or disable it if possible.2.  Unplug the lamp cord from the wall receptacle.3.  Remove the lamp harp.4.  Remove the lamp bulb, and screw the lamp socket dimmer/switch into the lamp socket. Replace the bulb into the lamp socket dimmer/switch.5.  Reinstall the lamp harp (rotate it to clear the lamp socket dimmer/switch if necessary). If desired, install the optional harp lock using the provided hex wrench.6.  Plug the lamp cord into the wall socket.     Dimming Knob•  Turn clockwise to turn on and brighten•  Turn counter-clockwise to dim and turn off•  Push in to toggle on and off•  Push in and hold to enter program-ming mode•  Audible sound indicates when high and low levels are reached  Status Indicator•  Indicates current load status•  Green = load is switched on•  Off = load is switched off•  Amber = device is in programming mode•  Red = device is experiencing an over-temperature condition  Operation Notes•  The lamp socket dimmer/switch should immediately control the bulb once power is applied.•  When initially installed, the lamp socket dimmer/switch functions only as a switch, which allows it to control non-dimmable compact uorescent bulbs. To also dim incandescent loads, it must rst be addressed as part of a Stanza system.•  The lamp socket dimmer/switch cannot be controlled over radio frequency (RF) from a keypad or contact closure input until it has been addressed as part of a Stanza system.   Returning the Dimmer/Switch to  Factory Settings1.  Triple-tap the dimming knob quickly (within 1 second).2.  Press and hold the dimming knob for 5 seconds (until the load ashes).3.  Triple-tap the dimming knob quickly again. Notes•  Returning to factory settings will clear all programming from the lamp socket dimmer/switch device, and will prevent it from being controlled over RF from a keypad or control interface.•  After being returned to factory defaults, the device will need to be re-addressed as part of a system.•  The device will revert to switching operation, so non-dimmed compact uorescent loads can be controlled. Incandescent loads then cannot be controlled until the device has been re-addressed as part of a system. Otherwise, damage to the device or bulb may occur.Installation InstructionsPlease Read Before InstallingLamp Socket Dimmer/SwitchStanzaTMStanzaTM Lamp Socket  Dimmer/SwitchSZ-1SD-TP120 V   50 / 60 HzInstallation OperationRemove lamp harp.Install lamp socket.Tighten harp lock.Caution! To avoid risk of elec-trical shock, do not attempt to open the lamp socket dimmer / switch. Unplug the table lamp before changing the light bulb.Lutron Electronics Co., Inc.Made and printed in the U.S.A.P/N 030-996 Rev. A 6 /08Technical support:  USA, Canada, Caribbean: 1.800.523.9466 Mexico: +1.888.235.2910 Central/South America: +1.610.282.6701Warranty: 1-year limited warranty standard. 2-year parts and labor warranty, with 8-year pro-rated parts replacement on commissioned systems.These products may be covered under one or more of the following U.S. patents: 5,248,919; 5,838,226; 5,848,054; 5,905,442; 6,687,487; 6,803,728; and corresponding foreign patents. U.S. and foreign patents pending. Lutron and the sunburst logo are registered trademarks and Stanza is a trademark of Lutron Electronics Co., Inc.© 2008 Lutron Electronics Co., Inc.RDimming knobStatus indicatorTroubleshooting GuideSymptom Cause and ActionLight does not turn on, but the status indicator is on.Light bulb/lamp is burned out or not installed.•   Replace or install lamps.Light does not turn on, and the sta-tus indicator is off.Power is off•   Check the circuit breaker and make sure it is on.Lamp is unplugged•  Check that the lamp cord is plugged into the wall socket.Lamp has an integral switch•  Make sure the lamp’s integral switch is set to full on.Dimmer does not dim properly and/or flick-ers.Lamp has an integral dimmer•  Use a lamp without a dimmer.Bulb is not dimmable•  Replace bulb with incandescent bulb.FCC InformationNote: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules. Operation is subject to the following: (1) This device may not cause harmul interference, and (2) this device must accept any interference received, incouding interference that may cause undesired operation.

Navigation menu