Lutron Electronics 0062 Dimmer or Switch User Manual 6

Lutron Electronics Company Inc Dimmer or Switch 6

User Manual 6

Designer-Style RF Maestro®  Dimmers: SRD-6D, SRD-10D, SRD-10NDSwitch: SRD-8ANSFan Speed Control: SRD-2ANFRemote Dimmer: SD-RDRemote Switch: SD-RS120 V   50 / 60 HzInstallation InstructionsPlease Read Before InstallingMultigang InstallationsIn multigang installations, several controls are grouped horizontally in one multigang wallbox.When combining controls in a wallbox, derating is required; however, no derat-ing is required for Fan Speed or Remote Dimmers  / Switches.Derating Chart Control Load Type End of Gang Middle of GangSRD-6DIncand. 500 W 400 WMLV 400 W /  500 VA 300 W /  400 VASRD-10D, SRD-10NDIncand. 800 W 650 WMLV 600 W /  800 VA 500 W /  650 VASRD-8ANSLighting 6.5 A 5 AMotor 1/4 HP 5.8 A 1/6 HP 4.4 A Note: -8ANS controls have fins that need to be removed for multigang installations.  -6D, -10D, -10ND, -2ANF, -RD and -RS controls do not have fins that need to be removed for multigang installations.Short Circuit Check: Check the instal-lation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights or fan do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit.1.  Turn power OFF at fusebox or circuit breaker.2.  Prepare wires. When making wire con-nections, follow the recommended strip lengths and combinations for the sup-plied wire connector. Note: Wire con-nector provided is suitable for copper wire only.Multi-Location Installation2-6D, -10D with SD-RDWiring Diagram 3Single Location Installation with Neutral-10ND, -8ANS, -2ANF120 V   50 / 60 HzBrassSilverBlackBlue Tighten1GreenGroundHot/LiveNeutralLoadWiring Diagram 2Single Location Installation-6D, -10DWiring Diagram 1Multi-Location Installation with Neutral2, 3 -10ND, SD-RD, -2ANF -8ANS with SD-RSDimmer / Switch / Fan Speed Control3  Neutral wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation.2  Up to 9 RadioRA-SR Remote Dimmers / Switches may be connected to the RadioRA-SR Dimmer / Switch. Total blue terminal wire length may be up to 250 ft (76 m).1  When using controls in single location installations, tighten the blue terminal.  DO NOT connect the blue terminal to any other wiring or to ground.Status LEDs (Dimmer / Fan Speed Only)Indicate light / speed level; glow  softly as night light when load is offTapswitchTap on/offDimming RockerPress to Brighten / Increase SpeedPress to Dim / Decrease SpeedFASSTMFrontAccessibleServiceSwitchDimmer / Fan Operation Switch OperationLamp Replacement   WARNING - For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or even death.   For routine lamp replacement, remove power from the fixture(s) by pulling the FASS switch out on both the Dimmer / Switch and all Remote Dimmers / Switches.Troubleshooting GuideLutron Elec tron ics Co., Inc. 7200 Suter RoadCoopersburg, PA 18036-1299Made and print ed in the U.S.A.  5 / 09   P/N 044-148 Rev. BMounting DiagramControl Mounting ScrewsWallboxControlIncluded:Wire Connector (1)Mounting Screws (2)Adapter Mounting ScrewsWallplate adapter and wall-plate purchased separately.DimmerStatus LED (Switch Only)Indicates light status; glows softly as night light when light is offTapswitchTap on/offFASSFrontAccessibleServiceSwitchBrassBlackBlue Tighten1GreenGroundHot/LiveNeutralLighting LoadDimmerBrassBlackBlueGreenGroundLighting LoadDimmerBrassBlackBlueGreenGroundRemote Dimmer120 V   50 / 60 HzBrassBlackBlueGreenGroundHot/LiveNeutralRemote DimmerBrassSilverBlackBlueGreenGroundLoadBrassBlackBlueGreenGroundRemote Dimmer/Switch120 V   50 / 60 HzBrassBlackBlueGreenGroundHot/LiveNeutralRemote Dimmer/SwitchPush-In Terminals: Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in ter-minal. Push screwdriver in while pulling wire out. Push-in terminals are for use with 14 AWG (1.5 mm2) solid cop-per wire only. DO NOT use stranded or twisted wire.  ORScrew Terminals: Wrap wire around screw terminal. Tighten securely to 5 in-lbs (0.55 N•m). Screw terminals are for use with solid cop-per wire only. DO NOT use stranded or twisted wire.Trim or strip wallbox wires to the length indi-cated by the strip gauge on the back of the control.   Wire Connector: •  Strip insulation 3/8 in (10 mm) for 14 AWG or 12 AWG (1.0 mm2 or 2.5 mm2) wire•  Strip insulation 7/16 in  (11 mm) for 18 AWG (0.75 mm2) wire•  Use to join one or two 14 AWG   or 12 AWG (1.5 mm2  or  2.5 mm2) wires with one  18 AWG (0.75 mm2) control wire.Twist wire  connector tight.Removing Fins on -8ANSEach control has inside fins removedControl at middle of Gang has all fins removedDo Not remove outside fins on Controls at the end of gangControl Location for GangingInstallationWARNING - To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death.Dimmer / SwitchWiring Diagram 4Switch Fan Speed Control120 V   50 / 60 Hz3.  Wire controls as follows: Single location installation: See Wiring Diagrams 1 and 2. Multi-location installation: See Wiring Diagrams 3 and 4.4.  Push all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws pro-vided. Do not pinch the wires.5.  Attach Lutron Claro or Satin Colors wall-plate adapter and wallplate.   a.  Install wallplate adapter onto front of control(s).  b.  Tighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten).  c.  Snap wallplate onto wallplate adapter, and verify that control is aligned prop-erly.  d.  If control(s) is(are) misaligned, loosen mounting screws appropriately. 6.  Restore power. Check for correct local operation (see Dimmer / Fan Operation and Switch Operation).Symptom Probable Cause and ActionNo lights at all or no fan responsePower not present   •  Circuit breaker OFF or tripped. Perform Short Circuit Check.   •  FASS is in the OFF position. Move FASS to the ON posi-tion by fully pushing it in. Check both the Dimmer / Fan Control / Switch and all of the Remote Dimmers / Switches.Wiring   •  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires.   •   Wiring error. Check wiring to be sure it agrees with installa-tion instructions and wiring diagrams.Lamps burned out or not installed   •   Replace or install lamps.Dioded lamps   •   If dioded lamps are being used, replace with non-dioded lamps.Fan setting   •  Make sure the fan is set to its highest speed using the pull-chain.Fan Speed Control Wrong Load Type   •  Make sure that only a single ceiling paddle fan (permanent split-capacitor motor) rated at 2 A or less is connected to the control.   •  Make sure that no lighting load (i.e. light kit) is connected to the control.Lights / fan turn ON when Tapswitch is pressed, then turn OFFWiring   •   Wiring error. Check wiring to be sure it agrees with installa-tion instructions and wiring diagrams.Tapswitch stuck   •  Tapswitch stuck at another location. Check to see that tapswitches are not sticking for all control locations in the circuit.Light turns ON and OFF continuouslyLoad is less than minimum load requirement   •  Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications.Lights / fan don’t switch ON / OFF when Tapswitch on Dimmer / Switch / Fan Speed Control/  Remote is pressedWiring   •  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires.   •   Wiring error. Check wiring to be sure it agrees with installa-tion instructions and wiring diagrams.   •  Neutral-based product installation location. Check that neutral-based products are connected on the load side of a multi-location installation (see Wiring Diagram 4).Lights / fan don’t switch ON/OFF from KeypadImproper programming   •  Program according to the RadioRA-SR Setup Guide.Out of RF range   •  Reposition to be within 30 feet (9 m) of controling keypad.Wiring   •  Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires.   •   Wiring error. Check wiring to be sure it agrees with installa-tion instructions and wiring diagrams.Wallplate is warm Solid-state control dissipation   •  Solid-state dimmers, switches, and fan controls internally dissipate about 2% of the total connected load. It is normal for dimmers, switches, and fan controls to feel warm to the touch during operation.Control is buzzing or hummingIt is normal for dimmers, switches, and fan controls to emit a slight buzzing or humming sound.For Installation Guides, System Setup Guide and Setup tools visit http://www.lutron.com/radiorasr. Load Specifications:Control Load Type Min. Load Max. LoadSRD-6D1Incand. 50 W 600 WMLV250 W / VA 450 W /  600 VASRD-10D1Incand. 50 W 1000 WMLV250 W / VA 800 W /  1000 VASRD-10ND1Incand. 10 W 1000 WMLV210 W / VA 800 W /  1000 VASRD-8ANS3Lighting 10 W / VA 8 AMotor 0.083 A 1/4 HP  5.8 ASRD-2ANF4Ceiling Fan 0.083 A 2 ASD-RD See Dimmer/Fan Speed Control 8.3 ASD-RS See Switch 8.3 A 1  Dimmer Load Type: -6D, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tung-sten halogen only. Do not install dimmers to control receptacles or motor-operated appli-ances. 2  Low-Voltage Applications: Use -6D, -10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit with lamps inoperative or removed may result in trans-former overheating and premature failure. Lutron strongly recommends the following:  •  Do not operate low-voltage circuits without operative lamps in place.  •  Replace burned-out lamps as quickly as possible.  •  Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent.3  Switch Load Type: -8ANS is designed for use with permanently installed incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A).4  Ceiling Fan Application (SRD-2ANF):  DO:  •  Use to control one paddle-type ceiling fan (permanent split-capacitor).   •  Use the ceiling fan’s pull chain to set its speed to the highest setting.    DO NOT:   •  Do not use to control fans that use shaded-pole motors (i.e. bath exhaust fans).  •  Do not use to control fans that have inte-grated fan speed controls (i.e. fans that have a remote control), unless the integrated con-trol is removed from the ceiling fan.  •  Do not connect to any other motor-operated appliance or to any lighting load type.  •  Do not use to control a fan lighting load (i.e. light kit).Technical Assistance: USA / CAN: 1.800.523.9466 Mexico: +1.888.235.2910 Other Countries: +1.610.282.3800  24 hours a day, 7 days a week.Important NotesWARNING - To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equip-ment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death.Codes: Install in accordance with all local and national electrical codes.Grounding: When no “grounding means” exist within the wallbox, then the NEC® 2008, Article 404-9 allows a dimmer with-out a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the dimmer and use an appropriate wallplate such as Lutron’s Claro® or Satin Colors® wallplates. Neutral Wire: -10ND, -8ANS, and -2ANF require a neutral wire connection in the wallbox where the Dimmer/Switch / Fan Speed Control is to be installed. If a neu-tral wire connection is not available in the wallbox, contact a licensed electrician for installation. Environment: Ambient operating tempera-ture: 32 °F to 104 °F (0 °C to 40 °C),  0% to 90% humidity, non-condensing. Indoor use only.Spacing: If mounting one control above another, leave at least 4 1⁄2 in (114 mm) ver-tical space between them.Wallplates: Lutron® Claro and Satin Colors wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates.Cleaning: To clean, wipe with a clean damp cloth. DO NOT use any chemical cleaning solutions.Wallboxes: Lutron recommends using 31⁄2 in (89 mm) deep wallboxes for eas-ier installation. Several controls may be installed in one multigang wallbox — see Derating Chart.Remote Dimmers / Switches: Use only Lutron RadioRA®-SR Maestro Remote Dimmers (-RD) with -6D, -10D, -10ND,  and -2ANF controls. Use only Lutron RadioRA-SR Maestro Remote Switches (-RS) with -8ANS controls. Up to 9 -RD or -RS controls may be used with a RadioRA-SR Maestro Dimmer, Switch, or Fan Speed Control. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF Dimmers, Switches, and Fan Speed Controls must be located within 30 feet (9 m) of con-trolling keypads. Remote Dimmers and Switches are not required to be within a specific range of controlling keypads.RF Dimmers, Switches or Fan Speed Controls cannot be controlled by the system until they are programmed in a RadioRA-SR system according to the RadioRA-SR Setup Guide.EnglishRemote DimmerRemote SwitchThese products may be covered under one or more of the following U.S. patents: 4,992,709; 5,248,919; 5,399,940; 5,637,930; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,169,377; 6,687,487; 6,803,728; 7,071,634; 7,166,970; 7,362, 285; 7,365,282; 7,382,100; 7,408,525 and corresponding foreign patents. U.S. and foreign patents pending. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, Maestro, RadioRA and the sunburst logo are regis-tered trademarks and FASS is a trademark of Lutron Electronics Co., Inc.   ©2009 Lutron Electronics Co., Inc.Wallplate Adapter WallplateReturning Devices to Factory SettingsNote: Returning a control to its Factory Settings will remove the control from the system and erase all programming.Step 1 :  Triple tap the main button on the control. DO NOT release after the third tap.Step 2 :  Keep the button pressed on the third tap (for approximately 3 seconds) until the status LEDs start to scroll up and down quickly.Step 3 :  Release the button and immediately triple tap the button again. The status LEDs will scroll up and down slowly.The control has now been returned to Factory Settings.Warranty: For Warranty information, please see the enclosed Warranty,  or visit www.lutron.com/resiinfo.

Navigation menu