Lutron Electronics 0062 Dimmer or Switch User Manual 6
Lutron Electronics Company Inc Dimmer or Switch 6
Contents
User Manual 6
English Multigang Installations Designer-Style RF Maestro® Dimmers: SRD-6D, SRD-10D, SRD-10ND Switch: SRD-8ANS Fan Speed Control: SRD-2ANF Remote Dimmer: SD-RD Remote Switch: SD-RS Installation Instructions Please Read Before Installing 120 V 50 / 60 Hz Important Notes Dimmer Switch Fan Speed Control Remote Dimmer Remote Switch For Installation Guides, System Setup Guide and Setup tools visit http://www.lutron.com/radiorasr. Load Specifications: Control SRD-6D1 Load Type Min. Load Max. Load Incand. 50 W 600 W 50 W / VA 450 W / 600 VA MLV Incand. SRD-10D1 SRD-8ANS3 MLV 50 W / VA Incand. 10 W 1000 W MLV2 10 W / VA 800 W / 1000 VA Lighting 10 W / VA 8A 0.083 A 1/4 HP 5.8 A Motor SRD-2ANF Ceiling Fan SD-RD See Dimmer/Fan Speed Control SD-RS 1000 W 800 W / 1000 VA SRD-10ND1 50 W 0.083 A See Switch 2A 8.3 A 8.3 A 1D immer Load Type: -6D, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. 2 Low-Voltage Applications: Use -6D, -10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: •D o not operate low-voltage circuits without operative lamps in place. •R eplace burned-out lamps as quickly as possible. •U se transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Switch Load Type: -8ANS is designed for use with permanently installed incandescent, magnetic low-voltage, electronic low-voltage, or fluorescent loads and with motor loads up to 1/4 HP (5.8 A). 4 Ceiling Fan Application (SRD-2ANF): DO: •U se to control one paddle-type ceiling fan (permanent split-capacitor). • Use the ceiling fan’s pull chain to set its speed to the highest setting. DO NOT: • Do not use to control fans that use shadedpole motors (i.e. bath exhaust fans). • Do not use to control fans that have integrated fan speed controls (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan. • Do not connect to any other motor-operated appliance or to any lighting load type. • Do not use to control a fan lighting load (i.e. light kit). Technical Assistance: USA / CAN: 1.800.523.9466 Mexico: +1.888.235.2910 Other Countries: +1.610.282.3800 24 hours a day, 7 days a week. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 5 / 09 P/N 044-148 Rev. B WARNING - To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment which is not visible from every control location or which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Codes: Install in accordance with all local and national electrical codes. Grounding: When no “grounding means” exist within the wallbox, then the NEC® 2008, Article 404-9 allows a dimmer without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the dimmer and use an appropriate wallplate such as Lutron’s Claro® or Satin Colors® wallplates. Neutral Wire: -10ND, -8ANS, and -2ANF require a neutral wire connection in the wallbox where the Dimmer/Switch / Fan Speed Control is to be installed. If a neutral wire connection is not available in the wallbox, contact a licensed electrician for installation. Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. Spacing: If mounting one control above another, leave at least 4 1⁄2 in (114 mm) vertical space between them. Wallplates: Lutron® Claro and Satin Colors wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates. Cleaning: To clean, wipe with a clean damp cloth. Do not use any chemical cleaning solutions. Wallboxes: Lutron recommends using 31⁄2 in (89 mm) deep wallboxes for easier installation. Several controls may be installed in one multigang wallbox — see Derating Chart. Remote Dimmers / Switches: Use only Lutron RadioRA®-SR Maestro Remote Dimmers (-RD) with -6D, -10D, -10ND, and -2ANF controls. Use only Lutron RadioRA-SR Maestro Remote Switches (-RS) with -8ANS controls. Up to 9 -RD or -RS controls may be used with a RadioRASR Maestro Dimmer, Switch, or Fan Speed Control. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF Dimmers, Switches, and Fan Speed Controls must be located within 30 feet (9 m) of controlling keypads. Remote Dimmers and Switches are not required to be within a specific range of controlling keypads. RF Dimmers, Switches or Fan Speed Controls cannot be controlled by the system until they are programmed in a RadioRA-SR system according to the RadioRA-SR Setup Guide. In multigang installations, several controls are grouped horizontally in one multigang wallbox. Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control. When combining controls in a wallbox, derating is required; however, no derating is required for Fan Speed or Remote Dimmers / Switches. Derating Chart Push-In Terminals: Insert wires fully. To release wire, insert small, flat screwdriver into slot below push-in terminal. Push screwdriver in while pulling wire out. Push-in terminals are for use with 14 AWG (1.5 mm2) solid copper wire only. DO NOT use stranded or twisted wire. OR Screw Terminals: Wrap wire around screw terminal. Tighten securely to 5 in-lbs (0.55 N•m). Screw terminals are for use with solid copper wire only. DO NOT use stranded or twisted wire. Control SRD-6D SRD-10D, SRD-10ND SRD-8ANS Load Type End of Gang Middle of Gang Incand. 500 W 400 W MLV 400 W / 500 VA 300 W / 400 VA Incand. 800 W 650 W MLV 600 W / 800 VA 500 W / 650 VA Lighting 6.5 A 5A Motor 1/4 HP 5.8 A 1/6 HP 4.4 A Note: -8ANS controls have fins that need to be removed for multigang installations. -6D, -10D, -10ND, -2ANF, -RD and -RS controls do not have fins that need to be removed for multigang installations. Removing Fins on -8ANS Do Not remove outside fins on Controls at the end of gang Control at middle of Gang has all fins removed Installation WARNING - To avoid the risk of electric shock locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON could result in serious injury or death. Short Circuit Check: Check the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights or fan do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit. 1. T urn power OFF at fusebox or circuit breaker. 2. P repare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector. Note: Wire connector provided is suitable for copper wire only. Wire Connector: • Strip insulation 3/8 in (10 mm) for 14 AWG or 12 AWG (1.0 mm2 or 2.5 mm2) wire • Strip insulation 7/16 in (11 mm) for 18 AWG (0.75 mm2) wire • Use to join one or two 14 AWG Twist wire or 12 AWG (1.5 mm2 or connector 2.5 mm2) wires with one tight. 18 AWG (0.75 mm2) control wire. Single Location Installation with Neutral -10ND, -8ANS, -2ANF Brass Black Brass Silver Ground Probable Cause and Action No lights at all or no fan response Power not present • Circuit breaker OFF or tripped. Perform Short Circuit Check. • FASS is in the OFF position. Move FASS to the ON position by fully pushing it in. Check both the Dimmer / Fan Control / Switch and all of the Remote Dimmers / Switches. Blue Tighten1 Black Lighting Load Symptom Green 120 V 50 / 60 Hz Load Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Ground Neutral Wiring Diagram 3 Lamps burned out or not installed • Replace or install lamps. Multi-Location Installation2 -6D, -10D with SD-RD Remote Dimmer Brass Remote Dimmer Blue Brass Blue Dioded lamps • If dioded lamps are being used, replace with non-dioded lamps. Dimmer Brass Fan setting • Make sure the fan is set to its highest speed using the pullchain. Blue Hot/Live Black c. S nap wallplate onto wallplate adapter, and verify that control is aligned properly. d. If control(s) is(are) misaligned, loosen mounting screws appropriately. 6. R estore power. Check for correct local operation (see Dimmer / Fan Operation and Switch Operation). Mounting Diagram Black Green 120 V 50 / 60 Hz Ground Green Black Green Ground Lighting Load Wiring Diagram 4 Multi-Location Installation with Neutral2, 3 -10ND, SD-RD, -2ANF -8ANS with SD-RS Remote Dimmer/Switch Brass Remote Dimmer/Switch Blue Brass Blue Hot/Live Black Green 120 V 50 / 60 Hz Black Ground Green Dimmer / Switch Brass Silver Black Green Ground Load Wallbox Wire Connector (1) Wallplate Adapter Wallplate Mounting Screws (2) Wallplate adapter and wallplate purchased separately. 1W hen using controls in single location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to ground. 2U p to 9 RadioRA-SR Remote Dimmers / Switches may be connected to the RadioRA-SR Dimmer / Switch. Total blue terminal wire length may be up to 250 ft (76 m). Light turns ON and OFF continuously Load is less than minimum load requirement • Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications. Lights / fan don’t switch ON / OFF when Tapswitch on Dimmer / Switch / Fan Speed Control/ Remote is pressed Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. • Neutral-based product installation location. Check that neutral-based products are connected on the load side of a multi-location installation (see Wiring Diagram 4). Lights / fan don’t switch ON/OFF from Keypad Improper programming • Program according to the RadioRA-SR Setup Guide. Switch Operation Status LEDs (Dimmer / Fan Speed Only) Indicate light / speed level; glow softly as night light when load is off Tapswitch Tap on/off Status LED (Switch Only) Indicates light status; glows softly as night light when light is off Dimming Rocker Press to Brighten / Increase Speed Press to Dim / Decrease Speed Tapswitch Tap on/off FASSTM Front Accessible Service Switch Wiring • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Ground Neutral Dimmer / Fan Operation Lights / fan turn ON when Tapswitch is pressed, then turn OFF Blue 3N eutral wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation. Adapter Mounting Screws Fan Speed Control Wrong Load Type • Make sure that only a single ceiling paddle fan (permanent split-capacitor motor) rated at 2 A or less is connected to the control. • Make sure that no lighting load (i.e. light kit) is connected to the control. Ground Neutral a. Install wallplate adapter onto front of control(s). Control Green Hot/Live Neutral 5. A ttach Lutron Claro or Satin Colors wallplate adapter and wallplate. Included: Tighten1 120 V 50 / 60 Hz 3. W ire controls as follows: Single location installation: See Wiring Diagrams 1 and 2. Multi-location installation: See Wiring Diagrams 3 and 4. Control Mounting Screws Dimmer / Switch / Fan Speed Control Blue Hot/Live b. T ighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten). Each control has inside fins removed Wiring Diagram 2 Single Location Installation -6D, -10D Dimmer 4. P ush all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires. Control Location for Ganging Troubleshooting Guide Wiring Diagram 1 FASS Front Accessible Service Switch Lamp Replacement WARNING - For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON could result in serious injury or even death. For routine lamp replacement, remove power from the fixture(s) by pulling the FASS switch out on both the Dimmer / Switch and all Remote Dimmers / Switches. These products may be covered under one or more of the following U.S. patents: 4,992,709; 5,248,919; 5,399,940; 5,637,930; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,169,377; 6,687,487; 6,803,728; 7,071,634; 7,166,970; 7,362, 285; 7,365,282; 7,382,100; 7,408,525 and corresponding foreign patents. U.S. and foreign patents pending. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, Maestro, RadioRA and the sunburst logo are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. ©2009 Lutron Electronics Co., Inc. Tapswitch stuck • Tapswitch stuck at another location. Check to see that tapswitches are not sticking for all control locations in the circuit. Out of RF range • Reposition to be within 30 feet (9 m) of controling keypad. Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Wallplate is warm Solid-state control dissipation • Solid-state dimmers, switches, and fan controls internally dissipate about 2% of the total connected load. It is normal for dimmers, switches, and fan controls to feel warm to the touch during operation. Control is buzzing or humming It is normal for dimmers, switches, and fan controls to emit a slight buzzing or humming sound. Returning Devices to Factory Settings Note: Returning a control to its Factory Settings will remove the control from the system and erase all programming. Step 1 : Triple tap the main button on the control. DO NOT release after the third tap. Step 2 : Keep the button pressed on the third tap (for approximately 3 seconds) until the status LEDs start to scroll up and down quickly. Step 3 : Release the button and immediately triple tap the button again. The status LEDs will scroll up and down slowly. The control has now been returned to Factory Settings. Warranty: For Warranty information, please see the enclosed Warranty, or visit www.lutron.com/resiinfo.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-702 Instance ID : uuid:89b6a332-80c1-4a2c-92cc-8566b7aed5b2 Document ID : adobe:docid:indd:c99fca8a-3e28-11de-84cd-cd0d1f4bf3a3 Rendition Class : proof:pdf Derived From Instance ID : c99fca89-3e28-11de-84cd-cd0d1f4bf3a3 Derived From Document ID : adobe:docid:indd:c99fca88-3e28-11de-84cd-cd0d1f4bf3a3 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:A430CC26C809DE119918ED6F7D38F888, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:8A466DE623D5DA118F56D14712628810, uuid:7948D9F7C4EBDD11AFD7F93E08A33F11, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:A430CC26C809DE119918ED6F7D38F888, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:7948D9F7C4EBDD11AFD7F93E08A33F11, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:A430CC26C809DE119918ED6F7D38F888, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:7948D9F7C4EBDD11AFD7F93E08A33F11, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:A430CC26C809DE119918ED6F7D38F888, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:7948D9F7C4EBDD11AFD7F93E08A33F11, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E Manifest Reference Document ID : uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:7DB556BA5AE9DD119221F834B0E098EA, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:89466DE623D5DA118F56D14712628810, uuid:7748D9F7C4EBDD11AFD7F93E08A33F11, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:7DB556BA5AE9DD119221F834B0E098EA, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:7748D9F7C4EBDD11AFD7F93E08A33F11, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:7DB556BA5AE9DD119221F834B0E098EA, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:7748D9F7C4EBDD11AFD7F93E08A33F11, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:7DB556BA5AE9DD119221F834B0E098EA, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:7748D9F7C4EBDD11AFD7F93E08A33F11, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E Create Date : 2009:05:14 11:28:16-04:00 Modify Date : 2009:09:25 08:11:56-04:00 Metadata Date : 2009:09:25 08:11:56-04:00 Creator Tool : Adobe InDesign CS3 (5.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 13980 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Has XFA : No Page Count : 1 Creator : Adobe InDesign CS3 (5.0.4)EXIF Metadata provided by EXIF.tools