Lutron Electronics 0062 Dimmer or Switch User Manual 5
Lutron Electronics Company Inc Dimmer or Switch 5
Contents
User Manual 5
English Español Designer-Style RF Maestro® Dimmers HRD-6D, HRD-6ND, HRD-10D, HRD-10ND Switch HRD-8ANS Fan Speed Control Installation Instructions HRD-2ANF Please Read Before Installing 120 V 50 / 60 Hz Important Notes Dimmer Switch Fan Speed Control Load Specifications: Control HRD-6D1 HRD-10D1 HRD-6ND1 HRD-10ND1 HRD-8ANS3 HRD-2ANF Load Type Min. Load Max. Load Incand. 50 W 600 W MLV2 50 W / VA 450 W / 600 VA Incand. 50 W 1000 W MLV2 50 W / VA 800 W / 1000 VA Incand. 10 W 600 W MLV2 10 W / VA 450 W / 600 VA Incand. 10 W 1000 W 10 W / VA 800 W / 1000 VA MLV Lighting 10 W / VA 8A Motor 0.083 A 1/4 HP 5.8 A Ceiling Fan 0.083 A 2A 1D immer Load Type: -6D, -6ND, -10D and -10ND are designed for use with permanently installed incandescent, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to control receptacles or motor-operated appliances. 2 Low-Voltage Applications: Use -6D, -6ND, -10D and -10ND with magnetic (core and coil) low-voltage transformers only. Not for use with electronic (solid-state) low-voltage transformers. To control electronic low-voltage transformers, use the HRD-5NE control. Operation of a low-voltage circuit with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following: •D o not operate low-voltage circuits without operative lamps in place. •R eplace burned-out lamps as quickly as possible. •U se transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to overcurrent. 3 Switch Load Type: -8ANS is designed for use with all permanently installed lighting loads and with motor loads up to 1/4 HP (5.8 A). 4 Ceiling Fan Application (HRD-2ANF): DO: •U se to control one paddle-type ceiling fan (permanent split-capacitor)*. • Use the ceiling fan’s pull chain to set its speed to the highest setting*. DO NOT: • Do not use to control fans that use shadedpole motors (i.e. bath exhaust fans)*. • Do not use to control fans that have integrated fan speed controls (i.e. fans that have a remote control), unless the integrated control is removed from the ceiling fan*. • Do not connect to any other motor-operated appliance or to any lighting load type. • Do not use to control a fan lighting load (i.e. light kit). Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 Made and printed in the U.S.A. 1 / 08 P/N 043-238 Rev. B Codes: Install in accordance with all local and national electrical codes. WARNING - These controls must not be used to control equipment which is not visible from every control location. They must also not be used to control equipment which could create hazardous situations such as entrapment if operated accidentally. Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only. Spacing: If mounting one control above another, leave at least 4 1⁄2 in. (114 mm) vertical space between them. Wallplates: Lutron Claro® and Satin Colors® wallplates are recommended for best color match and aesthetic appearance. Do not paint controls or wallplates. Cleaning: To clean, wipe with a clean damp cloth. Do not use any chemical cleaning solutions. Wallboxes: Lutron recommends using 31⁄2 in. (89 mm) deep wallboxes for easier installation. Several controls may be installed in one multigang wallbox — see Derating Chart. Remotes: Use only Lutron HomeWorks Maestro Remote Dimmers (HD-RD) with -6D, -6ND, -10D, -10ND, and -2ANF controls. Use only Lutron HomeWorks Maestro Remote Switches (HD-RS) with -8ANS controls. Up to 9 HD-RD or HD-RS controls may be used with a HomeWorks RF Maestro Dimmer, Switch, or Fan Speed Control. Mechanical 3- or 4-way switches will not work. RF Device Placement: RF Dimmers, Switches, and Fan Speed Controls must be located within 30 feet (9 m) of an RF Signal Repeater or an RF Processor. Remote Dimmers and Switches are not required to be within a specific range of a repeater or processor. RF Dimmers, Switches or Fan Speed Controls cannot be controlled by the system until they are addressed and programmed. See the HomeWorks Software online help. Français Português Multigang Installations In multigang installations, several controls are grouped horizontally in one multigang wallbox. Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control. When combining controls in a wallbox, derating is required; however, no derating is required for Fan Speed Controls or Remotes. Derating Chart Push-In Terminals: Insert wires fully. Push-in terminals are for use with 14 AWG (1.5 mm2) solid copper wire only. DO NOT use stranded or twisted wire. OR Screw Terminals: Tighten securely to 5 in-lbs (0.55 N•m). Screw terminals are for use with solid copper wire only. DO NOT use stranded or twisted wire. Control HRD-6D, HRD-6ND HRD-10D, HRD-10ND HRD-8ANS HRD-2ANF Load Type End of Gang Middle of Gang Incand. 500 W 400 W MLV 400 W / 500 VA 300 W / 400 VA Incand. 800 W 650 W MLV 600 W / 800 VA 500 W / 650 VA Lighting 6.5 A 5A Motor 5.8 A 5A Ceiling Fan 2A 2A Note: -8ANS controls have fins that need to be removed for multigang installations. -6D, -6ND, -10D, -10ND, and -2ANF controls do not have fins that need to be removed for multigang installations. Removing Fins Control Location for Ganging Do Not remove outside fins on End of Gang Controls 3. W ire controls as follows: Single location installation: See Wiring Diagrams 1 and 2. Multi-location installation: See Wiring Diagrams 3 and 4. Power Booster and Interfaces: When using power boosters or interfaces, see Wiring Diagrams in the HomeWorks Technical Reference Guide (P/N 366963). 4. P ush all wires back into the wallbox and loosely fasten the control to the wallbox using the control mounting screws provided. Do not pinch the wires. 5. A ttach Lutron Claro or Satin Colors wallplate adapter and wallplate. Each control has inside fins removed Middle of Gang Control has all fins removed Installation WARNING - Locate and remove fuse or lock circuit breaker in the OFF position before proceeding. Wiring with power ON may result in personal injury or death. Short Circuit Check: Check the installation for short circuits before installing control(s). With power OFF, install standard mechanical switch(es) between Hot and load. Restore power. If lights or fan do not work or a breaker trips, check wiring. Correct wiring and check again. Install control(s) only when short is no longer present. Warranty is void if control is turned ON with a shorted circuit. c. S nap wallplate onto wallplate adapter, and verify that control is aligned properly. d. If control(s) is(are) misaligned, loosen mounting screws appropriately. 6. R estore power. Check for correct local operation (see Dimmer / Fan Operation and Switch Operation). Single Location Installation with Neutral -6ND, -10ND, -2ANF, -8ANS Control Mounting Screws Wallplate Adapter Mounting Screws Dimmer/Switch Brass Blue Tighten1 Hot/Live Black Green 120 V 50 / 60 Hz Hot/Live Brass Silver Ground No lights at all or no fan response Power not present • Circuit breaker OFF or tripped. Perform Short Circuit Check. • FASS is in the OFF position. Move FASS to the ON position by fully pushing it in. Check both the Dimmer / Fan Control / Switch and all of the Remote Dimmers / Switches. Tighten1 Green 120 V 50 / 60 Hz Neutral Cause and Action Blue Black Lighting Load Symptom Load Ground Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Neutral Wiring Diagram 3 Multi-Location Installation2 -6D, -10D with HD-RD Remote Dimmer Brass Blue Brass Blue Lamps burned out or not installed • Replace or install lamps. Dimmer Remote Dimmer Brass Dioded lamps • If dioded lamps are being used, replace with non-dioded lamps. Blue Hot/Live Black Black Green 120 V 50 / 60 Hz Ground Green Black Green Ground Fan setting • Make sure the fan is set to its highest speed using the pull-chain. Lighting Load Ground Fan Speed Control Wrong Load Type • Make sure that only a single ceiling paddle fan (permanent split-capacitor motor) rated at 2 A or less is connected to the control. • Make sure that no lighting load (i.e. light kit) is connected to the control. Neutral Wiring Diagram 4 Multi-Location Installation with Neutral2, 3 -6ND, -10ND, -2ANF with HD-RD, -8ANS with HD-RS Remote Dimmer/Switch Brass Remote Dimmer/Switch Blue Brass Blue Hot/Live Black Green 120 V 50 / 60 Hz Black Ground Green Dimmer / Switch / Fan Speed Control Brass Silver Blue Black Green Ground 1W hen using controls in single location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or to ground. 2U p to 9 HomeWorks Maestro Remote Dimmers / Switches may be connected to the HomeWorks RF Maestro Dimmer / Switch / Fan Speed Control. Total blue terminal wire length may be up to 250 ft. (76 m). Status LEDs Indicates light / speed level; glow softly as night light when load is off Wiring • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Light turns ON and OFF continuously Load is less than minimum load requirement • Make sure the connected load meets the appropriate minimum load requirement for that control. See Load Specifications. Lights / fan don’t switch ON / OFF when Tapswitch on Dimmer / Switch / Fan Speed Control/ Remote is pressed Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. • Neutral-based product installation location. Check that neutral-based products are connected on the load side of a multi-location installation (see Wiring Diagram 4). Lights / fan don’t switch ON/OFF from Keypad Improper programming • Check programming in the HomeWorks software. Load Ground Neutral Dimmer / Fan Operation Lights / fan turn ON when Tapswitch is pressed, then turn OFF Switch Operation Status LED Indicates light status; glows softly as night light when light is off Tapswitch Tap on/off Wallbox Included: Dimmer / Switch / Fan Speed Control 3N eutral wire Dimmers / Switches / Fan Speed Controls must be connected on the Load side of a multi-location installation. Mounting Diagram Control 1. T urn power OFF at fusebox or circuit breaker. Wire Connector (1) 2. P repare wires. When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connector. Note: Wire connectors provided are suitable for copper wire only. Wire Connector: Mounting Screws (2) • Strip insulation 3/8 in. (9.5 mm) for 14 AWG (1.5 mm2) wire • Strip insulation 1/2 in. (12.7 mm) for 16 or 18 AWG (1.0 mm2 or 0.75 mm2) wire • Use to join one 14 AWG Twist wire (1.5 mm2) or 12 AWG connector (2.5 mm2) ground wire with one tight. 18 AWG (0.75 mm2) control ground wire. Wiring Diagram 2 Single Location Installation -6D, -10D a. Install wallplate adapter onto front of control(s). b. T ighten control mounting screws until wallplate adapter is flush to wall (do not over-tighten). Troubleshooting Guide Wiring Diagram 1 Wallplate/Adapter purchased separately. Dimming Rocker Press to Brighten / Increase Speed Press to Dim / Decrease Speed FASSTM Front Accessible Service Switch Out of RF range • Reposition RF Signal Repeater or RF Processor to be within 30 feet (9 m) of control. Wiring • Wires shorted. Make sure the blue terminal is not grounded or shorted to any other wires. • Wiring error. Check wiring to be sure it agrees with installation instructions and wiring diagrams. Tapswitch Tap on/off Wallplate is warm Solid-state control dissipation • Solid-state dimmers, switches, and fan controls internally dissipate about 2% of the total connected load. It is normal for dimmers, switches, and fan controls to feel warm to the touch during operation. Control is buzzing or humming It is normal for dimmers, switches, and fan controls to emit a slight buzzing or humming sound. FASS Front Accessible Service Switch Lamp Replacement Tapswitch stuck • Tapswitch stuck at another location. Check to see that tapswitches are not sticking for all control locations in the circuit. WARNING - For any procedure other than routine lamp replacement, power must be disconnected at the main electrical panel. Working with power ON may result in personal injury or death. *N ote: Refer to Application Note # 217—“HomeWorks® Maestro® Controls Reference Guide” for advanced features of the HomeWorks Maestro controls. For routine lamp replacement, remove power from the fixture(s) by pulling the FASS switch out on both the Dimmer / Switch and all Remote Dimmers / Switches. These products may be covered under one or more of the following U.S. patents: 4,835,343; 5,248,919; 5,399,940; 5,637,930; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,687,487; 6,803,728; D353,798 and corresponding foreign patents. U.S. and foreign patents pending. Lutron, Claro, Satin Colors, Maestro, HomeWorks and the sunburst logo are registered trademarks and FASS and the HomeWorks logo are trademarks of Lutron Electronics Co., Inc. © 2008 Lutron Electronics Co., Inc. Warranty: For Warranty information, please see the Warranty enclosed with the product, or visit www.lutron.com/resiinfo.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1-702 Instance ID : uuid:38b7fe53-c631-49ff-9c38-77cc1b1f3f9c Document ID : adobe:docid:indd:266ad284-bac9-11dc-a329-f57e3527b1dd Rendition Class : proof:pdf Derived From Instance ID : 266ad283-bac9-11dc-a329-f57e3527b1dd Derived From Document ID : adobe:docid:indd:266ad282-bac9-11dc-a329-f57e3527b1dd Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:6081411C76C5DA11BDC9A93607A846D6, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:4EDBB214E7D6DA1188E2FB855D1D5C91, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:6081411C76C5DA11BDC9A93607A846D6, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:4EDBB214E7D6DA1188E2FB855D1D5C91, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:6081411C76C5DA11BDC9A93607A846D6, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:4EDBB214E7D6DA1188E2FB855D1D5C91, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:6081411C76C5DA11BDC9A93607A846D6, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91, uuid:4EDBB214E7D6DA1188E2FB855D1D5C91, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:4CDBB214E7D6DA1188E2FB855D1D5C91 Manifest Reference Document ID : uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:5F81411C76C5DA11BDC9A93607A846D6, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:4DDBB214E7D6DA1188E2FB855D1D5C91, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:5F81411C76C5DA11BDC9A93607A846D6, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:4DDBB214E7D6DA1188E2FB855D1D5C91, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:5F81411C76C5DA11BDC9A93607A846D6, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:4DDBB214E7D6DA1188E2FB855D1D5C91, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:5F81411C76C5DA11BDC9A93607A846D6, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91, uuid:4DDBB214E7D6DA1188E2FB855D1D5C91, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:4BDBB214E7D6DA1188E2FB855D1D5C91 Create Date : 2008:02:25 08:40:29-05:00 Modify Date : 2009:09:25 08:13:51-04:00 Metadata Date : 2009:09:25 08:13:51-04:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Has XFA : No Page Count : 1 Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools