Lutron Electronics 0062 Dimmer or Switch User Manual 7

Lutron Electronics Company Inc Dimmer or Switch 7

User Manual 7

Download: Lutron Electronics 0062 Dimmer or Switch User Manual 7
Mirror Download [FCC.gov]Lutron Electronics 0062 Dimmer or Switch User Manual 7
Document ID1175469
Application IDmEtE+0n8+BFkAgmiqksHFQ==
Document DescriptionUser Manual 7
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.76kB (371943 bits)
Date Submitted2009-09-25 00:00:00
Date Available2009-09-25 00:00:00
Creation Date2009-08-21 11:15:03
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2009-09-25 08:11:02
Document TitleUser Manual 7
Document CreatorAdobe InDesign CS3 (5.0.4)

English
Designer-Style RF Maestro®
Dimmers: RRD-6D, RRD-10D, RRD-10ND
Switch: RRD-8ANS
Typical Power Consumption*: 0.2 W
Remote Dimmer: RD-RD
Remote Switch: RD-RS
Typical Power Consumption*: 0 W
Installation Instructions
Please Read Before Installing
120 V
50 / 60 Hz
Important Notes
Dimmer
Remote
Dimmer
Switch
Remote
Switch
Use these instructions to install the
model numbers listed above. For system
setup instructions and tools visit
www.lutron.com/radiora2
Load Specifications:
Control
Load
Type
Min.
Load
Incand.
50 W
600 W
MLV2
50 W / VA
450 W /
600 VA
-6D
Incand.
-10D
50 W
1000 W
MLV
50 W / VA
800 W /
1000 VA
Incand.
10 W
1000 W
10 W / VA
800 W /
1000 VA
-10ND
-8ANS
Max.
Load
MLV
Lighting
10 W / VA
8A
Motor
0.08 A
1/4 HP
5.8 A
-RD
See Dimmer
8.3 A
-RS
See Switch
8.3 A
1D
 immer Load Type: -6D, -10D and -10ND are
designed for use with permanently installed
incandescent, magnetic low-voltage, or tungsten halogen only. Do not install dimmers to
control receptacles or motor-operated appliances.
2L
 ow-Voltage Applications: Use -6D,
-10D and -10ND with magnetic (core and coil)
low-voltage transformers only. Not for use with
electronic (solid-state) low-voltage transformers.
3S
 witch Load Type: -8ANS is designed for
use with permanently installed incandescent,
magnetic low-voltage, electronic low-voltage,
or fluorescent loads and with motor loads up to
1/4 HP (5.8 A).
*Typical Power Consumption test conditions:
Dimmer: load is off, nightlight mode enabled.
Switch: load is off, nightlight mode enabled.
Remote Dimmer / Switch: load is off.
Technical Assistance:
U.S.A. / Canada: 1.800.523.9466
Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800
24 hours a day, 7 days a week.
Lutron Elec­tron­ics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
Made and print­ed in the U.S.A. 7 / 09 P/N 044-157 Rev. A
WARNING - To avoid the risk
of entrapment, serious injury, or
death, these controls must not be
used to control equipment which is not
visible from every control location or which
could create hazardous situations such
as entrapment if operated accidentally.
Examples of such equipment which must
not be operated by these controls include
(but are not limited to) motorized gates,
garage doors, industrial doors, microwave
ovens, heating pads, etc. It is the installer’s
responsibility to ensure that the equipment being controlled is visible from every
control location and that only suitable
equipment is connected to these controls.
Failure to do so could result in serious
injury or death.
Codes: Install in accordance with all local
and national electrical codes.
Grounding: When no “grounding means”
exist within the wallbox, then the NEC®
2008, Article 404.9 allows a dimmer without a grounding connection to be installed
as a replacement, as long as a plastic,
noncombustible wallplate is used. For
this type of installation, cap or remove the
green ground wire on the dimmer and use
an appropriate wallplate such as Lutron’s
Claro® or Satin Colors® wallplates.
Neutral Wire: -10ND and -8ANS require
a neutral wire connection in the wallbox
where the Dimmer/Switch is to be installed.
If a neutral wire connection is not available
in the wallbox, contact a licensed electrician for installation.
Environment: Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing.
Indoor use only.
Spacing: If mounting one control above
another, leave at least 4 ½ in (114 mm) vertical space between them.
Wallplates: Lutron® Claro and Satin Colors
wallplates are recommended for best color
match and aesthetic appearance. Do not
paint controls or wallplates.
Cleaning: To clean, wipe with a clean
damp cloth. Do not use any chemical
cleaning solutions.
Wallboxes: Lutron recommends using
3 ½ in (89 mm) deep wallboxes for easier installation. Several controls may be
installed in one multigang wallbox — see
Derating Chart.
Remote Dimmers / Switches: Use only
Lutron Maestro Remote Dimmers (-RD)
with -6D, -10D, and -10ND controls. Use
only Lutron Maestro Remote Switches
(-RS) with -8ANS controls. Up to 9 -RD or
-RS controls may be used with Maestro
Dimmers or Switches. Mechanical 3- or
4-way switches will not work
RF Device Placement: RF Dimmers and
Switches must be located within 30 feet
(9 m) of an RF Signal Repeater. Remote
Dimmers and Switches are not required to
be within a specific range of a repeater.
For systems with an RF signal repeater, RF
Dimmers or Switches cannot be controlled
by the system until they are programmed
in a system according to the system Setup
Guide.
Multigang Installations
In multigang installations, several controls
are grouped horizontally in one multigang
wallbox.
Trim or strip wallbox wires to the length
indicated by the strip gauge on the back of the
control.
When combining controls in a wallbox,
derating is required; however, no derating
is required for Remote Dimmers / Switches.
Derating Chart
Push-In Terminals: Insert
wires fully. To release wire,
insert small, flat screwdriver
into slot below push-in
terminal. Push screwdriver in
while pulling wire out. Push-in
terminals are for use with
14 AWG (1.5 mm2) solid copper
wire only. DO NOT use
stranded or twisted wire.
OR
Screw Terminals: Wrap
wire around screw terminal.
Tighten securely to 5 in-lbs
(0.55 N•m). Screw terminals
are for use with 12 AWG
(2.5 mm2) or 14 AWG
(1.5 mm2) solid copper wire
only. DO NOT use stranded or
twisted wire.
Control
-6D
-10D,
-10ND
-8ANS
Load
Type
End of
Gang
Middle of
Gang
Incand.
500 W
400 W
MLV
400 W /
500 VA
300 W /
400 VA
Incand.
800 W
650 W
MLV
600 W /
800 VA
500 W /
650 VA
Lighting
6.5 A
5A
Motor
1/4 HP
5.8 A
1/6 HP
4.4 A
Note: -8ANS controls have fins that need
to be removed for multigang installations.
-6D, -10D, -10ND, -RD and -RS controls
do not have fins that need to be removed
for multigang installations.
Removing Fins on -8ANS
Do Not remove outside fins on
Controls at the end of gang
Control at middle
of Gang has all fins
removed
Installation
WARNING - To avoid the risk of
electric shock locate and remove
fuse or lock circuit breaker in the
OFF position before proceeding. Wiring
with power ON could result in serious
injury or death.
Short Circuit Check: Check the
installation for short circuits before
installing control(s). With power OFF, install
standard mechanical switch(es) between
Hot and load. Restore power. If lights do
not work or a breaker trips, check wiring.
Correct wiring and check again. Install
control(s) only when short is no longer
present. Warranty is void if control is
turned ON with a shorted circuit.
1. T
 urn power OFF at fusebox or circuit
breaker.
2. P
 repare wires. When making wire connections, follow the recommended strip
lengths and combinations for the supplied wire connector.
Note: Wire connector provided is suitable for copper wire only.
Wire Connector:
• Strip insulation 3/8 in (10 mm) for
14 AWG (1.5 mm2) or 12 AWG
(2.5 mm2) wire
• Strip insulation 7/16 in
(11 mm) for 18 AWG (0.75 mm2)
wire
• Use to join one or two 14 AWG Twist wire
(1.5 mm2) or 12 AWG (2.5 mm2) connector
wires with one 18 AWG
tight.
(0.75 mm2) ground wire.
Single Location Installation with Neutral
-10ND, -8ANS
Brass
Black
Green
Hot/Live
Blue
Tighten1
Ground
Green
120 V
50 / 60 Hz
Symptom
Probable Cause and Action
Lights don’t switch
ON / OFF when
Tapswitch on
Dimmer / Switch/
Remote is pressed
Power not present
• Circuit breaker OFF or tripped. Perform Short Circuit Check.
•F
 ASS is in the OFF position. Move FASS to the ON position
by fully pushing it in. Check both the Dimmer  / Switch and all
of the Remote Dimmers / Switches.
Load
Wiring
• Wires shorted. Make sure the blue terminal is not grounded
or shorted to any other wires.
• Wiring error. Check wiring to be sure it agrees with
installation instructions and wiring diagrams.
• Installed in a neutral-based location. Check that neutralbased products are connected on the load side of a multilocation installation (see Wiring Diagram 4).
Ground
Neutral
Wiring Diagram 3
Multi-Location Installation2
-6D, -10D with RD-RD
Remote Dimmer
Brass
Blue
Remote Dimmer
Brass
Blue
Lamps burned out or not installed
• Replace or install lamps.
Dimmer
Brass
Dioded lamps
• If dioded lamps are being used, replace with non-dioded
lamps.
Blue
Hot/Live
Black
c. S
 nap wallplate onto wallplate adapter,
and verify that control is aligned properly.
d. If controls are misaligned, loosen
mounting screws appropriately.
6. R
 estore power. Verify correct local
operation (see Dimmer Operation and
Switch Operation).
Mounting Diagram
Green
120 V
50 / 60 Hz
Black
Ground
Green
Black
Green
Lighting
Load
Ground
Ground
Neutral
Multi-Location Installation with Neutral2, 3
-10ND with RD-RD, and -8ANS with RD-RS
Remote Dimmer/Switch
Brass
Blue
Remote Dimmer/Switch
Brass
Blue
Hot/Live
Black
Green
120 V
50 / 60 Hz
Black
Wire Connector (1)
Wallplate
Adapter Wallplate
Mounting Screws (2)
Wallplate adapter and
wallplate purchased
separately.
Light turns ON and
OFF continuously
Load is less than minimum load requirement
• Make sure the connected load meets the appropriate
minimum load requirement for that control. See Load
Specifications.
Ground
Green
Brass
Silver
Blue
Lights don’t switch
ON/OFF from a
Keypad
Improper programming
• Program according to the system Setup Guide.
Black
Green
Load
Ground
Ground
1W
 hen using controls in single location installations, tighten the blue terminal without
any wires attached. Do not connect the blue terminal to any other wiring or to
ground.
2U
 p to 9 Remote Dimmers / Switches may be connected to a Dimmer / Switch. Total blue
terminal wire length may be up to 250 ft (76 m).
Dimmer Operation
Tapswitch stuck
• Tapswitch stuck at another location. Check to see that
tapswitches are not sticking for all control locations in the
circuit.
Out of RF range
• Reposition to be within 30 feet (9 m) of an RF Signal
Repeater.
Wiring
• Wires shorted. Make sure the blue terminal is not grounded
or shorted to any other wires.
• Wiring error. Check wiring to be sure it agrees with
installation instructions and wiring diagrams.
Neutral
Status LEDs (Dimmer Only)
Indicate light level; glows softly as
night light when load is off
Wallbox
Wiring
• Wiring error. Check wiring to be sure it agrees with
installation instructions and wiring diagrams.
Dimmer / Switch
3N
 eutral wire Dimmers / Switches must be connected on the Load side of a multi-location
installation.
Adapter
Mounting
Screws
Lights turn ON
when Tapswitch is
pressed, then turn
OFF
Wiring Diagram 4
a. Install wallplate adapter onto front of
control(s).
Control
Brass
Silver
Black
Lighting
Load
Neutral
5. A
 ttach the Lutron Claro or Satin Colors
wallplate adapter and wallplate.
Included:
Blue
120 V
50 / 60 Hz
3. W
 ire controls as follows:
For single location installation: See
Wiring Diagrams 1 and 2.
For multi-location installation: See
Wiring Diagrams 3 and 4.
Control
Mounting
Screws
Dimmer / Switch
Tighten1
Hot/Live
b. T
 ighten control mounting screws until
wallplate adapter is flush to wall (do
not over-tighten).
Each control
has inside
fins removed
Wiring Diagram 2
Single Location Installation
-6D, -10D
Dimmer
4. P
 ush all wires back into the wallbox and
loosely fasten the control to the wallbox
using the control mounting screws provided. Do not pinch the wires.
Control Location for Ganging
Troubleshooting Guide
Wiring Diagram 1
Wallplate is warm
Solid-state control dissipation
• Solid-state dimmers and switches internally dissipate about
2% of the total connected load. It is normal for dimmers and
switches to feel warm to the touch during operation.
Switch Operation
Status LED (Switch Only)
Indicates light status; glows softly
as night light when load is off
Tapswitch
Tap on/off
Dimming Rocker
Press to Brighten
Tapswitch
Tap on/off
Press to Dim
FASSTM
Front
Accessible
Service
Switch
FASS
Front
Accessible
Service
Switch
Lamp Replacement
WARNING - Shock Hazard - For any procedure other than routine lamp
replacement, power must be disconnected at the main electrical panel. Working
with power ON could result in serious injury or even death.
For your safety during routine lamp replacement, remove power from the fixture(s)
by pulling the FASS switch out on both the Dimmer / Switch and all Remote
Dimmers / Switches.
Returning Devices to Factory Settings
Note: Returning a control to its Factory Settings will remove the control from the system
and erase all programming.
Step 1 : Triple tap the tapswitch on the control. DO NOT release after the third tap.
Step 2 : Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until
the status LEDs start to scroll up and down quickly.
Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The status
LEDs will scroll up and down slowly.
The control has now been returned to Factory Settings.
Warranty: For warranty information, please see the enclosed Warranty, or visit
www.lutron.com/resiinfo.
These products may be covered under one or more of the following U.S. patents: 4,992,709; 5,248,919; 5,399,940; 5,637,930; 5,798,581; 5,838,226; 5,848,054; 5,905,442; 5,982,103; 6,169,377; 6,687,487; 6,803,728; 6,969,959; 7,071,634; 7,166,970; 7,190,125; 7,362,285;
7,365,282; 7,382,100; 7,408,525; 7,548,216 and corresponding foreign patents. U.S. and foreign patents pending. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, Maestro, RadioRA and the
sunburst logo are registered trademarks and RadioRA 2 and FASS are trademarks of Lutron Electronics Co., Inc.
©2009 Lutron Electronics Co., Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Instance ID                     : uuid:0185e233-482f-4fc6-8836-bb18d111516d
Document ID                     : adobe:docid:indd:033f7906-6288-11de-99b6-c473c2095c06
Rendition Class                 : proof:pdf
Derived From Instance ID        : 86467921-4089-11de-ba46-ff892043cc2d
Derived From Document ID        : adobe:docid:indd:c99fca8a-3e28-11de-84cd-cd0d1f4bf3a3
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:8A466DE623D5DA118F56D14712628810, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E, uuid:E2B81D5BCA20DB11B8E1E0790019C4D1, uuid:C8EA34FB72C5DA11BDC9A93607A846D6, uuid:2B6296D3770DDE118206A0EE903D8456, uuid:CCEA34FB72C5DA11BDC9A93607A846D6, uuid:E1B81D5BCA20DB11B8E1E0790019C4D1, uuid:8A466DE623D5DA118F56D14712628810, uuid:0A185B40311ADE11B6228246EB4B0D61, uuid:10217756460FDE11B8F0AED43BA2159E, uuid:12217756460FDE11B8F0AED43BA2159E
Manifest Reference Document ID  : uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:89466DE623D5DA118F56D14712628810, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E, uuid:D0EA34FB72C5DA11BDC9A93607A846D6, uuid:C7EA34FB72C5DA11BDC9A93607A846D6, uuid:2A6296D3770DDE118206A0EE903D8456, uuid:CBEA34FB72C5DA11BDC9A93607A846D6, uuid:C9EA34FB72C5DA11BDC9A93607A846D6, uuid:89466DE623D5DA118F56D14712628810, uuid:09185B40311ADE11B6228246EB4B0D61, uuid:0F217756460FDE11B8F0AED43BA2159E, uuid:11217756460FDE11B8F0AED43BA2159E
Create Date                     : 2009:08:21 11:15:03-04:00
Modify Date                     : 2009:09:25 08:11:02-04:00
Metadata Date                   : 2009:09:25 08:11:02-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 13141 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Has XFA                         : No
Page Count                      : 1
Creator                         : Adobe InDesign CS3 (5.0.4)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0062

Navigation menu