Lutron Electronics 0090 Shadow Sensor User Manual

Lutron Electronics Company Inc Shadow Sensor

User Manual

Mounting1  Prepare the window glass surface by wiping with a clean, dry cloth. 2  First, read all the remaining steps and notes in this section, then peel off the protective adhesive liner on the back of the sensor and proceed immediately to step 3.3  With the arrow on the front of the sensor pointing straight up, press the sensor fi rmly to the window surface, holding for a minimum of 5 seconds.NOTE: The sensor can be removed and repositioned one time within 15 seconds of initial contact with the window surface. After 15 seconds, or if a second repositioning is necessary, you must replace the sensor’s back cover with Lutron Part Number: “RSS-REPCOVER”IMPORTANT: The factory-applied mounting adhesive is positioned to allow the sensor to operate properly. DO NOT apply any other type of adhesive. Application of additional tape or liquid bonding agents will obstruct the sensor and/or cause permanent damage.Instructions Install a sensor in as little as 15 minutes.Getting Started:Key Features•  Easy Installation. No wiring required.•   Easy Set-Up. Default settings are ideal for most situations. Simple and intuitive adjustments available.•   Low Maintenance. 10-year battery life.Sensor Operation:Hyperion solar-adaptive shading technology automatically positions shades based on the position of the sun. The Radio Shadow Sensor will monitor exterior lighting conditions and override Hyperion when shadows are cast by clouds or neighboring buildings, and re-enable Hyperion when sunlight returns.How it works:•  This battery powered photo sensor reports the measured amount of natural light incident on a facade to Quantum using Lutron Clear Connect Technology.•  Enables Quantum to override Hyperion by moving shades to an opened visor position when outdoor conditions indicate shadows from clouds or other obstructions.REAR VIEW w/COVER REMOVEDFRONT VIEWUse laserto linkto systemBatterycompartmentdoorBatterycompartmentUse totest systemfunctionalityUse to linkto system®Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299, U.S.A.Made and printed in the U.S.A. 10/12 P/N 045-379 Rev. AImportant Notes1.   This sensor is part of a system and cannot be used to control a load or shade without a compatible Lutron Quantum Total Light Management System with Hyperion Solar Adaptive Technology. Refer to the instruction sheets of the receiving devices for installation information on setup and testing of this sensor.2.  Clean sensor with a soft damp cloth only. DO NOT use any chemical cleaners.3.   For indoor use only. Operate between 32 °F and 122 °F (0 °C and 50 °C).4.  DO NOT paint sensor.5.   Use only high-quality lithium batteries, one (1) size CR2450, 3 V  (ANSI-5029LC, IEC-CR2450). DO NOT use rechargeable batteries. Using improperly rated batteries could damage the sensor. NOTICE: DO NOT disassemble, crush, puncture, or incinerate batteries. DO NOT dispose of batteries in normal household waste. Please recycle, take to a proper battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries.WARNING: Keep battery out of reach of children. If swallowed, immediately seek medical help as serious injury may occur. Have doctor phone 24-hour hotline at (202) 625-3333, collect.6.    California residents:The batteries in these devices contain Perchlorate Material–special handling may apply. For more information visit www.dtsc.ca.gov/hazardouswaste/perchlorate.7.   The range and performance of the RF system is highly dependent on a variety of complex factors such as:• Distance between system components• Geometry of the building structure• Construction of walls separating system components• Electrical equipment located near system componentsWARNING: Entrapment hazard. To avoid the risk of entrapment this product must not be used to control equipment which could create hazardous situations, such as entrapment, if operated accidentally. Examples of equipment which must not be controlled with this product include (but are not limited to) motorized gates, garage doors, industrial doors, etc. Accidental operation of the above equipment with this product could result in serious injury or death. Easy-to-follow InstructionsP/N 045-379Limited Warranty(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CON NEC TION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PUR CHASE PRICE OF THE UNIT.This warranty gives you specifi c legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you. Lutron, Maestro Wireless, Grafi k Eye and the Sunburst logo are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc. ANSI is a registered trademark of the American National Standards Institute. IEC is a trademark of the International Electrotechnical Commission. 3M and Command are trademarks of 3M Company. © 2010 Lutron Electronics Co., Inc.Technical AssistanceFor questions concerning the installation or operation of this product, call the Lutron Technical Support Center. Please provide exact model number when calling.U.S.A. and Canada (24 hrs / 7 days)1.800.523.9466  Fax +1.610.282.6311Mexico 8am – 8pm ET+1.888.235.2910Other countries 8am – 8pm ET+1.610.282.3800  www.lutron.comFCC/ IC InformationThis device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Modifi cations not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.EnglishRadio Shadow Sensor™Installation Instructions Please Read Before InstallingWireless Battery-Powered Window sensorLRF2-SSW   3 V   7 µA  434 MHzCompatible ProductsFor a full list of compatible products visit www.lutron.comProduct DescriptionLutron’s Radio Frequency-Enabled Radio Shadow Sensor enhances the performance of Hyperion™ solar-adaptive shading systems when direct sunlight is being blocked by external means. This sensor maximizes natural daylight, available views and occupant comfort when shadows are cast on buildings or cloudy conditions prevail. The sensor works at the window level to communicate current exterior light conditions to the Quantum® Total Light Management System, enabling Hyperion to respond appropriately, improve occupant comfort and enhance the system’s energy-saving potential. The battery-powered sensor features easy installation and low maintenance costs.NOTE: Before setting up the sensor, the corresponding Lutron Quantum Total Light Management System should be installed. Refer to that product’s installation instructions.Use only high-quality lithium batteries, one (1) size CR2450, 3 V  (ANSI-5029LC, IEC-CR2450). DO NOT use rechargeable batteries. Using improperly rated batteries could damage the sensor. NOTICE: DO NOT disassemble, crush, puncture, or incinerate batteries. DO NOT dispose of batteries in normal household waste. Please recycle, take to a proper battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries.WARNING: Keep battery out of reach of children. If swallowed, immediately seek medical help as serious injury may occur. Have doctor phone 24-hour hotline at (202) 625-3333, collect. California  residents:The batteries in these devices contain Perchlorate Material–special handling may apply. For more information visit www.dtsc.ca.gov/hazardouswaste/perchlorate.1  Remove the sensor’s back cover by pulling it straight off.2  Swing open the battery door. Insert battery with the negative side up, as shown.3  Swing the battery door closed and gently snap it into locked position.4  Align  the arrow on the inside of the back cover with the arrow on the front of the sensor and reinstall the back cover.ArrowsAInstall Battery BInstall SensorPlacementBecause of the way shadows move across a facade, it is recommended to mount the Radio Shadow Sensor on the upper-right corner, (viewed from the inside), of the window for locations in the Northern Hemisphere— or the upper-left corner, (viewed from the inside), of the window for locations in the Southern Hemisphere.•  The arrow on the Radio Shadow Sensor points up.•   Ensure that the exterior view of the Radio Shadow Sensor is not obstructed.•   Do not position the Radio Shadow Sensor on a skylight or in the path of electric light.•  Affi x the Radio Shadow Sensor directly to the interior window glass.•  The photo-receptor on the rear of the device must have an unobstructed view of the outside.•   Mount sensor(s) at least 6 in (152 mm) away from large metal surfaces (e.g. metal window frames). Metal objects will affect the sensor’s RF performance.   LUTRONCal.LinkTestLUTRONCal.LinkTestSingle-window (view from inside building)One sensor for multiple windowsNorthern Hemisphere6 in (152 mm) min.6 in (152 mm) min.6 in (152 mm) min.SensorpositionSouthern HemisphereLUTRONCal.LinkTestLUTRONCal.LinkTestCSetup SensorNOTE: This sensor is part of a system and cannot be used to control a load or shade without a compatible Lutron Quantum Total Light Management System with Hyperion Solar Adaptive Technology. Refer to the instruction sheets of the receiving devices for information on setup and testing of this sensor.DTroubleshootingSymptom Possible Causes SolutionRoom is too darkSensor is too close to the window frame Refer to section C. sensor PlacementDirect light from a fi xture is shining on the sensor Refer to section C. sensor PlacementRoom layout may have changed Refer to section E. CalibrationLights seem unnecessarily brightsensor is too far away from the window Refer to section C. sensor PlacementSystem was calibrated when it was too bright outside Refer to section E. CalibrationLights never turn back on when the room gets darkThe system may not have an Occupancy sensor associated to it  Refer to Getting Started: sensor Operation The battery in the Occupancy sensor may need to be replaced Replace battery. For more details, refer to Frequently Asked Questions at www.lutron.comSystem was calibrated when it was too dark outside Refer to section E. CalibrationLights never turn off when the room gets brightSystem was calibrated when it was too bright outside Refer to section E. CalibrationTarget light level is too high Refer to section G. Tuning the SystemThe lights oscillate (lights turn on, off, on, ...)Direct light from a fi xture is shining on the sensor Refer to section C. sensor PlacementSystem was not calibrated Refer to section E. CalibrationMounting1  Prepare the window glass surface by wiping with a clean, dry cloth. 2  First, read all the remaining steps and notes in this section, then peel off the protective adhesive liner on the back of the sensor and proceed immediately to step 3.3  With the arrow on the front of the sensor pointing straight up, press the sensor fi rmly to the window surface, holding for a minimum of 5 seconds.NOTE: The sensor can be removed and repositioned one time within 15 seconds of initial contact with the window surface. After 15 seconds, or if a second repositioning is necessary, you must replace the sensor’s back cover with Lutron Part Number: “RSS-REPCOVER”IMPORTANT: The factory-applied mounting adhesive is positioned to allow the sensor to operate properly. DO NOT apply any other type of adhesive. Application of additional tape or liquid bonding agents will obstruct the sensor and/or cause permanent damage.Instructions Install a sensor in as little as 15 minutes.Getting Started:Key Features•  Easy Installation. No wiring required.•   Easy Set-Up. Default settings are ideal for most situations. Simple and intuitive adjustments available.•   Low Maintenance. 10-year battery life.Sensor Operation:Hyperion solar-adaptive shading technology automatically positions shades based on the position of the sun. The Radio Shadow Sensor will monitor exterior lighting conditions and override Hyperion when shadows are cast by clouds or neighboring buildings, and re-enable Hyperion when sunlight returns.How it works:•  This battery powered photo sensor reports the measured amount of natural light incident on a facade to Quantum using Lutron Clear Connect Technology.•  Enables Quantum to override Hyperion by moving shades to an opened visor position when outdoor conditions indicate shadows from clouds or other obstructions.REAR VIEW w/COVER REMOVEDFRONT VIEWUse laserto linkto systemBatterycompartmentdoorBatterycompartmentUse totest systemfunctionalityUse to linkto system®Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299, États-Unis10/12 P/N 045-379 Rev. AImportant Notes1.   This sensor is part of a system and cannot be used to control a load or shade without a compatible Lutron Quantum Total Light Management System with Hyperion Solar Adaptive Technology. Refer to the instruction sheets of the receiving devices for installation information on setup and testing of this sensor.2.  Clean sensor with a soft damp cloth only. DO NOT use any chemical cleaners.3.   For indoor use only. Operate between 32 °F and 122 °F (0 °C and 50 °C).4.  DO NOT paint sensor.5.   Use only high-quality lithium batteries, one (1) size CR2450, 3 V  (ANSI-5029LC, IEC-CR2450). DO NOT use rechargeable batteries. Using improperly rated batteries could damage the sensor. NOTICE: DO NOT disassemble, crush, puncture, or incinerate batteries. DO NOT dispose of batteries in normal household waste. Please recycle, take to a proper battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries.WARNING: Keep battery out of reach of children. If swallowed, immediately seek medical help as serious injury may occur. Have doctor phone 24-hour hotline at (202) 625-3333, collect.6.    California residents:The batteries in these devices contain Perchlorate Material–special handling may apply. For more information visit www.dtsc.ca.gov/hazardouswaste/perchlorate.7.   The range and performance of the RF system is highly dependent on a variety of complex factors such as:• Distance between system components• Geometry of the building structure• Construction of walls separating system components• Electrical equipment located near system componentsWARNING: Entrapment hazard. To avoid the risk of entrapment this product must not be used to control equipment which could create hazardous situations, such as entrapment, if operated accidentally. Examples of equipment which must not be controlled with this product include (but are not limited to) motorized gates, garage doors, industrial doors, etc. Accidental operation of the above equipment with this product could result in serious injury or death. Instructions faciles à suivreP/N 045-379Garantie limitée(valable seulement aux É.-U., au Canada, à Porto Rico et dans les Caraïbes)Lutron réparera ou remplacera, à sa discrétion, tout équipement jugé défectueux quant aux matériaux ou à la fabrication durant un an à compter de la date d’achat. Pour le service de garantie, veuillez retourner l’équipement au détaillant ou par courrier affranchi à Lutron au 7200 Suter Rd., Coopersburg, PA 18036-1299.CETTE GARANTIE TIENT LIEU ET REMPLACE TOUTE AUTRE GARANTIE EXPRESSE, ET LA GARANTIE TACITE DE QUALITÉ MARCHANDE A UNE DURÉE D’UN AN À COMPTER DE LA DATE D’ACHAT. CETTE GARANTIE NE COUVRE NI LES FRAIS D’INSTALLATION, DE RETRAIT OU DE RÉINSTALLATION, NI LES DOMMAGES RÉSULTANT D’UN MAUVAIS USAGE OU D’ABUS, NI LES DÉGÂTS PROVOQUÉS PAR UN MAUVAIS CÂBLAGE OU UNE INSTALLATION INADÉQUATE. CETTE GARANTIE NE COUVRE PAS LES DOMMAGES ACCIDENTELS OU INDIRECTS. LA RESPONSABILITÉ DE LUTRON POUR LES RÉCLAMATIONS CONCERNANT DES DOMMAGES PROVENANT DE, OU EN LIEN AVEC LA FABRICATION, LA VENTE, L’INSTALLATION, LA LIVRAISON OU L’UTILISATION DE L’ÉQUIPEMENT NE POURRA JAMAIS DÉPASSER LE MONTANT D’ACHAT DE L’ÉQUIPEMENT.Cette garantie vous accorde des droits juridiques précis et vous pouvez disposer d’autres droits qui varient d’un État à l’autre. Certains États n’autorisent pas l’exclusion ou la limitation des dommages accidentels ou indirects, ou n’autorisent pas de limiter la durée de la garantie tacite; les limitations ci-dessus peuvent ne pas vous concerner.Information de la FCC/ ICCe dispositif est conforme à la section 15 des règlements du FCC et des standards CNR exempt de licence d’Industrie Canada. L’opération est sous réserve des deux conditions suivantes : (1) Cet appareil ne peut causer d’interférence nuisible, et (2) Cet appareil doit tolérer toute interférence, même celle pouvant affecter son fonctionnement. Tout changement ou modifi cation sans l’autorisation expresse de Lutron Electronics Co., Inc. pourrait annuler le droit d’utiliser cet équipement.REMARQUE : Cet équipement a été testé et jugé conforme aux limites applicables aux dispositifs numériques Classe B, conformément à la section 15 des règles de la FCC. Ces limites sont conçues pour procurer une protection raisonnable contre les perturbations nuisibles en application résidentielle. Cet équipement génère, utilise et peut radier l’énergie de fréquences radiophoniques. S’il n’est pas installé et utilisé selon les directives, peut causer des interférences radiophoniques nuisibles. Cependant, il n’y a aucune garantie à l’effet qu’aucune interférence ne se produira dans une installation précise. Si votre équipement produit de l’interférence à la réception radiophonique ou télévisuelle, ce qui peut être détecté en coupant et refermant l’alimentation au système d’éclairage. Dans le cas d’interférence, l’utilisateur sera contraint d’essayer de corriger la situation par un ou plusieurs des moyens suivants :•  Réorienter ou re-localiser l’antenne de réception•  Augmenter la distance séparant l’équipement et le récepteur•   Brancher l’équipement sur un circuit différent que celui sur lequel le récepteur est branché•  Demander l’aide du distributeur ou d’un technicien expérimenté en radio et télévisionFrançaisRadio Shadow Sensor™Instructions d’installation Veuillez les lire avant toute installationSans fi l détecteur de fenêtre pilesLRF2-SSW   3 V   7 µA  434 MHzProduits compatibles/informations supplémentairesPour une liste complète de nos produits compatibles et toute autre information supplémentaire, consulter le site www.lutron.com/occsensorsDescription du produitLutron’s Radio Frequency-Enabled Radio Shadow Sensor enhances the performance of Hyperion™ solar-adaptive shading systems when direct sunlight is being blocked by external means. This sensor maximizes natural daylight, available views and occupant comfort when shadows are cast on buildings or cloudy conditions prevail. The sensor works at the window level to communicate current exterior light conditions to the Quantum® Total Light Management System, enabling Hyperion to respond appropriately, improve occupant comfort and enhance the system’s energy-saving potential. The battery-powered sensor features easy installation and low maintenance costs.NOTE: Before setting up the sensor, the corresponding Lutron Quantum Total Light Management System should be installed. Refer to that product’s installation instructions.Use only high-quality lithium batteries, one (1) size CR2450, 3 V  (ANSI-5029LC, IEC-CR2450). DO NOT use rechargeable batteries. Using improperly rated batteries could damage the sensor. NOTICE: DO NOT disassemble, crush, puncture, or incinerate batteries. DO NOT dispose of batteries in normal household waste. Please recycle, take to a proper battery disposal facility, or contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries.WARNING: Keep battery out of reach of children. If swallowed, immediately seek medical help as serious injury may occur. Have doctor phone 24-hour hotline at (202) 625-3333, collect. California  residents:The batteries in these devices contain Perchlorate Material–special handling may apply. For more information visit www.dtsc.ca.gov/hazardouswaste/perchlorate.1  Remove the sensor’s back cover by pulling it straight off.2  Swing open the battery door. Insert battery with the negative side up, as shown.3  Swing the battery door closed and gently snap it into locked position.4  Align  the arrow on the inside of the back cover with the arrow on the front of the sensor and reinstall the back cover.ArrowsAInstall Battery BInstall SensorPlacementBecause of the way shadows move across a facade, it is recommended to mount the Radio Shadow Sensor on the upper-right corner, (viewed from the inside), of the window for locations in the Northern Hemisphere— or the upper-left corner, (viewed from the inside), of the window for locations in the Southern Hemisphere.•  The arrow on the Radio Shadow Sensor points up.•   Ensure that the exterior view of the Radio Shadow Sensor is not obstructed.•   Do not position the Radio Shadow Sensor on a skylight or in the path of electric light.•  Affi x the Radio Shadow Sensor directly to the interior window glass.•  The photo-receptor on the rear of the device must have an unobstructed view of the outside.•   Mount sensor(s) at least 6 in (152 mm) away from large metal surfaces (e.g. metal window frames). Metal objects will affect the sensor’s RF performance.   LUTRONCal.LinkTestLUTRONCal.LinkTestSingle-window (view from inside building)One sensor for multiple windowsNorthern Hemisphere6 in (152 mm) min.6 in (152 mm) min.6 in (152 mm) min.SensorpositionSouthern HemisphereLUTRONCal.LinkTestLUTRONCal.LinkTestCSetup SensorNOTE: This sensor is part of a system and cannot be used to control a load or shade without a compatible Lutron Quantum Total Light Management System with Hyperion Solar Adaptive Technology. Refer to the instruction sheets of the receiving devices for information on setup and testing of this sensor.DTroubleshootingSymptom Possible Causes SolutionRoom is too darkSensor is too close to the window frame Refer to section C. sensor PlacementDirect light from a fi xture is shining on the sensor Refer to section C. sensor PlacementRoom layout may have changed Refer to section E. CalibrationLights seem unnecessarily brightsensor is too far away from the window Refer to section C. sensor PlacementSystem was calibrated when it was too bright outside Refer to section E. CalibrationLights never turn back on when the room gets darkThe system may not have an Occupancy sensor associated to it  Refer to Getting Started: sensor Operation The battery in the Occupancy sensor may need to be replaced Replace battery. For more details, refer to Frequently Asked Questions at www.lutron.comSystem was calibrated when it was too dark outside Refer to section E. CalibrationLights never turn off when the room gets brightSystem was calibrated when it was too bright outside Refer to section E. CalibrationTarget light level is too high Refer to section G. Tuning the SystemThe lights oscillate (lights turn on, off, on, ...)Direct light from a fi xture is shining on the sensor Refer to section C. sensor PlacementSystem was not calibrated Refer to section E. CalibrationSupport techniqueSi vous avez des questions concernant l’installation ou le fonctionnement de ce produit, veuillez appeler le Centre de soutien technique Lutron. Veuillez fournir le numéro de modèle exact lors de votre appel.États-Unis et Canada (24heurs / 7jours)   Brésil (Lundi-Vendredi 8:30 h à 17:30 h BRT)1.800.523.9466 +55 (11) 3257-6745Mexico de 8h à 20h EST+1.888.235.2910  Télécopieur +1.610.282.6311Autres pays de 8h à 20h EST  +1.610.282.3800 www.lutron.com

Navigation menu