Lutron Electronics 0096 Relay Module User Manual 041423 RF Relay Module with Softswitch INSTALL

Lutron Electronics Company Inc Relay Module 041423 RF Relay Module with Softswitch INSTALL

Contents

Manual 2

Download: Lutron Electronics 0096 Relay Module User Manual 041423 RF Relay Module with Softswitch INSTALL
Mirror Download [FCC.gov]Lutron Electronics 0096 Relay Module User Manual 041423 RF Relay Module with Softswitch INSTALL
Document ID2089139
Application IDThq+2LfSrAmwolaUKA8FYA==
Document DescriptionManual 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize34.86kB (435768 bits)
Date Submitted2013-10-01 00:00:00
Date Available2013-10-01 00:00:00
Creation Date2013-09-26 15:54:52
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2013-09-26 15:55:05
Document Title041423 RF Relay Module with Softswitch INSTALL
Document CreatorAdobe InDesign CS6 (Windows)

RF Relay Module | Installation
Technical Assistance | 1.800.523.9466 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
with SoftswitchR
041423
Rev. A
08/2013
Please read before installing
LMJ-16R-DV-B
120 / 277 V~ 50 / 60 Hz 16 A
1/2 HP at 120 V~
11⁄2 HP at 277 V~
RF Relay Module Operation
For System Setup Guide and tools
visit www.lutron.com
UL 2043 Plenum Rated
LMK-16R-DV-B
LMN-16R-DV-B
220 - 240 V~ 50 / 60 Hz 16 A
6 A Motor (LMK- Model)
Reset Factory Defaults
Load
Status
LED
Note: In some instances it may be
necessary to reset the RF Relay Module
back to factory default settings.
Relay Toggle
Advanced
Operations
Triple-tap the Advanced Operations
(“ADV”) button, on the RF Relay
Module and hold until the LED
begins to flash slowly.
Within 3 seconds of flashing,
release and triple-tap the button
again and the LED will flash
rapidly indicating that the unit has
been reset to factory defaults.
LMM-16R-DV-B
LMQ-16R-DV-B
RF Relay Module
Important Notes:
English
•	
For installation by a qualified electrician in accordance
with all local and national electrical codes.
• Note: Use copper conductors only.
• Check to see that the device type and rating is suitable
for the application.
• DO NOT install if product has any visible damage.
• If moisture or condensation is evident, allow the product
to dry completely before installation.
• Operate between 32 °F to 131 °F (0 °C to 55 °C).
• 0% to 90% humidity, non-condensing.
• For indoor use only.
WARNING
Shock Hazard. May result in
serious injury or death.
Turn off power at circuit breaker
before installing the unit.
FCC Information: (LMJ- model only)
This device complies with part 15 of the FCC Rules and
Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including
interference that may cause undesired operation.
Modifications not expressly approved by Lutron Electronics Co.,
Inc. could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or
more of the following measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Installation:
LMJ-, LMQ-, and LMM- models
When installing a RF Relay Module,
use the supplied conduit nut and
wire the module as shown.
120/277 V~ 50/60 Hz (LMJ- model)
220 - 240 V~ 50/60 Hz (LMQ- and LMM- models)
Note: Any associations or programming
previously set up with the unit will be lost
and will need to be re-programmed.
White
(Neutral)
Black
(Hot)
If installing unit inside a junction box,
please see Application Note #423.
Troubleshooting
Red
(Switched Hot)
For more information: www.lutron.com
Installation:
To Load
Conduit Nut
220 - 240 V~ 50/60 Hz
LMK- and LMN- models
are registered trademarks of Lutron Electronics
Lutron and
Co., Inc.
©2013 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc. | 7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
• Ensure breaker to the
RF Relay Module is on.
• Ensure the load has
been properly wired to
the RF Relay Module.
• Ensure that the RF
Relay Module has been
activated in the system.
• Ensure that the Wireless
Transmitter battery is
installed correctly.
RF Relay
Module does
not respond
to a keypad,
wireless
controller or
sensor.
• Improper programming.
Program from the
system programming
software.
• Out of RF Range.
Reposition to be within
30 ft (9 m) of an RF
signal repeater.
• Already at current level.
The RF Relay Module
has already responded
to a command, or is
already at the requested
setting.
• Wireless controller or
sensor batteries low
or installed incorrectly.
Replace or install
batteries properly.
• RF interference.
Do not run RF Relay
Module wires with
other power wires or
communication wires
(e.g., networking, audio,
or video signals).
Black (LMK-), Yellow (LMN-)
(Switched Line)
Blue (LMK-), Black (LMN-)
RF Relay Module can be installed
in a junction box or marshalling
box (optional) using the conduit nut
(provided) or with mounting screws
(not provided). Please consult local
and national electric codes for
proper installation.
(Neutral)
To Load
Brown (LMK-), Red (LMN-)
(Line)
21 mm knockout opening
Conduit Nut
1 3
10 mm
Wiring a Lever Operated Connector (shown)
When wiring lever operated connectors (3 supplied)
please use 14 AWG to 12 AWG (2.5 mm2 to 4.0 mm2)
diameter solid or stranded copper wire.
For LMN-16R-DV-B use supplied Twist-on wire
connectors. (3 supplied)
Warranty:
For warranty information, please visit
www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf
www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf
Load does
not respond
to Wireless
Transmitter(s).
RF Relay Module Placement
RF Relay Modules must be located within 30 ft (9 m) of an RF signal repeater. RF relay modules cannot
be controlled by the system until they are programmed using the system programming software.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2013:09:26 15:54:52-04:00
Creator                         : Adobe InDesign CS6 (Windows)
Modify Date                     : 2013:09:26 15:55:05-04:00
Subject                         : 041423 RF Relay Module with Softswitch INSTALL
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2013:09:26 15:55:05-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Title                           : 041423 RF Relay Module with Softswitch INSTALL
Description                     : 041423 RF Relay Module with Softswitch INSTALL
Document ID                     : uuid:f91361f3-95d6-44f3-9c9b-2b7952a2872b
Instance ID                     : uuid:2c7c263d-b512-45b8-8fbf-b377d5ab1a79
Producer                        : Adobe PDF Library 10.0.1
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0096

Navigation menu