Lutron Electronics 0105 PowPak Dimming Module Relay Control User Manual Manual PWM

Lutron Electronics Company Inc PowPak Dimming Module Relay Control Manual PWM

Contents

Manual PWM

Need Help? visit www.lutron.com.jp or call Lutron® Technical Support at 0120.083.417041434 Rev. A01/2014Part of the Energi TriPak® FamilyPowPak® | InstallationDimming  Module  with  PWM / 0 – 10  VTestLink Cal. +For each system, ensure that you have:One PowPak® PWM Dimming Module At least one Wireless Transmitter At least one PWM or 0 – 10 V- Fluorescent Ballast or LED DriverRequired ComponentsRadio Powr SavrTM Occupancy/Vacancy Sensor(6 maximum)Radio Powr SavrTM Daylight Sensor(1 maximum)Pico® Wireless Control(9 maximum)Switches up to 5 A total. May be pre-installed in light fixtu e.Control line current - PWM: 150 mA max; 0-10 V-: 60 mAPowPak® Dimming Module with PWM / 0 – 10  V- (1 maximum)RaiseToggleLowerLoad Status LED Consult third-party fixtu es installation guide for fixtu e-specific wiring.Start Here+Occupancy SensorsDaylight SensorWireless ControlsOccupied: All lights 100%.Unoccupied: All lights off.TestLink Cal.All lights dim in response to daylight.On All lights 100%Favorite All lights 50%Off All lights offDefault FunctionalityReset Factory DefaultsNote: In some instances, it may be necessary to reset the PowPak® Dimming Module and connected devices back to factory default settings. Before beginning, make sure that all devices are connected and powered. A  Triple-tap any button on the PowPak® Dimming Module and hold until the LED begins to flashslowly; release button. B  Within 3 seconds of the start of flashing,triple-tap the same button again and the LEDs will flash rapidly indicating that the unit hasbeen reset to factory defaults.Note: Any associations or programming previously set up with the PowPak® will be erased and will need to be re-programmed.2Install PowPak® Dimming ModuleIf installing unit inside a junction box please  see Lutron P/N 369674. For more information: www.lutron.com/powpakrelayA PowPak® Dimming Module can be installed in a junction box or marshalling box using the conduit nut (provided) or with mounting screws (not provided). Please consult local and national electric codes for proper installation.B  Once installed, energize the PowPak® Dimming Module.C  Use the Toggle button “  ” to toggle between high-end and OFF to verify ballast wiring.D  Use the Raise “ ” and Lower “ ” buttons to verify control wiring.ALL PROGRAMMING IS OPTIONALProgramming is not required for default functionality• Set a favorite light level• Set high-end and low-end trim for all fixtu es• Set occupancy levels•Set minimum light level for all fixturesPlease consult individual component installation andprogramming guides for more details.8Set Minimum Light LevelCertain applications (e.g., hallways), may require that the lights never turn off. For these areas, activate Minimum Light Level mode.A  Enter minimum light level adjustment mode:Press and hold Toggle button “  ” and Lower button “ ” for 12 seconds. Lights will flash hig -low-high and LED will begin flashingIf lights stop flashing and go to high-end,the minimum light level is set to OFF (default).If lights stop flashing and go to low-end,the minimum light level is ON and set to low-end.B  Change the minimum light level:Press Raise button “ ” to set minimum light level to low-end.Press Lower button “ ” to set minimum light level to OFF.C  Save the minimum light level:Press and hold Toggle button “  ” for  6 seconds. LED will quickly flash toindicate that new level has been saved.Limited Warranty(Lutron Asuka Company, Ltd., will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.  For warranty service, return unit to place of purchase, or mail to Lutron Asuka Company, Ltd., No. 16 Kowa Building, 4F 1-9-20, Akasaka, Minato-ku Tokyo 107-0052 Japan, postage pre-paid, or telephone Lutron Asuka Company, Ltd., at 03.5575.8411.This warranty is the sole express warranty, and the implied warranty of merchantability, as well as the implied warranty under the Japanese Civil Code (kashi-tampo), is limited to one year from purchase.  This warranty does not cover the cost of installation, removal, or reinstallation, or damage resulting from misuse, abuse, or improper or incorrect repair, or damages from improper wiring or installation.  This warranty does not cover incidental, consequential, or any special damages.  Lutron Asuka Company’s liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit.Lutron, Pico, and PowPak are registered trademarks and Radio Powr Savr is a trademark of Lutron Electronics Co., Inc.©2013 Lutron Electronics Co., Inc.7Set Low-End and High-End TrimLow-End TrimA  Enter low-end trim adjustment mode:Press and hold Lower button “ ” for 12 seconds.Lights will flash high-low-high and LED will begin flashinB  Adjust the low-end trim:Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired low-end (1to 45%).C  Save the low-end trim:Press and hold Toggle button “  ” for 6seconds to save setting.LED will begin flashing and then tu n solid to indicate new level has been saved.High-End TrimD  Enter high-end trim adjustment mode:Press and hold Raise button “ ” for 12seconds.Lights will flash high-low-high and LEDwill begin flashingE  Adjust the high-end trim:Use Raise button “ ” and Lower button “ ” to adjust and set the lights to the desired high-end (55to 100%).F  Save the high-end trim:Press and hold Toggle button “  ” for 6 seconds to save setting.LED will begin flashing and then tu n solid to indicate new level has been saved.PowPak® | ProgrammingDaylight OverridePressing the raise button on an associated Pico® Wireless Control will temporarily override daylighting.Daylight Re-EnableDaylighting will be re-enabled when one of the following occurs:• Two hours have passed since theoverride.*• ON, OFF, or Favorite button has beenpressed on a Pico®Wireless Control.• All associated Occupancy Sensors havereported unoccupied.* Each time a daylighting override occurs,the two-hour timer is reset.EnglishWARNINGShock Hazard. May result in serious injury or death.Turn off power at circuit breaker before installing the unit.All Wireless  Transmitters  must be  installed within  7 m of the  PowPak® Dimming Module.Lutron Electronics Co., Inc.7200 Suter RoadCoopersburg, PA 18036-1299 U.S.A.PWM Control: 12 V-  150 mA 0 – 10  V- Control: 10 V-  60 mAImportant Notes: Please read before installing.For installation by a qualified electrician in acco dance with all local and national electrical codes.• Note: Use copper conductors only.•Check to see that the device type and rating is suitable for theapplication.• DO NOT install if product has any visible damage.•If moisture or condensation is evident, allow the product to drycompletely before installation.•Operate between 0 °C and 40 °C ambient.•0% to 90% humidity, non-condensing.•For indoor use only.120 / 277 V~  50 / 60 Hz  5 ALMJ-5PWM-DV-B Radio Powr SavrTM Occupancy SensorPico®  Wireless ControlPowPak®  Dimming Module7 m max12 m10 mPowPak® Dimming ModuleInstall in center of room  to maximize RF coverage.6Set a Favorite Light LevelFor Pico® Wireless Controls with a Favorite Button.A  Adjust lights to desired level:Use Raise button “ ” or Lower button “ ” on Pico® Wireless Control.B  Save favorite level:Press and hold Favorite button for 6seconds.Raise LowerMount, Wire, and Install PWM/0 – 10 V- Devices and Lighting FixturesConsult third-party device installation guideTurn off power at circuit breaker before installing unit.A  Connect mains wiring (switched hot, neutral) to each fixtu e.B  Connect low-voltage control (+ and – ) to each fixtu e.1+–NEUHOTClass 2MAINSFixture EarthGreen/YellowTo additional fixtu esNeutralSwitched Hot VioletGray+–Sample ballast shownWiring for 200 V~ applications:(requires a 2-pole input breaker)Wiring for 100 V~ applications:Switched Hot (Yellow)–Hot  (Black)To fixtu esControl line to fixtu es*Neutral (White)+Neutral  (White)Junction Box21 mm Knockout OpeningConduit Nut*  Use 0.75 mm2 to 1.5mm2 solid wire only3Associate Wireless Transmitters to PowPak® Dimming ModuleBefore beginning this step, make sure that there are no other PowPak® modules being set up within the same building. It is possible that wireless transmitters from other systems can be incorrectly associated to this module.A  On PowPak® Dimming Module, hold Toggle button “ ” for 6 seconds until lights flashThe Load Status LED will begin flashing twiceper second.B  Hold the indicated button on each transmitter for 6seconds. Lights will flash to show that wireless transmitters have been associated.C   On  PowPak® Dimming Module, hold Toggle button “ ” for 6 seconds to save association. Lights will flash and LED will quickly blink for 2seconds.4Install Wireless TransmittersNote: Please consult individual component installation guides for information.TestLink5A  Set lights in room to desired light level.B  Press and hold “Cal.” for 6seconds.C  Exit room for 5 minutes to complete calibration.Note: When calibration has completed, all lights will flashand begin daylighting.Multiple Daylight Rows (OPTIONAL)For every row of daylighting a separate PowPakR  Dimming Module must be used. For detailed setup  refer to the tuning section of the Radio Powr SavrT Daylight Sensor installation guide.• Select the PowPakR Dimming Module that youwant to adjust by pressing the toggle buttonCalibrate Daylight SensorDaylight Sensor will control all wired fixtu es equally.9Set Occupancy Light LevelsNote: Unoccupied light level is always the minimum light level and cannot be adjusted.A  Set desired occupancy light levels:Use Raise/Lower buttons “ / ” on the PowPak® Dimming Module or Raise/Lower buttons “ /  ” on all associated Pico® Wireless Controls.Note: If certain lights should be unaffected by occupancy, turn lights off using PicoR Wireless Control(s).B  Save occupancy light levels:Press and hold Test button for 6 seconds on any associated Radio Powr SavrTM Occupancy Sensor without a “a” button. Release when Sensor lens starts to flashOr, press and hold “a” button for 6 seconds on any associated Radio Powr SavrTM Occupancy Sensor. Release when Sensor lens  starts to flashNotesDepending on the fixtu e manufacturer or load, low-end and high-end trim may need to be adjusted.• Trim low-end to ensure a stablelight level because some loads willflicker or d op out if trimmed toolow.• Be sure that you can turn on thelights to the low-end trim levelwithout any abnormal operation.• The factory default high-end trimwill normally be sufficient for mosapplications. Trim as desired.FavoriteTroubleshooting  www.lutron.jpBallasts cannot be controlled locally from PowPak® Dimming Module.• Ensure that the breaker(s) to the PowPak® Dimming Module are energized.• Ensure that the PowPak® Dimming Module switched hot lead is wired to the ballast(s).• Ensure that the PowPak® Dimming Module 0 –10 V control lines are wired to the ballast(s).• Reset to factory defaults.Lights do not dim as expected.• Ensure that 0 –10 V control lines are wired properly.• Ensure that fixtu e does not require an inverted signal (10 – 0 V control)Lights do not respond to Wireless Transmitter(s).• Ensure that the breaker(s) to the PowPak® Dimming Module and ballasts are energized.• Ensure that Wireless Transmitters are associated to the PowPak® Dimming Module.• Reset to factory defaults.Wireless Transmitter(s) cannot be associated to PowPak® Dimming Module.• The maximum number of Wireless Transmitters have been associated to the PowPak® DimmingModule. To remove a previously set up Wireless Transmitter, tap a Wireless Transmitter buttonthree times; on the third tap hold for three seconds and then tap three more times.Switched Hot (Yellow)–Hot 1 (Black)To fixtu esControl line to fixtu es*Hot 2 (White)+Hot 2 (White)Junction Box21 mm Knockout OpeningConduit Nut*  Use 0.75 mm2 to 1.5mm2 solid wire onlySuggested Installation Location:Install in center of room.  This ensures proper RF coverage of area.TestLinkCal.Supplied Terminal InformationStrip Length:  9 mmTorque:  2 N•m9 mmTestLink Cal.FCC Information (LMJ- and ULMJ- only)This device complies with part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation. Modifications not expressly approved by Lutron Electronics Co., Inc. could void the user’s authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Re-orient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•••

Navigation menu