Lutron Electronics 0116 Wireless Fixture Sensor User Manual UserManual

Lutron Electronics Company Inc Wireless Fixture Sensor UserManual

UserManual

Download: Lutron Electronics 0116 Wireless Fixture Sensor User Manual UserManual
Mirror Download [FCC.gov]Lutron Electronics 0116 Wireless Fixture Sensor User Manual UserManual
Document ID3385969
Application IDJt35dcmUdCN41KR7r4O8Gg==
Document DescriptionUserManual
Short Term ConfidentialYes
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize132.25kB (1653109 bits)
Date Submitted2017-05-10 00:00:00
Date Available2017-09-30 00:00:00
Creation Date2017-03-08 11:15:51
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2017-03-29 14:44:09
Document TitleUserManual
Document CreatorAdobe InDesign CS6 (Windows)

Required Components
Clear Connect Wireless Fixture
Controllers
One Fixture Control
Part of the Vive Family
PIR lens
041600
Rev. A
03/2017
For each fixture, you will need:
DFCSJ-OEM-OCC Clear Connect Wireless
Wireless Fixture Controller (RF Only)
EcoSystem driver
9.5–20.5 V80-250 mA
Controls up to 4 ballasts or drivers (IEC 60929 Annex E.2 requires each ballast or
driver to limit the sink/source current draw to 2.0 mA maximum).
Driver with self-powered DALI link
Start Here
Wiring Best Practices (for RF consideration)
Install Clear Connect Wireless Fixture Controller
WARNING! Shock Hazard. May result in serious injury or death.
Turn off power at circuit breaker before installing the unit.
•  Ensure knockout and adjacent surfaces are free from burrs, oil, chemicals, debris, etc.
•  Do not push on the PIR lens or button to install the wireless fixture control. Push on the center of the
wireless fixture control.
Connector (poke-in style)
• Keep
all the fixture wiring to the minimum length needed to achieve the connections in an organized manner. Avoid unnecessary slack in the
wires.
•  If the driver is provided with a ground terminal, this terminal must be electrically connected to the grounded fixture metal using a ground wire
that is no longer than 2 in (51 mm).
•  Mechanically affix all the wires to the fixture wall so that they are kept as close possible to the grounded fixture metal.
•  Ensure that the driver wiring is as far as possible from the wiring immediately connected to the wireless fixture control
•  Ensure that the wireless fixture control is mounted away from the LED strips to minimize the coupling of the RF radiation from the LED strips
into the wireless fixture control.
•  For more information, see www.lutron.com/TechnicalDocumentLibrary/048620.pdf
Wireless fixture controller (RF only)
•  18 to 22 AWG (0.75 to 0.3 mm2) solid copper wire
•  Wire strip length: 0.31 in (8 mm)
• The Wireless fixture controller (RF only) (DFCSJ-OEM-RF) can be installed on the back of the fixture, assuming metal tiles are not being used.
•  The Wireless fixture controller (RF only) will be rated for use in plenum areas.
•  Do not fully enclose within the metal fixture.
Mounting Thickness
Snaps enable mounting to the following material thickness ranges:
Mounting to Curved Surfaces
•  0.04 in (1 mm) or less
•  0.041 to 0.08 in (1.1 to 2 mm)
•  0.081 to 0.13 in (2.1 to 3.3 mm)
Mounting directly to a curved surface is not recommended. An adaptor (custom manufactured by the OEM) may be required to ensure that
the device is seated properly.
Remote Mounting
0.04 in (1 mm)
or less
0.041 to 0.08 in
(1.1 to 2 mm)
0.081 to 0.13 in
(2.1 to 3.3 mm)
The wireless fixture control is intended for troffer and linear fixtures and is not intended to be ceiling mounted.
Wiring Diagrams
set-up, programming, and
* For
troubleshooting with a Vive system,
please refer to the installation
instructions included with the Vive hub
or at www.lutron.com
Or
Clear Connect Wireless Fixture
Controller (RF Only)
(DFCSJ-OEM-RF)
Clear Connect Wireless Fixture
Controller (with Occupancy Sensor)
(DFCSJ-OEM-OCC)
UL 2043 Plenum Rated
FCC information and IC information
This device complies with part 15 of the FCC Rules and Industry Canada
license-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) This device may not cause interference, and (2) this
device must accept any interference, including interference that may
cause undesired operation. Modifications not expressly approved by
Lutron Electronics Co., Inc. could void the user’s authority to operate this
equipment.
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
• Re-orient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
•   Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Wireless sensor interface
At least one driver with self-powered DALI link
Clear Connect Wireless Fixture Controllers
English
At least one EcoSystem driver + Wireless Sensor Interface (PS-OEM-2W-UNV)
Button
OR
Fixture Controller (with Occupancy Sensor)
DFCSJ-OEM-RF Clear Connect
Daylight
sensor lens
Button
Please read before installing.
Customer Assistance | 1.844.LUTRON1 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
Daylight
sensor lens
Daylighting Sensor
120 – 277 V~
Wireless sensor interface
Do not install in direct view of the light source or reflecting surface.

S+
SE+
E-
Clear Connect Wireless Fixture Controllers with
Ecosystem or DALI Driver
Clear Connect Wireless
Fixture Controller
E1
E2
EcoSystem / DALI driver
120 – 277 V~
PIR Sensor
•
•
•
•
•
•
•
•
•
Important Notes:
For installation by a qualified fixture manufacturer.
Use copper conductors only.
Check to see that the device type and rating is suitable for the application.
DO NOT install if product has any visible damage.
If moisture or condensation is evident, allow the product to dry completely
before installation.
Operate between 32 °F and 131 °F (0 °C and 55 °C), ambient.
0% to 90% humidity, non-condensing.
For indoor use only.
Sensor should be mounted to fixture in orientation that makes it parallel to
the floor when fixture is installed in ceiling.
Default Functionality
Fixture Controls
Auto On level: DFCSJ-OEM-OCC only
(not applicable for DFCSJ-OEM-VAC or DFCSJ-OEM-RF)
Varies with ambient light level when occupancy is triggered
(e.g., 100% for a dark room, 10% for a bright room).
Timeout period: 15 minutes
For more information, see
www.lutron.com/TechnicalDocumentLibrary/3691039.pdf
Lutron Electronics Co., Inc. 7200 Suter Road
Coopersburg, PA 18036-1299 USA
•  Install in a location that allows the sensor to have an unobstructed view of the area.
•  Install away from radiated heat given off by the light source.

Temperature
Driver with self-powered DALI link
120 – 277 V~
Wireless Fixture Control with Driver with
Self-powered DALI Link
The wireless fixture control is rated for 55 °C (131 °F) maximum. Product must be installed in an area
that will not allow it to exceed this rating. Keep away from heat generating devices (e.g., drivers) and
verify during the fixture design process.
Clear Connect Wireless
Fixture Controller
Release Wires from Connectors
Packaging
Press connector buttons while pushing the wires slightly inward. Pull wires outward to release the wires from the
connectors. Do NOT pull out the wires without using the connector buttons, as damage to the product
can occur.
Fixture packaging must protect the installed wireless fixture control so that it does not get damaged in shipping.
Connector buttons
Clear Connect Wireless Fixture
Controllers
Part of the Vive Family
ALL PROGRAMMING IS OPTIONAL
Programming is not required for default functionality
set-up, programming, and troubleshooting with a
* For
Vive system, please refer to the installation instructions
included with the Vive hub or at
www.lutron.com
  Reset Factory Defaults
Note: In some instances, it may be necessary to reset the
fixture controllers and connected devices back to factory
default settings. Before beginning, make sure that all
devices are connected and powered.
A Rapidly tap the button on the fixture controller three times
and hold on the fourth until the LED begins to flash slowly;
release button.
B Within 1 second of releasing the button, again rapidly
tap the button three times and the LEDs will flash rapidly
indicating that the unit has been reset to factory defaults.
Note: Any associations or programming previously set up
with the fixture control will be erased and will need to be
re‑programmed.
Recommended end-of-line test
1. Provide power to fixture.
2. Fixture will go to the driver’s saved level.
3.   Press the button to toggle the load state. Light will fade to ON
(or OFF) over 1 second. Green LED will stay lit for 2 seconds after
releasing the button.
4.   Toggle the load again (if necessary) to ensure the lights are on.
This will make sure the lights turn ON when power is applied the
next time (at job site).
5. Remove power.
Customer Assistance | 1.844.LUTRON1 USA, Canada, and the Caribbean | +44.(0)20.7702.0657 Europe | +1.610.282.3800 Others | www.lutron.com
Troubleshooting *
Symptom
www.lutron.com
Solution
Sensor does not respond • Sensor requires 2-minute warmup period from power reset before sensing circuit is active.
to motion.
Default timeout is 15 minutes.
Lights do not dim or turn • Ensure that control lines are wired properly
ON as expected.
Lights are unstable at
low‑end.
• Adjust low-end trim. Refer to Vive documentation on www.lutron.com.
If testing occupancy sensor functionality:
1.
2.
3.
4.
5.
Apply power to fixture.
Press button (if necessary) to turn lights off.
Wait for 2 minutes for sensor occupancy circuit to become active
Provide motion in front of sensor - lights will turn ON.
  Lights will not tun off automatically for 15 minutes after last
motion detection.
Limited Warranty: http://www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf
If testing daylight sensor functionality:
1. Apply
power to fixture. Fixture should turn on to full (high end). If
not, press button on sensor.
2.   Shine light source (flashlight) directly into daylight lens. Fixture
light will dim down  over 1 minute (hold flashlight steadily in place).
3.   Cover daylight lens/button with opaque material. Fixture light will
dim up over 1 minute (hold opaque material steadily in place)
Lutron, Pico, PowPak, EcoSystem, and Energi TriPak are trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries. Radio Powr Savr and Vive are trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
©2017 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299 USA

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Create Date                     : 2017:03:08 11:15:51-05:00
Metadata Date                   : 2017:03:29 14:44:09-04:00
Modify Date                     : 2017:03:29 14:44:09-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:7cf66b0f-f5b3-407b-8f0a-c4a65d26a2e8
Original Document ID            : xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0
Document ID                     : xmp.id:1AEFF57B1A04E7118A45AA9DCB8ABDBC
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:19EFF57B1A04E7118A45AA9DCB8ABDBC
Derived From Document ID        : xmp.did:C569E107B666E51185A69EEAA4F3743A
Derived From Original Document ID: xmp.did:B9A671108F48E211AD8DDE0A1DBE8AD0
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2017:03:08 11:15:51-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: JPZ0116

Navigation menu