MANN HUMMEL SPB358 OurAir Duct Air Quality Monitor User Manual
MANN HUMMEL (China) Co., Ltd. OurAir Duct Air Quality Monitor Users Manual
Users Manual
Before Use Warranty and Service Thank you for purchasing a MANN+HUMMEL Duct Air Quality Monitor. Before using the product, please read this operating manual and follow the instructions carefully to prevent any accidents. Scope of Warranty: EN • The product is used according to the instructions in the operating manual; • The product is handled properly according to its intended usage; The MANN+HUMMEL warranty does not apply if the product is damaged due to accidents, errors, normal wear and tear, or inappropriate usage. Please refer to the MANN+HUMMEL website at www.mann-hummel.com for more information or assistance. 19_J05xxx_ SPB 358 E&C.indd 1 9/1/19 5:10 PM Important Information guidelines and instructions below. by the manufacturer or authorized service center in order to avoid hazards. Do not disassemble, repair or alter the device without authorization. Unauthorized disassembly or repair may cause failure and danger. Unauthorized alteration may result in fire or breakdown. Unless under supervision by persons responsible for their safety, persons who are not familiar with the operating instructions, are not allowed to operate the device. If the rated voltage of the product is different from the local standard voltage, do not connect the device to the power source. Otherwise, it may cause damage to the product or fire. The installation place of the device should be stable enough to bear its weight with considering the influence of strong wind, typhoon and earthquake to avoid its falling and the damage it may cause. Parts and components intended for the installation should be used. Do not use parts and components other than those provided in the packaging or recommended. The filter should be used to reduce the occurrence of failures and prolong the service life of duct device, and the filter should be changed after hundreds of hours working. Do not block the air inlets and outlets of the device as it may cause damage to the device. Do not connect the device to power source until all installation work are finished. The max operating temperature of the product is 40°C and shouldn’t be lower than 0°C. Do not use the SPB 358 in dusty environments. Otherwise the sensitivity, accuracy and lifetime of the device will be affected seriously. The sensors and chips used in this device are high tech precision instruments; to minimize interference to the precision components, please prevent the unit from being exposed to high temperature, high humidity, combustible gases and liquids. RF Power (Output power): 16dBm (2412MHz – 2462MHz) Declaration of Conformity This device complies with the essential requirements in Directive 2014/53/EU, and can be used across EU member states or regions. This device complies with part 15 of the FCC Rules (FCC ID: 2AQ3Q-SPB358). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses ,and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/ TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. 19_J05xxx_ SPB 358 E&C.indd 2 9/1/19 5:10 PM 1. Overview EN SPB 358 is a highly integrated air quality monitoring device which could detect multiple parameters of PM2.5, CO2, TVOC, Temperature and Humidity. It could be widely used in the duct air quality monitoring and performance evaluation of ventilation air system and air purifier. Top View Right View No. Description Installation Hole ( 6 mm) Installation Hole ( 8 mm) Wi-Fi Antenna Air Inlet Air Outlet Power Configuration 19_J05xxx_ SPB 358 E&C.indd 3 9/1/19 5:10 PM 2. Installation Caution: Do not use parts and components other than those provided in the packaging or recommended. 2.1 Option 1: Wall-mounting Drill the holes and install the device on the wall through the 2 reserved holes ( 6mm) with expansion screws. Tighten the self-locking nuts to secure the device. Please only use the expansion screws ( 6 mm) provided in the packaging to do the installation. Alternatively, the nylon expansion screws could be used depending on the wall conditions. The schematic is shown below: 6mm 19_J05xxx_ SPB 358 E&C.indd 4 9/1/19 5:10 PM 2.2 Option 2: Ceiling Installation EN The users could use the hanging bolt on-site to install the device on the ceiling through the reserved hole ( 8mm) on the top of the device. Caution: Secure the device through double nuts to prevent sliding. 8mm 19_J05xxx_ SPB 358 E&C.indd 5 9/1/19 5:10 PM 3. Connectivity Connect the power cord to the aviation socket and tighten the lock nut. Caution: Do not force to connect the socket to avoid any damage. 19_J05xxx_ SPB 358 E&C.indd 6 9/1/19 5:10 PM 3.1 Modbus Connection (RS 485) EN Users could transmit data through the reserved 485 communication wire. Before connection, remove the protection layer of a heat-shrinkable tube and 2 wires of yellow and blue color will be shown as below: 3.2 Wi-Fi Connection 1 .After power on, press the “Configuration” button for around 8 seconds to initiate a Wi-Fi hotspot starting with “Ourair_ xxxxxx”. 2. For personal computer or laptop with Windows OS, click on Wi-Fi setting and connect to Wi-Fi of the “OurAir_xxxxxx”; For iOS and Android mobile phone, go to setting and connect to the Wi-Fi of the “OurAir_ xxxxxx”. 19_J05xxx_ SPB 358 E&C.indd 7 9/1/19 5:10 PM 3. Open Internet browser like IE, Firefox, Safari or Chrome. Enter the IP address 10.10.10.1 in the address bar, then we will see the configuration interface for Wi-Fi. 4. Enter Wi-Fi Encryption information and click save to save your settings. The device will restart to complete the Wi-Fi configuration. If the front LED is on, the Wi-Fi is connected successfully. Caution: It will take up to 3 seconds to restart the device. Please do not click on any other commands during reboot to avoid errors. 19_J05xxx_ SPB 358 E&C.indd 8 9/1/19 5:10 PM 4. On-Boarding with the OurAir App EN 4.1 Download the OurAir App 1 For Android users, go to Google Play store to search and download the mobile app “OurAir” or scan the QR-code. 2 For iPhone users, go to App store to search and download the mobile application “OurAir” or scan the QR-Code. 3 For China Android users, go to Tencent store to search and download the mobile application “OurAir” or scan the QR-Code. 19_J05xxx_ SPB 358 E&C.indd 9 9/1/19 5:10 PM 4.2 Adding the SPB 358 device to your account 1. Log-in to the OurAir App only by Email 10 19_J05xxx_ SPB 358 E&C.indd 10 9/1/19 5:10 PM 2. Adding device to your account EN Ways to add your first OurAir device 2.1 – After you’ve logged in successfully for the first time, you can select the device that you want to add 2.2 – Alternatively, you can go to the settings of OurAir App and tap the “+” symbol to add new device 2.3 – You can also add the device at home screen (if no device was added previously) 11 19_J05xxx_ SPB 358 E&C.indd 11 9/1/19 5:10 PM 3. Pair a device with the OurAir App Scan the QR code with OurAir App to pair the device. 12 19_J05xxx_ SPB 358 E&C.indd 12 9/1/19 5:10 PM 5. Clock Module Configuration EN Caution: consult the dealers or professionals to open the front cover of the device to set the timer. The interior structure of the device is as shown below: Digital Screen Clock Module Transformer Air Pump K1 K2 K3 Test Cabin 5.1 The 4 modes of the clock module P1: To set the daily working period of device. E.g. The device automatically start working at 7:30 am and shut down at 5 pm daily (Select the P1 mode, enter the numeric value of 0730 and 1700 in turn). P2: To set the pulse signal. It is not recommended for common users. Consult the dealers or professionals if needed. P3: To set the date and month on which the device will start to work and shut down. E.g. The device automatically start working on 1st Oct and shut down on 25th Dec (Select P3 mode, enter the numeric value of 1001 and 1225 in turn). P4: To set the local date and time. E.g. The SPB 358 device is used in Germany, and the local date & time is 15th Jun, 2:15pm (Select P4 mode, enter the numeric value of 0615 and 1415 in turn). 13 19_J05xxx_ SPB 358 E&C.indd 13 9/1/19 5:10 PM 5.2 Functions of the buttons on the clock module K1: To select the mode. K2: To enter the mode or confirm the numeric value input. K3: To adjust the numeric value. Press K1 for around 2 seconds to activate the mode selection. Continue to press K1 shortly to select the specific mode from P1 to P4. Enter K2 to confirm the selected mode, and the digital screen will start to flicker waiting for the numeric value input. Press K3 to enter the numeric value of you desired to key in, and then press K2 to confirm the values input. Caution: The default time zone of the clock module is set at UTC+8, and the working time is from 7:00 am to 7:00 pm daily. Caution: When setting the numeric values, the first two digits of the nixie start to flicker. 14 19_J05xxx_ SPB 358 E&C.indd 14 9/1/19 5:10 PM 6. Product Specification and Packaging EN Packaging list Items Qty Packaging box SPB 358 unit Power cable Power adapter (if any) Sampling tube (8mm OD x 5mm ID) Sampling connector & washer Expansion screw M6 (stainless steel) Expansion screw (nylon) Nut (for hanging bolt) Operating manual Warranty card Quality card 15 19_J05xxx_ SPB 358 E&C.indd 15 9/1/19 5:10 PM Product Specification Certification RESET™ (Grade B), RoHS,CE,FCC Net Weight 3 Kg Dimensions 265mm x 185mm x 95mm Input Voltage 100-240V AC Rated Voltage 24V DC Rated Current 1A Connectivity Wi-Fi (2.4GHz) / Modbus Air quality parameters measured PM2.5 (0-500 μg/m3) CO2 (400 – 2000 ppm) TVOC (125 – 600 ppb) Temperature (0 – 40 °C) Rel. Humidity (0 – 99 % RH) Sampling frequency 1 min Peak Air Flow 2.2 l/minute Average Air Flow 2 l/minute Air Pump Vacuum Degree 75 KPa Air Pump Negative Pressure ≈ -24 KPa Sensor calibration frequency* 12 Months *Offered as part of OurAir service package. 7. Environment Please play a part in preserving the environment by not discarding the indoor air quality monitor with usual household waste at the end of its lifespan. Please bring it in to a recycling collection point instead. 16 19_J05xxx_ SPB 358 E&C.indd 16 9/1/19 5:10 PM
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 16 Language : zh-CN Tagged PDF : Yes XMP Toolkit : 3.1-701 Producer : Microsoft® Word 2016 Creator : yangcj.DST Creator Tool : Microsoft® Word 2016 Create Date : 2019:02:21 13:30:50+08:00 Modify Date : 2019:02:21 13:30:50+08:00 Document ID : uuid:2C2EC115-FABE-4DF5-B288-9AB9602E0355 Instance ID : uuid:2C2EC115-FABE-4DF5-B288-9AB9602E0355 Author : yangcj.DSTEXIF Metadata provided by EXIF.tools