MOJIX CBLENODE3K Star 3000 System User Manual USERMANUAL STAR3000 2 0 1x
MOJIX, Inc. Star 3000 System USERMANUAL STAR3000 2 0 1x
MOJIX >
Contents
- 1. Users Manual Part 1
- 2. Users Manual Part 2
- 3. Users Manual Part 3
- 4. Users Manual Part 4
- 5. Users Manual Part 5
Users Manual Part 5
STAR 3000 Installation Manual MASTER CONTROLLER INSTALLATION The Mojix Master Controller (MCON) is an application server capable of running on a number of platforms to support the Mojix STAR system. The MCON is built on a scalable architecture that allows seamless coordination and aggregation of an entire network of distributed STAR systems across one or multiple facilities. Its applications include a Real Time Location System (RTLS) and portal or dock door operations which provide transition detection and rejection of closely staged RFID tags. The MCON’s RTLS function uniquely identifies and locates items in real-time and is able to handle extensive data collection requirements with a high level of accuracy. The MCON publishes tag data directly to enterprise applications via EPC ALE without the need of middleware typically used to collect and filter tag information. The diagram below provides a summary of the MCON’s interfaces, functions and applications. EC Specs Configuration Configuration & Status Web UI Configuration & Status MySQL DB EC Reports ALE Configuration & Status Loc / DDD / SensorAct / ReportRules / StatusHealth Star Link DDD / Loc / Sensors Results Raw Tag Data / Tag Results / Star Commands Star Driver Spread bus Raw Tag Data / Star Commands Figure 18: MCON Architecture The MCON is offered in a high-availability platform with a robust redundancy capability within the hardware components of the MCON, as well as for automatic failover redundancy of an entire MCON to secondary system. Internally, the MCON features hot-swap power supplies and six (6) hot-swap hard drives running in a RAID5 configuration, which allows for a single drive failure without disruption of any MCON functions. Replacement drives need only be inserted in place of the failed drive for the system to fully recover. The MCON is offered in two form factors detailed in Table 8 and Table 9. The desktop configuration is suitable for small installations, demonstrations and trial implementations. The enterprise configuration is intended for full scale deployments. Mojix Incorporated www.mojix.com (877) 886-6549 Page 25 of 36 Confidential and Proprietary STAR 3000 Installation Manual Part Number: MCN-1000-T Form Factor: Tower Processors: Quad-core Intel® Xeon® 3400 series Cache: 8MB Memory: 8GB DDR3 1333MHz RAID Controller: SATA RAID Controller Drives: Two 3.5" SATA drives Communications: Single Port 1GbE NIC Power Supply: Single cabled power supply (305W) Video: Matrox G200eW w/ 8MB memory Operating Systems: CentOS 5.5 and 5.7, Redhat Enterprise 5.5 and 5.7 Table 8: MCON Desktop Server Specification Part Number: MCN-1000-R Form Factor: 1U rack height Processors: Dual Six-core Intel® Xeon® 5600 series Cache: 8MB Memory: 16GB DDR3 1333MHz RAID Controller: SAS RAID Controller Drives: 8 hot-plug 2.5” SAS (15K RPM) 73GB; One DVD ROM SATA Communications: Four Broadcom NetExtreme II Gigabit Ethernet NIC interfaces Power Supply: Two hot-plug high-efficient 502W Energy Smart Redundant Video: Integrated Matrox G200, 8MB shared video memory Operating Systems: CentOS 5.5 and 5.7, Redhat Enterprise 5.5 and 5.7 Table 9: MCON Enterprise Class Server Specification Mojix Incorporated www.mojix.com (877) 886-6549 Page 26 of 36 Confidential and Proprietary STAR 3000 Installation Manual Alternatively, the MCON is also offered as a virtual machine that satisfies the same configuration as the two hardware platforms. These specifications are detailed in Table 10 and Table 11. Hard Disk : 20 GB Processors : Processors Class : Intel Xeon 5600 series Memory : 6 GB + RTLS Memory Class : DDR3 1333MHz Operating Systems : VM Ware VSphere Compliant Guest OS : CentOS 5.5 and 5.7, Red Hat Enterprise 5.5 and 5.7 Table 10: MCON Virtual Machine Specification – Desktop Class Hard Disk : 20 GB Processors : Processors Class : Intel Xeon 5600 series Memory : 8 GB + RTLS Memory Class : DDR3 1333MHz Operating Systems : VM Ware VSphere Compliant Guest OS : CentOS 5.5 and 5.7, Red Hat Enterprise 5.5 and 5.7 Table 11: MCON Virtual Machine Specification – Enterprise Class A processor is defined as a single computing component that cannot be split into any smaller computing units. A multi-core CPU may be composed of several smaller computing units. - The minimum amount of memory required is calculated by the RTLS resource allocation specification provided below. MCON hardware must be installed in a temperature and environmentally controlled room. Redundancy Summary The Mojix solution includes a robust redundancy capability within the hardware components of the Master Controller (MCON), as well as for automatic failover redundancy of an entire MCON system to another. These redundancy options are only offered on the Enterprise Server Class hardware. Internally, the platform features 8 hot-swap hard drives running in a RAID5 configuration. With this configuration, a single drive can fail without disrupting any MCON functions. Replacement drives need only be inserted in place of the failed drive and the system will automatically configure the new drive. Figure 19: Front Panel of Dell PowerEdge Server Mojix Incorporated www.mojix.com (877) 886-6549 Page 27 of 36 Confidential and Proprietary STAR 3000 Installation Manual The system also features hot-swap power supplies. It is recommended that each supply use a separate AC circuit to protect against a possible circuit failure. Figure 20: Redundant Power Supplies Once the MCON hardware is mounted and secured and prior to issuing power to the unit, connect a network cable to the eth0 port as identified in Figure 21. The next step is to power on the unit. Figure 21: Identification of Network Interfaces Mojix Incorporated www.mojix.com (877) 886-6549 Page 28 of 36 Confidential and Proprietary STAR 3000 Installation Manual SYSTEM NETWORK SETUP The MCON has the flexibility to configure and manage the STAR unit through a Web enabled interface called the Web Console. CONNECTING TO THE MCON The MCON by default uses DHCP for IP assignment. If a DHCP server is not found within 5 minutes from power up, the MCON uses the following default IP address. • Default Static IP: 169.254.1.1 • Default Netmask: 255.255.0.0 • Default Gateway: 169.254.1.1 It is recommended to connect the MCON using loopback/crossover cable directly to a windows PC for the initial setup. This will ensure that the MCON defaults to the IP address above after 5 minutes. If the MCON is instead connected to a LAN with DHCP server, it may acquire a different IP address, making it difficult to locate on the network for first time setup. CHANGING MCON NETWORK SETTINGS The simplest way to change network settings of the MCON is to navigate a web browser to the MCON’s IP address. Use the following credentials to authenticate the connection. User: edison Password: m0j1xInc Once connected, use the Config menu to select Network. The Figure 22 shows the network configuration screen. The user can choose between dhcp or a static IP address. Once changes are made, click on the Save button. Changes occur within 30 seconds. Mojix Incorporated www.mojix.com (877) 886-6549 Page 29 of 36 Confidential and Proprietary STAR 3000 Installation Manual Figure 22: MCON Network Configuration CHANGING STAR NETWORK SETTINGS The STAR 3000 uses DHCP for IP addressing by default. If a DHCP server is not detected within 1 minute from power up, then there are 2 temporary IP addresses assigned and remain active for 10 minutes. These addresses are as follows: • Default Ethernet 1 Address: 169.254.1.10 • Default Ethernet 1 Netmask: 255.255.0.0 • Default Ethernet 2 Address: 169.254.1.11 • Default Ethernet 2 Netmask: 255.255.0.0 Network settings can be edited and changed using a built-in Web interface. To edit the network configuration, follow this procedure: 1. Power on the STAR 3000 with an Ethernet cable connected to Ethernet 1. 2. Enter the default IP address of 169.254.1.10 into a Web browser and the user should be presented with a page similar to Figure 23. Mojix Incorporated www.mojix.com (877) 886-6549 Page 30 of 36 Confidential and Proprietary STAR 3000 Installation Manual Figure 23: STAR Web UI Network Setup 3. Click on the Configuration Interface link and the user is presented with a web page as depicted in Figure 24. Mojix Incorporated www.mojix.com (877) 886-6549 Page 31 of 36 Confidential and Proprietary STAR 3000 Installation Manual Figure 24: STAR Web UI Network Configuration Page 4. Select the desired IP settings for Ethernet 1 and then click save. This will reboot the STAR which will take approximately 2 minutes. Mojix Incorporated www.mojix.com (877) 886-6549 Page 32 of 36 Confidential and Proprietary STAR 3000 Installation Manual MCON CONFIGURATION Please refer to the user interface guide document: USERGUIDE-MCON-WebInterface for detailed instructions. Mojix Incorporated www.mojix.com (877) 886-6549 Page 33 of 36 Confidential and Proprietary STAR 3000 Installation Manual APPENDIX A: FCC NOTICE, STAR 3000 AND ENODE CAUTION: To comply with FCC RF exposure compliance requirements, a separation distance of 20 cm must be maintained between the antenna of this device and all persons. WARNING: This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction's manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. In order to ensure compliance with FCC regulations, shielded and grounded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user's authority to operate this equipment. Mojix Incorporated www.mojix.com (877) 886-6549 Page 34 of 36 Confidential and Proprietary STAR 3000 Installation Manual APPENDIX B: FCC NOTICE, EMUX WARNING: This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction's manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense. The user is cautioned that changes and modifications made to the equipment without approval of the manufacturer could void the user's authority to operate this equipment. Mojix Incorporated www.mojix.com (877) 886-6549 Page 35 of 36 Confidential and Proprietary STAR System User Manual Mojix Incorporated 11075 Santa Monica Blvd., Suite 350 Los Angeles, CA 90025 Web: www.mojix.com Tel: (877) 886-6549 6549 E-mail: service@mojix.com Need More Help? Our product support team is comprised of individuals highly experienced in RFID deployments across a broad spectrum pectrum of application and use cases. If you are an existing customer of Mojix, please login to the secure area and submit a service request if you have additional questions. If you are unable to login, then please send us an email at: service@mojix.com. Mojix Incorporated www.mojix.com (877) 886-6549 Page 36 of 36 Confidential and Proprietary
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Gus Mendoza Create Date : 2012:11:20 09:02:54-08:00 Modify Date : 2012:11:20 09:03:04-08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2012:11:20 09:03:04-08:00 Creator Tool : PrimoPDF http://www.primopdf.com Format : application/pdf Title : Microsoft Word - USERMANUAL-STAR3000-2 0 1.docx Creator : Gus Mendoza Document ID : uuid:6b0118f7-0c07-43a4-ba06-8799222f9506 Instance ID : uuid:506809cd-470d-4589-a236-d752e8dbf9da Producer : Nitro PDF PrimoPDF Page Count : 12EXIF Metadata provided by EXIF.tools