MOTOTECH MT-FOL01 Transmitter Assy - Folding Key User Manual
MOTOTECH Co., Ltd. Transmitter Assy - Folding Key
MOTOTECH >
User Manual
Vehicle Name: C210 DEPARTMENT: R&D CENTER TITLE : SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION PAGE : STANDARD SPECIFICATION PART NUMBER : MT-C210-0107 1 / 11 TRANSMITTER ASSY – Standard Specification -- TABLE OF CONTENTS -1. APPLICATION 1.1 SUMMARY 2. ELECTRCAL PERFORMANCE 2.1 GENERAL ELECTRICAL PERFORMANCE OF TRANSMITTER ASS' Y 2.2 WIRELESS CHARACTERISTIC 2.3.1 DOMESTIC (DOM) 2.3.2 GENERAL EXPORT(EXP) 3. FUNCTION 3.1 STRUCTURE OF DATA ( "1", "0" ) 3.2 TRANSMITTER PROTOCOL FORMAT 3.3 BUILDING THE TRANSMITTED CODE WORD (ENCODER) 3.4 BASIC OPERATION OF RECEIVER (DECODER) 3.5 SYNCHRONIZATION WINDOW 3.6 LED FLICKERING PROCEDURE 3.7 RADIO FREQUENCY TRANSMISSION PROCEDURE 3.8 REMOCON FUNCTION OF EACH SIGNAL 3.9 POWER ON INITIALIZATION 4. OPERATING 4.1 REMOTE DOOR LOCK 4.2 REMOTE DOOR UNLOCK 4.3 PANIC FUNCTION 4.4 ESCORT FUNCTION(DOM ONLY) 4.5 ID CODE 4.6 REMOCON RESPONSE OF OPERATING CONTINUOUS SWITCH 5. REVISION LIST 5.1 REVISION SP01 (2013-01-07) 3. 2. REV.SP01 MARK EO NUMBER REVISION DATE 2013.01.07 ORIGINAL DATA MANAGEMENT DEPARTMENT ORIGINAL RELEASE CHANGING LIST REFERENCE DATA 1 ~ 11 PAGE DIVISION WRITER POSITION APPROVAL 13.01.07 CHAGING DATE REVIEWER KIM.H.J WRITER APPROVER SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- PAGE: 2 / 11 (SHT/SHTS) 1. APPLICATION THIS SPEC APPLIES TO C210 IMMO & BCM Transmitter ASS’Y. BUT, IF CONTENT WHAT IS DIFFERENT THIS SPEC EXIST, CONTENTS OF DRAWING SHEET IS FIRST OF ALL 1.1 SUMMARY WHEN USER CONTROL SWITCH OF TRANSMITTER ASS’Y, DATA FORMAT OF“VEHICLE CONTROL MESSAGE” IS TRANSMITTED TO BCM BY TRANSMITTER’S CPU, AND THEN WHEN BCM RECEIVE THAT MESSAGE, BCM’S CPU CONSIDER TO CONTROL VEHICLE 열쇠고리 PANIC BUTTON UNLOCK BUTTON LOCK BUTTON RELEASE BUTTON KEY BLADE PICTURE 1. Transmitter EACH SWITCH FUNCTIONS IS SAME TO TABLE 1.1 TABLE 1.1 FUNCTION LOCK BUTTON EACH SWITCH FUNCTIONS OF TRANSMITTER SWITCH FUNCTION DOOR LOCK ESCORT (DOM ONLY) SHORT PRESSING LOCK BUTTON UNDER 0.5s - LED flicker only once as long time LONG PRESSING LOCK BUTTON OVER 0.5s - LED flicker twice as short time UNLOCK BUTTON DOOR UNLOCK SHORT PRESSING UNLOCK BUTTON UNDER 0.5s - LED flicker only once as long time PANIC BUTTON PANIC LONG PRESSING PANIC BUTTON OVER 2s - LED flicker twice as short time SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 페이지: 3 / 11 (SHT/SHTS) 2. ELECTRICAL PERFORMANCE 2.1 GENERAL ELECTRICAL PERFORMANCE OF TRANSMITTER ASS' Y LIST REQUIREMENTS RATED VOLTAGE DC 3.0V OPERATING VOLTAGE RANGE OPERATING TEMPERATURE RANGE STORED TEMPERATURE RANGE INSULATION RESISTANCE USING DATE DARK CURRENT NOTE DC 2.7V ~ DC 3.3V -10℃ ~ +60℃ NORMAL OPERATING TEMPERATURE RANGE FOR OPERATING -20℃ ~ +70℃ IT DOESN’T EXISTED FEBRILITY OR IGNITION BY LEAKAGE CURRENT USING ONE DAY PER 10 TIMES, OVER 2 YEARS PCB MOISTUREPROOFING AND DEFINE WITH INSULATION ELECTRONIC COMPONENTS COATING REQUIRED UNDER 1uA 2.2 WIRELESS CHARACTERISTIC 2.3.1 DOMESTIC (DOM) (1) TRANSMIT FREQUENCY: 433.92MHZ ± 10KHZ(@ ROOM TEMPERATURE) (2) CLEAR FREQUENCY BAND WIDTH: 13kHz ± 5kHz (3) OUTPUT: 3.981 mW UNDER (6dBm) (4) MODULATION METHOD: FM MODULATION (5) COMMUNICATION METHOD: HALF DUPLEX METHOD 2.3.2 GENERAL EXPORT (EXP) (1) (2) (3) (4) (5) TRANSMIT FREQUENCY: 433.92MHZ ± 10KHZ(@ ROOM TEMPERATURE) CLEAR FREQUENCY BAND WIDTH: 13kHz ± 5kHz OUTPUT: 3.981 mW UNDER (6dBm) MODULATION METHOD: FM MODULATION COMMUNICATION METHOD: HALF DUPLEX METHOD FCC (Federal Communications Commission) WARNING: This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. This device complies with Part 15 of the FCC`s Rules. Operation is subject to the following two Conditions: 1. This device may not cause harmful interference, and 2. This device must accept ant interference received, including interference that may cause undesirable operation. SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 3. FUNCTION 3.1 STRUCTURE OF DATA (“1", "0”) 3.2 TRANSMITTER PROTOCOL FORMAT (1) 송신부의 1회 DATA 전송횟수는 10FRAME으로 구성된다. (1) ONE TIME TRANSMITTING DATA CONSIST OF 10 FRAMES (2) 각 FRAME간 전송 간격은 6.8 ± 1ms로 한다. (2) EACH FRAME DATA THANSMISSION INTERVAL IS 6.8 ± 1ms (3) 모든 0과 1의 BIT 형태는 PULSE 형태로 구별한다. (3) ALL OF BIT (0 AND 1) DIFFERENTIATE THE PULSE FORM (4) CODE WORD TRANSMISSION SEQUENCE (73.6msec) (5) TRANSMISSION FORMAT (MANCHESTER) 페이지: 4 / 11 (SHT/SHTS) SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 페이지: 5 / 11 (SHT/SHTS) (6) CODE WORD TRANSMISSION DATA FORMAT (7) RF Data Format (756msec) ① Preamble: 16BIT CONSIST OF “0” ② Header: CONSIST OF Low Level FOR 4TE(Timing Element) ③ Start Bit: 1Bit CONSIST OF “1” ④ Encrypted Portion: CONSIST OF 32Bit (TABLE 3-1) ⑤ Fixed Code Portion: CONSIST OF 32Bit (TABEL 3-2) Bit Address 0 ~ 15 16 ~ 17 18 ~ 19 20 ~ 21 22 23 24 ~ 27 28 ~ 31 TABLE 3-1 Encrypted Portion Information Description Values Synchronization Count Synchronization Counter Value Counter 00- TE= 100 us BSEL_0, 01- TE= 200 us Bit rate select BSEL_1 10- TE= 400 us * 11- TE= 800 us 00- 1 Minimum number of code 01- 4 MTX_0, MTX_1 words 10- 10 * 11- 16 00- 0 ms (1 TE) GUARD_0, 01- 6.8 ms + 2 TE * Guard time select GUARD_1 10- 25.6 ms + 2 TE 11- 76.8 ms + 2 TE 0 = PWM MOD Modulation Format 1 = MANCHESTER * 0 = Short Header, TH = 4 x TE * HEADER Header Length 1 = Standard Header, TH = 10 x TE Not Used S3, S2, S1, S0 = DOOR LOCK S3, S0, S1, Button Status = DOOR UNLOCK S2 = PANIC = ESCORT Field SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION Bit Address 32 ~ 55 SPEC NO: ES- 페이지: 6 / 11 (SHT/SHTS) TABLE 3-2 Fixed Portion Information Field Description ID0 ~ ID23 Serial Number 56 ~ 59 0 0 1 0 60 ~ 63 S3, S3, S0, S1, S2 Button Status 3.3 BUILDING THE TRANSMITTED CODE WORD (ENCODER) 3.4 BASIC OPERATION OF RECEIVER (DECODER) 3.5 SYNCHRONIZATION WINDOW Values S2, S1, S0 DOOR LOCK DOOR UNLOCK PANIC ESCORT SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 3.6 LED FLICKERING PROCEDURE LED FLICKERING PERFORM ON/OFF PROCEDURE TABLE 3-3 LED TURNED THE LIGHT ON TIME BY EACH FUNCTION 3.7 RADIO FREQUENCY TRANSMISSION PROCEDURE TABLE 3-4 TX TRANSMISSION FLOW CHART START 스위치 분석 NO(NOISE ...) 스위치 입력 OK YES TX POWER = 1(ON) LED = ON TX DATA 출력(2.5Kbit/s) LED = OFF TX POWER = 0(OFF) END 페이지: 7 / 11 (SHT/SHTS) SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 페이지: 8 / 11 (SHT/SHTS) 3.8 REMOCON FUNCTION OF EACH SIGNAL TABLE 3-8 REMOCON FUNCTION OF EACH SIGNAL SYMBOL SIGNAL NAME VSS GND RA0 LOCK RA1 UNLOCK RA2 Not Used RC0 POWER CON RC1 Not Used RC2 TX DATA RC3 PA CON RC4 LED RC5 Not Used /MCLR RESET RA4 PANIC RA5 Not Used VDD BAT I/O (PIN NO) POWER ( 14 ) INPUT ( 13 ) INPUT ( 12 ) ( 11 ) OUTPUT ( 10 ) ( 9 ) OUTPUT ( 8 ) OUTPUT ( 7 ) OUTPUT ( 6 ) ( 5 ) INPUT ( 4 ) INPUT ( 3 ) ( 2 ) POWER ( 1 ) CONTENTS OPERATING NOTE Ground HIGH: PRESSING - SHORT PRESSING - DOOR LOCK - LONG PERSSING - ESCORT HIGH: PRESSING - SHORT PRESSING - DOOR UNLOCK POWER DOWN MODE OUTPUT WHEN OPERATING FINISH, IT IS SLEEP MODE Spare IO Port Spare IO Port RF DATA OUTPUT DATA OUTPUT ABOUT SWITCH INPUT 625Hz RF PA OUTPUT POWER AMP CONTROL 736ms LOW: LED ON Data OUTPUT Display Spare IO Port WHEN POWER TURN ON, IT RESET HIGH: PRESSING - LONG PRESSING - PANIC Spare IO Port Spare IO Port BAT POWER SUPPLY - POWER SUPPLY TO MICOM NORMAL : 2.1V < BAT < 3.5V 3.9 POWER ON INITIALIZATION (1) DEFINE ABOUT ALL OF I/O (INPUT/OUTPUT) PINS (2) WHEN CPU CHANGE FROM POWER DOWN MODE TO ACTIVE MODE, DEFINE EACH PORT’S CONDITION SYMBOL PIN NO I/O CONDITION VDD POWER HIGH RA5 RA4 INPUT HIGH /MCLR INPUT HIGH RC5 RC4 OUTPUT RC3 OUTPUT CONTENTS SYMBOL PIN NO I/O CONDITION CONTENTS RC2 OUTPUT DATA RC1 Not Used RC0 10 OUTPUT HIGH HIGH ON RA2 11 Not Used Not Used RA1 12 INPUT HIGH LOW LOW ON RA0 13 INPUT HIGH HIGH HIGH ON VSS 14 POWER LOW Not Used HIGH PERCEIVING LOW PERCEIVING HIGH PERCEIVING HIGH PERCEIVING Ground SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 페이지: 9 / 11 (SHT/SHTS) 4. OPERATING 4.1 REMOTE DOOR LOCK WHEN SWITCH OF TRANSMITTER PRESSE UNDER 0.5s, IT PERFORM VEHICLE’S DOOR LOCK FUNCTION (1) AFTER SWITCH PRESSING (PRESSING TIME = 0.1 ~ 0.5s), IMMEDIATELY TRANSMITTER IS POWER ON AND TRANSMIT DATA (2) DURING MICOM TRANSMIT DATA, IF BUTTON INPUT ENTER, MICOM IGNORE THAT SIGNAL AND IT PERFORM EXISTING OPERATING (3) IF SWITCH PRESSING TIME IS UNDER 0.1s, MICOM IGNORE THAT SIGNAL (4) WHEN ALL OF OUTPUT COMPLETING, IF NOTHING HAPPENS WITHIN 20 ± 5ms, IT WILL BE ENTERED “POWER DOWN MODE” 4.2 REMOTE DOOR UNLOCK WHEN SWITCH OF TRANSMITTER PRESS UNDER 0.5s, IT PERFORM VEHICLE’S DOOR UNLOCK FUNCTION. (1) AFTER SWITCH PRESSING (PRESSING TIME = 0.1 ~ 0.5s), IMMEDIATELY TRANSMITTER IS POWER ON AND TRANSMIT DATA (2) DURING MICOM TRANSMIT DATA, IF BUTTON INPUT ENTER, MICOM IGNORE THAT SIGNAL AND IT PERFORM EXISTING OPERATING (3) IF SWITCH PRESSING TIME IS UNDER 0.1s, MICOM IGNORE THAT SIGNAL. (4) WHEN ALL OF OUTPUT COMPLETING, IF NOTHING HAPPENS WITHIN 20 ± 5ms, IT WILL BE ENTERED “POWER DOWN MODE” 4.3 PANIC FUNCTION WHEN SWITCH OF TRANSMITTER PRESS OVER 2s, IT PERFORM VEHICLE’S PANIC FUNCTION. (1) IF SWITCH IS PRESSED LONGER THAN 2s, AT THE SAME TIME, TRANSMITTER IS POWER ON AND TRANSMIT DATA (2) DURING MICOM TRANSMIT DATA, IF BUTTON INPUT ENTER, MICOM IGNORE THAT SIGNAL AND IT PERFORM EXISTING OPERATING (3) WHEN ALL OF OUTPUT COMPLETING, IF NOTHING HAPPENS WITHIN 20 ± 5ms, IT WILL BE ENTERED “POWER DOWN MODE” SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 페이지: 10 / 11 (SHT/SHTS) 4.4 ESCORT FUNCTION (DOM ONLY) WHEN SWITCH OF TRANSMITTER PRESSE OVER 0.5s, IT PERFORM VEHICLE’S ESCORT FUNCTION (1) IF SWITCH IS PRESSED LONGER THAN 0.5s, WHEN THE TIME BECOME 1s, TRANSMITTER IS POWER ON AND TRANSMIT DATA (2) DURING MICOM TRANSMIT DATA, IF BUTTON INPUT ENTER, MICOM IGNORE THAT SIGNAL AND IT PERFORMS EXISTING OPERATING. (3)WHEN ALL OF OUTPUT COMPLETING, IF NOTHING HAPPENS WITHIN 20 ± 5ms, IT WILL BE ENTERED “POWER DOWN MODE” (4) LED IS NOT OPERATING 4.5 ID CODE (1) RECEVING THE SAME ID CODE NOT ONLY TRANSMITTER, BUT ALSO BCM ID CODE IS CONTROLED VEHICLE BY WIRELESS, SO TO MAINTAINED ACCURATE VEHICLE OPERATION AND TO PREVENTED MALFUNCTION OF VEHICLE BYINTERFERENCE ARE VERY IMPORTANT , THEREFORE IT MUST BE CHOSEN CAREFULLY IN TERM OF A THEFT OF THE VEHICLE AND THE USER’S SATISFACTION AND POST-MANAGEMENT (2) ID CODE COMPOSITION ID CODE IS WHAT CONBINE “24 MULTIPLIER OF 2” CODE 4.6 REMOCON RESPONSE OF OPERATING CONTINUOUS SWITCH (1) WHEN SWITCH IS PRESSING, IT BASICALLY TRANSMIT 10 FRAME (2) DURING TRANSMIT 10 FRAMES, IF THE SWITCH PRESSES SEVERAL TIMES, MICOM IGNORE CONTINUOUS SWITCH AND PERFORM EXISTING TRANSMISSION (3) EXISTING SWITCH OPERATING IGNORE NEXT SWITCH OPERATING SSANGYONG MOTOR COMPANY STANDARD SPECIFICATION SPEC NO: ES- 5. REVISION LIST 5.1 REVISION SP01 (2008-09-01) (1) LIST : 3-2의 6) CODE WORD TRANSMISSION (2) NOT USED RANGE OF Fixed Code Portion : 0001 => 0010 5.1 REVISION SP01 (2013-01-07) (1) LIST: ORIGINAL RELEASE 페이지: 11 / 11 (SHT/SHTS)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Create Date : 2013:04:24 13:58:35+09:00 Modify Date : 2014:09:26 14:56:25+09:00 Metadata Date : 2014:09:26 14:56:25+09:00 Producer : doPDF Ver 7.2 Build 373 (Windows XP Professional Edition (SP 2) - Version: 5.1.2600 (x86)) Format : application/pdf Document ID : uuid:aa0e1c1b-9c91-44f4-970d-7546f107675d Instance ID : uuid:6d292a18-7ea5-43ba-86b1-a9577224ae38 Page Layout : OneColumn Page Mode : UseNone Page Count : 11EXIF Metadata provided by EXIF.tools