MUL T LOCK TECHNOLOGIES ENTRRC00 ENTR Remote Control User Manual ENTRR Fingerprint Reader FCC IC
MUL-T-LOCK TECHNOLOGIES LTD ENTR Remote Control ENTRR Fingerprint Reader FCC IC
Contents
- 1. Users Manual-Part 1 (1-20).pdf
- 2. Users Manual-Part 2 (21-35).pdf
- 3. Users Manual-Part 3_rev.pdf
Users Manual-Part 1 (1-20).pdf
Y I ENTR‘ I EMUL-T-LDCK' m: Table of Content 1. Cylinder Installation 5 1.1 Package Content 5 1.2 Tools Requirements ............................................................... 5 1.3 Prior to Installation ................................................................ 6 1.4 Cylinder & Unit Installation ................................................................... 6 1.5 Magnet Fitting ............ 8 2. ENTR® Description 9 2.1 ENTRG’ Description .............................................................. 9 2.2 Indications .............................................................................................................................. 9 2-3 0N/0FF Switch ............................................................................................................................. 10 2.3.1 Switching the ENTRQ 0N .......................................................... 10 2.3.2 Switching the ENTR‘B7 OFF .......................................... . 10 2.33 Low Battery Indication .............................................................. 10 2.4 Initiating the Lock ................................................................. 11 2.5 Default PIN Code 11 3- Operation ..................................................................... 12 3.1 Changing PIN Code VVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVV 12 3.2 Door Configuration .............................................................. 13 3.3 Pairing Remote Control ................................................................................................................... 16 3.4 Deleting Remote Control .............................................................. 17 3.5 Setting the Sound Signal. .................................................. 18 3.6 Setting Locking Mode .............................................................. 19 3-7 Operated by Knob. .............................................................. ..20 3.8 Operated by Slide Buttons 20 II ENTR® Dead Bolt User Manual T I ENTR‘ I .MUL-T-Locn' mm; mm 4. Touchpad Reader 21 4.1 Changing PIN Code .............................................................. 21 4-2 Battery Replacement . .......................................................... 21 42.1 Low Battery Indication ...................................................... 21 5. Touchpad Reader Operation 22 5.1 Operation. 5.2 Pairing Touchpad Reader ............................................................... 22 5-3 Touchpad Reader Master PIN Code .......................................... 24 5.4 Menu Mode. ....................................................... 24 5.5 Adding Personal User Code ................................................. 24 5.6 Open Door ................................................................ 25 5.7 Lock Door ............................................................... 25 5.8 Delete Personal User Code .. ............................................. 25 5.9 Delete All Personal User Codes ...................................... 25 5.10 Volume Control 26 5.11 Factory Reset 25 6- Fingerprint Reader . ...................................................... 27 6.1 Mounting the Fingerprint Reader V ............................... 27 62 Battery Replacement .. .......................................................... 27 6.3 Adjust Date & Time 27 6.4 Pairing Fingerprint Reader ............................................................. 28 6.4.1 Add Master ....................................................................... 29 6.4.2 Set Finger 29 6.4.3 Set PIN Code 29 6.5 Unlock the Door 30 ENTR® Dead Bolt User Manual m I. MUL-T-LDCK' I ENTR‘ I mm; mm 6.6 Lock Door 31 6.7 Low-battery Indication 31 6.8 Setting Menu 31 6.9 Add User ................................................................ 32 6.10 Delete User .............................................................. 33 6.11 Enable/Disable User ................................................................................. 33 6.12 Delete all Users ...................................................................... 34 6.13 Add Time Schedule 34 6.14 Edit Time Schedule 35 6.15 Volume Control 35 6.16 Double Security 36 6.17 Factory Reset 36 7- Smartphone App ............................................................................................................................. 37 7-1 APP Installation . .............................................................. 37 7-2 Pairing Smaitphone ............................................................ 38 8. Remote Control Battery Change 39 8-1 Battery Removal .......................................... .39 8.2 Battery Insertion 9. Troubleshooting 41 10.1 Limitations and External Influences 41 10.2 Cases 41 Limited warranty. ................................................. 44 Federal Communications Commission (FCC) Statement 47 ENTR® Dead Bolt User Manual Y I ENTR‘ I .MUL-T-Locn' mm; “er: 1. Cylinder Installation 1.1 Package Content 1 Base plate & Knob 5 Battery charger 2 Electrical unit 6 Magnet 3 Mounting screw 7 Inside drive adapter 4 Panel screw 8 Mounting screws 9 Decorative spacer 10 Allen key #3 1.2 Tools Requirements 0 Small Phillips screwdriver Note: Do not use power tools or any excessive force to assemble ENTR® parts. ENTR® Dead Bolt User Manual 5 Y I ENTR‘ I .MUL-T-Locx' mm; mm 1.3 Prior to Installation i Warning Do not attempt to operate the unit until assembled into the door - Remove knob screw using 1/16" Allen key and take the knob out. - Use a flat screwdriver to remove the cover. - Remove both Allen screws entirely and remove internal mechanism. Note: While removing the internal mechanism secure the outside cylinder from falling. Consider using masking tape or similar. %%- Knob screw Cover 1.4 Unit Installation - Prior to installation check bolt locking direction. - Verify that the bolt is in open position (bolt inside the door, unlocked). . Rotate adapter tail—piece opposite to the bolt locking direction until stopped (see below drawing #1). 0 Verify that the wide teeth is pointing up. If not rotate the external ring until the wide teeth will point up (see below drawing #2). Wide teeth Bolt locking direction ‘- Drawing #2 Drawing #1 Rotate adapter tail piece opposite to the bolt locking direction 6 ENTR® Dead Bolt User Manual Y I ENTR‘ I EMUL-T-LDCK' mm; mm - Place the Inside drive adapter and tighten the screws. Do not over tighten the screws or use power tools. - Place decorative spacer over the Inside drive adapter. - Assemble base plate (top housing & knob). - Tighten cylinder mounting screw. U 7 Mounting screw Decorative spacer “’3 / \ “/g Base plate Note: In case the "Male rectangle" on the adapter is not aligned with the "Female rectangle" on the Knob, the unit will not engage properly and may cause to malfunction. Female rectangle Male rectangle Female rectangle Pll Adapter Adapter ENTR® Dead Bolt User Manual 7 Y I ENTR‘ I .MUL-T-anx' mm; mm - Carefully connect data cable plug. - Assemble electrical unit panel (battery housing). attache to base plate (1) and push down (2). I Tighten electrical unit panel screw. 9 7 Panel screw Electrical unit Data cable plug 1.5 Magnet Fitting Magnet Fitting: - Mount the magnet on the frame moldings, as close as possible to the lock. I The lower part of the magnet should align with the lower point of the slider (see illustration). Note: The magnet area on frame molding should be clean and free from dust, peeling paint etc. Use alcohol if required. Wait until completely dry prior to sticking. 8 ENTR® Dead Bolt User Manual I, MUL-T-LDCK‘ I ENTR' I mm mm Z. ENTR® Description 2.1 ENTR® Description 2.2 Indications Mute (Green) fl Door not closed (Red) ON/OFF switch Touchpad Indications Knob Manual Mode (Green) OK (Green) @ v Battery status (Green/Red) Error (Red) ENTR® Dead Bolt User Manual I. MUL-T-LDCK' I ENTR‘ I mm; “er: 2.3 0N/OFF Switch I Turning the ENTR® lock ON or OFF. 2.3.1 Switchin the ENTR® ON Before turning ENTR® ON, verify that the door is shut. I Move the switch to the ON position. Make sure that the knob is in the zero position (see illustration). I Function and numeric buttons will all blink once. I Hazard beep sound will be emitted and error indication will blink once. I ENTR® is now in operating mode. Note: I After turning ENTR® ON, avoid touching the front panel until beep sound ends. I After turning ENTR® ON, the door will be shut but not locked. 2.3.2 Switching the ENTR® OFF I Move the switch to OFF position. 2.3.3 Low battery indication Zero position Battery red signal rapidly blinking and 2 long beeps will be sounded during every lock/unlock action, indicating that the battery is low and needs to be charged. 10 ENTR® Dead Bolt User Manual Y I ENTR‘ I .MUL-T-Locx' "a 2.4 Initialization of the Lock Initiate the lock by touching the middle of the touch screen with the palm of your hand or fingers for 3 seconds. - Programing buttons and battery status indication light will illuminate for 15 seconds, waiting for user's action. - After 15 seconds of inactivity, ENTR® will idle. 2.5 Default PIN Code The lock's default factory PIN code is: 1 2 3 4 5 # Please note: - Default PIN code must be changed before starting the configuration process. I The PIN code must consist of 4—10 digits using numbers 1 through Sin any sequence. 0 Only the Code and Mute functions will operate until the default PIN code is changed. I Warning: Don't forget/lose the PIN code once changed, otherwise you will be locked out. Keep your new PIN code in a safe place. ENTR® Dead Bolt User Manual 11 In MUL-T-LDCK' 3. Operation 3.1 Changing PIN Code Do not attempt to operate the unit until assembled I ENTR‘ I mm; mm Touch screen with palm orfingers for 3 seconds to active. Mute Clo Del [OK] indication blinks once, 1 long beep emitted. Illuminated buttons turn off. Mute Cig [L'al I 2 7 4 T T .-.: H ll] ii Numeric buttons illuminated. Reenter [New PIN code] III‘ [It] For example: 12312343: Milie- ;:ng [Iel 1 2 3 4 5 # MIA U l] w 'm) ill» 2 Press [Code] Numeric buttons illuminated. Mute Cfg Del 1 g 7 -I z‘ : C 9 MIA Add a ll] yr Ill’ 5 III‘ 3 Numeric buttons illuminated Enter [New pin code] (4710 digits) i» m For example: 123123“ Lei ‘I 2 3 4 5 # Type [Default PIN code] (1 2 3 4 5) in. [is] MUN lfiig [HI 1 2 3 4 5 le MIA II D III‘ 5 [0K] indication blinksonce. 1 long beep emitted. Illuminated buttons turns off. Ht'lla Cfg [:al PIN codes match PIN Code doesn't match [0K] indicatidn illuminated. 2 short beep emitted. New PIN code is set. Halli-J Cfg HI = i ii -. H I 1] iii [Error] indication illuminated. 2 long Beeps emitted for 1 second. ENTR“ goes to menu mode Start the QrOEESS from stage 1. Eel 12 ENTR® Dead Bolt User Manual Y I ENTR‘ I EMUL-T-LDCK' KEVFREE .mse 3.2 Door Configuration The door configuration process sets your lock and door preferences. This process should be done after successful installation ofthe lock. It will take 15-20 seconds to complete. 1 ill‘ 2 ill‘ 3 Important: Verify that the door is Touch screen with palm or fingers Press [Cfg] shut and no key is Inserted into the for 3 seconds to active cylinder during configuration steps. Mute Clg Del Mute Clo Del 1 2 3 l _, \‘\ 4 7 Code MIA d U [] I l] ’x// 3“, PT 4 in» 5 Numeric buttons Illuminated, Press [1] or [3] to configure ENTR” Type [pm code] n» [u] side (see illustratioril. 1 long beep emitted. Press [1] for ENTRw on left side, Press [3] for ENTR“ on right side. ENTR® on left side of the door ENTR® on right side of the door Press [1] Press [3] ENTR® Dead Bolt User Manual 13 In MUL-T-LDCK' Hold the door shut to avoid opening. The lock Will carry out the configuration process. it take's 15720 seconds to complete. Open the door using the handle, Bring the latch as close as possible to the door molding, Note: Do not shut the door. Door moldings ENT (Ewan .mss 7 Configuration OK [Cig] Indication blinks. [Manual] indication illuminated. Turn the knob manually to unlock [Cfg] indication blinks. position and keep the door closed. Note: if the configuration fails Push on [Cfg] Magnet refer to troubleshooting #1 d ' : ~:«:~ia rile .;..M U [I II] V E6? in 8 Configuration 0K Press [Cfg] 0K] Indication blinks once. The lock Will carry out the Zshort beeps emitted, configuration process. illuminated buttons turn off. iiiiie Cig Lei Mule 4;; 'I e d e mi; . l l [i i l] V/ ”N- tfli 3v? ,cff Troubleshooting #1 Lock configuration failed 1. Remove the mechanical key from the lock. 2. Check that the door was closed properly or if lock operation was interfered. 14 ENTR® Dead Bolt User Manual Yum... El m ms. us rm Configuration failed Troubleshooting #2 [Error] indication illuminated. Magnet configuration fai|ed 2 long beeps emitted. , D4 4 . Reiertotroubleshootin #2 1. You can still operate ENTR In Manual mode (w/o automatic locking). 2. Remove any other magnets from the door. Hulls 1.2m pal 3. Place the magnet according to instructions. 4. Consult your installer or contact ENTRD Technical Support. 1 2 3 d 5 : 34M [1]] Vi Magnet Fitting: - Mount the magnet on the frame moldings, as close as possible to the lock. - The lower part of the magnet should align with the lower point of the slider (see illustration). Frame moldings Slider Magnet ENTR® Dead Bolt User Manual 15 In MUL-T-LDCK' I ENTR‘ I mm; mm 3.3 Pairing Remote Control Touch screen with palm Drfingers for 3 seconds to acnve. Mule Clg Dal Press [1] to add remote control. Illuminated buttons turn off. [ox] indication blinks for 15 Seconds, wamng for remote control unit Huh 1:!) [4| 1 2 5 :19 ll // (an Kr HI‘ 2 Press [Add] m‘ 5 Press the remote control button, III» 3 Numenc buttons illuminated. Type [PIN code] \II‘ [a] Numeric buttons blinking. mm :12; 1 2 3 4 5 # Remote control button 16 ENTR® Dead Bolt User Manual In MUL-T-LDCK' I ENTR‘ I mm; Inns: Pairing 0K Pairing failed [0K] indication blinks once, 2 short beeps emitted. Remote control unit addedt llIIll—. Cfg [ =| Notes: [0K] indication blinks for 15 seconds, No beeps emitted. Start the process from stage 1. - To add more remote control units repeat this procedure. - A remote control unit can be paired with only one single door unit. - It is possible to add up to 20 remote control units. 0 Only authorized dealer can reset a paired remote. 3.4 Deleting Remote Control The deleting remote control process‘ will delete a_H remote control units including Touchpad and Fingerprint readers defined within the system. ul’ 3 Touch screen WIth palm orfingers for 3 seconds to active. Mute Ciq Del ul’ 2 Press [Del] Numeric buttons illuminated. Mute qu Del 4 ' # Code MIA Add II U [l] \V/ in. yr \W \\ Type [PIN code] ul’ [#1 1 long beep emitted. Hull» in [Vi 1 2 3 4 5 # _ .’ is (‘l 'i V” ENTR® Dead Bolt User Manual 17 Y I ENTR‘ I .MUL-T-ann' mm; unis: 4 ”l» 5 Deletion accomplished [Del] blinks for 30 seconds. Press [Del] to confirm. 0K] indication blinks once 2 5mm beeps emitted, iiluminated buttons turn off. iii-Ii» .11 ' liliila _ .1 J Del Nut—- Clg Lei l L z | L 3 | L T, 4 ‘ :: .1 :' _z't W .1 :- : .r 1+ IiI,—, ,..-»ii . J~ ii|... Add r. _, . ,. H D II] !' [1 Hi \ \w H. yr y ii; yr Note: Wall reader and smartphone connected to the ENTR® lock will not be deleted. 3.5 Setting Sound Signal Turn the sound signal to OFF or ON 1 ill‘ 2 ill» 3 Touch screen With pairri orfirigers for Press [Mute] [Mute] indication iiluminated. 3 seconds m active. Sound signal is off. Mule Cfg Del Mule Cfg Del Mule Gig Del 1 2 3 | ’ 3 l L 7 4 4 : :3 Code Code MIA Add II n I 1] H l] y Ivi VT \‘// in Notes: - Setting the ENTR® lock sound to OFF will mute the lock and unlock sounds, and the open door hazard signal. It will not mute the touchpad, mechanical override and low-battery sounds. I Follow the same procedure to turn the sound back to ON. 18 ENTR® Dead Bolt User Manual In MUL-T-LDCK' 3.6 Setting Locking Mode Toggle between Automatic to Manual locking mode ul‘ 2 III» 3 Touch screen with palm orfingers for 3 Seconds to actlve. Press [MIA] Mute Cfg Del [Manual] indication illuminated. Mute Clg Del Code MIA Add Ill [] ll] Notes: Tvpe [PIN code] ul‘ [5?] I Setting the ENTR® lock to Manual will disable automatic locking. 0 Follow the same procedure to set the ENTR® lock to Automatic locking. l ii’l {nil i-«iu Ii. [HI I ENTR‘ I mm; Inns: ENTR® Dead Bolt User Manual 19 Y I ENTR‘ I .MUL-T-ann' mm; mm 3.7 Doorknob Operation Turn clockwise or counterclockwise to unlock. Beep sound emitted during doorknob operation. Important! When an active lock is opened by turning of the knob you must re—operate it by one of its automatic modes (i.e remote, phone, sliding your fingers, touch pad etc.) or else it will remain UNLOCKED. Knob operation is meant solely for mechanical override in the rare event it will not otherwise unlock. 3.8 Slide Buttons Operation Slide your fingers on the recessed grooves on both sides of the ENTR® front panel: - To open, slide fingers downwards on the recessed grooves on both sides. / 0 To lock, slide fingers upwards on the recessed grooves on both sides. we 2i 2° ENTR® Dead Bolt User Manual Y I ENTR‘ I .MUL-T-ann' m. 4. Touchpad Reader 4.1 Mounting the Touchpad Reader Select the location where the Touchpad Reader will be mounted. 0 Attach the Touchpad Reader baseplate to the wall. - Use 4 screws and screw anchors, or double sided adhesive strip. 4.2 Battery Replacement 1. Release lid screw and open the lid. 2. Put in the batteries (ZXAA) according to the "+" "—" signs. 3. Close the lid and tighten the screw. Notes: - After inserting the batteries the Touchpad Reader will turn on automatically. 0 A short beep sound emitted and Green [OK] indication illuminated for 2 seconds. Important: Do not touch the Touchpad during the self test procedure and until the lights a re off. 4.2.1 Low Batten; Indication When batteries need replacement, a red warning signal will blink rapidly and long beep will sound during every lock/unlock action. ENTR® Dead Bolt User Manual 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2016:12:28 13:42:31+08:00 Create Date : 2016:12:28 10:52:51+08:00 Metadata Date : 2016:12:28 13:42:31+08:00 Creator Tool : PDFCreator Version 1.2.3 Format : application/pdf Title : ENTRR Fingerprint Reader_user manual_FCC,IC.pdf Creator : suhsiao Document ID : uuid:cb7c53cc-c301-43f8-8194-d4f1fac66892 Instance ID : uuid:a1fa15ea-f37b-410f-b9f9-da6d6002dfd7 Producer : PDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)] Page Count : 20 Author : suhsiaoEXIF Metadata provided by EXIF.tools