MUL T LOCK TECHNOLOGIES ENTRWRT00 ENTR Touchpad Reader User Manual ENTRR Fingerprint Reader FCC IC

MUL-T-LOCK TECHNOLOGIES LTD ENTR Touchpad Reader ENTRR Fingerprint Reader FCC IC

Users Manual Part 1.pdf

Download: MUL T LOCK TECHNOLOGIES ENTRWRT00 ENTR Touchpad Reader User Manual ENTRR Fingerprint Reader  FCC IC
Mirror Download [FCC.gov]MUL T LOCK TECHNOLOGIES ENTRWRT00 ENTR Touchpad Reader User Manual ENTRR Fingerprint Reader  FCC IC
Document ID3248288
Application IDX4QTZrUxFDNCev6T9HuyxA==
Document DescriptionUsers Manual Part 1.pdf
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize327.37kB (4092150 bits)
Date Submitted2017-01-05 00:00:00
Date Available2017-07-04 00:00:00
Creation Date2016-12-27 17:50:31
Producing SoftwarePDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)]
Document Lastmod2016-12-27 17:50:40
Document TitleENTRR Fingerprint Reader_user manual_FCC,IC.pdf
Document CreatorPDFCreator Version 1.2.3
Document Author: suhsiao

In Mlll.-'I'-LIII:I(z
I ENTR‘ I
m mm m:
Table of Content
1- Cylinder Installation .............................................................. 5
11 Package Content ......................................................................... 5
12 Tools Requirements ................................................................. 5
1.3 Prior to Installation ......................................................................... 5
1.4 Cylinder & Unit Installation ................................................................. 6
1.5 Magnet Fitting ..... 8
2. ENTR® Description 9
2.1 ENTRE Description .............................................................. 9
2.2 Indications ..................................................................................................................................... 9
2-3 0N/0FF Switch ................................................................................................................................ 10
2.3.1 Switching the ENTRQ 0N ............................................................. 10
23-2 Switching the ENTR‘“ OFF .......................................... 10
2.33 Low Battery Indication ............................................................. 10
2.4 Initiating the Lock ................................................................. 11
2.5 Default PIN Code 11
3- Operation ....................................................................... 12
3.1 Changing PIN Code ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 12
3.2 Door Configuration .............................................................. 13
3.3 Pairing Remote Control 16
3.4 Deleting Remote Control .............................................................. 17
3.5 Setting the Sound Signal ...................................................... 18
3.6 Setting Locking Mode .............................................................. 19
3-7 Operated by Knob ................................................................... 20
3.8 Operated by Slide Buttons 20
ii
ENTR® Dead Bolt User Manual
T I ENTR‘ I
.MUL-‘r-Locx‘
m mm m:
4- Touchpad Reader ........................................................................ .21
4.1 Changing PIN Code ..................................................... 21
4.2 Battery Replacement ............................................................ 21
42.1 Low Battery Indication ..................................................... 21
5. Touchpad Reader Operation 22
5.1 Operation VVVVVVVVVVVV 22
5.2 Pairing Touchpad Reader .............................................................. 22
5-3 Touchpad Reader Master PIN Code ........................................... 24
5.4 Menu Mode ..................................................... 24
5.5 Adding Personal User Code ............................................... 24
5.6 Open Door ................................................................... 25
5.7 Lock Door. ............................................................... 25
5.8 Delete Personal User Code ................................................. 25
5.9 Delete All Personal User Codes ....................................... 25
5.10 Volume Control 26
5.11 Factory Reset 26
6- Fingerprint Reader ..................................................... .27
6-1 Mounting the Fingerprint Reader .................................... 27
62 Battery Replacement ............................................................ 27
6.3 Adjust Date & Time ..... 27
6.4 Pairing Fingerprint Reader ............................................................. 28
6.4.1 Add Master ....................................................................... 29
6.4.2 Set Finger 29
6.4.3 Set PIN Code 29
6.5 Unlock the Door 30
ENTR® Dead Bolt User Manual m
I. Mlll.-'I'-LIII:I(z
I ENTR‘ I
m mm m:
6-6 Lock Door. ............................................................... 31
6-7 Low—battery Indication ................................................................. 31
6.8 Setting Menu
69 Add User ...................................................................... 32
6.10 Delete User ............................................................. 33
6.11 Enable/Disable User .............................................................................. 33
6.12 Delete all Users ........................................................................ 34
6.13 Add Time Schedule 34
6.14 Edit Time Schedule 35
6.15 Volume Control 35
6.16 Double Security 36
6.17 Factory Reset 36
7- Smartphone App ............................................................................................................................. 37
7-1 App Installation ............................................................. 37
7-2 Pairing Smartphone .......................................................... 38
8. Remote Control Battery Change 39
81 Battery Removal ........................................... .39
8.2 Battery Insertion
9. Troubleshooting 41
10.1 Limitations and External Influences 41
10.2 Cases 41
Limited warranty ........................................... ,....44
Federal Communications Commission (FCC) Statement 47
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
Emma-Loon:
m mm m:
1. Cylinder Installation
1.1 Package Content
1 Base plate & Knob 5 Battery charger
2 Electrical unit 6 Magnet
3 Mounting screw 7 Inside drive adapter
4 Panel screw 8 Mounting screws
9 Decorative spacer 10 Allen key #3
1.2 Tools Requirements
0 Small Phillips screwdriver
Note: Do not use power tools or any excessive force to assemble ENTR® parts.
ENTR® Dead Bolt User Manual 5
Y I ENTR‘ I
liIL-T-LOCK‘
m mg.“ m:
1.3 Prior to Installation
i Warning: Do not attempt to operate the unit until assembled into the door
0 Remove knob screw using 1/16" Allen key and take the knob out.
- Use a flat screwdriver to remove the cover.
I Remove both Allen screws entirely and remove internal mechanism.
Note: While removing the internal mechanism secure the outside cylinder from
falling. Consider using masking tape or similar.
%%W
Knob screw
Cover
1.4 Unit Installation
- Prior to installation check bolt locking direction.
. Verify that the bolt is in open position (bolt inside the door, unlocked).
. Rotate adapter tail—piece opposite to the bolt locking direction until stopped (see
below drawing #1).
0 Verify that the wide teeth is pointing up. If not rotate the external ring until the
wide teeth will point up (see below drawing #2).
Wide teeth
Bolt locking direction
‘-
Drawing #2
Drawing #1
Rotate adapter tail piece opposite
to the bolt locking direcfion
6 ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MUL-‘r-Locx‘
m mm m:
- Place the Inside drive adapter and tighten the
screws. Do not over tighten the screws or use
power tools.
Adapter
- Place decorative spacer over the
Inside drive adapter.
- Assemble base plate (top
housing & knob).
o Tighten cylinder mounting screw.
U7 Mounting screw
Decorative spacer
% ‘ Base plate
Note: In case the "Male rectangle" on the adapter is not aligned with the "Female
rectangle" on the Knob, the unit will not engage properly and may cause to malfunction.
Female rectangle Male rectangle Female rectangle
Mil
Adapter Adapter
ENTR® Dead Bolt User Manual 7
Im MUL—T—LOCK‘
- Carefully connect data cable plug.
I ENTR‘ I
m mg.“ m:
. Assemble electrical unit panel (battery housing). attache to base
plate (1) and push down (2).
- Tighten electrical unit panel screw.
Electrical unit
Data cable plug
a Q/@
1.5 Magnet Fitting
Magnet Fitting:
- Mount the magnet on the frame
moldings, as close as possible to
the lock.
I The lower part of the magnet should
align with the lower point of the slider
(see illustration).
Note: The magnet area on frame molding
should be clean and free from dust,
peeling paint etc. Use alcohol if required.
Wait until completely dry prior to sticking.
B 7 Panel screw
6) Q/@
Frame
molding
Magnet
ENTR® Dead Bolt User Manual
I, Mul—T—LDCK‘
I ENTR’ I
m mm m;
2. ENTR® Description
2.1 ENTR® Description
2.2 Indications
Mute (Green)
fl
Door not closed (Red)
ON/OFF switch
Touchpad
Indications
Knob
Mm. CW Do!
1 2 3
A 5 it
Cod' nu Add
Manual Mode (Green) 0K (Green)
@ W
Battery status (Green/Red) Error (Red)
ENTR® Dead Bolt User Manual
In Mlll.-'I'-LIII:I(z
2.3 ON/OFF Switch
I Turning the ENTR® lock ON or OFF.
2.3.1 Switchin the ENTR® ON
Before turning ENTR® 0N, verify that the
door is shut.
I Move the switch to the ON position.
Make sure that the knob is in the zero
position (see illustration).
I Function and numeric buttons will all
blink once.
I Hazard beep sound will be emitted and
error indication will blink once.
I ENTR® is now in operating mode.
Note:
I After turning ENTR® ON, avoid touching
the front panel until beep sound ends.
I After turning ENTR® ON, the door will be
shut but not locked.
2.3.2 Switching the ENTR® OFF
I Move the switch to OFF position.
2.3.3 Low battery indication
I ENTR‘ I
m mm m:
Zero position
Battery red signal rapidly blinking and 2 long beeps will be sounded during every
lock/unlock action, indicating that the battery is low and needs to be charged.
10
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MUL-‘r-Locx‘
m mg.“ m:
2.4 Initialization of the Lock
Initiate the lock by touching the middle ofthe touch screen
with the palm of your hand or fingers for 3 seconds.
Mule Cfg Del
I Programing buttons and battery status indication light
will illuminate for 15 seconds, waiting for user's action.
I After 15 seconds of inactivity, ENTR® will idle.
2.5 Default PIN Code
The Iock's default factory PIN code is: 1 2 3 4 5 #
Please note:
. Default PIN code must be changed before starting the configuration process.
I The PIN code must consist of 4-10 digits using numbers 1 through Sin any sequence.
I Only the Code and Mute functions will operate until the default PIN code is changed.
I Warning: Don't forget/lose the PIN code once changed, otherwise you will be
locked out. Keep your new PIN code in a safe place.
ENTR® Dead Bolt User Manual 11
Y I ENTR‘ I
liIL-T-LDCK‘
m FEEL-E mt
3. Operation
3.1 Changing PIN Code
Warning: Do not attempt to operate the unit until ass bled on the door.
1 III‘ 2 ill‘ 3
Touch screen with palm or fingers for Press [Code] Type [Default PIN code]
3 seconds to active. Numeric buttons illuminated. 11 2 3 4 5) in. [:1]
Nuts Clo Del Mute 09 Del
1 2 3
c 0 MIA Add
a H]
if
4 III’ 5 ill» 6
[OK] indication blinks once, Numeric buttons illuminated Enter [OK] indication blinks once.
1 long beep emitted. [New PIN code] (4710 digits) HQ [3:] 1long beep emitted.
Illuminated buttons turn off. For example: 123123“ Illuminated buttons turns off.
Hut: crg [iel Mute r el Mn. is Cig rzel
1 :_~ 7, 1 2 3 ‘l : 7,
4 ’ 4 5 # d 3 :::
u: 14 HI: end-4 Ia. MIA “
I I |I] ll U
' @ fii’ // at»
7 PIN codes match PIN Code doesn't match
Numeric buttons illuminated. [OK] indication illuminated. [Error] indication illuminated.
Reenter [New PIN code] lll‘ [d 2 short beep emitted. 2 long Beeps emitted for 1 second.
For example: 1231234# New PIN code is set. ENTRa goes to menu mode.
Start the grocess from stage 1.
Nuts I I‘lllii-i Cig [, al Mute: L12} Eel
’I 2 3 l '4 V 1 2 3
4 5 # A ‘ : 4 5 #
I‘ll; ll 32:1:1
_I ll] ll]
M’ @ i3“ fii’
12 ENTR® Dead Bolt User Manual
Y I ENTR‘ I
anlL-T-LOCK’
m mm m:
3.2 Door Configuration
The door configuration process sets your lock and door preferences.
This process should be done after successful installation of the lock. It will take 15-20
seconds to complete.
1 ill» 2 ill» 3
Important: Verify that the door is Touch screen with palm or fingers Press [Cfg]
shut and no key is inserted Into the for 3 seconds to active.
cylinder during configuration steps.
Mute Cig Del Mute Clq Del
Code MIA d
\i
4 HQ 5
Numeric buttons illuminated, Press [1] or [3] to configure ENTR"
Type [pm code] iuQ [a] side (see illustrationl.
1 long beep emitted. Press [1] for ENTRw on left side,
Press [3] for ENTR" on right side,
ENTR” on left
side of the door
ENTR‘R‘ on right
side of the door
Press [1] Press [3]
ENTR® Dead Bolt User Manual 13
Ia Mlll-T-LDCK‘
ENT
m meat m:
Hold the door shut to avoid opening.
The iock will carry out the
configuration process.
It take's 15720 seconds to compiete.
[Cig] Indication blinks.
Turn the knob manuailyto unlock
position and keep the door dosed.
Push on [Cfg]
Configuration OK
[Manual] indication iiluminated.
[Clg] indication blinks.
Note: irthe configuration raiis
refer to troubieshooting #1
Open the door using the handle.
Bring the latch as dose as possible to
the door molding,
Note: Do not shut the door.
Door
moldings
Magnet
MIN:
8 Configuration 0K
Press [Cfg]
The iock will carry out the
configuration process.
[0K] Indlcation blinks once.
2 short beeps emitted,
Iliuminated buttons turn off.
Muir,
Troubleshooting #1
Lock configuration failed
1. Remove the mechanical key from the lock.
2. Check that the door was closed properly or if
lock operation was interfered.
14
ENTR® Dead Bolt User Manual
Y I ENTR‘ I
., m-T-LOCK'
m mt. .s mi
Configuration failed Troubleshooting #2
[Error] indication illuminated, Magnet configuration failed
2 long beeps emitted.
Refer to troubleshootin #2 it You can still operate ENTR" in Manual mode (w/o automatic locking).
Remove any other magnets from the door.
Place the magnet according to instructions,
Consult your installer or contact ENTR" Technical Support.
Huh: Ck} Del
PE”!"
13
Magnet Fitting:
. Mount the magnet on the frame moldings, as close as possible to the lock.
0 The lower part of the magnet should align with the lower point of the
slider (see illustration).
Frame
moldings
Magnet
ENTR® Dead Bolt User Manual 15
Y I ENTR‘ I
“moor-Loon!
m mm m:
3.3 Pairing Remote Control
1 HI‘ 2 III» 3
Touch screen with palm or fingers for Press [Add] Numerlc buttons illuminated.
3 seconds to actwe. Type PIN code] ul’ [#1
Numeric buttons blinking.
Mule Clg Del
Clg Mn-i: llial
4 In» 5
Press [1] to add remote control. Press the remote control button,
Illuminated buttons turn off.
[OK] indlcafion blinks for 15 Seconds,
waiting for remote control unit
mu :1; I-el
Remote control
1 2 3 button
4:19
:1
4 In“ 71
16 ENTR® Dead Bolt User Manual
In Mlll.-'I'-LIII:I(z
I ENTR‘ I
m mm m:
Pairing OK
Pairing failed
[OK] indication biinks once,
2 short beeps emitted.
Remote control unit added.
C19 1-“
Notes:
No beeps emitted.
DK] indication bilnks for 15 seconds,
Start the process from stage 1.
- To add more remote control units repeat this procedure.
- A remote control unit can be paired with only one single door unit.
- It is possible to add up to 20 remote control units.
0 Only authorized dealer can reset a paired remote.
3.4 Deleting Remote Control
The deleting remote control process‘ will delete a_H remote control units including
Touchpad and Fingerprint readers defined within the system.
ill» 3
Touch screen with palm orfingers for
3 seconds to active.
Mute Cig Del
ill’ 2
Press [Del]
Numeric buttons iiluminated.
Mute Cfg Del
— 7 #
Coda MIA Add
U G]
{V UL J/
\W
Type [PIN code] ul’ [it]
1 long beep emitted.
1 2
4 5
. de
ENTR® Dead Bolt User Manual
17
Y I ENTR‘ I
.MUL-‘r-Locx‘
m mm m:
4 '1'» 5 Deletion accomplished
[Del blinks for 30 seconds. Press [Del] to confirm. [0K] indication blinks once
2 short beeps emitted,
illuminated buttons turn off.
I I
_ l . : Del : l Del , Cfg [,4
l » ‘ , 3 W , /
s , s s , 4-: s , :
.r: , l . 1‘ ..,,l l . \dd \ '. , i . .
J y“ x/ . y“ i 4 5 ® v“
Note: Wall reader and smartphone connected to the ENTR® lock will not be deleted.
3.5 Setting Sound Signal
Turn the sound signal to OFF or ON
1 ill‘ 2 in» 3
Touch screen with palm orfirigers for Press [Mute] [Mute] Indication illuminated.
3 seconds to active. Sound signal is off.
Mule Cfg Del Mute C19 Del Mule Gig Del
1 2 3 l 3
J s -'~
Code Code MIA Add
V i y“ M/
Notes:
- Setting the ENTR® lock sound to OFF will mute the lock and unlock sounds, and
the open door hazard signal. It will not mute the touchpad, mechanical override
and low-battery sounds.
. Follow the same procedure to turn the sound back to ON.
18 ENTR® Dead Bolt User Manual
In Mlll-T-LDCK’
3.6 Setting Locking Mode
Toggle between Automatic to Manual locking mode
ill. 2
Touch screen with palm orfingers for Press [MIA]
3 seconds to active,
Mute Cfg Del Mule C19 Del
[Manual] indication illuminated.
Mule Cfg Del
Notes:
III» 3
Type [pin code] ill. [#1
- Setting the ENTR® lock to Manual will disable automatic locking.
- Follow the same procedure to set the ENTR® lock to Automatic locking.
I ENTR‘ I
m mu; m:
ENTR® Dead Bolt User Manual
19
Y I ENTR‘ I
.MUL-‘r-Locx‘
m mu; m:
3.7 Doorknob Operation
Turn clockwise or counterclockwise to unlock.
Beep sound emitted during doorknob operation.
Important! When an active lock is opened by
turning of the knob you must re—operate it by
one of its automatic modes (i.e remote, phone,
sliding your fingers, touch pad etc.) or else it will
remain UNLOCKED.
Knob operation is meant solely for mechanical
override in the rare event it will not otherwise
unlock.
3.8 Slide Buttons Operation
Slide your fingers on the recessed grooves on both
sides of the ENTR® front panel:
0 To open, slide fingers downwards on the recessed
grooves on both sides. /
- To lock, slide fingers upwards on the recessed
grooves on both sides.
\r/{o
2i
20 ENTR® Dead Bolt User Manual
Y I ENTR‘ I
.MllL-T-LDCK‘
m mu; m:
4. Touchpad Reader
4.1 Mounting the Touchpad Reader
Select the location where the Touchpad Reader will be
mounted.
- Attach the Touchpad Reader baseplate to the wall.
- Use 4 screws and screw anchors, or double sided
adhesive strip.
4.2 Battery Replacement
1. Release lid screw and open the lid.
2. Put in the batteries (ZXAA) according
to the "+" "—" signs.
3. Close the lid and tighten the screw.
Notes:
- After inserting the batteries the Touchpad
Reader will turn on automatically.
0 A short beep sound emitted and Green
[OK] indication illuminated for 2 seconds.
Important: Do not touch the Touchpad during
the self test procedure and until the lights
are off.
4.2.1 Low Battery Indication
When batteries need replacement, a red
warning signal will blink rapidly and long beep
will sound during every lock/unlock action.
ENTR® Dead Bolt User Manual 21

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2016:12:27 17:50:40+08:00
Create Date                     : 2016:12:27 17:50:31+08:00
Metadata Date                   : 2016:12:27 17:50:40+08:00
Creator Tool                    : PDFCreator Version 1.2.3
Format                          : application/pdf
Title                           : ENTRR Fingerprint Reader_user manual_FCC,IC.pdf
Creator                         : suhsiao
Document ID                     : uuid:b53a14b4-d084-4a98-9cdc-eae93959fa0b
Instance ID                     : uuid:21ddd559-42f5-4369-bb2b-7b8a016b14eb
Producer                        : PDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)]
Page Count                      : 20
Author                          : suhsiao
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AHH8ENTRWRT00

Navigation menu