OPTIONS FOR MOUNTING & FRONT COVER FACEPLATE
Cover of MD2-ZB can easily be removed by
pulling off cover at the two side indents (1).

INSTALLATION INSTRUCTIONS MD2-ZB
POWER STATUS INDICATOR LIGHTS

Cover can be flipped around 180 degrees to
hide LEDs from front straight-on view if desired.

2

PUSH BUTTONS
For Outlet’s Power ON/OFF
and Network Connection

Outlet 1
Network
Connection
Status

INDICATOR
LIGHTS
Outlet 2

1

Wiring Fault
OUTLET 1
Left side
Ground Pin Out

OUTLET 2
Right side.
Ground Pin
Down

Cover can be removed & painted to match color
of wall. The cover only can be painted. Do not
paint the sides, top or bottom of the unit or
Warranty will be voided.

Unit can be securely screwed into wall outlet
faceplate using either hole (2) indicated (screw
is included).

SPECIFICATIONS
Electrical Ratings
Line Voltage ______ 120 Vac, 60Hz
Current Rating _____ 12 A
Voltage Protection Rating (UL 1449 3rd Edition,
3,000A) _________ 400V L-N, 600V L-G, 		
		500V N-G
Nominal Discharge Current
(UL1449 3rd Edition _ 3,000A
Electrical Measurements
RMS Voltage ______ 1% precision
RMS Current ______ 1% precision
Power___________ 2% precision
Cumulative Energy__ 2% precision

General
Weight__________ 0.7lb
Dimensions_______ 3.25 in. W X 1.625 in.
		
D X 5.25 in. H

ZigBee is a registered trademark of ZigBee Alliance, Inc.

AGENCY APPROVALS

WARRANTY POLICIES

CCSAUS

Certified: UL1449 3rd Edition
(Type 3 SPD), CSA C22.2 No. 42
UL 1449 Voltage Protection Rating:
400V L-N, 600V L-G, 500V N-G

Product Warranty: Limited 3 Year Warranty
Connected Equipment Protection Policy:
Limited $100,000
Connected Equipment Policy

C

www.panamax.com

RF / ZigBee®
ZigBee®/802.15.4 Radio
2.405-2.475 GHz, unlicensed ISM band
3dBm transmitter output
-99dBm receiver sensitivity

REMOVABLE COVER
FACEPLATE
Finger Indent to
Pull Off Cover.

This device complies with part 15
of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.

MD2-ZB

This equipment has been tested and found to comply with the limits for a Class B digital device in
accordance with the specifications of Part 15 of FCC rules. These specifications are designed to
provide reasonable protection against such interference win a residential installation.
However, there is no guarantee that interference will not occur in a particular installation.
In accordance with FCC 15.21, changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.

US

www.mybluebolt.com

www.panamax.com

www.mybluebolt.com
DIN-00019-B

11/12

2.

Plug MD2-ZB into the wall outlet. The
red WIRING FAULT light indicates an improperly wired outlet that must be checked
by a qualified electrician.

4.

Press the OUTLET 1 and/or OUTLET 2
buttons to switch power on the respective
outlets.

WIRING FAULT

OUTLET 2

BlueB LT

®

OUTLET 2

5. If the NETWORK / DEMAND
RESPONSE light is RED, the MD2-ZB
is not connected to a ZigBee network.
Proceed to step 6, SETUP.

SETUP
6.

Verify that a BlueBOLT® device (BB-ZB1
or another MD2-ZB) is powered on and within
100 ft. of that active BlueBOLT® device.

MD2-ZB requires BB-ZB1 Gateway (sold separately).

BlueB LT
BlueB LT

Through the BlueBOLT® interface,
enable JOINING. Refer to the user manual
for BB-ZB1 for detailed instructions.
NETWORK CONNECT
PUSH BOTH
SIMULTANEOUSLY

OUTLET 1

WIRING FAULT

OUTLET 1

7.

OUTLET 2

8. On MD2-ZB, press and hold the
OUTLET 1 and OUTLET 2 buttons simultaneously until the NETWORK / DEMAND
RESPONSE light blips / blinks / flashes,
approximately 4 seconds. The NETWORK/
DEMAND / RESPONSE light will turn
GREEN once it has joined the network.

®

®

100 ft. Maximum

100 ft. Maximum

100 ft. Max.

BB-ZB1
MD2-ZB

MD2-ZB

BlueB LT

®

MD2-ZB

Multiple MD2-ZB units can be installed within 100 ft. from an active device (BB-ZB1 or another active MD2-ZB).

www.panamax.com

OUTLET 2

OUTLET 2

OUTLET 2

NETWORK CONNECT
PUSH BOTH
SIMULTANEOUSLY

NETWORK
DEMAND RESP.

OUTLET 1
OUTLET 1

OUTLET 1

NETWORK CONNECT
PUSH BOTH
SIMULTANEOUSLY

®

OUTLET 1

®

WIRING FAULT

BlueB LT

OUTLET 2

BlueB LT

Plug your equipment into the AC outlets.

OUTLET 1

WIRING FAULT

NETWORK CONNECT
PUSH BOTH
SIMULTANEOUSLY

OUTLET 2

NETWORK
DEMAND RESP.

OUTLET 1

Turn OFF the equipment that you are
plugging into the MD2-ZB

NETWORK
DEMAND RESP.

3.

1.

NETWORK
DEMAND RESP.

INSTALLATION

www.mybluebolt.com

