Merrytek Technology MC603S Microwave Motion Sensor User Manual 2AI53 MC603S MC603S Manual
Shenzhen Merrytek Technology CO., LTD Microwave Motion Sensor 2AI53 MC603S MC603S Manual
2AI53-MC603S_MC603S Manual
MC603S FCC Warnning: MICROWAVE MOTION SENSOR USER’S MANUAL Model No.: MC603S This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. US GENERALGUIDELINESFORINSTALLATION FEATURES Automatic switching based on motion and light level. 1, The sensor should be installed by a qualified electrician. And ensure Zero-crossing point operation helps protect the sensor against that the electricity supply is switched off before installing or servicing in-rush current. the product. Super Compact size makes it suitable to fix within most luminaires. 2, The sensor should not be modified in any way. Any modifications 4-pole press-in terminal (L, N, N, L'), easy assembly. made for this product will immediately invalidate any warranties issued. Detection area, time delay and daylight threshold can be precisely set via DIP switch. 3, The company does not accept responsibility for any consequences resulting from unauthorized modification of the product. 4, The sensor should be connected to a stable power supply of 220240Vac 50Hz/60Hz. 5, Microwaves cannot pass through metal or brick walls if thicker than 20cm. They will pass through thinner walls but there will be some attenuation. Operating voltage 120/277Vac, 50/60Hz Rated load 200W@120Vac 400W@277Vac-Ballast 6, Installation inside a glass or plastic housing will result in a reduction of 400W@120Vac 800W@ 277Vac-Resistive detection sensitivity. Expect a reduction of approximately 20% for every HF system 5.8GHz±75MHz, ISM wave band Transmitting power <0.5mW Power consumption ≤0.5W(standby) Detection zone Max.(D x H): 10m x 6m Detection sensitivity 10% / 50% / 75% / 100% Hold time 5s / 30s / 90s / 3min / 20min / 30min Daylight sensor 2lux / 10lux / 25lux / 50lux / Disable Mounting height 6m Max. 3mm of thickness. INSTALLATION & WIRING The sensor has 7-position terminal block as Pic 1: L(Phase) N(Neutral) L (Switched phase / control) Motion detection 0.5~3m/s 1-10V (Connected to 1-10V interface) Sync Detection angle 150°(wall installation) (synchronization) 360°(ceiling installation) Operating temperature -25℃~60℃ IP rating IP20 Pic 1 The sensor is designed for installation at 2.5-12m in height. SETTINGS WIRING SCHEME Detection area, hold time and daylight sensor can be set by using DIP switches on the sensor. Note that reducing the detection area will also reduce the sensitivity. FOR ON/OFF FUNCTION : Connect to normal control gears (normal LED drivers or ballasts), the wiring as following: 1, Detection area I: up to 100% II: up to 75% III: up to 50% IV: up to 10% Control gear Control gear Control gear Max. 400W L N 2, Hold time Refers to the time period the lamp remains at 100% illumination after no motion is detected. I: 5s II: 30s III: 90s IV: 3min V: 20min VI:30min 1 2 ON Ⅰ Ⅱ Ⅲ Ⅳ ON ON 100% ON 75% 50% ON 10% 3 4 5 ON Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ Ⅳ ON ON ON 5s ON ON 30s ON ON 90s ON 3min ON ON 20min 30min When set to 30min,The sensor function will be inactive, the light will go back to normal one. 3,Daylight sensor The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold. The settings are as follows: DETECTION PATTERN 14 12 10 ON 100% 75% 100% 75% 50% 50% 10% 10% 10 12 14 I: 2lux, darkness operation only II: 10lux, darkness operation only III: 25lux, twilight operation IV: 50lux, twilight operation V: Disable 6 7 8 Ⅰ ON ON ON 2lux 10lux Ⅱ ON ON ON Ⅲ 25lux 50lux Ⅳ ON Disable Ⅴ 10 12 14 Wall mounting pattern (Unit: m) Suggested installation height: 1-1.8m Ceiling mounting pattern (Unit: m) Suggested installation height: 2.5-6m *When set to Disable, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light levels. *It should be set to Disable mode if the motion sensor is connected to stand-alone daylight sensors. 4,Stand-by dimming level When set to “Const-ant ON”, the microwave sensor function is inactive, lights turns on or off by switch. When set to Sensor, the microwave sensor function is active. ON Constant ON FAQ Question The load will not illuminate Incorrect daylight sensor setting selected. Adjust setting. Load has failed. Replace load. Power is switched off. Switch on. Continuous movement in the detection area. Check detection area setting. The load is permanently The lamp (containing sensor) is illuminated. installed in an area too close to reflective surfaces, i.e. metal, glass or concrete walls. The load will not illuminate despite movement. Remedy Cause Speed of moving object is not in the range of 0.5-3m/s or the detection radius is too small. 1, Make sure installation area suitable with at least 30cm space between lamp and surrounding reflective surfaces. 2, Reduce sensitivity (detection area). Check detection area setting. Shenzhen Merrytek Technology Co..Ltd No.3 Building, 380 Xiangshan Avenue, No.3 Industrial Park Luotian, Songgang Town, Bao’an District, Shenzhen 518105, Guangdong, China www.merrytek.com Email:sales@merrytek.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Profile CMM Type : Linotronic Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : Hewlett-Packard Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : Hewlett-Packard Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 2 Create Date : 2018:03:27 14:51:17+08:00 Modify Date : 2018:03:27 14:51:17+08:00 Producer : Corel PDF Engine Version 17.4.0.887 Author : Administrator Creator : CorelDRAW X7 Title : MC603S 说明书---开发用.cdrEXIF Metadata provided by EXIF.tools