Meru Networks OAP180R2 Outdoor Access Point, Model OAP-180 User Manual AP Install
Meru Networks Inc. Outdoor Access Point, Model OAP-180 AP Install
User Manual
Internal Use Only—Beta Draft Meru Access Point and Radio Switch Installation Guide Copyright © Meru Networks, Inc., 2003–2008. All rights reserved. Other names and brands may be claimed as the property of others. Document Number: 3.6_ap_install_revA2 Internal Use Only—Beta Draft Internal Use Only—Beta Draft Contents About This Guide . . . . . . . . . . . . . . . . . . . . . . .xi Audience . . . . . . . . . . . . . . . . . . . . . . . . . xi In This Guide . . . . . . . . . . . . . . . . . . . . . . . . xi Other Sources of Information . . . . . . . . . . . . . . . . . . xii Meru Publications . . . . . . . . . . . . . . . . . . . . . xii External References . . . . . . . . . . . . . . . . . . . . xii Typographic Conventions . . . . . . . . . . . . . . . . . . . xii Contacting Meru . . . . . . . . . . . . . . . . . . . . . . xiii Customer Services and Support . . . . . . . . . . . . . . . . xiii Chapter 1 Chapter 2 Meru Access Points and Radio Switch . . . . . . . . . . . . . 1 Meru Access Point AP300 Series . . . . . . . . . . . . . . . . . Meru Access Point AP200 Series . . . . . . . . . . . . . . . . . Meru Access Point AP150 Series . . . . . . . . . . . . . . . . . Meru Access Point OAP180 . . . . . . . . . . . . . . . . . . . Radio Switch RS4000 . . . . . . . . . . . . . . . . . . . . . RS4000 Hardware Features and Specifications . . . . . . . . . . . Installing the AP300 . . . . . . . . . . . . . . . . . . . . 11 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . 11 Unpack the AP300 . . . . . . . . . . . . . . . . . . . . . . 12 Determine Power Requirements . . . . . . . . . . . . . . . . . 13 Installation Requirements . . . . . . . . . . . . . . . . . . . 13 Additional Equipment . . . . . . . . . . . . . . . . . . . 14 Install the AP300 . . . Select a Location . . Attach the Antennas . Install the Access Point 15 15 15 19 Check AP300 LED Activity . . . . . . . . . . . . . . . . . . . 24 Chapter 3 Installing the AP200 . . . . . . . . . . . . . . . . . . . . 27 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . 27 Unpacking the AP200 . . . . . . . . . . . . . . . . . . . . . 27 Installation Requirements . . . . . . . . . . . . . . . . . . . 28 Installing the Access Points . . . Selecting a Location . . . . Attaching the AP200 Antennas Mounting the Access Point . . © 2008 Meru Networks, Inc. 30 30 31 31 Contents iii Chapter 4 Chapter 5 Chapter 6 iv Where to Go From Here . . . . . . . . . . . . . . . . . . . 40 Checking LED Activity . . . . . . . . . . . . . . . . . . . . Ethernet Connector LEDs . . . . . . . . . . . . . . . . . . AP200 Status LEDs . . . . . . . . . . . . . . . . . . . . 41 41 42 Installing the OAP180 . . . . . . . . . . . . . . . . . . . . 45 Safety Precautions . . . . . . . . . . . . . . . . . . . . . 45 Unpacking the OAP180 . . . . . . . . . . . . . . . . . . . . 46 Installation Requirements. . . . . . . . . . . . . . . . . . . 46 Installing the Access Points . . Selecting a Location . . . Test Basic Link Operation . Mounting the Access Point . Connect Antennas and Ground Align Antenna. . . . . . 47 47 49 49 51 54 Where to Go From Here . . . . . . . . . . . . . . . . . . . 55 Checking LED Activity . . . . . . . . . . . . . . . . . . . . Antenna Gain Recommendations . . . . . . . . . . . . . . . 55 56 . . . . . . . . Wire . . to . . . . . . . . . . . . OAP180 . . . Installing the AP150 . . . . . . . . . . . . . . . . . . . . . 59 Safety Precautions . . . . . . . . . . . . . . . . . . . . . 59 Unpacking the AP150 . . . . . . . . . . . . . . . . . . . . 59 Installation Requirements. . . . . . . . . . . . . . . . . . . 60 Installing the Access Points . . Selecting a Location . . . Attaching the AP150 Antennas Mounting the Access Point . 62 62 63 63 Where to Go From Here . . . . . . . . . . . . . . . . . . . 69 Checking LED Activity . . . . . . . . . . . . . . . . . . . . AP150 Status LEDs . . . . . . . . . . . . . . . . . . . . 70 70 Installing the RS4000 . . . . . . . . . . . . . . . . . . . . 73 Safety Precautions . . . . . . . . . . . . . . . . . . . . . 73 Unpacking the RS4000 . . . . . . . . . . . . . . . . . . . . 73 Installation Requirements. . . . . . . . . . . . . . . . . . . About an Hoffman/NEMA Enclosure Installation . . . . . . . . . . Optimum Antenna Positioning and Placement . . . . . . . . . . 74 76 77 Installing the RS4000 . . . . . . . . . . Mounting the RS4000 . . . . . . . . . Placing and Positioning the Antenna . . . . Hoffman/NEMA Enclosure RS4000 Installation. 78 78 87 89 Where to Go From Here . . . . . . . . . . . . . . . . . . . 91 Checking LED Activity . . . . . . . . . . . . . . . . . . . . RS4000 Status LEDs . . . . . . . . . . . . . . . . . . . . 92 92 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . 95 Wireless Interface . . . . . . . . . . . . . . . . . . . . . . 95 Ethernet Interface . . . . . . . . . . . . . . . . . . . . . . 97 Physical Appendix B . . . . . . . . . . . . . . . . . . . . . . . . . 97 AP Accessories . . . . . . . . . . . . . . . . . . . . . . . 99 AP300 Accessories . . . . AP300 PoE Devices . . AP300 Power Supply . . AP300 Antennas . . . AP300 Mounting Options. Appendix C Appendix D Appendix E . . 99 . . 99 . . 99 . 100 . 100 AP200 Accessories . . . . . . . . . . . . . . . . . . . . . 101 OAP1800 Accessories . . . . . . . . . . . . . . . . . . . . 101 AP150 Accessories . . . . . . . . . . . . . . . . . . . . . 101 Mounting Bracket Stencils . . . . . . . . . . . . . . . . . . 103 AP150 and AP300 Rev A Mounting Bracket Stencil . . . . . . . . . . 103 AP300 Rev B Mounting Bracket Stencil . . . . . . . . . . . . . . 105 Cautions and Warnings . . . . . . . . . . . . . . . . . . . 107 Cautions . . . . . . . . . . . . . . . . . . . . . . . . 107 Warnings . . . . . . . . . . . . . . . . . . . . . . . . 110 Regulatory Information . . . . . . . . . . . . . . . . . . . 115 For OAP180 Radio . EMC. . Safety . 115 115 115 115 USA . . . . . . . . . . . . . . . . Underwriters Laboratories . . . . . . . FCC Radiation Exposure Statement . . . . Radio Frequency Interference Requirements 116 116 117 117 Canada. Industry Canada (IC) . . . . . . . . . . . . . . . . . 119 Europe—EU Declaration of Conformity and Restrictions . . . . . . . . IEEE 802.11a Restrictions . . . . . . . . . . . . . . . . . EEE 802.11b/g Restrictions. . . . . . . . . . . . . . . . . 121 124 124 Japan . . . . . . . . . . . . . . . . . . . . . . . . . Singapore. . . . . . . . . . . . . . . . . . . . . . . 124 125 Manufacturing Information . . . . . . . . . . . . . . . . . . 125 AP300 Plenum Requirements . . . . . . . . . . . . . . . . . 126 © 2008 Meru Networks, Inc. Contents vi Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft List of Figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure © 2008 Meru Networks, Inc. 1 Meru AP 300 ........................................................................ 2 2 Access Point AP200 ............................................................... 3 3 Access Point AP150 ............................................................... 5 4 Rugged OAP180 Access Point .................................................... 6 5 Radio Switch RS4000 .............................................................. 7 6 AP320, AP311 or AP302 Antennas 1-6 .......................................... 16 7 AP310 Antennas 1-3 ............................................................... 17 8 AP300 Antenna Connection ...................................................... 17 9 Remote Antenna Mount .......................................................... 18 10 Mounting the AP300 to a Suspended Ceiling Rail ........................... 21 11 AP300 Mounted Above a Suspended Ceiling ................................. 22 12 Attaching the Mounting Bracket to the Box Hanger ........................ 23 13 AP300 Status LEDs ............................................................... 24 14 AP200 Mounting Bracket ........................................................ 28 15 AP200 Antenna Connection ..................................................... 32 16 AP200 Connector Panel ......................................................... 33 17 AP200 Bracket .................................................................... 33 18 Aligning the AP200 with the Bracket ......................................... 34 19 Sliding the AP200 into the Bracket ............................................ 35 20 Mounting the AP200 to a Suspended Ceiling Rail ........................... 36 21 Mounting the AP200 Above a Suspended Ceiling ............................ 38 22 Box Hanger Mounting Bracket Holes .......................................... 38 23 Attaching the Mounting Bracket to the Box Hanger ........................ 39 24 RJ-45 LEDs ........................................................................ 41 25 AP200 Status LEDs ............................................................... 42 26 OAP180 Outdoor Access Point ................................................. 46 27 Sample Physical Layout ......................................................... 47 28 Square Mounting Bracket Attaches to Bottom of OAP180 ................. 49 29 Brackets Attached to a Pole ................................................... 50 30 Connect the Antenna Cables ................................................... 52 31 OAP180 LEDs ...................................................................... 56 32 AP150 with Mounting Bracket .................................................. 60 33 AP150 Antenna Connection ..................................................... 64 34 AP150 Connector Panel ......................................................... 64 35 AP150 Bracket .................................................................... 66 36 Aligning the AP150 with the Bracket ......................................... 67 37 Mounting the AP150 to a Suspended Ceiling Rail ........................... 68 38 AP150 Status LEDs ............................................................... 70 39 RS4000 Package Contents ...................................................... 74 40 Open NEMA Box Showing Mounting Holes .................................... 77 41 Bracket Attached to RS4000 ................................................... 79 42 RS4000 Bracket Mounting ....................................................... 80 43 RS4000 with Antenna Attached ................................................ 81 44 Mounting the RS4000 Below a Suspended Ceiling Rail ..................... 82 List of Figures vii Internal Use Only—Beta Draft Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 45 46 47 48 49 50 51 52 53 54 RS4000 with Antenna Attached ................................................ 83 Mounting the RS4000 Above a Suspended Ceiling ........................... 84 Box Hanger Mounting Bracket Holes .......................................... 85 Attaching the Mounting Bracket to the Box Hanger ........................ 85 RS4000 with Antenna Attached ................................................ 86 RS4000 180o Directional Antenna ............................................. 87 Antenna Mounting Arm with Wall Bracket (shown attached) ............. 88 Antenna Ceiling Tile Rail Base ................................................. 88 RS4000 and Antenna Installed in NEMA Enclosure .......................... 90 RS4000 Status LEDs .............................................................. 92 viii Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft List of Tables Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table Table © 2008 Meru Networks, Inc. 10 11 12 13 14 15 16 17 18 RS4000 Hardware Features .............................................. Meru AP300 Radios and Antennas ...................................... AP300 Power Options ..................................................... AP300 Installation Items ................................................. Antenna Use for AP320, AP311, and AP302 (Dual Radio Units) ..... Antenna Use for AP310 (Single Radio Unit)............................ AP300 LED Descriptions .................................................. AP200 Installation Items ................................................. AP200 Installation Tools ................................................. AP200 LED Descriptions ................................................. AP200 Controller Status Information ................................. Antenna Gain ............................................................. AP150 Installation Items ................................................ AP150 Installation Tools ................................................ AP150 LED Descriptions ................................................. RS4000 Installation Tools ............................................... RS4000 LED Descriptions ................................................ Wireless Interface Specifications ..................................... 12 13 14 16 17 25 29 30 43 43 57 61 62 71 76 93 95 List of Tables ix Internal Use Only—Beta Draft Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft About This Guide This guide describes the features and provides installation instructions for the Meru Access Points, which includes the AP200, OAP180, and AP150 models, and the Radio Switch RS4000. The term access point is used interchangeably throughout this document to apply to any model when there are no differences among the models. Audience This guide is intended for persons installing the Meru Wireless LAN System Access Point (AP) and Radio Switches. In This Guide This guide includes the following chapters: z Chapter 1, “Meru Access Points and Radio Switch” z Chapter 6, “Installing the RS4000” z Chapter 2, “Installing the AP300” z Chapter 3, “Installing the AP200” z Chapter 4, “Installing the OAP180” z Chapter 5, “Installing the AP150” z Appendix A, “Specifications” z Appendix D, “Cautions and Warnings” z Appendix E, “Regulatory Information” z Appendix D, “Channels” z Appendix C, “Mounting Bracket Stencils” z Appendix B, “AP Accessories” © 2008 Meru Networks, Inc. About This Guide xi Internal Use Only—Beta Draft Other Sources of Information Additional information is available in the following Meru publications, Web site, and external references. Meru Publications z Meru System Director Release Notes z Meru System Director Getting Started Guide z Meru Controller Installation Guide z Meru System Director Command Reference z Meru System Director Configuration Guide External References z Stevens, W. R. 1994. TCP/IP Illustrated, Volume 1, The Protocols. Addison-Wesley, Reading, Mass. z Gast, M.S. 2002. 802.11 Wireless Networks, The Definitive Guide. O’Reilly and Associates, Sebastopol, Calif. Typographic Conventions This document uses the following typographic conventions to help you locate and identify information: Note: Provides extra information, tips, and hints regarding the topic. Caution! Identifies important information about actions that could result in damage to or loss of data, or could cause the application to behave in unexpected ways. Warning! Identifies critical information about actions that could result in equipment failure or bodily harm. © 2008 Meru Networks, Inc. About This Guide xii Internal Use Only—Beta Draft Contacting Meru You can visit Meru Networks, Inc. on the Internet at this URL: http://www.merunetworks.com Customer Services and Support For assistance, contact Meru Customer Services and Support 24 hours a day at +1-888-637-8952 (+1-888-Meru-WLA(N)) or +1-408-215-5305. Email can be sent to support@merunetworks.com. Meru Networks, Inc. Customer Services and Support provide end users and channel partners with the following: z Telephone technical support z Software update support z Spare parts and repair service RMA Procedures Contact Meru Customer Services and Support for a Return Material Authorization (RMA) for any Meru equipment. Please have the following available when making a call: z Company and contact information z Equipment model and serial numbers z Meru software release and revision numbers (for example, 3.0.0-35) z A description of the symptoms the problem is manifesting z Network configuration © 2008 Meru Networks, Inc. About This Guide xiii Internal Use Only—Beta Draft © 2008 Meru Networks, Inc. About This Guide xiv Internal Use Only—Beta Draft Chapter 1 Meru Access Points and Radio Switch Meru Access Points and Radio Switches contain radio devices that communicate with the Meru Controller and form the wireless LAN (WLAN). The Meru Controller, Radio Switches, and Access Points connect to the site’s wired LAN through wired switches. Wireless clients associate with the Radio Switches and Access Points as they roam throughout the WLAN. As such, the Meru Wireless LAN System is an extension of the wired LAN, providing the wireless benefits of client mobility, enhanced access, and dynamic network configuration. Meru AP Meru Access Point AP300 Series The AP300 Access Point delivers high performance, full-speed, Wi-Fi certified 802.11n based on draft 2.0 connectivity while simultaneously supporting legacy 802.11a/b/g devices. Meru AP300 is available in these configurations: — AP320: Two dual-band 802.11n radios with 3x3 MIMO — AP310: Single dual-band 802.11n radio with 3x3 MIMO © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft — AP311: Single dual-band 802.11n radio and single 802.11a/b/g radio (AP320 upgradeable) — AP302: Two dual-band 802.11a/b/g radios (AP320 upgradeable) Features for the AP300 include: z 802.11n support with channel bonding in both 2.4GHz and 5GHz frequency bands. Channel bonding combines two 20Mhz channels into a single-wide 40Mhz channel for increased throughput. z Dual-band external antenna options optimized for MIMO mode z Plug and Play deployment using centralized controller platforms z Multi-layered security including standard WPA2, 802.11i security such as automatic traffic inspection z Each of these Access points may be powered by a standard 802.3af PoE device. z Air Traffic Control technology for 802.11n devices and legacy a/b/g devices z 3x3 MIMO with 3 chains and 3 receive chains, delivering full 300Mbps data rates using 2 spatial streams z For AP302 and AP311, the a/b/g radio software upgrades to 802.11n for maximum investment protection. z Channel span architecture which requires no channel planning or configuration z Six standard multiband, omni-directional antennas for AP302, AP320 and AP311. Three standard multiband, omni-directional antennas for AP310. z Powered by 5 volt DC input, 802.3af compliant PoE device, or draft 802.3at compliant PoE device. Figure 1: Meru AP 300 © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft Meru Access Point AP200 Series The Meru Access Point AP200 series provides two models that conform to the specifications provided by the IEEE 802.11a and 802.11g protocols and provide backward compatibility for the 802.11b protocol. An AP200 works with most standard Wi-Fi clients. z The AP201 houses a single 802.11a/b/g radio device z The AP208 supports a maximum of two radio devices that can simultaneously run two protocols (802.11b, g or b/g on interface 1 and 802.11a on interface 2). Alternately the second radio can be configured to run as an RF monitor to the Meru Controller, providing real-time status of RF activity to optimize the wireless network. The Meru Access Point AP200 series (referred hereafter as the AP200, unless specifically referring to the AP201 or AP208) is housed in a metal case with a plastic removable cover. As such, it can be used for plenum installations when the plastic cover is removed. 00 00109 AP2 Figure 2: Access Point AP200 © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft Meru Access Point AP150 Series Note: Meru Access Point AP150 models may have different revisions, but functionally they are the same, and all are referred to as the AP150 series. Hereafter in this document, all AP150 series models are referred to as the AP150. The AP150 has two 802.11 radios for simultaneous 802.11a and 802.11b/g WLAN access. It is an ideal option for enterprise-wide data-only WLAN implementations and small-sized converged data and voice WLAN implementations. The AP150 works in conjunction with Meru Controller products and can be easily integrated into existing Layer 2 and Layer 3 wired network environments to provide enterprise-grade Wi-Fi access with multi-layered security options, basic VoWLAN support, centralized configuration, troubleshooting tools, remote management and RF visualization capabilities. The Meru Access Point AP150 supplies the following features: z Dual 802.11b/g and 802.11a radios z Simultaneously support for 802.11b, 802.11g, and 802.11a clients z Contention Management for high density of data clients z Basic VoWLAN QoS support for small density of voice clients z Multiple ESSIDs with individual security policies to ensure separation of different user groups or dynamic VLAN assignment per user based on RADIUS credentials z Zero configuration required at the access point; the installation procedure is a simple plug-n-play z Automatic AP discovery, configuration z Intelligent load balancing of clients z Layer 2 or 3 connectivity for flexible deployment options z Locking mechanism secures access point when mounted in public areas © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft RAD IO1 RAD IO2 PW 00175 LAN Figure 3: Access Point AP150 Meru Access Point OAP180 The OAP180 Rugged Access Point with dual 802.11a/bg radios is designed to provide secure Wi-Fi connectivity to outdoor locations such as campuses, parking lots, and pole tops, or to harsh indoor locations such as breweries, food processing plants or warehouses. The OAP180 supports the following features: z Simultaneous support for 802.11a, 802.11b, and 802.11g clients using dual 802.11a and 802.11b/g radios z Full support of System Director features z Automatic AP discovery and configuration z No channel planning required with single channel installations z Intelligent load balancing of clients z PoE (Power over Ethernet) support z RoHS compliant © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft z Locking mechanism for security when mounted in public areas Figure 4: Rugged OAP180 Access Point Radio Switch RS4000 The Radio Switch RS4000 enables high-capacity enterprise-class wireless LAN connectivity with full support of standard 802.11 security and network management features. Each RS4000 contains four 802.11 radios (two 802.11b/g, two 802.11a) for high data and voice throughput – an essential requirement for high user-density environments with several simultaneous users. Classrooms and convention halls are typical deployment applications of the Radio Switch. Deploying the Radio Switch is easy— as with wireless access points, the Radio Switch can be installed wherever wireless coverage is needed. For large buildings with multiple rooms and floors, more than one Radio Switch can be installed to cover the desired area. Wireless users can seamlessly roam from one Radio Switch to another, getting high-capacity WLAN access throughout the wireless enterprise enabled with multiple Radio Switches. The RS4000 also balances radio traffic across its RF channels and resolves contention within each RF channel such that users receive a switched wireless experience with dedicated bandwidth to execute a variety of applications ranging from web browsing and VoIP mobility to multimedia streaming. © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft The RS4000 ships with either a high-gain omni-directional indoor antenna or a 180degree directional indoor antenna that aggregates and layers radio transmissions from each of the built-in radios. The antenna can broadcast every channel available to blanket the area around the Radio Switch, yet avoid interference and contention. This simplifies deployment efforts by eliminating the need for additional antennas for each radio. More importantly, RF channel planning efforts are greatly simplified. Using the RS4000, wireless users experience the benefits of switching technology on Wi-Fi—dedicated bandwidth, traffic separation, and multi-service network support. The RS4000 can be deployed with up to two 802.11b/g and two 802.11a channels active on the radio interfaces. The 802.11b/g channels must be separated by a minimum of 8 channels (for example, channels 1 and 9), so the recommended set is channels 1 and 11, typically. The 802.11a channels must be separated by a minimum of 80MHz/16 channels for best performance (for example, channels 36 and 52). 00178 POWER RADIO II RADIO ET ETHERN Figure 5: Radio Switch RS4000 RS4000 Hardware Features and Specifications The RS4000 has four 802.11 radios (two 802.11a and two 802.11bg) that transmit and receive simultaneously on four different channels to increase the total available wireless bandwidth at a given area. The RS4000 connects to the LAN using one 10/100 Mbps Ethernet connection for each radio pair. The RS4000 is powered using two IEEE 802.3af POE connections, each with 15W power. © 2008 Meru Networks, Inc. Meru Access Points and Radio Switch Internal Use Only—Beta Draft Note: PoE must be provided on the first Ethernet connector (ETH1); the antenna cannot operate correctly without that power source. Power to the second Ethernet connector (ETH2 ) is optional; if not connected, two of the radios will not operate. The RS4000 works in conjunction with a wideband RF combination omni directional (WRC/OD) indoor antenna or a 180-degree directional indoor antenna. Only one antenna is needed for simultaneous operation of all radios of an RS4000 in both the 2.4GHz and 5GHz bands. The antenna must be connected to the Radio Switch using any one of the low-loss antenna cables provided in the antenna packaging. The following table lists the key hardware features of the RS4000. Table 1: RS4000 Hardware Features Feature 802.11 Connectivity Description Two 802.11b/g radios (2.4GHz) Two 802.11a radios (5 GHz) Ethernet Connectivity Two auto-sensing 10/100 Mbps ports, one for each radio pair Power Provided by two 802.3af POE connections, one for each radio pair (15W per connector) LEDs Power, Radio Activity, and Ethernet Activity LEDs per radio Dimensions 9.5" x 8.5" x 3.875" RS4000 has mounting brackets available for: Mounting Options © 2008 Meru Networks, Inc. Ceiling Mount Wall Mount Inside NEMA Enclosures (Hoffman, etc.) Meru Access Points and Radio Switch Internal Use Only—Beta Draft Radio Switch RS4000 Table 1: RS4000 Hardware Features Feature Description The RS4000 ships with either of these antennas: Antenna Wideband RF Combination/OmniDirectional (WRC/OD) Antenna. 5dBi gain. Indoor use. 180-degree directional indoor antenna 3’ low-loss cables (default option) Antenna Cables © 2008 Meru Networks, Inc. 6’ and plenum-rated cables (available option) Meru Access Points and Radio Switch Internal Use Only—Beta Draft Radio Switch RS4000 10 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Chapter 2 Installing the AP300 This chapter describes how to install and configure the Meru AP300. It contains the following sections: z Safety Precautions z Unpack the AP300 z Determine Power Requirements z Installation Requirements z Install the AP300 z Check AP300 LED Activity Safety Precautions IMPORTANT—Read and follow the regulatory instructions in Appendix E before installing and operating this product. If an optional power supply is used, it should be a UL Listed power supply, marked Class 2 or LPS, and rated minimum 5 Vdc, 3A. © 2008 Meru Networks, Inc. Installing the AP300 11 Unpack the AP300 The Meru AP300 series consists of the four models shown below. Depending on which model you are installing, you will have either six or three antennas. The drawings in this chapter show six antennas. Table 2: Meru AP300 Radios and Antennas Model Radio 1 (Ant4, Ant5, Ant6) Radio 2 (Ant1, Ant2, Ant3) AP320 a/b/g/n with 3 dual band omni-directional antennas a/b/g/n with 3 dual band omni-directional antennas AP311 a/b/g/n with 3 dual band omni-directional antennas a/b/g with 3 dual band omnidirectional antennas AP310 a/b/g/n with 3 dual band omni-directional antennas NA AP302 a/b/g with 3 dual band omnidirectional antennas a/b/g with 3 dual band omnidirectional antennas Confirm that the AP300 shipping package contains these items: z AP300 with attached mounting bracket z Six (AP320, AP311, AP302) or three (AP310) antennas © 2008 Meru Networks, Inc. Installing the AP300 12 Determine Power Requirements Your power requirements will vary, depending on which AP300 radios are deployed and what mode is used. See below. Table 3: AP300 Power Options AP300 Configuration Power Options 1 radio – a/b/g mode External power supply or PoE 802.3af 1 radio – n-mode External power supply or PoE 802.3af 2 radios – 1 a/b/g mode, 1 n mode 2 radios – both n mode 2 radios – both a/b/g mode For 2x2 MIMO mode, use either a power supply or PoE 802.3af. For 3x3 MIMO mode, use either a power supply or a PoE 802.3at. For 2x2 MIMO mode, use either a power supply or PoE 802.3af. For 3x3 MIMO mode, use either a power supply or a PoE 802.3at. External power supply or PoE 802.3af Installation Requirements An array of holes on the mounting bracket allows the AP300 to be mounted on the wall and over junction boxes or molly bolts. There are holes for passing the PoE Ethernet or external power supply cable through the bracket if the bracket is mounted on a junction box. A template of this bracket is included in Appendix E of this guide. The AP300 has a security cable slot so you can lock the AP300 with a standard security cable, such as those used to secure laptop computers. These two kits can be used to mount the AP300 from the ceiling: z Suspended Ceiling Rail Mounting Kit z Above Suspended Ceiling Mounting Kit (T-Bar Hanger) © 2008 Meru Networks, Inc. Installing the AP300 13 To complete AP300 installation, you need the items listed below. Table 4: AP300 Installation Items Installation Type Consumable Items Required Horizontal mounting None Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling Using existing third party brackets Two #6 x 2" wood screws for a wood stud; or Two #6 x 1½" metal screws for a metal stud Mounting bracket Two #6 x 1" screws Two #4-6 x 7/8" ribbed plastic wall anchors Mounting bracket Two caddy fasteners Two plastic spacers Two keps nuts (with attached lock washer) Mounting bracket Use included shoulder screws Additional Equipment A power source is needed to power the AP300. Available options are: z External ACC-AP300-PWR power supply z 802.3af compliant PoE device z Draft 802.3at compliant PoE device You can optionally add a remote antenna mount; see Install the Optional Remote Antenna Mount on the Ceiling. © 2008 Meru Networks, Inc. Installing the AP300 14 Install the AP300 Select a Location All AP300 interconnected equipment must be contained within the same building, including the interconnected equipment's associated LAN connection. In addition, the AP300 should be mounted in a location that meets the following conditions: z Relatively unobstructed access to the stations the AP serves. Select a location with minimal physical obstructions between the AP and the wireless stations. In an office with cubicles, mounting the APs below a hanging ceiling (plenum is supported) or the wall near the ceiling provides the least obstructed communications path. For an external power supply connection, ensure the power source is near to where the AP300 will be mounted. z Access to wall outlet or a to a Power over Ethernet (PoE) connection to the network switch servicing the controller. Most installations receive the best coverage using the following guidelines: z Install APs toward the center of the building. z Do not install APs near metal objects, such as heating ducts, metal doors, or electric service panels. z Relative to the ground, orient the antenna up or down, not sideways. Note: The previous guidelines are general guidelines. Each site has its own unique environment. Place access points accordingly. Attach the Antennas The AP320, AP311, and AP302 have six external antenna ports, labeled 1 - 6. These units only operate with six attached antennas, even though some configurations don’t use all six. Make sure that all external antennas and their associated wiring are located entirely indoors. The external antennas are not suitable for outdoor use. Figure 6 illustrates the recommended antenna configuration. © 2008 Meru Networks, Inc. Installing the AP300 15 Figure 6: AP320, AP311 or AP302 Antennas 1-6 The following antenna connections are used during operation of the AP320, AP311, and AP302. Table 5: Antenna Use for AP320, AP311, and AP302 (Dual Radio Units) Mode Radio 1 Uses Radio 2 Uses 802.11abgn 3x3 MIMO Ant4, Ant5, Ant6 Ant1, Ant2, Ant3 802.11abgn 2x2 MIMO Ant4, Ant6 Ant1, Ant3 802.11abg Ant4 Ant1 The AP310 has six external antenna ports labeled 1 - 6. However, AP310 uses a maximum of three antennas and the unused antenna connectors are blocked. Figure 7 illustrates the recommended antenna configuration for the AP310. © 2008 Meru Networks, Inc. Installing the AP300 16 Figure 7: AP310 Antennas 1-3 The following antenna connections are used during operation of the AP310. Table 6: Antenna Use for AP310 (Single Radio Unit) Mode Radio 1 Uses Radio2 Uses 802.11abgn 3x3 MIMO Ant1, Ant2, Ant3 NA 802.11abgn 2x2 MIMO Ant1, Ant3 NA 802.11abg Ant1 NA The attached antennas must be the same model; if you replace one antenna, replace them all. Attach the antennas to the connectors on the AP300 (see Figure 8). Rotate the knurled ring at the base of the antenna clockwise to attach the antenna. The ring should be finger-tight. Figure 8: AP300 Antenna Connection antenna connector © 2008 Meru Networks, Inc. Installing the AP300 17 Caution! When changing the orientation of the antennas, be sure to slightly loosen the knurled ring before moving the antenna. Retighten the ring afterward. Otherwise, you might damage the internal cabling in the AP. Install the Optional Remote Antenna Mount on the Ceiling Use an optional Remote Antenna Mount for one or both AP300 radios to remotely connect the AP300 antennas. The 3*3 SMA Antenna Stand allows you to relocate either your current antennas or the Meru's High Gain Dipole Antennas to a location with clearer signal paths to the other devices in your wireless network. The Remote Antenna Mount can be placed either below the ceiling tile or on the wall. The default orientation for the Mount is suitable for a ceiling mount, but you can attach the Mount to a wall with some modifications. Use one mount per radio; for example AP310 needs one unit, and AP320 needs two units.The Antenna Mount uses low-loss Plenum rated LMR195 cable and SMA connectors. Figure 9: Remote Antenna Mount The remote antenna mount kit includes: z Antenna stand with attached cable. The three antenna SMA female connectors on the Antenna Mount support AP300 antenna diversity. This feature gives the client the ability to automatically choose the antenna receiving the strongest signal. z Triangular ceiling mount clip for attaching to hanging ceiling (includes bolt assembly) z Three self-adhesive pads for the bottom of the unit (over the screws) z Two wall mount screws with anchors z Ceiling Mount Template z Installation diagram © 2008 Meru Networks, Inc. Installing the AP300 18 To connect the remote antenna mount to the ceiling, refer to the enclosed installation diagram while following these steps: 1. Attach the shorter end of the screw to the center hole on the back of the Antenna Mount. 2. Remove the designated ceiling tile. 3. Using the template, drill holes in the ceiling tile. 4. Replace the ceiling tile. 5. Remove a ceiling tile adjacent to the newly drilled tile for access purposes. 6. Feed the Antenna Mount cable through the larger hole in the ceiling tile until the Antenna Mount is flush with the ceiling. The screw should now be visible above the ceiling tile (through the second hole). 7. Place the triangular plate above the ceiling tile with the screw aligned through the plate. 8. Drop the washer onto the screw and tighten the bolt. The Antenna Mount is now connected to the ceiling. 9. Replace the adjacent tile. 10. Connect the three Remote Antenna Mount cables to the appropriate connectors on the AP300. Be sure to connect the three antennas that correspond to one radio. See Table 5 and Table 6 to determine the cable connection configuration. 11. Attach three antennas that shipped with AP300 to the three connectors on the triangular remote device. See Figure 9. Install the Optional Antenna Mount on a Wall 1. Reorient the cable on the Remote Antenna Mount by removing the three screws on the back, removing the small cover, reorienting the cable and then replacing the three screws. Discard the small cover. 2. Connect the three Remote Antenna Mount cables to the appropriate connectors on the AP300. Be sure to connect the three antennas that correspond to one radio. See Table 5 and Table 6 to determine the cable connection configuration. 3. Attach three antennas that shipped with AP300 to the three connectors on the triangular remote device. See Figure 9. Install the Access Point The AP300 ships with a detachable mounting bracket. The AP300 is designed to be compatible with brackets supplied by Meru and by other vendors. The AP300 mounts directly on the AP150 mounting bracket. If you are replacing AP300s, the AP300 bracket can be mounted on the old AP300 bracket with included shoulder screws; you don’t need to remove the old brackets. AP300 can also be directly mounted on third-party brackets. You can mount an AP300 in the following ways: z Mount AP300 Horizontally on a Shelf z Mount AP300 Vertically on a Wall z Mount AP300 Below a Suspended Ceiling z Mount AP300 Above a Suspended Ceiling (Plenum) © 2008 Meru Networks, Inc. Installing the AP300 19 Mount AP300 Horizontally on a Shelf When mounting an AP300 horizontally, remove the mounting bracket. Be sure to position the antennas vertically when an AP300 sits on a surface. See Figure 1. Mount AP300 Vertically on a Wall Note: If you are replacing AP150s, you can use the existing brackets: the AP150 and AP300 use the same bracket. If you are replacing AP300s, the AP300 bracket can be attached to the old bracket with included shoulder screws; you don’t have to remove the old brackets. This bracket will also mount seamlessly into the Proxim AP4000 bracket and standard Cisco brackets. To mount an AP300 on a wall: 1. Using the bracket holes as a guide, mark the location on the wall for the two AP bracket mounting screws. If possible, center the mounting screws on a wall stud. If you do not center the mounting screws on a wall stud, use plastic wall anchors. 2. Drill holes at the locations you marked: — 3/16-inch holes if you are using plastic anchors — 1/8-inch holes if you are using only the screws 3. If you are using plastic anchors, install them in the holes. 4. Screw in the screws most of the way. 5. Mount the bracket on the screws, placing the circular portion of the keyhole mounts over the screw heads and sliding the bracket down. 6. Connect the Ethernet cable to the switch and to the AP300 Ethernet port shown in Figure 2. 7. If you are not using a PoE device, connect an external power supply to the power connector and plug it into the wall. Mount AP300 Below a Suspended Ceiling The optional suspended ceiling mounting kit allows the AP300 mounting bracket to attach to suspended ceiling T-rails (see Figure 10). Note: To comply with NEC code, attach a grounding wire to any of the screws used to attach the AP300 to the mounting bracket. © 2008 Meru Networks, Inc. Installing the AP300 20 Figure 10: Mounting the AP300 to a Suspended Ceiling Rail To mount an AP300 below a suspended ceiling: 1. Determine the location on the ceiling rail where the AP will be mounted and remove the ceiling tiles. 2. Place each of the two caddy fasteners on the ceiling T-rail and twist to attach to the rail. 3. Adjust the distance between the caddy fasteners by using the mounting bracket holes as a guide. 4. Tighten the caddy fasteners in place using a standard screwdriver. Do not overtighten. 5. Place each spacer on the caddy fastener stud. The spacer legs should contact the ceiling T-rail. 6. Align the mounting bracket keyholes with the caddy fastener studs and slide the AP300 to the narrow end of the hole. 7. Attach a keps nut to each caddy fastener stud and hand tighten. Do not overtighten. 8. Align the AP300 mounting posts over the circular portion of the keyhole mounts, push the AP in and slide the AP down until it engages with the locking detents (see Figure 10). You should hear it snap in place. 9. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 8), orient the antenna and then retighten the ring. 10. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector. Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port. © 2008 Meru Networks, Inc. Installing the AP300 21 Mount AP300 Above a Suspended Ceiling (Plenum) The optional T-bar box hanger mounting kit allows the AP300 to be mounted above suspended ceiling T-rails (see Figure 11). The installation attaches the T-bar box hanger to the ceiling rails using clips. The AP300 attaches to the mounting bracket that is attached to the T-bar box hanger. The AP300 with the metal enclosure exposed meets the requirements for fire resistance and low smoke-generating characteristics required by Section 300-22(C) of the National Electrical Code (NEC) for installation in a building’s environmental air space. You may need to modify thicker tiles to support this installation. Warning! When installed in air-handling spaces, such as above a suspended ceiling, power the AP300 only with a PoE, not a power supply. Warning! Use Ethernet cable that meets the requirements for operating in plenums and environmental air space (in accordance with Section 300-22(C) of the NEC). Warning! Any Fast Ethernet (FE) cables installed in air-handling spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and airhandling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum). Figure 11: AP300 Mounted Above a Suspended Ceiling Height adjustment screw Bracket mounting clip Mounting bracket T-bar hanger Height adjustment screw Access Point T-rail clips Suspended ceiling T-rail 1. Determine the location on the ceiling rails where the AP will be mounted and remove the ceiling tile. 2. Unpack the T-bar hanger kit and unfold the legs of the T-bar hanger. © 2008 Meru Networks, Inc. Installing the AP300 22 3. Locate the bracket mounting clip holes on the mounting bracket (see Figure 11). One hole attaches the bracket perpendicular to the box hanger; the other mounts the bracket parallel to the box hanger. 4. Attach the U-joint of the clip to the T-bar and snap in place (see Figure 12). Figure 12: Attaching the Mounting Bracket to the Box Hanger 00104 5. Pass the long end clip through the large center hole to the underside of the mounting bracket clip and then attach the bracket to the clip using the supplied screw (see Figure 12 for orientation). 6. Hold the AP300 next to the mounting bracket to estimate the height of the T-bar box hanger to provide enough clearance for the external antennas, which should be pointing down. 7. Adjust the height of the box hanger using the height adjusting screws (see Figure 10). 8. Clip the box hanger T-rail clips to the ceiling rails, making sure they are securely attached. 9. Connect a drop wire to a building structural element and through the hole provided in the bracket mounting clip. The U.S. National Electrical Safety Code requires this additional support. 10. Connect the posts of the AP300 to the three keyholes of the mounting bracket and slide into the keyhole, ensuring the locking detent is engaged. You will hear a click. 11. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 8), point the antenna down, then retighten the ring. 12. Connect one end of the PoE Ethernet cable to the Ethernet connector, shown in Figure 11. 13. Check that the AP300 is operating correctly before replacing the ceiling tile to the ceiling. Verify correct operating using the LEDs, as shown in Check AP300 LED Activity. Mount AP300 in a Hoffman Enclosure To mount an AP300 in a Hoffman enclosure, follow these steps: 1. Place AP300 upside down on a soft flat surface. 2. Remove and discard the wall/ceiling mounting bracket (650-00064) if installed. © 2008 Meru Networks, Inc. Installing the AP300 23 3. Remove and discard the four rubber feet. 4. If the unit has white antennas, remove them and attach the black antennas provided. 5. Position the Hoffman bracket (650-00128) onto the back of the AP300 with the four Hoffman mounting screws facing downwards. 6. Using a Phillips screw driver, attach the bracket using the two supplied 6-32 3/16 SEMS screws (66500018). 7. Flip the assembly over and mount into the Hoffman enclosure, attach the Ethernet cable to the AP300 rotating the assembly to allow ease of dressing the Ethernet cable within the enclosure. 8. Using a Phillips screw driver, tighten the four bracket screws to the enclosure. 9. Adjust the antennas as needed. Check AP300 LED Activity When the AP300 is first connects to the controller and any time the access point is rebooted, the AP initializes with and then is programmed by the controller. When the AP is first powered up, all LEDs are green. Thereafter, the Status LED color reflects the various operating states described in Table 7. After the AP300 is connected, check the status of the LEDs. Figure 13: AP300 Status LEDs The functions of the five LEDs are described below. © 2008 Meru Networks, Inc. 00217 Installing the AP300 24 Check AP300 LED Activity Table 7: AP300 LED Descriptions LED Power Function off—no power green—presence of power off—no power green—booting stage 1 blinking green and off—booting stage 2 Status blinking green and white—discovering the controller blinking green and blue—downloading a configuration from the controller blinking blue and off—AP is online and enabled, working state blinking red and yellow—failure; consult controller for alarm state off—no power or no link LAN green—link status OK (at any speed) green/blinking—activity (at any speed) red—auto negotiation failure off—no radio present Radio 1 Radio 2 green—radio enabled green blinking—data activity yellow—disabled or in scanning mode red—failure © 2008 Meru Networks, Inc. Installing the AP300 25 Check AP300 LED Activity 26 Meru AP300 Installation Guide © 2008 Meru Networks, Inc. Chapter 3 Installing the AP200 This chapter describes how to physically install the AP200. It contains the following sections: z Safety Precautions z Unpacking the AP200 z Installation Requirements z Installing the Access Points z Where to Go From Here z Checking LED Activity Safety Precautions IMPORTANT—Read and follow the instructions in “Regulatory Information” on page 115 before installing and operating this product. Unpacking the AP200 As you unpack the AP200, confirm that the AP200 shipping package contains the items listed on your packing list. Shipments of the AP200 include a mounting bracket and mounting hardware for standard wall mounting. Optional mounting kits are available for mounting the AP200 above or below a hanging ceiling. The AP200 mounting studs are placed so they can be used with brackets supplied by other vendors or to replace an AP100. Note: The AP200 has a security cable slot so you can secure the AP200 with a standard security cable, such as those used to secure laptop computers. © 2008 Meru Networks, Inc. Installing the AP200 27 Installation Requirements An array of holes on the mounting bracket (see Figure 14) allows it to be mounted on the wall and over junction boxes or molly bolts. There are also holes for passing the PoE Ethernet or external power supply cable through the bracket if the bracket is mounted on a junction box or over the ceiling T-bar box hanger. Ceiling mount hole Access point mount Wall cable access Access point mount Locking detent Suspended ceiling cable access Ceiling mount hole 00100 Access point mount Figure 14: AP200 Mounting Bracket Installation Requirements The following recommended mounting locations provide the best reception for the AP200: z On a horizontal surface, such as a table or a desk z On a vertical surface, usually a wall z Below a hanging ceiling z Above a hanging ceiling tiles (this installation is supported only for the AP200 with the plastic enclosure removed) Warning! With plastic covers removed, this product is suitable for use in environmental air space in accordance with the Section 300-22(c) of the National Electric Code and Sections 2- 128.12 - 010 (3) and 12 - 100 of the Canadian Electrical Code. Part 1. C22. 1. For other countries, consult local authorities for regulations. 28 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installation Requirements To complete this installation, you need the items listed in Table 8. Table 8: AP200 Installation Items Installation Type Consumable Items Required Horizontal mounting None Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling Mounting above a ceiling tile (AP200 metal enclosure only) © 2008 Meru Networks, Inc. Two #6 x 2" wood screws for a wood stud; or Two #6 x 1½" metal screws for a metal stud Mounting bracket Two #6 x 1" screws Two #4-6 x 7/8" ribbed plastic wall anchors Mounting bracket Two caddy fasteners Two plastic spacers Two keps nuts (with attached lock washer) Mounting bracket Two T-rail clips One T-box hanger One bracket mounting clip Mounting bracket Installing the AP200 29 Installing the Access Points You need the tools listed in Table 9. Table 9: AP200 Installation Tools Installation Type Tools Required Horizontal mounting None Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling Mounting above a hanging ceiling (AP200 metal enclosure only) Drill 1/8"drill bit Screwdriver Drill 3/16" drill bit Screwdriver Screwdriver Wrench or pliers Wrench or pliers Screwdriver Installing the Access Points Selecting a Location The AP200 requires a location that meets the following: z Relatively unobstructed access to the stations the AP serves z Power over Ethernet (PoE) connection to the network switch servicing the controller. APs can obtain their power from 802.3af standard Power over Ethernet (PoE)-compatible network switch or PoE power injector installed between the switch and the AP200. Select a location with minimal physical obstructions between the AP and the wireless stations. In an office with cubicles, mounting the APs below a hanging ceiling or the wall near the ceiling provides the least obstructed communications path. For an external power supply connection, ensure the power source is near to where the AP200 will be mounted. 30 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points Most installations receive the best coverage using the following guidelines: Install APs toward the center of the building. z Do not install APs near metal objects, such as heating ducts, metal doors, or electric service panels. z Relative to the ground, orient the antenna up or down, not sideways. Note: The previous guidelines are general guidelines. Each site has its own unique environment. Place access points accordingly. The AP200 is only intended for installation in Environment A as defined in IEEE 802.3af. All interconnected equipment must be contained within the same building, including the interconnected equipment's associated LAN connection. Attaching the AP200 Antennas The AP200 is provided with external antenna ports. Make sure that all external antennas and their associated wiring are located entirely indoors. The external antennas are not suitable for outside use. If the AP200 does not have external antennas, attach the antennas to the connectors on the AP200 (see Figure 15). Rotate the knurled ring at the base of the antenna clockwise to attach the antenna. The ring should be finger-tight. Caution! When changing the orientation of the antennas, be sure to slightly loosen the knurled ring before moving the antenna. Retighten the ring afterward. Otherwise, you might damage the internal cabling in the AP. Mounting the Access Point You can mount an AP200 in the following ways: z Horizontally, as described in the “Horizontal Mounting” section. z Vertically, as described in the “Vertical Mounting” section. z Below a hanging ceiling, as described in the “Mounting Below a Suspended Ceiling” section. z Above a tiled hanging ceiling, as described in the “Mounting Above a Suspended Ceiling” section. © 2008 Meru Networks, Inc. Installing the AP200 31 Installing the Access Points Horizontal Mounting To horizontally mount an AP200: 1. Place the AP200 flat on the horizontal surface. 2. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 15), point the antenna straight up, then retighten the ring. ET HE RN ET 3.3 Antenna VD AN Turn clockwise to tighten 00110 T2 Figure 15: AP200 Antenna Connection 3. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 16. Note: For the AP201 and AP208 access points, a shielded Cat 5e (or greater) Ethernet cable must be used in order to comply with international electromagnetic emissions limits. If it is not practical to use shielded cables, contact Meru Support for a line filter, available at no charge, that may also be used to ensure compliance. Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port (see Figure 16). 32 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points CONSOLE 100/1000 Ethernet ETHERNET (Currently unsupported) Power Antenna 2 inlet 3.3 VDC ANT 1 00108 Antenna 1 (Reserved) Reset Console (Push to restore port default settings) ANT 2 Figure 16: AP200 Connector Panel Vertical Mounting To vertically mount an AP: 1. Using the bracket holes as a template, mark the location on the wall for the two AP bracket mounting screws. They are placed 4 ½ inches apart, center-to-center, one above the other. If you are not using plastic wall anchors, you must center the mounting screws on a wall stud. If you do not center the mounting screws on a wall stud, you must use plastic wall anchors. Ceiling mount hole Access point mount Wall cable access Access point mount Locking detent Suspended ceiling cable access Ceiling mount hole 00100 Access point mount Figure 17: AP200 Bracket © 2008 Meru Networks, Inc. Installing the AP200 33 Installing the Access Points 2. Drill holes at the locations you marked: — 3/16-inch holes if you are using plastic anchors — 1/8-inch holes if you are using only the screws 3. If you are using plastic anchors, install them in the holes. 4. Screw in the screws most of the way, so that the screw head is about 1/16 of an inch from the wall. 5. Mount the bracket on the screws, placing the circular portion of the keyhole mounts over the screw heads and sliding the bracket down. 6. Tighten the screws to secure the bracket. 7. Align the AP200 mounting posts over the circular portion of the keyhole mounts, push the AP in and slide the AP down until it engages with the locking detents. You should hear it snap in place. AP200 00115 Mounting bracket attached to wall Figure 18: Aligning the AP200 with the Bracket 34 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points 00112 Mounting bracket Figure 19: Sliding the AP200 into the Bracket 8. For external antennas, loosen the knurled ring at the base of each antenna (see Figure 15), point the antenna straight up, then retighten the ring. 9. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 16. Note: For the AP201 and AP208 access points, a shielded Cat 5e (or greater) Ethernet cable must be used in order to comply with international electromagnetic emissions limits. If it is not practical to use shielded cables, contact Meru Support for a line filter, available at no charge, that may also be used to ensure compliance. Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port. © 2008 Meru Networks, Inc. Installing the AP200 35 Installing the Access Points Mounting Below a Suspended Ceiling The optional suspended ceiling mounting kit allows the AP200 mounting bracket to attach to suspended ceiling T-rails (see Figure 20). Note: To comply with NEC code, attach a grounding wire to any of the screws used to attach the AP200 to the mounting bracket. Suspended ceiling T-rail Caddy fastener(s) Plastic spacer(s) Keps nuts with attached locking washer 00102 Mounting bracket Figure 20: Mounting the AP200 to a Suspended Ceiling Rail To mount an AP200 below a suspended ceiling: 1. Determine the location on the ceiling rail where the AP will be mounted and remove the ceiling tiles. 2. Place each of the two caddy fasteners on the ceiling T-rail and twist to attach to the rail. 3. Adjust the distance between the caddy fasteners by using the mounting bracket holes as a guide. 4. Tighten the caddy fasteners in place using a standard screwdriver. Do not overtighten. 5. Place each spacer on the caddy fastener stud. The spacer legs should contact the ceiling T-rail. 6. Align the mounting bracket keyholes with the caddy fastener studs and slide the AP200 to the narrow end of the hole. 7. Attach a keps nut to each caddy fastener stud and hand tighten. Do not overtighten. 36 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points 8. Align the AP200 mounting posts over the circular portion of the keyhole mounts, push the AP in and slide the AP down until it engages with the locking detents (see Figure 19). You should hear it snap in place. 9. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 15), point the antenna straight down, then retighten the ring. 10. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in (see Figure 16). Note: For the AP201 and AP208 access points, a shielded Cat 5e (or greater) Ethernet cable must be used in order to comply with international electromagnetic emissions limits. If it is not practical to use shielded cables, contact Meru Support for a line filter, available at no charge, that may also be used to ensure compliance. Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port. Mounting Above a Suspended Ceiling The optional T-bar box hanger mounting kit allows the AP200 to be mounted above suspended ceiling T-rails (see Figure 21). The installation attaches the T-bar box hanger to the ceiling rails using clips. The AP200 attaches to the mounting bracket that is attached to the T-bar box hanger. The AP200 antennas should point straight down for this type of installation. You may need to modify thicker tiles to support this installation. Warning! When installed in air-handling spaces, such as above a suspended ceiling, the AP200 is to be powered via PoE only (PoE is required). Warning! The AP200 with the metal enclosure exposed meets the requirements for fire resistance and low smoke-generating characteristics required by Section 30022(C) of the National Electrical Code (NEC) for installation in a building’s environmental air space. You must remove the plastic enclosure to reveal the plenum-rated AP200 metal case for installations above a suspended ceiling. Additionally, you must use Ethernet cable that meets the requirements for operating in plenums and environmental air space (in accordance with Section 300-22(C) of the NEC). © 2008 Meru Networks, Inc. Installing the AP200 37 Installing the Access Points Warning! Any Fast Ethernet (FE) cables installed in air-handling spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and airhandling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum). Height adjustment screw Bracket mounting clip Mounting bracket T-bar hanger Height adjustment screw Access Point 200 Antennas 00103 T-rail clips Suspended ceiling T-rail Figure 21: Mounting the AP200 Above a Suspended Ceiling To mount an AP200 above suspended ceiling rails: 1. Determine the location on the ceiling rails where the AP will be mounted and remove the ceiling tile. 2. Unpack the T-bar hanger kit and unfold the legs of the T-bar hanger. 3. Locate the bracket mounting clip holes on the mounting bracket (see Figure 22). One hole attaches the bracket perpendicular to the box hanger; the other mounts the bracket parallel to the box hanger. 00101 Mounting bracket holes Figure 22: Box Hanger Mounting Bracket Holes 38 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points 4. Attach the U-joint of the clip to the T-bar and snap in place (see Figure 23). 00104 Figure 23: Attaching the Mounting Bracket to the Box Hanger 5. Pass the long end clip through the large center hole to the underside of the the mounting bracket clip and then attach the bracket to the clip using the supplied screw (see Figure 23 for orientation). 6. Hold the AP200 next to the mounting bracket to estimate the height of the T-bar box hanger to provide enough clearance for the external antennas, which should be pointing down. 7. Adjust the height of the box hanger using the height adjusting screws (see Figure 20). 8. Clip the box hanger T-rail clips to the ceiling rails, making sure they are securely attached. 9. Connect a drop wire to a building structural element and through the hole provided in the bracket mounting clip. The U.S. National Electrical Safety Code requires this additional support. 10. Connect the posts of the AP200 to the three keyholes of the mounting bracket and slide into the keyhole (see Figure 19), ensuring the locking detent is engaged. You will hear a click. 11. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 15), point the antenna down, then retighten the ring. 12. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 16. © 2008 Meru Networks, Inc. Installing the AP200 39 Where to Go From Here Note: For the AP201 and AP208 access points, a shielded Cat 5e (or greater) Ethernet cable must be used in order to comply with international electromagnetic emissions limits. If it is not practical to use shielded cables, contact Meru Support for a line filter, available at no charge, that may also be used to ensure compliance. Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port. 13. Check that the AP200 is operating correctly before replacing the ceiling tile to the ceiling. Verify correct operating using the LEDs, as shown in Checking LED Activity. Where to Go From Here Now that the AP200 is installed, go to the Meru System Director Getting Started Guide for instructions on initializing the controller and connecting the controller and APs to the Ethernet switch to form the WLAN. Return to this chapter to check the status of the LEDs once the WLAN is operational. 40 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Checking LED Activity Checking LED Activity Access point status LEDs are provided on the Ethernet connector and on the face of the AP200. Ethernet Connector LEDs Link present Ethernet activity 00129 After the AP200 is connected, the LEDs near the RJ-45 connector should light, as shown in Figure 24. Figure 24: RJ-45 LEDs The green LED on the left blinks if any Ethernet activity is taking place. If there is no Ethernet activity, the LED is off. The LED on the right is solid green if an Ethernet link is present. If no Ethernet link is present or connectivity is lost, the LED is off. © 2008 Meru Networks, Inc. Installing the AP200 41 Checking LED Activity AP200 Status LEDs Four status LEDs on the face of the AP200 also light, as shown in Figure 25. .. RF2 RF1 STATUS POWER 00 00113 AP2 Figure 25: AP200 Status LEDs The functions of the status LEDs are described in Table 11. When the AP200 is first connected to the controller and any time the access point is rebooted thereafter, the AP initializes with and then is programmed by the controller. When the AP is first powered up, all LEDs are green. Thereafter, the Status LED (see Figure 25) color reflects the various operating states (Table 11). 42 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Checking LED Activity Table 10: AP200 LED Descriptions LED Function The status LED for Radio 2 is a follows: off—no radio present RF 2 yellow—radio initializing red—radio failure solid green—radio OK blinking green—radio activity The status LED for Radio 1 is a follows: off—no radio present RF 1 yellow—radio initializing red—radio failure solid green—radio OK blinking green—radio activity Status AP-Controller operational status (see Table 11) Power green—presence of power Table 11: AP200 Controller Status Information State Interpretation AP200 LED Cycle Attempting to discover Controller In the process of discovering the controller. The AP is connected but not associated with the controller. If the AP does not associate with the controller after a period of time, verify that the connection between the AP and the switch or the switch and the controller is unbroken. Green/Red/Blue/R ed Connected Normal operation without security. Blue/Blue/Blue/R ed Blue/Blue/Blue/R ed, for 2 seconds. Authenticated Normal operation with security. Blue blink a © 2008 Meru Networks, Inc. Installing the AP200 43 Checking LED Activity State Interpretation AP200 LED Cycle Disconnected Access point was once connected to a controller and configured by the controller, but can no longer find that controller Green/Purple/ Green/Purple Standalone Access point is operating in a standalone mode Purple blink Downloading Downloading image or configuration from the controller Green/Blue Green/Blue Access point is in an error state. Red (blinking or solid) Error State Call Meru technical support a. The AP200 LEDs cycle from bright to dim for each “blink.” 44 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Chapter 4 Installing the OAP180 This chapter describes how to physically install the OAP180. It contains the following sections: z Safety Precautions z Unpacking the OAP180 z Installation Requirements z Installing the Access Points z Where to Go From Here z Checking LED Activity Safety Precautions IMPORTANT—Read and follow the instructions in Appendix E, “Regulatory Information” on page 115 before installing and operating this product. This product is intended to be supplied by a UL Listed power supply, marked Class 2 or LPS, and rated minimum 5 Vdc, 3A. Caution! The OAP180 is not certified for plenum installations, and should not be installed in the plenum space. © 2008 Meru Networks, Inc. Installing the OAP180 45 Unpacking the OAP180 Unpacking the OAP180 Figure 26: OAP180 Outdoor Access Point Top panel view 2.4G Bottom panel view 5G 5G 2.4G Console PoE N-Type External Antenna Connector (5 GHz) N-Type External Antenna Connector (2.4 GHz) Console Port Ethernet/PoE Connector Water-Tight Test Point 00195 Console Port Cover Attachment Confirm that the OAP180 shipping boxes contain the following items: z OAP180 Outdoor Access Point z Wall/Pole Mount Hardware Kit for mounting OAP180 to a 1.5” to 2” diameter steel pole or tube or as part of a radio or tower structure z N-Type Female connectors for external antennas z Outdoor CAT5 Ethernet cable—100 feet. Be sure to include this (maximum) 100 foot cable in link path calculation; the PoE does not resend the traffic, it only provides power. z Power injector with power cord Installation Requirements In addition to the hardware supplied by Meru Networks, you need the following: Required z Standard Ethernet cable to connect the power injector to a switch or controller z Antennas (sold separately) z Ground wire for the OAP180 Optional z RF coaxial cable to connect the antenna to the OAP180 46 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points Installing the Access Points Selecting a Location When you plan the OAP180 physical configuration, include the elements shown in this drawing: External Antenna Indoor Outdoor RF Coaxial Cable LAN Switch OAP 180 Ethernet Cable Power Injector 00196 Ground Wire AC Power Figure 27: Sample Physical Layout Radio Position Planning Never construct a radio mast, pole, or tower near overhead power lines. In addition, local regulations may limit or prevent construction of a high radio mast or tower. If your OAP180 link requires a high radio mast or tower, consult a professional contractor for advice. Once the required antenna height has been determined, other factors affecting the precise position of the OAP180 must be considered. z Be sure there are no other radio antennas within 2 m (6 ft.) of the OAP180. z Place the OAP180 away from power and telephone lines. z Avoid placing the OAP180 too close to any metallic, reflective surfaces, such as roof- installed air-conditioning equipment, tinted windows, wire fences, or water pipes. Radio Interference Avoiding radio interference is an important part of wireless planning. Interference is caused by other radio transmissions using the same or an adjacent channel frequency. You should first scan your proposed site using a spectrum analyzer to determine if there are © 2008 Meru Networks, Inc. Installing the OAP180 47 Installing the Access Points any strong radio signals using the 802.11a or 802.11bg channel frequencies. Always use a channel frequency that is furthest away from another signal. Weather Conditions Take into account any extreme weather conditions that are known to affect your location. Consider these factors: z Temperature — The OAP180 is tested for normal operation in temperatures from - 40°F to 140°F. Operating in temperatures outside of this range may cause the unit to fail. z Wind Velocity — The OAP180 can operate in winds up to 44 m/s and survive higher wind speeds up to 66 m/s. You must consider the known maximum wind velocity and direction at the site and be sure that any supporting structure, such as a pole, mast, or tower, is built to withstand this force. z Lightning — The OAP180 includes its own built-in lightning surge protection. However, you should make sure that the unit, any supporting structure, and cables are all properly grounded. Additional protection using lightning rods, lightning arrestors, or surge suppressors may also be employed. Antenna sockets should point upwards in a vertical manner z Rain — The OAP180 is weatherproofed against rain. Also, prolonged heavy rain has no significant effect on the radio signal. However, it is recommended to apply weatherproof sealing tape around the Ethernet port and antenna connectors for extra protection. If moisture enters a connector, it may cause a degradation in performance or even a complete failure of the link. z Snow and Ice — Falling snow, like rain, has no significant effect on the radio signal. However, a build up of snow or ice on antennas may cause the link to fail. In this case, the snow or ice has to be cleared from the antennas to restore operation of the link. Ethernet Cabling When a suitable antenna location has been determined, plan a cable route from the OAP180 outdoors to the power injector module indoors. Consider these points: z The Ethernet cable length should never be longer than 100 ft. z Determine a building entry point for the cable. z Determine if conduits, bracing, or other structures are required for safety or protection of the cable. z For lightning protection at the power injector end of the cable, consider using a lightning arrestor immediately before the cable enters the building. z The shield of the ethernet cable needs to be grounded at the lightning arrestor. If, by design, the lightning arrestor cannot provide this ground, the shield of the ethernet cable will need to be grounded by the installer. 48 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points Grounding It is important that the OAP180, cables, and any supporting structures are properly grounded. The OAP180 unit includes a grounding screw to attach a ground wire. Be sure that grounding is available and that it meets local and national electrical codes. Test Basic Link Operation Set up the OAP180 on the ground, either outdoors or indoors. Connect the unit as indicated in this document and perform the basic configuration tasks outlined below. When you are satisfied that the OAP180 is operating correctly, proceed to mounting the unit in the intended location. Mounting the Access Point The OAP180 can be mounted on the following (brackets are included): z 1.5 to 2 inch diameter pole z Wall Mounting OAP180 with the Pole-Mounting Bracket Follow these steps to mount the unit to a 1.5 to 2 inch diameter steel pole or tube using the mounting bracket: 1. Attach the OAP180 to the mounting bracket. Figure 28: Square Mounting Bracket Attaches to Bottom of OAP180 00199 Attach the adjustable rectangular plate to the bridge with supplied screws 2. Place the V-shaped part of the bracket around the pole and tighten the securing nuts just enough to hold the bracket to the pole. (The bracket may need to be rotated around the pole during the alignment process.) © 2008 Meru Networks, Inc. Installing the OAP180 49 Installing the Access Points Note: Always attach the bracket to a pole with the open end of the mounting grooves facing up. Figure 29: Brackets Attached to a Pole 00201 Attach the bridge with bracket to affixed plate on pole 3. Use the included nuts to tightly secure the wireless OAP180 to the bracket. 4. Connect the OAP180 bracket and the pole bracket. Mounting OAP180 with the Wall-Mounting Bracket Attach the bracket to a wall with the flat side flush against the wall. Follow these steps to mount the unit to a wall using the wall-mounting bracket: 1. Position the bracket in the intended location and mark the position of the four mounting screw holes. 02 2. Drill holes in the wall that match the screws and wall plugs included in the bracket kit, and then secure the bracket to the wall. 3. Use the included nuts to tightly secure the OAP180 to the bracket. 4. Connect the two brackets as shown below. 50 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. 00203 Installing the Access Points Connect Antennas and Ground Wire to OAP180 Nine antennas are supported for the OAP180. The supported antennas are: z MN-ACC-ANT-BG08O-NM 802.11 b/g 8 dBi Omni-Directional Antenna, 2400 - 2500GHz (N Male) z MN-ACC-ANT-BG08O-NF 802.11 b/g 8 dBi Omni-Directional Antenna, 2400 - 2500GHz (N Female) z MN-ACC-ANT-BG18P-NF 802.11 b/g 18 dBi High Gain Panel Directional Antenna, 2400 - 2500GHz (N Female) z MN-ACC-ANT-BG10S-NF 802.11 b/g 10 dBi High Gain Sector Antenna, 2400 - 2500GHz (N Female) z MN-ACC-ANT-A08O-NM-1 802.11a 8 dBi Omni-Directional Antenna, 5150 - 5350GHz (N Male) z MN-ACC-ANT-A08O-NM-2 802.11a 8 dBi Omni-Directional Antenna, 5470 - 5875GHz (N Male) z MN-ACC-ANT-A08O-NF 802.11a 8 dBi Omni-Directional Antenna, 4900 - 5350GHz (N Female) z MN-ACC-ANT-A23P-NF 802.11a 23 dBi High Gain Directional Panel, 5150 - 5875GHz (N Female) * z MN-ACC-ANT-A13S-NF 802.11a 13 dBi High Gain 120-degree Sector Antenna, 4900- 5150/5150-5875GHz (N Female) * Not supported for the DFS bands 5.25 - 5.35 GHz and 5.47 - 5.725 GHz The OAP180 works both with antennas that attach to the unit and remote antennas. When using antennas that attach to the unit, attach the antenna before installing the unit. Use the two connectors on the right (5G-1 and 2.4G-1) as indicated in Figure 8. When deploy- © 2008 Meru Networks, Inc. Installing the OAP180 51 Installing the Access Points ing an OAP180 with a remote antenna, first mount remote antennas and then connect them to the OAP180. Follow these steps: 1. Remove the two right-most antenna covers indicated in Figure 8. 2. Mount the external antenna on the same supporting structure as you did the OAP180, within 3 m (10 ft.) of it, using the bracket supplied in the antenna package. 3. Connect the antenna to the OAP180’s N-type connector (5G-1 and 2.4G-1) using the RF coaxial cable provided in the antenna box. Figure 30: Connect the Antenna Cables 5 GHz External High-gain Panel Antenna 5G-2 5G-1 2.4G-1 2.4 GHz N-type 5 GHz N-type Connector (5G-1) Connector (2.4G-1) RF Coaxial Cable 2.4 GHz External Omnidirectional Antenna 00204 2.4G-2 4. Apply weatherproofing tape to the antenna connectors to help prevent water entering the connectors. Note: When not using antenna connectors on the OAP180, keep the covers securely attached for weather protection. Follow these steps to attach the Ethernet cable and ground wire: 1. Using the included cable, attach the Ethernet cable to the Ethernet port on the OAP180. Note: Use only the provided Ethernet cable. Do not shorten this cable as the path loss is needed. During periods of lightning activity, do not connect or disconnect cables or otherwise work with the OAP180. 52 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points Console Port PoE (Ethernet) Port Console PoE Ground Wire 00205 Ethernet Cable 2. For extra protection against rain or moisture, apply weatherproofing tape (not included) around the Ethernet connector. 3. Ground the unit with an appropriate grounding wire (not included) by attaching it to the grounding screw on the unit. See above. Caution! Equipment shall be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part 1, and when applicable, the National Electrical Safety Code, IEEE C2. Equipment shall be properly grounded according to Chapter 8 of ANSI/NFPA 70, the National Electrical Code (NEC) and the Cable distribution system should be grounded (earthed) in accordance with ANSI/NFPA 70, the National Electrical Code (NEC), in particular Section 820.93, Grounding of the Outer Conductive Shield of a Coaxial Cable. The separate protective earthing terminal provided on this product shall be permanently connected to earth. Caution! Do not locate the power injector outdoors. The unit is for indoor use only. Note: The wireless Ethernet port does not support Power over Ethernet (PoE) based on the IEEE 802.3af standard. Do not try to power the unit by connecting it directly to a network switch that provides IEEE 802.3af PoE. Always connect the unit to the included power injector module to maintain the warranty. Note: Each AC power injector requires 1.5 amps of power at 100-240 volts. When connecting multiple devices to one outlet, be sure to allow 1.5 amps for each AC power adapter. © 2008 Meru Networks, Inc. Installing the OAP180 53 Installing the Access Points Follow these steps to connect the power injector: 1. Connect the other end of the provided Ethernet cable (already connected to the OAP180) to the RJ-45 port labeled Output on the power injector. AC power Ethernet cable from LAN switch Ethernet cable to wireless bridge 00206 Power LED indicator 2. Connect a straight-through unshielded twisted-pair (UTP) cable (not included) from a local LAN switch to the RJ-45 port labeled Input on the power injector. See the illustration above. Use Category 5e or better UTP cable for 10/100BASE-TX connections. Note: The RJ-45 port on the power injector is an MDI port. If connecting directly to a computer for testing the link, use a crossover cable. 3. Insert the power cable plug directly into the standard AC receptacle on the power injector. See the illustration above. 4. Plug the other end of the power cable into a grounded, 3-pin socket, AC power source. Note: For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the receptacle type in your country. 5. Check the LED on top of the power injector to be sure that power is being supplied to the OAP180 through the Ethernet connection. Align Antenna After the OAP180 unit is mounted, connected, and the radios are operating, the antennas must be accurately aligned to ensure optimum performance of the OAP180 links. In 54 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Where to Go From Here this point-to-multipoint configuration all OAP180 nodes must be aligned with the root OAP180 antenna. Where to Go From Here Now that the OAP180 is installed, go to the Meru System Director Getting Started Guide for instructions on initializing the controller and connecting the controller and APs to the Ethernet switch to form the WLAN. Return to this chapter to check the status of the LEDs once the WLAN is operational. As well, check the AP chapter in the Meru System Director Configuration Guide for instructions on configuring radio band, dual radio, and external antenna operation. Checking LED Activity Check the OAP180 LEDs for activity. Four of the eight LEDs on the bottom of the OAP180 indicate activity; four LEDs are not used at this time. Check the four active LEDs to determine if the AP is working. Console PoE Power On LED Ethernet link LED Transmission LEDs (radio packets transmitting) © 2008 Meru Networks, Inc. 00194 These 4 LEDs are not used Installing the OAP180 55 Checking LED Activity Figure 31: OAP180 LEDs The grey LEDs in the illustration are not currently used. The following chart explains the meanings for the remaining LEDs. LED Function Power When power is applied, this LED initially turns amber, then blinks green when the system power check is applied, and then is a steady green when power is on. Radio 1 802.11bg Radio 2 802.11a Ethernet The 11bg connection LED blinks amber when radio packets are being transmitted and when the radio is beaconing. If there is traffic over the air on this radio, the blinking rate increases. The 11a connection LED blinks green when radio packets are being transmitted and when the radio is beaconing. If there is traffic over the air on this radio, the blinking rate increases. The Ethernet Link LED blinks green when a link has been detected and is in use. Antenna Gain Recommendations The OAP180 auto-adjusts the power level sent from the radio to the antenna, so that the EIRP emitted from the antenna is the value defined by the controller (100mW by default). You can increase this setting if you are compensating for signal loss from long inexpensive cables connecting external antennas. (Configure a false/low dBi antenna gain to trick the radio into supplying more transmit power to that antenna, which would then make up for the cable loss.) You may also need to decrease the EIRP from 100mW to 30mW for a device that only transmits at 30mW. The Antenna Gain values can be changed from the Web UI Configuration>APs>Antenna Properties view, or from the CLI using the antennaproperty command. Determine the appropriate gain for your antenna by checking the following chart. 56 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Checking LED Activity Table 12: Antenna Gain Antenna MN-ACC-ANT-BG08O-NM 802.11 b/g 8 dBi OmniDirectional Antenna, 2400 - 2500GHz (N Male) Gain MN-ACC-ANT-BG08O-NF 802.11 b/g 8 dBi OmniDirectional Antenna, 2400 - 2500GHz (N Female) MN-ACC-ANT-BG18P-NF 802.11 b/g 18 dBi High Gain Panel Directional Antenna, 2400 - 2500GHz (N Female) 18 MN-ACC-ANT-BG10S-NF 802.11 b/g 10 dBi High Gain Sector Antenna, 2400 - 2500GHz (N Female) 10 MN-ACC-ANT-A08O-NM-1 802.11a 8 dBi OmniDirectional Antenna, 5150 - 5350GHz (N Male) MN-ACC-ANT-A08O-NM-2 802.11a 8 dBi OmniDirectional Antenna, 5470 - 5875GHz (N Male) MN-ACC-ANT-A08O-NF 802.11a 8 dBi OmniDirectional Antenna, 4900 - 5350GHz (N Female) MN-ACC-ANT-A23P-NF 802.11a 23 dBi High Gain Directional Panel, 5150 - 5875GHz (N Female) 23 MN-ACC-ANT-A13S-NF 802.11a 13 dBi High Gain 120-degree Sector Antenna, 4900-5150/51505875GHz (N Female) © 2008 Meru Networks, Inc. 12.5/13.5 Installing the OAP180 57 Checking LED Activity 58 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Chapter 5 Installing the AP150 This chapter describes how to physically install the AP150. It contains the following sections: z Safety Precautions z Unpacking the AP150 z Installation Requirements z Installing the Access Points z Where to Go From Here z Checking LED Activity Safety Precautions IMPORTANT—Read and follow the instructions in Appendix E, “Regulatory Information” on page 115 before installing and operating this product. This product is intended to be supplied by a UL Listed power supply, marked Class 2 or LPS, and rated minimum 5 Vdc, 3A. Caution! The AP150 is not certified for plenum installations, and should not be installed in the plenum space. Unpacking the AP150 Confirm that the AP150 shipping package contains the AP150 access point with attached mounting bracket © 2008 Meru Networks, Inc. Installing the AP150 59 00177 Installation Requirements Figure 32: AP150 with Mounting Bracket Installation Requirements If you choose not to use the AP150 mounting bracket, the backside of the AP150 contains two keyholes to accommodate a simple wall mount. A mounting bracket can be used for many wall mounting configurations. The AP150 bracket mounting studs are placed so they can be used with brackets supplied by other vendors or to replace an AP100. An array of holes on the mounting bracket (see Figure 32) allow it to be mounted on the wall and over junction boxes or molly bolts. There are also holes for passing the PoE Ethernet or external power supply cable through the bracket if the bracket is mounted on a junction box. Additional optional mounting kits are available for mounting the AP150below a hanging ceiling, using the mounting bracket. 60 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installation Requirements Caution! The AP150 is not certified for plenum installations, and should not be installed in the plenum space. Note: The AP150 has two security cable slots (one on each side of the AP150) so you can secure the AP150 with a standard security cable, such as those used to secure laptop computers. The following recommended mounting locations provide the best reception for the AP150: z On a horizontal surface, such as a table or a desk z On a vertical surface, usually a wall z Below a hanging ceiling To complete this installation, you need the items listed in Table 13. Table 13: AP150 Installation Items Installation Type Consumable Items Required Horizontal mounting None Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling © 2008 Meru Networks, Inc. Two #6 x 2" wood screws for a wood stud; or Two #6 x 1½" metal screws for a metal stud Mounting bracket Two #6 x 1" screws Two #4-6 x 7/8" ribbed plastic wall anchors Mounting bracket Two caddy fasteners Two plastic spacers Two keps nuts (with attached lock washer) Mounting bracket Installing the AP150 61 Installing the Access Points You need the tools listed in Table 14. Table 14: AP150 Installation Tools Installation Type Tools Required Horizontal mounting None Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling Drill 1/8"drill bit Screwdriver 1/8"Allen wrench Drill 3/16" drill bit Screwdriver 1/8"Allen wrench Screwdriver Wrench or pliers 1/8"Allen wrench Installing the Access Points Selecting a Location The AP150 requires a location that meets the following: z Relatively unobstructed access to the stations the AP serves z Power over Ethernet (PoE) connection to the network switch servicing the controller. APs can obtain their power from 802.3af standard Power over Ethernet (PoE)-compatible network switch or PoE power injector installed between the switch and the AP150. Select a location with minimal physical obstructions between the AP and the wireless stations. In an office with cubicles, mounting the APs below a hanging ceiling or the wall near the ceiling provides the least obstructed communications path. 62 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points Most installations receive the best coverage using the following guidelines: Install APs toward the center of the building. z Do not install APs near metal objects, such as heating ducts, metal doors, or electric service panels. z Relative to the ground, orient the antenna up or down, not sideways. Note: The previous guidelines are general guidelines. Each site has its own unique environment. Place access points accordingly. The AP150 is only intended for installation in Environment A as defined in IEEE 802.3af. All interconnected equipment must be contained within the same building, including the interconnected equipment's associated LAN connection. Attaching the AP150 Antennas The AP150 is provided with external antenna ports. Make sure that all external antennas and their associated wiring are located entirely indoors. The external antennas are not suitable for outside use. If the AP150 does not have external antennas, attach the antennas to the connectors on the AP150 (see Figure 33). Rotate the knurled ring at the base of the antenna clockwise to attach the antenna. The ring should be finger-tight. Caution! When changing the orientation of the antennas, be sure to slightly loosen the knurled ring before moving the antenna. Retighten the ring afterward. Otherwise, you might damage the internal cabling in the AP. Mounting the Access Point You can mount an AP150 in the following ways: z Horizontally, as described in the “Horizontal Mounting” section. z Vertically, as described in the “Vertical Mounting with the Mounting Bracket” section. z Below a hanging ceiling, as described in the “Mounting Below a Suspended Ceiling” section. Horizontal Mounting To horizontally mount an AP150: 1. Place the AP150 flat on the horizontal surface. 2. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 33), point the antenna straight up, then retighten the ring. © 2008 Meru Networks, Inc. Installing the AP150 63 Installing the Access Points RES ET REL OAD ANT 2 00172 Antenna Turn clockwise to tighten Figure 33: AP150 Antenna Connection 3. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 34. Antenna 1 Power Ethernet (reserved) connection Console port Reset Reload (reserved) button ANT1 Antenna 2 ANT2 LAN CONSOLE RESET RELOAD 00173 DC 5V Figure 34: AP150 Connector Panel Vertical Mounting the AP150 To perform a simple wall mount using the keyholes on the back of the AP150: 1. Remove the attached mounting bracket from the back of the AP150. 2. Mark the location on the wall for two mounting screws. They are placed 4.3" apart, center-to-center, or one above the other. If you are not using plastic wall anchors, you must either center the mounting screws on a wall stud or use plastic wall anchors. 3. Drill holes at the locations you marked: — 3/16-inch holes if you are using plastic anchors — 1/8-inch holes if you are using only the screws 64 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the Access Points 4. If you are using plastic anchors, install them in the holes. 5. Screw in the screws most of the way, so that the screw head is about 1/16 of an inch from the wall. 6. Align the AP150 keyholes over the mounting screws and slightly pull down (or across, if mounting sideways). 7. For external antennas, loosen the knurled ring at the base of each antenna (see Figure 33), point the antenna straight up, then retighten the ring. 8. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 34. Vertical Mounting with the Mounting Bracket The AP150 uses thumbscrews to attach to the mounting bracket or mounting plate that allows the access point to be mounted on a vertical surface. Additionally, three shoulder screws may be installed on the mounting bracket to allow the AP150 and attached bracket to mount over a previously installed Cisco 1200 mounting bracket. To vertically mount an AP: 1. If not mounting the AP150 to a previously third-party installed mounting bracket, use a 1/8" Allen wrench to remove the shoulder screws from the mounting bracket, if already attached. 2. Using the bracket holes as a template, remove the bracket from the AP150 (or use the stencil in Appendix C, “Mounting Bracket Stencils”) to mark the location on the wall for the two AP bracket mounting screws. They are placed 4.3 inches apart, center-to-center. If you are not using plastic wall anchors, you must center the mounting screws on a wall stud. If you do not center the mounting screws on a wall stud, you must use plastic wall anchors. © 2008 Meru Networks, Inc. Installing the AP150 65 00167 Installing the Access Points Suspended ceiling cable access Wall cable access Figure 35: AP150 Bracket 3. Drill holes at the locations you marked: — 3/16-inch holes if you are using plastic anchors — 1/8-inch holes if you are using only the screws 4. If you are using plastic anchors, install them in the holes. 5. Screw in the screws most of the way, so that the screw head is about 1/16 of an inch from the wall. 6. Mount the bracket on the screws, placing the circular portion of the keyhole mounts over the screw heads and sliding the bracket down. 7. Tighten the screws to secure the bracket. 8. Align the AP150 with the bracket thumbscrews (see Figure 36) and tighten the thumbscrews to attach the bracket. 66 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. 00169 Installing the Access Points Figure 36: Aligning the AP150 with the Bracket 9. For external antennas, loosen the knurled ring at the base of each antenna (see Figure 33), point the antenna straight up, then retighten the ring. 10. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in Figure 34. © 2008 Meru Networks, Inc. Installing the AP150 67 Installing the Access Points Mounting Below a Suspended Ceiling The optional suspended ceiling mounting kit allows the AP150 mounting bracket to attach to suspended ceiling T-rails (see Figure 37). Note: To comply with NEC code, attach a grounding wire to any of the screws used to attach the AP150 to the mounting bracket. Suspended ceiling T-rail Caddy fastener(s) Spacer(s) 00170 Mounting bracket Washers Figure 37: Mounting the AP150 to a Suspended Ceiling Rail To mount an AP150 below a suspended ceiling: 1. Using a 1/8" Allen wrench, remove the shoulder screws from the mounting bracket, if already attached. 2. Determine the location on the ceiling rail where the AP will be mounted and remove the ceiling tiles. 3. Place each of the two caddy fasteners on the ceiling T-rail and twist to attach to the rail. 4. Adjust the distance between the caddy fasteners by using the mounting bracket holes as a guide. 5. Tighten the caddy fasteners in place using a standard screwdriver. Do not overtighten. 6. Place each spacer on the caddy fastener stud. The spacer legs should contact the ceiling T-rail. 7. Align the mounting bracket keyholes with the caddy fastener studs and slide the AP150 to the narrow end of the hole. 68 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Where to Go From Here 8. Attach a keps nut to each caddy fastener stud and hand tighten. Do not overtighten. 9. Align the AP150 with the bracket thumbscrews (see Figure 36) and tighten the thumbscrews to attach the bracket. 10. For each antenna, loosen the knurled ring at the base of the antenna (see Figure 33), point the antenna straight down, then retighten the ring. 11. Connect one end of the PoE 100BaseT Ethernet cable to the 100/1000 Ethernet connector, shown in (see Figure 34). Where to Go From Here Now that the AP150 is installed, go to the Meru System Director Getting Started Guide for instructions on initializing the controller and connecting the controller and APs to the Ethernet switch to form the WLAN. Return to this chapter to check the status of the LEDs once the WLAN is operational. © 2008 Meru Networks, Inc. Installing the AP150 69 Checking LED Activity Checking LED Activity Access point status LEDs are provided on the Ethernet connector and on the face of the AP150. AP150 Status LEDs Four status LEDs on the face of the AP150 also light, as shown in Figure 38. RAD IO 1 RAD IO 2 PW 00166 LA N Status LEDs Figure 38: AP150 Status LEDs When the AP150 is first connected to the controller and any time the access point is rebooted thereafter, the AP initializes with and then is programmed by the controller. The Status LED (see Figure 38) color reflects the various operating states (Table 15). 70 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Checking LED Activity Table 15: AP150 LED Descriptions LED Function The Power status LED status is as follows: off—power is off solid red—when power is applied, system initializes for 40 seconds and then the LED turns amber; after discovering the controller the LED turns green. Otherwise, the system is in an abnormal state (notify Customer Support). solid amber—at any time, if this LED state persists longer than 40 seconds, notify Customer Support solid green—system is fully operational Power Radio I The Radio I LED is lit when radio packets are being transmitted and when the radio is beaconing. Radio II The Radio II LED is lit when radio packets are being transmitted and when the radio is beaconing. The Ethernet LED status is as follows: Ethernet © 2008 Meru Networks, Inc. off—no link solid green—100Mbps connection blinking green—transmit or receive activity at 100Mbps solid amber—10Mbps connection blinking amber—transmit or receive activity at 10Mbps Installing the AP150 71 Checking LED Activity 72 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Chapter 6 Installing the RS4000 This chapter describes how to physically install the Meru Radio Switch RS4000. It contains the following sections: z Safety Precautions z Unpacking the RS4000 z Installation Requirements z Installing the RS4000 z Where to Go From Here z Checking LED Activity Safety Precautions IMPORTANT—Read and follow the instructions in Appendix E, “Regulatory Information” on page 115 before installing and operating this product. Unpacking the RS4000 Confirm that the RS4000 shipping package contains the following items: z RS4000 z 180-degree directional antenna or omni-directional antenna z Two 3-foot antenna cables z One 3-inch mounting arm (includes wall mount base and ceiling rail base) z Mounting bracket z Additional options can be purchased, such as a NEMA box mounting bracket and 6-foot antenna cables © 2008 Meru Networks, Inc. Installing the RS4000 73 Installation Requirements POWE RADIO II RADIO ET ETHERN Antenna RS4000 Wall mounting bracket 3-inch mounting arm with wall mounting base 00193 Ceiling rail mounting base Figure 39: RS4000 Package Contents Installation Requirements The following prerequisites and system requirements must be met: z 2 IEEE 802.3 PoE connections— one to each Ethernet port, yielding a maximum power specification of 11W per port, 22W total for the RS4000 z Network switch for connecting all networking components The RS4000 requires a location that meets the following: z A location to mount the antenna within 6’ of the RS4000 and with relatively unobstructed access to the client stations z Power over Ethernet (PoE) connection to the network switch servicing the RS4000 74 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installation Requirements The RS4000 obtains power from 802.3af standard Power over Ethernet (PoE)-compatible network switch or PoE power injector installed between the switch and the RS4000. At least one PoE connection must be connected. Select a location with minimal physical obstructions between the RS4000 antenna and the wireless stations. In many cases, mounting the RS4000 antenna on the wall near the ceiling provides the least obstructed communications path. Most installations receive the best coverage using the following guidelines: z Do not install the antenna near metal objects, such as heating ducts, metal doors, or electric service panels. z Relative to the ground, orient the antenna up or down, not sideways. Note: The previous guidelines are general guidelines. Each site has its own unique environment. Place antenna accordingly. The RS4000 is only intended for installation in Environment A as defined in IEEE 802.3af. All interconnected equipment must be contained within the same building, including the interconnected equipment's associated LAN connection. © 2008 Meru Networks, Inc. Installing the RS4000 75 Installation Requirements You need the tools listed in Table 16. Table 16: RS4000 Installation Tools Installation Type Vertical mounting over a wall stud Vertical mounting on sheetrock Horizontal mounting below a hanging ceiling Mounting above a ceiling tile Tools Required Drill 1/8"drill bit Screwdriver (Optional) Pliers Drill 3/16" drill bit Screwdriver (Optional) Pliers Two caddy fasteners Two plastic spacers Two keps nuts (with attached lock washer) Mounting bracket Two T-rail clips One T-box hanger One bracket mounting clip Mounting bracket About an Hoffman/NEMA Enclosure Installation The recommended RS4000 installation is a wall mount, but if necessary the RS4000 can be housed inside a protective NEMA or Hoffman box that is manufactured with external corner tabs for standard wall mounting, above or below a ceiling. When installing in the Hoffman/NEMA box, the RS4000 attaches to an optional Hoffman/NEMA box mounting plate, which replaces the standard wall mount bracket. Caution! This method of mounting has not been evaluated by Underwriters Laboratories. Meru leaves the placement and orientation of the Hoffman/NEMA enclosure to the customer. It will be necessary to drill holes through the plastic NEMA enclosure with a Meru-provided template to enable the antenna and Ethernet cabling to exit the enclosure. Instructions for performing this task are provided in the section “Creating 76 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installation Requirements Cable Pass-through Holes in the NEMA Enclosure” on page 89. To install in the Hoffman/NEMA Enclosure, see the section “Hoffman/NEMA Enclosure RS4000 Installation” on page 89. NEMA box 00187 Attach to wall with 4 screws Figure 40: Open NEMA Box Showing Mounting Holes Optimum Antenna Positioning and Placement Warning! Inside antennas must be positioned to observe minimum separation of 20 cm. (~ 8 in.) from all users and bystanders. For the protection of personnel working in the vicinity of inside (downlink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed. The installation of the indoor antenna must be such that, under normal conditions, all personnel cannot come within 20 cm. (~ 8.0 in.) from any inside antenna. Exceeding this minimum separation will ensure that the employee or bystander does not receive RF-exposure beyond the Maximum Permissible Exposure according to FCC CFR 47, section 1.1310 i.e. limits for General Population/Uncontrolled Exposure. © 2008 Meru Networks, Inc. Installing the RS4000 77 Installing the RS4000 Installing the RS4000 Mounting the RS4000 You can mount the RS400 in the following ways: z Wall Mounting the RS4000 z Mounting Below a Suspended Ceiling z Mounting Above a Suspended Ceiling z Placing and Positioning the Antenna z Hoffman/NEMA Enclosure RS4000 Installation Wall Mounting the RS4000 The RS4000 can be mounted to any type of solid wall (including ceiling walls) using the supplied wall mount bracket. The bracket also allows for junction box mounting. Note: The RS4000 has a security cable slot so you can secure the RS4000 with a standard security cable (for example, Kensington cable locks), such as are used to secure laptop computers. To wall mount an RS4000: 1. Remove the bracket from back side the RS4000, if it is attached, by unscrewing each of the 4 knurled thumbscrews (see Figure 41). 78 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 Figure 41: Bracket Attached to RS4000 2. Choose the location on the wall where the RS4000 will be mounted. The RS4000 can be oriented in any direction, but it is probably more convenient if the SMA antenna mounts are at the top. This orientation is more convenient for reading LED status. 3. Using the bracket holes as a template, mark the location on the wall for the two RS4000 bracket mounting screws. They are placed 5 25/32" (147mm) apart, center-to-center, one above the other. If you are not using plastic wall anchors, you must center the mounting screws on a wall stud. Note: The RS4000 mounting bracket provides holes to accommodate many types of common installations such as over a junction box, etc. This procedure describes only the standard wall mount. 4. Drill holes at the locations you marked: — 3/16-inch holes if you are using plastic anchors — 1/8-inch holes if you are using only the screws 5. If you are using plastic anchors, install them in the holes. © 2008 Meru Networks, Inc. Installing the RS4000 79 Installing the RS4000 6. Screw in the screws most of the way, so that the screw head is about 1/16 of an inch from the wall. 7. Mount the bracket on the screws, placing the circular portion of the keyhole mounts over the screw heads and sliding the bracket down. Wall mounting bracket (attached to wall) Captive screws (4) RS4000 POWE RADIO II RADIO ET 00186 ETHERN Figure 42: RS4000 Bracket Mounting 8. Tighten the bracket captive screws to secure the RS4000 to the bracket. 9. On the RS4000, attach the two antenna cables to the SMA antenna connectors labeled ANT1 and ANT2 on the top panel of the RS4000 (see Figure 43) by turning the cable ends clockwise until tight. 80 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 ANT1 ANT2 ETH1 ETH2 00182 (Meru logo is upside down) ANT2 ANT1 Figure 43: RS4000 with Antenna Attached 10. Attach at least one Ethernet cable to the Ethernet port labeled ETH1 and optionally to ETH2 on the top panel of the RS4000. If just ETH1 is connected, only two of the four radios will be active. 11. Align the RS4000 to the bracket (against the wall) and tighten the four knurled thumbscrews until secure. If necessary, apply extra tightening with pliers. 12. Attach the antenna cables to the antenna, as described in “Placing and Positioning the Antenna.” 13. Connect the two Ethernet cables to the PoE device. 14. Apply power to the PoE component and network switch to power up the RS4000. 15. Verify correct operating using the LEDs, as shown in “Checking LED Activity.” © 2008 Meru Networks, Inc. Installing the RS4000 81 Installing the RS4000 Mounting Below a Suspended Ceiling The optional suspended ceiling mounting kit allows the RS4000 mounting bracket to attach to suspended ceiling T-rails (see Figure 44). Note: To comply with NEC code, attach a grounding wire to any of the screws used to attach the RS4000 to the mounting bracket. Ceiling tile fastener 00189 Mounting bracket Washers Figure 44: Mounting the RS4000 Below a Suspended Ceiling Rail To mount an RS4000 below a suspended ceiling: 1. Determine the location on the ceiling rail where the RS4000 will be mounted and remove the ceiling tiles. 2. Place each of the two caddy fasteners on the ceiling T-rail and twist to attach to the rail. 3. Adjust the distance between the caddy fasteners by using the mounting bracket holes as a guide. 4. Tighten the caddy fasteners in place using a standard screwdriver. Do not overtighten. 5. Place each spacer on the caddy fastener stud. The spacer legs should contact the ceiling T-rail. 6. Align the mounting bracket keyholes with the caddy fastener studs and slide the RS4000 to the narrow end of the hole. 82 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 7. Attach a keps nut to each caddy fastener stud and hand tighten. Do not overtighten. 8. On the RS4000, attach the two antenna cables to the SMA antenna connectors labeled ANT1 and ANT2 on the top panel of the RS4000 (see Figure 43) by turning the cable ends clockwise until tight. ANT1 ANT2 ETH1 ETH2 00182 (Meru logo is upside down) ANT2 ANT1 Figure 45: RS4000 with Antenna Attached 9. Attach at least one Ethernet cable to the Ethernet port labeled ETH1 and optionally to ETH2 on the top panel of the RS4000. If just ETH1 is connected, only two of the four radios will be active. 10. Align the RS4000 to the bracket and tighten the four knurled thumbscrews until secure. If necessary, apply extra tightening with pliers. 11. Attach the antenna cables to the antenna, as described in “Placing and Positioning the Antenna.” 12. Connect the two Ethernet cables to the PoE device. 13. Apply power to the PoE component and network switch to power up the RS4000. 14. Verify correct operating using the LEDs, as shown in “Checking LED Activity.” © 2008 Meru Networks, Inc. Installing the RS4000 83 Installing the RS4000 Mounting Above a Suspended Ceiling The optional T-bar box hanger mounting kit allows the RS4000 to be mounted above suspended ceiling T-rails (see Figure 46). The installation attaches the T-bar box hanger to the ceiling rails using clips. The RS4000 attaches to the mounting bracket that is attached to the T-bar box hanger. Note: The RS4000 and its antenna meet the requirements for fire resistance and low smoke-generating characteristics required by Section 300-22(C) of the National Electrical Code (NEC) for installation in a building’s environmental air space. Additonally, you must use Ethernet cable that meets the requirements for operating in environmental air space (in accordance with Section 300-22(C) of the NEC). Any Fast Ethernet (FE) cables installed in air-handling spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum). T-bar hanger Height adjustment screw Mounting bracket Bracket mounting clip Height adjustment screw T-rail clip T-rail clip 00190 RS4000 Suspended ceiling T-rail Figure 46: Mounting the RS4000 Above a Suspended Ceiling To mount an RS4000 above suspended ceiling rails: 1. Determine the location on the ceiling rails where the RS4000 will be mounted and remove the ceiling tile. 84 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 2. Unpack the T-bar hanger kit and unfold the legs of the T-bar hanger. 3. Locate the bracket mounting clip holes on the mounting bracket (see Figure 47). One hole attaches the bracket perpendicular to the box hanger. The other mounts the bracket parallel to the box hanger. 00191 Mounting bracket holes Figure 47: Box Hanger Mounting Bracket Holes 4. Attach the U-joint of the clip to the T-bar and snap in place (see Figure 48). 00192 Figure 48: Attaching the Mounting Bracket to the Box Hanger © 2008 Meru Networks, Inc. Installing the RS4000 85 Installing the RS4000 5. Pass the long end clip through the large center hole to the underside of the the mounting bracket clip and then attach the bracket to the clip using the supplied screw (see Figure 48 for orientation). 6. Hold the RS4000 next to the mounting bracket to estimate the height of the T-bar box hanger to provide enough clearance between the RS4000 and the ceiling. 7. Adjust the height of the box hanger using the height adjusting screws (see Figure 48). 8. Clip the box hanger T-rail clips to the ceiling rails, making sure they are securely attached. 9. Connect a drop wire to a building structural element and through the hole provided in the bracket mounting clip. The U.S. National Electrical Safety Code requires this additional support. 10. Align the RS4000 to the bracket and tighten the four knurled thumbscrews until secure. If necessary, apply extra tightening with pliers. 11. On the RS4000, attach the two antenna cables to the SMA antenna connectors labeled ANT1 and ANT2 on the top panel of the RS4000 (see Figure 43) by turning the cable ends clockwise until tight. ANT1 ANT2 ETH1 ETH2 00182 (Meru logo is upside down) ANT2 ANT1 Figure 49: RS4000 with Antenna Attached 12. Attach at least one Ethernet cable to the Ethernet port labeled ETH1 and optionally to ETH2 on the top panel of the RS4000. If just ETH1 is connected, only two of the four radios will be active. 13. Attach the antenna cables to the antenna, as described in “Placing and Positioning the Antenna.” The antenna can also be mounted within the plenum space if need be. 14. Connect the Ethernet cables to the PoE device. 15. Apply power to the PoE component and network switch to power up the RS4000. 86 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 16. Check that the RS4000 is operating correctly before replacing the ceiling tile to the ceiling. Verify correct operating using the LEDs, as shown in “Checking LED Activity.” Placing and Positioning the Antenna The RS4000 antenna should be mounted to the wall using the 3" mounting arm within 3' of the RS4000 when using the supplied 3-foot cables or 6' when using the optional 6-foot cables. 00179 Direction of Signal Coverage ANT2 ANT1 Figure 50: RS4000 180o Directional Antenna The antenna mount arm includes two screw-in base types to accommodate either wall mounts (Figure 51) or ceiling tile rail mounts (Figure 52). © 2008 Meru Networks, Inc. Installing the RS4000 87 Installing the RS4000 Angle adjusting lever Antenna attachment stud (threaded) 00180 Wall bracket base 00183 Figure 51: Antenna Mounting Arm with Wall Bracket (shown attached) Figure 52: Antenna Ceiling Tile Rail Base The RS4000 antenna uses two RF cables (3-foot cables are supplied) to connect to the SMA connectors on the top panel of the RS4000 (see Figure 43). The RF cables should be attached to the RS4000 as a result of the procedures described in one of the previous installation procedures. Mount the antenna and connect the cables as described in the following: 1. Choose whether to hang the arm on a wall (including solid ceiling wall) or ceiling tile rail. — For wall or ceiling mount: a. Using the screwholes in the mounting bracket as a template, mark and drill holes into the wall. b. Attach the bracket securely with three 1/4" diameter fasteners or one 5/16" diameter and one 1/4" diameter fastener, if mounting to a wall stud (fasteners are not supplied). — For ceiling tile rail mount: a. Pull apart the rail clamps so the ears can fit over the width of the ceiling rail. b. Squeeze the rail clamp to attach to the ceiling rail. 88 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Installing the RS4000 c. Attach the rail mount base to the antenna arm by screwing the base into the arm pole (you may have to unscrew and remove the wall mount base if it is attached to the arm). 2. Connect the RF antenna wires from the RS4000 to the SMA connectors on the top of the antenna, using Figure 43 or Figure 50 for orientation. 3. Attach the top of the antenna to the 1/4-20 threaded stud on the swivel head and tighten against the antenna. 4. For a 180 o directional antenna, position the antenna such that the logo on the top of the antenna is pointing in the direction where reception is required. 5. Loosen the angle adjusting lever on the swivel assembly, if necessary, to adjust the hanging angle. 6. Position the antenna to maximize the reception and tighten the adjusting lever. Hoffman/NEMA Enclosure RS4000 Installation Use the procedures in this section to mount the RS4000 within the Hoffman or NEMA enclosure. It will be necessary to modify the NEMA enclosure by drilling cable passthrough holes before installing the RS4000. Note: The recommended Meru installation is a vertical wall mount, which allows for unimpeded air flow through the unit. The option to install the RS4000 within a Hoffman/NEMA enclosure is left to the customer’s discretion, based on site-specific factors such as protection and accessibility, etc. Installation in the Hoffman enclosure requires drilling air vents and cable pass-through holes. Creating Cable Pass-through Holes in the NEMA Enclosure To create cable pass-through holes in the NEMA enclosure, Meru supplies a template with markings that coincide with the placement of the Ethernet and antenna cable locations on the RS4000. Depending on the orientation of the RS4000 installation in the NEMA enclosure, the template is to be used on the side of the enclosure adjacent to the RS4000 top panel, where the cables connect. 1. Open the lid of the empty NEMA enclosure to provide unimpeded access to the enclosure sides. 2. On the outside of the empty NEMA enclosure, locate the top center of the side where the cables will exit. 3. Using the pattern on the supplied template, mark the center of the holes and drill a 1/2" to 1" hole at each of the three locations specified by the template. © 2008 Meru Networks, Inc. Installing the RS4000 89 Installing the RS4000 Mounting the RS4000 in the Hoffman/NEMA Enclosure Caution! This method of mounting has not been evaluated by Underwriters Laboratories. To mount the RS4000 in the Hoffman/NEMA enclosure, it is necessary to use the optional mounting plate that is not supplied with the RS4000 packing items. This procedure assumes the Hoffman/NEMA enclosure is already mounted at the site. 1. Remove the wall bracket from back of the RS4000, if attached, by unscrewing each of the 4 knurled thumbscrews. 2. Attach the Hoffman/NEMA mounting plate to the back of the RS4000. 3. Attach the right-angle elbow joint to the antenna cable, if not already attached. 4. Attach the two antenna cables to the SMA antenna connectors labeled ANT1 and ANT2 on the top panel of the RS4000 (see Figure 43) by turning the cable ends clockwise until tight. 5. Attach two Ethernet cables to the Ethernet ports labeled ETH1 and ETH2 on the top panel of the RS4000. 6. Place the RS4000 into the Hoffman/NEMA enclosure, and align the plate screwholes with the holes in the Hoffman/NEMA enclosure. 7. Pass the Ethernet and antenna cables out of the Hoffman/NEMA enclosure through the cable pass-through holes. 8. Tighten the captive screws on the mounting plate to the Hoffman/NEMA enclosure. 9. Attach the antenna cables to the antenna (see Figure 50). 10. Position and align the bottom of the antenna over the threaded stud on the antenna mount arm and tighten the threaded stud to the antenna. Antenna RS4000 00188 NEMA box Figure 53: RS4000 and Antenna Installed in NEMA Enclosure 90 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Where to Go From Here 11. Connect the two Ethernet cables to the PoE device. 12. Apply power to the PoE component and network switch to power up the RS4000. 13. Test the reception for the antenna and then securely tighten the antenna. 14. Verify correct operating using the LEDs, as shown in “Checking LED Activity.” 15. Close the lid to the Hoffman/NEMA enclosure. Where to Go From Here Now that the RS4000 is installed, go to the Meru System Director Getting Started Guide for instructions on initializing the controller and connecting the controller and RS4000 to the Ethernet switch to form the WLAN. Return to this chapter to check the status of the LEDs once the WLAN is operational. © 2008 Meru Networks, Inc. Installing the RS4000 91 Checking LED Activity Checking LED Activity Radio switch status LEDs are provided on the face of the RS4000. RS4000 Status LEDs Status LEDs on the face of the RS4000 light, as shown in Figure 54. .. Status LEDs POWER RADIO I POWER RADIO II RADIO I RADIO II ETHERNET 00185 ETHERNET Figure 54: RS4000 Status LEDs The RS4000 uses 4 LEDs. The functions of the status LEDs are described in Table 17. 92 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Checking LED Activity Table 17: RS4000 LED Descriptions LED Function The Power status LED status is as follows: off—power is off solid red—when power is applied, system initializes for 40 seconds and then the LED turns amber; after discovering the controller the LED turns green. Otherwise, the system is in an abnormal state (notify Customer Support). solid amber—at any time, if this LED state persists longer than 40 seconds, notify Customer Support solid green—system is fully operational Power Radio I The Radio I LED is lit when radio packets are being transmitted and when the radio is beaconing. Radio II The Radio II LED is lit when radio packets are being transmitted and when the radio is beaconing. The Ethernet LED status is as follows: Ethernet © 2008 Meru Networks, Inc. off—no link solid green—100Mbps connection blinking green—transmit or receive activity at 100Mbps solid amber—10Mbps connection blinking amber—transmit or receive activity at 10Mbps Installing the RS4000 93 Checking LED Activity 94 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Appendix A Specifications This chapter provides specifications for Meru Access Points and contains the following sections: z Wireless Interface z Ethernet Interface z Physical the Meru Networks website at http://www.merunetworks.com/products/access_points.php. To see the latest Meru product specifications, check Wireless Interface Table 18: Wireless Interface Specifications Feature Details Wireless Standards 802.11a, 802.11b, 802.11g, 802.11n Antennas Two to six external antennas. Omnidirectional and directional antennas for specific coverage requirements Wireless Medium Access Wi-Fi Compliant 802.11 MAC standard Power Management Power-save mode for clients in both QoS mode and nonQoS mode © 2008 Meru Networks, Inc. Specifications 95 Internal Use Only—Beta Draft Wireless Interface Feature Frame Size Client Activities Supported 96 Details Peak frame size of > 2346 bytes Fragmentation and reassembly of 802.11/Ethernet frames Active scanning and passive scanning Pre-authentication Power-save mode supported Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Ethernet Interface Ethernet Interface Feature Wireline Standard Detail One Ethernet (IEEE 802.3) interface, supporting half-duplex and full-duplex modes Supports the Power over Ethernet (PoE) IEEE 802.3af standard Physical Physical specifications for Meru Access Points are provided in the access point Data Sheet. Contact your Meru sales engineer for a copy of the document. © 2008 Meru Networks, Inc. Specifications 97 Internal Use Only—Beta Draft Physical 98 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Appendix B AP Accessories AP300 Accessories This section provides specifications for the following AP300 Accessories: z AP300 PoE Devices z AP300 Power Supply z AP300 Antennas z AP300 Mounting Options AP300 PoE Devices PoE Description ACC-POE-AT-1AC Mid-Span High Power pre-802.3at PoE injector (1 Port, 110V/220V AC input). Ideal for Meru AP300; backward compatible with 802.3af, also works with Meru AP200 and Meru AP150. Includes US power cords. ACC-POE-AT-12AC Mid-Span 802.3af+ High Power PoE injector (12 Port, 110V/220V AC input), 19" rack mountable, remote management capable AP300 Power Supply Power Supply ACC-AP300-PWR-xx © 2008 Meru Networks, Inc. Description External Universal Power supply for AP300 series AP Accessories 99 AP300 Accessories All power supply orders must specify the country to configure for correct power cord. Country is specified via 2 letter suffex after the part number (-xx). Countries available include: US (United States), JP (Japan), UK (United Kingdom), EU (Europe), SG (Singapore), HK (Hong Kong), AU (Australia), and KR (Korea), IL (Israel). If no country option is specified, a US power supply is provided. AP300 Antennas Antenna Description MN-ACC-ANTabg-W Meru Standard White Dual Band 802.11 a/b/g Omindirectional Antenna - 2.4 Ghz (2dBi) and 5 Ghz (3 dBi) (Quantity 1 only) ACC-ANT-ABGN-23 Dual Band ceiling mount omnidirectional MIMO antenna with 2/3 dBi gain, with low profile ceiling mount for indoor applications requiring coverage of multiple bands with minimum visibility. Includes three 3' RPSMA pigtails to connect to a 3x3 802.11n AP. It is designed to be easily mounted to drop ceiling tiles or to a solid ceiling surface where cable routing access is available. Use 1 antenna per radio, for example AP310 will need 1 unit, and AP320 will need 2 units ACC-ANT-ABGN47O Optional High gain dipole omnidirectional antenna for AP300. At 4 inches, this antenna is a compact, cosmetically attractive dual-band antenna covering 2.45 and 5.8GHz bands. The antenna attaches using Part 15 compliant RP-SMA connector and offers gain of 4.7dBi for both bands, color black. (Quantity 1 only) AP300 Mounting Options Antenna ACC-ANT-MIMO-MNT 100 Meru AP300 Installation Guide Description Dual band Ceiling and Wall MIMO antenna mount. Mount allows deploying AP300 above the ceiling or inside the enclosure while remotely connecting the antenna to this external Mount. Mount is designed to be aesthetically placed below the ceiling tile or on the wall. Use 1 mount per radio, for example AP310 will need 1 unit, and AP320 will need 2 units © 2008 Meru Networks, Inc. AP200 Accessories Antenna Description ACC-MNT-SCRMKIT Suspended Ceiling Rail Mounting Kit. Works with Meru AP150, AP200 and AP300 ACC-MNT-ASCMKIT Suspended Above Ceiling Mounting Kit (T-Bar Hanger). Works with Meru AP150, AP200 and AP300 AP200 Accessories This section provides specifications for the following AP200 Accessories: z AP200 PoE Devices z AP200 Power Supply z AP200 Antennas z AP200 Mounting Options OAP1800 Accessories This section provides specifications for the following AP200 Accessories: z AP200 PoE Devices z AP200 Power Supply z AP200 Antennas z AP200 Mounting Options AP150 Accessories This section provides specifications for the following AP200 Accessories: © 2008 Meru Networks, Inc. AP Accessories 101 AP150 Accessories z AP200 PoE Devices z AP200 Power Supply z AP200 Antennas z AP200 Mounting Options 102 Meru AP300 Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Appendix C Mounting Bracket Stencils B-1 This appendix provides drawings of the AP mounting brackets. AP150 and AP300 Rev A Mounting Bracket Stencil The following page contains the stencil of the mounting bracket used by AP150 and AP300 Rev A. This stencil should be printed to scale and verified against an actual mounting bracket before punching holes © 2008 Meru Networks, Inc. Mounting Bracket Stencils 103 Internal Use Only—Beta Draft AP150 and AP300 Rev A Mounting Bracket Stencil 104 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft AP300 Rev B Mounting Bracket Stencil AP300 Rev B Mounting Bracket Stencil The standard mounting bracket (Revision A) was redesigned in June 2008 and replaced with a Revision B. This bracket has an extra 3/8th inch clearance from the wall to provide easier access when securing the AP onto the mounted bracket. The Revision B bracket also has enhancements for easier mounting compatibility with existing mounting brackets for various access points such as Meru AP200, Meru AP150, Proxim AP4000, Cisco 1230 Series Access Point, and Cisco 1240 Series Access Points. The following page contains the stencil of the AP300 Rev B mounting bracket. This stencil should be printed to scale and verified against an actual mounting bracket before punching holes © 2008 Meru Networks, Inc. Mounting Bracket Stencils 105 Internal Use Only—Beta Draft AP300 Rev B Mounting Bracket Stencil 106 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Appendix D Cautions and Warnings The cautions and warnings that appear in this manual are listed below in English, German, French, and Spanish. Cautions A Caution calls your attention to a possible hazard that can damage equipment. "Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre attention sur un risque possible d'endommagement de l'équipement. Ci-dessous, vous trouverez les mises en garde utilisées dans ce manuel. Un mensaje de precaución le advierte sobre un posible peligro que pueda dañar el equipo. Las siguientes son precauciones utilizadas en este manual. Caution! When changing the orientation of the antennas, be sure to slightly loosen the knurled ring before moving the antenna. Retighten the ring afterward. Otherwise, you might damage the internal cabling in the AP. Vorsicht! Bei einer Neuausrichtung der Antennen muss vor Bewegung der Antenne der Rändelring leicht gelockert werden. Anschließend den Ring wieder festziehen. Anderenfalls können die internen Kabel im AP beschädigt werden. Mise en garde En cas de modification d’orientation des antennes, veiller à desserrer légèrement la bague moletée avant de réorienter l’antenne. Resserrer ensuite la bague, faute de quoi le câblage interne du point d’accès pourrait être endommagé. Precaución! Al cambiar la orientación de las antenas, asegúrese de aflojar ligeramente el anillo estriado antes de mover la antena. Luego vuelva a apretar el anillo. De otro modo, podría dañar el cableado interno del punto de acceso. Cautions and Warnings 107 Internal Use Only—Beta Draft Cautions Caution! Be sure to connect the Ethernet cable to the Ethernet port; the cable can mistakenly be plugged into the Console port. Vorsicht! Darauf achten, dass das Ethernetkabel am Ethernetanschluss und nicht versehentlich am Konsolenanschluss angeschlossen wird. Mise en garde Veiller à bien connecter le câble Ethernet au port Ethernet et non pas au port Console. Precaución! Asegúrese de conectar el cable Ethernet al puerto Ethernet, porque por error se puede enchufar en el puerto de la consola. Caution! The radiated output power of the Meru Networks, Inc. devices is well below the FCC radio frequency exposure limits. However, the Meru Access Points should be used in such a manner that the potential for human contact during normal operation is minimized. To avoid the possibility of exceeding the FCC radio frequency exposure limits, you should keep a distance of at least 20 cm between you (or any other person in the vicinity) and the Access Point antennas. Vorsicht! Die abgestrahlte Ausgangsleistung von Geräten von Meru Networks, Inc. liegt weit unter den Hochfrequenz-Expositionsgrenzwerten der FCC. Die Meru Access Point Zugangspunkte von Meru Networks, Inc. sollten jedoch so verwendet werden, dass das Potenzial für Kontakt mit Menschen während des normalen Betriebs auf ein Mindestmaß beschränkt wird. Um die Möglichkeit einer Überschreitung der FCC-HochfrequenzExpositionsgrenzwerte zu vermeiden, ist ein Abstand von mindestens 20 cm zwischen Ihnen (bzw. einer anderen Person in der Nähe) und den Zugangspunkt-Antennen zu wahren. Mise en garde La puissance de rayonnement émise par les équipements Meru Networks, Inc. est très inférieure aux limites d'exposition aux fréquences radio définies par la FCC. Toutefois, les points d'accès de la série Meru Access Point de Meru Networks, Inc. doivent être utilisés de façon à éliminer tout risque de contact humain en fonctionnement normal. Pour éviter de dépasser les limites d'exposition aux fréquences radio définies par la FCC, il est impératif de préserver en permanence une distance supérieure ou égale à 20 cm entre l'utilisateur (ou toute personne se trouvant à proximité) et les antennes du point d'accès. Precaución! La potencia de radiación de los dispositivos de Meru Networks, Inc. está muy por debajo de los límites de exposición a radiofrecuencia estipulados por la FCC. No obstante, los puntos de acceso de la serie Meru Access Point de Meru Networks, Inc. deben usarse de tal manera que se minimice la posibilidad de contacto para el usuario durante la operación normal. Para evitar la posibilidad de exceder los límites de exposición a radiofrecuencia establecidos por la FCC, el usuario (o cualquier otra persona en torno) debe mantenerse a una distancia de al menos 20 cm respecto a las antenas del punto de acceso. 108 Meru Access Point and Radio Switch Installation Guide Internal Use Only—Beta Draft Cautions Caution! Exposure to Radio Frequency Radiation. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit an RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb. Vorsicht! Exposure to Radio Frequency Radiation. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit an RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada's website http://www.hc-sc.gc.ca/rpb. Mise en garde Exposition aux rayonnements à fréquence radioélectrique L'installateur de cet équipement radio doit veiller à positionner et orienter l'antenne de telle sorte qu'elle n'émette pas un champ radioélectrique supérieur aux limites définies par Santé Canada pour la population générale. Consulter le Code de sécurité n° 6, disponible sur le site Web de Santé Canada à l'adresse http://www.hcsc.gc.ca/rpb. Precaución! Exposición a la radiación de radiofrecuencia. El instalador de este equipo de radio debe cerciorarse de que la antena está localizada u orientada de tal manera que no emita un campo de radiofrecuencia superior a los límites estipulados por Health Canada para la población; consulte el Código de Seguridad 6 que podrá encontrar en el página web de Health Canada, http://www.hc-sc.gc.ca/rpb. Caution! It is important that you review the contents of Appendix E, “Regulatory Information” before performing the RS4000 installation. Vorsicht! Es ist wichtig, dass Sie vor der Durchführung der RS4000-Installation mit dem Inhalt von Appendix E, “Regulatory Information” vertraut sind. Mise en garde Il est important de consulter le contenu de l'Annexe B, " Informations réglementaires” (Appendix E, “Regulatory Information”) avant l'installation du RS4000. Precaución! Es importante que usted revise los contenidos del Apéndice B, "Información sobre la normativa" (Appendix E, “Regulatory Information”) antes de efectuar la instalación de la unidad RS4000. Cautions and Warnings 109 Internal Use Only—Beta Draft Warnings Warnings A warning calls your attention to a possible hazard that can cause injury or death. The following are the warnings used in this manual. "Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führen können. Sie finden die folgenden Warnhinweise in diesem Handbuch: Un avertissement attire votre attention sur un risque possible de blessure ou de décès. Ci-dessous, vous trouverez les avertissements utilisés dans ce manuel. Una advertencia le llama la atención sobre cualquier posible peligro que pueda ocasionar daños personales o la muerte. A continuación se dan las advertencias utilizadas en este manual. Warning! With plastic covers removed, this product is suitable for use in environmental air space in accordance with the Section 300-22(c) of the National Electric Code and Sections 2- 128.12 - 010 (3) and 12 - 100 of the Canadian Electrical Code. Part 1. C22. 1. For other countries, consult local authorities for regulations. Achtung! Bei abgenommener Kunststoffabdeckung ist dieses Produkt zur Verwendung in einem Umgebungsluftraum gemäß Abschnitt 300-22(c) des National Electric Code und Abschnitt 2- 128.12 - 010 (3) und 12 - 100 des Canadian Electrical Code Teil 1. C22.1 geeignet. Die Vorschriften für andere Länder sind bei den örtlichen Behörden erhältlich. Avertissement Sous réserve que ses couvercles de plastique soient déposés, cet appareil est adapté à une utilisation dans les vides de construction des bâtiments selon la section 300-22(c) du code NEC (National Electric Code) et les sections 2128.12 - 010 (3) et 12 - 100 du Code électrique du Canada, partie 1. C22. 1. Pour tous les autres pays, consulter les organismes de réglementation locaux. Advertencia Una vez desprendidas las cubiertas de plástico, este producto es adecuado para su uso en el espacio aéreo circundante en conformidad con la sección 300-22(c) del National Electric Code (Código Eléctrico Nacional de EE.UU.) y las secciones 2- 128.12 - 010 (3) y 12 - 100 del Código Eléctrico de Canadá. Parte 1. C22. 1. En otros países, consulte a las autoridades locales competentes para informarse acerca de las normativas vigentes. 110 Meru Access Point and Radio Switch Installation Guide Internal Use Only—Beta Draft Warnings Warning! The AP200 with the metal enclosure exposed meets the requirements for fire resistance and low smoke-generating characteristics required by Section 30022(C) of the National Electrical Code (NEC) for installation in a building’s environmental air space. You must remove the plastic enclosure to reveal the plenum-rated AP200 metal case for installations above a suspended ceiling. Additionally, you must use Ethernet cable that meets the requirements for operating in plenums and environmental air space (in accordance with Section 300-22(C) of the NEC). Achtung! Das AP200 mit exponiertem Metallgehäuse erfüllt die Anforderungen für Feuerbeständigkeit und Kenndaten für geringe Raucherzeugung, die gemäß Abschnitt 300-22(C) des National Electrical Code (NEC) zur Installation im Umgebungsluftraum eines Gebäudes vorgeschrieben sind. Bei Installationen über einem Hängeboden muss das Kunststoffgehäuse abgenommen werden, um das flammwidrige (plenum-rated) AP200 Metallgehäuse freizulegen. Außerdem muss ein Ethernetkabel, das die Anforderungen zum Betrieb in einem Umgebungsluftraum erfüllt, verwendet werden (gemäß Abschnitt 300-22(C) des NEC). Avertissement L’équipement AP200 en boîtier métallique à nu est conforme aux critères de résistance au feu et de faible génération de fumées de la section 30022(C) du code NEC (National Electrical Code) pour installation dans le vide de construction d’un bâtiment. Il est nécessaire de déposer le boîtier de plastique pour mettre à nu le boîtier métallique du AP200 en vue de son installation au-dessus d’un faux plafond. De plus, selon la section 300-22(C) du code NEC, le câble Ethernet doit répondre aux critères de fonctionnement en vide de construction. Advertencia La unidad AP200 con la carcasa de metal expuesta cumple los requisitos de resistencia al fuego y de generación de humo especificados en la sección 300-22(C) del National Electrical Code (NEC, Código Eléctrico Nacional de EE.UU.) para la instalación en el espacio aéreo circundante del edificio. Es necesario desprender la cubierta de plástico con el fin de exponer la carcasa metálica de la unidad AP200 plenum para su instalación encima de techos falsos. Por otra parte, es necesario utilizar cable Ethernet que cumpla los requisitos de funcionamiento en el espacio aéreo circundante (en conformidad con la sección 30022(C) del NEC). Cautions and Warnings 111 Internal Use Only—Beta Draft Warnings Warning! Any Fast Ethernet (FE) cables installed in air-handling spaces should be suitable under NEC Article 800.50 and marked accordingly for use in plenums and airhandling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP (Multi Purpose Plenum), or CMP (Communications Plenum). Achtung! Alle Fast-Ethernet (FE)-Kabel, die in Lüftungsräumen installiert werden, sollten gemäß NEC Artikel 800.50 geeignet sein und entsprechend zur Verwendung in Hohlräumen (Plenum) und Lüftungsräumen im Hinblick auf Rauchausbreitung gekennzeichnet sein, z.B. CL2-P, CL3-P, MPP (Multi Purpose Plenum) oder CMP (Communications Plenum). Avertissement Les câbles Fast Ethernet (FE) installés dans un vide d’air doivent correspondre aux critères de l’article 800.50 du code NEC et identifiés en conséquence comme adaptés à une utilisation dans les vides de construction des bâtiments en matière de propagation de la fumée (marquages CL2-P, CL3-P, MPP (Multi Purpose Plenum) ou CMP (Communications Plenum)). Advertencia Todos los cables Fast Ethernet (FE) instalados en espacios aéreos deben cumplir con el artículo 800.50 del NEC y estar marcados adecuadamente para su uso en espacios aéreos y plenums en lo concerniente a la propagación de humo, tales como CL2-P, CL3-P, MPP (Plenum multifuncional), o CMP (Plenum de comunicaciones). 112 Meru Access Point and Radio Switch Installation Guide Internal Use Only—Beta Draft Warnings Warning! Inside antennas must be positioned to observe minimum separation of 20 cm. (~ 8 in.) from all users and bystanders. For the protection of personnel working in the vicinity of inside (downlink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed. The installation of the indoor antenna must be such that, under normal conditions, all personnel cannot come within 20 cm. (~ 8.0 in.) from any inside antenna. Exceeding this minimum separation will ensure that the employee or bystander does not receive RF-exposure beyond the Maximum Permissible Exposure according to FCC CFR 47, section 1.1310 i.e. limits for General Population/Uncontrolled Exposure. Achtung! Innenantennen müssen so positioniert werden, dass ein Mindestabstand von 20 cm (ca. 8 Zoll) zu allen Benutzern und anderen Personen gewahrt wird. Zum Schutz von Personal, das in der Nähe von Innenantennen (Downlink) arbeitet, sind die folgenden Richtlinien für Mindestabstand zwischen dem menschlichen Körper und der Antenne zu beachten. Die Innenantenne muss so installiert werden, dass sich unter normalen Bedingungen kein Personal bis auf weniger als 20 cm (ca. 8 Zoll) an eine Innenantenne annähern kann. Durch Überschreitung dieses Mindestabstands wird sichergestellt, dass Mitarbeiter oder andere Personen keiner RF-Exposition über die maximal zulässige Exposition (MPE; Maximum Permissible Exposure) gemäß FCC CFR 47, Abschnitt 1.1310 (Grenzwerte für die allgemeine Bevölkerung/unkontrollierte Exposition) ausgesetzt werden. Avertissement Les antennes intérieures doivent être positionnées de façon à respecter une distance minimum de 20 cm par rapport aux utilisateurs et aux tiers. Pour la protection du personnel travaillant à proximité des antennes intérieures (liaison descendante), respecter les directives suivantes pour assurer des distances minimales entre les êtres humains et les antennes. Toute antenne intérieure doit être installée de telle sorte que, dans des conditions normales, le personnel ne puisse s'en approcher à moins de 20 cm. Cette distance minimale est destinée à garantir qu'un employé ou un tiers ne sera pas exposé à un rayonnement radioélectrique supérieur à la valeur maximale autorisée, telle qu'elle est définie dans les limites d'exposition non contrôlées pour la population par la réglementation de la FCC CFR 47, section 1.1310. Advertencia Las antenas interiores deben colocarse de manera que se observe una separación mínima de 20 cm. (~ 8 pulg.) respecto a todos los usuarios y circunstantes. Para la protección del personal que trabaje en las inmediaciones de las antenas interiores (receptoras), deben observarse las siguientes directrices relativas a la distancia mínima entre el cuerpo humano y la antena. La instalación de la antena interior debe efectuarse de tal modo que, en condiciones normales, ningún miembro del personal pueda acercarse a menos de 20 cm. (~ 8,0 pulg.) de cualquier antena interior. El cumplimiento de este mínimo de separación asegura que el empleado o circunstante no recibirá exposición a radiofrecuencia por encima de la Exposición Máxima Permisible conforme a la normativa FCC CFR 47, sección 1.1310, es decir, los límites asignados a la Exposición Incontrolada/Población Civil. Cautions and Warnings 113 Internal Use Only—Beta Draft Warnings 114 Meru Access Point and Radio Switch Installation Guide Internal Use Only—Beta Draft Appendix E Regulatory Information The Meru Access Points (APs) must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. For country-specific approvals, see below. Meru Networks, Inc. is not responsible for any radio or television interference caused by unauthorized modification of APs, or the substitution or attachment of connecting cables and equipment other than that specified by Meru Networks, Inc. The correction of interference caused by such unauthorized modification, substitution or attachment is the responsibility of the user. Meru Networks, Inc. and its authorized resellers or distributors are not liable for any damage or violation of government regulations that may arise from the user failing to comply with these guidelines. For OAP180 Radio z FCC Part 15 z Canada RSS210 z EN 300 328 V1.6.1 (11/2004) z EN 301 893 V1.3.1 (08/2005) z Japan Technical Regulations EMC z FCC Part 15 z EN 301 489-17 V1.2.1 (08/2002) z Japan VCCI Safety Prolonged exposure to RF radiation can be hazardous. Switch off unit power before service or installation procedures. © 2008 Meru Networks, Inc. Regulatory Information 115 Internal Use Only—Beta Draft USA Limits for Occupational/Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) 1500-100,000 Power Density (S) (mW/cm2) Averaging Time |E|2, |H|2 or S (minutes) Limits for General Population/Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) 1500-100,000 Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm2) Averaging Time |E|2, |H|2 or S (minutes) 1.0 30 Note: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. Note: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or can not exercise control over their exposure. Frequencies Blocked for Regulatory Compliance 802.11a frequencies 5.25-5.35 GHz and 5.47-5.725 GHz have been blocked for DFS compliance. USA Underwriters Laboratories For the AP150 series, the AP200 series, the OAP180, and the RS4000, the following statement and notices are applicable: 116 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft USA Use only with Listed I.T.E. equipment. Notices The unit is intended for installation in Environment A as defined in IEEE 802.3.af. All interconnected equipment must be contained within the same building, including the interconnected equipment's associated LAN connection. Suitable for use in environmental air space in accordance with Section 300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1. FCC Radiation Exposure Statement Caution! The radiated output power of the Meru Networks devices is well below the FCC radio frequency exposure limits. However, the Meru Access Points should be used in such a manner that the potential for human contact during normal operation is minimized. When installing and operating these devices, keep a minimum distance of 20 cm (8 inches) between the antennas and any persons/users in the vicinity. Radio Frequency Interference Requirements The Interference Statement applies to the following APs: z AP150 z OAP180 z AP201 Rev 2, AP208 Rev 2 FCC Part 15 Statement This is to certify that the above models are shielded against the generation of radio interference. Compliance is dependent upon the use of Cat 5e shielded data cables or a Meru-supplied line filter. Contact Meru Support to obtain a line filter, free of charge. z AP300 series z RS4000 © 2008 Meru Networks, Inc. Regulatory Information 117 Internal Use Only—Beta Draft USA Interference Statement Meru Access Points Note: These devices are restricted to indoor use because they operate in the 5.15 to 5.25 GHz frequency range. The FCC requires such products to be used indoors for the frequency range 5.15 GHz to 5.25 GHz to reduce the potential for harmful interference to co-channel Mobile Satellite systems. High-power radars are allocated as primary users of the 5.25 to 5.35 GHz and 5.65 to 5.85 GHz bands. These radar stations can cause interference with or damage to these devices, or both. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If the equipment is not installed and used in accordance with the instructions, the equipment may cause harmful interference to radio communications. There is no guarantee, however, that such interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception (which can be determined by turning the equipment off and on), the user is encouraged to try to correct the interference by taking one or more of the following measures: z Reorient or relocate the receiving antenna. z Increase the separation between the equipment and receiver. z Connect the equipment into an outlet on a circuit different from to which the receiver is connected. z Consult the dealer or an experienced radio/TV technician for help. Note: The Meru Access Point must be installed and used in strict accordance with the manufacturer’s instructions as described in the user documentation that comes with the product. Any other installation or use may violate FCC Part 15 regulations. Modifications not expressly approved by Meru Networks, Inc. could void your authority to operate the equipment. This device must not be co-located or operating in conjunction with any other antenna or transmitter. For products available in the USA and Canadian markets, only channels 1 through 11 can be operated. Selection of other channels is not authorized. 118 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Canada. Industry Canada (IC) Canada. Industry Canada (IC) The Class B digital portion of this apparatus complies with Canadian standard ICES003. These devices comply with RSS210 of Industry Canada. Per RSS 210 A9.5 point 7: (i) the device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems; (ii) the maximum antenna gain permitted (for devices in the bands 5250-5350 MHz and 5470-5725 MHz) to comply with the e.i.r.p. limit; and (iii) the maximum antenna gain permitted (for devices in the band 5725-5825 MHz) to comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate, as stated in section A9.2(3). In addition, users should also be cautioned to take note that high-power radars are allocated as primary users (meaning they have priority) of the bands 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LELAN devices. (iv) These devices are not permitted to operate in the 5600 - 5650 MHz band. For products available in the USA and Canadian markets, only channels 1 through 11 can be operated. Selection of other channels is not authorized. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device. This device and its listed antenna(s) must not be co-located or operated in conjunction with any other antenna or transmitter L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit pas produire de brouillage et (2) l’utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif. The term "IC" before the equipment certification number only signifies that the Industry Canada technical specifications were met. To reduce the potential radio interference to other users, the antenna type and gain should be chosen so that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. To prevent radio interference to the licensed service, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing. Pour empecher que cet appareil cause du brouillage au service faisant l’objet d’une licence, il doit etre utilze a l’interieur et devrait etre place lin des fenetres afin de Fournier un ecram de blindage maximal. Si le matriel (ou son antenne d’emission) est installe a l’exterieur, il doit faire l’objet d’une licence. © 2008 Meru Networks, Inc. Regulatory Information 119 Internal Use Only—Beta Draft Canada. Industry Canada (IC) Exposure to Radio Frequency Radiation. Caution! The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit an RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website http://www.hc-sc.gc.ca/rpb. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the antennas and any persons/users in the vicinity. Meru Access Points Note: These devices are restricted to indoor use because they operate in the 5.15 to 5.25 GHz frequency range. Industry Canada requires such products to be used indoors for the frequency range 5.15 GHz to 5.25 GHz to reduce the potential for harmful interference to co-channel Mobile Satellite systems. Access Points have been designed to operate with the antennas listed below. Antennas not included in this list are strictly prohibited for use with these devices. The required antenna impedance is 50 ohms. Table 19: AP Antennas with Gain AP Model Antenna Type Gain (2.4 GHz) Gain (5 GHz) AP300 Dual-Band Omni-Directional MN-ACC-ANTabg-W 2 dBi 3 dBi AP300 Dual-Band Omni-Directional ACC-ANT-ABGN-23 2 dBi 3 dBi AP300 High-Gain Dipole Omni-Directional ACC-ANT-ABGN47O 4.7dBi 4.7dBi 2 dBi 3 dBi 4 dBi 5 dBi 2 dBi 3 dBi AP200 AP200 AP150 120 Dual-Band Omni-Directional SAA04-220050 Dual-Band Omni-Directional TWX-614XRSXX Dual-Band Omni-Directional SAA04-220050 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Europe—EU Declaration of Conformity and Restrictions Dual-Band Multi-Channel OmniDirectional RS4000 4 dBi 4.5 dBi 5 dBi 5.5 dBi MN-ACC-ANTRSO Dual-Band Multi-Channel 180 o RS4000 MN-ACC-ANTRSOH To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. Europe—EU Declaration of Conformity and Restrictions This equipment is marked with either the CE Mark, the alert symbol, and the notified body's number and can be used throughout the European Community. This mark indicates compliance with the R&TTE Directive 1999/5/EC and the relevant parts of the following technical specifications. EN 300 328. Electromagnetic Compatibility and Radio Spectrum Matters (ERM). Wideband transmission systems, data transmission equipment operating in the 2.4 GHz ISM (Industrial, Scientific, and Medical frequency bands in the range of 902–928 MHz, 2.4–2.485 GHz, and 5.15–5.25 GHz) band and using spread spectrum modulation techniques, harmonized EN standards covering essential requirements under article 3.2 of the R&TTE directive. EN 301 893. Broadband Radio Access Networks (BRAN). 5 GHz high-performance RLAN, harmonized EN standards covering essential requirements of article 3.2 of the R&TTE directive. EN 301 489-17. Electromagnetic Compatibility and Radio Spectrum Matters (ERM). Electromagnetic Compatibility (EMC) Standard for Radio Equipment and Services, Part 17 Specific Conditions for Wideband Data and HIPERLAN Equipment. EN 55022 Statement (applicable to AP201 Rev 2, AP208 Rev 2 only).This is to certify that the above models are shielded against the generation of radio interference in accordance with the application of Council Directive 2004/108/EC, Annex I, 1a. Conformity is declared by the application of EN 55 022 Class B (CISPR 22). Compliance is dependent upon the use of Cat 5e shielded data cables. EN 60950-1. Safety of Information Technology Equipment. © 2008 Meru Networks, Inc. Regulatory Information 121 Internal Use Only—Beta Draft Europe—EU Declaration of Conformity and Restrictions EN 50385. Product standard to demonstrate the compliances of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fields. Marking by the alert symbol indicates that usage restrictions apply. Meru Networks, Inc. declares that their Access Points comply with the essential requirements and other relevant provisions of Directive 1999/5/EC. Meru Networks, Inc. vakuuttaa täten että Access Points tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. Hierbij verklaart Meru Networks, Inc. dat het toestel Access Points in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Bij deze verklaart Meru Networks, Inc. dat deze Access Points voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC. Par la présente, Meru Networks, Inc. déclare que l’appareil Access Points est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Par la présente, Meru Networks, Inc. déclare que ce Access Points est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables. Härmed intygar Meru Networks, Inc. att denna Access Points står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. Undertegnede Meru Networks, Inc. erklærer herved, at følgende udstyr Access Points overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Hiermit erklärt Meru Networks, Inc. dass sich dieser/diese/dieses Access Points in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet. Hiermit erklärt Meru Networks, Inc. die Übereinstimmung des Gerätes Access Points mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. Π Α Ρ Ο Ψ Σ Α Fo u nd ry N e tw o rks In c. ∆ Η Λ Ω Ν Ε Ι Ο Τ Ι A cce ss P o in ts Ρ Φ Ω Ν Ε Τ Α Ι Π Ρ Ο Σ Τ ΙΣ Ο Υ Σ ΙΩ ∆ Ε ΙΣ Α Π Α ΙΤ Η Σ ΙΣ Κ Α Ι Τ ΙΣ Λ Ο ΙΠ Ε Σ Σ Χ Ε Τ ΙΚ Ε Σ Ε ΙΣ Τ Η Σ Ο ∆ Η ΓΙΑ Σ 19 9 9/5 /Ε Κ . 122 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Europe—EU Declaration of Conformity and Restrictions Con la presente Meru Networks, Inc. dichiara che questo Access Points è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Por medio de la presente Meru Networks, Inc. declara que el Access Points cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Meru Networks, Inc. declara que este Access Points está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Hawnhekk, Meru Networks, Inc. jiddikjara li dan Access Points jikkonforma malhtigijiet essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Käesolevaga kinnitab Meru Networks, Inc. seadme Access Points vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. Alulírott, Meru Networks, Inc. nyilatkozom, hogy a Access Points megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Meru Networks, Inc. týmto vyhlasuje, e Access Points splna základné poiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Meru Networks, Inc. tímto prohlašuje, e tento Access Points je ve shode se základními poadavky a dalšími príslušnými ustanoveními smernice 1999/5/ES. Šiuo Meru Networks, Inc. deklaruoja, kad šis Access Points atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Ar šo Meru Networks, Inc. deklare, ka Access Points atbilst Direktivas 1999/5/EK butiskajam prasibam un citiem ar to saistitajiem noteikumiem. Niniejszym, Meru Networks, Inc., deklaruje, ze Access Points spelnia wymagania zasadnicze oraz stosowne postanowienia zawarte Dyrektywie 1999/5/EC. These products are intended to be used in all countries of the European Economic Area with the following restrictions: IEEE 802.11a Restrictions z These products are for indoor use only (5150–5250 MHz). z To ensure compliance with local regulations, be sure to set your Access Point to the country in which you are using the Access Point. z The Meru Networks, Inc. products can be used only indoors in the following countries: Austria, Belgium, Bulgaria, Czech Republic, Germany, Cyprus, Denmark, Estonia, Finland, France, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, The Netherlands, Norway, Portugal, Poland, Romania, Spain, Slovak Republic, Slovenia, Sweden, Switzerland, Turkey, and United Kingdom. © 2008 Meru Networks, Inc. Regulatory Information 123 Internal Use Only—Beta Draft Japan EEE 802.11b/g Restrictions z France—In all Metropolitan départements, wireless LAN frequencies can be used under the following conditions, either for public or private use: Indoor use: maximum power (EIRP) of 100 mW for the entire 2400–2483.5 MHz frequency band. Japan EN 55022 Statement (applicable to AP201 Rev 2, AP208 Rev 2 only).This is to certify that the above models are shielded against the generation of radio interference in accordance with the application of Council Directive 2004/108/EC, Annex I, 1a. Conformity is declared by the application of EN 55022 Class B (CISPR 22). Compliance is dependent upon the use of shielded data cables. Model AP300 003NY07015 0000 003GZ07003 0000 003WY07005 0000 003GZ06018 0000 003WY06035 0000 Model 208 003NY06089 0000 Model 208 Rev 2 Module 003NY07014 0000 003GZ07002 0000 003WY07004 0000 Model AP208 Rev 2 003NY07015 0000 003GZ07003 0000 003WY07005 0000 003GZ06026 0000 003WY06043 0000 Model 201 003NY06117 0000 124 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. Internal Use Only—Beta Draft Manufacturing Information Model AP201 Rev 2 003NY07015 0000 003GZ07003 0000 003WY07005 0000 003GZ06030 0000 003WY06046 0000 Model AP150 003NY06122 0000 Singapore For the AP201 Rev 2, AP208 Rev 2, and OAP180, the following approval information applies: Complies with IDA Standards DA103798 Manufacturing Information The AP150, AP200, and AP300 are built in Taiwan. Factory information is provided under NDA and upon request. AP300 Plenum Requirements When installing the product in an air-handling space, as described in Article 300.22(C) of the NEC (2005), the unit should only be powered by the Ethernet port (PoE), not by the AC-powered power supply. When the product is installed in air-handling spaces, the cables employed should be suitable under NEC Articles 300.22 and 725 and marked accordingly, for use in plenums and air-handling spaces with regard to smoke propagation, such as CL2-P, CL3-P, MPP or CMP. The products should be installed in accordance with all applicable, local regulations and practices. © 2008 Meru Networks, Inc. Regulatory Information 125 Internal Use Only—Beta Draft AP300 Plenum Requirements 126 Meru Access Point and Radio Switch Installation Guide © 2008 Meru Networks, Inc. MERU NETWORKS, INC. Limited Product Warranty This Limited Product Warranty applies to the original end-user customer of the Meru product which you purchased for your own use, and not for resale (“Product”), from Meru Networks, Inc. (“Meru”) or its authorized reseller (“Reseller”). Limited Warranties — One-year limited hardware warranty: Meru warrants to you that Meru hardware (other than Third Party Products as described below) will be free from defects in materials and workmanship for a one-year period after the date of delivery of the applicable product to you from Meru or its Reseller (the “Hardware Warranty Period”). If Meru receives written notice from you of such defects during the Hardware Warranty Period, Meru will, at its option, either repair or replace Meru hardware that Meru determines to be defective. Replacement products may be remanufactured units, and will be warranted for the remainder of the original Hardware Warranty Period, or if greater, for thirty days from delivery of such replacement. Should Meru be unable to repair or replace the Meru hardware, Meru (or its Reseller, as applicable) will refund to you the purchase price of the Product. — 90-Day Limited Software Warranty: Meru warrants to you that, for a 90-day period after the date of delivery of the applicable product to you from Meru or its Reseller (the “Software Warranty Period”), when properly installed and used, (a) the media on which the Meru software is provided will be free from defects in materials or workmanship; and (b) the Meru software will substantially conform to the functional specifications in the applicable documentation. If Meru receives written notice from you of a breach of this warranty during the Software Warranty Period and is able to reproduce the defect, Meru will, at its option, either repair or replace the defective Meru software. Should Meru be unable to repair or replace the Meru software, Meru (or its Reseller, as applicable) will refund to you the purchase price of the Product. Exclusions The warranty on the Product shall not apply to defects resulting from the following: — Alteration or modification of the Product in any way, including without limitation configuration with software or components other than those supplied by Meru or integration with parts other than those supplied by Meru. — Abuse, damage or otherwise being subjected to problems caused by negligence or misapplication (including without limitation improper or inadequate maintenance or calibration), relocation of the products (including without limitation damage caused by use of other than Meru shipping containers), or use of the products other than as specified in the applicable Meru product documentation (including without limitation incompatible operating environments and systems), or improper site preparation or maintenance. — Damage as a result of accidents, extreme power surge, extreme electromagnetic field, acts of nature or other causes beyond the control of Meru. — Use of the Product with software, interfacing, parts or supplies not supplied by Meru. The warranty on the Product does not apply if the Product is sold, or in the case of software, licensed, for free for evaluation or demonstration purposes. 127 Meru expressly disclaims any warranty or obligation to support the Product for all operating environments – for example, as illustration and not limitation, Meru does not warrant or ensure interoperability of the Product with future telecommunication systems or other future software or hardware. You understand and acknowledge that the Products may generate, use or radiate radio frequency energy and may interfere with radio communications and/or radio and television receptions if is not used and/or installed in accordance with the documentation for such products. WHILE MERU USES COMMERCIALLY REASONABLE EFFORTS TO ENSURE COMPLIANCE OF THE PRODUCTS WITH APPLICABLE UNITED STATES FEDERAL COMMUNICATIONS COMMISSION AND PROTECT AGAINST HARMFUL INTERFERENCES, YOU ACKNOWLEDGE AND AGREE THAT INTERFERENCES WITH RADIO COMMUNICATIONS AND/OR RADIO AND TELEVISION RECEPTIONS MAY OCCUR AND THAT MERU WILL NOT BE LIABLE FOR ANY DAMAGES OR INCONVENIENCE BASED ON SUCH INTERFERENCES. Third Party Products - The above Limited Warranties are exclusive of products manufactured by third parties (“Third Party Products”). If such third party manufacturer provides a separate warranty with respect to the Third Party Product, Meru will include such warranty in the packaging of the Meru Product. Return procedures To obtain warranty service you must: (a) obtain a return materials authorization number (“RMA#”) from Meru by contacting rmaadmin@merunetworks.com, and (b) deliver the Product, in accordance with the instructions provided by Meru, along with proof of purchase in the form of a copy of the bill of sale including the Product’s serial number, contact information, RMA# and detailed description of the defect, in either its original package or packaging providing the Product with a degree of protection equivalent to that of the original packaging, to Meru at the address below. You agree to obtain adequate insurance to cover loss or damage to the Product during shipment. If you obtain an RMA# and return the defective Product as described above, Meru will pay the cost of returning the Product to Meru. Otherwise, you agree to bear such cost, and prior to receipt by Meru, you assume risk of any loss or damage to the Product. Meru is responsible for the cost of return shipment to you if the Meru Product is defective. Returned products which are found by Meru to be not defective, returned out-of-warranty or otherwise ineligible for warranty service will be repaired or replaced at Meru’s standard charges and shipped back to you at your expense. At Meru’s sole option, Meru may perform repair service on the Product at your facility, and you agree to provide Meru with all reasonable access to such facility and the Product, as required by Meru. On-site repair service may be available and is governed by the specific terms of your purchase. All replaced parts, whether under warranty or not, are the property of Meru. Warranty limitations THE WARRANTIES SET FORTH ABOVE ARE EXCLUSIVE AND NO OTHER WARRANTY, WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED BY MERU, TO THE MAXIMUM EXTENT PERMITTED BY LAW. THERE ARE NO OTHER 128 Meru Access Point and Radio Switch Installation Guide WARRANTIES RESPECTING THE PRODUCT AND DOCUMENTATION AND SERVICES PROVIDED UNDER THIS AGREEMENT, INCLUDING WITHOUT LIMITATION ANY WARRANTY OF DESIGN, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (EVEN IF MERU HAS BEEN INFORMED OF SUCH PURPOSE), TITLE OR AGAINST INFRINGEMENT OF THIRD PARTY RIGHTS. IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED UNDER APPLICABLE LAW, THEN SUCH IMPLIED WARRANTY SHALL BE LIMITED IN DURATION TO THE HARDWARE AND SOFTWARE WARRANTY PERIODS DESCRIBED ABOVE. NO AGENT OF MERU IS AUTHORIZED TO ALTER OR EXCEED THE WARRANTY OBLIGATIONS OF MERU. MERU SPECIFICALLY DOES NOT WARRANT THAT THE MERU SOFTWARE WILL BE ERROR FREE OR OPERATE WITHOUT INTERRUPTION. THE REMEDIES IN THIS LIMITED PRODUCT WARRANTY ARE YOUR SOLE AND EXCLUSIVE REMEDIES, AND MERU’S SOLE AND EXCLUSIVE LIABILITY, FOR BREACH OF THE HARDWARE OR SOFTWARE WARRANTY SET FORTH ABOVE. Limitations of Liability You acknowledge and agree that the consideration which you paid to Meru does not include any consideration by Meru of the risk of consequential, indirect or incidental damages which may arise in connection with your use of, or inability to use, the Product. THUS, MERU AND ITS RESELLER WILL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOST PROFITS, LOST BUSINESS, LOST DATA, LOSS OF USE, OR COST OF COVER INCURRED BY YOU ARISING OUT OF OR RELATED TO YOUR PURCHASE OR USE OF, OR INABILITY TO USE, THIS PRODUCT OR THE SERVICES, UNDER ANY THEORY OF LIABILITY, WHETHER IN AN ACTION IN CONTRACT, STRICT LIABILITY, TORT (INCLUDING NEGLIGENCE) OR OTHER LEGAL OR EQUITABLE THEORY, EVEN IF MERU OR ITS RESELLER KNEW OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES. IN ANY EVENT, THE CUMULATIVE LIABILITY OF MERU OR ITS RESELLER FOR ALL CLAIMS WHATSOEVER RELATED TO THE PRODUCT OR THE SERVICE WILL NOT EXCEED THE PRICE YOU PAID FOR THE PRODUCT OR SERVICES GIVING RISE TO SUCH CLAIMS. THE LIMITATIONS SET FORTH HEREIN ARE INTENDED TO LIMIT THE LIABILITY OF MERU AND ITS RESELLERS AND SHALL APPLY NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY. The jurisdiction applicable to you may not allow the limitations of liability or damages set forth above, in which case such limitation shall only apply to you to the extent permitted in such jurisdiction. Additional Information This Limited Product Warranty shall be governed by and construed in accordance with the laws of the State of California, U.S.A., exclusive of its conflict of laws principles. The U.N. Convention on Contracts for the International Sale of Goods shall not apply. 129 This Limited Product Warranty is the entire and exclusive agreement between you and Meru with respect to its subject matter, and any modification or waiver of any provision of this statement is not effective unless expressly set forth in writing by an authorized representative of Meru. All inquiries or claims made under this Limited Product Warranty must be sent to Meru at the following address: Meru Networks Inc., 894 Ross Drive, CA 94087, USA Tel: 408-215-5300 Fax: 408-215-5301 Email: support@merunetworks.com 130 Meru Access Point and Radio Switch Installation Guide Meru Networks, Inc. 894 Ross Drive Sunnyvale, CA 94087 408-215-5300 www.merunetworks.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 145 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:d16d3637-0a0e-4d30-972d-2f16305ee9e8 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : FrameMaker 7.0 Modify Date : 2008:07:02 11:20:31Z Create Date : 2008:07:02 11:20:31Z Document ID : uuid:a8d451d7-fcfc-404c-86bf-a43dd63165ba Format : application/pdf Title : AP_Install.book Creator : mpage Author : mpageEXIF Metadata provided by EXIF.tools