Mettler Toledo 2018MT102 Bluetooth Module ACW520 User Manual
Mettler Toledo (Changzhou) Measurement Technology Ltd. Bluetooth Module ACW520 Users Manual
User Manual
6.3 FCC Part 15.21 The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. To satisfy FCC RF exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Specifications Model ACW520-BT No. 1.4 FCC Part 2.1093 Bluetooth Bluetooth Module ACW520 Packing List Name ACW520-BT Bluetooth Module Quick Guide Quantity Note CAUTION Unauthorized person is not allowed to disassemble the product. Do not use the device in hazardous environment! Quick Guide Note: METTLER TOLEDO reserves the right to modify the instructions ACW 520 –B T Bluetooth module Product line BT Version Size of box Size of package Power Power Consumption Display Working Temperature Ambient humidity ( Accessory: communication module Bluetooth 5.0 downward compatible 4.1 4.2 68 x 26 x 98 mm 70 x 70 x 100 mm DC 3.3 12 V 5V/15mA Red/green/yellow indicating light -10 40 、 ) ( ~ ) ℃~ ℃ Humidity =<85% For more information ACW520-BT 1. Assemble * Working mode and slave and master inquiring Plug the joint of ACW520-BT directly into the joint of the device that need to be connected, and then the adapter will start automatically The red light of ACW520-BT will flash once when starting. Single click the multi-function button, the times of flashing indicates the working mode and the color indicates slave or master. Indication light Salve or Working mode flashing master * How to ensure the ACW520-BT has started yellow twice transparent transmission slave After the connection, short press the multi-function button. If the indicating light flashes, that means the Bluetooth has started. green twice transparent transmission master 4. Transmission mode 2. Pairing Operating as below after confirmed the starting of ACW520-BT: (1)Long press the ACW520-BT in the scale until the yellow indicating light flash once. (2)Long press the ACW520-BT which is connected to terminal, until the yellow indicating light flash twice. (3)once the two adapters connect successfully, the green lights of both flash once. master In the scale With the terminal *search for the corresponding paired ACW520-BT through ACW520-BT After power on the adapter, single click the multi-function button, the indication light of paired adapter will flash at the same time. Yellow light flashing means salve and green light flashing means master. 3. Working mode Bluetooth adapter ACW520-BT can work in the mode of transparent transmission: Working mode Description Transparent transmission Data transmitted in both directions between the serial port and the ACW520-BT interface directly Slave Working mode √ Transparent transmission Transmission mode √ One to One √ 115200 Baud rate *Transmission mode inquiring This device complies with part 15 of the FCC rules. Part 15C red color slave None √ Triple slick the multi-function button, and the flashing times correspond to different modes. In the operation shown above, the ACW520-BT connected to scale is slave and the ACW520-BT connected to terminal is master. Configuration type √ Master and slave info. 6. FCC STATEMENT: flashing Configuration of master and slave: pairing info. The function is to turn on or off the multiple to one transmission function. In the multiple to one transmission mode, the devices should be set to multi masters and one slave. Choose one as the slave and connect it with other masters in turn. * How to determine master and slave Slave: can be connected by other master devices and will record the address of the master in default when first connected. After that, it will not receive the query from other master. Master: will connect to one of the other paired slaves automatically. The parameters shown below will be reset to default: Reset to Parameter Keep Default default once transmission mode one to one red color Multiple to one (caution: this function is not twice available to wireless floor scale) * How to switch the transmission mode After power on the ACW520-BT, the transmission mode can be switched. To switch the transmission mode, long press the multi-function button until the yellow light flashes three times. Then triple click the button to switch in 5 seconds. After the transmission mode is switched successfully, the adapter will restart automatically and the red light will flash once Name √ Factory preset 6.1 FCC Part 15.105 (b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver Caution: the slave and master should be set to the same transmission mode. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 5. Restore factory settings - Consult the dealer or an experienced radio/TV technician for help . Shortcut: when the ACW520-BT is powered on, double click the multi-function button. Then the ACW520-BT will be reset to factory settings and the red light flashes once to tell you the reset has been done. 6.2 FCC Part 15.19(a)(3) Standard mode: when the ACW520-BT is powered on, long press the paired ACW520-BT until the yellow light flashes three times. Then, short press the multi-function button four times instantly and immediately. The ACW520-BT will also be reset and the red light flashes once. Conditions for Use: This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Producer : GPL Ghostscript 8.15 Create Date : 2018:05:10 15:04:10 Modify Date : 2018:05:10 15:04:10 Title : <4D6963726F736F667420576F7264202D204143573532302D425420C0B6D1C0CACAC5E4C6F7CAB9D3C3CBB5C3F7CAE9D3A2CEC4B0E62E646F6378> Creator : PScript5.dll Version 5.2.2 Author : shen-4EXIF Metadata provided by EXIF.tools