Microlife TWIN200-1 WatchBP Professional User Manual

Microlife Corporation WatchBP Professional

User Manual

Download: Microlife TWIN200-1 WatchBP Professional User Manual
Mirror Download [FCC.gov]Microlife TWIN200-1 WatchBP Professional User Manual
Document ID969979
Application ID2p562nrbz5TaI6XxRgkK5g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize340.24kB (4253061 bits)
Date Submitted2008-07-14 00:00:00
Date Available2008-07-14 00:00:00
Creation Date2008-06-30 11:44:58
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2008-06-30 11:45:12
Document TitleUser Manual
Document CreatorAdobe InDesign CS3 (5.0)

Simultaneous dual-arm
measurement and
auscultatory function for
accurate office blood
pressure measurement.
Instruction Manual
EN
WatchBP Office combines the advantages of an automatic blood pressure device and hybrid
sphygmomanometer and is designed to provide convenient, accurate and reliable in-office
blood pressure measurement following recommended guidelines of the European Society
of Hypertension (ESH) 1, American Heart Association (AHA), and World Health Organization
(WHO).
O’Brien E, Asmar R, Beilin L, Imai Y, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure
measurement. European Society of Hypertension Working Group on Blood Pressure Deviceing. J Hypertens 2003;21:821-848.
Table of Contents
Product description
Name of parts and display.................................. 3–4
Components and accessories.............................. 5–6
Before using WatchBP Office
Selecting and fitting the correct cuff................... 7–8
Three operation modes
«AUSCULTATION» Mode........................................... 9
«1st VISIT» Mode............................................. 10–11
«FOLLOW-UP» Mode.............................................. 12
Taking measurements using WatchBP Office
«AUSCULTATION» Mode................................... 13–14
«1st VISIT» Mode............................................. 15–17
«FOLLOW-UP» Mode........................................ 18–20
Special Functions
Hiding measurement values................................. 21
Mean arterial pressure and pulse pressure .......... 22
Taking fewer than three measurements ............. 23
Skipping the 60-second countdown..................... 23
Setting inflation pressure...................................... 24
Setting measurement intervals............................ 24
Viewing Measurements
«AUSCULTATION» Mode ........................................ 25
«1st VISIT» and «FOLLOW-UP» Mode.............. 25–26
Controlling the WatchBP Office Wirelessly
Setting up the Bluetooth receiver................... 27–28
Installation of the software program.................... 29
Controlling the device wirelessly ................... 29–30
Appendix
Rechargeable battery and power adaptor . ......... 31
Troubleshooting.................................................... 32
Error messages................................................ 33–34
Safety, care, accuracy test and disposal.......... 35–36
Technical specifications........................................ 37
EN
Product description
Name of parts
I/O switch
Bluetooth Switch
Main Adaptor Socket
Battery Compartment
Cuff Socket (R)
DC 6V 600mA
DC 6V 600mA
Cuff Socket (L)
SYS
mmHg
DIA
mmHg
Recharge Indicator
Display
M Button (Memory)
SYS
mmHg
DIA
mmHg
PUL
/min
Mode Switch
I N T E R VA L
Start/Stop Button
3 sec.
L/R
3 sec.
HIDE
7 sec.
7 sec.
AUSCULT 1st FOLLOW UP
Display
Mean Arterial Pressure (MAP)
Pulse Pressure (PP)
Mode Indication
External Power
Value for Left Arm
Systolic Value
Diastolic Value
Bluetooth
Rest and Arm Position Reminder
Battery Symbol
Hide Display
Memory Mode
Pulse Rate
Value for Right Arm
Systolic Value
Diastolic Value
Heart Beat
L/R Cuff
EN
WatchBP Office and components
Bluetooth Receiver
Driver
SYS g
mmH
DIA
mmHg
Install CD
SYS g
mmH
DIA
mmHg
PUL
/min
AUSC ULT
1st FOLLO
UP
WatchBP Office blood
pressure device (1 pcs.)
AC Adaptor X1 (Input:
100-240V~50/60Hz 0.7A
Output: +7.5V 2A)
Bluetooth receiver X1
Install CD X1
Quick start guide
How to take blood presssure measurement in three different modes
1 Plug cuff connector
«1st VISIT» Mode (Double arm)
ght
All R
«AUSCULTATION» Mode
(Single arm)
Flip over the quick start guide to see ‘Product description’.
68
y, 1024x7
Memor
port, 40MB
z CPU. 256MB
free USB
s: 550MH
drive, 1
ement
Vista.
Requir
/ XP /
color, CD-ROM
System
s 2000
ion, 256
ft Window
pixel resolut space, Microso
disk
free hard
WatchBP Office Software
CD X1
Simultaneous
dual-arm
Press Start/Stop
button to begin a
measurement
and
measurement
Note bloodfor
auscultatory function
presure using
accurate in-officeauscultatory
blood
method
pressure measurement.
Place the stethoscope on
the hollow of the elbow,
over the brachial artery
3 Switch the mode
Install CD
An averaged result will
be displayed after three
consecutive measurments
Press Start/Stop
button to begin a
measurement
«FOLLOW-UP» Mode (Single arm)
2 Turn on the device
ration
1.0.2
Version
©2008 Microlife Corpo
Office
d.
rve
ese
sR
in the cuff socket
Analyzer
WatchBP
.4
Instruction Manual
EN
M size (22cm~32cm) X2
L size (32cm~42cm) X2
Manual Instruction X1
Quick Start Guide X1
Selective Cuffs
M (Medium size)
22 - 32 cm (8.75 - 12.5 inches)
With air tube 130 cm
L (Large size)
32-42 cm (12.5-16.5 inches)
With air tube 130 cm
* Please contact Microlife or its distributor to purchase cuffs.
EN
Before using WatchBP Office
Selecting the correct cuff
Fitting the cuff properly
Two different cuff sizes are provided with the
WatchBP Office: Medium and Large. Select the cuff
size that best matches the circumference of the
patient’s upper arm.
1) Place the cuff over the left (right) upper arm so
that the air tube and artery mark arrow point
toward the lower arm.
M (Medium size)
22 - 32 cm (8.75 - 12.5 inches)
2) Lay the cuff on the arm. Make sure that the lower
edge of the cuff lies approximately ¾” to 1”(2 to
3cm) above the elbow.
M is the correct size for most people.
L (Large size)
32-42 cm (12.5-16.5 inches)
Connect the cuff to the device by inserting the cuff
connector into the cuff connector socket.
2–3cm
3) Wrap and tighten the cuff around the arm.
4) Leave a little free space between the arm and
the cuff. The patient should be able to fit 2 fingers
between the arm and the cuff. Clothing must not
restrict the arm. Remove all clothing covering or
constricting the measurement arm.
5) Cuffs that do not fit properly can result in
incorrect blood pressure measurements. Use a
different size cuff if the range Index at the end of
the cuff does not fall into the range specified by
the range stripes.
6) Apply the same steps to the other arm if a double
arm measurement is required.
* The range index of cuff should
be fallen into this range.
EN
Three operation modes
SY S
Choose a desired operationmmHg
mode
«AUSCULTATION» Mode
DIA
The WatchBP Office device includesmmHg
three convenient
operation modes: «AUSCULTATION», «1st VISIT» and
«FOLLOW-UP» Mode.Use the ModeSYSwitch
on the
mmHg
side of the device to select the desired mode.
Select «AUSCULTATION» Mode for blood pressure
measurement of patients with arrhythmia, and,
if needed, to confirm if a patient is suitable for
the oscillometric method using a digital blood
pressure monitor.
DIA
mmHg
PUL
/min
I N T E R VA L
3 sec.
L/R
3 sec.
HIDE
7 sec.
1st FOLLOW UP
7 sec.
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOL
«1st VISIT» Mode
Simultaneous dual-arm measurements
Select «1st VISIT» Mode to complete a fullyautomated triple measurement on both arms
according to recommended ESH/AHA blood
pressure measurement protocols for a patient’s
first office visit.
In «1st VISIT» Mode, the WatchBP Office device
measures the patient’s blood pressure on both
arms simultaneously, helping to determine the
preferred measurement arm and reveal other
potential cardiovascular risks.
FOLLOW UP
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOLLOW UP
10
EN
Three operation modes (cont.)
Automated triple measurement
Determine proper measurement arm
In «1st VISIT» Mode, the WatchBP Office device
automatically takes three consecutive measurements
at one minute intervals by default. The result of these
three measurements are averaged to produce the
first visit blood pressure measurement.
If the measurement result between the two arm
differs more than 20mmHg for Systolic or 10mmHg
for Diastolic for all three measurements, the device
will indicate the higher measurement arm by a
flashing L or R.
60 sec.
60 sec.
* The user can manually set up the measurement
interval of 15, 30, 45 or 60 seconds in 1st Visit and
Follow-up Mode. (Please refer to special functions
section page.24 “Set up measurement interval”).
11
The higher arm should be used as the preferred
measurement arm for future measurements.
W UP
«FOLLOW-UP» Mode
Automated triple measurement
Select «FOLLOW-UP» Mode to complete a fullyautomated triple measurement on the preferred
measurement arm. According to recommended
ESH/AHA blood pressure measurement protocols for
follow-up blood pressure measurement.
In «FOLLOW-UP» Mode, the WatchBP Office
device automatically takes three consecutive
measurements at one minute intervals by default.
The result of these three measurements are
averaged to produce the follow-up visit blood
pressure measurement.
60 sec.
60 sec.
* The user can manually set up the measurement
AUSCULT 1st FOLLOW UP
interval of 15, 30, 45 or 60 seconds in 1st Visit and
Follow-up Mode. (Please refer to special functions
section page.24 “Set up measurement interval”).
12
EN
Taking measurements using WatchBP Office
«AUSCULTATION» Mode
1) Turn on the power – Turn on the device by
switching the I/O switch at the back of the
device into the ON position. and make sure
Bluetooth switch is in off position.
600mA
3) Switch to «AUSCULTATION» Mode – Slide the
Mode Switch to «AUSCULTATION» Mode.
DC 6V 600mA
AUSCULT 1st FOLLOW UP
2) Apply the cuff – Properly fit one cuff to the
preferred measurement arm.
AUSCULT 1st FO
4) Adjust inflation pressure if necessary –
Inflation pressure can be set manually from 140
to 280 mmHg by pressing and holding the Start/
Stop Button for 3 seconds.
Press the M Button to adjust the pressure and
press Start/Stop to save the setting.
* Additional visual instruction can be found on the cuff
13
5) Start inflation – Press the Start/Stop Button to
start inflation of the cuff.
Press and hold
for 3 seconds...
6) Take note – Take note of the systolic and
diastolic values in the same manner used for
sphygmomanometer measurements.
* The default inflation pressure is 180 mmHg.
* When the device is in standby mode, it will remind you
the current preset pressure setting by displaying the
current pressure setting on the screen.
7) Set device to Stand by Mode – The device can
be set to Stand by Mode by pressing the Start/
Stop Button. The device will automatically switch
to Idle Mode if left for five minutes.
Stand by mode
14
EN
Taking measurements using WatchBP Office (cont.)
«1st VISIT» Mode
1) Turn on the power – Turn on the device by
switching the I/O switch at the back of the device
to the ON position. and make sure Bluetooth
switch is in off position.
600mA
DC 6V 600mA
3) Switch to «1st VISIT» Mode – Slide the Mode
Switch to «1st VISIT» Mode.
AUSCULT 1st FOLLOW UP
2) Apply the cuff – Properly fit one cuff to each of
the patient’s arms.
AUSCULT 1st FOLLOW UP
AUSCULT 1st
4) Adjust inflation pressure if necessary –
Inflation pressure can be set manually from 140
to 280 mmHg by pressing and holding the Start/
Stop Button for 3 seconds.
Press the M Button to adjust the pressure and
press Start/Stop to save the setting.
* Additional visual instruction can be found on the cuff
15
Press and hold
for 3 seconds...
5) Start measurements – Press the Start/Stop
Button to start the measurement sequence.
* A 60-second countdown will proceed the first
measurement .
60-second
countdown...
* The default inflation pressure is 180 mmHg.
* The device will delate and re-pump more air into the cuff 6) Three consecutive measurements – The device
if the blood pressure of the patient is higher than that of
the inflation setting of the device.
* When the device is in standby mode, it will remind you
the current preset pressure setting by displaying the
current pressure setting on the screen.
will take three consecutive measurements with
one minute intervals in between measurements.
60
seconds
60
seconds
16
EN
Taking measurements using WatchBP Office (cont.)
7) View the average measurement – Only the
average measurement will be displayed once the
triplicate measurement is completed.
8) View all measurements – Results of the three
individual measurements can be accessed by
pressing the M Button. Press the M Button once to
review the first measurement. Continue to press
the M Button to review the other measurements.
* When the measurements are completed, the blood
pressure measurement corresponding with the
consistently higher arm will blink continuously for
5 seconds. If no significant difference (20mmHg for
systolic blood pressure or 10 mmHg for diastolic blood
pressure or both) exists between the two arms, neither
measurement will blink.
17
* WatchBP Office only stores the last three measurements
completed in «1st VISIT» and «FOLLOW-UP» Modes. To
store patient blood pressure for later retrieval, please use
the included WatchBP Office software.
«FOLLOW-UP» Mode
1) Turn on the power – Turn on the device by
switching the I/O switch at the back of the device
to the ON position and make sure Bluetooth
switch is in off position..
DC 6V 600mA
DC 6V 600mA
AUSCULT 1st FOLLOW UP
3) Switch to «FOLLOW-UP» Mode – Slide the Mode
Switch to «FOLLOW-UP» Mode.
AUSCULT 1st FOLLOW UP
2) Apply the cuff – Properly fit one cuff to the
preferred measurement arm.
AUSCULT 1st FOLLOW UP
4) Select the inflation cuff – Set the device to
inflate only the designated (right or left) cuff.
Press and hold the M Button for 3 seconds.
Press and hold
for 3 seconds...
* Additional visual instruction can be found on the cuff
18
EN
Taking measurements using WatchBP Office (cont.)
5) Press the M Button to toggle between the right(R)
and left(L) cuff. Press the Start/Stop Button to
save the setting.
6) Change inflation pressure – Inflation pressure
can be set manually from 140 to 280 mmHg by
pressing and holding the Start/Stop Button for
7 seconds.
Press M Button to adjust the pressure and press
Start/Stop again to save the setting.
19
Press and hold
for 7 seconds...
7) Start measurements – Press the Start/Stop
Button to start the measurement sequence.
60-second
countdown...
8) Three consecutive measurements – The device
will take three consecutive measurements with
one minute intervals in between measurements.
60
seconds
60
seconds
9) View the average measurement – Only the
average measurement will be displayed once the
triplicate measurement is completed.
10) View all measurements – Results of the three
individual measurements can be accessed by
pressing the M Button. Press the M Button once to
review the first measurement. Continue to press
the M Button to review the other measurements.
* WatchBP Office only stores the last three measurements
completed in «1st VISIT» and «FOLLOW-UP» Modes. To
store patient blood pressure for later retrieval, please
use the included WatchBP Office software.
20
EN
Special Functions
Hiding measurement values
The WatchBP Office device features a Hide function
in order to prevent unnecessary elevated blood
pressure in patients due to nervousness triggered by
visible blood pressure measurements.
* This feature is only available in follow up mode
1) Activate the «Hide» Function – pressing and
holding the M Button for 7 seconds.
Press and hold
for 7 seconds...
2) Select ON or OFF – Press the M Button again to
turn the “Hide” function ON or OFF.
* When the «Hide»
function is ON, the
countdown between
each measurement and
the Hide icon will be
displayed.
3) Confirm – Press Start/Stop to confirm the setting.
* Please make sure the
Bluetooth switch is in OFF
position, otherwise the
«Hide» function can not
be set.
21
* The «1st VISIT» Mode “Hide” default setting is set to ON
and cannot be set to OFF.
MAP (Mean Arterial Pressure)
PP (Pulse Pressure)
The WatchBP Office device measures the true
mean arterial pressured (MAP) of the patient. Each
measurement includes the calculation of a single
MAP value. The average measurement will display
the average MAP value. When viewing in Memory
mode, the MAP value will be displayed with the
systolic/diastolic pressure once every 5 seconds.
The WatchBP Office device measures the pulse
pressure (PP) of the patient: pulse pressure = systolic
- diastolic pressure. Each measurement includes
the calculation of a single PP value. The average
measurement will display the average PP value.
When viewing in Memory mode, the PP value will be
displayed with the systolic/diastolic pressure once
every 5 seconds.
22
EN
Special Function (cont.)
Taking fewer than three measurements
Skipping the 60-second countdown
In «FOLLOW-UP» Mode only, the measurement
sequence can be stopped at anytime by pushing
the Start/Stop Button. By pushing the Start/
Stop Button remaining the device enters standby, cancelling remaining measurements in the
sequence. Data from the measurements completed
can be by viewed by pushing the M Button.
In «1st VISIT» and «FOLLOW-UP» Mode, the
60-second pre-measurement countdown can be
skipped by pushing the Start/Stop Button. Once
the Start/Stop Button is pushed, the device will
immediately begin the next measurement.
Cancels remaining
measurements at
anytime during
the measurement
sequence.
Skips the 60-second
countdown and begins
measurement.
* The device can put into Stand by Mode by pressing
the Start/Stop Button after the completion of
measurements. The device will automatically switch to
Stand by Mode if left unattended for five minutes.
Stand by mode
23
Setting inflation pressure
Setting measurement intervals
Inflation pressure can be set manually from 140 to
280 mmHg by pressing and holding the Start/Stop
Button for 7 seconds.
It is concluded that a 15-second interval between
blood pressure readings and these measurements
are started after a 5 minute rest period.
Press and hold
for 7 seconds...
Press the M Button to adjust the pressure and press
Start/Stop again to save the setting.
1) Pressing and holding the Start/Stop Button for 3
seconds.
Press and hold
for 3 seconds...
2) Press the M Button to adjust the measurement
interval, then press the Start/Stop Button to
confirm, the meter will back to stand by Mode.
15 30
45 60
24
EN
Viewing Measurements
«AUSCULTATION» Mode
«1st VISIT» and «FOLLOW-UP» Mode
The WatchBP Office blood pressure measurement
device in «AUSCULTATION» mode serves only as a
pressure gauge. No oscillometric measurements will
be taken and a mental note must be made of the
systolic and diastolic values.
1) Switch the mode switch –The M Button can be
pressed in either «1st VISIT» or the «FOLLOWUP» mode to retrieve the last set of the triplicate
measurements.
AUSCULT 1st FOLLOW UP
Memory
25
AUSCULT 1st FOLLOW UP
AUSCULT 1st FOLLOW UP
2) Viewing the average of all measurements –
At first an “A” will be displayed, followed by an
average of all measurements taken in the last
sequence of measurements.
3) Viewing MAP and PP values –
Ten seconds after the display of the average
blood pressure, the device will display values for
Pulse Pressure (PP) and Mean Arterial Pressure
(MAP).
5) Values for the third measurement (including PP
and MAP values) will be shown on the display
in the order listed in step 3.
10
seconds...
4) Viewing individual measurements – Press
the M Button once again to view individual
measurements. The display will flash a number
“3” indicating the third measurement.
10
seconds...
6) Press the M Button to retrieve values for second
and first measurements from the last completed
set of measurements.
26
EN
Controlling the WatchBP Office wirelessly
The WatchBP Office can be controlled wirelessly via
Bluetooth with the included WatchBP Office software.
Please follow the steps listed here to set up a wireless
connection with a computer.
Setting up the Bluetooth receiver
1) Place the included “Bluetooth USB Adaptor” CD
in the CD-ROM of the computer. Click on «setup.
exe» in the CD-ROM directory.
2) An installation window will appear. Follow the
instructions on the screen.
AU SC
ULT
LLO
1st FO
W UP
IN
R VA
SU
ES
P R c.
se
TE
RE
Before installing the WatchBP Office software, the
driver software for the Bluetooth receiver must be first
installed on the computer.
* The distance between WatchBP office and operating
computer should be within 10m.
27
Bluetooth Receiver
Driver
Install CD
Instruction
3) Insert the Bluetooth receiver into a USB port
of the computer after the installation program
requests to do so.
4) Restart the computer after installation is
completed.
5) Turn on the Bluetooth function of the WatchBP
Office device on by switching the Bluetooth
switch at the back of the device to the “ON”
position. The Bluetooth icon will illuminate and
flash continuously to show a connection.
* Select a single USB port and make sure to always use
the same port in the future.
* Do not use other Bluetooth receiver.
Restart
your
computer
It is noted that WatchBP office device will not
respond to any button pressing or switching when
the Bluetooth is on. It is to prevent accidental
interruptions during the measurement.
DC 6V 600mA
DC
28
EN
Controlling the WatchBP Office wirelessly (cont.)
Installation of the software program
Controlling the device wirelessly
1) Put the CD in the CD-ROM drive of your computer.
Then click on «setup.exe» in the CD’s directory.
1) Turn on the Bluetooth switch located on the back
of the device.
2) Follow the instructions provided in the
installation window on the computer screen.
2) Make sure the Bluetooth receiver is at right
position and the light is on (if applicable).
3) When the installation is complete, be sure restart
the computer before using the program for the
first time.
3) Launch WatchBP Office Software from the
computer. Follow these steps to control the
WatchBP Office from the computer.
WatchBP Analyzer Office
Version 1.0.2.4
Install CD
System Requirements: 550MHz CPU. 256MB Memory, 1024x768
pixel resolution, 256 color, CD-ROM drive, 1 free USB port, 40MB
free hard disk space, Microsoft Windows 2000 / XP / Vista.
29
ed.
serv
©200
s Re
Right
8 Microlif
e Corporation. All
* System Requirements:
550MHz CPU. 256MB
Memory, 1024x768 pixel
resolution, 256 color,
CD-ROM drive, 1 free USB
port, 40MB free hard disk
space, Microsoft Windows
2000 / XP / Vista.
DC 6V 600mA
Software commands
Choose measure blood pressure
Click «1st VISIT», «FOLLOW-UP»
Enter Patient ID
Input Patient ID
Start to perform
Press the «Measure» button
Store blood pressure measurements Click «Save». The data is stored in an Excel data table. The file
name is generated automatically from the following format
«Patient ID+ WatchBP Office +measurement mode +
yyyymmdd.xls».
View the data
Go to the folder where the file is saved and open the
corresponding excel file.
Print the data sheet
While the corresponding Excel file is open, click print in Excel.
Disconnect the device
Click <> before existing the program
Close the program
Click «Close»
* The software automatically searches for the nearest WatchBP device when the program is launched. If the device is
not located, confirm that the Bluetooth switch on the WatchBP Office is set to the ON position.
30
EN
Rechargeable battery and power adaptor
Rechargeable Battery
Using a power adaptor
WatchBP Office features a built-in, rechargeable
Ni-MH battery pack that delivers up to 400~500
measurement cycles. The battery can be recharged
between use with the provided power adaptor.
Please use only the Microlife adaptor (DSA-20P-05
Adaptor) supplied with the WatchBP Office to
recharge the device.
1) Plug the adapter cable into the Power Plug in the
WatchBP Office device.
2) Plug the adaptor plug into the wall socket. When
the power adaptor is connected, no battery
power is consumed.
S YS
mmHg
DIA
mmHg
* An orange recharge
indicator means recharge
in progress.
DC 6V 600mA
SYS
mmHg
DIA
mmHg
31
* A green recharge
indicator means recharge
is completed.
DC 6V 600mA
Troubleshooting
Problem
Possible cause
How to make correction
No power(No LCD display) Power supply is not
Plug power supply into wall socket.
properly plugged
Battery is fully discharged Recharge the rechargeable battery by plugging in
the power supply.
Cuff does not inflate
Loose connection of the
Make sure the tube of the cuff is securely
properly
tube
connected to the device.
Leakage of the tube /
Check for cracks on the tube or the bladder. Please
bladder
contact Microlife customer service for this issue.
Hide, pressure, or pause Wireless option is ON
The device can not be operated by the Start/Stop
interval can not be set
and M Button when the Bluetooth switch is in thev
ON position. Please switch off the Bluetooth or use
Unable to take
the included software to control the device.
measurement
No result displayed
between measurements
Can’t access device via
computer
Device is in AUSCULTATION
mode or the Hide function
is activated
Bluetooth software not
installed
Disable “hide” function, or use «1st VISIT» /
«FOLLOW-UP» mode to measure the blood
pressure.
Make sure the Bluetooth software provided with
the device is installed on the computer.
32
EN
Error messages
If an error occurs during measurement, the
measurement is interrupted and an error
message «Err» is displayed.
• Please contact your local
Microlife service center if
the error persists.
• If you think the results
are unusual, please read
through the information
in this instruction manual
carefully.
33
Error
Description
Potential cause and
remedy
«Err 1»
Signal too
weak
The pulse signals
on the cuff are too
weak. Re-position the
cuff and repeat the
measurement.
«Err 2»
Error signal
During the
measurement,
error signals were
detected by the cuff,
caused for instance by
movement or muscle
tension. Repeat the
measurement, keeping
your arm still.
«Err 3»
No pressure
in the cuff
An adequate pressure
cannot be generated
in the cuff. A leak
may have occurred.
Replace the batteries if
necessary. Repeat the
measurement.
«Err 5»
Abnormal
result
The measuring signals
are inaccurate and no
result can therefore
be displayed. Read
through the checklist
for performing reliable
measurements and
then repeat the
measurement.
«HI»
Pulse or cuff
pressure too
high
The pressure in the
cuff is too high (over
300 mmHg) OR the
pulse is too high
(over 200 beats per
minute). Relax for 5
minutes and repeat the
measurement.
«LO»
Pulse too
low
The pulse is too low
(less than 40 beats per
minute). Repeat the
measurement.
34
EN
Safety, care, accuracy test and disposal
Safety and protection
This device may be used only for the purpose
described in this booklet. The device comprises of
sensitive components and must be treated with
caution. The manufacturer cannot be held liable for
damage caused by incorrect application.
• Ensure that children do not use the device
unsupervised; some parts are small enough to be
swallowed.
Observe the storage and operating conditions
described in the “Technical specifications” section
of this manual.
Protect the device from water and moisture
Protect the device from direct sunlight
Protect the device from extreme heat and cold
•
• Do not use the device if you think it is damaged or
Avoid proximity to electromagnetic fields, such
as those produced by mobile phones
• Read the further safety instructions in the
Never open device
• Do not connect the device to a computer
Protect device from impact and drops
Only activate the pump when cuff is installed.
if anything appears unusual.
individual sections of the instruction manual.
until prompted to do so by the computer software.
35
Device care
Cleaning the cuff
Clean the device with a soft, dry cloth.
DO NOT wash the cuff. DO NOT iron the cuff cover.
Do not wash the cuff!
AU SC
ULT
LLO
1st FO
W UP
IN
Do not iron the cuff!
R VA
SU
ES
P R c.
se
TE
RE
Accuracy test
Disposal
We recommend the WatchBP Office device
be tested for accuracy every 2 years or after
mechanical impact (e.g. being dropped). Please
contact Microlife to arrange for an accuracy test.
Batteries and electronic instruments must be
disposed of in accordance with the locally applicable
regulations, and not as domestic waste.
36
EN
Technical specifications
Operation
temperature/humidity: 10 - 40 °C / 50 - 104 °F
Storage temperature/
humidity:
Weight:
•
• -20 - +50 °C / -4 - +122 °F
• 15 - 90 % relative maximum humidity
• 1100 g (including rechargeable
•
• IEC60601-1 General requirement for
Reference to Standards: EN 1060-1 /-3, NIBP-requirements
safety
• IEC60601-1-2 Requirements for EMC
• EN1060-4, NIBP clinical investigation
• ANSI/AAMI SP10, NIBP requirements
• Bluetooth system to V2.0
• FCC part15C
battery pack)
Dimensions:
Measuring method:
• 200 x 125 x 90 mm
• Oscillometric, corresponding to
Korotkoff
Measurement range:
Cuff pressure display:
• 30 - 280 mmHg – blood pressure
• 40 - 200 beats per minute – pulse
• Range: 0 - 299 mmHg
• Resolution: 1 mmHg
• Static accuracy: pressure within ±3
Federal Communications Commission (FCC) Statement
15.21
You are cautioned that changes or modifications not expressly
approved by the part responsible for compliance could void the
user’s authority to operate the equipment.
mmHg
• Pulse accuracy: ±5 % of the readout
value
Voltage source:
• Rechargeable battery pack;
4.8V C4000 mAh
• Mains adapter DC 7.5V, 2 A
37
5.105(b)
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
that may cause undesired operation of the device.
generates, uses and can radiate radio frequency energy and, if
FCC RF Radiation Exposure Statement:
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the
This equipment complies with FCC radiation exposure limits set forth
for an uncontrolled environment. End users must follow the specific
operating instructions for satisfying RF exposure compliance. This
transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Operation is subject to the following two conditions:
1) this device may not cause interference and
2) this device must accept any interference, including interference
38
EN
Guarantee card
This device is covered by a two-year
guarantee and accessories are cover by
a one-year guarantee from the date of
Name:
Address:
purchase. This guarantee is valid only
on presentation of the guarantee card
Date:
completed by the owner confirming date of
Telephone:
purchase or purchase receipt.
Product: WatchBP Office
Product Number: Twin200
Date:
Email:
Europe / Middle-East / Africa
Asia
North / Central / South America
Microlife WatchBP AG
Espenstrasse 139
9443 Widnau, Switzerland
Tel +41 71 727 7000
Fax +41 71 727 7011
Email: watchbp@microlife.ch
www.watchbp.com
Microlife Corporation
9F, 431, RuiGang Road, NeiHu
Taipei, 114, Taiwan, R.O.C.
Tel +886 2 8797 1288
Fax+886 2 8797 1283
Email: watchbp@microlife.com.tw
www.watchbp.com
Microlife Medical Home Solutions, Inc.
2801 Youngfield St., Suite 241
Golden, CO 80401, USA
Tel +1 303 274 2277
Fax +1 303 274 2244
Email: watchbp@mimhs.com
www.watchbp.com
IB WatchBP Office 2508

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Create Date                     : 2008:06:30 11:44:58+08:00
Modify Date                     : 2008:06:30 11:45:12+08:00
Metadata Date                   : 2008:06:30 11:45:12+08:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9979 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:99aefe3f-0755-704e-a9a7-037af7bbafb0
Document ID                     : adobe:docid:indd:983ca822-3eb8-11dd-9347-e67b872d54ed
Rendition Class                 : proof:pdf
Derived From Instance ID        : 983ca821-3eb8-11dd-9347-e67b872d54ed
Derived From Document ID        : adobe:docid:indd:ccdc659f-3582-11dd-9ae5-d6956278dd3b
Derived From Version ID         : 1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:40B3BB8D2E9611DDAFF3E1C72CE0D0D4, uuid:511ef49e-fbb4-481d-a03b-7bec53aca300, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:85add730-14bf-4f55-a689-848bdcd12bbf, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:6e50005f-8828-42f5-ad26-52b742bdd9a7, uuid:ed05fce7-2b35-41b4-9f1c-75af2e780cec, uuid:c7ff1e4d-a688-40bb-9bd8-0988f4b2bce9, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:54b304e9-450f-4c1c-b245-7f1f0a8ebbb6, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:b0ade4a5-f631-41c8-85fb-cd4eeec99262, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:3d609a8b-603b-46f8-b0a6-eb5ca8d91dfe, uuid:9c0c8f85-1da3-4791-83bd-3854d274aea0, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:ed05fce7-2b35-41b4-9f1c-75af2e780cec, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:3d609a8b-603b-46f8-b0a6-eb5ca8d91dfe, uuid:5e5aa24a-5361-4b23-be92-0e4485643746, uuid:84f5086b-66a3-4776-9f1d-1625549e5d9c
Manifest Reference Document ID  : uuid:B03ED04D24CE11DDA93CF3AF1A50FB54, uuid:4A873A30233F11DD8EE8DD8F8CE47694, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:A569BE51233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE4D233E11DD8EE8DD8F8CE47694, uuid:A04A1E7824D311DDB87EBDAFA93FA33C, uuid:3F19B96A235011DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:E2D92C792E8D11DDBD27EF4371DBD84E, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:50451AF624D911DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0224ED11DD9EE2ED0C9DBE8A73, uuid:2B17E591274B11DD8559C844805CA816, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A04A1E7824D311DDB87EBDAFA93FA33C, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0224ED11DD9EE2ED0C9DBE8A73, uuid:E46A156C24E911DD9EE2ED0C9DBE8A73, uuid:4A873A33233F11DD8EE8DD8F8CE47694
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 41