Microlife TWIN200-1 WatchBP Professional User Manual
Microlife Corporation WatchBP Professional
User Manual
Simultaneous dual-arm measurement and auscultatory function for accurate office blood pressure measurement. Instruction Manual EN WatchBP Office combines the advantages of an automatic blood pressure device and hybrid sphygmomanometer and is designed to provide convenient, accurate and reliable in-office blood pressure measurement following recommended guidelines of the European Society of Hypertension (ESH) 1, American Heart Association (AHA), and World Health Organization (WHO). O’Brien E, Asmar R, Beilin L, Imai Y, et al. European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement. European Society of Hypertension Working Group on Blood Pressure Deviceing. J Hypertens 2003;21:821-848. Table of Contents Product description Name of parts and display.................................. 3–4 Components and accessories.............................. 5–6 Before using WatchBP Office Selecting and fitting the correct cuff................... 7–8 Three operation modes «AUSCULTATION» Mode........................................... 9 «1st VISIT» Mode............................................. 10–11 «FOLLOW-UP» Mode.............................................. 12 Taking measurements using WatchBP Office «AUSCULTATION» Mode................................... 13–14 «1st VISIT» Mode............................................. 15–17 «FOLLOW-UP» Mode........................................ 18–20 Special Functions Hiding measurement values................................. 21 Mean arterial pressure and pulse pressure .......... 22 Taking fewer than three measurements ............. 23 Skipping the 60-second countdown..................... 23 Setting inflation pressure...................................... 24 Setting measurement intervals............................ 24 Viewing Measurements «AUSCULTATION» Mode ........................................ 25 «1st VISIT» and «FOLLOW-UP» Mode.............. 25–26 Controlling the WatchBP Office Wirelessly Setting up the Bluetooth receiver................... 27–28 Installation of the software program.................... 29 Controlling the device wirelessly ................... 29–30 Appendix Rechargeable battery and power adaptor . ......... 31 Troubleshooting.................................................... 32 Error messages................................................ 33–34 Safety, care, accuracy test and disposal.......... 35–36 Technical specifications........................................ 37 EN Product description Name of parts I/O switch Bluetooth Switch Main Adaptor Socket Battery Compartment Cuff Socket (R) DC 6V 600mA DC 6V 600mA Cuff Socket (L) SYS mmHg DIA mmHg Recharge Indicator Display M Button (Memory) SYS mmHg DIA mmHg PUL /min Mode Switch I N T E R VA L Start/Stop Button 3 sec. L/R 3 sec. HIDE 7 sec. 7 sec. AUSCULT 1st FOLLOW UP Display Mean Arterial Pressure (MAP) Pulse Pressure (PP) Mode Indication External Power Value for Left Arm Systolic Value Diastolic Value Bluetooth Rest and Arm Position Reminder Battery Symbol Hide Display Memory Mode Pulse Rate Value for Right Arm Systolic Value Diastolic Value Heart Beat L/R Cuff EN WatchBP Office and components Bluetooth Receiver Driver SYS g mmH DIA mmHg Install CD SYS g mmH DIA mmHg PUL /min AUSC ULT 1st FOLLO UP WatchBP Office blood pressure device (1 pcs.) AC Adaptor X1 (Input: 100-240V~50/60Hz 0.7A Output: +7.5V 2A) Bluetooth receiver X1 Install CD X1 Quick start guide How to take blood presssure measurement in three different modes 1 Plug cuff connector «1st VISIT» Mode (Double arm) ght All R «AUSCULTATION» Mode (Single arm) Flip over the quick start guide to see ‘Product description’. 68 y, 1024x7 Memor port, 40MB z CPU. 256MB free USB s: 550MH drive, 1 ement Vista. Requir / XP / color, CD-ROM System s 2000 ion, 256 ft Window pixel resolut space, Microso disk free hard WatchBP Office Software CD X1 Simultaneous dual-arm Press Start/Stop button to begin a measurement and measurement Note bloodfor auscultatory function presure using accurate in-officeauscultatory blood method pressure measurement. Place the stethoscope on the hollow of the elbow, over the brachial artery 3 Switch the mode Install CD An averaged result will be displayed after three consecutive measurments Press Start/Stop button to begin a measurement «FOLLOW-UP» Mode (Single arm) 2 Turn on the device ration 1.0.2 Version ©2008 Microlife Corpo Office d. rve ese sR in the cuff socket Analyzer WatchBP .4 Instruction Manual EN M size (22cm~32cm) X2 L size (32cm~42cm) X2 Manual Instruction X1 Quick Start Guide X1 Selective Cuffs M (Medium size) 22 - 32 cm (8.75 - 12.5 inches) With air tube 130 cm L (Large size) 32-42 cm (12.5-16.5 inches) With air tube 130 cm * Please contact Microlife or its distributor to purchase cuffs. EN Before using WatchBP Office Selecting the correct cuff Fitting the cuff properly Two different cuff sizes are provided with the WatchBP Office: Medium and Large. Select the cuff size that best matches the circumference of the patient’s upper arm. 1) Place the cuff over the left (right) upper arm so that the air tube and artery mark arrow point toward the lower arm. M (Medium size) 22 - 32 cm (8.75 - 12.5 inches) 2) Lay the cuff on the arm. Make sure that the lower edge of the cuff lies approximately ¾” to 1”(2 to 3cm) above the elbow. M is the correct size for most people. L (Large size) 32-42 cm (12.5-16.5 inches) Connect the cuff to the device by inserting the cuff connector into the cuff connector socket. 2–3cm 3) Wrap and tighten the cuff around the arm. 4) Leave a little free space between the arm and the cuff. The patient should be able to fit 2 fingers between the arm and the cuff. Clothing must not restrict the arm. Remove all clothing covering or constricting the measurement arm. 5) Cuffs that do not fit properly can result in incorrect blood pressure measurements. Use a different size cuff if the range Index at the end of the cuff does not fall into the range specified by the range stripes. 6) Apply the same steps to the other arm if a double arm measurement is required. * The range index of cuff should be fallen into this range. EN Three operation modes SY S Choose a desired operationmmHg mode «AUSCULTATION» Mode DIA The WatchBP Office device includesmmHg three convenient operation modes: «AUSCULTATION», «1st VISIT» and «FOLLOW-UP» Mode.Use the ModeSYSwitch on the mmHg side of the device to select the desired mode. Select «AUSCULTATION» Mode for blood pressure measurement of patients with arrhythmia, and, if needed, to confirm if a patient is suitable for the oscillometric method using a digital blood pressure monitor. DIA mmHg PUL /min I N T E R VA L 3 sec. L/R 3 sec. HIDE 7 sec. 1st FOLLOW UP 7 sec. AUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP AUSCULT 1st FOL «1st VISIT» Mode Simultaneous dual-arm measurements Select «1st VISIT» Mode to complete a fullyautomated triple measurement on both arms according to recommended ESH/AHA blood pressure measurement protocols for a patient’s first office visit. In «1st VISIT» Mode, the WatchBP Office device measures the patient’s blood pressure on both arms simultaneously, helping to determine the preferred measurement arm and reveal other potential cardiovascular risks. FOLLOW UP AUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP 10 EN Three operation modes (cont.) Automated triple measurement Determine proper measurement arm In «1st VISIT» Mode, the WatchBP Office device automatically takes three consecutive measurements at one minute intervals by default. The result of these three measurements are averaged to produce the first visit blood pressure measurement. If the measurement result between the two arm differs more than 20mmHg for Systolic or 10mmHg for Diastolic for all three measurements, the device will indicate the higher measurement arm by a flashing L or R. 60 sec. 60 sec. * The user can manually set up the measurement interval of 15, 30, 45 or 60 seconds in 1st Visit and Follow-up Mode. (Please refer to special functions section page.24 “Set up measurement interval”). 11 The higher arm should be used as the preferred measurement arm for future measurements. W UP «FOLLOW-UP» Mode Automated triple measurement Select «FOLLOW-UP» Mode to complete a fullyautomated triple measurement on the preferred measurement arm. According to recommended ESH/AHA blood pressure measurement protocols for follow-up blood pressure measurement. In «FOLLOW-UP» Mode, the WatchBP Office device automatically takes three consecutive measurements at one minute intervals by default. The result of these three measurements are averaged to produce the follow-up visit blood pressure measurement. 60 sec. 60 sec. * The user can manually set up the measurement AUSCULT 1st FOLLOW UP interval of 15, 30, 45 or 60 seconds in 1st Visit and Follow-up Mode. (Please refer to special functions section page.24 “Set up measurement interval”). 12 EN Taking measurements using WatchBP Office «AUSCULTATION» Mode 1) Turn on the power – Turn on the device by switching the I/O switch at the back of the device into the ON position. and make sure Bluetooth switch is in off position. 600mA 3) Switch to «AUSCULTATION» Mode – Slide the Mode Switch to «AUSCULTATION» Mode. DC 6V 600mA AUSCULT 1st FOLLOW UP 2) Apply the cuff – Properly fit one cuff to the preferred measurement arm. AUSCULT 1st FO 4) Adjust inflation pressure if necessary – Inflation pressure can be set manually from 140 to 280 mmHg by pressing and holding the Start/ Stop Button for 3 seconds. Press the M Button to adjust the pressure and press Start/Stop to save the setting. * Additional visual instruction can be found on the cuff 13 5) Start inflation – Press the Start/Stop Button to start inflation of the cuff. Press and hold for 3 seconds... 6) Take note – Take note of the systolic and diastolic values in the same manner used for sphygmomanometer measurements. * The default inflation pressure is 180 mmHg. * When the device is in standby mode, it will remind you the current preset pressure setting by displaying the current pressure setting on the screen. 7) Set device to Stand by Mode – The device can be set to Stand by Mode by pressing the Start/ Stop Button. The device will automatically switch to Idle Mode if left for five minutes. Stand by mode 14 EN Taking measurements using WatchBP Office (cont.) «1st VISIT» Mode 1) Turn on the power – Turn on the device by switching the I/O switch at the back of the device to the ON position. and make sure Bluetooth switch is in off position. 600mA DC 6V 600mA 3) Switch to «1st VISIT» Mode – Slide the Mode Switch to «1st VISIT» Mode. AUSCULT 1st FOLLOW UP 2) Apply the cuff – Properly fit one cuff to each of the patient’s arms. AUSCULT 1st FOLLOW UP AUSCULT 1st 4) Adjust inflation pressure if necessary – Inflation pressure can be set manually from 140 to 280 mmHg by pressing and holding the Start/ Stop Button for 3 seconds. Press the M Button to adjust the pressure and press Start/Stop to save the setting. * Additional visual instruction can be found on the cuff 15 Press and hold for 3 seconds... 5) Start measurements – Press the Start/Stop Button to start the measurement sequence. * A 60-second countdown will proceed the first measurement . 60-second countdown... * The default inflation pressure is 180 mmHg. * The device will delate and re-pump more air into the cuff 6) Three consecutive measurements – The device if the blood pressure of the patient is higher than that of the inflation setting of the device. * When the device is in standby mode, it will remind you the current preset pressure setting by displaying the current pressure setting on the screen. will take three consecutive measurements with one minute intervals in between measurements. 60 seconds 60 seconds 16 EN Taking measurements using WatchBP Office (cont.) 7) View the average measurement – Only the average measurement will be displayed once the triplicate measurement is completed. 8) View all measurements – Results of the three individual measurements can be accessed by pressing the M Button. Press the M Button once to review the first measurement. Continue to press the M Button to review the other measurements. * When the measurements are completed, the blood pressure measurement corresponding with the consistently higher arm will blink continuously for 5 seconds. If no significant difference (20mmHg for systolic blood pressure or 10 mmHg for diastolic blood pressure or both) exists between the two arms, neither measurement will blink. 17 * WatchBP Office only stores the last three measurements completed in «1st VISIT» and «FOLLOW-UP» Modes. To store patient blood pressure for later retrieval, please use the included WatchBP Office software. «FOLLOW-UP» Mode 1) Turn on the power – Turn on the device by switching the I/O switch at the back of the device to the ON position and make sure Bluetooth switch is in off position.. DC 6V 600mA DC 6V 600mA AUSCULT 1st FOLLOW UP 3) Switch to «FOLLOW-UP» Mode – Slide the Mode Switch to «FOLLOW-UP» Mode. AUSCULT 1st FOLLOW UP 2) Apply the cuff – Properly fit one cuff to the preferred measurement arm. AUSCULT 1st FOLLOW UP 4) Select the inflation cuff – Set the device to inflate only the designated (right or left) cuff. Press and hold the M Button for 3 seconds. Press and hold for 3 seconds... * Additional visual instruction can be found on the cuff 18 EN Taking measurements using WatchBP Office (cont.) 5) Press the M Button to toggle between the right(R) and left(L) cuff. Press the Start/Stop Button to save the setting. 6) Change inflation pressure – Inflation pressure can be set manually from 140 to 280 mmHg by pressing and holding the Start/Stop Button for 7 seconds. Press M Button to adjust the pressure and press Start/Stop again to save the setting. 19 Press and hold for 7 seconds... 7) Start measurements – Press the Start/Stop Button to start the measurement sequence. 60-second countdown... 8) Three consecutive measurements – The device will take three consecutive measurements with one minute intervals in between measurements. 60 seconds 60 seconds 9) View the average measurement – Only the average measurement will be displayed once the triplicate measurement is completed. 10) View all measurements – Results of the three individual measurements can be accessed by pressing the M Button. Press the M Button once to review the first measurement. Continue to press the M Button to review the other measurements. * WatchBP Office only stores the last three measurements completed in «1st VISIT» and «FOLLOW-UP» Modes. To store patient blood pressure for later retrieval, please use the included WatchBP Office software. 20 EN Special Functions Hiding measurement values The WatchBP Office device features a Hide function in order to prevent unnecessary elevated blood pressure in patients due to nervousness triggered by visible blood pressure measurements. * This feature is only available in follow up mode 1) Activate the «Hide» Function – pressing and holding the M Button for 7 seconds. Press and hold for 7 seconds... 2) Select ON or OFF – Press the M Button again to turn the “Hide” function ON or OFF. * When the «Hide» function is ON, the countdown between each measurement and the Hide icon will be displayed. 3) Confirm – Press Start/Stop to confirm the setting. * Please make sure the Bluetooth switch is in OFF position, otherwise the «Hide» function can not be set. 21 * The «1st VISIT» Mode “Hide” default setting is set to ON and cannot be set to OFF. MAP (Mean Arterial Pressure) PP (Pulse Pressure) The WatchBP Office device measures the true mean arterial pressured (MAP) of the patient. Each measurement includes the calculation of a single MAP value. The average measurement will display the average MAP value. When viewing in Memory mode, the MAP value will be displayed with the systolic/diastolic pressure once every 5 seconds. The WatchBP Office device measures the pulse pressure (PP) of the patient: pulse pressure = systolic - diastolic pressure. Each measurement includes the calculation of a single PP value. The average measurement will display the average PP value. When viewing in Memory mode, the PP value will be displayed with the systolic/diastolic pressure once every 5 seconds. 22 EN Special Function (cont.) Taking fewer than three measurements Skipping the 60-second countdown In «FOLLOW-UP» Mode only, the measurement sequence can be stopped at anytime by pushing the Start/Stop Button. By pushing the Start/ Stop Button remaining the device enters standby, cancelling remaining measurements in the sequence. Data from the measurements completed can be by viewed by pushing the M Button. In «1st VISIT» and «FOLLOW-UP» Mode, the 60-second pre-measurement countdown can be skipped by pushing the Start/Stop Button. Once the Start/Stop Button is pushed, the device will immediately begin the next measurement. Cancels remaining measurements at anytime during the measurement sequence. Skips the 60-second countdown and begins measurement. * The device can put into Stand by Mode by pressing the Start/Stop Button after the completion of measurements. The device will automatically switch to Stand by Mode if left unattended for five minutes. Stand by mode 23 Setting inflation pressure Setting measurement intervals Inflation pressure can be set manually from 140 to 280 mmHg by pressing and holding the Start/Stop Button for 7 seconds. It is concluded that a 15-second interval between blood pressure readings and these measurements are started after a 5 minute rest period. Press and hold for 7 seconds... Press the M Button to adjust the pressure and press Start/Stop again to save the setting. 1) Pressing and holding the Start/Stop Button for 3 seconds. Press and hold for 3 seconds... 2) Press the M Button to adjust the measurement interval, then press the Start/Stop Button to confirm, the meter will back to stand by Mode. 15 30 45 60 24 EN Viewing Measurements «AUSCULTATION» Mode «1st VISIT» and «FOLLOW-UP» Mode The WatchBP Office blood pressure measurement device in «AUSCULTATION» mode serves only as a pressure gauge. No oscillometric measurements will be taken and a mental note must be made of the systolic and diastolic values. 1) Switch the mode switch –The M Button can be pressed in either «1st VISIT» or the «FOLLOWUP» mode to retrieve the last set of the triplicate measurements. AUSCULT 1st FOLLOW UP Memory 25 AUSCULT 1st FOLLOW UP AUSCULT 1st FOLLOW UP 2) Viewing the average of all measurements – At first an “A” will be displayed, followed by an average of all measurements taken in the last sequence of measurements. 3) Viewing MAP and PP values – Ten seconds after the display of the average blood pressure, the device will display values for Pulse Pressure (PP) and Mean Arterial Pressure (MAP). 5) Values for the third measurement (including PP and MAP values) will be shown on the display in the order listed in step 3. 10 seconds... 4) Viewing individual measurements – Press the M Button once again to view individual measurements. The display will flash a number “3” indicating the third measurement. 10 seconds... 6) Press the M Button to retrieve values for second and first measurements from the last completed set of measurements. 26 EN Controlling the WatchBP Office wirelessly The WatchBP Office can be controlled wirelessly via Bluetooth with the included WatchBP Office software. Please follow the steps listed here to set up a wireless connection with a computer. Setting up the Bluetooth receiver 1) Place the included “Bluetooth USB Adaptor” CD in the CD-ROM of the computer. Click on «setup. exe» in the CD-ROM directory. 2) An installation window will appear. Follow the instructions on the screen. AU SC ULT LLO 1st FO W UP IN R VA SU ES P R c. se TE RE Before installing the WatchBP Office software, the driver software for the Bluetooth receiver must be first installed on the computer. * The distance between WatchBP office and operating computer should be within 10m. 27 Bluetooth Receiver Driver Install CD Instruction 3) Insert the Bluetooth receiver into a USB port of the computer after the installation program requests to do so. 4) Restart the computer after installation is completed. 5) Turn on the Bluetooth function of the WatchBP Office device on by switching the Bluetooth switch at the back of the device to the “ON” position. The Bluetooth icon will illuminate and flash continuously to show a connection. * Select a single USB port and make sure to always use the same port in the future. * Do not use other Bluetooth receiver. Restart your computer It is noted that WatchBP office device will not respond to any button pressing or switching when the Bluetooth is on. It is to prevent accidental interruptions during the measurement. DC 6V 600mA DC 28 EN Controlling the WatchBP Office wirelessly (cont.) Installation of the software program Controlling the device wirelessly 1) Put the CD in the CD-ROM drive of your computer. Then click on «setup.exe» in the CD’s directory. 1) Turn on the Bluetooth switch located on the back of the device. 2) Follow the instructions provided in the installation window on the computer screen. 2) Make sure the Bluetooth receiver is at right position and the light is on (if applicable). 3) When the installation is complete, be sure restart the computer before using the program for the first time. 3) Launch WatchBP Office Software from the computer. Follow these steps to control the WatchBP Office from the computer. WatchBP Analyzer Office Version 1.0.2.4 Install CD System Requirements: 550MHz CPU. 256MB Memory, 1024x768 pixel resolution, 256 color, CD-ROM drive, 1 free USB port, 40MB free hard disk space, Microsoft Windows 2000 / XP / Vista. 29 ed. serv ©200 s Re Right 8 Microlif e Corporation. All * System Requirements: 550MHz CPU. 256MB Memory, 1024x768 pixel resolution, 256 color, CD-ROM drive, 1 free USB port, 40MB free hard disk space, Microsoft Windows 2000 / XP / Vista. DC 6V 600mA Software commands Choose measure blood pressure Click «1st VISIT», «FOLLOW-UP» Enter Patient ID Input Patient ID Start to perform Press the «Measure» button Store blood pressure measurements Click «Save». The data is stored in an Excel data table. The file name is generated automatically from the following format «Patient ID+ WatchBP Office +measurement mode + yyyymmdd.xls». View the data Go to the folder where the file is saved and open the corresponding excel file. Print the data sheet While the corresponding Excel file is open, click print in Excel. Disconnect the device Click <> before existing the program Close the program Click «Close» * The software automatically searches for the nearest WatchBP device when the program is launched. If the device is not located, confirm that the Bluetooth switch on the WatchBP Office is set to the ON position. 30 EN Rechargeable battery and power adaptor Rechargeable Battery Using a power adaptor WatchBP Office features a built-in, rechargeable Ni-MH battery pack that delivers up to 400~500 measurement cycles. The battery can be recharged between use with the provided power adaptor. Please use only the Microlife adaptor (DSA-20P-05 Adaptor) supplied with the WatchBP Office to recharge the device. 1) Plug the adapter cable into the Power Plug in the WatchBP Office device. 2) Plug the adaptor plug into the wall socket. When the power adaptor is connected, no battery power is consumed. S YS mmHg DIA mmHg * An orange recharge indicator means recharge in progress. DC 6V 600mA SYS mmHg DIA mmHg 31 * A green recharge indicator means recharge is completed. DC 6V 600mA Troubleshooting Problem Possible cause How to make correction No power(No LCD display) Power supply is not Plug power supply into wall socket. properly plugged Battery is fully discharged Recharge the rechargeable battery by plugging in the power supply. Cuff does not inflate Loose connection of the Make sure the tube of the cuff is securely properly tube connected to the device. Leakage of the tube / Check for cracks on the tube or the bladder. Please bladder contact Microlife customer service for this issue. Hide, pressure, or pause Wireless option is ON The device can not be operated by the Start/Stop interval can not be set and M Button when the Bluetooth switch is in thev ON position. Please switch off the Bluetooth or use Unable to take the included software to control the device. measurement No result displayed between measurements Can’t access device via computer Device is in AUSCULTATION mode or the Hide function is activated Bluetooth software not installed Disable “hide” function, or use «1st VISIT» / «FOLLOW-UP» mode to measure the blood pressure. Make sure the Bluetooth software provided with the device is installed on the computer. 32 EN Error messages If an error occurs during measurement, the measurement is interrupted and an error message «Err» is displayed. • Please contact your local Microlife service center if the error persists. • If you think the results are unusual, please read through the information in this instruction manual carefully. 33 Error Description Potential cause and remedy «Err 1» Signal too weak The pulse signals on the cuff are too weak. Re-position the cuff and repeat the measurement. «Err 2» Error signal During the measurement, error signals were detected by the cuff, caused for instance by movement or muscle tension. Repeat the measurement, keeping your arm still. «Err 3» No pressure in the cuff An adequate pressure cannot be generated in the cuff. A leak may have occurred. Replace the batteries if necessary. Repeat the measurement. «Err 5» Abnormal result The measuring signals are inaccurate and no result can therefore be displayed. Read through the checklist for performing reliable measurements and then repeat the measurement. «HI» Pulse or cuff pressure too high The pressure in the cuff is too high (over 300 mmHg) OR the pulse is too high (over 200 beats per minute). Relax for 5 minutes and repeat the measurement. «LO» Pulse too low The pulse is too low (less than 40 beats per minute). Repeat the measurement. 34 EN Safety, care, accuracy test and disposal Safety and protection This device may be used only for the purpose described in this booklet. The device comprises of sensitive components and must be treated with caution. The manufacturer cannot be held liable for damage caused by incorrect application. • Ensure that children do not use the device unsupervised; some parts are small enough to be swallowed. Observe the storage and operating conditions described in the “Technical specifications” section of this manual. Protect the device from water and moisture Protect the device from direct sunlight Protect the device from extreme heat and cold • • Do not use the device if you think it is damaged or Avoid proximity to electromagnetic fields, such as those produced by mobile phones • Read the further safety instructions in the Never open device • Do not connect the device to a computer Protect device from impact and drops Only activate the pump when cuff is installed. if anything appears unusual. individual sections of the instruction manual. until prompted to do so by the computer software. 35 Device care Cleaning the cuff Clean the device with a soft, dry cloth. DO NOT wash the cuff. DO NOT iron the cuff cover. Do not wash the cuff! AU SC ULT LLO 1st FO W UP IN Do not iron the cuff! R VA SU ES P R c. se TE RE Accuracy test Disposal We recommend the WatchBP Office device be tested for accuracy every 2 years or after mechanical impact (e.g. being dropped). Please contact Microlife to arrange for an accuracy test. Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations, and not as domestic waste. 36 EN Technical specifications Operation temperature/humidity: 10 - 40 °C / 50 - 104 °F Storage temperature/ humidity: Weight: • • -20 - +50 °C / -4 - +122 °F • 15 - 90 % relative maximum humidity • 1100 g (including rechargeable • • IEC60601-1 General requirement for Reference to Standards: EN 1060-1 /-3, NIBP-requirements safety • IEC60601-1-2 Requirements for EMC • EN1060-4, NIBP clinical investigation • ANSI/AAMI SP10, NIBP requirements • Bluetooth system to V2.0 • FCC part15C battery pack) Dimensions: Measuring method: • 200 x 125 x 90 mm • Oscillometric, corresponding to Korotkoff Measurement range: Cuff pressure display: • 30 - 280 mmHg – blood pressure • 40 - 200 beats per minute – pulse • Range: 0 - 299 mmHg • Resolution: 1 mmHg • Static accuracy: pressure within ±3 Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. mmHg • Pulse accuracy: ±5 % of the readout value Voltage source: • Rechargeable battery pack; 4.8V C4000 mAh • Mains adapter DC 7.5V, 2 A 37 5.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment that may cause undesired operation of the device. generates, uses and can radiate radio frequency energy and, if FCC RF Radiation Exposure Statement: not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions: 1) this device may not cause interference and 2) this device must accept any interference, including interference 38 EN Guarantee card This device is covered by a two-year guarantee and accessories are cover by a one-year guarantee from the date of Name: Address: purchase. This guarantee is valid only on presentation of the guarantee card Date: completed by the owner confirming date of Telephone: purchase or purchase receipt. Product: WatchBP Office Product Number: Twin200 Date: Email: Europe / Middle-East / Africa Asia North / Central / South America Microlife WatchBP AG Espenstrasse 139 9443 Widnau, Switzerland Tel +41 71 727 7000 Fax +41 71 727 7011 Email: watchbp@microlife.ch www.watchbp.com Microlife Corporation 9F, 431, RuiGang Road, NeiHu Taipei, 114, Taiwan, R.O.C. Tel +886 2 8797 1288 Fax+886 2 8797 1283 Email: watchbp@microlife.com.tw www.watchbp.com Microlife Medical Home Solutions, Inc. 2801 Youngfield St., Suite 241 Golden, CO 80401, USA Tel +1 303 274 2277 Fax +1 303 274 2244 Email: watchbp@mimhs.com www.watchbp.com IB WatchBP Office 2508
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24 Create Date : 2008:06:30 11:44:58+08:00 Modify Date : 2008:06:30 11:45:12+08:00 Metadata Date : 2008:06:30 11:45:12+08:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 9979 bytes, use -b option to extract) Version ID : 1 Instance ID : uuid:99aefe3f-0755-704e-a9a7-037af7bbafb0 Document ID : adobe:docid:indd:983ca822-3eb8-11dd-9347-e67b872d54ed Rendition Class : proof:pdf Derived From Instance ID : 983ca821-3eb8-11dd-9347-e67b872d54ed Derived From Document ID : adobe:docid:indd:ccdc659f-3582-11dd-9ae5-d6956278dd3b Derived From Version ID : 1 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:40B3BB8D2E9611DDAFF3E1C72CE0D0D4, uuid:511ef49e-fbb4-481d-a03b-7bec53aca300, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:85add730-14bf-4f55-a689-848bdcd12bbf, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:6e50005f-8828-42f5-ad26-52b742bdd9a7, uuid:ed05fce7-2b35-41b4-9f1c-75af2e780cec, uuid:c7ff1e4d-a688-40bb-9bd8-0988f4b2bce9, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:54b304e9-450f-4c1c-b245-7f1f0a8ebbb6, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:075b8ff3-56a5-4ca3-a71e-4c4b220c2fb8, uuid:b0ade4a5-f631-41c8-85fb-cd4eeec99262, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:278f680e-3a2f-415f-aa54-14eceab3a7a1, uuid:3d609a8b-603b-46f8-b0a6-eb5ca8d91dfe, uuid:9c0c8f85-1da3-4791-83bd-3854d274aea0, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:ed05fce7-2b35-41b4-9f1c-75af2e780cec, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:28eb8e4d-592e-4c7d-9808-9f35ca8871d9, uuid:0e970e67-4f02-444f-ab6c-4e46ecb386ca, uuid:3d609a8b-603b-46f8-b0a6-eb5ca8d91dfe, uuid:5e5aa24a-5361-4b23-be92-0e4485643746, uuid:84f5086b-66a3-4776-9f1d-1625549e5d9c Manifest Reference Document ID : uuid:B03ED04D24CE11DDA93CF3AF1A50FB54, uuid:4A873A30233F11DD8EE8DD8F8CE47694, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:A569BE51233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE4D233E11DD8EE8DD8F8CE47694, uuid:A04A1E7824D311DDB87EBDAFA93FA33C, uuid:3F19B96A235011DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:E2D92C792E8D11DDBD27EF4371DBD84E, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:A569BE55233E11DD8EE8DD8F8CE47694, uuid:50451AF624D911DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0024ED11DD9EE2ED0C9DBE8A73, uuid:EAC25A0224ED11DD9EE2ED0C9DBE8A73, uuid:2B17E591274B11DD8559C844805CA816, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A04A1E7824D311DDB87EBDAFA93FA33C, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:A569BE4F233E11DD8EE8DD8F8CE47694, uuid:A569BE53233E11DD8EE8DD8F8CE47694, uuid:EAC25A0224ED11DD9EE2ED0C9DBE8A73, uuid:E46A156C24E911DD9EE2ED0C9DBE8A73, uuid:4A873A33233F11DD8EE8DD8F8CE47694 Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 41 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools