WEB Terminal NEXTERM SE Overview 1Minet INC      User’s Manual            Video Cable : Shielded Interface Cable must be used to ensure product compliance
WEB Terminal NEXTERM SE Overview  2 Minet INC 1. NEXTERM SE  Overview  1.1 Introduction “ Easy Installation, Optimized Functions and The Lowest Price”  It is this web terminal’s strong points that you can expect when you utilize it in your environments.  Under the basic environment of server based computing and internet connection speed of 56Kbps, you can use various applications on the high performance servers running Windows 2000 Server OS as well as internet connection.   Classification NEXTERM SE  Operating Mode  WBT(Windows Based Terminal) CPU  Intel StrongArm 206MHZ(235MIPS) SDRAM  16M Flash  8M Operating System  Windows CE 3.0  1.2 Functions All application programs are operated in servers. NEXTERM SE  as a client transfers only the inputs of mouse or keyboard to  sever and the result of application programs, which operates on the server to the client using protocol (RDP or ICA). Therefore the traffic that  causes problems in the existing network will be reduced and the client  specification does not require high performance.
WEB Terminal NEXTERM SE Overview 3Minet INC 1.3 Features As Operating System, Windows CE is utilized NEXTERM SE  has an open architecture and uses 32-bit multitasking and multi-thread operating system that support various functions:  l Utilizes a kernel based on the architecture of Windows NT l Supports pre-occupied multitasking and multi-thread l Provides users with friendly GUI environment l Booting process is not necessary since the operation system is stored on ROM  StrongARM CPU of Intel utilized l Low power (4W) Operating available l Size and weight reduced l Low noise (Cooling fan unnecessary)  Quick Booting Circuit Design (Compared to personal computer)  When powering system on, system booting is performed in the last task environment  Minimized Size There are unnecessary elements such as HDD, FDD, CD-ROM and cooling fan.  Server Environment Available l Programs are executed in servers and the results of the execution are displayed on the client l Multi-user can connect to the server simultaneously and execute each different program independently.
WEB Terminal NEXTERM SE use preparations 3Minet INC 2. NEXTERM SE  Use Preparations  This chapter provides the structure and setting method of NEXTERM SE .  2.1 System Structure You must be familiar with the system structure for the proper connection of peripheral devices.  l Basic supplied parts are: Monitor, Mount (main frame), Keyboard, Mouse and Adapter.  NEXTERM SE  Front     Name Functions Description Headphone  Input terminal of headphone Power Button  Monitor OFF, SUSPEND MODE, RESET function
WEB Terminal NEXTERM SE  use preparations  14Minet INC NEXTERM SE  Rear                                 HEADPHONE    Name Functions Description RS-232C  This is connected to D-type connector that consists of 9 pins and interface with other serial devices for transmitting/receiving data MOUSE  PS/2 Port, connected to MINI-DIN connector made up of 6 pins RS-232C  This is connected to D-type connector that consists of 9 pins and interface with other serial devices for transmitting/receiving data KEY  PS/2 Port, connected to MINI-DIN connector made up of 6 pins LAN  Single line for digital transmission.  This interface is connected to a RJ-45 Jack made up of 8 pins. Microphone and Headphone  Input terminal of microphone and headphone Power This is connected to an adapter that supplies power to the system.  RS-232C (Serial devices)  MOUSE(PS/2) KEY(PS/2) LAN  Power VGA(monitorUSB
WEB Terminal NEXTERM SE use preparations 5Minet INC 2.2 Connecting the Components This section shows how to install the components. Note: the power should be off during the system connection.                                1 Connecting Keyboard Connect the keyboard to  its port after checking whether the port is PS/2. 2 Connecting Mouse Connect the mouse to  its port after checking whether the port is PS/2. 3 Connecting LAN Connect the RJ-45 jack to the LAN port. Connect the microphone to the microphone port. Connect the speaker or headphone to the audio port. 5 Connecting Power Connect the adapter to the POWER port and outlet. Be sure that you must use a supplied adapter. Connecting Speaker and Microphone Connecting other connection devices 4 Connecting Monitor Connect the monitor signal cable, which is attached to the monitor with the VGA port
WEB Terminal NEXTERM SE use preparations 6Minet INC 2.3 Connecting external devices NEXTERM SE  has RS-232C port that can connect additional external devices.  Serial Port Serial port can be connected to an external modem or other devices that support the serial port.     2.4 Power Button This section explains the power button on he front panel of the mount (main frame). If you press this button within 0.5 with system on after adapter connected, the screen will be ON/OFF. The mode will change into the Suspend mode (CPU is resting) if you press it for 0.5 ∼ 3 seconds. And the system will be reset if you press it for 3 seconds or longer. You can press it again in order to return to the normal operation mode from the screen off or suspend mode.
WEB Terminal Operation of NEXTERM SE 7Minet INC 3. Operation of NEXTERM SE  For more detailed information, ask the server administrator.  3.1 Setup of Operating Environment This section describes how to setup the operating environment of WEB Terminal.     3.1.1 Preference setting Press the mouse right button on the background screen, and then click Preference. Terminal Preference will appear.   Terminal preference has the following 2 taps. l Manufacture : This shows factory-default settings and operating system version information. l Preference : This enable to set the name and information of this terminal, type of keyboard and screen saver function. If you select the bottom option, the terminal environment will be reset to factory-default settings.   3.1.2 System Setup  Press the mouse right button on the background screen in order to display the menu, and then click “System Setup -> OS & Memory”. System Properties window will appear.  General displays the system information and Memory displays the system memory management information.  You can divide the Storage Memory and Program Memory by moving the scroll bar using a mouse.  You should allocate more space to Program Memory if many windows are displayed or a large execution file is running. You should allocate more space to Storage Memory if there are many files to be stored while using E-mail or Web surfing.   3.1.3 Display Setup  Press the mouse right button on the background screen in order to display the menu, and then click System Setup -> Display to open MQConfig window.
WEB Terminal NEXTERM SE  use preparations  14Minet INC  If you select Display Setting tap, you can set color, resolution and recovery rate. You can watch a normal screen in case you adjust the desktop size and CRT Viewport to the same size. If you have changed the settings, don’t reboot after pressing OK button on the screen. Only reboot after press “Save”.  3.1.4 Keyboard Setup  Press the mouse right button on the background screen in order to display the menu, and then click System Setup -> Input to open Keyboard Properties window. You can change the speed setting of keyboard button.   3.1.5  Network Setup  For more detailed information, ask the server administrator. Press the mouse right button on the background screen in order to display the menu, and then click System Setup  -> NETWORK to open NETWORK CONFIGURATION window.   Select CS8900A ETHERNET DRIVER, and then click Properties.  Select one of the following options from the IP Address window. l If the network uses Dynamic Host Configuration Protocol (DHCP), use IP information provided by DHCP.  l If you want to use Static IP information allocated to you, click the below IP address Type IP Address, Subnet Mask, and Gateway. Click Name Server tap in order to display the next screen.  Type IP of DNS Server.  Click the User information of the initial screen in order to type the ID and PASSWORD to be used on the network, and then enter the related information.  In order to save the typed information after verifying them, click “Registry Save” icon.
WEB Terminal Operation of NEXTERM SE 13Minet INC 3.1.6 Sound Setup  Press the mouse right button on the background screen in order to display the menu, and click System Setup  -> Sound in order to open Volume & Sounds Properties window. You can control the various sound and volume.  3.2 Network Environment View  3.2.1 PING  Press the mouse right button on the background screen in order to display the menu, and click NETWORK TEST -> PING to open PING window. You can check the connection condition when typing the opposite side IP or name on the Destination Hostname or IP section and pressing the Start.   3.2.2 Ipconfig  Press the mouse right button on the background screen in order to display the menu, and click NETWORK TEST -> Ipconfigf to open Ipconfig window.  When clicking the Ipconfig button, the information of the operating network will appear.  3.3 Operation of Connection Manager  This is used to connect WEB Terminal to servers. If users didn’t set the automatic start connection, Connection Manager will be displayed automatically when starting and ending WEB Terminal.  1. Click “Add” from Configure window. New Connection window will appear. 2. Select one of the following connection protocols. l Citrix Independent Computing Architecture Protocol (ICA) l Microsoft Remote Desktop Client Protocol (RDP) 3. Click “OK”.  As Connection is created, registration is completed on the Connection Name list.  3.3.1 Additional Creation of ICA Connection  1. Select “Citrix ICA Client” of New Connection window in order to display Specify Connection Type window.
WEB Terminal NEXTERM SE  use preparations  14Minet INC  2. Specify a connection type. l Network Connection – Direct connection line is required such as 10/100Base-T. l Dial-in Connection – uses a modem.  3. Click “Next” 4. All existing Citrix servers or applications on the servers will be inquired and recognized. Select required servers or applications. If the server list doesn’t appear,  search it again using  “Refresh” or type the server name or IP to connect directly. 5. Click “Next”. If you select “FINISH”, following option will be saved without specification. 6. You are able to change the sever name or create an icon on the background screen. 7. Click “Next”. 8. Configuration can be made in such a way that the applications can be used from the selected server. You can leave it blank in order to specify Command Line and Working Directory or to use Windows NT desktop. 9. Click “Next”. 10. Specify Username, Password and Domain in order to logon the server automatically. 11.  Click “Next”. 12. Specify 16, 256 or Thousands Window Colors on the Select Window Option window. 13. Click “Next”. 14. You can configure the ICA session. l Compress Data Stream – select it when connection is made with modem (modem dial-up) or WAN(wide area network). l Enable Sound  – select it when LAN (Local area network) is the same as 10/100Base T. When using Sound through WAN and modem, increasing usage of bandwidth causes some problems. l If you use modem or WAN, set SOUND QUALITY to LOW and SPEEDSCREEN to ON. 15. Click “Next”. 16. Set the network environment connecting the server. 17. Click “Finish”. Now the installation of ICA connection is finished and it is ready to connect to the server.
WEB Terminal Operation of NEXTERM SE 13Minet INC  3.3.2 Additional Creation of RDP Connection  1. Select Microsoft Remote Desktop Client of New Connection window in order to display WTS Connection Wizard. 2. Type a name for new connection on the Name section. 3. Type the name and IP address of the server to be connected to the server section. 4. Check Low Speed Connection when connecting to the server through low bandwidth lines such as a modem or WAN. 5. Click “Next”. 6. If you want to logon to server automatically, select Automatic Logon, and then type your User name, Password and Domain. 7. Click “Next”. 8. You can configure the Application that is selected instead of the Desktop.  Select Application file name, and then  specify Command Lined and Working Directory or leave it blank to use Windows NT desktop. 9. Click “Next”. 10. Click “Finish”. Now the installation of Connection Wizard is finished and it is ready to connect to the server.  3.3.3 Editing and Deleting Connections   1. Select ICA connection to be edited form the Connection Name list. 2. If you click “Edit”, the following window will appear. 3. You can modify on each tap. Refer to the  “Additional Creation of ICA Connection” for the related tap information  RDP Connection Editing 1. Select RDP connection to be edited from Connection Name list. 2. Click “Edit” and the following “Edit Connection” will appear.  Edit Connection window consists of the following two tabs. l Net Connections – enable you to edit the connection or automatically logon.  l Application  – unable to move automatically to the file name or working directory path whenever connecting to the server and starting the session.
WEB Terminal NEXTERM SE  use preparations  14Minet INC  3. Change the sections that need to be changed in Net Corrections or Application. 4. When it done, click “OK”. Refer to  “Additional Creation of RDP Connection” for more information of each section. Connection Deleting 1. Select connection to be edited from Connection Name list 2. Click “Delete”. 3. Click “Yes”.  Startup connections Setting It provides automatic connection to the server whenever the terminal is started up. 1. Click “Startup” and the following Connection Startup window will appear.  2. Select the following Startup Options. l Make the selected connection your default connection Connection selected from NEXTERM SE  Connection Manager is used as default. This default connection is highlighted when  turning NEXTERM SE  on and NEXTERM LGESP  Connection Manager screen appears l Automatically start the selected connection at startup The system will be started up automatically with the selected connection whenever you operate NEXTERM SE . 3. Click “OK” in order to store the changed data.  Startup Connections Closing 1. Select Auto-start Connection Name, and then click  “Startup”. NEXTERM SE  Connection Startup screen will appear.  2. Click “Make the selected connection your Default connection”, and then click “OK”. Select Connection, and then click “End”.  3.3.4 Connecting Servers  NEXTERM LE  Connection Manager lists all available network connection. In order to connect the server, follow the next steps.  1. Select a Connection Name on the list. 2. Click  “Connect” or double click “Connection Name”. If the connection has been defined as automatic logon, NEXTERM SE  will be connected and logon automatically.
WEB Terminal Operation of NEXTERM SE 13Minet INC 3. In case the logon is not automatic, the Window Logon Information window will appear. Typing user’s accourt will complete the logon.   3.3.5 Using of NEXTERM SE  Hot Keys   Hot Keys used to simplify the switching process between active sessions.  By using Hot Keys instead of NEXTERM SE  Connection Manager, you can switch automatically each program through simple key manipulation.  Hot Key Function CTRL+ALT+UP.Arrow  Changes to Up between active sessions CTRL+ALT+DOWN.Arrow  Changes to Down between active sessions CTRL+ALT+HOME  Changes to default session automatically CTRL+ALT+END The screen will be changed directly to NEXTERM LE  Connection Manager. <F2> If Connection Manager is running, the screen will be changed Terminal Properties Screen  Unless the Hot Keys are working, refer to the instructions of  “Multi Connections Start”.  Multi Connections Start l NEXTERM SE  is able to perform multi connections  simultaneously and the number of available connections is limited per the RAM capacity. 1. Press CTRL+ALT+END to access into NEXTERM SE  Connection Manager.  2. Select Connection Name, and then click “Connect”. l In order to change the connection under operating, you should follow the below steps. 1. Press CTRL+ALT+END to access into NEXTERM SE  Connection Manager. 2. Select Connection Name and click  “Connect”, or press CTRL+ALT+UP.Arrow or CTRL+ALT+DOWN.Arrow. 3.4 Client setting and save  3.4.1 Client Setting  Press the mouse right button on the background screen in order to display the menu, and then press Client setting to open window.
WEB Terminal NEXTERM SE  use preparations  14Minet INC  l ICA Setting Press “Global Setting” button in order to change various settings on the window.   l RDP Setting You can select RDP Encryption Enable option.  3.4.2 SAVE If you press the mouse right button on the  background screen in order to display the  menu, and then press  “SAVE”. The information that users have changed is saved on the FLASH ROM, so it can not disappear, when the power is gone off.   3.5 Closing connections  3.5.1 Disconnecting a connection  Click the “system exit” in its Windows Start menu. “Logoff” or “Disconnect” will be displayed. “Logoff” closes all application programs and “Disconnect” leaves application programs operating and just disconnects from the server. If you end the system using  “Disconnect”, the same  environment as before will be configured when connecting the same account.  3.5.2 Terminal Ends  Press the mouse right button on the background screen in order to display the menu, and then press Shutdown to open the window.  l Check the Suspend System, and then press  “OK”. The terminal will be the “suspend mode”. When pressing the power button again,  previous task environment will be executed.  But the network session may be disconnected due to connected environment and return time. l System, and then press l be rebooted. Unsaved information will disappear.
WEB Terminal Troubleshooting 15Minet INC 4. Troubleshooting  This section provides some solutions to  occurred problems during operating NEXTERM SE .  The monitor screen is blank l Check whether the power cord has been inserted properly into the terminal. l Check whether the power cord has been inserted properly into an AC outlet. l Check whether the screen is OFF. l Check whether the system is on SUSPEND mode.  The mouse does not work l Check whether the mouse jack has been inserted properly the mouse port. l Check whether the mouse ball is operating freely.  The Keyboard does not respond l Check whether the keyboard has been connected properly to the keyboard port. l Check whether power is being supplied properly to NEXTERM SE .  The Network connection does not work l Check whether the cables are connected properly to the LAN port. l Verify the network settings. l Check whether the network address is valid. l Verify the configuration of the server terminal.
WEB Terminal System Specifications  16Minet INC 5. System Specifications  The specification of NEXTERM SE  is listed as below.  ¿ Hardware Specification   Item NEXTERM SE  CPU  -  Intel Strong ARM 32Bit RISC Processor -  206 MHz (235MIPS) Flash Memory  -  8MB FLASH -  Expandable to 16MB RAM Memory  -  16MB SDRAM -  Expandable to 32MB  Audio  -  16-bit stereo  Video  -  1024 X 768 16 bit True colors -  Up to 1280 X 1024 256 colors  ¿ Communications and Input/Output Specification   Item NEXTERM SE  Networking Protocol  -  Ethernet 10 Base T Ethernet -  TCP/IP with DNS, DHCP, and PPP Communication Protocol  -  Microsoft RDP -  Citrix ICA Serial Port  -  1 DB-9 RS232C Serial Port Display Port  -  Analog VGA Video Output Audio Port  -  Earphone Jack -  Microphone in Keyboard and Mouse Port  -  Keyboard and Mouse Port (PS/2 Keyboard and Mouse included)