WEB Terminal
U s e r’s Manual
Video Cable : Shielded Interface Cable must be used to ensure product compliance
NEXTERM SE Overview
Minet INC
WEB Terminal
1. NEXTERM SE
Overview
1.1 Introduction
“ Easy Installation, Optimized Functions and The Lowest Price”
It is this web terminal’s strong points that you can expect when you utilize it
in your environments.
Under the basic environment of server based computing and internet connection
speed of 56Kbps, you can use various applications on the high performance
servers running Windows 2000 Server OS as well as internet connection.
Classification
NEXTERM SE
Operating Mode
WBT(Windows Based Terminal)
CPU
Intel StrongArm
206MHZ(235MIPS)
SDRAM
16M
Flash
8M
Operating System
Windows CE 3.0
1.2 Functions
All application programs are operated in servers. NEXTERM SE
as a client
transfers only the inputs of mouse or keyboard to sever and the result of
application programs, which operates on the server to the client using protocol
(RDP or ICA). Therefore the traffic that causes problems in the existing
network will be reduced and the client specification d o e s not require high
performance.
NEXTERM SE Overview
Minet INC
WEB Terminal
1.3 Features
As Operating System, Windows CE is utilized
NEXTERM SE
has an open architecture and uses 32-bit multitasking and multi-
thread operating system that support various functions:
Utilizes a kernel based on the architecture of Windows NT
Supports pre-occupied multitasking and multi-thread
Provides users with friendly GUI environment
Booting process is not necessary since the operation system is stored on
ROM
StrongARM CPU of Intel utilized
Low power (4W) Operating available
Size and weight reduced
Low noise (Cooling fan unnecessary)
Quick Booting Circuit Design (Compared to personal computer)
When powering system on, system booting is performed in the last
task environment
Minimized Size
There are unnecessary elements such as HDD, FDD, CD-ROM and cooling fan.
Server Environment Available
Programs are executed in servers and the results of the execution are
displayed on the client
Multi-user can connect to the server simultaneously and execute each
different program independently.
NEXTERM SE Overview
Minet INC
WEB Terminal
2. NEXTERM SE
Use Preparations
This chapter provides the structure and setting method of NEXTERM SE .
2.1 System Structure
You must be familiar with the system structure for the proper connection of
peripheral devices.
Basic supplied parts are: Monitor, Mount (main frame), Keyboard, Mouse and
Adapter.
NEXTERM SE
Front
Name
Headphone
Power Button
NEXTERM SE use preparations
Functions Description
Input terminal of headphone
Monitor OFF, SUSPEND MODE, RESET function
Minet INC
WEB Terminal
NEXTERM SE
Rear
Power
RS-232C
LAN
MOUSE(PS/2)
KEY(PS/2)
(Serial
devices)
VGA(monitor
USB
HEADPHONE
Name
Functions Description
RS-232C
MOUSE
RS-232C
KEY
LAN
Microphone
Headphone
Power
NEXTERM SE
and
This is connected to D-type connector that consists of 9 pins and
interface with other serial devices for transmitting/receiving
data
PS/2 Port, connected to MINI-DIN connector made up of 6 pins
This is connected to D-type connector that consists of 9 pins and
interface with other serial devices for transmitting/receiving
data
PS/2 Port, connected to MINI-DIN connector made up of 6 pins
Single line for digital transmission.
This interface is connected to a RJ-45 Jack made up of 8 pins.
Input terminal of microphone and headphone
This is connected to an adapter that supplies power to the system.
use preparations
Minet INC
14
WEB Terminal
2.2 Connecting the Components
This section shows how to install the components.
Note: the power should be off during the system connection.
Connecting
Speaker
and Microphone
Connect
headphone
the
to
speaker
the
or
audio
port.
Connecting
other
connection devices
1 Connecting Keyboard
Connect
the
keyboard
to
its
port
after checking whether the port is
PS/2.
2 Connecting Mouse
Connect the microphone to
Connect the mouse to its port after
the microphone port.
checking whether the port is PS/2.
3 Connecting LAN
Connect the RJ-45 jack t o t h e L A N
port.
4 Connecting Monitor
Connect
the
monitor
signal
cable,
which is attached to the monitor with
the VGA port
5 Connecting Power
Connect the adapter to the POWER port
and outlet. Be sure that you must use
a supplied adapter.
NEXTERM SE use preparations
Minet INC
WEB Terminal
2.3 Connecting external devices
NEXTERM SE
has RS-232C port that can connect additional external devices.
Serial Port
Serial port can be connected to an external modem or other devices that support
the serial port.
2.4 Power Button
This section explains the power button on he front panel of the mount (main
frame).
If you press this button within 0.5 with system on after adapter connected, the
screen will be ON/OFF. The mode will change into the Suspend mode (CPU is
resting) if you press it for 0.5 ∼ 3 seconds. And the system will be reset if
you press it for 3 seconds or longer. You can press it again in order to return
to the normal operation mode from the screen off or suspend mode.
NEXTERM SE use preparations
Minet INC
WEB Terminal
3. Operation of NEXTERM SE
For more detailed information, ask the server administrator.
3.1 Setup of Operating Environment
This section describes how to setup the operating environment of WEB Terminal.
3.1.1 Preference setting
Press
the
mouse right
button
on
the
background screen,
and
then
click
Preference. Terminal Preference will appear.
Terminal preference has the following 2 taps.
Manufacture : This shows factory -default settings and operating system
version information.
Preference : This enable to set the name and information of this terminal,
type of keyboard and screen saver function. If you select the bottom option,
the terminal environment will be reset to factory-default settings.
3.1.2 System Setup
Press the mouse right button on the background screen in order to display the
menu, and then click “System Setup -> OS & Memory”. System Properties window
will appear.
General displays the system information and Memory displays the system memory
management information.
You can divide the Storage Memory and Program Memory by moving the scroll bar
using a mouse.
You should allocate more space to Program Memory if many windows are displayed
or a large execution file is running. You should allocate more space to Storage
Memory if there are many files to be stored while using E-mail or Web surfing.
3.1.3 Display Setup
Press the mouse right button on the background screen in order to display the
menu, and then click System Setup -> Display to open MQConfig window.
Operation of NEXTERM SE
Minet INC
WEB Terminal
If you select Display Setting tap, you can set color, resolution and recovery
rate. You can watch a normal screen in case you adjust the desktop size and CRT
Viewport to the same size. If you have changed the settings, don’t reboot after
pressing OK button on the screen. Only reboot after press “Save”.
3.1.4 Keyboard Setup
Press the mouse right button on the background screen in order to display the
menu, and then click System Setup -> Input to open Keyboard Properties window.
You can change the speed setting of keyboard button.
3.1.5
Network Setup
For more detailed information, ask the server administrator.
Press the mouse right button on the background screen in order to display the
menu, and then click System Setup -> NETWORK to open NETWORK CONFIGURATION
window.
Select CS8900A ETHERNET DRIVER, and then click Properties.
Select one of the following options from the IP Address window.
If the network uses Dynamic Host Configuration Protocol (DHCP), use IP
information provided by DHCP.
If you want to use Static IP information allocated to you, click the below
IP address
Type IP Address, Subnet Mask, and Gateway.
Click Name Server tap in order to display the next screen.
Type IP of DNS Server.
Click the User information of the initial screen in order to type the ID and
PASSWORD to be used on the network, and then enter the related information.
In order to save the typed information after verifying them, click “Registry
Save” icon.
NEXTERM SE
use preparations
Minet INC
14
WEB Terminal
3.1.6 Sound Setup
Press the mouse right button on the background screen in order to display the
menu, and
click System Setup
-> Sound in order to open Volume
& Sounds
Properties window.
You can control the various sound and volume.
3.2 Network Environment View
3.2.1 PING
Press the mouse right button on the background screen in order to display the
menu, and click NETWORK TEST -> PING to open PING window.
You can check the connection condition when typing the opposite side IP or name
on the Destination Hostname or IP section and pressing the Start.
3.2.2 Ipconfig
Press the mouse right button on the background screen in order to display the
menu, and click NETWORK TEST -> Ipconfigf to open Ipconfig window.
When clicking the Ipconfig button, the information of the operating network
will appear.
3.3 Operation of Connection Manager
This is used to connect WEB Terminal to servers.
If users didn’t set the automatic start connection, Connection Manager will be
displayed automatically when starting and ending WEB Terminal.
1. Click “Add” from Configure window. New Connection window will appear.
2. Select one of the following connection protocols.
Citrix Independent Computing Architecture Protocol (ICA)
Microsoft Remote Desktop Client Protocol (RDP)
3. Click “OK”.
As Connection is created, registration is completed on the Connection Name list.
3.3.1 Additional Creation of ICA Connection
1. Select “Citrix ICA Client” of New Connection window in order to display Specify
Connection Type window.
Operation of NEXTERM SE
13
Minet INC
WEB Terminal
2. Specify a connection type.
Network Connection – Direct connection line is required such as 10/100BaseT.
Dial-in Connection – uses a modem.
3. Click “Next”
4. All existing Citrix servers or applications on the servers will be inquired and
recognized. Select required servers or applications. If the server list doesn’t
appear, search it again using “Refresh” or type the server name or IP to
connect directly.
5. Click “Next”. If you select “FINISH”, following option will be saved without
specification.
6. You are able to change the sever name or create an icon on the background
screen.
7. Click “Next”.
8. Configuration can be made in such a way that the applications can be used from
the selected server. You can leave it blank in order to specify Command Line
and Working Directory or to use Windows NT desktop.
9. Click “Next”.
10.
Specify
Username,
Password
and
Domain
in
order
to
logon
the
server
automatically.
11.
Click “Next”.
12. Specify 16, 256 or Thousands Window Colors on the Select Window Option window.
13. Click “Next”.
14. You can configure the ICA session.
Compress Data Stream – select it when connection is made with modem (modem
dial-up) or WAN(wide area network).
Enable Sound – select it when LAN (Local area network) is the same as
10/100Base T. When using Sound through WAN and modem, increasing usage of
bandwidth causes some problems.
If you use modem or WAN, set SOUND QUALITY to LOW and SPEEDSCREEN to ON.
15. Click “Next”.
16. Set the network environment connecting the server.
17. Click “Finish”.
Now the installation of ICA connection is finished and it is ready to connect
to the server.
NEXTERM SE
use preparations
Minet INC
14
WEB Terminal
3.3.2 Additional Creation of RDP Connection
1. Select Microsoft Remote Desktop Client of New Connection window in order to
display WTS Connection Wizard.
2. Type a name for new connection on the Name section.
3. Type the name and IP address of the server to be connected to the server
section.
4. Check Low Speed Connection when connecting to the server through low bandwidth
lines such as a modem or WAN.
5. Click “Next”.
6. If you want to logon to server automatically, select Automatic Logon, and then
type your User name, Password and Domain.
7. Click “Next”.
8. You can configure the Application that is selected instead of the Desktop.
Select Application file name, and then specify Command Lined and Working
Directory or leave it blank to use Windows NT desktop.
9. Click “Next”.
10. Click “Finish”.
Now the installation of Connection Wizard is finished and it is ready to connect
to the server.
3.3.3 Editing and Deleting Connections
1. Select ICA connection to be edited form the Connection Name list.
2. If you click “Edit”, the following window will appear.
3. You can modify on each tap.
Refer to the “Additional Creation of ICA
Connection” for the related tap information
RDP Connection Editing
1. Select RDP connection to be edited from Connection Name list.
2. Click “Edit” and the following “Edit Connection” will appear.
Edit Connection window consists of the following two tabs.
Net Connections – enable you to edit the connection or automatically logon.
Application – unable to move automatically to the file name or working
directory path whenever connecting to the server and starting the session.
Operation of NEXTERM SE
13
Minet INC
WEB Terminal
3. Change
the
sections
that
need
to
be
changed
in
Net
Corrections
or
Application.
4. When it done, click “OK”.
Refer to “Additional Creation of RDP Connection” for more information of
each section.
Connection Deleting
1. Select connection to be edited from Connection Name list
2. Click “Delete”.
3. Click “Yes”.
Startup connections Setting
It provides automatic connection to the server whenever the terminal is
started up.
1. Click “Startup” and the following Connection Startup window will appear.
2. Select the following Startup Options.
Make the selected connection your default connection
Connection selected from NEXTERM SE
Connection Manager is used as default.
This default connection is highlighted when turning NEXTERM SE
NEXTERM LGESP
on and
Connection Manager screen appears
Automatically start the selected connection at startup
The system will be started up automatically with the selected connection
whenever you operate NEXTERM SE .
3. Click “OK” in order to store the changed data.
Startup Connections Closing
1. Select Auto-start Connection Name, and then click “Startup”. NEXTERM SE
Connection Startup screen will appear.
2. Click “Make the selected connection your Default connection”, and then click
“OK”. Select Connection, and then click “End”.
3.3.4 Connecting Servers
NEXTERM LE
Connection Manager lists all available network connection. In order
to connect the server, follow the next steps.
1. Select a Connection Name on the list.
2. Click “Connect” or double click “Connection Name”. If the connection has
been defined as automatic logon, NEXTERM SE
will be connected and logon
automatically.
NEXTERM SE
use preparations
Minet INC
14
WEB Terminal
3. In case the logon is not automatic, the Window Logon Information window will
appear. Typing user’s accourt will complete the logon.
3.3.5 Using of NEXTERM SE
Hot Keys
Hot Keys used to simplify the switching process between active sessions.
By using Hot Keys instead of NEXTERM SE
Connection Manager, you can switch
automatically each program through simple key manipulation.
Hot Key
Function
CTRL+ALT+UP.Arrow
Changes to Up between active sessions
CTRL+ALT+DOWN.Arrow
Changes to Down between active sessions
CTRL+ALT+HOME
Changes to default session automatically
CTRL+ALT+END
The screen will be changed directly to NEXTERM LE
Connection Manager.
If Connection Manager is running, the screen will be
changed Terminal Properties Screen

Unless
the
Hot
Keys
are
working,
refer
to
the
instructions
of
“Multi
Connections Start”.
Multi Connections Start
NEXTERM SE
is able to perform multi connections simultaneously and the
number of available connections is limited per the RAM capacity.
1. Press CTRL+ALT+END to access into NEXTERM SE
Connection Manager.
2. Select Connection Name, and then click “Connect”.
In order to change the connection under operating, you should follow the
below steps.
1. Press CTRL+ALT+END to access into NEXTERM SE
Connection Manager.
2. Select Connection Name and click “Connect”, or press CTRL+ALT+UP.Arrow or
CTRL+ALT+DOWN.Arrow.
3.4 Client setting and save
3.4.1 Client Setting
Press the mouse right button on the background screen in order to display the
menu, and then press Client setting to open window.
Operation of NEXTERM SE
13
Minet INC
WEB Terminal
ICA Setting
Press “Global Setting” button in order to change various settings on the
window.
RDP Setting
You can select RDP Encryption Enable option.
3.4.2 SAVE
If you press the mouse right button on the background screen in order to
display the menu, and then press “SAVE”. The information that users have
changed is saved on the FLASH ROM, so it can not disappear, when the power is
gone off.
3.5 Closing connections
3.5.1 Disconnecting a connection
Click the “system exit” in its Windows Start menu. “Logoff” or “Disconnect” will
be displayed. “Logoff” closes all application programs and “Disconnect” leaves
application programs operating and just disconnects from the server. If you end
the
system
using
“Disconnect”,
the
same
environment
as
before
will
be
configured when connecting the same account.
3.5.2 Terminal Ends
Press the mouse right button on the background screen in order to display the
menu, and then press Shutdown to open the window.
Check the Suspend System, and then press “OK”. The terminal will be the
“suspend mode”.
When pressing the power button again, previous task environment will be
executed. But the network session may be disconnected due to connected
environment and return time.
System, and then press l be rebooted. Unsaved information will disappear.
NEXTERM SE
use preparations
Minet INC
14
WEB Terminal
4. Troubleshooting
This section provides some solutions to occurred problems during operating
NEXTERM SE .
The monitor screen is blank
Check whether the power cord has been inserted properly into the terminal.
Check whether the power cord has been inserted properly into an AC outlet.
Check whether the screen is OFF.
Check whether the system is on SUSPEND mode.
The mouse does not work
Check whether the mouse jack has been inserted properly the mouse port.
Check whether the mouse ball is operating freely.
The Keyboard does not respond
Check whether the keyboard has been connected properly to the keyboard port.
Check whether power is being supplied properly to NEXTERM SE .
The Network connection does not work
Check whether the cables are connected properly to the LAN port.
Verify the network settings.
Check whether the network address is valid.
Verify the configuration of the server terminal.
Troubleshooting
Minet INC
15
WEB Terminal
5. System Specifications
The specification of NEXTERM SE
is listed as below.
¿ Hardware Specification
Item
NEXTERM SE
CPU
Flash Memory
RAM Memory
Audio
Video
Intel Strong ARM 32Bit RISC Processor
206 MHz (235MIPS)
8MB FLASH
Expandable to 16MB
16MB SDRAM
Expandable to 32MB
16-bit stereo
1024 X 768 16 bit True colors
Up to 1280 X 1024 256 colors
¿ Communications and Input/Output Specification
Item
Networking Protocol
Communication Protocol
Serial Port
Display Port
Audio Port
Keyboard and Mouse Port
System Specifications
16
NEXTERM SE
Ethernet 10 Base T Ethernet
TCP/IP with DNS, DHCP, and PPP
Microsoft RDP
Citrix ICA
1 DB-9 RS232C Serial Port
Analog VGA Video Output
Earphone Jack
Microphone in
Keyboard and Mouse Port
(PS/2 Keyboard and Mouse included)
Minet INC


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Creator                         : .歯.Microsoft Word
Create Date                     : 2001:03:29 10:58:58
Title                           : .歯.SE메뉴얼_영문_.PDF
Author                          : .歯.박영준
Producer                        : Acrobat PDFWriter 4.0 Windows¿ë
Modify Date                     : 2001:04:11 11:07:46+09:00
Page Count                      : 22
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJNNEXSE001