Motorola Solutions 89FT4888 PIU AND PIU-XR OF DIOS User Manual Distributed I O System Owner s Manual
Motorola Solutions, Inc. PIU AND PIU-XR OF DIOS Distributed I O System Owner s Manual
Contents
- 1. Users Manual
- 2. Safety Booklet
Users Manual
Owner’s Manual Distributed I/O SystemPiccolo Interface Unit (PIU) and Piccolo-XR Unit 6802974C40-R MOTOROLA and the Stylized M Logo are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their respective owners. Copyright © 2009 Motorola All Rights Reserved 6802974C40-R @6802974C40@ COMMERCIAL WARRANTY (STANDARD) Motorola radio communications products are warranted to be free from defects in material and workmanship for a period of ONE (1) YEAR, (except for crystals and channel elements which are warranted for a period of ten (10) years), from the date of shipment. Parts, including crystals and channel elements, will be replaced free of charge for the full warranty period but the labor to replace defective parts will only be provided for one Hundred-Twenty (120) days from the date of shipment. Thereafter purchaser must pay for the labor involved in repairing the product or replacing the parts at the prevailing rates together with any transportation charges to or from the place where warranty service is provided. This express warranty is extended by Motorola Communications and Electronics Inc., 1301 E. Algonquin Road, Schaumburg, Illinois 60196, to the original purchaser only, and only to those purchasing for purpose of leasing or solely for commercial, industrial, or governmental use. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED WHICH ARE SPECIFICALLY EXCLUDED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL MOTOROLA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. In the event of a defect, malfunction or failure to conform to specifications established by seller, or if appropriate, to specifications accepted by Seller in writing, during the period shown, Motorola, at its option, will either repair or replace the product or refund the purchase price thereof, and such action on the part of Motorola shall be the full extent of Motorola’s liability hereunder. This warranty is void if: a. the product is used in other than its normal and customary manner; b. the product has been subject to misuse, accident neglect or damage; c. unauthorized alterations or repairs have been made, or unapproved parts used in the equipment. This warranty extends only to individual products, batteries are excluded, but carry their own separate limited warranty. Because each radio system is unique, Motorola disclaims liability for range, coverage, or operation of the system as a whole under this warranty except by a separate written agreement signed by an officer of Motorola. Non-Motorola manufactured products are excluded from this warranty, but subject to the warranty provided by their manufacturers, a copy of which will be supplied to you on specific written request. To obtain performance of this warranty, purchaser should contact a Motorola salesperson, or Motorola at the address shown above, attention: Quality Assurance Department. This warranty applies only within the United States. COMPUTER SOFTWARE COPYRIGHTS The Motorola products described in this instruction manual may include copyrighted Motorola computer programs stored in semi conductor memories or other media. Laws in the United States and other countries preserve for Motorola certain exclusive rights for copyrighted computer programs including the exclusive right to copy or reproduce in any form the copyrighted computer program. Accordingly, any copyrighted Motorola computer programs contained in the Motorola products described in this instruction manual may not be copied or reproduced in any manner without the express written permission of Motorola. Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Motorola, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product. EUROPEAN UNION DIRECTIVE 2002/95/EC CONFORMANCE STATEMENT Hereby, Motorola declares that these products are in compliance with the essential requirements and other relevant provisions of Directive 2002/95/EC Restriction of Hazardous Substances Directive. This page left intentionally blank. CONTENTS CONTENTS................................................................................ I INTRODUCTION....................................................................... 1 Scope of this Manual ......................................................................1 General Description........................................................................1 Safety Handling Instructions.........................................................5 INSTALLATION ........................................................................ 7 General ............................................................................................7 PIU Installation...............................................................................8 Mounting the PIU On A Wall Using Screws................................9 Mounting the PIU Using a Bracket.............................................10 PIU DIN Rail Mounting...............................................................11 PIU Electrical Connections..........................................................12 PIU Antenna Connection .............................................................18 Piccolo–XR Installation ...............................................................19 Piccolo–XR Screw Mounting Options ........................................20 Piccolo–XR Electrical Connections.............................................22 THE DIOS PIU AND PICCOLO-XR UNITS ............................ 27 PIU Overview................................................................................27 PIU Communication Ports...........................................................28 PIU Connectors.............................................................................29 PIU LED Operation .....................................................................29 PIU Adapter Operation ...............................................................30 Piccolo-XR Overview ...................................................................35 Piccolo-XR Communication Ports ..............................................35 Piccolo-XR Connector..................................................................36 Contents APPENDIX A: PIU and PICCOLO-XR SPECIFICATIONS.... 37 PIU Specifications.........................................................................37 Environmental ................................................................................37 Mechanical .....................................................................................37 PIU Board.......................................................................................38 Power..............................................................................................39 PICCOLO XR Specifications ......................................................42 Environmental ................................................................................42 Mechanical .....................................................................................42 PICCOLO XR Board......................................................................42 Communication Ports .....................................................................43 Power..............................................................................................44 Regulatory Standards ..................................................................46 Radio Network Freq Band Rated Power .......................46 APPENDIX B: MODELS and ACCESSORIES...................... 49 General ..........................................................................................49 APPENDIX C: ANTENNA ...................................................... 51 General ..........................................................................................51 Flexible Antenna Specifications ..................................................51 Pole Antenna .................................................................................52 Pole Antenna installation .............................................................53 APPENDIX D: PIU/PICCOLO–XR MOUNTING TEMPLATES ................................................................................................. 57 ii INTRODUCTION Scope of this Manual This manual provides instructions for the installation and operation of the Distributed I/O system Piccolo Interface Unit (PIU) and Piccolo–XR units. The Distributed I/O System includes PIUs and Piccolo–XRs. Each PIU can be linked to up to 256 Piccolo–XRs. For more information on the PIU and Piccolo–XR, see the online help of the DIOS Service Toolkit. General Description The Distributed I/O System (DIOS) is a self-sustained system designed to function within the IRRInet irrigation control product line. The DIOS consists of the following components: Piccolo Interface Unit (PIU) Piccolo–XR Units The PIU functions as an interface between the host application (irrigation SW and HW) and the Piccolo–XR units. The PIU and Piccolo-XR are portable devices, which are used in fixed installations. The PIU uses one of its communication ports to link to the host application and radio communication to link to the Piccolo–XR units. Figure 1 provides a general view of the DIOS System. Introduction IRRInet Field Unit Piccolo Interface Unit RS485 or RS232 PIU Piccolo-XR Units I/O's Figure 1 DIOS –General System View The battery-operated Piccolo–XR unit is available in various models with different options of Inputs and Outputs. The Piccolo–XR unit can operate DC latch solenoids (outputs), read status and calculate flow of dry contact meters (inputs). The units are equipped with built-in radio for communication with the PIU. The DIOS automatically builds communication network, using Store and Forward (S&F) technology, enabling the DIOS to cover areas larger than normally possible when using a single radio to communicate with the PIU. Using the DIOS, the IRRInet system opens and closes stations (manually or automatically by irrigation programs), reads dry contact input status, calculates flow rate and accumulates pulses from water meters. Introduction PIU - Piccolo Interface Unit The Piccolo Interface Unit (PIU; see Figure 2) is connected to the IRRInet Field Unit (FU) via RS232 or RS485 serial ports. Each PIU supports up to 256 Piccolo–XR units, with any available I/O combination, limited by the capacity of the IRRInet software only. Utilizing the S&F technology and networking capabilities, the PIU can be linked to Piccolo–XR units positioned in distances of up to 1500-2000 meters (approx. 1 mile), depending on topography, antenna type and antenna installation. The PIU is an interface between the Piccolo–XR and the IRRInet FU, which provides communication and networking operations only. (Monitor and control features are not included in the PIU.) That is: The control and monitor functions are provided either locally, by the Piccolo–XR or by an upper hierarchy unit (i.e. IRRInet FU). The PIU is a portable device, which is used in fixed installations enclosed in an indoor plastic housing. The PIU must be installed by qualified and authorized technicians, so as to meet applicable safety standards and to ensure protection against weather hazards for the unit. If the PIU will be connected to outdoor lines, an interface unit, complying with Clause 6 of the UL 60950 standard must be provided. Introduction Figure 2 PIU – General View Piccolo–XR The Piccolo–XR is an intelligent, microprocessor based unit that can be used to monitor and control local units in a multi unit communication network. Piccolo–XR units communicate data to a PIU while functioning as intelligent nodes in Distributed I/O monitor and control systems. The Piccolo–XR is often used in irrigation and water distribution systems (i.e. irrigation valves, water meters, fertilizing meters, various sensors, flushing filters, and other non-irrigation devices). The Piccolo–XR is ideal for use in applications where very low power consumption is essential. The Piccolo–XR is also available in an outdoor resistant housing (IP66), designed to resist harsh environment, such as exposure to sun, dust, and pouring rain. Introduction Figure 3 Piccolo XR –General View Safety Handling Instructions For safety handling instructions, see the Product Safety and RF Energy Exposure Booklet for PIU and Piccolo XR Units, Motorola publication no. 6802974C70, which is distributed with the devices. The radio frequency band used by the DIOS system has not been harmonized throughout the entire European Economic Area (EEA). Introduction This page left intentionally blank. INSTALLATION General SAFETY SUMMARY Caution Caution The PIU and Piccolo–XR must be installed by qualified and authorized technicians, specifically qualified to handle high voltage if the installation involves high-voltage connections/installations. If the PIU will be installed outdoors, an outdoor plastic housing complying with UL60950 standard clause 6 is required. Note! See Piccolo–XR Screw Mounting Options (page 20) for mounting details. Note! This equipment is tested with specified length cables and in standard enclosure. If longer cables or a different enclosure are used, the installer is responsible to ensure that the installation complies with the requirements of the applicable standards. Installation PIU Installation PIU Dimensions The unit dimensions are (see Figure 4): Width – 4.25" (108 mm), Height – 4.96" (126 mm), Height including antenna – 11.46" (291.1 mm), Depth – 1.67" (42 .6mm), Weight – 0.558 lb (253g) maximum. 42. .67" 6m 4.96” 126 mm 5" 4.2 m 108 11.46 " 291.1mm Figure 4 Dimensions of PIU Unit The PIU is enclosed in a plastic housing, allowing 3 mounting options: Wall mount (Screws) Bracket mount DIN rail mount Installation Before installing the PIU, verify that there is sufficient space around the unit according to the specific installation. Mounting the PIU On A Wall Using Screws 1. Secure two screws (not supplied) of maximum 0.37" (9.5 mm) head size to the wall, 3.256" (82.7 mm) apart. The wall-mounting template in Appendix D can be used to determine the space between both screws. 2. The screws must not protrude from the wall surface by more than 0.23” (6 mm) or by less than 0.16" (4 mm). 3. Attach the unit to the wall, fitting the two key hole shaped cavities on the back cover of the unit over the screws and sliding it down. (See Figure 5.) 1.19" 30.3mm 3.26" 82.7 mm Figure 5 PIU Installation– Screw Mount dimensions Installation Mounting the PIU Using a Bracket 1. Using four M3x6 or M3x8 screws, attach a bracket (not supplied) to the back of the PIU. The upper two bracket holes must be 3.19" (81 mm) apart, and the lower two bracket holes must be 2.40" (61 mm) apart and 2.13" (54 mm) below the upper holes, as shown in Figure 6. 2.13" 54mm 2. Attach the bracket to the mounting surface. 2.40" 61 mm 3.19" 81mm Figure 6 PIU Installation– Bracket Mount dimension 10 Installation PIU DIN Rail Mounting To mount the PIU on a DIN rail (not supplied), slide the PIU onto the rail at the grooves on the back of the unit. See Figure 7 and Figure 8. Figure 7 DIN Rail Attachment – Back View Figure 8 DIN Rail Attachment – Front View 11 Installation PIU Electrical Connections NOTE! Verify that all power connections are made in accordance with the applicable local standards. PIU Ground Connections Use the FKN8254B cable to connect the grounding cable directly to the TB connector of the PIU as shown in Figure 9. NOTE! The grounding connector is also used as an ON/OFF switch, and the unit cannot be powered on without connecting it. Grounding Cable (FKN8254B) Ground Figure 9 PIU Ground connection 12 Installation Power Connection The PIU can be powered by various types of supply sources: Internal (9VDC) battery; External 6V or 12V DC battery; Motorola power supplies – controllers. For example: IRRInet XL, IRRInet XM, IRRIcom, MOSCAD; 24VAC. NOTE! The unit DC voltage range is 6 to 16 volts. 9VDC Internal Battery Incorrect replacement of the battery can result in explosion! Replace only with the same or with an equivalent type of battery recommended by the Caution manufacturer. Dispose of used batteries according to the battery manufacturer instructions. Place a standard 9VDC alkaline battery (not supplied) into the PIU battery chamber (see Figure 10). Battery operation is applicable when operating the unit in a non-radio mode, e.g. when the PIU is used as an adapter. 13 Installation Installation of an Internal Battery 1. Release the screw at the top of the battery chamber door, and slide the door out, as shown in Figure 10. 2. Connect the 9V battery cable (FKN8204B) to the DC power input connector on the back of the unit. 3. Connect the 9V DC battery to the cable. 4. Place the 9V DC alkaline battery in the chamber as shown in Figure 10. 5. Close the battery chamber door and secure with the screw. Screw Battery Chamber Door Figure 10 PIU Battery Chamber 14 Battery Chamber Battery Installation External Battery Power Connections Caution The unit must be powered by a limited power source (12V DC) in accordance with standard UL/IEC 60950-1. See Power in Appendix A below. This connection is used for normal operation of the PIU, when radio communication is required, or when RS485 or RS232 ports are used. 1. Release the screw at the top of the battery chamber door and slide the door out, as shown in Figure 10. 2. Connect the DC Adapter board (FCN6538B) to the DC power input connector on the back of the unit (Figure 11). 3. Connect the FKN8250B 7 ft cable to the DC Adapter board. 4. Connect the other cable end to an external 12VDC battery through 1A fuse (not supplied). 5. Close the battery chamber door and secure with the screw. DC adapter board FCN6538B DC power in FKN8250B 1A Fuse Figure 11 PIU Unit – Rear View with DC Adapter 15 Installation External Power Supply Connections Use the applicable cable from the V152AH PIU installation kit to connect the PIU to Motorola standard controller power supply. 1. Release the screw at the top of the battery chamber door and slide the door out, as shown in Figure 10. 2. Connect one end of the cable to the DC power input connector on the back of the unit. 3. Connect the other end of the cable to the power supply output of a Motorola controller. 4. Close the battery chamber door and secure with the screw. 16 Installation 24VAC Power Connections Caution Caution The PIU must be connected to a power source equivalent to one or more of the following: a. A listed Direct plug-in unit. b. A Class II power source (defined by the National Electrical Code (NEC) and the Canadian Electrical Code (CEC). c. A power source that complies with UL1950 C1.2.1 or UL60950 C1.2.5. The unit must be powered by a limited power source (24V AC) in accordance with the UL/IEC 60950-1 standard. See Power in Appendix A below. 1. Connect the FKN8264B cable to the 24 V AC PWR IN connector as shown in Figure 12. 2. Connect the other end of the cable to the 24 V AC connection of a 110 V AC/220 V AC transformer (not supplied) through a 1 A fuse (not supplied). AC Cable FKN8264B 1A Fuse 24 AC 110/220 V AC Figure 12 24VAC Power In Connection 17 Installation PIU Antenna Connection Flexible Antenna: Attach the flexible monopole antenna to the antenna connector at the top of the unit. See Appendix C for detailed information. Pole Antenna: Attach the FKN8258B antenna cable to the antenna connector at the top of the unit. Connect the other end of the antenna cable to a customer-supplied pole antenna. See Appendix C for detailed information. 18 Installation Piccolo–XR Installation Piccolo–XR Dimensions The unit dimensions are (see Figure 13): Width – 4.6" (117 mm) Height – 5.00" (127 mm) Hight including antenna – 11.46" (291.1 mm) Depth –1.63" (41.5mm) 4.6 m 7m 11 5.00” 127 mm 1. 41. 63" 5m 11.46" 291.1mm Weight – 0.54 lb (240 gr) maximum. Figure 13 Dimensions of the Piccolo–XR Unit 19 Installation The Piccolo–XR unit can be attached to any vertical or horizontal surface using screws. Before mounting the Piccolo– XR, verify that sufficient clearance is left around the unit. Allow 8" (20 cm) clearance off the bottom of the Piccolo–XR case for the user cable and 6.3" (16 cm) off the top of the unit for the flexible antenna. Piccolo–XR Screw Mounting Options Mount the Piccolo–XR on a vertical surface as follows: Secure the unit to any vertical surface using one 0.35" (9 mm) maximum head screw. Use the mounting hole marked A in Figure 14 to attach it to the mounting surface. See Figure 15 B. Mount the Piccolo–XR on a horizontal surface as follows: Secure the unit to any horizontal surface using two 0.35" (9 mm) maximum head screws. Use the mounting holes marked B and C in Figure 14 to attach it to the mounting surface. See Figure 15 A. Mount the Piccolo–XR on a wide plane as follows: Secure the unit to any plane using three 0.35" (9 mm) maximum head screws. Use all three mounting hole marked A, B and C in Figure 14 to attach it to the mounting surface. See Figure 15 C. 20 Installation 54 mm 3x 4. 75 98mm 49mm Figure 14 Piccolo–XR Mounting Screw holes – Back View Figure 15 Piccolo–XR Mounting Options 21 Installation Piccolo–XR Electrical Connections NOTE! Verify that all power connections are made in accordance with the applicable local standards. Wire (1)-Red Wire (2)-Black 1A Fuse User Cable-FKN8199B + - 6 V DC Battery Wire (17)-Yellow I/O's Ground Figure 16 Piccolo–XR Ground and DC Power Connections Piccolo–XR Ground Connections Connect the yellow wire (17) of the FKN8199B user cable to the PGND, as shown in Figure 16. 22 Installation Power Connections Caution The unit must be powered by a limited power source (6V DC) in accordance with standard UL/IEC 60950-1. See Power in Appendix A below. The Piccolo–XR is powered by an external 6V DC battery source. Use the FKN8199B cable to connect the Piccolo–XR to an external battery. Connect Wire #1 (red) to the positive (+) pole of the battery through a 1A fuse (not supplied) and wire #2 (black) to the battery negative (–) pole. See Figure 16. I/O Connections The Piccolo–XR RTU can control up to four DC Latch Solenoids. The solenoid operating voltage can vary in the range of +9 to +20V DC (defined by the site configuration definition in the DIOS Service Toolkit). The Piccolo–XR also responds to back indication signals from a maximum of eight different field input sensors. The available I/O module options are as follows: 1 DI / 1 DO 2 DI / 2 DO 4 DI / 4 DO 7 DI / 1DO 8 DI / 0DO 23 Installation User Cable-FKN8199B Solenoids Output Common Wire (9) Gray Sensors Input Common Wire (6) Green Figure 17 Piccolo–XR I/O Connections NOTE! 24 For proper operation, the Piccolo–XR unit must be connected either to a flexible antenna or to a pole antenna. See Appendix C for antenna installation details. Installation Table 1: Pin assignment of the Piccolo–XR user cable (FKN8199B) Connector PIN No COLOR DESCRIPTION Red Battery 6V (+) Black Battery 6V (–) Brown Solenoid 2 Orange Input 4 White Input 6 Green Input Common * Blue Solenoid 3 Violet Solenoid 4 Gray Solenoid Common* 10 Pink Solenoid 1 11 Light Green Input 1 12 Black/White Input 2 13 Brown/White Input 3 14 Red/White Input 5 15 Orange/White Input 7 16 Green/White Input 8 17 Yellow PGND (Chassis)* Note! The Input Common, Output Common and Ground are INDEPENDENT. 25 Installation Table 2: Pin assignment of the Piccolo–XR user cable (FKN8199B) Connector DESCRIPTION PIN No COLOR Input 1 11 Light Green Input 2 12 Black/White Input 3 13 Brown/White Input 4 Orange Input 5 14 Red/White Input 6 White Input 7 15 Orange/White Input 8 16 Green/White Input Common Green Solenoid 1 10 Pink Solenoid 2 Brown Solenoid 3 Blue Solenoid 4 Violet Solenoid Common Gray Battery 6V (+) Red Battery 6V (–) Black PGND (Chassis) 17 Yellow 26 THE DIOS PIU AND PICCOLO-XR UNITS PIU Overview The PIU unit (see Figure 18) is comprised of the following: • Internal radio interfaces and a radio modem • A logic board • Communication ports LEDs 24V AC PGND/ RS485 Pwr IN DC Switch Adaptor RS232 Port Figure 18 PIU Unit General View 27 The DIOS PIU and Piccolo-XR Units DC Power In Figure 19 PIU Unit DC Power Connection– Rear View PIU Communication Ports The PIU has four ports: NOTE! Only one of the two RS ports (232 and 485) can be operated at a time, i.e. they do not operate together. 28 • RS485: Communication between multiple PIU units and the FU. • RS232: Communication between the PIU and the FU; Configuration Port (unit programming and monitoring). • Adapter port: Communication with and programming the Piccolo-XR units. • Internal Radio interface: internal DPSK modem. The DIOS PIU and Piccolo-XR Units PIU Connectors The PIU connectors (see Figure 18): • RS232 (RJ45, 8 pin) • RS485 (RJ10, 4 pin) • Adapter port (RJ10, 4 pin) • PGND And Power Switch (TB 3 pin) • 24 V AC PWR IN (2 pin) • 6, 9, 12 V DC Battery Input (2 pin) PIU LED Operation Three software programmable LED indicators are located on the PIU enclosure (see Figure 18). These indicators can be used for diagnostics purposes. • Radio TX/RX (RED): ON – a valid frame is received by the internal DPSK modem or the PIU transmits a frame. • RS232/RS485 RX/TX (ORANGE): ON – a valid frame is received or transmitted through the RS232/RS485 port (UART1). • Adapter port TX/RX (GREEN): ON – a valid frame is received or transmitted through the adapter port (UART2), or the Radio is being programmed. 29 The DIOS PIU and Piccolo-XR Units PIU Adapter Operation The PIU can be used as an adapter to perform the following functions: • Communicating with the Piccolo–XR for configuration, monitoring or hardware test. • Downloading new software to a Piccolo–XR unit. • Downloading new software to a PIU unit. Communicating With a Piccolo–XR Unit 1. Connect the PIU adapter RS232 port to the computer with the FTN6597B cable (see Figure 20). 2. Connect the PIU adapter unit to an external 12VDC battery or to an internal 9V battery. (See page 12 for power options). IMPORTANT: Ensure that there is a 20 cm safety distance between the PIU adapter unit and the user’s body when connecting the battery. 3. Use the Distributed I/O Service Toolkit to turn off the radio’s power. 4. Connect the Piccolo–XR unit to an external 6VDC power source. (See Power Connections on page 23.) 5. Use the P5 connector (communication) of the FKN8171B cable to connect the Piccolo–XR unit to the Adapter port of the PIU unit. 6. Use the Distributed I/O Service Toolkit to configure and monitor the Piccolo–XR or to test its hardware. For additional information, please refer to the online help of the DIOS Service Toolkit. 30 The DIOS PIU and Piccolo-XR Units Piccolo-XR + - PIU Adapter + - P5 P4 Communication Cable Toolkit PC RS232 RS232 To PC Connectors GND RS485 Adapter To Piccolo XR Figure 20 PIU Adapter – Piccolo–XR Communication Mode Connections NOTE! The grounding connector is also used as an ON/OFF switch, and the unit cannot be powered on without connecting it. (See Figure 9.) 31 The DIOS PIU and Piccolo-XR Units Downloading new software to a Piccolo–XR unit 1. Connect the PIU adapter RS232 port to the computer using the FTN6597B cable (see Figure 21). 2. Connect the PIU adapter unit to an external 12VDC battery or to an internal 9V battery. (See page 12 for power options). 3. Connect the Piccolo–XR unit to an external 6 V DC power source. (See Power Connections on page 23.) 4. Use the P4 connector (programming) of the FKN8171B cable to connect the Piccolo–XR unit to the Adapter port of the PIU unit. 5. Use the Distributed I/O Service Toolkit Downloader. For additional information, please refer to the online help of the DIOS Service Toolkit. Piccolo-XR + - PIU Adapter + - P4 P5 Programming Cable Toolkit PC RS232 RS232 To PC Connectors GND RS485 Adapter To Piccolo XR Figure 21 PIU Adapter – Piccolo–XR Downloading Mode Connections NOTE! The grounding connector is also used as an ON/OFF switch, and the unit cannot be powered on without connecting it. (See Figure 9.) 32 The DIOS PIU and Piccolo-XR Units Communicating with a PIU unit 1. Connect the PIU unit RS232 port to the computer with the FTN6597B cable (see Figure 22). 2. Connect the PIU unit to an external 12VDC battery or to an internal 9V battery. (See page 12 for power options.) 3. Use the Distributed I/O Service Toolkit for configuration, monitoring or hardware test. For additional information, please refer to the online help of the DIOS Service Toolkit. PIU +- Toolkit PC RS232 RS232 To PC Connectors GND RS485 Adapter Figure 22 PIU Adapter – PC Communication Connections NOTE! The grounding connector is also used as an ON/OFF switch, and the unit cannot be powered on without connecting it. (See Figure 9.) 33 The DIOS PIU and Piccolo-XR Units Downloading new software to a PIU 1. Connect the PIU adapter RS232 port to the computer with the FTN6597B cable (see Figure 23). 2. Connect the PIU adapter to an external 12VDC battery or to an internal 9V battery. (See page 12 for power options). 3. Connect the PIU unit to an external 12VDC battery or to an internal 9V battery. (See page 12 for power options.) 4. Use the FKN8203B cable to connect the Adapter port of the PIU adapter to the RS232 connector of the PIU unit to be programmed. 5. Use the Distributed I/O Service Toolkit Downloader. For additional information, please refer to the online help of the DIOS Service Toolkit. PIU unit + - PIU Adapter + - Programming Cable Toolkit PC RS232 Connectors GND RS485 Connectors GND RS485 Adapter RS232 To PC Adapter To RS232 of Programmed PIU RS232 To Adapter of Programming PIU Figure 23 PIU Adapter Programming Mode Connections NOTE! The grounding connector is also used as an ON/OFF switch, and the unit cannot be powered on without connecting it. (See Figure 9.) 34 The DIOS PIU and Piccolo-XR Units Piccolo-XR Overview The Piccolo -XR Remote Terminal Unit (RTU) is comprised of: ¾ Logic board, which includes: • I/Os • Radio interface • Power supplies • Communication ports ¾ Radio 26 pin Connector Figure 24 Piccolo-XR Unit Piccolo-XR Communication Ports The Piccolo-XR has three ports: • Programming port: for downloading SW. • UART Port: Configuration Port (for programming and monitoring the unit) • Internal Radio interface: internal DPSK modem. 35 The DIOS PIU and Piccolo-XR Units Piccolo-XR Connector The Piccolo -XR has one D-type 26 pin connector (see Figure 24). See Table 1 and Table 2 on pages 25–26 for more information Input/Output options A variety of I/O options is available for use with the Piccolo-XR, increasing the system flexibility. The available Piccolo-XR I/O options are: • 1 DI / 1 DO • 2 DI / 2 DO • 4 DI / 4 DO • 7 DI / 1DO • 8 DI / 0DO For option numbers, see Appendix B below. 36 APPENDIX A: PIU and PICCOLO-XR SPECIFICATIONS PIU Specifications Environmental Operating Temperature -30 C to +60 C (-22 F to +140 F) Storage Temperature -40 C to +85 C (-40 F to + 185 F) Relative Operating Humidity Operating Altitude 0 to 95% without condensation @ +50 C (122 F) -400 m to +4000 m (-1300 ft to 13,000 ft) above sea level Mechanical Dimensions 126x108x42.6 mm 1 mm (4.96"x4.25"x1.67") Weight 253 gr 25 gr (0.56 lb 0.06 lb) User Connection RS232 Adapter port RS485 PGND and DC switch 24 VAC 6V, 9V, 12V DC BAT IN (RJ45) (RJ10) (RJ10) (TB 3 PIN) (Molex header 2 PIN) (Straight 2 PIN) 37 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS PIU Board Communication Ports RS232 Serial RS-232 RS485 Multi Drop 2 Wire Adapter Serial interface between PIU as adapter and PICCOLO–XR (UART levels) Boot-Strap Software programming port Internal Radio RF Frequency UHF 450–470 MHz (actually 450.0125-469.9875) OR UHF 430-450 MHz (actually 430.0125-449.9875) * ** (Service Toolkit programmable) Duty Cycle ratio < 10% (relative to a 1 hour period for ISM band only) Channel spacing 12.5 KHz Internal Modem DPSK 1200 TX RF Low power mode: 8 – 12 mW @+25 C (+77 F) (10 mW typical) 5 – 16.3 mW @–30 C - +60 C (-22 F to 140 F) TX RF High power mode: 80 – 108 mW @+25 C (+77 F) (100 mW typical) 50 – 108 mW @–30 C - +60 C Frequency Error: 1.5 ppm Includes unlicensed ISM (intended for industrial, scientific and medical purposes) band: Center frequency: 433.92 MHz, Frequency range: 433.05–434.79 MHz (actually 433.0625-434.7875 MHz) in Region 1. See Unlicensed Frequency Restrictions below. ** Not including 443.95 MHz and 444.8625 MHz. 38 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS TX deviation: 2KHz 15% RX BER LEDs BER<1% (See Note 5 on p. 41.) Red, Orange, Green (SW Programmable) Power Input Voltage External Source (DC Power In) 6.00 to 16.00 VDC e.g. lead acid battery or solar panel, typically used in irrigation systems. External Source (24V ~ IN) 24VAC±20%, typically from transformer to 110VAC or 220VAC. Power Modes Adapter Mode (Using the internal 9 V battery) Normal Operation 1 – 5 mA (See Note 4 on p. 41.) Sleep Mode LPM0 LPM3 250 – 400 μA (See Note 1 on p. 41.) 140 – 290 μA (See Note 1 on p. 41.) Power Fail Mode LPM3 270 – 850 μA (See Note 3 on p. 41.) 39 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS PIU Mode (Using a 12 V or 6 V external power source) Radio Transmission (TX power-10 mW) 25 – 40 mA 65 – 90 mA (PWR IN =14 V) (PWR IN = 6 V) (TX power-100 mW) 30 – 65 mA 85 – 135 mA (PWR IN =14 V) (PWR IN = 6 V) 13 – 18 mA 30 – 38 mA (PWR IN =14 V) (PWR IN = 6 V) Standby current Radio Receives Sleep Mode LPM0 LPM3 200 – 320 μA (See Note 2 on p. 41.) 130 – 250 μA (See Note 2 on p. 41.) Power Monitors Power OK Voltage (Service Toolkit Adjustable Default = 12 V DC) 200 mV LOW Power Voltage (Service Toolkit Adjustable Default = 11.2 V DC) 200 mV Very Low Battery (Service Toolkit Adjustable Default = 10.8 V DC) 200 mV Reverse Input Voltage Connection 40 Protected APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Note 1: Power In = 9 V DC (Adapter), RS232 = shutdown, RS485 = disable, Radio (On Board Circuits) = off, internal Radio is off. RS232 cable connected. Note 2: Power Supply = 14 V DC (PIU), RS232 = shutdown, RS485 = disable, Radio (On Board Circuits) = off, internal Radio is off. RS232 cable connected. Note 3: Power In = 5.4 V DC (Power fail), RS232 = shutdown, RS485 = disable, Radio (On Board Circuits) = off, internal Radio is off. RS232 cable connected. Note 4: Power In = 9 V DC (Adapter), RS232 = auto shutdown, RS485 = disable, Radio (On Board Circuits) = off, internal Radio is off. RS232 cable connected. Note 5: Apply 1.2 KHz FM signal with 2 KHz Deviation, Sensitivity @–110 dBm to the radio, and read BER. At extreme temperatures apply –104 dBm. PICCOLO XR Specifications Environmental Operating Temperature -30 C to +60 C (-22 F to +140 F) Storage Temperature -40 C to +85 C (-40 F to + 185 F) Relative Operating Humidity 0 to 95% without condensation @ +50 C (122 F) Operating Altitude -400 m to +4000 m (-1300 ft to 13,000 ft) above sea level Housing IP66 41 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Mechanical Dimensions 127x117x41.5 mm 1 mm (5.00"x4.60"x1.63") Weight 240 gr 24 gr (0.54 lb 0.05 lb) User Connection 17 pin User Cable (26 pin D-type connector) Wire Gauge 22 AWG PICCOLO XR Board INPUTS: Number of Inputs Modularity: 1, 2, 4, 7, 8 Dry contact Input Ratings Open: > 45 k (OFF) Closed: < 6 k (ON) Minimum pulse width 100 msec Maximum pulse rate 7200 pulses per hour OUTPUTS: Number of Outputs Modularity: 1, 2, 4 Output Drive Voltage 9 - 20 Volts (± 10%) (Service Toolkit Adjustable)2200 µF capacitor Output Short Circuit Protection >5 A Communication Ports 42 UART 1 port Serial port uart levels (Async.) UART 2 port Serial port UART levels (Async.) Bootstrap Port Software programming port APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Internal Radio RF Frequency UHF 450–470 MHz or UHF 430-450 MHz * ** (Service Toolkit programmable) Duty Cycle ratio < 10% (relative to a 1 hour period for ISM band only) Channel spacing 12.5 KHz Internal Modem DPSK 1200 TX RF Low power mode: 8 – 12 mW @+25 C (+77 F) (10 mW typical) 5 – 16.3 mW @–30 C - +60 C (-22 F to 140 F) TX RF High power mode: 80 – 108 mW @+25 C (+77 F) (100 mW typical) 50 – 108 mW @–30 C - +60 C Frequency Error 1.5 ppm TX deviation 2KHz 15% RX BER BER<1% (See Note 10 on p. 44.) Power Input Voltage External Battery Source 4 to 7.8 V DC (See Note 11 p. 45.) Power Consumption (6 V battery operation) Normal Operating Mode: Includes unlicensed ISM (intended for industrial, scientific and medical purposes) band: Center frequency: 433.92 MHz, Frequency range: 433.05–434.79 MHz (actually 433.0625-434.7875 MHz) in Region 1. See Unlicensed Frequency Restrictions below. ** Not including 443.95 MHz and 444.8625 MHz. 43 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Radio Transmission Radio Off 1.2 – 1.5 mA (See Notes 6, 7 p. 44.) (TX power-10mW) 65 – 90 mA (TX power-100mW) 100 – 150 mA (See Notes 8, 9 p. 44.) Radio Receives 30 – 40 mA (See Notes 8, 9 p. 44.) (See Notes 8, 9 p. 44.) Sleep Mode LPM0 LPM3 Power Fail Mode LPM3 190 – 250 μA (See Note 7 p. 44.) 40 – 65 μA (See Note 7 p. 44.) 40 – 70 μA (See Note 6 p. 44.) Power Monitors Power In Report 200 mV Power OK Voltage Service Toolkit Adjustable Default = 6 V DC 200 mV Low Power Voltage Service Toolkit Adjustable Default = 5 V DC 200 mV Very Low Battery Service Toolkit Adjustable Default = 4.8 V DC 200 mV Reverse Input Voltage Connection Protected Note 6: Power In = 4 V DC, Radio (On Board Circuits) = Off, internal Radio is off. Note 7: Power In = 7.8 V DC, Radio (On Board Circuits) = Off, internal Radio is off. Note 8: Power In = 5.5 V DC, Radio (On Board Circuits) = On, internal Radio is On. Note 9: Power In = 7.8 V DC, Radio (On Board Circuits) = On, internal Radio is On. Note 10: Apply 1.2 KHz FM signal with 2 KHz Deviation, Sensitivity @-110 dBm to the radio, and read BER. At extreme temperatures apply -104 dBm. 44 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Note 11: For radio functionality external Power In minimum voltage=5 V. Unlicensed Frequency Restrictions (For UHF 430-450 MHz radio only) When using a frequency in the unlicensed ISM range (433.0625-434.7875 MHz, not including 443.95 MHz and 444.8625 MHz), certain regulatory restrictions apply: Maximum transmit power 10mW (See Note 12 below.) Maximum transmission time 1 sec (See Note 13 below.) Channel occupation duty cycle (total transmit time in any hour) 10% per hour (360 seconds) (See Note 14 below.) Transmission Limited to quiet channel (See Note 15 below. Override Not allowed When Piccolo XR / PIU units are ordered in the unlicensed ISM range (433.0625 - 434.7875 MHz), the radio will be shipped after being programmed to 10 mW output power. Note 12: Please note that due to the lower transmission power, the distance between the Piccolo and the PIU is shorter than the distance when using a licensed frequency with 100 mW transmission power. Note 13: The current consumption of the Piccolo will increase due to the fact that the Maximum transmission time is reduced and therefore the Piccolo should wake up more frequently. Note 14: The maximum number of transmissions from the PIU/Piccolo is limited to 360 per hour. When this number is exceeded, the PIU/Piccolo will stop transmitting until the current hour has elapsed. Note 15: The PIU/Piccolo will not transmit on a busy channel. Verify that the frequency you choose in the band is not continually busy. 45 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Regulatory Standards US and Canada Grant of Equipment Authorization IMPORTANT: Unauthorized repairs or modifications could result in permanent damage to the equipment and void your warranty and your authority to operate this device under Part 15 of the FCC Rules. FCC Grant of Equipment Authorization FCC ID: AZ489FT4888 FCC ID: AZ489FT4871 Industry Canada Grant of Equipment Authorization ID: 109U-89FT4888 ID: 109U-89FT4871 This Class B digital apparatus complies with Canadian ICES003. Radio Network Freq Band Rated Power FM UHF 430-450MHz 100mW FM UHF 450-470MHz 100mW FCC INTERFERENCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. For detailed product safety and RF exposure, refer to the Product Safety and RF Energy Exposure Booklet for PIU and 46 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Piccolo XR Units, Motorola publication no. 6802974C70, which is distributed with the devices. European Union Notification The CE mark is the official marking required by the European Community for all Electric and Electronic equipment that will be sold, or put into service for the first time, anywhere in the European community. It proves to the buyer or user that this product fulfills all essential safety and environmental requirements as they are defined in the European Directives. The product approved for unlicensed band 433.05-434.79 mark. Mhz is marked with the The product approved for licensed band 430-450 MHz marked with the following CE marks, , carries the alert symbol to denote that the product band range of 430-450 MHz is not harmonized in all EU member states. Equipment Disposal Waste (Disposal) of Electronic and Electric Equipment Please do not dispose of Electronic and Electric Equipment or Electronic and Electric Accessories with your household waste. In some countries or regions, collection systems have been set up to handle waste of electrical and electronic equipment. In European Union countries, please contact your local equipment supplier representative or service center for information about the waste collection system in your country. 47 APPENDIX A: PIU AND PICCOLO-XR SPECIFICATIONS Conformity for RoHS Compliance This Motorola product is in compliance with the essential requirements and other relevant provisions of Directive 2002/95/EC, Restriction of the use of certain Hazardous Substances (RoHS) in electrical and electronic equipment. 48 APPENDIX B: MODELS and ACCESSORIES General The following tables describe the available models, options and accessories. ∗ DIOS Models Model Piccolo Interface Unit (PIU) F4604B Piccolo–XR DC F4614B PIU Options Option ADD: RS-485 Option (indoor) V440AD ADD: RS-232 Cable 3 m V666AA ADD: Antenna for PIU, 450-470 MHz V208AJ ADD: Antenna for PIU, 430-450 MHz V208AL ADD: PIU Adapter V345AM ADD: PIU DIOS Application V377AD INT: 12.5 KHz UHF Radio, 450–470 MHz V347CT/ FLE6036C INT: 12.5 KHz UHF Radio, 430–450 MHz ∗ ** V347CU/ FLE5532A Includes unlicensed ISM (intended for industrial, scientific and medical purposes) band: Center frequency: 433.92 MHz, Frequency range: 433.05–434.79 MHz (actually 433.0625-434.7875 MHz)in Region 1. ** Not including 443.95 MHz and 444.8625 MHz. 49 Appendix B: Models and Accessories Piccolo-XR Options Option ADD: 1 DI / 1DO Option V608AE ADD: 2 DI / 2DO Option V379AK ADD: 4 DI / 4DO Option V118AJ ADD: 7 DI / 1 DO Option V115AN ADD: 8 DI / 0 DO V508AF ADD: Antenna for Piccolo–XR, 450-470 MHz V208AH ADD: Antenna for Piccolo–XR, 430-450 MHz V208AK INT: 12.5 KHz UHF Radio, 450–470 MHz V347CT/ FLE6036C INT: 12.5 KHz UHF Radio, 430–450 MHz ∗ ** V347CU/ FLE5532A Accessories Kit number TEC Programming & Monitoring Cable (26 pin) FKN8171B Pole Antenna Kit (SMA TO SMA) FAE5534B Pole Antenna Kit (SMA TO N-TYPE) FLN3373B 50 APPENDIX C: ANTENNA General The PIU and Piccolo–XR units can be connected either to a flexible or to a pole antenna. The antenna connector (see Figure 25), located at the top of the unit, is used for both antenna types. PIU Antenna SMA Connector Piccolo - XR Antenna SMA Connector Figure 25 PIU and Piccolo–XR Antenna Connectors Flexible Antenna Specifications Frequency Range: Polarization: Nominal Impedance: VSWR: Power Rating Temperature Range: UHF Vertical 50 ohms 1.5:1 max at resonance 50 watts -40ºC to +85ºC 51 Appendix C: Antenna Pole Antenna The pole antenna installation must comply with the following requirements in order to ensure optimal performance and guarantee that human exposure to radio frequency electromagnetic energy is within the guidelines set forth by the applicable local regulations. The antenna must be mounted outdoors, preferably on a tower, if possible. Building mounted antennas must be located on the building roof. All fixed site antenna installations, including the installation of this pole antenna, require that, under the responsibility of the licensee, the installation site be managed in accordance with the applicable regulatory requirements. This may require taking additional compliance actions such as signage and site access restrictions in order to ensure that human exposure limits are not exceeded. Figure 26 PIU/Piccolo–XR Pole Antenna 52 Appendix C: Antenna Pole Antenna installation SMA to SMA option Antenna Antenna Support Rubber Washer Nut Lock Washer SMA Connector Adjustable Straps SMA to SMA Antenna Cable Rubber Sleeve SMA Connector Figure 27 SMA to SMA type PIU/Piccolo–XR Pole Antenna 1. Connect a flexible antenna to the antenna support plate using rubber washers, lock washer and a nut (see Figure 27). 2. Connect one end of the SMA cable to the antenna connection. 3. Connect the other end to the PIU/Piccolo–XR. 53 Appendix C: Antenna SMA TO N-TYPE Antenna Antenna Support Rubber Washer Nut Adjustable Straps Nut Lock Washer SMA Connector N-Type Connector SMA to N-Type Antenna Cable N-Type Washer Figure 28 SMA to N-Type Pole Antenna 1. Connect a flexible antenna to the antenna support plate using rubber washers, lock washer and a nut (see Figure 28). 2. Connect the SMA end of the cable to the antenna connection. 3. Connect the N Type end to the PIU/Piccolo–XR. 54 Appendix C: Antenna Pole Antenna Dimension 83mm 200mm 91.5mm 174mm Figure 29 shows recommended dimensions for a supporting plate for the pole antenna. 200mm 270mm Figure 29 PIU/Piccolo–XR Pole Antenna Supporting Plate Dimensions 55 Appendix C: Antenna This page left intentionally blank. 56 APPENDIX D: PIU/PICCOLO–XR MOUNTING TEMPLATES Use the following template for PIU wall mounting. 3.26" 82.7mm Figure 30 PIU Wall Mounting Template (Full Size) Figure 31 PIU Back 57 Appendix D: PIU/Piccolo – XR Mounting Templates Figure 32 Piccolo–XR Mounting Template (Full Size) 58 1.93" 49mm 2.126" 54mm 3.86" 98mm The following is a template that can be used for mounting the Piccolo–XR unit. MOTOROLA and the Stylized M Logo are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their respective owners. Copyright © 2009 Motorola All Rights Reserved 6802974C40-R @6802974C40@ August 2009
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Motorola Create Date : 2009:06:03 15:40:42+03:00 Modify Date : 2009:07:23 15:25:08+03:00 Tagged PDF : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2009:07:23 15:25:08+03:00 Creator Tool : Acrobat PDFMaker 8.1 for Word Format : application/pdf Title : Distributed I/O System Owner's Manual Creator : Motorola Document ID : uuid:bd30d2ef-45a6-41e8-af60-8d3107959184 Instance ID : uuid:7a3ca47c-cba8-491b-87de-b3bde0b8284a Producer : Acrobat Distiller 8.1.0 (Windows) Page Mode : UseOutlines Page Count : 68EXIF Metadata provided by EXIF.tools