Muratec Automation VEHICLECMC CMC User Manual
Muratec Automation Co.,LTD CMC Users Manual
Users Manual
Communication unit CMC Operation Manual ※Operation Manual for Communication unit CMC Model: CMC(CMC-BC,CMC-BM,CMC-TR) 1st edition January 31, 2010 Control Design Section, Semiconductor Engineering Dept. MURATEC AUTOMATION CO., LTD. Rev. Approved Rev. Rev. Rev.1 2011/03/03 Change FCC ID Doc. No. Muratec Automation Co., Ltd. Checked Prepared Engineerring Dept Development Dept Development Dept. 2011.2.10 2011.2.1 2011.01.31 Kawashima Onishi M.KURODA Kawashima Onishi Kuroda YSDA-3495△1 < Revision History > Ver. Date 2011/01/31 2011/03/03 Page Description The first edition. 3,8,16 Change FCC ID Muratec Automation Co., Ltd. 〈Contents〉 〉 1. 2. Introduction ................................................................................................................................ 3 1.1. Construction of the documents .......................................................................................... 3 1.2. Application.......................................................................................................................... 3 1.3. Related Rules, Laws .......................................................................................................... 3 1.4. Abbreviations...................................................................................................................... 3 Safety......................................................................................................................................... 4 2.1. 3. 4. 5. Outline of Communication Unit CMC ........................................................................................ 8 3.1. Overview............................................................................................................................. 8 3.2. CMC configuration.............................................................................................................. 8 3.3. Function of each unit........................................................................................................ 11 3.4. The Block Diagram of CMC ............................................................................................. 12 3.5. Outline form of CMC......................................................................................................... 13 3.6. FCC standard ................................................................................................................... 16 CMC-BC Board Setting ........................................................................................................... 17 4.1. CMC-BC Board Check ..................................................................................................... 17 4.2. NBV-BC Printed Circuit Board DIP Switch Settings ........................................................ 18 CMC-BM Board Setting ........................................................................................................... 22 5.1. 6. 7. 8. Alert Boxes ......................................................................................................................... 4 CMC-BM Board Check..................................................................................................... 22 Communications Adjustment................................................................................................... 24 6.1. Prerequisites .................................................................................................................... 24 6.2. Check before Vehicle Start-Up (Track Power Panel is OFF) .......................................... 24 6.3. Check before Vehicle Start-Up (Track Power Panel is ON) ............................................ 25 6.4. Check and Adjustments of each Level of CMC-BM ........................................................ 26 Specification ............................................................................................................................ 32 7.1. CMC-BC (Communication Modem Controller :Base Controller).................................. 32 7.2. CMC-BM(Communication Modem Controller :Base Modem) ...................................... 32 7.3. CMC-TR(Communication Modem Controller :TRansformer)....................................... 33 Error process ........................................................................................................................... 34 Muratec Automation Co., Ltd. 1. Introduction 1.1. Construction of the documents The documents of the communication units CMC are as follows. Kind of document Name of the document # of documents Operation manual Communication unit CMC Operation Manual YSDA-3495 Installation manual Communication unit CMC Installation Manual YSDA-3496 Block Diagrams Communication unit CMC Block Diagrams YSDA-3493 1.2. Application This document describes the operation of communication unit for transport system, OHT, OHS, etc. 1.3. Related Rules, Laws (1) FCC Part15 Subpart C: 2010 FCC ID : ZBQVEHICLECMC (2) FCC Part15 Subpart B: 2010 Class A 1.4. Abbreviations (1) CMC (2) CMC-BM (3) CMC-BC (4) CMC-TR (5) COM Communication Modem Controller Communication Modem Controller :Base Modem Communication Modem Controller :Base Controller Communication Modem Controller :TRansformer COmmunication Modem Muratec Automation Co., Ltd. 2. Safety 2.1. Alert Boxes 2.1.1.General (1) Read and understand fully this manual and attached documents before operating the products. (2) Engage specialists in electrical and mechanical works. (3) Don’t improve the product by yourselves. (4) Be sufficiently proficient with the equipment, the relevant safety knowledge and the precautions prior to using this product. In the content of this “Safety Precautions ”, items which need to be alert shall be classified into “DANGER”, “WARNING” and ”CAUTION”. 2.1.2.Definitions of DANGER, WARNING and CAUTION DANGER: An imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: A potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. [Note 1] Medium degree of injuries or light injuries refers to injuries, e.g., burns and electric shock, which do not require hospitalization of or prolonged hospital visit by the victims. As material losses refers to expanded losses pertaining to the damage of property and equipment. [Note 2] Depending on the situation, the events described under “WARNING” may also result in severe outcome. In either case, make sure that the advice is followed. After reading, make sure this information shall be kept at places where it can always be read by users. Muratec Automation Co., Ltd. 2.1.3.Precautions on use DANGER Follow the following advice strictly to avoid electric shock or burns. 1. Don’t enter the operation area of the vehicle. Work on the ladder may collide to the vehicle and may cause injury. 2. Don’t touch the vehicle on the track when Power Supply Panel output the power. 3. Don’t touch the moving parts of the vehicle while it is in operation. Doing so may cause injuries. 4. Only those who received training for maintenance and teaching can do maintenance and teaching. 5. Make sure the earth terminals for the relate equipment shall be grounded. Not doing so may cause electric shock. 6. Don’t break the cable, impose excessive stress, place heavy weights, or pinch it between items. Doing so may cause electric shock. WARNING 1. Don’t use the equipment at locations where water, corrosive atmosphere, or flammable gas is present, or beside flammable items. Doing so may cause life and fails. Muratec Automation Co., Ltd. 2.1.4.Storage PROHIBITION 1. Don’t store the equipment at locations where it is subject to rain, ater hazardous gas or liquid. MANDATORY ACTION 1. Store the equipment at locations in not subjected to sunshine. Store it at predetermined relative humidity and temperature. 0 degrees C. - 50 degrees C., 90% RH and below, no dew. 2.1.5.Installation WARNING 1. Don’t climb on top of the equipment or place heavy items on it. Doing so may cause injuries. 2. Don’t block the air inlet and outlet ports or allow foreign particles to enter them. Doing so may cause fire. 3. Follow the installation direction strictly as it is so design for dissipation of heat, fails or fire. 4. Don’t hit the equipment with strong impact. Doing so may cause equipment fails. Muratec Automation Co., Ltd. 2.1.6.Maintenance and Inspection PROHIBITION 1. Don’t engage non-specialist technicians to disassemble and repair the equipment. DANGER 1. Before servicing CMC-BC,CMC-BM,CMC-TR,always shut off the power supply. If the communication signals are overlaid onto the non-conductive power line, also shut off the power source of the non-conductive power line before starting maintenance on CMC-BM and CMC-TR. Not doing so may cause electric shock. Muratec Automation Co., Ltd. 3. Outline of Communication Unit CMC 3.1. Overview The communication unit CMC (Communication Modem Controller) is used for the communication between the ground Vehicle Controller and several vehicles in the conveyance system made by MURATEC AUTOMATION CO., LTD. The communication signals are overlaid onto the power line for non-conductive power supply to the vehicles. In some systems, a separate signal lines may be used. CMC meet the requirements of FCC Part15 Subpart C. The FCC ID is as follows. FCC ID of CMC: ZBQVEHICLECMC It modulates the signals sent from the Vehicle controller and transmits the modulated signals to the vehicles. It also demodulates the signals sent from the vehicles and transmits them to the Vehicle controller. The communication method in use is FSK ( frequency shift keying). The communication frequencies are as follows. From (1) CMC → (2) Vehicles → to Frequency Vehicles: 300.33 kHz CMC: 353.25 kHz 3.2. CMC configuration Figures 1 to 3 show the basic configuration of CMC. CMC consists of the following units. (1)CMC-BC (Communication Modem Controller :Base Controller) Printed circuit NBV-BC2 DC power supply (5V) Case (2)CMC-BM (Communication Modem Controller :Base Modem) Printed circuit BV-BM3 DC power supply (24V) Case (3)CMC-TR(Communication Modem Controller :TRansformer) Communication transformer(transmission, reception) Case Muratec Automation Co., Ltd. Power Supply Line (Parallel Wire) TX CMCCMC-TR CMCCMC-BM Digital Signal line with shield RX Modem TX PCB BV-BM3 RX CPU PCB NBV-BC2 Analog Signal line 100V or 200V 50/60Hz Vehicle Track CMCCMC-BC Digital Signal line with shield Power Supply Unit Vehicle Controller Power Supply Panel Fig. 1 Basic configuration of CMC CMCCMC-BM CMCCMC-TR Ferrite Core Digital Signal line with shield TX PCB BV-BM3 RX Power Supply Line 100V or 200V 50/60Hz (Parallel Wire) Analog Signal line CMCCMC-BM Ferrite Core Digital Signal line with shield CMCCMC-TR TX TX PCB BV-BM3 Output: 8-Port maximum RX RX Modem Analog Signal line PCB Track 100V or 200V 50/60Hz NBV-BC2 CPU CMCCMC-BC Vehicle Digital Signal line with shield Power Supply Unit Vehicle Controller Power Supply Panel Fig. 2 Modified CMC configuration Example 1 Muratec Automation Co., Ltd. CMCCMC-TR CMCCMC-BM Ferrite PCB TX Core BV-BM3 RX 100V or 200V 50/60Hz CMCCMC-BM CMCCMC-TR 100V or 200V 50/60Hz Ferrite PCB Output: 8-Port maximum TX Core BV-BM3 RX 100V or 200V 50/60Hz PCB NBV-BC2 CMCCMC-TR CMCCMC-BM CMCCMC-BC Ferrite Digital Signal line with shield Digital Signal line with shield PCB TX Core BV-BM3 RX 100V or 200V 50/60Hz Power Supply Line (Parallel Wire) Analog Signal line CMCCMC-TR CMCCMC-BM Ferrite Digital Signal line with shield PCB Core BV-BM3 TX TX RX RX Output: 8-Port maximum Modem Track Analog Signal line PCB NBV-BC2 100V or 200V 50/60Hz CPU CMCCMC-BC Vehicle Digital Signal line with shield Power Supply Unit Vehicle Controller Power Supply Panel Fig. 3 Modified CMC configuration Example 2 10 Muratec Automation Co., Ltd. 3.3. Function of each unit 3.3.1.CMC-BC (Communication Modem Controller :Base Controller) This is an interface unit to handle the signals from/to the vehicle controller. It also serves as the multiplexer for several CMC-BM units. CMC-BC can work in two different modes, master mode and slave mode. It allows the user to use the multiple units according to the scale of the conveyance system. The CMC-BC unit may vary in its outward form depending on the conveyance system. However, the internal configuration is common. Figure 4 shows the block diagram of CMC-BC. Figure 5 shows the outward form of the CMC-BC’s main printed circuit board NBV-BC. Figure 6 shows for example the outward form of the CMC-BC unit. 3.3.2.CMC-BM(Communication Modem Controller :Base Modem) This is a modem unit to handle the signals from/to several vehicles. It incorporates a driver that modulates the digital signals sent from CMC-BC to analog signals and overlay the converted signals onto the non-conductive power line or signal line. It also demodulates the analog signals sent from the vehicles to digital signals and transmits them to CMC-BC. The CMC-BM unit may vary in its outward form depending on the conveyance system. However, the internal configuration is common. Figure 4 shows the block diagram of CMC-BM. Figure 7 shows the outline form of the CMC-BM’s main printed circuit board BV-BM2. Figure 8 shows for example the outline form of the CMC-BM unit. 3.3.3.CMC-TR(Communication Modem Controller :TRansformer) Transmission transformer overlays the signals from CMC-BM onto the non-conductive power line or signal line. The reception transformer receives the signals from vehicles overlaid in the non-conductive power line or signal line. Figure 9 shows the outer forms of the transformers. 11 Muratec Automation Co., Ltd. 3.4. The Block Diagram of CMC Fig. 4 The block diagram of CMC CMC is a communication unit between a vehicle controller and vehicles. The communication signals modulate current signals of a power line/or signal line . The vehicle controller controls vehicle movement by transmitting and receiving this signal. [CMC-BC] Communication signals from the vehicle controller are transmitted to CMC-BC as RS232C or RS485. When communication signal is “1”, The Modulator of CMC-BC modulates 285.7 kHz FSK signal frequency. When communication signal is “0”, The Modulator of CMC-BC modulates 315.8 kHz FSK signal frequency. The modulation signal is transmitted to CMC-BM through a line driver of RS485.This modulation signals transmit to CMC-BM as RS485. [CMC-BM and CMC-TR] The modulation signal is received from CMC-BC through a line receiver of RS485. TX Amp of CMC-BM is full bridge inverter. The modulation signals are converted into a gate signal of full bridge inverter. The inverter transmits the modulation signal through resonance circuit and CMC-TR. 12 Muratec Automation Co., Ltd. 3.5. Outline form of CMC 3.5.1. CMC-BC (Communication Modem Controller :Base Controller) Fig. 5 Outward form of the CMC-BC’s main printed circuit board NBV-BC2 Fig. 6 For example the outward form of the CMC-BC unit 13 Muratec Automation Co., Ltd. 3.5.2.CMC-BM(Communication Modem Controller :Base Modem) Fig. 7 The outline form of the CMC-BM’s main printed circuit board BV-BM3 Fig. 8 For example the outline form of the CMC-BM unit 14 Muratec Automation Co., Ltd. 3.5.3. CMC-TR(Communication Modem Controller :TRansformer) Fig. 9 The outer forms of the transformers Fig. 10 For example the outline form of the CMC-TR unit 15 Muratec Automation Co., Ltd. 3.6. FCC standard The transmission assembly in the communication unit CMC meets FCC Part15 Subpart C as the intentional radiator. FCC ID of CMC: ZBQVEHICLECMC FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. - Properly shielded and grounded cables and connectors must be used for connection to vehicle controller and CMC-BC in order to meet FCC emission limits. - Properly shielded and grounded cables and connectors must be used for connection to CMC-BM and CMC-BC in order to meet FCC emission limits. - TX transformer of CMC-TR with ferrite core must be used for RF interference suppression. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. [Note.1] The FCC certificate position may vary because different case materials and shapes are adopted for different customers. 16 Muratec Automation Co., Ltd. 4. CMC-BC Board Setting CMC-BC Board Check 4.1. 4.1.1. Purpose Check for short circuit and earth ground fault before energizing CMC-BC board for the safety. 4.1.2. Required Materials • • • Wiring Diagrams, Checklist Multimeter, Phillips-head Screw Driver (+2), Wrench, Tape Measure Vehicle 4.1.3. Tips, Precautions and Prohibited Actions・ Set the barricade with colored-cones and safety bars around the work area. ・ Measure the short-circuit and the earth fault after confirming it has no voltage. ・ Work in the energized status is prohibited. 4.1.4. Procedures A) After confirming that the CMC-BC board’s CPM is OFF (see Fig. 11), check for short circuit and earth ground fault on the secondary side of the CPM. (Make sure you confirm that the AC power voltage is zero V before measuring the resistance. Since the primary side of the CMP is connected to the indicator lamps, short circuit check should show 3 - 4KΩ. The ground fault shall be open.) B) Check for short circuit and earth ground fault on the secondary side of CP1 through CP8. The CPM must be OFF at this time. Both short circuit and earth ground fault checks on the secondary side of CP1 through CP 8 shall indicate open. C) Confirm that all connectors on the NBV-BC printed circuit board are firmly connected. Lock the connecters with connector fastenings. (If any connecter is loose, communications will fail.) D) Firmly insert the 232C cable from the OHVC to CN12 on the NBV-BC printed circuit board. (If loose, communications will fail.) E) Set the NBV-BC P board’s DIP switches (SW 1, 2 and 3) in accordance with provided specifications. (If they are not set, communications will fail.) F) Measure the voltage of primary side of CPM G) After confirming that everything is good, turn ON the circuit breaker on the power distribution panel to energize the CMC-BC board. Hereafter, Work in the energized status is prohibited. 17 Muratec Automation Co., Ltd. Fig. 11 For example the outward form of the CMC-BC unit 4.2. NBV-BC Printed Circuit Board DIP Switch Settings 4.2.1. Purpose Set the station number etc. on site as when it is shipped with the initial settings. 4.2.2. Required Materials • • Connection Diagram, Checklist Precise Driver 4.2.3. Tips, Precautions and Prohibited Actions ・ Appropriate settings are required for an appropriate BC. Otherwise, it will not communicate with. 4.2.4. Procedures A) The settings for the NBV-BC’s DIP-SWs are shown below. Refer to examples 1 through 4 to properly set up the target module. Table. 1 DIPSW-1(Operation Mode) SW Operation Function OFF ON Remarks Master/Slave Switch Slave Master Filter Enable/Disable Switch Enable Disable RS232C/RS485 Switch RS232C RS485 Communications Speed Switch 19.2 Kbps 28.8 Kbps See specifications 18 Muratec Automation Co., Ltd. Available only in Master Table. 2 DIPSW-2(Terminal Resistance Settings) SW Operation Function OFF ON Remarks Terminal Resistance Y/N No Yes Refer to connection Terminal Resistance Y/N No Yes sample Terminal Resistance Y/N No Yes Terminal Resistance Y/N No Yes Table. 3 DIPSW-3(Terminal Resistance Settings) SW Operation Function OFF ON Remarks Terminal Resistance Y/N No Yes Refer to connection Terminal Resistance Y/N No Yes sample Terminal Resistance Y/N No Yes Terminal Resistance Y/N No Yes B) NBV-BC printed circuit board DIP-SW layout and connector layout are shown in the figure below. CN9 CN10 SW3 CN13 SW2 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN8 SW5 SW1 CN12 CN14 SW5 Fig. 12 NBV-BC Board Switch Layout 19 Muratec Automation Co., Ltd. CMC-BC (Single use) OHVC CMC-BC (2 in use) OHVC ※ RS232C CN12 CN9 Master CN13 ※ RS485 Master CN12 CN10 OHVC ※ RS232C RS485 CMC-BC (N in use) CN9 RS485 CN13 CN12 CN10 CN9 Slave 1 CN9 Master CN13 CN10 Slave 1 - Slave (N(N-1) CN10 CN9 CN10 Slave N ※ With RS485 (CN13), set DIPSW1-3 ON CN9 CN10 Fig. 13 NBV-BC Board Connection Table. 4 CMC-BC DIP Switch Settings (Filter “Enable”, communication speed:28.8kbps) DIP SW1 DIP SW2 DIP SW3 Master/ BC SW4 SW5 Slave No. ON OFF No. ON OFF No. ON OFF ○ ○ ○ ○ ○ ○ ALL Open Master Close ○ ○ ○ Master Slave Master Slave1 Slabe (N-1) Slave N ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 20 Muratec Automation Co., Ltd. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Open ALL Close Open ALL Close Open ALL Close Open ALL Close Open ALL Close Table. 5 CMC-BC DIP Switch Settings (Filter “Enable”, communication speed:19.2kbps) DIP SW1 DIP SW2 DIP SW3 Master/ BC SW4 SW5 Slave No. ON OFF No. ON OFF No. ON OFF ○ ○ ○ ○ ○ ○ ALL Open Master Close ○ ○ ○ Master Slave Master Slave1 Slabe (N-1) Slave N ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 4.2.5. Judgment It passes if all of adjustments are performed and confirmed. 21 Muratec Automation Co., Ltd. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Open ALL Close Open ALL Close Open ALL Close Open ALL Close Open ALL Close 5. CMC-BM Board Setting 5.1. CMC-BM Board Check 5.1.1. Purpose Check for short circuit and earth ground fault before energizing CMC-BC board for the safety. 5.1.2. Required Materials • • Wiring Diagrams, Checklist Multimeter, Phillips-head Screw Driver (+2) 5.1.3. Tips, Precautions and Prohibited Actions ・ Strictly adhere to safety rules for high-place work. ・ Measure the short-circuit and the earth fault after confirming it has no voltage. ・ Work in the energized status is prohibited. 5.1.4. Procedures A) Check for short circuit and earth ground fault on the secondary side of the circuit breaker (see Fig. 14) on the CMC-BM board. Shut off the power for CP1 through 8 of CMC-BC. Since the line is connected to indicator lamp, short circuit check should show 3-4 kΩ. Earth ground fault shall be open. B) Check for short circuit and earth ground fault on the secondary side of the circuit breaker for CP2 through CP5. (Both short circuit and earth ground shall be open.) C) Check for short circuit and earth ground fault on the secondary side of the TB2. (Earth ground shall be open.) D) When all checks are in good conditions, turn on a circuit breaker for CMC-BC, and it energize the BM board. Thereafter, work in the energized status is prohibited. 22 Muratec Automation Co., Ltd. Fig. 14 For example the outward form of the CMC-BM unit 5.1.5. Judgment It passes if all of adjustments are performed and confirmed. 23 Muratec Automation Co., Ltd. 6. Communications Adjustment 6.1. Prerequisites A) Power supply panel start-up adjustments are complete. B) All the CMC boards and all the power supply panels have been started up. C) All the wiring of feeder cables (included dedicated communications lines) is appropriate. Especially perform a check the U/V direction using communications direction checker. D) When OHVC, EPLC and the vehicle are all able to be powered up, turn the power on to all the equipment, then check the communications status between each device. Check that the power lamp is on for all devices. E) No workers are near the tracks. Communications Flow OHVC ←→ CMC-BC ←→ CMC-BM ←→ CMC-TR ←→ Track (Power feeder cables or communications wires) ←→ Vehicle 6.2. Check before Vehicle Start-Up (Track Power Panel is OFF) 6.2.1. Purpose Check for the communication condition when track power panel is OFF. 6.2.2. Required Materials • • Feeder Cable Layout Drawings, Wiring Diagrams, Checklist Phillips-head Screw Driver (+2) 6.2.3. Tips, Precautions and Prohibited Actions ・ Strictly adhere to safety rules for high-place work. ・ Work in the energized state is prohibited. 6.2.4. Procedures A) Turn on all of CMC-BC and CMC-BM. Turn off the entire track power panel. B) Check that LED1~8 of the CMC-BC’s NBV-BC board are not lit. If any of LED1~8 is lit, refer to the troubleshooting guide. 24 Muratec Automation Co., Ltd. LED1-8 CN1 CN2 CN3 CN4 CN5 CN6 CN7 CN8 CN12 CN14 Fig. 15 CMC-BC Board’s NBV-BC 6.3. Check before Vehicle Start-Up (Track Power Panel is ON) 6.3.1. Purpose Check for the communication condition when track power panel is ON and no vehicles on the track. 6.3.2. Required Materials • • Feeder Cable Layout Drawings, Wiring Diagrams, Checklist Phillips-head Screw Driver (+2) 6.3.3. Tips, Precautions and Prohibited Actions ・ Strictly adhere to safety rules for high-place work. ・ Work in the energized state is prohibited. 6.3.4. Procedures A) Turn on the electrical power board, and all of CMC-BC and CMC-BM. B) Check that LED1~8 of the CMC-BC’s NBV-BC board are not lit. C) If any of LED1~8 is lit, refer to the troubleshooting guide. 25 Muratec Automation Co., Ltd. 6.4. Check and Adjustments of each Level of CMC-BM 6.4.1. Purpose Check for the communication condition between one vehicle and the OHVC. 6.4.2. Required Materials • • Feeder Cable Layout Drawings, Wiring Diagrams, Checklist Oscilloscope, Phillips-head Screw Driver (+2) 6.4.3. Tips, Precautions and Prohibited Actions ・ Strictly adhere to safety rules for high-place work. ・ Work in the energized state is prohibited. 6.4.4. Procedures Check and adjust the waveforms of all CMC-BM. Record the noise level, reception waveform level, and squelch. In order to check the difference in reception levels according to location, check these 3 places in order: 1) next to the communications transformer 2) next to the INPUT 3) next to RETURN. Also, to make the waveform check as accurate as possible, use the same vehicle. If the noise level is 0.5V or more, refer to the troubleshooting guide, take countermeasures, then record the capacity of the coaxial cable entrance capacitor after adjustments. A) Check with an installed vehicle Operate a vehicle and a maintenance lifter referring to the vehicle installation/removal instructions. (1) Set the vehicle to AUTO MODE. (2) Send an initial wait command from OHVC. If communications are not established with the vehicle, refer to the troubleshooting guide. B) Receiving waveform check (By communications transformer) (1) Move a vehicle to a location By a communications transformer as shown in the figure below. Using the remote control, switch the vehicle communications side to transformer side only. Check feeder cable layout in provided feeder cable layout drawing. 26 Muratec Automation Co., Ltd. Fig. 16 Positioning OHV (By Communications Transformer) (2) Procedures for receiving waveform check of BV-BM3 are as follows. Connect an oscilloscope to BV-BM3 and monitor receiving waveform. + side: CH201 (CMP_IN) - side: CH100 or CH101 (0V) CH202:TH_L VR202 CH201:CMP_IN VR201 VR2 VR200 LED3 1 2 CH100:0V CH101:0V VR1 Fig. 17 BV-BM3 Check Pin Arrangement (3) Monitor the minimum receiving waveform and the maximum noise level. Range: 1V ~ 2V/DIV, 10mS ~ 20mS/DIV Maximam Noise Level Communication Speed 19.2kbps・・・ 1.0V or below. 28.8kbps・・・ 0.5V or below. 27 Muratec Automation Co., Ltd. Comm. signal (receiving waveform) from OHV -> CMC (OHVC) Comm. signal form CMC (OHVC) -> OHV A. Max. receiving waveform B. Min. receiving waveform Noise level 0V Fig. 18 Receiving Waveform (4) Procedures for BV-BM3 receiving waveform adjustment are as follows. Adjust the waveform level with variable resistance (VR1, VR2, VR200 and VR202) as you monitor the receiving waveform. Adjust variable resistance per one division in order of VR1→VR2→VR200→VR201. Receiving waveform criteria; Minimum level of receiving waveform communication speed :19.2kbps 7V±0.5V 28.8kbps 3V±0.5V Squelch level 1.5V±0.5V If the receiving level does not decrease, rotate all variable resistance fully counter-clockwise. Lines with communication wires If the receiving level does no decrease to the specified value, decrease the number of communication wire turns on the communications transformer. In case the minimum receiving level is 2V or less, increase the number of communication wire turns on the communications transformer. Table. 6 Communication Wire Turns on Communications Transformer Ded. Comm. Line: Length Turn Count to Comm. (One way) Transformer 30m 1 turn 60m 2 turns 90m 3 turns 120m 4 turns 150m 5 turns 28 Muratec Automation Co., Ltd. <3 Turn Definition> Definition> Communication Transformer Dedicated Comm. Line U Side Dedicated Comm. Line V Side Fig. 19 Settings of Dedicated Communications Line (to the Communications Transformer) Turn Count (5) Record the minimum receiving waveform and maximum noise level after adjustment. Save the reception waveform on the oscilloscope. Input the saved graphics to the PC, and save them so that which system has which graphics is understood. C) Squelch check and adjustment (1) Adjust BV-BM3 squelch following the steps below. (2) Connect an oscilloscope to BV-BM3 and monitor squelch. + side: CH202 (TH_L) - side: CH100 or CH101 (0V) Range: 1.0V/DIV, 10mS ~ 20mS/DIV (3) Adjust squelch level with the volume (VR202). Squelch level criteria; Minimum level of receiving waveform communication speed:19.2kbps 7V±0.5V 28.8kbps 3V±0.5V Squelch level (4) Record the adjusted squelch level. 1.5V±0.5V Communications signal (Receiving Waveform): OHV ? CMC (OHVC) Communications signal: CMC (OHVC) ? OHV Min. level of receiving waveform Adjust squelch level to Noise level 1.5V±0.5V 0V Fig. 20 Squelch Adjustments 29 Muratec Automation Co., Ltd. D) Receiving Waveform Check (Next to INPUT) (1) Move the vehicle to coaxial cable’s Next to INPUT. Using the remote control, switch the vehicle’s communications direction to the coaxial cable’s INPUT side. Check the feeder cable arrangement on the Feeder Cable Arrangement Map. Fig. 21 Example of OHV Arrangement (By INPUT) Communications Signal (Reception Waveform): Vehicle → CMC (OHVC) Communications Signal: CMC (OHVC) → Vehicle A Reception Waveform Greatest Value B Reception Waveform Lowest Value Noise Level 0V Fig. 22 Receiving Waveform (2) Monitor the minimum receiving waveform and the maximum noise level. Range: 1V ~ 2V/DIV, 10mS ~ 20mS/DIV Maximam Noise Level Communication Speed 19.2kbps・・・ 1.0V or below. 28.8kbps・・・ 0.5V or below. (3) Record the monitored minimum receiving waveform. Save the waveform to the oscilloscope and download the saved screen to PC. Save the screen with an indication showing which line the screen belongs to. 30 Muratec Automation Co., Ltd. E) Receiving waveform check (By RETURN) (1) Move the vehicle to next to RETURN. Using the remote control, switch the vehicle’s communications direction to the RETURN side. Fig. 23 Example of OHV Arrangement (By RETURN) Communications Signal (Reception Waveform): Vehicle → CMC (OHVC) Communications Signal: CMC (OHVC) → Vehicle A Reception Waveform Greatest Value B Reception Waveform Lowest Value Noise Level 0V Fig. 24 Reception Waveform (2) Monitor the minimum receiving waveform and the maximum noise level. Range: 1V ~ 2V/DIV, 10mS ~ 20mS/DIV Maximam Noise Level Communication Speed 19.2kbps・・・ 1.0V or below. 28.8kbps・・・ 0.5V or below. (3) Record the monitored minimum receiving waveform. Save the waveform to the oscilloscope and download the saved screen to PC. Save the screen with an indication showing which line the screen belongs to. F) Install a cover of the CMC-BM when the adjustment is completed. G) Check and adjust all CMC-BM. H) Load the data saved on an oscilloscope to the maintenance PC, and organized the data. 6.4.5. Judgment It passes if all of adjustments for all CMC-BM are performed or confirmed. 31 Muratec Automation Co., Ltd. 7. Specification Unit name CMC Baud rate 19.2kbps-38.4kbps Communication method Serial Communication, Async HDX Modulation method 2 value FSK(frequency shift keying) Demodulation method Analog PLL demodulation CMC -> Vehicles:285.7kHz and 315.8 kHz (transmits) Communication Frequency Vehicles -> CMC:342.9 kHz and 363.6 kHz(Receive) bit error rate < 1×10-4 Frame error rate < 1×10-2 7.1. CMC-BC (Communication Modem Controller :Base Controller) Unit name CMC-BC Manufacturer MURATEC AUTOMATION CO., LTD. Weight Approx. 10 kgf *Case materials and shape vary with the system Size Power consumption 590mm (W) x 204 mm (L) x 211 mm (H) *Case materials and shape vary with the system 10W Input 1 200V AC 1φ or 100V AC 1φ 50/60Hz Input 2 Vehicle controller―CMC-BC RS232C/RS485 Output 1 CMC-BC―CMC-BM RS485 8 ports max. Output 2 CMC-BC―CMC-BC RS485 1 port Output 3 CMC-BC―CMC-BM 200V AC 1φ or 100V AC 1φ 50/60Hz 7.2. CMC-BM(Communication Modem Controller :Base Modem) Unit name CMC-BM Manufacturer MURATEC AUTOMATION CO., LTD. Weight Approx.7kgf *Case materials and shape vary with the system Size Power consumption 613mm (W) x 266 mm (L) x 71 mm (H) *Case materials and shape vary with the system 20W Input 1 CMC-BC―CMC-BM 200V AC 1φ or 100V AC 1φ Input 2 CMC-BC―CMC-BM RS485 Input 3 CMC-TR―CMC-BM Analog signal 4 ports max. Output 1 CMC-BM―CMC-TR Analog signal 2 ports max. 32 Muratec Automation Co., Ltd. 50/60Hz 7.3. CMC-TR(Communication Modem Controller :TRansformer) Unit name CMC-TR Manufacturer MURATEC AUTOMATION CO., LTD. Weight Approx. 5 kgf *Case materials and shape vary with the system Size Power consumption 430 mm (W) x 226 mm (L) x 91 mm (H) *Case materials and shape vary with the system MAX 1W *When communication signal transmitted through the non-conductive power line Input 1 CMC-BM―CMC-TR Analog signal Output 1 CMC-TR―CMC-BM Analog signal 33 Muratec Automation Co., Ltd. 8. Error process [Note.1] Before servicing CMC-BC,CMC-BM,CMC-TR,always shut off the power supply. [Note.2] If the communication signals are overlaid onto the non-conductive power line, also shut off the power source of the non-conductive power line before starting maintenance on CMC-BM and CMC-TR. Vehicle Controller issues a communication error Is Vehicle Controller sending communication signals? Check the settings for Vehicle Controller. Are the power indicator lights of CMC-BC and CMC-BM illuminated? Is the power supply of 200V AC 1φor 100V AC 1φ50/60Hz connected? Is the input fuse burnt? Replace the fuse. Turn the power supply OFF. Is the input resistance of the DC power almost 0 ohm? Replace the DC power supply. Is the power LED of the print circuit NBV-BC illuminated? Is the power LED of the print circuit BV-BM2 illuminated? Replace the print circuit board Is the connection between CMC-BM and CMC-TR normal? Restore connection. END 34 Muratec Automation Co., Ltd.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 35 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : 469ea1da-528b-11e0-0000-e8233c13c957 Producer : PrimoPDF Modify Date : 2011:03:17 09:44:5509':0' Create Date : 2011:03:17 09:44:5509':0' Creator Tool : PrimoPDF http://www.primopdf.com/ Document ID : 469ea1da-528b-11e0-0000-e8233c13c957 Format : application/pdf Title : Microsoft Word - YSDA-3495Rev3_CMC Operation manual.doc Creator : z07940 Author : z07940EXIF Metadata provided by EXIF.tools