NABCO Entrances ACUMOTION ND-600 Sensor User Manual SR 02602

NABCO Entrances, Inc. ND-600 Sensor SR 02602

Contents

Adjustment manual

SR-02602 Adjustment Manual for Acumotion Prototype  1. Parts list 1)Acumotion: pc   2)3 conductor   Cable: pc (5ft)  3)Antenna:pc     There are two type of the Antenna, such as Wide field which has 3 chips and Narrow Field which has 6 chips.    2. Function of LED Sensor Status Power ON &   No Detection Microwave detects Infrared detects Microwave & Infrared detect LED Status Green Orange Red Off           3. Adjustment 1) Lever for mounting angle of entire sensorLever for mounting angle of entire sensor  This white lever is to adjust the angle of the entire sensor and will be used to adjust the field of the around threshold for Infrared. When you move this white lever to upside, sensing field will be move to close side of the door. 9 positions adjustment is available. (-4 ~ 4 deg.)    2) Angle adjustmeAngle adjustment for Microwave sensornt for Microwave sensor   This part is to adjust the angle of microwave head.  11 positions adjustment is available. (15 ~ 45 deg.)   1 2 3 4 5 6
SR-02602 3) Depth adjustment lever of Infrared sensor Depth adjustment lever of Infrared sensor  This slidable lever is to adjust the depth of infrared field. Lever position [1] : Depth of infrared field      1 ft Lever position [2] : Depth of infrared field     2 ft Lever position [3] : Depth of infrared field     3 ft  When you need the enough depth of microwave field, please adjust this lever ,there is no detection zone between Infrared beams and microwave beams.          4) Dip Switch 1Dip Switch 1 (8 positons)         This switches are for Infrared sensor. Switch Number Function Adustment 1 2   ON ON Mode A ON OFF Mode B OFF ON Mode C 1, 2 Mutual Interference Prevention Mode OFF OFF Mode D 3 4   ON ON High Sensitivity  15 sec ON OFF High Sensitivity    sec  OFF ON Low Sensitivity  30 sec 3, 4 Sensitivity& Presence time adjustment OFF OFF Snow Mode       15 sec    ON ON No Cancellation OFF ON One spot of left outside is cancelled. OFF OFF Two spots of left outside are cancelled. ON OFF Three spots of left outside are cancelled.    ON ON No Cancellation ON OFF One spot of Right outside is cancelled. OFF OFF Two spots of Right outside are cancelled. 5, 6, 7, 8 Adjustment of width OFF ON Three spots of Right outside are cancelled.
SR-02602 5) Dip Switch 2 (4 positions) This switches for the microwave sensor. Switch Number Function Adjustment ON   Uni-directional 1 Bi/Unidirectional OFF Bi-directional    ON ON Standard ON OFF High OFF ON Noise prevention Mode 1 2, 3 Sensitivity of Frequency Noise OFF OFF Noise prevention Mode 2 ON   Effective 4 Infrared ON/OFF OFF Invalid  6) Sensitivity of power for Microwave sensor (Potentiometer)  10 positions adjustment of sensitivity is available by a potentiometer. CW: High Sensitivity, CCW: Low Sensitivity High    4. Wiring  Red:  12VDC Input  Black: 12VDC Ground & Output Common  White: Out put (DC30V/0.1A  max)                 Compliance Statement (Part 15.19)Compliance Statement (Part 15.19)      This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions; 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.  Warning (Part 15.21)Warning (Part 15.21)     Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  RF Exposure (OET Bulletin 65)RF Exposure (OET Bulletin 65)        To comply with FCC RF exposure requirements for mobile transmitting device, this transmitter should only be used or installed at locations where there is at least 20 cm(7.78 inches) separation distance between the antenna and all person.

Navigation menu