NETWORK KOREA AEWC-2000 Web Camera User Manual CCD manual

NETWORK KOREA CO., LTD. Web Camera CCD manual

Users Manual

 1Acknowledgement Thank you very much for purchasing the ATEYE of Network Korea.   • ATEYE Web Camera is developed and produced with only Korean   technologies.  • ATEYE Web Camera is marketed and sold after thorough quality verification.   • ATEYE Web Camera guarantees the rights and interests of consumers with   perfect customer service.   • ATEYE Web Camera will expand the ranges of your selection with various   products.    Customer Service Center • Address: 1st Daeryug Techno Town, 327-24, Kasan-dong, Keumcheon-gu,  Seoul, 153-023, Korea.  • Tel: 02-857-5455 • Fax: 02-857-5480 • URL: WWW.NETKOREA4U.COM Copyright • The software and hardware mentioned in this user manual are the property of Network Korea Co., Ltd. All software and hardware are protected by computer program protection act, copyright act and international copyright conventions including other intellectual property acts and conventions. No part of this manual may be reproduced or transmitted in any form or by any means without permission in writing from Network Korea.   Contents 1. ATEYE Web camera Items & Specifications 1) Items 2) Specifications     2. ATEYE Web Camera Installation   1) Setting ATEYE Web Camera       1.1) Setting the camera ID    1.2) Setting baud rate    1.3) Setting termination  2) Composite cable ( BNC & RCA ) 3) Connecting serial cable   3. ATEYE Web Camera Protocol  4. Troubleshooting       1. ATEYE Web Camera Items & Specifications
 2 1) Items   (1) ATEYE Web Camera   (2)   DC 12V 600mA Adaptor     (3) Serial Cable (RS485 )    (4) Composite cable( BNC & RCA )   (5)   User’s Manual   2) Specifications
 3 ATEYE Web Camera Video Format  NTSC Standard : 525 Lines 30 Frames/sec Scanning System  1/4 Interline   Effective Total Pixel No.  510(H) * 492(V) Signal System  525 Lines Interface Scanning Frequency  Horizontal : 15.734KHz, Vertical : 59.94Hz Synchronization Internal Synchronization Resolution  More than 360 Lines Signal Output  Analog Composite (1.0Vp-p, 75 ohm) S/N ratio  More than 48dB   Minimum Illumination  2Lux Gamma 0.45 Motion range  PAN : 320°    TILT : -30°  ~ +45° Maximun Pan Speed  80°/sec Maximun Tilt Speed  80°/sec Control Interface  RS485 Preset   64 Positions Sensor Out  One     Power  DC 12V, 600mA  2. ATEYE Web Camera Installation 1) Setting ATEYE Web Camera                              [Figure.1] the 8-bit DIP switch factory setting  1.1) Setting the camera ID  ATEYE Web Camera has an inherent camera ID. The total number of camera ID   is 64 from number 0 to number 63. How to set the camera ID is followed. There is a 8-bit DIP switch in the bottom of ATEYE Web Camera Among those switches in Figure.1, the pins of number 1-6 are used for   setting camera ID. Number 1 switch is the lowest level bit(LSB) and number 6 is   the highest level bit(MSB). If the switch is set on, the value is “1”, otherwise, it is “0”. ( binary number )    Example ) In case camera ID is number 5
 4Switch number 1 => On Switch number 2 => Off Switch number 3 => On Switch number 4 => Off Switch number 5 => Off Switch number 6 => Off  That is 101000 => Camera ID is number 5  1.2) Setting the baud rate  ATEYE Web Camera is allowed to use two type of baud rate   ;4800[bps], 9600[bps]. Number 7 switch of 8-bit DIP switch is used for that purpose. If the switch is on, the baud rate is 9600bps, otherwise it is 4800bps.  1.3) Setting the termination   In case that you control more than two ATEYE Web Cameras with one   controller, you must set the termination for preventing the control signal being  lost.  You can use this by handling the last switch of 8-bit DIP switch at figure.1. If you use only one ATEYE Web Camera with one controller, the switch must be  on,  Otherwise, you must set the switch of one ATEYE Web Camera on and that of   the others off.    the 8-bit DIP switch factory setting is followed. Camera ID : 1 Baud rate : 9600 bps Termination : On  2) Composite cable ( BNC & RCA )         A composite cable (BNC & RCA connector) is used in video out & Alarm out.           It is described the protocol of Alarm out in detail in the next pages. 3) Connection the serial cable   ATEYE Web Camera originally uses RS485 communications. The color information of serial cable is followed.                  camera                               controller (DVR etc.) red    Rx(+) white  Rx(-) green  Tx(+) black  Tx(-)  Tx(+) Tx(-) Rx(+) Rx(-)  It is described the protocol in detail in the next pages 3. ATEYE Web Camera Protocol
 5 Data Length  1 Byte (8 bit) Start/Stop Bit  1 Bit Parity Bit  None Baud rate  4800bps, 9600bps(default)    Protocol Format start code  Func_num  Data3  Data2  Data1  Data0  Cam_ID Cam_ID start code : 0x01 Func_num : Function byte Data3 ~ Data0 : Data bytes Cam_ID : Camera ID Check Sum : Check Sum   Sum = FC_NUM + DATA3 + DATA2 + DATA1 + DATA0 + CAM_ID   Low level byte of Sum is used for Check Sum example   0x165 = 0x11 + 0x22 + 0x33 + 0x44 + 0x55 + 0x66   Check_sum = 0x65  -. Pan/Tilt Home(send signal once without signal of stopping ) 0x01  0x8a  0x00 0x00 0x00 0x00 Cam_ID Cam_ID  -. LEFT 0x01 0x88 0x10 0x00 0x00 0x00 Cam_ID Cam_ID  -. RIGHT 0x01 0x88 0x11 0x00 0x00 0x00 Cam_ID Cam_ID  -. UP 0x01 0x88 0x22 0x00 0x00 0x00 Cam_ID Cam_ID  - DOWN 0x01 0x88 0x20 0x00 0x00 0x00 Cam_ID Cam_ID  -. LEFT_UP 0x01 0x88 0x32 0x00 0x00 0x00 Cam_ID Cam_ID  -. RIGHT_UP 0x01 0x88 0x33 0x00 0x00 0x00 Cam_ID Cam_ID  -. LEFT_DOWN 0x01 0x88 0x30 0x00 0x00 0x00 Cam_ID Cam_ID  -. RIGHT_DOWN 0x01 0x88 0x31 0x00 0x00 0x00 Cam_ID Cam_ID -. Pan/Tilt Stop
 60x01 0x80 0x30 0x00 0x00 0x00 Cam_ID Cam_ID  Setting    64 Positions in preset -. assignment(Pos_Num : 0x00 ~ 0x3F) 0x01 0x81 0x01 Pos_Num 0x00 0x00 Cam_ID Cam_ID  -. moving(Pos_Num : 0x00 ~ 0x3F) 0x01 0x81 0x02 Pos_Num 0x00 0x00 Cam_ID Cam_ID  Sensor Output( Alarm out ) -. Open 0x01  0x8  0x44 0x00 0x00 0x00 Cam_ID Cam_ID  -. Close 0x01  0x8  0x40 0x00 0x00 0x00 Cam_ID Cam_ID        4. Troubleshooting 1) Video output is not shown in the monitor.             - Is the camera’s power cable attached correctly?             - Is the BNC cable attached correctly?             - Is the video output format correct? ( NTSC, Analog Composite (1.0V p-p, 75ohm))             - In case all the above is correct, but it does not work right, please contact us.  2) Pan/tilt motion of camera does not be controlled.             - Is the camera’s power LED of the camera on?             - Is the switch of 8-bit DIP switch set correctly?             - Is the protocol of pan/tilt motion set correctly? (confirm that in chapter 3)             - Is the serial cable connected correctly?             - In case all the above is correct, but it does not work right, please contact us.
 7FCC NOTICE   NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment of  and on, the user is encouraged to try to correct the interference by one or more of the following measures:  - Reorient or relocate the receiving antenna.  - Increase the separation between the equipment and receiver.  - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  - Consult the dealer or an experienced radio/TV technician for help.   NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.  Such modifications could void the user’s authority to operate the equipment.