Navico BR24 FMCW WITH LINEAR FREQUENCY SWEEP User Manual FMCW Install cover indd
Navico Auckland Limited FMCW WITH LINEAR FREQUENCY SWEEP FMCW Install cover indd
Navico >
USERS MANUAL
in ar Installation Manual Navico Broadband Radar BR-24 Pr el im English Preliminary www.lowrance.com www.northstarnav.com. www.simrad-yachting.com Brands by Navico - Leader in Marine Electronics in ar im el Pr Navico Radar Broadband Installation manual English, Doc.no. Preliniary 1 Preface FCC Statement Note: This equipment has been tested and complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a normal installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. in ar If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an output on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced technician for help. • A shielded cable must be used when connecting a peripheral to the serial ports. Industry Canada Operation is subject to the following two conditions: (1) this device may not cause interference, and im (2) this device must accept any interference, including interference that may cause undesired operation of the device. Refer also to the system specifications section. el CE Compliance Pr Navico New Zealand, declares that this Radar Processor is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Preface | 1 Disclaimer As Navico is continuously improving this product, we retain the right to make changes to the product at any time which may not be reflected in this version of the manual. Please contact your nearest distributor if you require any further assistance. It is the owner’s sole responsibility to install and use the instrument and transducers in a manner that will not cause accidents, personal injury or property damage. The user of this product is solely responsible for observing safe boating practices. NAVICO HOLDING AS. AND ITS SUBSIDIARIES, BRANCHES AND AFFILIATES DISCLAIM ALL LIABILITY FOR ANY USE OF THIS PRODUCT IN A WAY THAT MAY CAUSE ACCIDENTS, DAMAGE OR THAT MAY VIOLATE THE LAW. Governing Language: This statement, any instruction manuals, user guides and other information relating to the product (Documentation) may be translated to, or has been translated from, another language (Translation). In the event of any conflict between any Translation of the Documentation, the English language version of the Documentation will be the official version of the Documentation. in ar This manual represents the product as at the time of printing. Navico Holding AS. and its subsidiaries, branches and affiliates reserve the right to make changes to specifications without notice. Copyright © 2008 Navico Holding AS. Warranty The Navico warranty card is supplied as a separate document. It is shipped with the product registration card. im In case of any queries, refer to Navico.com. Feedback from you Pr el Your feedback is important and helps Navico ensure that this manual is a valuable resource for all marine technicians. E-mail your comments or suggestions about this manual to the following address: tech.writing@navico.com 2 | Preface Contents 1 Preface ........................................................................................................ 1 FCC Statement ............................................................................................. 1 Industry Canada ........................................................................................... 1 CE Compliance ............................................................................................. 1 Disclaimer ................................................................................................... 2 Warranty ..................................................................................................... 2 Feedback from you ....................................................................................... 2 in ar 2 Introduction to the Navico Broadband radar system ................................... 5 What is Broadband radar? .............................................................................. 5 Radar system overview.................................................................................. 7 Warnings ..................................................................................................... 7 3 Install the radar........................................................................................... 8 Check the parts ............................................................................................ 8 Choose the scanner location ........................................................................... 9 Mounting the scanner .................................................................................. 10 im Mounting the radar interface box .................................................................. 11 4 Wiring the radar system ............................................................................ 12 Connect interconection cable to the scanner ................................................... 12 Connect the interconnection cable to radar interface box .................................. 12 el Connect power ........................................................................................... 14 Connect the Broadband radar to your display.................................................. 16 Lowrance HDS (U.S only)......................................................................................16 Pr Lowrance HDS (Non U.S market) ...........................................................................16 GB40 .................................................................................................................16 8000i .................................................................................................................16 NX40 and NX 45 ..................................................................................................17 M84 and M121 ....................................................................................................17 Connecting a heading sensor ........................................................................ 18 GB40 .................................................................................................................18 NX 40, NX45 .......................................................................................................19 8000i NMEA 0183 ................................................................................................19 M-84 and M-121 ..................................................................................................20 5 Configure displays to use radar ................................................................. 21 Lowrance HDS radar setup ........................................................................... 21 Simrad GB40 / Northstar 8000i radar setup .................................................... 21 Simrad NX40/45 or Northstar M84/M121 radar setup....................................... 22 Preface | 3 6 Drawings ................................................................................................... 23 Radar interface box..................................................................................... 23 Scanner dimensions .................................................................................... 24 7 Specifications ............................................................................................ 25 8 Navico Broadband radar part numbers ...................................................... 26 Pr el im in ar 9 Maintenance .............................................................................................. 27 4 | Preface 2 Introduction to the Navico Broadband radar system What is Broadband radar? The Navico Broad band radar uses FMCW (Frequency Modulated Continuous Wave) radar technology What is FMCW? FMCW radar is different: in ar The current normal leisure radar generates microwave pulses with a thermionic device called a magnetron. This ancient technology sends out bursts of high power microwave energy periodically, and the radar detector listens to the echoes coming back from each pulse. As the radar rotates these echoes are built into a 360 degree image. Firstly it is solid state – i.e. the transmitter is a semiconductor device, not based on thermoinic valve technology. Secondly it transmits continuously, not in pulses and thirdly it measures the time of the echo not by listening to a received pulse but by varying the frequency of the transmitted signal and detecting the shift in frequency in the received echo. Hence FMCW – Frequency Modulated Continuous Wave. The building up of the image over 360 degrees and the processing of the radar data is the same as for a magnetron radar. Pr el im How does FMCW radar work? FMCW = Frequency Modulated Continuous Wave The scanner transmits a ‘rising tone’ (Tx wave) with linear increasing frequency. The wave propagates out from the transmitter retaining the frequency it had when it was transmitted. If it reflects off an object, it will return to the receiver, still at the frequency it had when originally transmitted. Meanwhile the transmitter continues to output an increasing frequency Introduction to the Navico Broadband radar system | 5 The difference in the currently transmitted and currently received frequencies, coupled with the known rate of frequency increase, allows a time of flight to be calculated, from which distance is calculated Benefits of FMCW radar Safer • low energy emissions, similar to a cell phone • more flexibility in placement on boat • can run in anchorages and marinas Short range performance • Conventional radars can not see anything closer than 30 meters • FMCW can see within a few meters of the boat • See the objects that pose the greatest threat to your boat in ar Low power • expands market to small boats and yachts • easier install, lighter cabling • great for yachts on ocean passage Instant power-up • Conventional radars take 2-3 minutes to heat up the filament: Safety – 2 minutes is a long time if you are concerned about collision Convenience – switch it on and use it Pr el im • 6 | Introduction to the Navico Broadband radar system Radar system overview The Navico Broadband radar is a state of the art navigation aid providing outstanding radar performance with out the limitations of conventional pulse radars such as dangerous high power microwaves, Standby warm up time, high power consumption and large open arrays which is what would be required to obtain the same image quality at shorter ranges . The Navico Broadband radar as an effective range from 1/16 to 24 nm. and has an operating power consumption of 17 W. The system consists of radar scanner, an interface box and a interconnection cable. The scanner is housed in a dome on is of similar size to most 2 kW radars on the market. in ar The interface box is used to connect displays and heading information. There are two models (RI-10 and RI-11) depending on the display system used the main difference being one has a SimNet connector for heading input (RI-10). The other interface box (RI-11) has a connector to interface to RS422 displays and NMEA 0183 heading sensors. both interface boxes have a Network connector to interface to Ethernet displays. Note Lowrance HDS units sold in the USA do not require an interface box and the scanner connects directly to the display or ethernet switch Model Lowrance HDS USA Lowrance Data connection protocol Chart overlay MARPA N/A Ethernet Yes* Yes** HDS R.O.W RI-11 Ethernet Yes* Yes** Simrad GB40 RI-10 Ethernet Yes* Yes** Northstar 8000i RI-11 Ethernet Yes* Yes** Northstar 8000i + N2k RI-10 Ethernet Yes* YES** M series RI-11 RS422 Yes* No NX 40/45 RI-11 RS422 Yes* No Northstar Simrad Radar interface box used im Brand Radar connection kit el *For best chart overlay performance use a heading sensor. Course over ground can be used but only when moving Pr ** For MARPA it is essential to use a heading sensor with an out put speed of 10 hZ or faster Warnings Introduction to the Navico Broadband radar system | 7 3 Install the radar Installation includes: • mechanical mounting • electrical wiring • configuring the display or network system to work with the radar • adjusting the radar for proper performance Don't take any shortcuts, and follow these instructions carefully! This section explains how to: • choose the correct location for the scanner install the scanner on a power boat or a yacht • choose the correct location for the radar processor • install the radar processor Check the parts in ar • Pr el im NEED A BREAK DOWN OF KITS AND UNDER LYING PARTS 8 | Install the radar Choose the scanner location The radar's ability to detect targets depends greatly on the position of its scanner. The ideal location for the scanner is high above the vessel's keel line where there are no obstacles. A higher installation position increases the radar ranging distance, but it also increases the minimum range around the vessel where targets cannot be detected. When you're deciding on the location, consider the following: • the length of the interconnection cable supplied with your radar is usually sufficient. If you think you'll need a longer cable, consult your dealer before installation, because a longer cable may reduce the performance of the radar. if the roof of the wheelhouse is the highest existing location, consider installing a radar mast or a pedestal on which you can mount the scanner. You may also need to construct a working platform for your own safety during installation and servicing work. • if you mount the scanner on a pedestal or base, ensure that rain and sea spray can drain away from it rapidly. • if you locate the scanner on the mast, position it on the forward side so that there is a clear view to the front of the vessel. • the scanner is usually installed parallel to the line of the keel. • ensure that the location site provides the scanner with a clear view of the front of the vessel. in ar • DON'T DO THIS! • DON'T install the scanner too high up, where its weight will alter the stability of the vessel and cause degradation of the radar picture over short ranges. DON'T install the scanner close to lamps or exhaust outlets. The heat emissions may damage the dome. Soot and smoke will degrade the performance of the radar. • DON'T install the scanner close to the antennas of other equipment such as direction finders, VHF antennas, GPS equipment and so on, because it may cause interference. • DON'T install the scanner where a large obstruction (such as an exhaust stack) is at the same level as the beam, because the obstruction is likely to generate false echoes and/or shadow zones. • DON'T install the scanner where it will be subjected to strong vibrations (such as a derrick post) because these vibrations will degrade the performance of the radar. Pr el im • Install the radar | 9 Mounting the scanner • Use the supplied mounting template and tape it securely to the chosen location site. • Before drilling, check that: you have oriented the mounting template correctly so that the front of the scanner unit will face the front of the vessel the location site is not more than 15 mm (0.6") thick. If the location site is thicker use longer bolts Note: The bolts supplied are M8 x 30 mm x 4. If you need to use longer bolts make sure they are 304 stainless steel and allow for 15 mm (0.6") of thread contact the location site allows the drain hole to empty. • Drill the four holes where shown. • Remove the mounting template, • Connect the scanner interconnection cable (see "Connect the Broadband radar to your display" page 16) • Position the scanner carefully over the bolt holes so that they are aligned • Place a spring washer then a plain washer onto each bolt, as shown. • Screw each bolt into each drill hole from the under side of the location site, and tighten securely Pr el im in ar • 10 | Install the radar Mounting the radar interface box Install the radar interface box in a dry location away from spray, rain, drips and condensation. • The radar processor must be located where it can be easily connected to the ship's ground, the scanner interconnection cable, a power source and the display or display network. • Allow enough room for cables to form a drip loop. • Preferably mount the radar interface box on a vertical surface with cables exiting downwards. • Secure to the surface using the four mounting points Pr el im in ar • Install the radar | 11 4 Wiring the radar system Connect interconection cable to the scanner The scanner interconnection cable connects the scanner to the RI-10 or RI-11 interface box (or Lowrance HDS U.S only). The cable connects to the scanner using a 14 pin connector. Insert cable connector on to the male 14 pin plug on the scanner. take care to align the connector correctly to avoid bending the pins. Secure the locking collar by rotating clockwise Feed and secure the cable into the cable retention channel Interconnection cable pin out in ar Pinout Conn Cable connector RJ45 Black Tinned wire Red Tinned wire Yellow Tinned wire Drain Tinned wire N/A N/A Blue RJ45 Pin 4 White / Blue RJ45 Pin 5 white / Brown RJ45 Pin 7 Brown RJ45 Pin 8 10 White / Green RJ45 Pin 3 11 N/A N/A 12 White / Orange RJ45 Pin 1 13 Green RJ45 Pin 6 14 Orange RJ45 Pin 2 el im Scanner connector Wire color Connect the interconnection cable to radar interface box Remove the 4 phillips screws that secure the cable gland housing and disassemble • slide the lock nut, gland washer, and glad housing on to the scanner cable • connect power wires to the terminal strip • connect the RJ45 data connector • secure the gland housing to the interface box using the 4 screws • Insert the gland washer into the gland housing Pr • 12 | Wiring the radar system screw the lock nut on to the gland housing Key in ar • Description Lock nut Gland washer Screws x 4 M3x12mm phillips pan head Cable gland housing Power wires (see "Connect power" page 14) Radar data connector RJ45 el im Radar interface box SR000041-G AA010204 (Serial) AA010189 (Network) Pr Part Number Wiring the radar system | 13 Shortening the cable It is not recommended to shorten the cable but if it is essential use the pin-out below to reterminate the RJ45 connector RJ45 Connector Pin White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown in ar 15 mm Heat shrink (10 mm dia) im RJ45 Connector Colour Connect power Before connecting power to the system: make sure the scanner has been installed and is secured • make sure the scanner cable is connected to the scanner • if using the Radar Interface Box make sure all connections have been made to the display el • Pr The radar system can operate on voltages of 9-32 V DC. The system requires a (+ V DC) to be applied to the yellow remote power on wire in order to operate. This can be achieved by one of three ways. • Common the red and yellow wires together. Radar will power on when power is applied • Install a switch that will provide power to the yellow wire. Radar will turn on when switch is activated • Connect to the yellow wire to a the external wake up of a suitable display. Radar will turn on when display is turned on For systems using a radar interface box • Connect the red wire to power positive 9-32 V DC. Use a 5 amp fuse or breaker • Connect the yellow wire to power source that will turn on the system (see above) • Connect black to power negative It is recommended where possible to connect the radar interface box to ships ground 14 | Wiring the radar system in ar For systems that do not require a Radar Interface Box, connect power directly to the scanner cable. Pr el im Note: Connect shield to ships ground if applicable or connect to battery negative Wiring the radar system | 15 Connect the Broadband radar to your display Lowrance HDS (U.S only) Broadband scanner Adapter cable HDS Display ENET Port in ar 000-0127-56 0.6 m (2 ft) Optional 5 port switch Lowrance broadband in the US market does not require a Radar interface box. the scanner connects directly the display or ethernet switch via the adaptor cable im Lowrance HDS (Non U.S market) Ethernet cable Lowrance 5 port ethernet switch HDS Display ENET port el RI-11 NETWORK port Pr GB40 RI-10 NETWORK port Adaptor cable Ethernet cable 8 port Ethernet linker or cross-over cable NETWORK port Connects to GB40 system via ethernet. Connect a GB40 ethernet cable in between 8 port ethernet linker (or crossover cable) and supplied adaptor cable. Use only GB40 8000i ethernet cables 8000i 12" Display processor or Black box processor 16 | Wiring the radar system RI-11 NETWORK port Adaptor cable Ethernet cable 000-0127-56 AA000056 8 port Ethernet linker (or cross-over cable) NETWORK port AA010009 (AA010084 in ar Connects to 8000i system via ethernet. Connect 8000i ethernet cable in between 8 port linker (or crossover cable) and supplied adaptor cable. NX40 and NX 45 M84 and M121 Data cable NX or M series AA010114 3m (9.8 ft) RADAR port im RI-11 Pr el COMMS port Wiring the radar system | 17 SimNet heading sensor in ar Connecting a heading sensor SimNet to NMEA converter HDS NMEA 2K port FC40 or RC42 Pr el im GB40 SimNet heading sensor RI-10 GB40 Navcomputer FC40 or RC42 SimNet port SimNet port For MARPA functionality on GB40 heading information at 10 Hz needs to be sent to both the RI-11 and the GB40 NavComputer. Connect a SimNet drop cable from the Simnet backbone to the RI-11 and connect to the COMS port (SimNet connector) 18 | Wiring the radar system SimNet heading sensor FC40 or RC42 in ar NX 40, NX45 AT40 or AT45 SimNet to NMEA 0183 converter NX 40 or NX45 GPS port For accurate radar chart overlay a heading sensor on the SimNet backbone passes thought the AT40 or AT45 which connects to the GPS port on the NX display 8000i NMEA 0183 el im 12" Display processor, Black box processor, Simrad GB40 not using a SimNet heading sensor Junction Box RI-11 8000i navcomputer COMMS port Utility port Pr NMEA0183 Heading Sensor For MARPA functionality, heading information at 10 Hz needs to be sent to both the RI-11 and the 8000i master navcomputer. Use the 12 pin cable AA010070 cable from both units to a junction box to share the same heading source. Wiring the radar system | 19 M-84 and M-121 Juncti on box RI-11 Connection kit M-84 or M121 Display COMMS port AA010112 Radar port in ar NMEA0183 heading sensor Pr el im For accurate radar overlay use an NMEA0183 heading sensor. Use supplied connection kit 20 | Wiring the radar system 5 Configure displays to use radar Setup and configuration of the Broadband radar has been simplified compared to traditional pulse radars. There is no warm up time or burn in required. there is no "main bang" setup. The only adjustment needed is to • Set the scanner height: This is to help the radar calculate for sea clutter • Adjust the heading marker. This is to align with the heading marker on the screen with the center line of the vessel, this will compensate for any slight misalignment of the scanner during installation. Any inaccuracy will me evident when using MARPA or chart overlay. in ar Lowrance HDS radar setup To commission the radar using Lowrance HDS. Set the bearing alignment and antenna height. Enter radar installation by pressing Menu > Settings > Radar > Installation. To set the antenna height • Use the up / down arrows to select antenna height. Use the Left / Right arrows to select the antenna height. The value will represent the antenna height in the units that have selected such as feet ot meters. To start the radar • Press pages > Radar > Radar State. Use Cursor to edit the radar state. Select transmit to activate the radar im To adjust the bearing alignment Use the up / down arrows to select bearing alignment. Use the Left / Right arrows to adust bring the heading line on the screen to represent the actual heading of the boat. point the boat to the end of a head land or peninsular. adjust the bearing alignment so th heading line touches the end of the same head land or peninsular el Simrad GB40 / Northstar 8000i radar setup To Set antenna height Select Pages (Display 8000i) > Setup > Radar. • Press edit and key in the height of the scanner in feet or meters depending on system units setting • Select Return Pr • To Transmit • From the radar page select Radar Mode • Select transmit To change the radar bearing alignment: • Select Pages (Display 8000i). If you: don't have a page that shows the Radar screen in one pane and the Chart screen in the other pane, edit or create a page that shows these two screens. do have a page that shows the Radar screen in one pane and the Chart screen in the other, select it. • Check that the Chart screen has the Radar Overlay turned On. • Select the Radar pane so that it becomes the active pane. If you can't see the Adjust Radar button, select Return. Configure displays to use radar | 21 • Select Adjust Radar, then select Installation. • The Bearing Alignment button shows the current setting. Select it to change the setting. Use the Up and Down buttons to move the radar image one degree at a time, until the radar overlay is aligned with the chart. • Select OK. • Select Return. Simrad NX40/45 or Northstar M84/M121 radar setup When the radar is enabled, it will turn on, warm up, and enter standby mode. To enable the radar functionality: Press Setup (NX) or menu twice to display the Setup menu, then select system • Set Radar to Zero bearing in ar • Adjust this on a chart window with the radar overlay on. • Press Menu twice > Radar > Installation • Select Zero bearing then use the arrow keys to enter the new bearing angle. Antenna height Press Menu twice > Radar > Installation • Select Antenna height then enter the height of the antenna above sea level. Pr el im • 22 | Configure displays to use radar 6 Drawings Pr el im in ar Radar interface box Drawings | 23 Pr el im in ar Scanner dimensions Key 24 | Drawings Description Cable entry area Cable retention channel Bolt holes x 4 M8 x 30 mm Breather 7 Specifications Characteristic Technical Data General Compliance FCC/IC/R&TTE/AUS Type Certification pending FCC ID: RAYBR24 IC ID: 4697A-BR24 Environmental IEC60945 4th edition 2002-2008 Operating Temperature: -25° to +55°C Relative humidity: +35° C, 95% RH Relative wind velocity Power consumption in ar Waterproof: IPX6 36.0 m/sec (Max:70 Knots) Operating: 17 W (Typ.) @ 13.8 Vdc Standby: 1.6 W (Typ.) @ 13.8 Vdc - only 110 ma DC input (at end of radar cable) 9 V to 31.2 V DC (12/24 Volt systems). Reverse polarity protection Transmitter Source (Pre-heating time ) No magnetron - Instant ON Outside dimensions Height 280 mm x Diameter 488 mm Weight (no cable) 7.4 kg Radar and Antenna Parameters Radar Ranges 24 rpm +/- 10% im Rotation 1/16 to 24 nm with 15 range settings (nm/sm/km) Transmitter frequency X-band - 9.3 to 9.4 Ghz Transmitter source (warmup time) No Magnetron - all solid state. Instant ON Plane of polarization Horizontal polarization Transmitter peak power output 100 mW nominal 200 Hz Sweep Time 1 ms el Sweep Repetition Frequency 65 MHz max Horizontal Beam width (Tx and Rx antenna) 5.2° +/- 10% (-3dB width) Vertical Beam width (Tx and Rx antenna) 30°+/-20% (-3dB width) Side lobe level (Tx and Rx antenna) Below -18 dB (within ±10°);Below -24dB (outside ±10°) Noise figure Less than 6dB Pr Sweep Bandwidth Coms/Cabling/Mounting Com Protocol High Speed Ethernet Heading NMEA2000 / Simnet with interface box Inter Connecting cable length 10 m standard with RJ45 thin custom connector - Display model dependent Maximum Inter Connecting cable length 30 m Bolts (4) 30 x M8 - 304 stainless steel Footprint W233 mm (port / starboard) x L141.5mm Compatible Displays Lowrance HDS - 5”, 7”, 8”. 10" Simrad GB40 - 10”, 12”, 15” Simrad NX40/45 - 8”, 12” Northstar 8000i - 12”, 15” Northstar M84/M121 - 8”, 12” Specifications | 25 8 Navico Broadband radar part numbers Broadband radar scanner part numbers Model Part Number Description Length BR24 AA010186 Broad band radar scanner RI-10 AA010189 Broadband radar SimNet interface box RI-11 AA010204 Broadband radar serial interface box AA010211 Broadband scanner interconnection cable 10 m (33 ft) AA010212 Broadband scanner interconnection cable 20 m (65.6 ft) AA010213 Broadband scanner interconnection cable 30 m (98.5 ft) 000-00127-56 Adapter cable: yellow ethernet male to RJ45 female 2 m (6.5 ft) AA010079 Navico Ethernet cable for GB40 and 8000i 0.5 m (1.6 ft) AA010080 Navico Ethernet cable for GB40 and 8000i 2 m (6.5 ft) AA010081 Navico Ethernet cable for GB40 and 8000i 5 m (16.4 ft) AA010082 Navico Ethernet cable for GB40 and 8000i 10 m (33 ft) AA010083 Navico Ethernet cable joiner F/F for GB40 and 8000i 0.3 m (1 ft) 000-00127-28 Navico Ethernet cable E-Yellow-E-Yellow for Lowrance 0.6 m (2 ft) Scanner Interface boxes in ar Scanner cables el im Ethernet cables Pr AA010070 AA010114 26 | Navico Broadband radar part numbers Data cables Utility cable, 12 pin F / tinned wires for GB40/8000i 2 m (6.5 ft) HD serial comms cable for NX40/45 and M84/121 3 m (9.8 ft) 9 Maintenance Clean the radome using soapy water and a soft cloth. avoid using abrasive cleaning products. Do not use solvents such as gasoline, acetone, M.E.K etc. as this will damage the dome surface Pr el im in ar Upgrading Firmware Maintenance | 27 Navico Broadband Radar BR-24 Installation manual English, Doc.no. Preliniary
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2008:11:05 17:02:50+13:00 Create Date : 2008:11:05 17:02:50+13:00 Metadata Date : 2008:11:05 17:02:50+13:00 Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Title : FMCW_Install_cover.indd Creator : dave.fereday Document ID : uuid:f7fd7397-9635-4cd5-95e1-68f060241cd2 Instance ID : uuid:5b79a425-e901-4431-a5de-18fa4ec6c2d4 Producer : Acrobat Distiller 8.1.0 (Windows) Has XFA : No Page Count : 30 Author : dave.feredayEXIF Metadata provided by EXIF.tools