Nedap N V T325RRFMDID ASSY T325R RF+MD+RFID User Manual Manual

N. V. Nederlandsche Apparatenfabriek NEDAP ASSY T325R RF+MD+RFID Manual

Contents

Manual

Download: Nedap N V T325RRFMDID ASSY T325R RF+MD+RFID User Manual Manual
Mirror Download [FCC.gov]Nedap N V T325RRFMDID ASSY T325R RF+MD+RFID User Manual Manual
Document ID4038812
Application IDNqvDcW/fQxKbAd9PML0mAg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize184.73kB (2309154 bits)
Date Submitted2018-10-11 00:00:00
Date Available2018-10-17 00:00:00
Creation Date2018-03-28 13:31:51
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-10-16 09:03:20
Document TitleManual
Document CreatorAdobe InDesign CC 13.1 (Windows)

Lumen iL33
ASSY T325R RF IR PR
4x | insullation ring
1x | ASSY T325R RF
2x | filter
2x | connector RJ45
Warning
This equipment should be installed, operated, serviced, and repaired by qualified personnel only. The installation and interconnection of this equipment to facility wiring and other
equipment must be done by a competent, qualified craftsperson who is familiar with applicable standards and codes governing the installation. Installation methods, practices, or
procedures that are unauthorised or done improperly are dangerous and could result in serious personal injury or damage to property and equipment.
20mm 0.79in
325mm 1'0.80"
dimensions
277,5mm 10.93in
231.7mm 9.12in
1534.3mm 5'0.41"
1378.3mm 4'6.26" (Customer counter)
60mm 2.36in
Mounting holes
Use M10-studs
322mm 1'0.68"
97.7mm 3.85in
328.6mm 1'0.94"
conduit or slit
(topview)
Quick reference : ASSY T325R RF IR PR
N.V. Nederlandsche Apparatenfabriek “Nedap”
dsgn
: CvdB
Parallelweg 2, NL-7141 DC Groenlo (The Netherlands)
date
: 28 March 2018 1:31 PM
Mail: support-retail@nedap.com
item
: 9224386
Copyright © by N.V. Nederlandsche Apparatenfabriek NEDAP. No part of this drawing may be reproduced or distributed
document : T9224386-45.01
in any form or by any means, or stored in a data base or retrieval system without the prior written permission of NEDAP.
revision
: A.01
drill the hole
Øø 13
mm/(Ø
0.5in)
13mm
ø 0.5”
Drill the hole
Clean the hole
Insert Hilti-hit
Place the nut
always use a nylon insulation ring
22
Nut M10			
(not included in installation set)
Retainer ring M10		
(not included in installation set)
Nylon insulation ring M10
(included in installation set)
remove covers
9090mm
mm (3.5in)
/ 3.5”
Screw M3x10
installation orientation
Power Inserter (P.I.)
always on the right side.
The arrow indicates the
direction to the store exit.
place near to a wallsocket (RF)
distance to the wall (RF)
>>20
(7.9in)
20cm
cm (7.9
in.)
distance to a normal door or sliding door (RF)
> 40
cm (15.8in)
> 40 cm (15.8 in.)
distance to roller shutter (RF)
> 70
(27.6in)
> 70cm
cm (27.6
in.)
cabling
Ethernet cable
Renos side
filters
Filter
Renos network IN
Renos network OUT
P.I. > network OUT
power system
Plug the Power Inserter into the socket.
230V
115V
INPORTANT:
Network should be connected in the “network setup”-step of the installation wizard.
Do not connect a network to !Sense before power up!
NOTE:
Start up takes
approximately 3 minutes.
connecting a laptop to the Renos unit
Renos - Service port
Attach your laptop to one of the Renos units with a mini USB-USB cable.
Open the browser on your laptop and go to:
http://192.168.133.1
Configure the system using the installation wizard.
place keyswitch
(optional)
Remove cover
Push to remove small metal part
Place keyswitch (can be placed on both sides of the antenna)
place covers
Screw M3x10
label information
Pull to see the label information (Two labels at the front side and one at the back side)
network setup
When on the “network setup” -step of the installation wizard,
determine the position of the network and decide how to connect to the !Sense network.
Network to Power Inserter IN
Network to last Renos OUT
Network to USB-Network adapter (in any gate)
Renos
50Ω			
Connect to the 50Ω PCB from the antenna.
Lights / IR			
Connect to the lights and customer counting.
Add-on			
Provide power and synchronisation to add-ons, like the RFID reader.
Network IN			
Connected to the Network OUT of a previous Renos unit or a Power Inserter.
USB			
Connect accessories to Renos, like the RFID reader or USB network adapter.
Network OUT		
Connected to the Network IN of a previous Renos unit or a Power Inserter.
Mini USB service port		
Connect your laptop to configure the Renos system.
RS485 connector		
Connect to the smart deactivator(s).
Buzzer connector		
Connect to the buzzer.
Can also be left unconnected or connected to the customer network.
Caution:
Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions.
status LEDs Renos
Green
Blue
Red
Yellow
Green
Green
On		
There is a Renos unit connected to the OUT port of this unit
Off		
There is no Renos unit connected to the OUT port of this unit
Blinking		
There is no device connected to the OUT port of this unit
On		
There is a Power Inserter connected to the OUT port of this unit
On		
There is an issue with the power supply at the OUT port of this unit (too little current drawn)
Blinking		
There is an issue with the power supply at the OUT port of this unit (too much current drawn)
Off		
There is no issue with the power supply at the OUT port of this unit
Blinking		
The operating system on the Renos unit is running
Off		
The operating system on the Renos unit is not running
Blinking		
The storage flash on the Renos unit is accessed
Off		
The storage flash on the Renos unit is not accessed
On		
The firmware on the Renos unit is running
Off		
The firmware on the Renos unit is not (yet) running
Disclaimer
Nedap intends to make this manual accurate and complete. However, Nedap does not warrant that the information contained herein covers all details, conditions
or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. Nedap disclaims any liability for damage
to property or personal injury resulting, in whole or in part, from improper installation, modification, use or misuse of its products. The information contained in
this document is subject to change without notice.
FCC and IC Compliance statement
This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Cet appareil se conforme aux normes CNR 210 exemptés de license du Industry Canada. L’opération est soumis aux deux conditions suivantes:
(1) cet appareil ne doit causer aucune interférence, et
(2) cet appareil doit accepter n’importe quelle interférence, y inclus interférence qui peut causer une
opération non pas voulu de cet appareil. Les changements ou modifications n’ayant pas été expressément approuvés par la partie responsable de la
conformité peuvent faire perdre à l’utilisateur l’autorisation de faire fonctionner le matériel.
FCC and IC Radiation Exposure Statement
This equipment complies with FCC and Canadian radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 5cm between the radiator and a human body for normal operation. Personel standing permanently next to the antenna
frame must keep a distance of at least 30cm. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Cet équipement est conforme a CNR-102 limites énoncées pour un environne- ment non contrôlé. Cet équipement doit être installé et utilisé avec une distance
minimale de 5 cm entre le radiateur et un corps humain pour un fonctionnement normal. Les personnes se tenant en permanence à côté du cadre de l’antenne
doivent respecter une distance minimale de 30 cm.This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de Classe B est conforme à la norme Canadienne ICES-003.
FCC Information to the user
Note: This equipment has been tested and found to comply with the limits for a class B digital devices, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequent energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio or television reception, which
can be determine by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an
outlet on a circuit different from that to which the receiver.
NOTE: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To
ensure compliance with FCC regulations, use only the shielded interface cables provided with the product, or additional specified components or accessories
that can be used with the installation of the product.
Declaration of Conformity
Hereby, De N.V. Nederlandsche Apparatenfabriek “Nedap” declares that the radio equipment type ASSY T325R RF is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: https://portal.nedapretail.com/
User manual
The complete instruction manual can be found at https://portal.nedapretail.com/
8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2018:03:28 13:31:51+02:00
Creator                         : Adobe InDesign CC 13.1 (Windows)
Modify Date                     : 2018:10:16 09:03:20+02:00
Has XFA                         : No
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 91.163280, 2018/06/22-11:31:03
Metadata Date                   : 2018:10:16 09:03:20+02:00
Creator Tool                    : Adobe InDesign CC 13.1 (Windows)
Instance ID                     : uuid:b14964d1-d55c-4448-a7bb-ae0ebdbbe476
Original Document ID            : xmp.did:FD7F1174072068119457DD866944A140
Document ID                     : xmp.id:dd18de64-d7ca-9242-b8f1-78049cae488c
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:513f1e91-6e3a-5c4b-877b-8be43baff8b1
Derived From Document ID        : xmp.did:6A305B24E303E211A740EE653DA3658D
Derived From Original Document ID: xmp.did:FD7F1174072068119457DD866944A140
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Windows)
History Changed                 : /
History When                    : 2018:03:28 13:31:51+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CGDT325RRFMDID

Navigation menu