Nedap N V TDC Deactivator User Manual TDC Duc Buzzer Buzduc V1 60
N. V. Nederlandsche Apparatenfabriek NEDAP Deactivator TDC Duc Buzzer Buzduc V1 60
Contents
- 1. user manual
- 2. User Manual 1
- 3. User Manual 2
User Manual 1
Installation Sheet - TDC DUC - TDC BUZDUC - TDC BUZZER - TWO- / FOUR WAY SPLITTER Date: 08 September 2004 Version 1.60 This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. _________________________________________________________________________________________________________ © Nedap Retail Support P.O. Box 102 NL-7140 AC Groenlo the Netherlands © 2004 Nedap Retail Support Netherlands Parallelweg 2d, 7141 DC Groenlo The software / hardware described in this book / file is furnished under a license agreement and may be used only in accordance with the terms of the agreement. Documentation version 1.60 Copyright Notice All Rights Reserved. Any technical documentation that is made available by Nedap Retail Support is the copyrighted work of Nedap Retail Support and is owned by Nedap Retail Support. NO WARRANTY. The technical documentation is being delivered to you and Nedap Retail Support makes no warranty as to its accuracy or use. Any use of the technical documentation or the information contained therein is at the risk of the user. Documentation may include technical or other inaccuracies or typographical errors. Nedap Retail Support reserves the right to make changes without prior notice. No part of this publication may be copied without the express written permission of Nedap Retail Support, Parallelweg 2d, 7141 DC Groenlo, Netherlands. Trademarks Nedap, the Nedap logo, Nedap EASi/Net and the Nedap EASi/Net are registered trademarks of Nedap N.V. Groenlo. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Printed in the Netherlands TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Technical Support: support-rs@nedap.com H. Hammer +31 (0) 544-47 15 19 hans.hammer@nedap.com H. Broekhuis +31 (0) 544-47 15 02 han.broekhuis@nedap.com Visitor’s address: Nedap Retail Support Parallelweg 2d Groenlo Netherlands Postal address: Nedap Retail Support Postbus 102 7140 AC Groenlo Fax +31 (0) 544-46 58 14 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Table of content Technical Support: Visitor’s address: Postal address: Fax Table of content TDC/SDC accessories TDC DUC Adjusting the dip switch SW1 Scope settings Connector K3 TDC Buzzer Adjusting the buzzer volume TDC Buzduc Connector K3 Release versions Two- and four way splitters EASiTM/Net 10 10 Filters 11 11 11 11 11 11 11 TDC Unit - 2 way splitter / 4 way splitter 2 way splitter / 4 way splitter - Antenna 2 way splitter / 4 way splitter - DUC 2 way splitter / 4 way splitter DUC - Add On antenna Maximum cable length Examples Version 1 12 Examples Version 2 13 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support TDC/SDC accessories For the TDC / SDC are the following accessories available: • • • • • TDC DUC TDC Buzzer TDC BuzDuc Two-way Splitter Four-way Splitter TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support TDC DUC This is a 50 ohms to O-shape (scanner) antenna coupling-unit. X4 X3 K1 Ground K3 X5 SW1 The DUC is used to connect an O-shape antenna to a deactivator. It contains a four-fold dipswitch to switch four tuning capacitors. In this way it is possible to optimally adapt in 16 steps. With the present capacitors O-shapes of 450 uH up to 3500uH can be accomodated. This range is sufficient to accomodate the normal O-shape- and scanner antennas. With jumper X3 it is possible to connect the system ground to the ground of the housing if necessary. It is not recommended to do this to avoid ground loops. As a default factory setting, this jumper is not placed. Jumper X3 X4 X5 Default setting off off on Application Ground to housing (jumper is present on PCB) X4 Off, X5 On, attenuation 3Db X4 On, X5 Off, attenuation 0Db Adjusting the dip switch SW1 Mount the preferred antenna loop and connect it to the DUC. • The DUC must be as close as possible to the loop (maximum distance is 30cm) • The wires to the DUC must be twisted Connect the DUC to the TDC. Turn on the TDC and choose for the antenna to be adjusted, in the hand terminal mux menu. Connect the scope to connector K9 and put jumper K8 to position 2-3. TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Scope settings 0,5V/div, 200uS/div. Take the channel with the directional coupler test cable. Put the four dipswitches in the “Off” position. A directional coupler signal with a maximum of 3Vtt is visible. Choose a combination of switch settings at which the directional coupler is as small as possible. ( > 500mVtt). This will be the most optimal setting. OST/Builder At the terminal screen (7-7-2) use the options 3 or 4 to view the directional coupler signal. Attenuate the DUC by using the dipswitch on the (Buz-)DUC PCB and the OS/T Builder. Try to get the blue line as horizontal as possible Connector K3 The add-on antenna will be connected to connector K3. Version 1: two pole connector The wires of the loop antenna will be connected to the two poles of the connector. Version 2: three pole connector (April 2004) The shielding of the cable will be connected to the middle pole, the other two wires to the other two poles of the connector. TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support TDC Buzzer P1 K1 X3 K2 The TDC contains two independent deactivator channels. When both channels are used, it is desired to have a sound at the antenna. The TDC buzzer is used to create sound when an event occurs. It will be placed in the coax cable going to the antenna and will be activated by the TDC. The buzzer volume is adjustable with pot-meter P1. With jumper X3 the system ground can be connected with the ground of the housing. It is recommended not to do this to avoid ground loops. By factory default this jumper is not placed. Adjusting the buzzer volume Mount the TD Buzzer and connect the antenna to the TDC. In the hand held terminal buzzer test menu the buzzer can be tested. Adjust P1 to the desired volume. TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support TDC Buzduc P1 X4 X3 K1 K3 SW1 X5 The TDC Buzduc is a combination of the TDC Duc and TDC Buzzer. With the TDC Buzduc a hand- or flatbed scanner antenna with a local buzzer can be realized. The DUC is meant to connect an O-shape antenna to a deactivator. It contains a four-fold dipswitch to switch four tuning capacitors. In this way it is possible to optimally adapt in 16 steps. With the present capacitors O-shapes of 450uH up to 3500uH can be adapt. This range is sufficient to adapt the normal O-shape- and scanner antennas. The buzzer volume is adjustable with pot-meter P1. With jumper X3 the system ground can be connected with the ground of the housing. It is recommended not to do this to avoid ground loops. By factory default this jumper is not placed. Jumper X3 X4 X5 Default setting off off on Application Ground to housing (jumper is present on PCB) X4 Off, X5 On, attenuation 3Db X4 On, X5 Off, attenuation 0Db Dip switch adjustments: Same as TDC DUC Buzzer volume adjustments: Same as TDC Buzzer Connector K3 The add-on antenna will be connected to connector K3. Release versions Version 1: two pole connector K3 The wires of the loop antenna will be connected to the two poles of the connector. Version 2: three pole connector K3 (>April 2004) The shielding of the cable will be connected to the middle pole, the other two wires to the other two poles of the connector. TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Two- and four way splitters The two- and four way splitters are used to expand the coaxial cable from a channel of the TDC to for two or four deactivator antennas. EASiTM/Net It is not possible to watch the data of one specific antenna in EASiTM/Net. The counting will be done over the entire group of antenna’s which are connected through the splitter to one channel of the TDC. TDC Standalone Powersplitter 4x Powersplitter 4x Dummyload Example:TDC with 2 four way splitters, 7 add-on antenna’s and 7 TDC Ducs or 7 TDC Buzducs and a dummyload for the last channel 10 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Filters TDC Unit - 2 way splitter / 4 way splitter (Belden 9907) One filter at the TDC, one filter at the splitter and every 9 meters one filter. 2 way splitter / 4 way splitter - Antenna (Belden 9907) Every 9 meters one filter. 2 way splitter / 4 way splitter - DUC (Belden 9907) A filter at the DUC and every 9 meters one filter. 2 way splitter / 4 way splitter Use a 50 Ohm dummy load on every unused output of the splitter is not in use. DUC - Add On antenna No filter, distance not longer then 30 centimeter. Maximum cable length The maximum cable length from the output of the TDC to the antenna is 15 meters. A splitter must be placed as close as possible to the antennas. 11 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Examples Version 1 Examples how to connect deactivator antennas to the TDC. Version 1 Duc’s and BuzDuc’s are used. TDC = Filter Sync Sync Master / slave Two way Splitter Four way Splitter Deactivator antenna Dummy Load TDC BuzDuc (Version 1) Loop antenna Deactivator antenna TDC Buzzer TDC Duc (Version 1) Loop antenna Add on antenna TDC Duc (Version 1) 12 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support Examples Version 2 Examples how to connect deactivator antennas to the TDC. Version 2 Duc’s and BuzDuc’s are used. TDC = Filter Sync Sync Master / slave Two way Splitter Four way Splitter Deactivator antenna Dummy Load TDC BuzDuc (Version 2) Loop antenna Shielding Deactivator antenna TDC Buzzer TDC Duc (Version 2) Loop antenna Add on antenna TDC Duc (Version 2) 13 TDC Duc – Buzzer - BuzDuc V1.60 | Nedap Retail Support
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 13 Page Layout : OneColumn XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:2a79d3f4-a4cf-479c-88c8-2ef3c0de99ee Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2004:09:08 09:53:45+02:00 Create Date : 2004:09:08 09:52:41+02:00 Metadata Date : 2004:09:08 09:53:45+02:00 Document ID : uuid:a6f68847-6136-4160-b0f0-c3496ce3161e Format : application/pdf Title : TDC Duc - Buzzer- Buzduc V1.60 Creator : Nedap Retail Support - GO Description : TDC Duc - Buzzer- Buzduc V1.60 - September 2004 Author : Nedap Retail Support - GO Subject : TDC Duc - Buzzer- Buzduc V1.60 - September 2004EXIF Metadata provided by EXIF.tools