Nedap N V VP1103 Inductive Card Reader User Manual

N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Card Reader

User Manual

  Panel Reader  VP1103         Manual article number 5277078               October 2010 / Manual version 1.1Service manual For installation, operation and service
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 Preface This manual describes the installation, operation, troubleshooting and maintenance of the Panel reader. Read this manual entirely and when installing, carefully follow the instructions step by step as described in the manual. Pictograms  Please pay extra attention here. This pictogram indicates an important subject.   Version overview  Manual version 1.0 / May 2010  First release. Manual version 1.1 / October 2010  Wiring adjustment.          This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher.  © Nedap N.V., AGRI  P.O. Box 104 NL-7140 AC GROENLO The Netherlands                 Model: VP1103         IC: 1444A-VP1103 and FCC ID: CGDVP1103 Compliance statements This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et  (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de cet appareil. Warning (part15.21) Changes or modifications not expressly approved by party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which can be delivered with the System.
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 Table of contents Preface and Version overview Table of contents 1. Introduction .........................................................................................................................1 1.1. Description ............................................................................................................................1 1.2. Functioning............................................................................................................................2 2. Installing the VP1103 Panel reader ...................................................................................3 2.1. Mounting the VP1103 Panel reader......................................................................................3 2.2. Connecting to a PC or a weight scale via RS232.................................................................4 2.2.1. Connecting RS232 via a Sub-D connector..............................................................4 2.2.2. Connecting RS232 via a Velos Panel reader cable.................................................4 2.3. Connecting to a Velos VPU via CAN communication...........................................................5 2.3.1. Connecting one VP1103 Panel reader ....................................................................5 2.3.2. Connecting several VP1103 Panel readers to a Velos VPU ...................................6 3. Starting up operation..........................................................................................................7 3.1. Turn on the power.................................................................................................................7 3.2. Checking the VP1103 Panel reader .....................................................................................7 3.2.1. Checking the CAN communication with an VPU .....................................................7 3.2.2. Checking the RS232 connection to a PC ................................................................7 4. Maintenance, malfunction and disposal...........................................................................8 4.1. Maintenance..........................................................................................................................8 4.2. Malfunction............................................................................................................................8 4.3. Disposal ................................................................................................................................8 Appendix A Technical specifications....................................................................................9 Appendix B Corridor requirements.....................................................................................10
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 1  1. Introduction The VP1103 Panel reader identifies RFID ear tags attached to individual animals. The identification can be used for registration of the animals that have passed the Panel reader unit (VP1103). A weight scale can optionally be connected to the Panel reader.  This device complies with Part 15 of the FCC Rules and to RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1.1. Description The VP1103 Panel reader system consists of a Panel reader unit that is connected to a VPU using CAN communication or a connection to a PC or a weight scale through RS232.                  1. Panel reader unit VP1103 2. Power supply VP2001 and VPU VP8001 3. Optional PC 4. Optional Weight scale 5. Optional Router and switch 6. Internet 7. RS232 connection 8. CAN communication 9. LAN connection via UTP cat5 cable  Figure 1. Overview VP1103 Panel reader system  98731Weight scale 4 OR 15633OR 2 VPUVP2001OR
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 2  1.2. Functioning The VP1103 Panel reader creates a magnetic field around the antenna that is used to identify the tags on ISO frequency 134.2 kHz. The Panel reader is connected to a VPU using CAN communication or to a PC or a weight scale through RS232. The Panel reader identifies animals that pass the Panel reader unit. When an animal is identified by the Panel reader, the tag number will be dumped.         1.  VP1103 Panel reader unit  2.  Responder number (animal identification) 3. Tag number dump    Figure 2. Connection between the Panel reader and the dumped tag numbers The tag numbers are stored via CAN communication in the VPU or dumped according to the ISO protocol 11784/11785 via an RS232 connection in e.g. the Windows Hyper Terminal communication program.  3  2 1
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 3  2.  Installing the VP1103 Panel reader 2.1.  Mounting the VP1103 Panel reader Installation and service should be done only by trained personnel. Always turn off the main power when working on the de electrical installation. Keep animals away from the antenna during installation and service. Close all covers when ready with installation or service.  See Appendix A for technical specifications before mounting. See Appendix B for corridor requirements.  Mount the Panel reader unit firmly on a wall or at a (non metal) frame.   Mounting requirements: 1. The Panel reader must not be mounted close to any iron. This will influence the performance of the antenna. 2. The Panel reader must not be mounted close to electrical equipment with background noise. This can disturb the antenna. 3. The Panel reader must be mounted on a wall close to a stable power supply. 4. The Panel reader must be mounted > 1.5 m. from electrical cables or power supply.  5. The Panel reader may not be exposed to direct sunlight.          Example mounting positions Drill zone at least 4 cm from the sides  Figure 3. Mounting positions on rear view VP1103 Panel reader Mount the Panel reader in 4 positions with screws, bolts, and plugs etc. suitable to support the Panel reader. Use a large washer behind the bolt/screw to give extra support. Use a screw or washer with a minimum head diameter of 18 mm. The size of the holes in the antenna must be corresponding with the size of the bolts or screws that are used.  Don’t damage the antenna when drilling holes for mounting the Panel reader. This could damage the electronics and affect the functioning of the Panel reader. Keep a minimum drill distance of 4 cm from the sides.   Install cables and power supplies / transformers > 1.5 m. from the Panel reader if possible.
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 4  2.2.  Connecting to a PC or a weight scale via RS232 2.2.1.  Connecting RS232 via a Sub-D connector Connect a PC or a weight scale to the VP1103 Panel reader RS232 Sub-D connection from the connector. Use an extension cable (art. nr 7707037) of 4 meters to extend the cable if necessary.     OR    1.  RS232 connection to PC 2.  RS232 connection to weight scale or other device 3.  Connector 4.  Adaptor Figure 4. VP1103 Panel reader RS232 connection 2.2.2.  Connecting RS232 via a Velos Panel reader cable Connect a PC or a weight scale or other device to the Panel reader via a Velos Panel reader cable (art.nr.7707029). This cable can also be used for connection to a VPU. Shortening of the Velos Panel reader cable is allowed.     Use an extension cable (art. nr 7707037) of 4 meters to extend the Velos Panel reader cable if necessary.    VP1103    PC or Weight scale  Shield   - Black  - - Red  +  12-27 V DC Green  (TxD) RxD Green / White  (RxD) TxD Velos Panel reader cable   Red  +  Input voltage 12-27 V DC Black  -  Minus Blue  CH Not connected Blue / White  CL Not connected Shield   Shielding connected to minus Orange  ~  Synchronization (antenna) HDX Orange / White  ~  Synchronization (antenna) HDX Green  TxD  TxD RS232 Communication, normally connected to RxD from PC Green / White  RxD  RxD RS232 Communication, normally connected to TxD from PC   Also connect the minus to PC when using RS232 communication 12 Weight scale 3 4
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 5  2.3.  Connecting to a Velos VPU via CAN communication 2.3.1.  Connecting one VP1103 Panel reader Connect the Panel reader cable (art.nr.7707029) to the VPU connectors.                     Shortening of the Velos Panel reader cable (art.nr.7707029) is allowed. Use an extension cable (art. nr 7707037) of 4 meters to extend the cable if necessary.   VPU   VP1103 Orange / White  ~  Orange /White Orange  ~  Orange Shield    Shield Blue / White  CL  Blue / White Blue  CH  Blue Black  -  Black Red  +  Red  Not connected Green  Not connected Green / White VP8001 VPU  Power supply (VP2001) LAN to PC
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 6  2.3.2.  Connecting several VP1103 Panel readers to a Velos VPU Connect the Panel readers VP1103 to the Velos connection boxes.   VP1103VP1103VP1103 VP1103 VP8001 VPUMax 80m From VPU to last VP1103 Velos cable part no. 7705310End resistor Only used at last box  Velos cable Velos cable Velos cablePower indicator Velos cable        VP1103 Orange/white   ~   Orange/white Orange   ~   Orange Shield     Shield Blue/white   CL  Blue/white Blue   CH  Blue Black   -   Black Red   +   Red Power supply (VP2001) Max = 2x4A LAN to PC Keep a distance of more than 2 meter between the VP1103 Panel readers to prevent interference
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 7  3.  Starting up operation The Panel reader is pre-tuned and ready for use. 3.1.  Turn on the power For an RS232 connection: Put the adaptor into an electric socket. For CAN communication to a VPU: Turn on the Power supply VP2001. 3.2.  Checking the VP1103 Panel reader 3.2.1.  Checking the CAN connection to the VPU Check the status of the Panel reader that is connected to a VPU in the Velos VPU program web page Maintenance > V-packs – Overview.   3.2.2.  Checking the RS232 connection to a PC Check the operation of the VP1103 Panel reader that is connected to a PC with the Hyper Terminal program. Set the baud rate of the Hyper Terminal communication program to 9600. The other settings are default.  The tags numbers that are identified by the Panel reader will be displayed in the screen according to the ISO protocol 11784/11785.
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 8  4.  Maintenance, malfunction and disposal 4.1. Maintenance Check the operation of the Panel reader regularly.  No regular maintenance is required.  The Panel reader can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids. 4.2. Malfunction If the Panel reader VP1103 is connected to a VPU, view the actual state of the Panel reader in the webpage Maintenance > V-packs – Overview. A reduced antenna performance may be caused by a strong electrical background noise. Install cables and power supply / transformers > 1.5 m. from the Panel reader. 4.3. Disposal At discard dispose of materials from the Panel reader in accordance with the current environmental rules of the state or local governing authorities.
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 9  Appendix A  Technical specifications Measurements VP1103 Panel reader Total height  595 mm Total width   495 mm Depth   30 mm Specifications for transport / installation  Weight VP1103 Panel reader  6.2 kg Electrical supply Main supply    100V - 240V Frequency  50 – 60 Hz Input voltage (always use Nedap power supply)  12 - 27 V DC Input current (mA) depends on input voltage  0.75 – 0.5 A Environmental Operating temperatures  - 10°C / + 50°C Transport / storage temperatures  - 25°C / + 70°C Relative humidity (non condensing)  10°C / 90% Enclosure protection class (when cover and cables installed correctly)  IP67 The Panel reader may not be exposed to direct sunlight. The Panel reader must always be transported and stored dry and frost-free. Other specifications  CAN  CAN-bus communication 125 kBit  Power  Power consumption 225 mA with antenna switched on (i.c.o. 500 V) Protected against reverse connection power supply Software  Downloadable by the CAN network Antennas  Internal fixed antenna Detection distance  Depending on used tags Synchronization  Synchronization according to ISO 11785, ISO 24631-7
 VP1103-200PM-00GB-Panel reader                                           Manual version 1.1 / Page 10  Appendix B  Corridor requirements The maximum corridor width at the Panel reader location will be different for each animal sort and breed. Make sure the corridor is not too wide at the Panel reader location.                   The maximum width of the corridor is essential to achieve a proper working system. Animals should never be able to pass each other, turn around or walk in the wrong direction. INThe identification distance of the antenna field Maximum corridor entrance width: Allow passage of 1 animal at the time. Keep the corridor as narrow as possible.  RFID Eartags : Attach all ear tags on same side of animals (left in this example). The antenna must be mounted at the side where the tag is attached. The identification distance of the antenna varies per installation. It depends on the iron and the background noise in the ISO- reader area. Maximum width  1 animal wide Minimum length 1 animal long

Navigation menu