Nedap N V VP1103 Inductive Card Reader User Manual
N. V. Nederlandsche Apparatenfabriek NEDAP Inductive Card Reader
User Manual
Service manual For installation, operation and service Panel Reader VP1103 Manual article number 5277078 October 2010 / Manual version 1.1 Preface This manual describes the installation, operation, troubleshooting and maintenance of the Panel reader. Read this manual entirely and when installing, carefully follow the instructions step by step as described in the manual. Pictograms Please pay extra attention here. This pictogram indicates an important subject. Version overview Manual version 1.0 / May 2010 First release. Manual version 1.1 / October 2010 Wiring adjustment. Model: VP1103 IC: 1444A-VP1103 and FCC ID: CGDVP1103 Compliance statements This device complies with part 15 of the FCC Rules and to RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil se conforme aux normes RSS210 exemptés de license du Industry Canada. L'opération est soumis aux deux conditions suivantes: (1) cet appareil ne doit causer aucune interférence, et (2) cet appareil doit accepter n'importe quelle interférence, y inclus interférence qui peut causer une opération non pas voulu de cet appareil. Warning (part15.21) Changes or modifications not expressly approved by party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which can be delivered with the System. This information is furnished for guidance, and with no guarantee as to its accuracy or completeness; its publication conveys no license under any patent or other right, nor does the publisher assume liability for any consequence of its use; specifications and availability of goods mentioned in it are subject to change without notice; it is not to be reproduced in any way, in whole or in part, without the written consent of the publisher. © Nedap N.V., AGRI P.O. Box 104 NL-7140 AC GROENLO The Netherlands VP1103-200PM-00GB-Panel reader Manual version 1.1 Table of contents Preface and Version overview Table of contents 1. Introduction .........................................................................................................................1 1.1. Description ............................................................................................................................1 1.2. Functioning............................................................................................................................2 2. Installing the VP1103 Panel reader ...................................................................................3 2.1. Mounting the VP1103 Panel reader......................................................................................3 2.2. Connecting to a PC or a weight scale via RS232.................................................................4 2.2.1. Connecting RS232 via a Sub-D connector ..............................................................4 2.2.2. Connecting RS232 via a Velos Panel reader cable.................................................4 2.3. Connecting to a Velos VPU via CAN communication...........................................................5 2.3.1. Connecting one VP1103 Panel reader ....................................................................5 2.3.2. 3. Connecting several VP1103 Panel readers to a Velos VPU ...................................6 Starting up operation..........................................................................................................7 3.1. Turn on the power.................................................................................................................7 3.2. Checking the VP1103 Panel reader .....................................................................................7 3.2.1. Checking the CAN communication with an VPU .....................................................7 3.2.2. 4. Checking the RS232 connection to a PC ................................................................7 Maintenance, malfunction and disposal...........................................................................8 4.1. Maintenance..........................................................................................................................8 4.2. Malfunction............................................................................................................................8 4.3. Disposal ................................................................................................................................8 Appendix A Technical specifications....................................................................................9 Appendix B Corridor requirements .....................................................................................10 VP1103-200PM-00GB-Panel reader Manual version 1.1 1. Introduction The VP1103 Panel reader identifies RFID ear tags attached to individual animals. The identification can be used for registration of the animals that have passed the Panel reader unit (VP1103). A weight scale can optionally be connected to the Panel reader. This device complies with Part 15 of the FCC Rules and to RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1.1. Description The VP1103 Panel reader system consists of a Panel reader unit that is connected to a VPU using CAN communication or a connection to a PC or a weight scale through RS232. 1. Panel reader unit VP1103 2. Power supply VP2001 and VPU VP8001 Weight OR scale 3. Optional PC 4. Optional Weight scale 5. Optional Router and switch 6. Internet OR 7. RS232 connection 8. CAN communication 9. LAN connection via UTP cat5 cable OR VP2001 VPU Figure 1. Overview VP1103 Panel reader system VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 1 1.2. Functioning The VP1103 Panel reader creates a magnetic field around the antenna that is used to identify the tags on ISO frequency 134.2 kHz. The Panel reader is connected to a VPU using CAN communication or to a PC or a weight scale through RS232. The Panel reader identifies animals that pass the Panel reader unit. When an animal is identified by the Panel reader, the tag number will be dumped. 1. VP1103 Panel reader unit 2. Responder number (animal identification) 3. Tag number dump Figure 2. Connection between the Panel reader and the dumped tag numbers The tag numbers are stored via CAN communication in the VPU or dumped according to the ISO protocol 11784/11785 via an RS232 connection in e.g. the Windows Hyper Terminal communication program. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 2 2. Installing the VP1103 Panel reader 2.1. Mounting the VP1103 Panel reader Installation and service should be done only by trained personnel. Always turn off the main power when working on the de electrical installation. Keep animals away from the antenna during installation and service. Close all covers when ready with installation or service. See Appendix A for technical specifications before mounting. See Appendix B for corridor requirements. Mount the Panel reader unit firmly on a wall or at a (non metal) frame. Mounting requirements: 1. The Panel reader must not be mounted close to any iron. This will influence the performance of the antenna. 2. The Panel reader must not be mounted close to electrical equipment with background noise. This can disturb the antenna. 3. The Panel reader must be mounted on a wall close to a stable power supply. 4. The Panel reader must be mounted > 1.5 m. from electrical cables or power supply. 5. The Panel reader may not be exposed to direct sunlight. Example mounting positions Drill zone at least 4 cm from the sides Figure 3. Mounting positions on rear view VP1103 Panel reader Mount the Panel reader in 4 positions with screws, bolts, and plugs etc. suitable to support the Panel reader. Use a large washer behind the bolt/screw to give extra support. Use a screw or washer with a minimum head diameter of 18 mm. The size of the holes in the antenna must be corresponding with the size of the bolts or screws that are used. Don’t damage the antenna when drilling holes for mounting the Panel reader. This could damage the electronics and affect the functioning of the Panel reader. Keep a minimum drill distance of 4 cm from the sides. Install cables and power supplies / transformers > 1.5 m. from the Panel reader if possible. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 3 2.2. Connecting to a PC or a weight scale via RS232 2.2.1. Connecting RS232 via a Sub-D connector Connect a PC or a weight scale to the VP1103 Panel reader RS232 Sub-D connection from the connector. Use an extension cable (art. nr 7707037) of 4 meters to extend the cable if necessary. 1. RS232 connection to PC 2. RS232 connection to weight scale or other device 3. Connector OR Weight scale 4. Adaptor Figure 4. VP1103 Panel reader RS232 connection 2.2.2. Connecting RS232 via a Velos Panel reader cable Connect a PC or a weight scale or other device to the Panel reader via a Velos Panel reader cable (art.nr.7707029). This cable can also be used for connection to a VPU. Shortening of the Velos Panel reader cable is allowed. VP1103 Shield Black Red Green Green / White Velos Panel reader cable Red Black Blue CH Blue / White CL Shield Orange Orange / White Green TxD Green / White RxD (TxD) (RxD) PC or Weight scale 12-27 V DC RxD TxD Input voltage 12-27 V DC Minus Not connected Not connected Shielding connected to minus Synchronization (antenna) HDX Synchronization (antenna) HDX TxD RS232 Communication, normally connected to RxD from PC RxD RS232 Communication, normally connected to TxD from PC Also connect the minus to PC when using RS232 communication Use an extension cable (art. nr 7707037) of 4 meters to extend the Velos Panel reader cable if necessary. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 4 2.3. Connecting to a Velos VPU via CAN communication 2.3.1. Connecting one VP1103 Panel reader Power supply (VP2001) VPU Orange / White Orange Shield Blue / White Blue Black Red CL CH Not connected Not connected VP8001 VPU LAN to PC Connect the Panel reader cable (art.nr.7707029) to the VPU connectors. VP1103 Orange /White Orange Shield Blue / White Blue Black Red Green Green / White Shortening of the Velos Panel reader cable (art.nr.7707029) is allowed. Use an extension cable (art. nr 7707037) of 4 meters to extend the cable if necessary. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 5 2.3.2. Connecting several VP1103 Panel readers to a Velos VPU VP8001 VPU Power supply (VP2001) Max = 2x4A LAN to PC Connect the Panel readers VP1103 to the Velos connection boxes. Max 80m From VPU to last VP1103 Velos cable part no. 7705310 Velos cable VP1103 VP1103 Power indicator VP1103 Velos cable Orange/white Orange Shield Blue/white Blue Black Red Velos cable Velos cable Keep a distance of more than 2 meter between the VP1103 Panel readers to prevent interference VP1103 CL CH VP1103-200PM-00GB-Panel reader VP1103 Orange/white Orange Shield Blue/white Blue Black Red End resistor Only used at last box Manual version 1.1 / Page 6 3. Starting up operation The Panel reader is pre-tuned and ready for use. 3.1. Turn on the power For an RS232 connection: Put the adaptor into an electric socket. For CAN communication to a VPU: Turn on the Power supply VP2001. 3.2. Checking the VP1103 Panel reader 3.2.1. Checking the CAN connection to the VPU Check the status of the Panel reader that is connected to a VPU in the Velos VPU program web page Maintenance > V-packs – Overview. 3.2.2. Checking the RS232 connection to a PC Check the operation of the VP1103 Panel reader that is connected to a PC with the Hyper Terminal program. Set the baud rate of the Hyper Terminal communication program to 9600. The other settings are default. The tags numbers that are identified by the Panel reader will be displayed in the screen according to the ISO protocol 11784/11785. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 7 4. Maintenance, malfunction and disposal 4.1. Maintenance Check the operation of the Panel reader regularly. No regular maintenance is required. The Panel reader can be cleaned with water and sponge. Avoid (aggressive) cleaning liquids. 4.2. Malfunction If the Panel reader VP1103 is connected to a VPU, view the actual state of the Panel reader in the webpage Maintenance > V-packs – Overview. A reduced antenna performance may be caused by a strong electrical background noise. Install cables and power supply / transformers > 1.5 m. from the Panel reader. 4.3. Disposal At discard dispose of materials from the Panel reader in accordance with the current environmental rules of the state or local governing authorities. VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 8 Appendix A Technical specifications Measurements VP1103 Panel reader Total height 595 mm Total width 495 mm Depth 30 mm Specifications for transport / installation Weight VP1103 Panel reader 6.2 kg Electrical supply Main supply 100V - 240V Frequency 50 – 60 Hz Input voltage (always use Nedap power supply) 12 - 27 V DC Input current (mA) depends on input voltage 0.75 – 0.5 A Environmental Operating temperatures - 10°C / + 50°C Transport / storage temperatures - 25°C / + 70°C Relative humidity (non condensing) 10°C / 90% Enclosure protection class (when cover and cables installed correctly) IP67 The Panel reader may not be exposed to direct sunlight. The Panel reader must always be transported and stored dry and frost-free. Other specifications CAN CAN-bus communication 125 kBit Power Power consumption 225 mA with antenna switched on (i.c.o. 500 V) Protected against reverse connection power supply Software Downloadable by the CAN network Antennas Internal fixed antenna Detection distance Depending on used tags Synchronization Synchronization according to ISO 11785, ISO 24631-7 VP1103-200PM-00GB-Panel reader Manual version 1.1 / Page 9 Appendix B Corridor requirements The maximum corridor width at the Panel reader location will be different for each animal sort and breed. Make sure the corridor is not too wide at the Panel reader location. The maximum width of the corridor is essential to achieve a proper working system. Animals should never be able to pass each other, turn around or walk in the wrong direction. Maximum width 1 animal wide Minimum length 1 animal long IN VP1103-200PM-00GB-Panel reader Maximum corridor entrance width: Allow passage of 1 animal at the time. Keep the corridor as narrow as possible. RFID Eartags : Attach all ear tags on same side of animals (left in this example). The antenna must be mounted at the side where the tag is attached. The identification distance of the antenna field The identification distance of the antenna varies per installation. It depends on the iron and the background noise in the ISOreader area. Manual version 1.1 / Page 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2010:11:02 09:22:42+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2011:12:21 20:40:59+01:00 Metadata Date : 2011:12:21 20:40:59+01:00 Format : application/pdf Creator : l.jansen Title : Microsoft Word - VP1103 Panel reader manual 1.1 _5277078_.doc Document ID : uuid:e9cd4c74-b7d8-4470-9d2f-23f5cf1f4a0e Instance ID : uuid:4c88a6ff-4b9f-436a-9b1c-24080adefaae Page Count : 14 Author : l.jansenEXIF Metadata provided by EXIF.tools