New Centurion Solutions NCS03010910 HANDHELD SECURITY DEVICE User Manual Project 623

New Centurion Solutions, Inc. HANDHELD SECURITY DEVICE Project 623

Contents

Users Manual

THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.   Elliott Tech, LLC   IREP Assembly Manual IREP New Centurion Solutions    Project Number:  776 Reference:  776-91-03-REV-.docx Original Document:  March 1, 2011 Revision A: March 16, 2011    Prepared for: Prepared by: New Centurion Solutions, Inc. Greg Williams 3011 Spring Garden St. Suite E Greensboro, NC  27403 (336) 617-5410 GWilliams@newcenturionsolutions.com Elliott Tech, LLC 346 Raleigh Street Holly Springs, NC 27540  (919) 342-6899 (888) 631-1795  Fax s.elliott@elliotttech.com
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    ii Revision Page  Rev Description Section  A FCC Notification 3
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    iii Contents 1. Equipment List ......................................................................................................... 4 2. Assembly Instructions .............................................................................................. 5 3. FCC Notification ...................................................................................................... 7
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    4 1. EQUIPMENT LIST A. IREP Enclosure - Inside (1) B. Tenergy Battery (1)   C. IREP Enclosure - Outside (1) D. Double Sided Tape   E. IREP Enclosure - Screws (4) F. IREP PCB (1)   G. Coaxial Cable RF Plug-SMA Jack (1) H. SMA Antenna (1)
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    5 2. ASSEMBLY INSTRUCTIONS To begin, check the parts available against the equipment list, identifying any missing parts.  If all parts are accounted for, proceed to the instructions below to begin assembling the indoor repeater (IREP).  Step 1: The inside enclosure (A) should come inside of the outside enclosure (C) as indicated in the figure below.  Place the PCB (F) over the inside enclosure so that the LED’s line up with the three consecutive holes and that the holes in each corner of the PCB line up over the screw holes on the enclosure.  Insert the enclosure screws (E) into each corner of the PCB attaching the board to the enclosure.        Step 2: Put the washer on the end of the RF cable (G) with the jack and feed it through the opening in the enclosure from the inside out.  Rotate the nut clockwise around the outside of the RF jack until it is flush against the enclosure.             Step 1 Step 2
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    6 Step 3: Take the SMA plug end of the RF cable and attach it to the RF port labeled J1 on the PCB by laying the plug over the port and pressing down.  The plug should snap right into place.      Step 4: Attach the SMA Antenna to the RF jack by screwing it in clockwise to the outside of the enclosure.       Step 5: Insert the Tenergy battery (B) connector into the 3 pin header on the PCB beside the “on” switch.  After doing so, apply a piece of double sided tape (D) to either side of the battery, and press the battery against the metal shields on the PCB.     Step 3 Step 4 Step 5
IREP Assembly Manual    776-91-03-REV-A.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    7 3. FCC NOTIFICATION NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.  SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.  THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

Navigation menu