New Centurion Solutions NCS03010910 HANDHELD SECURITY DEVICE User Manual Project 623

New Centurion Solutions, Inc. HANDHELD SECURITY DEVICE Project 623

Contents

Installation Manual

THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.   Elliott Tech, LLC   IREP Installation Manual IREP New Centurion Solutions    Project Number:  776 Reference:  776-91-06-REV-IREP_INSTALLATION_MANUAL.docx Original Document:  March 1, 2011 Revision A: March 16, 2011       Prepared for: Prepared by: New Centurion Solutions, Inc. Greg Williams 3011 Spring Garden St. Suite E Greensboro, NC  27403 (336) 617-5410 GWilliams@newcenturionsolutions.com Elliott Tech, LLC 346 Raleigh Street Holly Springs, NC 27540  (919) 342-6899 (888) 631-1795  Fax s.elliott@elliotttech.com
IREP Installation Manual   776-91-06-REV-A_IREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    ii Revision Page  Rev Description Section  A FCC Notification 3
IREP Installation Manual   776-91-06-REV-A_IREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    iii Contents 1. Equipment List ......................................................................................................... 4 2. Installation  Prerequisties ........................................................................................ 5 3. Installation Instructions .......................................................................................... 5 4. FCC Notification ...................................................................................................... 6
IREP Installation Manual   776-91-06-REV-A_IREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    4 1. EQUIPMENT LIST A. Antenna, helical short ¼ wave (1) B. IREP Assembly (1)   C. Double-gang box installation (pre-requisite) D. #6-32  pan  head  screw  (4)  –  included  with  IREP assembly   E. #6-32  x  1”  button-head  screw  (1)  –  included with IREP assembly
IREP Installation Manual   776-91-06-REV-A_IREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    5 2. INSTALLATION  PREREQUISTIES  Ensure that the following installation prerequisite is met:   Wiring and installation of double-gang box  3. INSTALLATION INSTRUCTIONS To begin, check the parts available against the equipment list, identifying any missing parts.  If all parts are accounted for, proceed to the instructions below to begin installing the IREP.  Step 1:  Identify the Antenna, helical short ¼ wave (A).  Screw the antenna into the gold coaxial antenna connector on the top of the IREP assembly (B).  Ensure that the antenna is screwed onto the connector snugly, but take care not to over-tighten the antenna as it will damage the connector or the IREP assembly enclosure.      Step 2:  Identify the power supply wires located within the double-gang installation.  Ensure that the positive and negative wires are identified before proceeding with the installation.    Identify the green and orange terminal block on the IREP Printed Circuit Board (PCB).  Note the “+” silkscreen market on the PCB just to the lower right of the terminal block.  Connect the positive power supply wire to the terminal block connection distinguished by the “+” marker, and connect the negative power supply wire to the opposite terminal block connection.   The green LED on the front of the IREP enclosure should illuminate when power is correctly connected.            Type-A (+) (-) Step 1 Step 2
IREP Installation Manual   776-91-06-REV-A_IREP_INSTALLATION_MANUAL.docx THE INFORMATION CONTAINED HEREIN IS PROPRIETARY TO NEW CENTURION SOLUTIONS, INC. AND SHALL NOT BE REPRODUCED OR DISCLOSED IN WHOLE OR IN PART FOR ANY DESIGN OR MANUFACTURE EXCEPT WHEN SUCH USER POSSESSES DIRECT, WRITTEN AUTHORIZATION FROM NEW CENTURION SOLUTIONS, INC.    6 Step 3:  Identify the #6-32 pan head screw (D).  Ensure that the outer half of the enclosure is detached from the inner half.  Secure the inner half of the IREP (connected to wires) assembly to the double-gang box with four of these screws.                 Step 4:  Identify the outer half of the IREP enclosure.  Secure this half over the first half using the #6-32 x 1” button-head screw (E) at the top center of the IREP.                   4. FCC NOTIFICATION NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.  SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.  THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Step 3 Step 4

Navigation menu