NiCOM USA NT350FP07 350W TRANSMITTER User Manual NT350
NiCOM USA 350W TRANSMITTER NT350
USERS MANUAL
TABLE OF CONTENTS CHAPTER 1 Transmitter General Description And Installation Procedures Page 2 Remote Control Feature Page 5 Analog telemetry Option Page 7 Programming the NT 350 Page 8 CHAPTER 2 Electrical Specifications Page 13 Mechanical Specifications Page 15 CHAPTER 3 350 W schematics and components list Page 16 CHAPTER 1 GENERAL DESCRIPTION NT 350 Transmitter - Exciter INTRODUCTION The NT-350-LCD is a highly integrated broadband solid-state Mos-Fet FM transmitter of 350W rated power, fitted in a 3 unit rack, which do not require any specific calibration to operate in the 87.5 ÷ 108 MHz frequency range. The unit is microprocessor controlled with an optional PC interface. Its compact size, high efficiency, wide mains range acceptance, low maintenance requirements and broadband construction, make this amplifier ideal in medium power repeaters, in unattended posts and as a reserve. Its sturdy, modular mechanical and electrical construction guarantees a high MTBF and an easy maintenance. The modules are easily identifiable and inspectable with few interconnections each with the other, through multi-pole connectors. The nominal RF output power is obtained over the full FM range is particularly stable against time, temperature and frequency variations being ALC regulated, with a front panel adjustment. The output power may be varied from a minimum level to the nominal level and the frequency varied over the full FM range, without retouching the drive power or any other adjustment than the ALC control. The output stage has a reverse intermodulation figure, which is lower than standard bipolar construction, due to the all Mos-Fet design and approaches that of tube equipment. A simple metering and alarm section completes the amplifier, permitting an easy check of the functioning with few, unambiguous readings. The front panel displays forward, reflected power and modulation measures. It is possible to change the frequency of the unit from the front panel, password protected. The whole assembly is designed in accordance with the CCIR, FCC and tighter international norms and conforms to the recent, strict requirements for EMI susceptance and emission. INSTALLATION After unpacking the unit, check for any mechanical damage or loose parts inside. If there is any transportation damage, inform the supplier immediately and do not put the module into operation. The applicable voltage is 110 or 220v depending on how the unit was ordered. Please check the back of the unit for the voltage that the unit was set to, and if it is the wrong one, please call Nicom for instruction on how to set the voltage. Ensure that the station’s ground system connections have a ground resistance of less than 5 ohms. The equipment’s rack or cabinet must be effectively grounded. Check that the transmitter’s main switch is off. Connect the power cord to the AC plug. STARTING PROCEDURE Connect the antenna cable to the ‘N’ type connector on the back of the unit. The antenna system must be set up to operate at the transmitter’s working frequency. ATTENTION Antenna matching is extremely crucial for FM transmitters. Operate this unit only after verifying good matching. Mismatching will decrease the communication distance and unduly stress the semiconductors. Turn on the transmitter. You should see the "WAIT" message appear on the LCD Display. After few seconds the green LED “PLL LOCK” should turn on. This indicates that the frequency is locked on the programmed value. In the display will appear a sequence of squares. After few more seconds the “RF ENABLE” green LED will come on. This indicates that RF power is being delivered to the output connector on the back. You can now increase the output power through the small trimpot located in the front panel and identified with " RF ADJ." Increase slowly till you reach the power you need; keep always an eye at the Reflected power reading to verify that the antenna is well operating. The indication of the reflected power is on the right side of the display "RFL". Once you have reached the desired power level, you should wait till the unit warms up (30 minutes) Now you can input modulation. For MONO operation connect your signal to the XLR connector or BNC, Depending on the model. Following the connecting instructions printed on the back of the transmitter and then regulate the input level with the apposite trimmer. For stereo input, use the BNC connector labeled “MPX”. Regulate the audio with the apposite trimmer. Note:Be sure that the modulation level is close to but not more than 75KHz. 75KHz is 100% modulation. Lower modulation level will decrease the S/N value while over-modulation (>100%) will cause distortion at the receiver and it is against current regulations. REMOTE CONTROL FEATURE The NT 350 is equipped with a 9 pin RS 232 connector that allows all the mains telemetry functions. The software is supplied with the unit and with this CD rom it's possible to monitor and to change the main parameters ot the NT 350 on the computer's screen. The NT 350 is also supplied with the interlock connector that allows to switch the power on and off simply by grounding the inner conductor of the BNC. NOTE: The CD (optional) contains the remote control software of the NT 350. If a CD was not ordered, please check Nicom website (www.NicomUsa.com) where the latest version of the software is available for download. REMOTE CONTROL SOFTWARE INSTALLATION The NT 350 comes with a Serial port RS 232. This port allows a Bi-Directional remote control of the unit from a PC. INSTALLING THE SOFTWARE 1. Insert the NT 350 CD-ROM into the CD drive. 2. Run Setup.exe file found in the main folder of the CD-ROM. The installation will continue automatically asking only for the name of the folder of the hard drive where the program will be installed. It will be necessary to reboot the computer. 3. Once installed, the Tx_Nicom program icon can be recalled by clicking : Start - Programs - Tx_Nicom icon. CONNECTING THE NT 350 The NT 350 is equipped with a Serial Port (RS232) in the rear panel. To connect the computer with the NT 350 we recommend standard serial cables Pin-to-Pin; the length of the cable must stay within 60 feet. REMEMBER TO CLOSE THE PROGRAM BEFORE REMOVING THE CONNECTING CABLE RUNNING THE PROGRAM Once the program is running, from the main screen it is necessary to click the POWER ON button; the screen will light up and a message" COMMUNICATION IN PROGRESS" will appear. After few seconds, on the left side of the screen, the operating frequency will appear together with all the other parameters. If not, check the Communication port setting (COM1-COM 2). To change it, click the File menu and then select "set Port". The other parameters shown on the screen are the following: 1. Temperature in Celsius ( remember that Farheneit is Celsius x 1.8 + 20) 2. Lock Indicator showing that PLL circuit of the unit is locked 3. On the Air showing that the unit is transmitting 4. RF Forward giving the amount of Watts radiated 5. RF Reflected giving the amount of reflected power On the right side of the screen there are four buttons that allow to modify the parameters: a. Send Button to be used after a change of frequency is made b. Set Frequency frequency on allows the change of frequency by clicking the new the keyboard on the left side of the screen c. Disconnect allows to disconnect the system d. RF On turns up and down the power An Analog telemetry option is available for installation as an option, to be specified at time of purchase. Below is a diagram of the connections on the RS232 port. NOTE: IF THE ANALOG TELEMETRY OPTION IS SELECTED AT TIME OF PURCHASE, THE REMOTE CONTROL SOFTWARE DESCRIBED BELOW WILL NOT WORK. NT 350 PROGRAMMING Connect a 50 ohm load or 50 ohm antenna to the RF output, connect the equipment into a mains supply (120 or 240 VAC). The equipment is factory pre-set to 50 W. Switch ON the power and the yellow V POWER LED will light. The Display will show: WAIT PROGRAM SETTING After 3 seconds the green PLL LOCK led will light and the Display will show an increasing bar. After a further 5 seconds the green ENABLE will light and there will be output power. At this point the Display will show the next parameter: • • • Level Modulation (MOD > Forward Power (FRW 50.0W); Reflected Power (RFL 0.4W). MOD > PW 50W PR 0.4W PROGRAM SETTING The default frequency is 98.000 MHz. To display the frequency push the SETTING key. In order to display the parameter push the SELECT key. Display Password The Password mode is factory set to enable, and is not possible change this setting. The default password is 1 2 3. The way for changing the password is the following: • Press the PROGRAM key for 3 seconds; PROGRAM PASSWORD 0123456789 • SETTING Press the PROGRAM key to move the underscore character position at the required digit, and press the SETTING key to confirm the digit. PASSWORD 0123456789 PROGRAM SETTING Repeat the same for the two remaining digits. *** PASSWORD 0123456789 • PROGRAM SETTING If the password is correct press the SETTING key to confirm, otherwise press the PROGRAM key to select again. CONFIRM (Y/N) ? N=SEL. Y=SET. PROGRAM SETTING If the password is not correct an error is displayed: ERROR PASSWORD PROGRAM SETTING After a few seconds the display will show the parameters again. When the password is correct, the display will show: NEW PASS . = SET. NEW FREQ . = PRG . PROGRAM SETTING To change the password press the SETTING key. To change the frequency press the PROGRAM key. • For changing the password proceed with the same method for the required password: NEW PASSWORD 0123456789 PROGRAM SETTING The confirmation password will be required. CONFIRMATION 0123456789 If the password is correct the display will show: STORED NEW PASSWORD PROGRAM SETTING PROGRAM SETTING 10 If the confirmation password is wrong the display will show: PROGRAM ERROR CONFIRMATION SETTING IMPORTANT NOTE ! BE CAREFUL ! Once the password is set, it must be remembered, otherwise neither the frequency nor the password can be reset and the unit will have to be returned to Nicom for resetting. Display Change of Frequency. • Press the PROGRAM key for 3 seconds and enter the correct password. At this point press again the SELECT key: NEW PASS . = SET. NEW FREQ . = PRG . • PROGRAM SETTING Press the PROGRAM key to change the desired digit and press the SETTING key to confirm it. FREQUENCY ? MHz 103.900 PROGRAM SETTING The underscore character indicates which digit can be change. To move the underscore character hit the PROGRAM key. 11 When the new frequency is chosen, then press the SETTING key confirm it. After a “WAIT CYCLE”, the display will show the parameters: MOD > PW 1000W PR 0.4W PROGRAM SETTING After 7 minutes the display light will switch off and the display will show: NICOM MHz 103.900 PROGRAM SETTING 12 CHAPTER 2 ELECTRICAL SPECIFICATIONS NT 350 TECHNICAL DATA Power output: Frequency of operation: reference RF output connector/ Impedance: Frequency Stability: 5 to 350 Watts continuously variable Sinthesized with TXCO crystal N Type / 50 Ohms Better than 5ppm (± 500 Hz) , 0 to Frequency Range: 87.5 - 108 Mhz Frequency programming: Modulation type: S/N Ratio (ref. to 50 Khz / 1000 Hz): Distortion, THD: Asyncronous AM S/N ratio: 100% AM Digitally in 10 Khz increments. Direct FM at the carrier frequency Mono > 70dB - Stereo > 65 dB. < 0.1 %, Typ. 0.05 % 65 dB below reference carrier with 50° C. Syncronous AM S/N ratio: DC input power: AC input power: Ambient Temperature Range: Spurious and Harmonic or Subharmonic Emissions: Stereo Separation COMPOSITE OPERATION Composite inputs MPX input MPX input impedance MPX input level Composite FM unweighed S/N ratio modulation, 75 or 50 usec deemphasis (no FM modulation present). 60 dB below reference carrier with 100% AM modulation (FM modulation ± 75 Khz). 48 V VDC 12 A 110-240 V (internally selectable) 0° to 50° C (+32° to +122° F) < -80 dB or better 55 dB @ 1 Khz four total, 1 for MPX and 3 for SCA 1 unbalanced bnc connector 2 K ohms 3,5 V p-p (1,237 Vrms/3.64 dBm) > 78 dB below ± 75 Khz deviation at 400 Hz 13 Composite Total Harmonic Distortion Composite Intermodulation Distortion Baseband Crosstalk stereo subchannel SCA Inputs SCA Input Impedance SCA Input Levels nominal for SCA Amplitude Response Crosstalk subchannel >65dB measured in a 30 Hz - 100Khz bandwidth with 75 usec de-emphasis (RMS) 0.05 % typical 0.05 %, measured with a 1 Khz and a 1.3 Khz tone, 1:1 ratio, at 100% modulation 30 Hz - 60 Khz within 0.15 dB main to stereo subchannel and to main > 55 dB ( 60 dB typical) 3 unbalanced BNC connectors 10 K Ohms 0 dBm (775 mV rms/ 2.2 V p-p) ± 75 Khz deviation, adjustable ± 0.8 dB, 40 Khz to 100 Khz 67 Khz SCA to main or to stereo 92 Khz SCA to main or to stereo subchannel >70 dB MONOAURAL OPERATION Audio Connector Audio Input Impedance Audio Input Level nominal for FM S/N Ratio XLR 600 Ohms balanced or unbalanced; 50 dB common mode suppression 0 dBm (775 mV rms/ 2.2 V p-p) ± 75 Khz deviation, adjustable > 70 dB below ± 75 Khz deviation at 400 Hz measured in a 30 Hz - 20Khz bandwidth with 75 usec de-emphasis (RMS) Audio Frequency Response ± 0.8 dB, 30 Hz to 15 Khz Intermodulation Distortion 0.05 %, measured with a 1 Khz and a 1.3 Khz tone, 1:1 ratio, at 100% modulation 14 MECHANICAL SPECIFICATIONS Chassis Dimensions: 132 mm (5.1") H 326 mm (12.83")D 445 mm (17.51) W Front panel dimensions: 483 mm (19") W 132 mm (5.1") H Ambient operating temperature: from 0 to + 50 C (+32 to +122 F) Humidity: 90% maximum, non condensing. Weight: 32 Lbs ( 14.5 Kg) Shipping Dimensions: 22" x 23" x 8" 15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2007:04:19 14:27:42-07:00 Modify Date : 2007:04:19 14:27:42-07:00 Page Count : 15 Creation Date : 2007:04:19 21:27:42Z Mod Date : 2007:04:19 21:27:42Z Producer : Acrobat Distiller 5.0 (Windows) Author : Administrator Metadata Date : 2007:04:19 21:27:42Z Creator : Administrator Title : Microsoft Word - NT350.docEXIF Metadata provided by EXIF.tools