Nokia Bell XS250WXAB 7368 Intelligent Services Access Manager CPE User Manual 7368 ISAM ONT XS 240W A XS 250WX A Product Guide

Nokia Shanghai Bell Co. Ltd. 7368 Intelligent Services Access Manager CPE 7368 ISAM ONT XS 240W A XS 250WX A Product Guide

Contents

Users Manual_revised0503

Download: Nokia Bell XS250WXAB 7368 Intelligent Services Access Manager CPE User Manual 7368 ISAM ONT XS 240W A XS 250WX A Product Guide
Mirror Download [FCC.gov]Nokia Bell XS250WXAB 7368 Intelligent Services Access Manager CPE User Manual 7368 ISAM ONT XS 240W A XS 250WX A Product Guide
Document ID3837000
Application IDMxT7E9zifbRrLJNQxKHGuA==
Document DescriptionUsers Manual_revised0503
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize290.57kB (3632106 bits)
Date Submitted2018-05-03 00:00:00
Date Available2018-07-19 00:00:00
Creation Date2018-04-24 13:33:44
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2018-05-02 12:03:16
Document Title7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide
Document CreatorFrameMaker 11.0.2
Document Author: Nokia

7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide
7368 Intelligent Services Access
Manager ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
Nokia — Proprietary and confidential
Use pursuant to applicable agreements
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Nokia is a registered trademark of Nokia Corporation. Other products and company
names mentioned herein may be trademarks or tradenames of their respective
owners.
The information presented is subject to change without notice. No responsibility is
assumed for inaccuracies contained herein.
© 2018 Nokia.
Contains proprietary/trade secret information which is the property of Nokia and must
not be made available to, or copied or used by anyone outside Nokia without its
written authorization. Not to be used or disclosed except in accordance with
applicable agreements.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Preface
1 Preface
This preface provides general information about the documentation set for optical
network terminals (ONTs).
1.1
Scope
This documentation set provides information about safety, features and functionality,
ordering, hardware installation and maintenance, and software installation
procedures for the current release.
1.2
Audience
This documentation set is intended for planners, administrators, operators, and
maintenance personnel involved in installing, upgrading, or maintaining the ONTs.
1.3
Required knowledge
The reader must be familiar with general telecommunications principles.
1.4
Acronyms and initialisms
The expansions and optional descriptions of most acronyms and initialisms appear
in the glossary.
1.5
Assistance and ordering phone numbers
Nokia provides global technical support through regional call centers. Phone
numbers for the regional call centers are available at the following URL:
http://support.alcatel-lucent.com.
For ordering information, contact your Nokia sales representative.
Issue: 01
3FE-48631-AAAA-TCZZA
Preface
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
1.6
Nokia quality processes
Nokia’s ONT quality practices are in compliance with TL 9000 requirements. These
requirements are documented in the Fixed Networks Quality Manual
3FQ-30146-6000-QRZZA. The quality practices adequately ensure that technical
requirements and customer end-point requirements are met. The customer or its
representatives may be allowed to perform on-site quality surveillance audits, as
agreed upon during contract negotiations
1.7
Safety information
For safety information, see the appropriate safety guidelines chapter.
1.8
Documents
Documents are available using ALED or OLCS.
Procedure 1
To download a ZIP file package of the customer documentation
Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you
are a new user and require access to this service, please contact your Nokia sales
representative.
From the Technical Content for drop-down menu, choose the product.
Click on Downloads: Electronic Delivery.
Choose Documentation from the drop-down menu and click Next.
Select the image from the drop-down menu and click Next.
Follow the on-screen directions to download the file.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 2
Preface
To access individual documents
Individual PDFs of customer documents are also accessible through the Nokia Customer Support
website.
1.9
Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you
are a new user and require access to this service, please contact your Nokia sales
representative.
From the Technical Content for drop-down menu, choose the product.
Click on Manuals and Guides to display a list of customer documents by title and part
number. You can filter this list using the Release drop-down menu.
Click on the PDF to open or save the file.
Special information
The following are examples of how special information is presented in this document.
Danger — Danger indicates that the described activity or
situation may result in serious personal injury or death; for
example, high voltage or electric shock hazards.
Warning — Warning indicates that the described activity or
situation may, or will, cause equipment damage or serious
performance problems.
Caution — Caution indicates that the described activity or
situation may, or will, cause service interruption.
Note — A note provides information that is, or may be, of
special interest.
Issue: 01
3FE-48631-AAAA-TCZZA
Preface
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
1.9.1
Procedures with options or substeps
When there are options in a procedure, they are identified by letters. When there are
required substeps in a procedure, they are identified by roman numerals.
Procedure 3
Example of options in a procedure
At step 1, you can choose option a or b. At step 2, you must do what the step indicates.
Procedure 4
This step offers two options. You must choose one of the following:
This is one option.
This is another option.
You must perform this step.
Example of required substeps in a procedure
At step 1, you must perform a series of substeps within a step. At step 2, you must do what the
step indicates.
This step has a series of substeps that you must perform to complete the step. You must
perform the following substeps:
This is the first substep.
ii
This is the second substep.
iii
This is the third substep.
You must perform this step.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
1.10
Preface
Multiple PDF document search
You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a
common term. Adobe Reader displays the results in a single display panel. The
results are grouped by PDF file, and you can expand the entry for each file.
Note — The PDF files in which you search must be in the same
folder.
Procedure 5
To search multiple PDF files for a common term
Open Adobe Acrobat Reader.
Choose Edit→Search from the Acrobat Reader main menu. The Search PDF panel appears.
Enter the search criteria.
Click on the All PDF Documents In radio button.
Select the folder in which to search using the drop-down menu.
Click on the Search button.
Acrobat Reader displays the search results. You can expand the entries for each document
by clicking on the + symbol.
Issue: 01
3FE-48631-AAAA-TCZZA
Preface
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table of contents
Preface.............................................................................................3
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.9.1
1.10
Scope ..........................................................................................................3
Audience......................................................................................................3
Required knowledge....................................................................................3
Acronyms and initialisms .............................................................................3
Assistance and ordering phone numbers ....................................................3
Nokia quality processes...............................................................................4
Safety information........................................................................................4
Documents ..................................................................................................4
Special information ......................................................................................5
Procedures with options or substeps...........................................................6
Multiple PDF document search ...................................................................7
ETSI ONT safety guidelines .........................................................17
2.1
2.1.1
2.1.2
2.2
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.2.6
2.3
2.3.1
2.3.2
2.3.3
2.4
2.5
2.5.1
2.5.1.1
2.5.2
2.5.3
2.5.4
2.6
Safety instructions .....................................................................................17
Safety instruction boxes ............................................................................17
Safety-related labels..................................................................................18
Safety standards compliance ....................................................................19
EMC, EMI, and ESD compliance...............................................................19
Equipment safety standard compliance.....................................................19
Environmental standard compliance .........................................................20
Laser product standard compliance ..........................................................20
Resistibility requirements compliance .......................................................20
Acoustic noise emission standard compliance ..........................................20
Electrical safety guidelines ........................................................................20
Power supplies ..........................................................................................21
Cabling ......................................................................................................21
Protective earth .........................................................................................21
ESD safety guidelines ...............................................................................21
Laser safety guidelines..............................................................................21
Laser classification ....................................................................................22
Laser warning labels..................................................................................22
Transmit optical output ..............................................................................24
Normal laser operation ..............................................................................24
Location class............................................................................................25
Environmental requirements......................................................................25
ETSI environmental and CRoHS guidelines...............................27
3.1
3.1.1
3.1.2
3.1.2.1
3.1.2.2
Environmental labels .................................................................................27
Overview....................................................................................................27
Environmental related labels .....................................................................27
Products below Maximum Concentration Value (MCV) label....................27
Products containing hazardous substances above Maximum
Concentration Value (MCV) label ..............................................................28
Hazardous Substances Table (HST).........................................................29
Other environmental requirements ............................................................29
3.2
3.3
Issue: 01
3FE-48631-AAAA-TCZZA
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
ONT environmental requirements .............................................................29
Storage ......................................................................................................29
Transportation ...........................................................................................30
Stationary use............................................................................................30
Thermal limitations ....................................................................................30
Material content compliance......................................................................30
End-of-life collection and treatment ...........................................................31
ANSI ONT safety guidelines ........................................................33
4.1
4.1.1
4.1.2
4.2
4.2.1
4.2.2
4.2.3
4.2.4
4.2.5
4.3
4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.4
4.4.1
4.4.2
4.4.3
4.5
4.6
Safety instructions .....................................................................................33
Safety instruction boxes in customer documentation ................................33
Safety-related labels..................................................................................34
Safety standards compliance ....................................................................35
EMC, EMI, and ESD standards compliance..............................................36
Equipment safety standard compliance.....................................................36
Environmental standards compliance........................................................37
Laser product standards compliance.........................................................37
Resistibility requirements compliance .......................................................38
Laser safety guidelines..............................................................................38
Laser warning labels..................................................................................38
Laser classification ....................................................................................40
Transmit optical output ..............................................................................41
Normal laser operation ..............................................................................41
Location class............................................................................................41
Electrical safety guidelines ........................................................................42
Power supplies ..........................................................................................42
Cabling ......................................................................................................42
Protective earth .........................................................................................42
ESD safety guidelines ...............................................................................42
Environmental requirements......................................................................43
XS-240W-A and XS-250WX-A unit data sheet ............................45
5.1
5.2
5.2.1
5.3
XS-240W-A and XS-250WX-A part numbers and identification ................45
XS-240W-A and XS-250WX-A general description...................................48
TR69 authentication using TLS and CA certificates ..................................51
XS-240W-A and XS-250WX-A software and installation feature
support.......................................................................................................52
XS-240W-A and XS-250WX-A interfaces and interface capacity..............52
XS-240W-A and XS-250WX-A connections and components ..................53
XS-240W-A and XS-250WX-A LEDs ........................................................53
XS-240W-A and XS-250WX-A detailed specifications ..............................55
XS-240W-A and XS-250WX-A GEM ports and T-CONTs.........................56
XS-240W-A and XS-250WX-A functional blocks.......................................57
XS-240W-A and XS-250WX-A standards compliance ..............................61
Responsible party......................................................................................61
Energy-related products standby and off modes compliance....................62
FCC statement ..........................................................................................62
FCC Radiation Exposure Statement .........................................................63
XS-240W-A and XS-250WX-A special considerations..............................63
Wi-Fi service..............................................................................................63
5.4
5.4.1
5.5
5.6
5.7
5.8
5.9
5.9.1
5.9.2
5.9.3
5.9.4
5.10
5.10.1
10
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Issue: 01
5.10.1.1
5.10.1.2
5.10.1.3
5.10.2
Wi-Fi physical features ..............................................................................63
Wi-Fi standards and certifications .............................................................64
Wi-Fi GUI features.....................................................................................64
XS-240W-A and XS-250WX-A ONT considerations and limitations .........64
Install an XS-240W-A or XS-250WX-A indoor ONT ....................65
6.1
6.2
6.3
6.4
6.5
6.6
Purpose .....................................................................................................65
General......................................................................................................65
Prerequisites..............................................................................................65
Recommended tools..................................................................................65
Safety information......................................................................................66
Procedure ..................................................................................................67
Replace an XS-240W-A or XS-250WX-A indoor ONT.................73
7.1
7.2
7.3
7.4
7.5
7.6
Purpose .....................................................................................................73
General......................................................................................................73
Prerequisites..............................................................................................73
Recommended tools..................................................................................73
Safety information......................................................................................74
Procedure ..................................................................................................75
Configure an XS-240W-A or XS-250WX-A indoor ONT .............79
8.1
8.2
8.2.1
8.2.2
8.2.3
8.2.4
8.2.5
8.2.6
8.2.7
General......................................................................................................79
HGU mode GUI configuration....................................................................79
Login..........................................................................................................79
Device and connection status....................................................................80
Network configuration................................................................................94
Security configuration ..............................................................................113
Application configuration .........................................................................122
Maintenance ............................................................................................130
RG troubleshooting counters...................................................................142
3FE-48631-AAAA-TCZZA
11
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
12
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
List of figures
Issue: 01
ETSI ONT safety guidelines .........................................................17
Figure 1
Figure 2
Figure 3
Figure 4
PSE certification ........................................................................................19
Laser product label ....................................................................................22
Laser classification label............................................................................23
Laser warning labels..................................................................................24
ETSI environmental and CRoHS guidelines...............................27
Figure 5
Figure 6
Figure 7
Products below MCV value label...............................................................28
Products above MCV value label ..............................................................28
Recycling/take back/disposal of product symbol .......................................31
ANSI ONT safety guidelines ........................................................33
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Sample safety label on the ONT equipment..............................................35
Sample laser product label showing CDRH 21 CFR compliance..............37
Laser product label ....................................................................................39
Laser classification label............................................................................39
Laser warning labels..................................................................................40
Sample laser product safety label on the ONT equipment ........................41
XS-240W-A and XS-250WX-A unit data sheet ............................45
Figure 14
Figure 15
Figure 16
Figure 17
Figure 18
Figure 19
Figure 20
XS-240W-A or XS-250WX-A in wall mounting bracket .............................49
XS-240W-A ONT connections...................................................................50
XS-250WX-A ONT connections ................................................................50
XS-250WX-A indoor ONT LEDs................................................................54
Functional blocks for XS-240W-A ONT .....................................................58
Functional blocks for XS-250WX-A ONT...................................................59
XS-240W-A and XS-250WX-A ONT SoC hardware block ........................60
Install an XS-240W-A or XS-250WX-A indoor ONT ....................65
Figure 21
Figure 22
Figure 23
Figure 24
XS-240W-A and XS-250WX-A wall mounting bracket ..............................68
XS-240W-A and XS-250WX-A ONT in wall mounting bracket ..................68
XS-240W-A ONT connections...................................................................69
XS-250WX-A connections .........................................................................69
Replace an XS-240W-A or XS-250WX-A indoor ONT.................73
Figure 25
Figure 26
XS-240W-A ONT connections...................................................................75
XS-250WX-A ONT connections ................................................................76
Configure an XS-240W-A or XS-250WX-A indoor ONT .............79
Figure 27
Figure 28
Figure 29
Figure 30
Figure 31
Figure 32
Figure 33
Figure 34
Figure 35
Web login window......................................................................................80
Device Information window........................................................................81
LAN status window ....................................................................................83
WAN status window...................................................................................85
WAN status IPv6 window ..........................................................................87
Home networking information window.......................................................89
Optics module status window ....................................................................90
Statistics window .......................................................................................92
Voice Information window..........................................................................93
3FE-48631-AAAA-TCZZA
13
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 36
Figure 37
Figure 38
Figure 39
Figure 40
Figure 41
Figure 42
Figure 43
Figure 44
Figure 45
Figure 46
Figure 47
Figure 48
Figure 49
Figure 50
Figure 51
Figure 52
Figure 53
Figure 54
Figure 55
Figure 56
Figure 57
Figure 58
Figure 59
Figure 60
Figure 61
Figure 62
Figure 63
Figure 64
Figure 65
Figure 66
Figure 67
Figure 68
Figure 69
14
LAN network window .................................................................................95
LAN IPv6 network window.........................................................................97
WAN network window................................................................................99
WAN DHCP window ................................................................................100
Wireless 2.4GHz network window ...........................................................102
Wireless 5GHz network window ..............................................................105
Wireless Schedule network window ........................................................107
IP Routing network window .....................................................................108
DNS network window ..............................................................................109
TR-069 network window ..........................................................................111
QoS Config window (L2)..........................................................................112
Firewall window .......................................................................................114
MAC filter window....................................................................................115
IP filter window ........................................................................................116
URL Filter window ...................................................................................118
DMZ and ALG window.............................................................................119
Access Control window ...........................................................................121
Port forwarding window ...........................................................................123
DDNS window .........................................................................................124
NTP window ............................................................................................125
USB window ............................................................................................126
UPnP and DLNA window.........................................................................128
Voice setting window ...............................................................................129
Password window....................................................................................132
LOID Config window................................................................................133
SLID configuration window ......................................................................134
Device management window...................................................................135
Backup and Restore window ...................................................................136
Firmware upgrade window ......................................................................137
Reboot window ........................................................................................138
Factory default window............................................................................139
Diagnose window ....................................................................................140
Log window..............................................................................................141
RG Troubleshooting Counters window....................................................143
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
List of tables
ETSI ONT safety guidelines .........................................................17
Table 1
Safety labels ..............................................................................................18
ANSI ONT safety guidelines ........................................................33
Table 2
Safety labels ..............................................................................................34
XS-240W-A and XS-250WX-A unit data sheet ............................45
Table 3
Table 4
Table 5
Table 6
Table 7
Identification of XS-240W-A indoor ONTs .................................................45
Identification of XS-250WX-A indoor ONTs...............................................46
XS-240W-A and XS-250WX-A power supply ............................................48
XS-240W-A and XS-250WX-A comparison...............................................48
XS-240W-A and XS-250WX-A indoor ONT interface connection
capacity .....................................................................................................52
XS-240W-A and XS-250WX-A indoor ONT physical connections ............53
XS-240W-A and XS-250WX-A indoor ONT LEDs.....................................54
XS-240W-A and XS-250WX-A indoor ONT physical specifications ..........55
XS-240W-A and XS-250WX-A indoor ONT power consumption
specifications .............................................................................................56
XS-240W-A and XS-250WX-A indoor ONT environmental
specifications .............................................................................................56
XS-240W-A and XS-250WX-A indoor ONT capacity for GEM ports
and T-CONTs ............................................................................................57
Responsible party contact information ......................................................62
XS-240W-A and XS-250WX-A ONT considerations and limitations .........64
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor ONT .............79
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Device Information parameters .................................................................81
LAN status parameters..............................................................................83
WAN status parameters ............................................................................85
WAN status IPv6 parameters ....................................................................87
Home networking parameters ...................................................................89
Optics module status parameters..............................................................91
Voice Information parameters ...................................................................93
LAN network parameters...........................................................................95
LAN IPv6 network parameters...................................................................97
WAN network parameters .........................................................................99
WAN DHCP parameters..........................................................................101
Wireless 2.4GHz network parameters.....................................................102
Wireless 5GHz network parameters........................................................105
IP Routing network parameters ...............................................................108
DNS network parameters ........................................................................110
TR-069 network parameters....................................................................111
QoS Config parameters...........................................................................113
Firewall parameters .................................................................................115
MAC filter parameters..............................................................................116
IP filter parameters ..................................................................................117
URL Filter parameters .............................................................................118
3FE-48631-AAAA-TCZZA
15
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44
Table 45
Table 46
Table 47
16
DMZ and ALG parameters ......................................................................119
Access control parameters ......................................................................121
Port forwarding parameters .....................................................................123
DDNS parameters ...................................................................................124
USB parameters ......................................................................................127
Voice setting parameters.........................................................................130
Password parameters..............................................................................132
LOID configuration parameters ...............................................................133
SLID configuration parameters................................................................134
Device management parameters ............................................................135
RG Troubleshooting Counters parameters..............................................143
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ETSI ONT safety guidelines
2 ETSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the optical network terminals (ONTs).
2.1
Safety instructions
This section describes the safety instructions that are provided in the ONT customer
documentation and on the equipment.
2.1.1
Safety instruction boxes
The safety instruction boxes are provided in the ONT customer documentation.
Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger — Possibility of personal injury.
The Danger box indicates that the described activity or situation may pose a threat
to personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
The following is an example of the Warning box.
Warning 1 — Possibility of equipment damage.
Warning 2 — Possibility of data loss.
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid the
degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
Issue: 01
3FE-48631-AAAA-TCZZA
17
ETSI ONT safety guidelines
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
The following is an example of the Caution box.
Caution 1 — Possibility of service interruption.
Caution 2 — Service interruption.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
The following is an example of the Note box.
Note — Information of special interest.
The Note box provides information that assists the personnel working with ONTs. It
does not provide safety-related instructions.
2.1.2
Safety-related labels
The ONT equipment is labeled with the specific safety instructions and compliance
information that is related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 1 provides sample safety labels on the ONT equipment.
Table 1
Safety labels
Description
Label text
ESD warning
Caution: This assembly contains an electrostatic sensitive device.
Laser classification
Class 1 laser product
PSE marking
These power supplies are Japan PSE certified and compliant with
Japan VCCI emissions standards.
Figure 1 shows the PSE certification.
18
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 1
ETSI ONT safety guidelines
PSE certification
This is a Class B product based on the standard of the Voluntary Control Council for Interference
from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in
a domestic environment, it may cause radio interference. Install and use the equipment according
to the instruction manual.
Warning
19841
2.2
Safety standards compliance
This section describes the ONT compliance with the European safety standards.
2.2.1
EMC, EMI, and ESD compliance
The ONT equipment complies with the following EMC, EMI, and ESD requirements:
• EN 300-328 v1.9.1 wide band data transmission standards for 2.4GHz bands
• EN 300-386 V1.5.1: Electromagnetic Compatibility and Radio Spectrum Matters
•
•
•
•
•
2.2.2
(ERM): Telecommunications Network Equipment; Electromagnetic Compatibility
(EMC) requirements; Electrostatic Discharge (ESD) requirements
EN 55022 (2006): Class B, Information Technology Equipment, Radio
Disturbance Characteristics, limits and methods of measurement
EN 55024 (2010): Information Technology Equipment, Immunity Characteristics,
limits and methods of measurement
European Council Directive 2004/108/EC
EN 300-386 V1.4.1: 2008
EN 55022:2006 Class B (ONTs)
Equipment safety standard compliance
The ONT equipment complies with the requirements of EN 60950-1, Safety of
Information Technology Equipment for use in a restricted location (per R-269).
Issue: 01
3FE-48631-AAAA-TCZZA
19
ETSI ONT safety guidelines
2.2.3
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Environmental standard compliance
The ONT equipment complies with the EN 300 019 European environmental
standards.
2.2.4
Laser product standard compliance
For most ONTs, the ONT equipment complies with EN 60825-1 and IEC 60825-2 for
laser products. If there is an exception to this compliance regulation, you can find this
information in the standards compliance section of the unit data sheet in this Product
Guide.
2.2.5
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU Recommendation K.21
for resistibility of telecommunication equipment installed in customer premises to
over voltage and overcurrents.
2.2.6
Acoustic noise emission standard compliance
The ONT equipment complies with EN 300 753 acoustic noise emission limit and test
methods.
2.3
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note 1 — The ONTs comply with the U.S. National Electrical
Code. However, local electrical authorities have jurisdiction
when there are differences between the local and U.S.
standards.
Note 2 — The ONTs comply with BS EN 61140.
20
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
2.3.1
ETSI ONT safety guidelines
Power supplies
The use of any non-Nokia approved power supplies or power adapters is not
supported or endorsed by Nokia. Such use will void any warranty or support contract
with Nokia. Such use greatly increases the danger of damage to equipment or
property.
2.3.2
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• All cables must be approved by the relevant national electrical code.
• The cables for outdoor installation of ONTs must be suitable for outdoor use.
• POTS wiring run outside the subscriber premises must comply with the
requirements of local electrical codes. In some markets, the maximum allowed
length of the outside run is 140 feet (43 m). If the outside run is longer, NEC
requires primary protection at both the exit and entry points for the wire.
2.3.3
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of local
electrical codes.
2.4
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This equipment is ESD sensitive. Proper ESD
protections should be used when you enter the TELCO Access
portion of the ONT.
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
2.5
Laser safety guidelines
Observe the following instructions when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Issue: 01
3FE-48631-AAAA-TCZZA
21
ETSI ONT safety guidelines
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Danger — There may be invisible laser radiation at the fiber
optic cable when the cable is removed from the connector.
Avoid direct exposure to the laser beam.
Observe the following danger for laser hazard. Eyes can be damaged when they are
exposed to a laser beam. Take necessary precautions before you plug in the optical
modules.
Danger — Possibility of equipment damage. Risk of eye
damage by laser radiation.
2.5.1
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
2.5.1.1
Laser warning labels
The following figures show the labels related to laser product, classification and
warning.
Figure 2 shows a laser product label.
Figure 2
Laser product label
18455
Figure 3 shows a laser classification label. Laser classification labels may be
provided in other languages.
22
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 3
ETSI ONT safety guidelines
Laser classification label
CLASS 1 LASER PRODUCT
PRODUCTO LASER
CLASE 1
CLASE
1 DEL LASER
LASER CLASSE 1
18992
Figure 4 shows a laser warning label and an explanatory label for laser products.
Labels and warning may be provided in other languages. The explanatory label
provides the following information:
• a warning that calls attention to the invisible laser radiation
• an instruction against staring into the beam or viewing directly with optical
instruments
• wavelength
• normal output power
• maximum output power
Issue: 01
3FE-48631-AAAA-TCZZA
23
ETSI ONT safety guidelines
Figure 4
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Laser warning labels
INVISIBLE LASER RADIATION
DO NOT STARE INTO BEAM
OR VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Wavelength(s): xxxx nm
Normal output power: xx m W
Max output power: yyy m W
Laser Warning Label
Laser Warning Label
CLASS 1 LASER PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE
EVITER TOUTE EXPOSITION AU FAISCEAU
NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE
CLASE 1 DEL LASER
RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.
Laser Warning Label
18993
2.5.2
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
2.5.3
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Eyes can be damaged when they exposed to a laser beam. Operating personnel
must observe the instructions on the laser explanatory label before plugging in the
optical module.
Danger — Risk of eye damage by laser radiation.
24
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
2.5.4
ETSI ONT safety guidelines
Location class
Use cable supports and guides to protect the receptacles from strain.
2.6
Environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid condensation caused by rapid changes
in temperature and humidity, Nokia recommends:
• The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
• If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
• When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Issue: 01
3FE-48631-AAAA-TCZZA
25
ETSI ONT safety guidelines
26
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ETSI environmental and CRoHS guidelines
3 ETSI environmental and CRoHS
guidelines
This chapter provides information about the ETSI environmental China Restriction of
Hazardous Substances (CRoHS) regulations that govern the installation and
operation of the optical line termination (OLT) and optical network termination (ONT)
systems. This chapter also includes environmental operation parameters of general
interest.
3.1
Environmental labels
This section describes the environmental instructions that are provided with the
customer documentation, equipment, and location where the equipment resides.
3.1.1
Overview
CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold
and imported in the territory of the mainland of the People’s Republic of China. EIP
refers to products and their accessories manufactured by using electronic
information technology, including electronic communications products and such
subcomponents as batteries and cables.
3.1.2
Environmental related labels
Environmental labels are located on appropriate equipment. The following are
sample labels.
3.1.2.1
Products below Maximum Concentration Value
(MCV) label
Figure 5 shows the label that indicates a product is below the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). Products with this label are recyclable. The label may be found in this
documentation or on the product.
Issue: 01
3FE-48631-AAAA-TCZZA
27
ETSI environmental and CRoHS guidelines
Figure 5
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Products below MCV value label
18986
3.1.2.2
Products containing hazardous substances above
Maximum Concentration Value (MCV) label
Figure 6 shows the label that indicates a product is above the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). The number contained inside the label indicates the Environment-Friendly
User Period (EFUP) value. The label may be found in this documentation or on the
product.
Figure 6
28
Products above MCV value label
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ETSI environmental and CRoHS guidelines
Together with major international telecommunications equipment companies, Nokia
has determined it is appropriate to use an EFUP of 50 years for network
infrastructure equipment and an EFUP of 20 years for handsets and accessories.
These values are based on manufacturers' extensive practical experience of the
design, manufacturing, maintenance, usage conditions, operating environments,
and physical condition of infrastructure and handsets after years of service. The
values reflect minimum values and refer to products operated according to the
intended use conditions. See “Hazardous Substances Table (HST)” for more
information.
3.2
Hazardous Substances Table (HST)
This section describes the compliance of the OLT and ONT equipment to the CRoHS
standard when the product and subassemblies contain hazardous substances
beyond the MCV value. This information is found in this user documentation where
part numbers for the product and subassemblies are listed. It may be referenced in
other OLT and ONT documentation.
In accordance with the People’s Republic of China Electronic Industry Standard
Marking for the Control of Pollution Caused by Electronic Information Products
(SJ/T11364-2006), customers may access the Nokia Hazardous Substance Table,
in Chinese, from the following location:
• http://www.nokia-sbell.com/wwwroot/images/upload/private/1/media/ChinaRoHS.p
df
3.3
Other environmental requirements
Observe the following environmental requirements when handling the P-OLT or ONT
equipment.
3.3.1
ONT environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
3.3.2
Storage
According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in
Class 1.1, weather-protected, temperature-controlled locations.
Issue: 01
3FE-48631-AAAA-TCZZA
29
ETSI environmental and CRoHS guidelines
3.3.3
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of the OLT equipment must
be in packed, public transportation with no rain on packing allowed.
3.3.4
Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment
must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.
3.3.5
Thermal limitations
When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The
thermal limitations for OLT operation in a CO or CEV are:
•
•
•
•
3.3.6
operating temperature: 5°C to 40°C (41°F to 104°F)
short-term temperature: –5°C to 50°C (23°F to 122°F)
operating relative humidity: 5% to 85%
short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg
Material content compliance
European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain
Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium,
hexavalent chromium, and certain flame retardants in electrical and electronic
equipment. This Directive applies to electrical and electronic products placed on the
EU market after 1 July 2006, with various exemptions, including an exemption for
lead solder in network infrastructure equipment. Nokia products shipped to the EU
after 1 July 2006 comply with the EU RoHS Directive.
Nokia has implemented a material/substance content management process. The
process is described in: Nokia process for ensuring RoHS Compliance
(1AA002660031ASZZA). This ensures compliance with the European Union
Directive 2011/65/EU on the Restriction of the Use of Certain Hazardous Substances
in Electrical and Electronic Equipment (RoHS2). With the process equipment is
assessed in accordance with the Harmonised Standard EN50581:2012 (CENELEC)
on Technical documentation for the assessment of electrical and electronic products
with respect to the restriction of hazardous substances.
30
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3.3.7
ETSI environmental and CRoHS guidelines
End-of-life collection and treatment
Electronic products bearing or referencing the symbol shown in Figure 7, when put
on the market within the European Union (EU), shall be collected and treated at the
end of their useful life, in compliance with applicable EU and local legislation. They
shall not be disposed of as part of unsorted municipal waste. Due to materials that
may be contained in the product, such as heavy metals or batteries, the environment
and human health may be negatively impacted as a result of inappropriate disposal.
Note — In the European Union, a solid bar under the symbol for
a crossed-out wheeled bin indicates that the product was put on
the market after 13 August 2005.
Figure 7
Recycling/take back/disposal of product symbol
At the end of their life, the OLT and ONT products are subject to the applicable local
legislations that implement the European Directive 2012/19EU on waste electrical
and electronic equipment (WEEE).
There can be different requirements for collection and treatment in different member
states of the European Union.
In compliance with legal requirements and contractual agreements, where
applicable, Nokia will offer to provide for the collection and treatment of Nokia
products bearing the logo shown in Figure 7 at the end of their useful life, or products
displaced by Nokia equipment offers. For information regarding take-back of
equipment by Nokia, or for more information regarding the requirements for
recycling/disposal of product, contact your Nokia account manager or Nokia take
back support at sustainability.global@nokia.com.
Issue: 01
3FE-48631-AAAA-TCZZA
31
ETSI environmental and CRoHS guidelines
32
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ANSI ONT safety guidelines
4 ANSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the optical network terminals or units (ONTs or ONUs)
in the North American or ANSI market.
4.1
Safety instructions
This section describes the safety instructions that are provided in the ONT customer
documentation and on the equipment.
4.1.1
Safety instruction boxes in customer
documentation
The safety instruction boxes are provided in the ONT customer documentation.
Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger — Possibility of personal injury.
The Danger box indicates that the described activity or situation may pose a threat
to personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
The following is an example of the Warning box.
Warning 1 — Possibility of equipment damage.
Warning 2 — Possibility of data loss.
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid the
degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
Issue: 01
3FE-48631-AAAA-TCZZA
33
ANSI ONT safety guidelines
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
The following is an example of the Caution box.
Caution 1 — Possibility of service interruption.
Caution 2 — Service interruption.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
The following is an example of the Note box.
Note — Information of special interest.
The Note box provides information that assists the personnel working with ONTs. It
does not provide safety-related instructions.
4.1.2
Safety-related labels
The ONT equipment is labeled with specific safety compliance information and
instructions that are related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 2 provides examples of the text in the various ONT safety labels.
Table 2
Safety labels
Description
Label text
UL compliance
Communication service equipment US listed. Type 3R enclosure Rainproof.
TUV compliance
Type 3R enclosure - Rainproof.
ESD warning
Caution: This assembly contains electrostatic sensitive device.
Laser classification
Class 1 laser product
Laser product compliance
This laser product conforms to all applicable standards of 21 CFR
1040.10 at date of manufacture.
FCC standards compliance
Tested to comply with FCC standards for home or office use.
CDRH compliance
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007
(1 of 2)
34
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ANSI ONT safety guidelines
Description
Label text
Operation conditions
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Canadian standard
compliance (modular ONT)
This Class A digital apparatus complies with Canadian ICES-003.
Canadian standard
compliance (outdoor ONT)
This Class B digital apparatus complies with Canadian ICES-003.
CE marking
There are various CE symbols for CE compliance.
(2 of 2)
Figure 8 shows a sample safety label on the ONT equipment.
Figure 8
Sample safety label on the ONT equipment
Tested to Comply
with FCC Standards
FOR HOME OR OFFICE USE
®
COMMUNICATION SERVICE EQUIPMENT
US LISTED
27FY
Type 3R Enclosure - Rainproof
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil
numerique de la class A est conforme a la norme NMB-003 du Canada
CAUTION
This Assembly Contains Electrostatic Sensitive Devices
18533
4.2
Safety standards compliance
This section describes the ONT compliance with North American safety standards.
Warning — Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Issue: 01
3FE-48631-AAAA-TCZZA
35
ANSI ONT safety guidelines
4.2.1
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
EMC, EMI, and ESD standards compliance
The ONT equipment complies with the following requirements:
• Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class
A requirements for OLT equipment
• GR-1089-CORE requirements, including:
• Section 3 Electromagnetic Interference, Emissions Radiated and Conducted
• Section 3 Immunity, Radiated and Conducted
• Section 2 ESD Discharge Immunity: System Level Electrostatic Discharge and EFT
Immunity: Electrically Fast Transients
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is needed.
• Consult the dealer or an experienced radio/TV technician for help.
4.2.2
Equipment safety standard compliance
The ONT equipment complies with the requirements of UL60950-1, Outdoor ONTs
to “Communication Service Equipment” (CSE) and Indoor ONTs to Information
Technology Equipment (ITE).
36
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
4.2.3
ANSI ONT safety guidelines
Environmental standards compliance
The ONT equipment complies with the following standards:
• GR-63-CORE (NEBS): requirements related to operating, storage, humidity,
altitude, earthquake, office vibration, transportation and handling, fire resistance
and spread, airborne contaminants, illumination, and acoustic noise
GR-487-CORE: requirements related to rain, chemical, sand, and dust
GR-487 R3-82: requirements related to condensation
GR-3108: Requirements for Network Equipment in the Outside Plant (OSP)
TP76200: Common Systems Equipment Interconnections Standards
•
•
•
•
4.2.4
Laser product standards compliance
The ONT equipment complies with 21 CFR 1040.10 and CFR 1040.11, except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007” or to 21 CFR
1040.10 U.S. Center for Devices and Radiological Health (CDRH) of the Food and
Drug Administration (FDA) Laser Notice 42 for ONTs containing Class 1 Laser
modules certified by original manufactures.
Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such
as Nokia ONTs shall leave the following Laser Safety cautions with the end user.
a) “Class 1 Laser Product”
b) “Caution – Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.”
Figure 9 shows a laser product label.
Figure 9
Sample laser product label showing CDRH 21 CFR compliance
4P92
No User Serviceable Parts Inside. Refer All Servicing To Qualified Personnel.
12VDC
2.5A
FiOS Enabled
I.T.E
To Order FiOS: 888 GET-FiOS
Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to 2301 Sugar Bush Rd. or visit Verizon.com
For Service: 888 553-1555
Laser Notice No. 50, dated June 24, 2007. Raleigh, NC 27612
22813
Issue: 01
3FE-48631-AAAA-TCZZA
37
ANSI ONT safety guidelines
4.2.5
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU Recommendation K.21
for resistibility of telecommunication equipment installed in customer premises to
overvoltage and overcurrents.
4.3
Laser safety guidelines
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Observe the following warnings when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Danger — There may be invisible laser radiation at the fiber
optic cable when the cable is removed from the connector.
Avoid direct exposure to beam.
Observe the following danger for a laser hazard. Eyes can be damaged when they
are exposed to a laser beam. Take necessary precautions before you plug in the
optical modules.
Danger — Possibility of equipment damage. Risk of eye
damage by laser radiation.
Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such
as Nokia ONTs shall leave the following Laser Safety cautions with the end user.
a) “Class 1 Laser Product”
b) “Caution – Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation exposure.”
4.3.1
Laser warning labels
The following figures show sample labels related to laser product, classification and
warning.
Figure 10 shows a laser product label.
38
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 10
ANSI ONT safety guidelines
Laser product label
18455
Figure 11 shows a laser classification label. Laser classification labels may be
provided in other languages.
Figure 11
Laser classification label
CLASS 1 LASER PRODUCT
PRODUCTO LASER
CLASE 1
CLASE
1 DEL LASER
LASER CLASSE 1
18992
Figure 12 shows a laser warning label and an explanatory label for laser products.
Explanatory labels may be provided in other languages. The explanatory label
provides the following information:
• a warning that calls attention to the invisible laser radiation
• an instruction against staring into the beam or viewing directly with optical
instruments
• wavelength
• normal output power
• maximum output power
Issue: 01
3FE-48631-AAAA-TCZZA
39
ANSI ONT safety guidelines
Figure 12
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Laser warning labels
INVISIBLE LASER RADIATION
DO NOT STARE INTO BEAM
OR VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Wavelength(s): xxxx nm
Normal output power: xx m W
Max output power: yyy m W
Laser Warning Label
Laser Warning Label
CLASS 1 LASER PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE
EVITER TOUTE EXPOSITION AU FAISCEAU
NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE
CLASE 1 DEL LASER
RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.
Laser Warning Label
18993
4.3.2
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
For Class 1 laser products, lasers are safe under reasonably foreseeable conditions
of operation, including the use of optical instruments for intrabeam viewing.
Figure 13 shows a sample laser product safety label on the ONT equipment.
40
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 13
ANSI ONT safety guidelines
Sample laser product safety label on the ONT equipment
Model:
MFG:
MONTH: XX
YEAR: XXXX
ICS: XX
MRev: XX
3FE55851ABAA
MAC:XXXXXXXXXXXX
SN:ALCLXXXXXXXX
I.T.E
FCC ID: XXXXXXXXXXX
12VDC
3A
ASSEMBLED IN CHINA
2301 Sugar Bush Rd.
Raleigh, NC 27612
CLASS 1 LASER PRODUCT
PRODUIT LASER DE CLASSE 1
Intertek
4006119
This device complies with Part 15 of the FCC Rule.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received,
including intereference that may cause undesired operation.
DANGER - Invisible Laser radiation when open.
AVOID DIRECT EXPOSURE TO BEAM.
DANGER - Rayonnement Laser invisible lorsqu’elle
est ouverte. Evitee l’expostion direct au faisceau.
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to Laser Notice No. 50 dated June 24, 2007
18532
4.3.3
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
4.3.4
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Operating personnel must observe the instructions on the laser explanatory label
before plugging in the optical module.
Danger — Risk of eye damage by laser radiation.
4.3.5
Location class
Use cable supports and guides to protect the receptacles from strain.
Issue: 01
3FE-48631-AAAA-TCZZA
41
ANSI ONT safety guidelines
4.4
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note — The ONTs comply with the U.S. National Electrical
Code. However, local electrical authorities have jurisdiction
when there are differences between the local and U.S.
standards.
4.4.1
Power supplies
The use of any non-Nokia approved power supplies or power adapters is not
supported or endorsed by Nokia. Such use will void any warranty or support contract
with Nokia. Such use greatly increases the danger of damage to equipment or
property.
4.4.2
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• Use only cables approved by the relevant national electrical code.
• Use cables suitable for outdoor use for outdoor installation of ONTs.
• The ONTs have been evaluated for use with external POTS wiring without primary
protection that may not exceed 140 ft (43 m) in reach. However, the power cable
must not exceed 100 ft (31 m).
4.4.3
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of NEC article
250 or local electrical codes.
4.5
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This equipment is ESD sensitive. Proper ESD
protections should be used when entering the TELCO Access
portion of the ONT.
42
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
ANSI ONT safety guidelines
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Nokia recommends that you prepare the site before you install the ONT equipment.
In addition, you must control relative humidity, use static dissipating material for
furniture or flooring, and restrict the use of air conditioning.
4.6
Environmental requirements
See the ONT technical specification documentation for temperature ranges for
ONTs.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid condensation caused by rapid changes
in temperature and humidity, Nokia recommends:
• The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
• If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
• When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Issue: 01
3FE-48631-AAAA-TCZZA
43
ANSI ONT safety guidelines
44
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
5 XS-240W-A and XS-250WX-A unit
data sheet
5.1 XS-240W-A and XS-250WX-A part numbers and identification
5.2 XS-240W-A and XS-250WX-A general description
5.3 XS-240W-A and XS-250WX-A software and installation feature support
5.4 XS-240W-A and XS-250WX-A interfaces and interface capacity
5.5 XS-240W-A and XS-250WX-A LEDs
5.6 XS-240W-A and XS-250WX-A detailed specifications
5.7 XS-240W-A and XS-250WX-A GEM ports and T-CONTs
5.8 XS-240W-A and XS-250WX-A functional blocks
5.9 XS-240W-A and XS-250WX-A standards compliance
5.10 XS-240W-A and XS-250WX-A special considerations
5.1
XS-240W-A and XS-250WX-A part numbers
and identification
Table 3 provides part numbers and identification information for the XS-240W-A
indoor ONT.
Table 3
Identification of XS-240W-A indoor ONTs
Ordering kit
part number (1)
Provisioning
number
Description
CLEI
CPR
ECI/
Bar
code
3FE 48631 AA
3FE 48631 AA
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac
4x4 WiFi radio with on/off switch.
—
—
—
ONT only
North American
Region (NAR)
This ONT also has 2 USB 3.0 ports.
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
45
XS-240W-A and XS-250WX-A unit data sheet
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Ordering kit
part number (1)
Provisioning
number
Description
CLEI
CPR
ECI/
Bar
code
3FE 48631 AC
3FE 48631 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac
4x4 WiFi radio with on/off switch.
—
—
—
—
—
—
—
—
—
—
—
—
ONT only
Europe, the
Middle East, and
Africa region
(EMEA)
3FE 48626 AA
This ONT also has 2 USB 3.0 ports.
3FE 48631 AA
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac
4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin US power adapter.
Also includes the power supply described in Table 5 and the
wall mounting bracket (3FE 46917 AA) shown in Figure 14.
3FE 48626 BA
3FE 48631 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac
4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin EU (European) power adapter.
Also includes the power supply described in Table 5 and the
wall mounting bracket (3FE 46917 AA) shown in Figure 14.
3FE 48626 CA
3FE 48631 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac
4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin UK (British) power adapter.
Also includes the power supply described in Table 5 and the
wall mounting bracket (3FE 46917 AA) shown in Figure 14.
(2 of 2)
Notes
(1)
These kits will be available in a future release.
Table 4 provides part numbers and identification information for the XS-250WX-A
indoor ONT.
Table 4
Identification of XS-250WX-A indoor ONTs
Ordering kit
part number (1)
Provisioning
number
Description
CLEI
CPR
ECI/
Bar
code
3FE 48307 AA
3FE 48307 AA
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n
3x3 and 802.11ac 4x4 WiFi radio with on/off switch.
—
—
—
ONT only
North American
Region (NAR)
This ONT also has 2 USB 3.0 ports.
(1 of 2)
46
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
Ordering kit
part number (1)
Provisioning
number
Description
CLEI
CPR
ECI/
Bar
code
3FE 48307 AC
3FE 48307 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n
3x3 and 802.11ac 4x4 WiFi radio with on/off switch.
—
—
—
—
—
—
—
—
—
—
—
—
ONT only
Europe, the
Middle East, and
Africa region
(EMEA)
3FE 48439 AA
This ONT also has 2 USB 3.0 ports.
3FE 48307 AA
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n
3x3 and 802.11ac 4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin US power adapter.
Also includes the power supply described in Table 5.
3FE 48439 BA
3FE 48307 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n
3x3 and 802.11ac 4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin EU (European) power adapter.
Also includes the power supply described in Table 5.
3FE 48439 CA
3FE 48307 AC
XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T
Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n
3x3 and 802.11ac 4x4 WiFi radio with on/off switch.
This ONT also has 2 USB 3.0 ports.
Includes a 3-pin UK (British) power adapter.
Also includes the power supply described in Table 5.
(2 of 2)
Notes
(1)
These kits will be available in Release 5.7.01.
Table 5 provides power supply ordering information about the XS-240W-A and
XS-250WX-A ONT. For more information on power supplies, see the 7368 ISAM
ONT Power Supply and UPS Guide.
Issue: 01
3FE-48631-AAAA-TCZZA
47
XS-240W-A and XS-250WX-A unit data sheet
Table 5
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A power supply
Power/UPS model
Power UPS and cabling part number
information
Customer
category or
country
compliance tested
for (1)
Notes
Delta power adapter,
ADP-66CR BC
Part number: 1AF29813 AA
AC/DC 12V, 66W, 5.5A power,
6-pin Molex DC connector
(AC power cable not included)
•
ANSI municipality
United States,
Canada
AC cable variants:
•
•
•
•
1AB076760010 (UK, Ireland,
Middle East)
1AB076760071 (Europe)
1AB076760009 (Australia, New
Zealand, and China)
1AB076760072 (UK, South Africa,
and Middle East)
1AB076760073 (ANSI)
Common European
Union countries
Note
(1)
The list of detailed tests (for example, GR-1089i3 (ESD, EFT, RDE, CDE, RDI, and CDI), GR-1089i4 (LightningAC) and marks (for example,
FCC Class B, UL, CE Mark Class B, and K.21) are available from your Nokia technical support representative.
Table 6 provides a summary of the similarities and differences between the
XS-240W-A and the XS-250WX-A ONTs and their variants.
Table 6
XS-240W-A and XS-250WX-A comparison
Feature
XS-240W-A
XS-250WX-A
PON uplink
XGSPON
XGSPON
10G UNI port
N/A
1 x 10G UNI port
Optics
Integrated XGSPON optics on board
Integrated XGSPON optics on board
LEDs
No 10G LED
All LEDs
ANSI (NAR) variant
•
•
•
•
ETSI (EMEA) variant
5.2
ETL/FCC with DFS / WiFi Alliance
EC/WiFi Alliance
ETL/FCC with DFS / WiFi Alliance
EC/WiFi Alliance
XS-240W-A and XS-250WX-A general
description
XS-240W-A and XS-250WX-A ONTs are designed to cater to business and
residential customer requirements. These ONTs offer data and video services to the
subscriber.
48
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
XS-240W-A and XS-250WX-A indoor ONTs provide the subscriber interface for the
network by terminating the PON interface and converting it to user interfaces that
directly connect to subscriber devices. The ONT is compatible with all existing
subscriber equipment, including analog phones with both tone and rotary dial
capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I,
Type II, and Type III).
XS-240W-A and XS-250WX-A ONTs feature an XGSPON link. The XS-250WX-A
also provides one 10GE UNI port. Both ONTs provide two POTS ports and four
Ethernet interfaces.
The ONTs also feature a UPS power supply connection, on/off and reset buttons,
and two USB 3.0 ports.
On/off buttons are included for WPS, LEDs, and WLAN.
XS-240W-A and XS-250WX-A ONTs can be placed on a flat surface, such as a desk
or shelf, or in the stand provided with the ONT kit. They can also be wall mounted
using the mounting bracket (3FE 46917 AA), as shown in Figure 14.
Figure 14
XS-240W-A or XS-250WX-A in wall mounting bracket
28188
Figure 15 shows the connection for the XS-240W-A ONT.
Issue: 01
3FE-48631-AAAA-TCZZA
49
XS-240W-A and XS-250WX-A unit data sheet
Figure 15
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A ONT connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
USB 3.0 UPS power
(2)
supply
Ethernet
RJ-45 (4)
28054
Figure 16 shows the connection for the XS-250WX-A ONT.
Figure 16
XS-250WX-A ONT connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
LAN 10G
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
Ethernet
RJ-45 (4)
10 G
USB 3.0 UPS power
connection
(2)
supply
28051
XS-240W-A and XS-250WX-A indoor ONTs provide the following functions:
• 10 Gbps interface supports 100M/1G/2.5G/5G/10Gbps auto negotiation
•
•
•
•
•
•
•
•
•
•
•
50
(XS-250WX-A only)
Four RJ-45 10/100/1000 Ethernet port with auto negotiation and MDI/MDIX auto
sensing
Two POTS ports for carrier grade voice services
Two USB 3.0 ports, accessible to all LAN devices
Triple-Play services, including voice, video and high speed Internet access
Traffic classification and QoS capability
Support for fax services
Built-in layer 2 switch; Line Rate L2 traffic
512M RAM and 256M Flash
IP video distribution
Optics that support received signal strength indication (RSSI)
Concurrent 802.11n 3x3 MIMO in 2.4GHz and 802.11ac 4x4 MIMO in 5GHz
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5.2.1
XS-240W-A and XS-250WX-A unit data sheet
WLAN on/off push button
WPS on/off button
64/128 WEP encryption
WPA, WPA-PSK/TKIP
WPA2, WPA2-PSK/AES
VLAN tagging/detagging and marking/remarking of IEEE 802.1p per Ethernet
port.
Dying gasp support
SIP voice support
Multiple voice Code
DTMF dialing
Echo cancellation (G.168)
Fax mode configuration (T.30/T.38)
Caller ID, call waiting, call hold, 3-way calling, call transfer, message waiting
Forward Error Correction (FEC)
Frame Check Sequence (FCS) error counter
support for multiple SSIDs (private and public instances); contact your Nokia
representative for further details.
Routed mode per LAN port
Ethernet-based Point-to-Point (PPPoE)
DHCP client/server
DNS server/client
DDNS
Port forwarding
Network Address Translation (NAT)
Network Address Port Translation (NAPT)
UPnP IGD2.0 support
ALG
DMZ
IGMP snooping and proxy (v2/v3)
Traffic classification and QoS capability
OMCI, TR-069, and Web GUI management support
Performance monitoring and alarm reporting
Remote software image downloading and activation
IP/MAC/URL filter
Multi-level firewall and ACL
TR69 authentication using TLS and CA certificates
XS-240W-A and XS-250WX-A ONTs support TLS, as well as ACS authentication
using SHA-256 pre-installed certificates.
Issue: 01
3FE-48631-AAAA-TCZZA
51
XS-240W-A and XS-250WX-A unit data sheet
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
If the URL is set to the https://... format, by default, the connection will use TLS
without authentication mode. The ONT can also authenticate the ACS using a
pre-installed CA certificate.
5.3
XS-240W-A and XS-250WX-A software and
installation feature support
For information on installing or replacing the XS-240W-A and XS-250WX-A see:
• Install an XS-240W-A or XS-250WX-A indoor ONT
• Replace an XS-240W-A or XS-250WX-A indoor ONT
For information on the following topics, see the 7368 ISAM ONT Product Overview
Guide:
•
•
•
•
•
•
•
•
ONT and MDU general descriptions of features and functions
Ethernet interface specifications
POTS interface specifications
RSSI specifications
Wi-Fi specifications
ONT optical budget
SLID entry via Ethernet port
ONT management using an ONT interface
5.4
XS-240W-A and XS-250WX-A interfaces and
interface capacity
Table 7 describes the supported interfaces and interface capacity for XS-240W-A
and XS-250WX-A indoor ONTs.
Table 7
XS-240W-A and XS-250WX-A indoor ONT interface connection
capacity
ONT type and
model
Maximum capacity
POTS
10/ 100/ 1000
BASE-T
RF video
(CATV)
MoCA
10G UNI port
GPON SC/APC
XS-240W-A(1)
—
—
—
XS-250WX-A (1)
—
—
Note
(1)
52
The XS-240W-A and XS-250WX-A ONTs provide Wi-Fi service that is enabled and disabled using a Wi-Fi
on/off switch.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
5.4.1
XS-240W-A and XS-250WX-A unit data sheet
XS-240W-A and XS-250WX-A connections and
components
Figures 15 and 16 show the physical connections for XS-240W-A and XS-250WX-A
indoor ONTs,
Table 8 describes the physical connections for XS-240W-A and XS-250WX-A indoor
ONTs.
Table 8
XS-240W-A and XS-250WX-A indoor ONT physical connections
Connection (1)
Description
On/Off button
This button turns the ONT on or off.
WPS button
The Wi-Fi Protected Setup button enables WPS2.4G and WPS5G. This button
enables and disables WLAN data encryption.
LED button
This button turns the LEDs on or off.
WLAN button
Wi-Fi service is compliant with IEEE 802.11 standards and is enabled and disabled
using the WLAN button.
Reset button
Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the
Reset button for 10 seconds resets the ONT to the factory defaults.
POTS ports
This connection is provided through RJ-11 ports. Up to two POTS connections are
supported.The POTS ports support voice services.
Ethernet ports
This connection is provided through Ethernet RJ-45 connectors. Up to four
10/100/1000 Base-T Ethernet interfaces are supported.The Ethernet ports can
support both data and in-band video services on all four interfaces.
10GE port
The 10GE link is provided through an APC optical connector. One 10GE connection
is supported.
(XS-250WX-A only)
USB ports
This connection is provided through 2 USB 3.0 ports. The ONT supports external USB
hard drives that can be made accessible to all LAN devices.
The following rates apply to the USB 3.0 ports:
Rate current: 900mA
Maximum continuous current: 1.5A
Typical short-circuit current: 2.3A
•
•
•
UPS power supply
This connection supports the UPS power adapter described in Table 5.
Note
(1)
5.5
The primary path for the earth ground for these ONTs is provided by the 12V Return signal in the power
connector.
XS-240W-A and XS-250WX-A LEDs
Figure 17 shows the XS-250WX-A indoor ONT LEDs.
Issue: 01
3FE-48631-AAAA-TCZZA
53
XS-240W-A and XS-250WX-A unit data sheet
Figure 17
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-250WX-A indoor ONT LEDs
Power
PON Authorization
Battery
POWER
BATTERY
Link
PON
LINK
POTS
(2)
Internet
AUTH
INTERNET
TEL 1
TEL 2
5G
Wireless
WPS
VOIP
VOIP
WPS
2.4G
10G link
Ethernet (4)
2.4G
Wireless
5G
LAN 1
LAN 2
LAN 3
LAN 4
LAN 10G
28052
Note — The XS-240W-A model does not feature a 10G UNI
port and therefore does not have a LED for a 10G link.
Table 9 provides LED descriptions for XS-240W-A and XS-250WX-A indoor ONTs.
Table 9
XS-240W-A and XS-250WX-A indoor ONT LEDs
Indicator
LED color and
behavior
LED behavior description
Power
Green solid
Power on
Off
Power off
Green solid
Device is operating on AC power
Red
Device is operating on battery power
Off
Battery alarm
Battery
PON
Link
Auth
Green solid
GPON link between ONT and OLT is operating normally
Green flashing
Device is attempting to link
Off
GPON link is down or no link connected
Green solid
Link between the device and the OLT is operating normally
Off
Link is down or not connected
Green solid
ONT is authorized
Green flashing
ONT is process of ranging or synchronizing on OMCI
Off
ONT is not authorized
(1 of 2)
54
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
Indicator
LED color and
behavior
LED behavior description
INTERNET
Green solid
HSI WAN is connected: a) the device has an IP address assigned from IPCP, DHCP, or static,
and no traffic has been detected; b) the session is dropped due to idle timeout but the PON
link is still present.
Green flashing
TEL 1 to 2
VOIP
PPPoE or DHCP connection in progress
Off
HSI WAN is not connected: a) there is no physical interface connection; b) the device is in
bridged mode without an assigned IP address; c) the session has been dropped for reasons
other than idle timeout.
Green solid
Phone is off hook
Green flashing
Phone is in ‘call in’ or ‘talking’ condition
Off
Phone is on hook
Green solid
VOIP service is built up and can provide service
Off
VOIP service is not built up or out of service
WPS
Green solid
WiFi protected setup link is up (negotiation and auto-configuration successful)
2.4G and 5G
Green flashing
WiFi protected setup link activity (negotiation and auto-configuration ongoing)
Off
WiFi protected setup link down or no link connected (negotiation has not started or has failed)
Green solid
WLAN link is enabled
Green flashing
Traffic is passing via WLAN link
Off
WLAN link is disabled
Green solid
WLAN link is enabled
Green flashing
Traffic is passing via WLAN link
Off
WLAN link is disabled
Green solid
Ethernet is linked
Green flashing
LAN activity is present (in either direction)
Off
ONT power is off or Ethernet is not connected
10G
Green solid
10G link is operating normally
(XS-250WX-A
only)
Green flashing
10G link activity is present (in either direction)
Off
10G link is not connected
WLAN 2.4G
WLAN 5G
LAN 1 to 4
(2 of 2)
5.6
XS-240W-A and XS-250WX-A detailed
specifications
Table 10 lists the physical specifications for XS-240W-A and XS-250WX-A indoor
ONTs.
Table 10
XS-240W-A and XS-250WX-A indoor ONT physical specifications
Description
Specification
Length
11.4 in. (290.3 mm)
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
55
XS-240W-A and XS-250WX-A unit data sheet
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Description
Specification
Width
7.5 in. (190.3 mm)
Height
3.0 in. (76.6 mm)
Weight [within ± 0.5 lb (0.23 kg)]
2.7 lb (1.24 kg)
(2 of 2)
Table 11 lists the power consumption specifications for XS-240W-A and
XS-250WX-A indoor ONT.
Table 11
XS-240W-A and XS-250WX-A indoor ONT power consumption
specifications
Mnemonic
Maximum
power (Not to
exceed)
Condition
Minimum
power
Condition
XS-240W-A
43 W
7.62 W
XS-250WX-A
46 W
2 POTS off-hook, 4
10/100/1000 Base-T
Ethernet, Wi-Fi operational
2 POTS on-hook, other
interfaces/services not
provisioned
10.4 W
Table 12 lists the environmental specifications for XS-240W-A and XS-250WX-A
indoor ONT.
Table 12
XS-240W-A and XS-250WX-A indoor ONT environmental specifications
Mounting
method
Temperature range and humidity
Altitude
On desk or wall
mounted
Operating: 23°F to 104°F (-5°C to 40°C)
ambient temperature
Contact your Nokia technical support
representative for more information
5% to 93% relative humidity,
non-condensing at 40°C
5.7
XS-240W-A and XS-250WX-A GEM ports and
T-CONTs
Table 13 lists the maximum number of supported T-CONTs and GEM ports.
56
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 13
5.8
XS-240W-A and XS-250WX-A unit data sheet
XS-240W-A and XS-250WX-A indoor ONT capacity for GEM ports
and T-CONTs
XS-240W-A and XS-250WX-A ONT
Maximum
Notes
GEM ports per indoor or outdoor ONT
124
124 are present; 122 are available, and 2 are
reserved for multicast and debugging
T-CONTs per indoor or outdoor ONT
32
32 are present; 31 are available, and 1 is
reserved for OMCI
XS-240W-A and XS-250WX-A functional
blocks
XS-240W-A and XS-250WX-A indoor ONTs are single-residence ONTs that support
Wireless (Wi-Fi) service. Wi-Fi service on these ONTs is compliant with the IEEE
802.11 standard and enabled or disabled using a WLAN button. In addition to the
Wi-Fi service, these ONTs transmit Ethernet packets to four RJ-45 Ethernet ports
and voice traffic to two RJ-11 POTS ports. These ONTs also feature XGPON1 fiber
optic, USB, and power connectors.
Figure 18 shows the functional blocks for the XS-240W-A ONT
Issue: 01
3FE-48631-AAAA-TCZZA
57
XS-240W-A and XS-250WX-A unit data sheet
Figure 18
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Functional blocks for XS-240W-A ONT
12V
NAND
Flash
DDR3
PBI
1x4
Header
DDR3
Conn
LEDs
Power
Regulators
SFP+
1.0V
UART
JTAG
GPIO
xPON
USB
USB
3.0
port
USB
USB
3.0
port
SoC
GE
PHY
PCM
SLAC+
SLIC
RJ-11 RJ-11
5V
3.3V
2.5V
GE
PHY
GE
PHY
GE
PHY
MDI
MDI
MDI
MDI
PCIe1
PCIe0
GE
Magnetics
GE
Magnetics
GE
Magnetics
GE
Magnetics
802.11ac
4x4
802.11n
3x3
RJ-45
RJ-45
RJ-45
RJ-45
Antenna
External
Antenna
External
28056
Figure 19 shows the functional blocks for the XS-250WX-A ONT.
58
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 19
XS-240W-A and XS-250WX-A unit data sheet
Functional blocks for XS-250WX-A ONT
12V
NAND
Flash
PBI
DDR3
DDR3
1x4
Header
UART
Conn
LEDs
Power
Regulators
SFP+
1.0V
JTAG
GPIO
xPON
USB
USB
3.0
port
USB
USB
3.0
port
SoC
GE
PHY
PCM
MDI
GE
PHY
MDI
5V
3.3V
2.5V
GE
PHY
MDI
GE
PHY
MDI
XFI
PCIe1
PCIe0
10G Base-T
XFI PHY
SLAC+
SLIC
GE
Magnetics
GE
Magnetics
GE
Magnetics
GE
Magnetics
MDI
802.11ac
4x4
802.11n
3x3
Antenna
External
Antenna
External
10G
Magnetics
RJ-11 RJ-11
RJ-45
RJ-45
RJ-45
RJ-45
RJ-45
Optional
28053
ONT SoC technology serves as the main hardware block for these ONTs; see
Figure 20.
Issue: 01
3FE-48631-AAAA-TCZZA
59
XS-240W-A and XS-250WX-A unit data sheet
Figure 20
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A ONT SoC hardware block
POTS ports
Control
processor
SoC
DSP
SoC Bridge
Ethernet
MACs
GPON
MAC
Ethernet ports
GPON
19421
ONT SoC technology consists of five key elements:
• GPON MAC
•
•
•
•
60
The Gigabit Passive Optical Network Media Access Control (GPON MAC)
element on the SoC terminates the GPON interface using an optical diplexer. This
interface supports GPON as described in G.984.3 (GPON TC Layer) ITU
specification.
Ethernet MAC
The SoC provides up to four GE MACs.
DSP interface
The Digital Signal Processor (DSP) provides voice processing for 2 POTS lines
with 3-way calling. The DSP has a dedicated 64 kbyte instruction cache and
shares a 32 kbyte data cache with the Control Processor. It provides up to 4
network processor cores, each at 800MHz.
Control Processor
The Control Processor features an integral memory management unit that
supports a dedicated 64 kbyte instruction cache and shares a single 32 kbyte data
cache with the DSP. The Control Processor and DSP also include a single
channel Data Management Application (DMA) controller with a 4 kbyte read
ahead low-latency Dynamic Random Access Memory (DRAM) access port.
Switch matrix
The Switch matrix provides an integrated data channel between the four GE
MACs, the GPON MAC, the DSP, the control processor, and the other integrated
elements such as flash memory, DRAM, and the local bus controller.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A unit data sheet
These ONTs can also interact with additional hardware components to support
functionality not provided by the SoC technology.
5.9
XS-240W-A and XS-250WX-A standards
compliance
XS-240W-A and XS-250WX-A indoor ONTs are compliant with the following
standards:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5.9.1
AINSI/FCC/UL
CE marking
China/CCC (hardware only)
EN 300-328 for 2.4GHz bands
EN 301-489 for EUT with WiFi
EN 301-893 for 5GHz bands
ETL
ETSI/CE/CB
G.711 support for FAX and modem connection
G.984 support GPON interface (framing)
G.984.2 support for Amd1, class B+
G.984.3 support for activation and password functions
G.984.3 support for AES with operator enable/disable on per port-ID level
G.984.3 support for FEC in both upstream and downstream directions
G.984.3 support for multicast using a single GEM Port-ID for all video traffic
G984.4 and G.983.2 support for ONT management and provisioning
G987.x support for XGPON TC layer
IECEE CB certification
IEEE 801.11 ac/n (Wi-Fi)
IEEE 802.1p QoS
IEEE 802.1q VLANs
IEEE 802.3x flow control
IEEE 802.3az, 802.3u, 802.3z
ITU-T G.9807.1 support for XSPON TC layer
Responsible party
Table 14 lists the party in the US responsible for this ONT.
Issue: 01
3FE-48631-AAAA-TCZZA
61
XS-240W-A and XS-250WX-A unit data sheet
Table 14
5.9.2
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Responsible party contact information
Legal Company name
Nokia USA Inc.
Address
2301 SUGAR BUSH RD. STE 300, RALEIGH,NC 27612
Phone, Fax
+1 919 850 6127
Energy-related products standby and off modes
compliance
Hereby, Nokia declares that the XS-240W-A and XS-250WX-A ONTs are in
compliance with the essential requirements and other relevant provisions of Directive
2009/125/EC together with Commission Regulation (EC) No 1275/2008 and
Commission Regulation (EC) No 801/2013.
The XS-240W-A and XS-250WX-A ONTS qualify as equipment with high network
availability (HiNA) functionality. Since the main purpose of XS-240W-A and
XS-250WX-A ONTs is to provide network functionality with HiNA 7 days /24 hours,
the modes Off/Standby, Power Management, and Networked Standby are
inappropriate.
For information about the type and number of network ports, see “XS-240W-A and
XS-250WX-A interfaces and interface capacity” in this chapter.
For information about power consumption, see “XS-240W-A and XS-250WX-A
detailed specifications” in this chapter.
5.9.3
FCC statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
62
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
5.9.4
XS-240W-A and XS-250WX-A unit data sheet
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an uncontrolled
environment and it also complies with Part 15 of the FCC RF Rules. This equipment
must be installed and operated in accordance with provided instructions and the
antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter. End-users and installers must
be provided with antenna installation instructions and consider removing the
no-collocation statement.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
this device may not cause harmful interference, and
this device must accept any interference received, including interference that
may cause undesired operation.
Caution — Any changes or modifications not expressly
approved by the party responsible for compliance could void
the user's authority to operate the equipment.
5.10
XS-240W-A and XS-250WX-A special
considerations
XS-240W-A and XS-250WX-A are package P ONTs.
5.10.1
Wi-Fi service
XS-240W-A and XS-250WX-A indoor ONTs feature Wi-Fi service as well as voice
and data services. Wi-Fi is a wireless networking technology that uses radio waves
to provide wireless HSI and network connections. This ONT complies with the IEEE
802.11 standards, which the Wi-Fi Alliance defines as the basis for Wi-Fi technology.
5.10.1.1
Wi-Fi physical features
XS-240W-A and XS-250WX-A indoor ONTs have the following physical features that
assist in providing Wi-Fi service:
• 7 internal antennae: 3 for 2.4G and 4 for 5G
• WLAN button for enabling and disabling Wi-Fi service
• one Wi-Fi Protected Setup (WPS) push button (for 2.4G and 5G) for adding
WPS-enabled wireless devices
Issue: 01
3FE-48631-AAAA-TCZZA
63
XS-240W-A and XS-250WX-A unit data sheet
5.10.1.2
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Wi-Fi standards and certifications
The Wi-Fi service on XS-240W-A and XS-250WX-A indoor ONTs supports the
following IEEE standards and Wi-Fi Alliance certifications:
• certified for IEEE 802.11ac/b/g/n standards
• WPA support including WPA-PSK
• certified for WPA2-Personal and WPA2-Enterprise
5.10.1.3
Wi-Fi GUI features
XS-240W-A and XS-250WX-A indoor ONTs have HTML-based Wi-Fi configuration
GUIs.
5.10.2
XS-240W-A and XS-250WX-A ONT considerations
and limitations
Table 15 lists the considerations and limitations for Package P XS-240W-A and
XS-250WX-A ONTs.
Table 15
XS-240W-A and XS-250WX-A ONT considerations and limitations
Considerations and limitations
Some voice features are configurable on a per ONT basis, including Call Waiting, Call Hold, 3-Way Calling, and
Call Transfer.
The following voice features / GSIP parameters are configurable on a per-Client/ per-ONT basis (not
per-Subscriber):
•
•
•
•
•
•
Enable Caller ID and Enable Caller Name ID
Digitmap and the associated Interdigit and Critical timers and Enter key parameters
Warmline timer is enabled per subscriber, but the warmline timer value is configured per ONT and must
have a lower value than the Permanent time
Miscellaneous timers: Permanent, Timed-release, Reanswer, Error-tone, and CW-alert timers
Features / functions: Message waiting mode, WMWI refresh interval, DTMF volume level
Service Codes for the following features: CCW, Call Hold and Warmline
The following features are not supported in Release 5.6: port triggering, port mirroring, parental control (access
restrictions), and policy-based forwarding (in IP routing and QoS configuration).
This device is restricted to indoor use.
64
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Install an XS-240W-A or XS-250WX-A indoor ONT
6 Install an XS-240W-A or
XS-250WX-A indoor ONT
6.1 Purpose
6.2 General
6.3 Prerequisites
6.4 Recommended tools
6.5 Safety information
6.6 Procedure
6.1
Purpose
This chapter provides the steps to install an XS-240W-A or XS-250WX-A indoor
ONT.
6.2
General
The steps listed in this chapter describe mounting and cabling for XS-240W-A or
XS-250WX-A indoor ONTs.
6.3
Prerequisites
You need the following items before beginning the installation:
• all required cables
6.4
Recommended tools
You need the following tools for the installation:
•
•
•
•
Issue: 01
#2 Phillips screwdriver
1/4 in. (6 mm) flat blade screwdriver
wire strippers
fiber optic splicing tools
3FE-48631-AAAA-TCZZA
65
Install an XS-240W-A or XS-250WX-A indoor ONT
•
•
•
•
•
6.5
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
RJ-45 cable plug crimp tool
voltmeter or multimeter
optical power meter
drill and drill bits
paper clip
Safety information
Read the following safety information before installing the unit.
Danger 1 — Hazardous electrical voltages and currents can
cause serious physical harm or death. Always use insulated
tools and follow proper safety precautions when connecting or
disconnecting power circuits.
Danger 2 — Make sure all sources of power are turned off and
have no live voltages present on feed lines or terminals. Use a
voltmeter to measure for voltage before proceeding.
Danger 3 — Always contact the local utility company before
connecting the enclosure to the utilities.
Warning — This equipment is ESD sensitive. Proper ESD
protections should be used when removing the fiber access
cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
66
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Install an XS-240W-A or XS-250WX-A indoor ONT
Note 1 — Observe the local and national laws and regulations
that may be applicable to this installation.
Note 2 — Observe the following:
• The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local
authorities and practices take precedent when there is
conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service
personnel.
• Indoor ONTs must be installed with cables that are suitably
rated and listed for indoor use.
• See the detailed specifications in the XS-240W-A and
XS-250WX-A unit data sheet for the temperature ranges for
these ONTs.
6.6
Procedure
Use this procedure to install an XS-240W-A or XS-250WX-A indoor ONT.
Place the indoor ONT unit:
On the flat surface, such as a desk or shelf, or in the stand provided with the ONT kit;
go to step 3.
Note — The XS-240W-A or XS-250WX-A ONT cannot be stacked with
another ONT or with other equipment. The ONT mounting requirements
are:
•
•
•
Issue: 01
allow a minimum 100 mm clearance above the top cover
allow a minimum 50 mm clearance from the side vents
do not place any heat source directly above the top cover or below the
bottom cover
On a wall, go to step 2.
Mount the ONT on a wall using the wall mounting bracket (3FE 46917 AA) shown in Figure
21.
3FE-48631-AAAA-TCZZA
67
Install an XS-240W-A or XS-250WX-A indoor ONT
Figure 21
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-240W-A and XS-250WX-A wall mounting bracket
28187
Figure 22 shows the ONT mounted in the wall bracket. Be careful not to bend the cables.
Figure 22
XS-240W-A and XS-250WX-A ONT in wall mounting bracket
28189
68
Review the connection locations as shown in Figures 23 and 24.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Figure 23
Install an XS-240W-A or XS-250WX-A indoor ONT
XS-240W-A ONT connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
USB 3.0 UPS power
(2)
supply
Ethernet
RJ-45 (4)
28054
Figure 24
XS-250WX-A connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
LAN 10G
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
Ethernet
RJ-45 (4)
USB 3.0 UPS power
10 G
connection
(2)
supply
28051
Note — The 10 GE UNI port is only featured on the XS-250WX-A.
Connect the Ethernet cables to the RJ-45 ports; see Figure 23 or 24 for the location of the
RJ-45 ports.
Route the POTS cables directly to the RJ-11 ports as per local practices.
The POTS port to the left is labeled TEL1 for Line 1 while the port on the right is labeled TEL2
for Line 2, as shown in Figure 23 or 24.
Issue: 01
3FE-48631-AAAA-TCZZA
69
Install an XS-240W-A or XS-250WX-A indoor ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
For the XS-250WX-A ONT, connect the fiber optic cable with APC adapter into the 10GE
connector; see Figure 24 for the location of the 10GE connector.
Danger — Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius
in the cable can result in damage to the optic fiber.
Note — Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC fiber
optic pigtail cable.
Install the power supply according to manufacturer specifications.
Note — Observe the following:
•
Power up the ONT unit by using the power switch.
If used, enable the Wi-Fi service:
10
70
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12VDC, 3A.
Locate the WLAN button on the ONT; see Figure 23 or 24 for location of the WLAN
button.
ii
Press the WLAN button to change the status of the Wi-Fi service.
If used, enable the WPS service.
Locate the WPS buttons on the ONT; see Figure 23 or 24 for location of the WPS
buttons for 2.4G and 5G Wi-Fi.
ii
Press the WPS buttons to change the status of the Wi-Fi Protected Service.
11
Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
Cabling Installation Guide.
12
Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
13
If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide.
14
If necessary, reset the ONT.
15
Issue: 01
Install an XS-240W-A or XS-250WX-A indoor ONT
Locate the Reset button on a XS-240W-A or XS-250WX-A indoor ONT as shown in
Figure 23 or 24.
ii
Insert the end of a straightened paper clip or other narrow object into the hole in the
Reset button to reset the ONT.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
71
Install an XS-240W-A or XS-250WX-A indoor ONT
72
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Replace an XS-240W-A or XS-250WX-A indoor ONT
7 Replace an XS-240W-A or
XS-250WX-A indoor ONT
7.1 Purpose
7.2 General
7.3 Prerequisites
7.4 Recommended tools
7.5 Safety information
7.6 Procedure
7.1
Purpose
This chapter provides the steps to replace XS-240W-A or XS-250WX-A indoor
ONTs.
7.2
General
The steps listed in this chapter describe mounting and cabling for XS-240W-A or
XS-250WX-A indoor ONTs.
7.3
Prerequisites
You need the following items before beginning the installation:
• all required cables
7.4
Recommended tools
You need the following tools for replacing the ONT:
•
•
•
•
Issue: 01
#2 Phillips screwdriver
1/4 in. (6 mm) flat blade screwdriver
wire strippers
fiber optic splicing tools
3FE-48631-AAAA-TCZZA
73
Replace an XS-240W-A or XS-250WX-A indoor ONT
•
•
•
•
7.5
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
RJ-45 cable plug crimp tool
voltmeter or multimeter
optical power meter
drill and drill bits
Safety information
Read the following safety information before replacing the unit.
Danger 1 — Hazardous electrical voltages and currents can
cause serious physical harm or death. Always use insulated
tools and follow proper safety precautions when connecting or
disconnecting power circuits.
Danger 2 — Make sure all sources of power are turned off and
have no live voltages present on feed lines or terminals. Use a
voltmeter to measure for voltage before proceeding.
Danger 3 — Always contact the local utility company before
connecting the enclosure to the utilities.
Warning — This equipment is ESD sensitive. Proper ESD
protections should be used when removing the fiber access
cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note 1 — Observe the local and national laws and regulations
that may be applicable to this installation.
Note 2 — Observe the following:
• The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local
authorities and practices take precedent when there is
conflict between the local standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service
personnel.
• Indoor ONTs must be installed with cables that are suitably
rated and listed for indoor use.
• See the detailed specifications in the XS-240W-A and
XS-250WX-A unit data sheet for the ONT temperature
ranges for these ONTs.
74
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
7.6
Replace an XS-240W-A or XS-250WX-A indoor ONT
Procedure
Use this procedure to replace an XS-240W-A or XS-250WX-A indoor ONT.
Deactivate the ONT services at the P-OLT.
If you are using the SLID feature, this step is not required. The ONT and the services can
remain in service (IS).
Use the RTRV-ONT command to verify the ONT status and th associated services.
Record the serial number or the SLID of the ONT displayed in the command output.
Example:
RTRV-ONT::ONT-1-1-1-1-1;
ii
If the ONT is in service, place the ONT in OOS state.
Example:
ED-ONT::ONT-1-1-1-1-1;
Figure 25
If used, disable the Wi-Fi service by pressing the WLAN button; see Figure 25 for 26 for the
location of the WLAN button.
XS-240W-A ONT connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
Ethernet
RJ-45 (4)
USB 3.0 UPS power
(2)
supply
28054
Issue: 01
3FE-48631-AAAA-TCZZA
75
Replace an XS-240W-A or XS-250WX-A indoor ONT
Figure 26
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
XS-250WX-A ONT connections
ON/OFF
WPS
LED
WLAN RST
TEL 1
TEL 2
LAN 1
LAN 2
LAN 3
LAN 4
LAN 10G
USB 1
USB 2
UPS
ON/OFF
WPS
on/off
LEDs
on/off Wireless
on/off
Reset
POTS
RJ-11 (2)
Ethernet
RJ-45 (4)
10 G
USB 3.0 UPS power
connection
(2)
supply
28051
Power down the unit by using the on/off power switch; see Figure 25 or 26 for the on/off
switch.
Note that the 10 GE UNI port is only featured on the XS-250WX-A.
Disconnect the POTS, Ethernet, and power cables from the ONT; see Figure 25 or 26 for the
connector locations on the XS-240W-A and XS-250WX-A indoor ONT.
Unplug the fiber optic cable with APC connector from the ONT; see Figure 25 or 26 for the
location of the fiber optic port.
Danger — Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Replace the ONT with a new unit.
Connect the Ethernet cables directly to the RJ-45 ports; see Figure 25 or 26 for the location
of the RJ-45 ports.
Connect the POTS cables directly to the RJ-11 ports as per local practices; see Figure 25 or
26 for the location of the RJ-11 ports.
The RJ-11 port to the left is labeled TEL1 for Line 1 while the port on the right is labeled TEL2
for Line 2.
76
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Replace an XS-240W-A or XS-250WX-A indoor ONT
If required, have approved service personnel who are trained to work with optic fiber clean
the fiber optic connection. See the 7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide for more information about fiber optic handling, inspection, and
cleaning.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
10
For the XS-250WX-A ONT, connect the fiber optic cable with APC adapter into the APC
connector. Figure 26 shows the location of the fiber optic connector.
Danger — Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend radius
in the cable can result in damage to the optic fiber.
Note — Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC fiber
optic pigtail cable.
11
Install the power supply according to manufacturer specifications.
Note — Observe the following:
•
Issue: 01
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12VDC, 3A.
12
Power up the unit by using the power on/off switch.
13
If used, enable the Wi-Fi service by pressing the WLAN button; see Figure 25 or 26 for the
location of the WLAN button.
14
If used, enable the WPS service.
Locate the WPS buttons on the ONT; see Figure 25 or 26 for location of the WPS
buttons for 2.4G and 5G Wi-Fi.
ii
Press the WPS buttons to change the status of the Wi-Fi Protected Service.
3FE-48631-AAAA-TCZZA
77
Replace an XS-240W-A or XS-250WX-A indoor ONT
15
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and
Troubleshooting Guide for more information.
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the operations and
maintenance documentation for the OLT for more details.
16
Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and
Cabling Installation Guide.
17
Activate and test the services; see the 7368 Hardware and Cabling Installation Guide.
18
If necessary, reset the ONT.
19
78
Locate the Reset button on a XS-240W-A or XS-250WX-A indoor ONT as shown in
Figure 25 or 26.
ii
Insert the end of a straightened paper clip or other narrow object into the hole in the
Reset button to reset the ONT.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
8 Configure an XS-240W-A or
XS-250WX-A indoor ONT
8.1 General
8.2 HGU mode GUI configuration
8.1
General
Please refer to the configuration information provided with your OLT for the software
configuration procedure for an XS-240W-A or XS-250WX-A ONT.
For HTTP configuration procedures, please refer to the 7368 ISAM ONT
Configuration, Management, and Troubleshooting Guide.
8.2
HGU mode GUI configuration
Use the procedures below to use the web-based GUI for the XS-240W-A or
XS-250WX-A in HGU mode. This mode is preset at delivery.
A home gateway unit (HGU) is a home networking device, used as a gateway to
connect devices in the home through fiber to the Internet. An HGU provides a variety
of features for the home network including routing and firewall capability. By using
the HGU, users can connect all smart equipment in their home, including personal
computers, set-top boxes, mobile phones, and other consumer electronics devices,
to the Internet.
8.2.1
Login
Use the procedure below to login to the web-based GUI for the XS-240W-A or
XS-250WX-A.
Procedure 6
Login to web-based GUI
Open a web browser and enter the IP address of the ONT in the address bar.
The login window appears.
The default gateway IP address is http://192.168.1.254. You can connect to this IP address
using your web browser after connecting your PC to one of Ethernet ports of the ONT. The
static IP address of your PC must be in the same 192.168.1.x subnet as the ONT.
Issue: 01
3FE-48631-AAAA-TCZZA
79
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Enter your username and password in the Log in window, as shown in Figure 27.
The default user name is AdminGPON. The default password for OPID ALCL is ALC#FGU.
Figure 27
Web login window
Caution — Pressing the Reset button for less than 10 seconds reboots
the ONT; pressing the Reset button for 10 seconds resets the ONT to the
factory defaults.
Note — If you forget the current username and password, press the
reset button for 5 s and the default values for the username and password
will be recovered at startup.
Click Login. The Device Information screen appears.
Note — To help protect the security of your Internet connection, the
application displays a pop-up reminder to change both the Wi-Fi
password and the ONT password.
To increase password security, use a minimum of 10 characters,
consisting of a mix of numbers and upper and lower case letters.
8.2.2
STOP. This procedure is complete.
Device and connection status
XS-240W-A and XS-250WX-A ONTs support the retrieval of a variety of device and
connection information, including:
• device information
• LAN status
• WAN status
80
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
•
•
•
•
•
Procedure 7
Configure an XS-240W-A or XS-250WX-A indoor
ONT
WAN status IPv6
Home networking information
optics module status
statistics
voice information
Device information retrieval
Select Status > Device Information from the top-level menu in the 10G PON Gateway
window, as shown in Figure 28.
Figure 28
Device Information window
Table 16 describes the fields in the Device Information window.
Table 16
Device Information parameters
Field
Description
Device Name
Name on the ONT
Vendor
Name of the vendor
Serial Number
Serial number of the ONT
Hardware version
Hardware version of the ONT
Boot version
Boot version of the ONT
Software version
Software version of the ONT
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
81
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Chipset
Chipset of the ONT
Lot Number
Production date of the ONT
Device Running Time
Amount of time the device has run since
last reset in hours, minutes, and seconds
(2 of 2)
82
Click Refresh to update the displayed information.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 8
Configure an XS-240W-A or XS-250WX-A indoor
ONT
LAN status retrieval
Select Status > LAN Status from the top-level menu in the 10G PON Gateway window, as
shown in Figure 29.
Figure 29
LAN status window
Table 17 describes the fields in the LAN status window.
Table 17
LAN status parameters
Field
Description
Wireless Information
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
83
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Wireless Status
Indicates whether the wireless is on or off
Wireless Channel
Wireless channel number
SSID Name
Name of each SSID
Wireless Encryption Status
Encryption type used on the wireless connection
Wireless Rx Packets
Number of packets received on the wireless connection
Wireless Tx Packets
Number of packets transmitted on the wireless connection
Wireless Rx Bytes
Number of bytes received on the wireless connection
Wireless Tx Bytes
Number of bytes transmitted on the wireless connection
Power Transmission (mW)
Power of the wireless transmission, in mW
Ethernet Information
Ethernet Status
Indicates whether the Ethernet connection is on or off
Ethernet IP Address
IP address of the Ethernet connection
Ethernet Subnet Mask
Subnet Mask of the Ethernet connection
Ethernet MAC Address
MAC address of the Ethernet connection
Ethernet Rx Packets
Number of packets received on the Ethernet connection
Ethernet Tx Packets
Number of packets transmitted on the Ethernet connection
Ethernet Rx Bytes
Number of bytes received on the Ethernet connection
Ethernet Tx Bytes
Number of bytes transmitted on the Ethernet connection
LAN 1 to 4 and LAN 5 (10G)
information
This panel displays the following information for each LAN:
status (up or down)
duplex mode (full or auto)
max bit rate
errors received
errors sent
packets received
packets sent
bytes received
bytes sent
•
•
•
•
•
•
•
•
•
(2 of 2)
84
Click Refresh to update the displayed information.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 9
Configure an XS-240W-A or XS-250WX-A indoor
ONT
WAN status retrieval
Select Status > WAN Status from the top-level menu in the 10G PON Gateway window, as
shown in Figure 30.
Figure 30
WAN status window
Table 18 describes the fields in the WAN status window.
Table 18
WAN status parameters
Field
Description
WAN connection list
Drop-down menu listing all WAN connections. The connection shown is the
connection for which WAN status will be shown.
Connection Mode
Connection mode of the WAN connection
Enable/Disable
Select this checkbox to enable the WAN connection
VLAN
VLAN ID
WAN Link Status
Whether the WAN link is up or down
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
85
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
IPv4 Address
IPv4 address
Netmask
Netmask
Gateway
IPv4 gateway address
Primary DNS
Primary Domain Name Server
Second DNS
Secondary Domain Name Server
PON Link Status
Whether the PON link is up or down
Tx Packets
Number of packets transmitted on the WAN connection
Rx Packets
Number of packets received on the WAN connection
Tx Dropped
Number of packets dropped on the transmit WAN connection
Rx Dropped
Number of packets dropped on the receive WAN connection
Err Packets
Number of errored packets on the WAN connection
(2 of 2)
86
Click Refresh to update the displayed information.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 10
Configure an XS-240W-A or XS-250WX-A indoor
ONT
WAN status IPv6 retrieval
Select Status > WAN Status IPv6 from the top-level menu in the 10G PON Gateway window,
as shown in Figure 31.
Figure 31
WAN status IPv6 window
Table 19 describes the fields in the WAN status IPv6 window.
Table 19
WAN status IPv6 parameters
Field
Description
WAN connection list
Drop-down menu listing all WAN connections. The connection
shown is the connection for which WAN status will be shown.
Enable/Disable
Select this checkbox to enable the WAN connection
VLAN
VLAN ID
WAN Link Status
Whether the WAN link is up or down
IPv6 Address
IPv6 address that identifies the device and its location
IPv6 Prefix
IPv6 Prefix
IPv6 Gateway
IPv6 Gateway address
Primary DNS
Primary Domain Name Server
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
87
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Second DNS
Secondary Domain Name Server
PON Link Status
Whether the PON link is up or down
Tx Packets
Number of packets transmitted on the WAN connection
Rx Packets
Number of packets received on the WAN connection
Tx Dropped
Number of packets dropped on the transmit WAN connection
Rx Dropped
Number of packets dropped on the receive WAN connection
Err Packets
Number of errored packets on the WAN connection
(2 of 2)
88
Click Refresh to update the displayed information.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 11
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Home networking information retrieval
Select Status > Home Networking from the top-level menu in the 10G PON Gateway window,
as shown in Figure 32.
Figure 32
Home networking information window
Table 20 describes the fields in the Home networking window.
Table 20
Home networking parameters
Field
Description
Local Interface
Ethernet
Table displays the number of Ethernet connections and their settings
Wireless
Table displays the number of wireless connections and their settings
Wireless Settings
Network Name
Name of the wireless network
Access Point
Address of the wireless access point
Local Devices
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
89
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Table entry
Each entry indicates the status (active or inactive), connection type, device name, IP
address, hardware address, and IPv4 address allocation of each connected local device.
(2 of 2)
Click Delete to delete a particular local device connection.
Click Refresh to update the displayed information.
STOP. This procedure is complete.
Procedure 12
Optics module status retrieval
Select Status > Optics Module Status from the top-level menu in the 10G PON Gateway
window, as shown in Figure 33.
Figure 33
Optics module status window
Table 21 describes the fields in the Optics module status window.
90
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 21
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Optics module status parameters
Field
Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
Optics Module Temperature (ONT ANI-ONT-Side Optical
Measurements)
Optics module temperature, measured in C
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Received optics signal level at 1490 nm,
measured in dBm
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)
Transmitted optics signal level at 1310 nm,
measured in dBm
Lower (ONT ANI-ONT-Side Optical Measurements-Optical
Threshold)
Lower optical threshold, measured in dBm
Upper (ONT ANI-ONT-Side Optical Measurements-Optical
Threshold)
Upper optical threshold, measured in dBm
Click Refresh to update the displayed information.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
91
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 13
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Statistics retrieval
Select Status > Statistics from the top-level menu in the 10G PON Gateway window, as
shown in Figure 34.
Figure 34
Statistics window
The Statistics window displays the statistical details for the WAN and each LAN line, such as
the bytes, packets, and errors.
92
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 14
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Voice information retrieval
Select Status > Voice Information from the top-level menu in the 10G PON Gateway window,
as shown in Figure 35.
Figure 35
Voice Information window
Table 22 describes the fields in the Voice Information window.
Table 22
Voice Information parameters
Field
Description
Line
Select the POTS line: 1 or 2
Line Status
Status of the selected POTS line:
Disabled: the line is disabled
Up: the line is registered
Registering: the line is registering
Error: the line failed to register
Softswitch(1)
Phone
number(1)
Proxy IP address; blank if the line is not registered
Phone number configured for the selected telephone line
Register Status
Registration status of the selected POTS port: registered or
unregistered
Register Error Code
Error code for the unregistered POTS port
User Agent
User Agent: IP
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
93
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Register Error Reason
Error reason for the unregistered POTS port
(2 of 2)
Note
(1)
This field is only visible at the adminGPON level; it is not visible at the userAdmin level.
Click Refresh to update the displayed information.
STOP. This procedure is complete.
8.2.3
Network configuration
XS-240W-A and XS-250WX-A ONTs also support network configuration, including:
•
•
•
•
•
•
•
•
•
•
•
94
LAN
LAN IPv6
WAN
WAN DHCP
Wireless 2.4GHz
Wireless 5GHz
wireless scheduling
IP Routing
DNS
TR-069
QoS
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 15
Configure an XS-240W-A or XS-250WX-A indoor
ONT
LAN networking configuration
Select Network > LAN from the top-level menu in the 10G PON Gateway window, as shown
in Figure 36.
Figure 36
LAN network window
Table 23 describes the fields in the LAN network window.
Table 23
LAN network parameters
Field
Description
All Ports to Bridge Mode
Select this checkbox to set all ports to bridge mode
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
95
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Port Mode Port 1 - 4 and Port 5 (10G)
Drop-down port mode for each port: Route mode or bridge mode
IPv4 Address
IP Address of the ONT
Subnet Mask
Subnet mask of the ONT
DHCP enable
Select this checkbox to enable DHCP
DHCP Start IP Address
Starting DHCP IP address
DHCP End IP Address
Ending DHCP IP address
DHCP Lease Time
DHCP lease time (in min)
Primary DNS
Primary DNS identifier
Secondary DNS
Secondary DNS identifier
Static DHCP Entry MAC Address
MAC address for the static DHCP
Static DHCP Entry IPv4 Address
IPv4 address for the static DHCP
(2 of 2)
Select the mode for each port.
Click Save.
Enter the DHCP configuration information.
Click Save.
Enter the Static DHCP information.
Click Add.
You can also use this panel to delete a Static DHCP MAC address or IPv4 address.
96
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 16
Configure an XS-240W-A or XS-250WX-A indoor
ONT
LAN IPv6 networking configuration
Select Network > LAN_IPv6 from the top-level menu in the 10G PON Gateway window, as
shown in Figure 37.
Figure 37
LAN IPv6 network window
Table 24 describes the fields in the LAN IPv6 network window.
Table 24
LAN IPv6 network parameters
Field
Description
DNS Server
Choose a DNS server from the drop-down menu.
prefix config
Choose a prefix config option from the drop-down menu, either
WANConnection (prefix will be obtained from the WAN) or Static (enables you
to enter the prefix).
prefix
This field appears if you selected the “Static” option for the “prefix config” field.
Type a connection.
Interface
This field appears if you selected the Wan Connection option for the “prefix
config” field. Choose a WAN connection interface from the drop-down menu.
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
97
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
DHCP Start IP Address
Enter the starting DHCP IP address.
DHCP End IP Address
Enter the ending DHCP IP address.
Whether the address info
through DCHP
Select this checkbox to enable address information retrieval through DHCP.
Whether other info obtained
through DHCP
Select this checkbox to enable retrieval of other information through DHCP.
Maximum interval for
periodic RA messages
Enter the maximum interval (in seconds) for periodic Router Advertisement
messages. The interval range is from 4 to 1800.
Minimum interval for
periodic RA messages
Enter the minimum interval (in seconds) for periodic Router Advertisement
messages. The interval range is from 4 to 1800.
(2 of 2)
98
Choose a DNS server, prefix config, and interface.
Select or enter the DHCP configuration information.
Enter the maximum and minimum intervals for RA messages.
Click Save/Apply.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 17
Configure an XS-240W-A or XS-250WX-A indoor
ONT
WAN networking configuration
Select Network > WAN from the top-level menu in the 10G PON Gateway window, as shown
in Figure 38.
Figure 38
WAN network window
Table 25 describes the fields in the WAN network window.
Table 25
WAN network parameters
Field
Description
WAN Connection List
Choose a WAN connection from the drop-down menu to set the
connection parameters
Connection Type
Select a connection type: IPoE or PPPoE
IP Mode
Choose an IP mode from the drop-down menu: IPv4 or IPv6
Enable/Disable
Select this checkbox to enable the WAN connection
NAT
Select this checkbox to enable NAT
Service
Select the checkboxes to enable service types for this connection
Enable VLAN
Select this checkbox to enable VLAN
VLAN ID
Enter the VLAN ID
VLAN PRI
Enter the VLAN PRI
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
99
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
WAN IP Mode
Choose an IP mode from the drop-down menu
Manual DNS
Enter a DNS
(2 of 2)
Configure a specific WAN connection.
Click Save.
STOP. This procedure is complete.
Procedure 18
WAN DHCP configuration
Select Network > WAN DHCP from the top-level menu in the 10G PON Gateway window, as
shown in Figure 39.
Figure 39
WAN DHCP window
Table 26 describes the fields in the WAN DHCP window.
100
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 26
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
WAN DHCP parameters
Field
Description
WAN Connection List
Choose a WAN connection from the drop-down menu
DHCP Option 50 persistent
Select this checkbox to enable DHCP Option 50
Enable DHCP Option 60
Select this checkbox to enable DHCP Option 60 (vendor class identifier)
Vendor Class Identifier 60
Enter the identifier for the vendor class
Enable DHCP Option 61
Select this checkbox to enable DHCP Option 61 (client identifier)
Configure a WAN DHCP option.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
101
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 19
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
WiFi 2.4G networking configuration
Select Network > Wireless 2.4GHz from the top-level menu in the 10G PON Gateway
window, as shown in Figure 40.
Figure 40
Wireless 2.4GHz network window
Table 27 describes the fields in the Wireless 2.4GHz network window.
Table 27
Wireless 2.4GHz network parameters
Field
Description
Enable
Select this checkbox to enable WiFi
(1 of 2)
102
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Field
Description
Mode
Choose a Wi-Fi mode from the drop-down menu:
Bandwidth
•
•
•
•
•
auto (b/g/n)
b/g
Choose from:
•
•
•
20 MHz
40 MHz
20/40 MHz
Channel
Choose a channel from the drop-down menu or choose Auto to have the channel
automatically assigned
Transmitting Power
Choose a percentage for the transmitting power from the drop-down menu:
•
•
•
•
Low (25%)
Medium (50%)
High (75%)
Maximum (100%)
WMM
Select this checkbox to enable or disable wireless multi media
Total MAX Users
Enter the total number of MAX users
SSID Select
Choose the SSID from the drop-down menu
SSID Name
Enter the SSID name
Enable SSID
Enable or disable SSID from this drop-down menu
SSID Broadcast
Enable or disable SSID broadcast from this drop-down menu
Port Mode
Choose a port mode from the drop-down menu:
MAX Users
Encryption Mode
WPA Version
•
•
Route
Bridge
Enter the number of MAX users
Choose an encryption mode from the drop-down menu:
•
•
•
•
OPEN
WEP
WPA/WPA2 Personal
WPA/WPA2 Enterprise (1)(2)
Choose a WPA version from the drop-down menu:
•
•
•
WPA1
WPA2
WPA1/WPA2
WPA Encryption
Mode
Choose a WPA encryption mode from the drop-down menu:
WPA Key
Enter the WPA key
Enable WPS
Enable or disable WPS from this drop-down menu
•
•
•
TKIP
AES
TKIP/AES
(2 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
103
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Notes
(1)
When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options are no longer available: WPA
version, WPA encryption mode, WPA key, Enable WPS, WPS mode.
(2)
104
When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options become available: Primary
RADIUS server, port and password; Secondary RADIUS server, port, and password; RADIUS accounting port.
Configure the wireless 2.4 GHz connection.
If you have enabled and configured WPS, click WPS connect.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 20
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Wireless 5GHz networking configuration
Select Network > Wireless 5GHz from the top-level menu in the 10G PON Gateway window,
as shown in Figure 41.
Figure 41
Wireless 5GHz network window
Table 28 describes the fields in the Wireless 5GHz network window.
Table 28
Wireless 5GHz network parameters
Field
Description
Enable
Select this checkbox to enable WiFi
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
105
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Field
Description
Bandwidth
Choose from:
•
•
•
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
20 MHz
40 MHz
80 MHz
Channel
Choose a channel from the drop-down menu or choose Auto to have the
channel automatically assigned
Transmitting Power
Choose a percentage for the transmitting power from the drop-down menu:
•
•
•
•
Low (20%)
Medium (40%)
High (60%)
Maximum (100%)
WMM
Select this checkbox to enable or disable wireless multi media
Enable MU-MIMO
Choose Enable or disable MU-MIMO from this drop-down menu
The default is Enable, which enables users and wireless terminals to
communicate with each other.
MU-MIMO may decrease Wi-Fi performance for clients who do not support it,
in which case Nokia recommends that you choose Disable.
Total MAX Users
Enter the total number of MAX users
DFS re-entry
Select this checkbox to enable or disable DFS re-entry
SSID Select
Choose the SSID from the drop-down menu
SSID Name
Change the name of the selected SSID
Enable SSID
Choose Enable or disable SSID from this drop-down menu
SSID Broadcast
Choose Enable or disable SSID broadcast from this drop-down menu
Port Mode
Choose Route or Bridge from the drop-down menu
MAX Users
Enter the number of MAX users
Encryption Mode
Choose an encryption mode from the drop-down menu:
OPEN
WEP
WPA/WPA2 Personal
WPA/WPA2 Enterprise (1)(2)
•
•
•
•
WPA Key
Enter the WPA key
Enable WPS
Choose Enable or disable WPS from this drop-down menu
(2 of 2)
Notes
(1)
When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options are no longer available: WPA
version, WPA encryption mode, WPA key, Enable WPS, WPS mode.
(2)
106
When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options become available: Primary
RADIUS server, port and password; Secondary RADIUS server, port, and password; RADIUS accounting port.
Configure the wireless 5GHZ connection.
If you have enabled and configured WPS, click WPS connect.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Click Save.
STOP. This procedure is complete.
Procedure 21
Wireless scheduling
Select Network > Wireless Schedule from the top-level menu in the 10G PON Gateway
window, as shown in Figure 42.
Figure 42
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Wireless Schedule network window
Select the Schedule Function checkbox to turn the wireless signal off for the configured
period.
Select the Start, End, and Recurrence Pattern rules for turning the wireless signal off.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
107
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 22
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
IP Routing configuration
Note that forwarding policy is not supported in Release 5.6.
Select Network > IP Routing from the top-level menu in the 10G PON Gateway window, as
shown in Figure 43.
Figure 43
IP Routing network window
Table 29 describes the fields in the IP Routing network window.
Table 29
IP Routing network parameters
Field
Description
Enable Routing
Select this checkbox to enable routing
Destination IP Address
Enter the destination IP address
Destination Netmask
Enter the destination network mask
Gateway
Enter the gateway address
(1 of 2)
108
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Field
Description
IPv4 Interface
Choose a WAN connection previously created in the WAN network window from
the drop-down menu
(2 of 2)
Enter the routing information.
Click Add.
STOP. This procedure is complete.
Procedure 23
DNS configuration
Select Network > DNS from the top-level menu in the 10G PON Gateway window, as shown
in Figure 44.
Figure 44
Issue: 01
DNS network window
3FE-48631-AAAA-TCZZA
109
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 30 describes the fields in the DNS network window.
Table 30
110
DNS network parameters
Field
Description
DNS Proxy Enabled
Select this checkbox to enable DNS proxy
Domain Name
Domain name
IPv4 Address
Domain IP address
Origin Domain
Origin domain name
New Domain
New domain name
Enter the domain name and IP address and click Add.
If required, associate an origin domain with a new domain, click Add.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 24
Configure an XS-240W-A or XS-250WX-A indoor
ONT
TR-069 configuration
Select Network > TR-069 from the top-level menu in the 10G PON Gateway window, as
shown in Figure 45.
Figure 45
TR-069 network window
Table 31 describes the fields in the TR-069 network window.
Table 31
Issue: 01
TR-069 network parameters
Field
Description
Periodic Inform Enable
Select this checkbox to enable periodic inform updates
Periodic Inform Interval(s)
Time between periodic inform updates, in seconds
URL
URL of the auto-configuration server
Username
Username used to log in to the auto-configuration server
Password
Password used to log in to the auto-configuration server
Connect Request Username
Username used to log in to the ONT
Connect Request Password
Password used to log in to the ONT
Configure TR-069 by entering the required information.
3FE-48631-AAAA-TCZZA
111
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Click Save.
STOP. This procedure is complete.
Procedure 25
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
QoS configuration
Note that forwarding policy is not supported in Release 5.6.
Select Network > QoS Config from the top-level menu in the 10G PON Gateway window.
Figure 46 shows the QoS Config window for QoS L2 (Layer 2 packet sizes).
The window for QoS L3 shows additional fields, as described in Table 32.
Figure 46
QoS Config window (L2)
Table 32 describes the fields in the QoS Config window.
112
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 32
Configure an XS-240W-A or XS-250WX-A indoor
ONT
QoS Config parameters
Field
Description
Type
Choose a QoS type from the drop-down menu: L2 or L3
Source MAC
Enter the source MAC.
Select the Exclude checkbox to exclude the source MAC
Interface
Choose an interface from the drop-down menu
802.1p Mark
Enter the value for the 802.1p (range: 0-7)
DSCP Mark
Enter the value for the DSCP mark (range: 0-63)
Additional fields for L3
Protocol
Select a protocol from the drop-down menu, or select the Exclude checkbox
Application
Select an application from the drop-down menu
Source IP and
Source IP Mask
Enter the values for the source IP and IP mask, or select the Exclude checkbox
Destination IP and
Destination IP Mask
Enter the values for the destination IP and IP mask, or select the Exclude checkbox
Source Port and
Source Port Max
Enter the values for the source port and port max (highest port number) or select the
Exclude checkbox
Destination Port and
Destination Port Max
Enter the values for the destination port and port max (highest port number), or select
the Exclude checkbox
Choose a QoS type from the drop-down menu: L2 or L3.
Configure a QoS policy.
Click Add to add a QoS policy.
STOP. This procedure is complete.
8.2.4
Security configuration
XS-240W-A and XS-250WX-A ONT also supports security configuration, including:
•
•
•
•
Issue: 01
firewall
MAC filter
IP filter
URL filter
3FE-48631-AAAA-TCZZA
113
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
• DMZ and ALG
• access control
Note that parent control is not supported in Release 5.6.
Procedure 26
Firewall configuration
Select Security > Firewall from the top-level menu in the 10G PON Gateway window, as
shown in Figure 47.
Figure 47
Firewall window
Firewall security applies only to services provided by the ONT. Internet access from the LAN
side is not affected by this firewall.
Three security levels are available: Low, Medium, and High.
At the Low level, pre-routing is supported: port forwarding, DMZ, host application, and host
drop. Also supported are application services: DDNS, DHCP, DNS, H248, IGMP, NTP client,
SSH, Telnet, TFTP, TR-069, and VoIP.
At the Medium level, pre-routing is supported: port forwarding, DMZ, host application, and
host drop. Also supported are application services: DDNS, DHCP, DNS, H248, IGMP, NTP
client, TFTP, TR-069, and VoIP. The following types of ICMP messages are permitted: echo
request and reply, destination unreachable, and TTL exceeded. Other types of ICMP
messages are blocked. DNS proxy is supported from LAN to WAN but not from WAN to LAN.
At the High level, pre-routing and application services are not supported. UDP Port 8000 can
be used to access the services, for example FTP can use 8021 and Telnet can use 8023.
Regular UDP cannot be used. RG access is permitted via the LAN side but not via the WAN
side.
114
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Table 33 describes the fields in the firewall window.
Table 33
Firewall parameters
Field
Description
Security level
Choose the security level from the drop-down menu: low, medium, or high
Attack Protect
(Protection against DoS or
DDoS attacks)
Choose enable or disable attack protect from the drop-down menu
The default is disable
Configure the firewall.
Click Save.
STOP. This procedure is complete.
Procedure 27
MAC filter configuration
Select Security > Mac Filter from the top-level menu in the 10G PON Gateway window, as
shown in Figure 48.
Figure 48
MAC filter window
Table 34 describes the fields in the MAC filter window.
Issue: 01
3FE-48631-AAAA-TCZZA
115
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Table 34
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
MAC filter parameters
Field
Description
Enable MAC filter
Select this checkbox to enable the MAC filter
Mac Address
Select a MAC address from the drop-down menu or enter the address in the text field
Mac Filter Mode
Choose the MAC filter mode from this drop-down menu: Blocked or Allowed
Click Refresh to update the information.
Configure a MAC filter.
Click Add.
STOP. This procedure is complete.
Procedure 28
IP filter configuration
Select Security > IP filter from the top-level menu in the 10G PON Gateway window, as
shown in Figure 49.
Figure 49
IP filter window
Table 35 describes the fields in the IP filter window.
116
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 35
IP filter parameters
Field
Description
Enable IP Filter
Select this checkbox to enable an IP filter
Mode
Choose an IP filter mode from the drop-down menu:
Internal Client
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
•
•
Drop for upstream
Drop for downstream
Choose an internal client from the drop-down menu:
•
•
Customer setting - uses the IP address input below
IP - uses the connecting devices' IP to the ONT
Local IP Address
Local IP address
Source Subnet Mask
Source subnet mask
Remote IP Address
Remote IP address
Destination Subnet Mask
Destination subnet mask
Protocol
Choose an application protocol or all from the drop-down menu
Configure the IP filter.
Click Add.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
117
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 29
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
URL filter configuration
Select Security > URL Filter from the top-level menu in the 10G PON Gateway window, as
shown in Figure 50.
Figure 50
URL Filter window
Note — You cannot use URL filtering for HTTPS. The URL is encrypted
when using HTTPS.
Table 36 describes the fields in the URL Filter window.
Table 36
118
URL Filter parameters
Field
Description
Enable URL filter
Select the checkbox to enable the URL filter
URL filter type
Select the checkbox for Exclude URL or Include URL
URL Address
Type the URL address
Port Number
Type the port number; the default is 80
Configure the URL Filter.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Click Add Filter.
STOP. This procedure is complete.
Procedure 30
Configure an XS-240W-A or XS-250WX-A indoor
ONT
DMZ and ALG configuration
Select Security > DMZ and ALG from the top-level menu in the 10G PON Gateway window,
as shown in Figure 51.
Figure 51
DMZ and ALG window
Table 37 describes the fields in the DMZ and ALG window.
Table 37
DMZ and ALG parameters
Field
Description
ALG Config
Select the checkboxes to enable the protocols to be supported by the ALG: FTP,
TFTP, SIP, H323, RTSP, L2TP, IPSEC, PPTP
DMZ Config
Issue: 01
WAN Connection List
Choose a WAN connection from the drop-down menu
Enable DMZ
Select this checkbox to enable DMZ on the chosen WAN connection
DMZ IP Address
Choose Customer Setting and enter the DMZ IP address or choose the IP address
of a connected device from the drop-down menu
3FE-48631-AAAA-TCZZA
119
Configure an XS-240W-A or XS-250WX-A indoor
ONT
120
Configure ALG.
Click Save ALG.
Configure DMZ.
Click Save DMZ.
STOP. This procedure is complete.
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 31
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Access control configuration
This procedure describes how to configure the access control level (ACL).
Note 1 — ACL takes precedence over the firewall policy.
Note 2 — The trusted network object will be shared for all WAN
connections; it is not applied individually to a WAN connection.
Select Security > Access Control from the top-level menu in the 10G PON Gateway window,
as shown in Figure 52.
Figure 52
Access Control window
Table 38 describes the fields in the Access Control window.
Table 38
Access control parameters
Field
Description
WAN
Choose a connection from the drop-down menu
Trusted Network Enable
Select this checkbox to enable trusted network
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
121
Configure an XS-240W-A or XS-250WX-A indoor
ONT
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
ICMP, Telnet, SSH, HTTP,
TR-069, HTTPS
Select an access control level for each protocol:
WAN side: Allow, Deny, or Trusted Network Only
LAN side: Allow or Deny
Source IP Start
Enter a start IP address for the new subnet trusted network
Source IP End
Enter an end IP address for the new subnet trusted network
(2 of 2)
Select a WAN connection from the drop-down menu.
Select the checkbox to enable Trusted Network.
Select an access control level for each of the four protocols: ICMP, SSH, HTTP, and TR-069
for both the WAN and the LAN side.
Click Save.
Optionally, add one or more subnet trusted networks.
The maximum number of entries is 32.
You can also use the Source IP fields to delete a previously created entry for a subnet trusted
network.
8.2.5
STOP. This procedure is complete.
Application configuration
XS-240W-A and XS-250WX-A ONT also supports application configuration,
including:
•
•
•
•
•
•
port forwarding
DDNS
NTP
USB
UPnP and DLNA
voice setting
Note that port triggering is not supported in release 5.6.
122
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 32
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Port forwarding configuration
Select Application > Port forwarding from the top-level menu in the 10G PON Gateway
window, as shown in Figure 53.
Figure 53
Port forwarding window
Table 39 describes the fields in the port forwarding window.
Table 39
Port forwarding parameters
Field
Description
Application Name
Choose an application name from the drop-down menu
WAN Port
WAN port range
LAN Port
LAN port range
Internal Client
Choose a connected device from the drop-down menu and enter the associated IP
address
Protocol
Choose the port forwarding protocol from the drop-down menu:
•
•
•
TCP
UDP
TCP/UDP
Enable Mapping
Select this checkbox to enable mapping
WAN Connection List
Choose a WAN connection from the drop-down menu
Note: only active devices are shown on this menu
Issue: 01
3FE-48631-AAAA-TCZZA
123
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Configure port forwarding.
Click Add.
STOP. This procedure is complete.
Procedure 33
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
DDNS configuration
Select Application > DDNS from the top-level menu in the 10G PON Gateway window, as
shown in Figure 54.
Figure 54
DDNS window
Table 40 describes the fields in the DDNS window.
Table 40
DDNS parameters
Field
Description
WAN Connection List
Choose a WAN connection from the drop-down menu
Enable DDNS
Select this checkbox to enable DDNS on the chosen WAN connection
ISP
Choose an ISP from the drop-down menu.
Domain Name
Domain name
Username
Username
(1 of 2)
124
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Field
Description
Password
Password
Configure an XS-240W-A or XS-250WX-A indoor
ONT
(2 of 2)
Configure DDNS.
Click Save.
STOP. This procedure is complete.
Procedure 34
NTP configuration
Select Application > NTP from the top-level menu in the 10G PON Gateway window, as
shown in Figure 55.
Figure 55
Issue: 01
NTP window
Select the checkbox to enable NTP service.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
125
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 35
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
USB configuration
You can connect USB storage devices and USB printers to the USB ports of the device. The USB
menu enables you to configure FTP and SFTP servers for your USB storage devices.
You can also use the USB menu to enable and disable USB printer sharing across clients on the
LAN.
The USB connected devices are shown in overview table on the bottom of the USB window.
The device incorporates a CUPS server to enable USB printer sharing across the LAN by using
the RAW print-through protocol. When a USB printer is connected to the device, it can be
configured on LAN clients by referring to
http://:631/printers/
as a shared printer, where  refers to the DNS name or the IP address of the device
and the  is displayed in the connected USB device table of the USB page. The
USB printer driver must be installed on the LAN client to execute print jobs. When an error
prevents the print job from being completed, a generic error message is returned to the LAN client.
Up to four print jobs at a time are supported.
Select Application > USB from the top-level menu, as shown in Figure 56.
Figure 56
USB window
Table 41 describes the fields in the USB window.
126
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Table 41
Configure an XS-240W-A or XS-250WX-A indoor
ONT
USB parameters
Field
Description
Enable FTP server
Select this checkbox to enable using an FTP server
Username
Username for FTP server
Password
Password for FTP server
Re-enter Password
Password for FTP server
Enable SFTP server
Select this checkbox to enable using an SFTP server
Enable SFTP for Remote Access
Select this checkbox to enable SFTP for remote access
Username
Username for SFTP server
Password
Password for SFTP server
Re-enter Password
Password for SFTP server
Enable Printer Sharing
Select this checkbox to enable printer sharing
Printer sharing is disabled by default
Connected USB devices
Issue: 01
For each printer that is connected to the ONT, the following fields are
displayed:
• Host Number for example: Printer1, Printer2
• Device Name: name or identification for the USB device
• Format: for a USB printer, the printing protocol is RAW; for a USB
storage device, this field displays the storage format
• Total space (applies only to a USB storage device)
• Free space (applies only to a USB storage device)
Configure USB.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
127
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 36
UPnP and DLNA configuration
Select Application > UPnP and DLNA from the top-level menu in the 10G PON Gateway
window, as shown in Figure 57.
Figure 57
128
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
UPnP and DLNA window
Select the Enable UPnP checkbox to enable UPnP.
Click Save/Apply.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 37
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Voice setting
Voice setting can only be uses in TR-069 mode.
Select Application > Voice Setting from the top-level menu in the 10G PON Gateway window,
as shown in Figure 58.
Figure 58
Voice setting window
Table 42 describes the fields in the Voice Setting window.
Issue: 01
3FE-48631-AAAA-TCZZA
129
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Table 42
Voice setting parameters
Field
Description
Outbound Proxy
Enter the SIP outbound proxy
Outbound Proxy Port
Enter the outbound proxy port
Proxy Server
Enter the proxy server
Proxy Port
Enter the proxy port
Register Server
Enter the register server
Register Port
Enter the register port
User Agent Domain
Enter the user agent domain
DTMF Mode
Choose InBand, rfc2822, Info, or Auto from the drop-down menu
FaxT38
Choose False or True from the drop-down menu
Line
Choose a line from the drop-down menu
Enable
Choose Enabled or Disabled from the drop-down menu
Directory Number
Enter a directory number
AuthUserName
Enter an authorized user name
AuthPassword
Enter a password for the user
Configure voice setting.
Click Save.
STOP. This procedure is complete.
8.2.6
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Maintenance
XS-240W-A and XS-250WX-A ONT also supports maintenance tasks, including:
•
•
•
•
•
•
•
•
130
change password
configure LOID
configure SLID
manage device
backup and restore
upgrade firmware
reboot device
restore factory defaults
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Configure an XS-240W-A or XS-250WX-A indoor
ONT
• diagnose WAN connections
• view log
Procedure 38
Password configuration
A password must adhere to the password rules, which are as follows:
•
•
•
•
•
the password may consist of uppercase letters, lowercase letters, digital numbers, and
the following special characters ! # + , - / @ _ : = ]
the password length must be from 8 to 24 characters
the first character must be a digital number or a letter
the password must contain at least two types of characters: numbers, letters, or special
characters
the same character must not appear more than 8 times in a row
When the password meets the password rules, the application displays the message “Your
password has been changed successfully”.
When the password does not meet the password rules, the application displays a message to
indicate which password rule has not been followed, for example:
•
•
•
•
Issue: 01
the password is too short
the password is too long
the first character cannot be a special character
there are not enough character classes
Select Maintenance > Password from the top-level menu in the GPON Home Gateway
window, as shown in Figure 59.
3FE-48631-AAAA-TCZZA
131
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Figure 59
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Password window
Table 43 describes the fields in the password window.
Table 43
132
Password parameters
Field
Description
New Password
New password (must adhere to the password rules described above)
Re-enter password
Must match the new password entered above exactly
Prompt message
Password prompt message
Configure the new password.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 39
Configure an XS-240W-A or XS-250WX-A indoor
ONT
LOID configuration
Select Maintain > LOID Config from the top-level menu in the 10G PON Gateway window, as
shown in Figure 60.
Figure 60
LOID Config window
Table 44 describes the fields in the LOID configuration window.
Table 44
LOID configuration parameters
Field
Description
LOID
Type the LOID; the maximum number of characters is 24
If the password is null, this field may be left blank
Password
Issue: 01
Type the password; the maximum number of characters is 12
Configure the LOID.
Click Save/Apply.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
133
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 40
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
SLID configuration
Select Maintain > SLID Configuration from the top-level menu in the 10G PON Gateway
window, as shown in Figure 61.
Figure 61
SLID configuration window
Table 45 describes the fields in the SLID configuration window.
Table 45
134
SLID configuration parameters
Field
Description
Current SLID
Displays current SLID
Input new SLID
Enter new SLID
SLID Mode
Choose a SLID mode from the drop-down menu.
Configure the new SLID.
Click Save.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 41
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Device management
Select Maintain > Device Management from the top-level menu in the 10G PON Gateway
window, as shown in Figure 62.
Figure 62
Device management window
Table 46 describes the fields in the Device management window.
Table 46
Issue: 01
Device management parameters
Field
Description
Host name
Choose a host from the drop-down menu
Alias
Enter an alias for the chosen host
Configure an alias for a specific host.
Click Add.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
135
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 42
Backup and restore
Select Maintain > Backup and Restore from the top-level menu in the 10G PON Gateway
window, as shown in Figure 63.
Figure 63
136
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Backup and Restore window
Click Select File and choose the backup file.
Click Import Config File to restore the ONT to the saved backup or click Export Config File to
export the current ONT configuration to the backup file.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 43
Upgrade firmware
Select Maintain > Firmware Upgrade from the top-level menu in the 10G PON Gateway
window, as shown in Figure 64.
Figure 64
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Firmware upgrade window
Click Select File and choose the firmware file.
Click Upgrade to upgrade the firmware.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
137
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 44
Reboot ONT
Select Maintain > Reboot Device from the top-level menu in the 10G PON Gateway window,
as shown in Figure 65.
Figure 65
138
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Reboot window
Click Reboot to reboot the ONT.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 45
Restore factory defaults
Select Maintain > Factory Default from the top-level menu in the 10G PON Gateway window,
as shown in Figure 66.
Figure 66
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Factory default window
Click Factory Default to reset the ONT to its factory default settings.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
139
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Procedure 46
Diagnose WAN connections
Select Maintain > Diagnose from the top-level menu in the 10G PON Gateway window, as
shown in Figure 67.
Figure 67
140
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Diagnose window
Choose a WAN connection to diagnose from the drop-down menu.
Enter the IP address or domain name.
Select the test type: ping, traceroute, or both.
Enter the number of ping attempts to perform (1 - 1000); the default is 4.
Enter a ping packet length (64-1024); the default is 64.
Enter the maximum number of trace hops (1-255); the default is 30.
Click Start Test. Results will be displayed at the bottom of the window.
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Click Cancel to cancel the test.
10
STOP. This procedure is complete.
Procedure 47
View log files
Select Maintain > Log from the top-level menu in the 10G PON Gateway window, as shown
in Figure 68.
Figure 68
Issue: 01
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Log window
3FE-48631-AAAA-TCZZA
141
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Choose a write level from the drop-down menu to determine which types of events are
recorded in the log file:
•
•
•
•
•
•
•
•
Emergency
Alert
Critical
Error
Warning
Notice
Informational
Debug
Choose a reading level from the drop-down menu to determine which types of events to
display from the log file:
•
•
•
•
•
•
•
•
8.2.7
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Emergency
Alert
Critical
Error
Warning
Notice
Informational
Debug
The log file is displayed at the bottom of the window.
STOP. This procedure is complete.
RG troubleshooting counters
The Troubleshooting Counters feature enables service providers and end users to
monitor the performance of their broadband connection.
Tests are run to retrieve upstream and downstream throughput, latency, and DNS
response time. The Troubleshooting Counters window also displays upstream and
downstream packet loss and Internet status.
Note that port mirroring is not supported in Release 5.6.
142
3FE-48631-AAAA-TCZZA
Issue: 01
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Procedure 48
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Retrieve Residential Gateway (RG) troubleshooting counters
Select RG Troubleshooting Counters from the left menu in the 10G PON Gateway window.
The RG Troubleshooting Counters window appears; see Figure 69.
Figure 69
RG Troubleshooting Counters window
Table 47 describes the fields in the RG Troubleshooting Counters window.
Table 47
RG Troubleshooting Counters parameters
Field
Description
WAN Connection List
Select a WAN connection from the list
(1 of 2)
Issue: 01
3FE-48631-AAAA-TCZZA
143
Configure an XS-240W-A or XS-250WX-A indoor
ONT
Field
US Throughput
7368 ISAM ONT XS-240W-A XS-250WX-A Product
Guide
Description
This test is used to determine the upstream throughput/speed
Click US Speed Test to specify the time for the upstream test
The default is weekly, performed at idle to a public server
DS Throughput
This test is used to determine the downstream throughput/speed
Click DS Speed Test to specify the time for the downstream test
The default is weekly, performed at idle to a public server
US Packet Loss
The number of upstream packages lost
DS Packet Loss
The number of downstream packages lost
Internet Status
Whether the broadband connections is active (UP) or not (DOWN)
Latency
This test is used to determine the lowest round-trip time in milliseconds by
pinging the target server multiple times
Click Latency Test to specify the time for the test
The default is weekly, performed at idle to a public server
DNS Response Time
This test is used to determine the lowest round-trip time in milliseconds by
sending a request to the target DNS server
Click DNS Response Test to specify the time for the test
The default is weekly, performed at idle to a public server
(2 of 2)
144
Configure the test times if desired.
Click Refresh to update the data.
STOP. This procedure is complete.
3FE-48631-AAAA-TCZZA
Issue: 01
Customer document and product support
Customer documentation
Customer Documentation Welcome Page
Technical Support
Customer Documentation Technical Support
Documentation feedback
Customer Documentation Feedback
Copyright 2018 Nokia.
3FE-48631-AAAA-TCZZA

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Nokia
Create Date                     : 2018:04:24 13:33:44Z
Modify Date                     : 2018:05:02 12:03:16-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08
Format                          : application/pdf
Creator                         : Nokia
Title                           : 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide
Creator Tool                    : FrameMaker 11.0.2
Metadata Date                   : 2018:05:02 12:03:16-04:00
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:a14e4664-43f2-4e7b-a527-e9f6a0b5903b
Instance ID                     : uuid:3b78c868-e6e8-4f5a-99ba-718ef23ef0a6
Page Mode                       : UseOutlines
Page Count                      : 146
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ADZRXS250WXAB

Navigation menu