Nokia Bell XS250WXAB 7368 Intelligent Services Access Manager CPE User Manual 7368 ISAM ONT XS 240W A XS 250WX A Product Guide
Nokia Shanghai Bell Co. Ltd. 7368 Intelligent Services Access Manager CPE 7368 ISAM ONT XS 240W A XS 250WX A Product Guide
Contents
- 1. User manual
- 2. Users Manual_revised0503
Users Manual_revised0503
7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 7368 Intelligent Services Access Manager ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 Nokia — Proprietary and confidential Use pursuant to applicable agreements 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Nokia is a registered trademark of Nokia Corporation. Other products and company names mentioned herein may be trademarks or tradenames of their respective owners. The information presented is subject to change without notice. No responsibility is assumed for inaccuracies contained herein. © 2018 Nokia. Contains proprietary/trade secret information which is the property of Nokia and must not be made available to, or copied or used by anyone outside Nokia without its written authorization. Not to be used or disclosed except in accordance with applicable agreements. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Preface 1 Preface This preface provides general information about the documentation set for optical network terminals (ONTs). 1.1 Scope This documentation set provides information about safety, features and functionality, ordering, hardware installation and maintenance, and software installation procedures for the current release. 1.2 Audience This documentation set is intended for planners, administrators, operators, and maintenance personnel involved in installing, upgrading, or maintaining the ONTs. 1.3 Required knowledge The reader must be familiar with general telecommunications principles. 1.4 Acronyms and initialisms The expansions and optional descriptions of most acronyms and initialisms appear in the glossary. 1.5 Assistance and ordering phone numbers Nokia provides global technical support through regional call centers. Phone numbers for the regional call centers are available at the following URL: http://support.alcatel-lucent.com. For ordering information, contact your Nokia sales representative. Issue: 01 3FE-48631-AAAA-TCZZA Preface 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 1.6 Nokia quality processes Nokia’s ONT quality practices are in compliance with TL 9000 requirements. These requirements are documented in the Fixed Networks Quality Manual 3FQ-30146-6000-QRZZA. The quality practices adequately ensure that technical requirements and customer end-point requirements are met. The customer or its representatives may be allowed to perform on-site quality surveillance audits, as agreed upon during contract negotiations 1.7 Safety information For safety information, see the appropriate safety guidelines chapter. 1.8 Documents Documents are available using ALED or OLCS. Procedure 1 To download a ZIP file package of the customer documentation Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. From the Technical Content for drop-down menu, choose the product. Click on Downloads: Electronic Delivery. Choose Documentation from the drop-down menu and click Next. Select the image from the drop-down menu and click Next. Follow the on-screen directions to download the file. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 2 Preface To access individual documents Individual PDFs of customer documents are also accessible through the Nokia Customer Support website. 1.9 Navigate to http://support.alcatel-lucent.com and enter your user name and password. If you are a new user and require access to this service, please contact your Nokia sales representative. From the Technical Content for drop-down menu, choose the product. Click on Manuals and Guides to display a list of customer documents by title and part number. You can filter this list using the Release drop-down menu. Click on the PDF to open or save the file. Special information The following are examples of how special information is presented in this document. Danger — Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards. Warning — Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems. Caution — Caution indicates that the described activity or situation may, or will, cause service interruption. Note — A note provides information that is, or may be, of special interest. Issue: 01 3FE-48631-AAAA-TCZZA Preface 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 1.9.1 Procedures with options or substeps When there are options in a procedure, they are identified by letters. When there are required substeps in a procedure, they are identified by roman numerals. Procedure 3 Example of options in a procedure At step 1, you can choose option a or b. At step 2, you must do what the step indicates. Procedure 4 This step offers two options. You must choose one of the following: This is one option. This is another option. You must perform this step. Example of required substeps in a procedure At step 1, you must perform a series of substeps within a step. At step 2, you must do what the step indicates. This step has a series of substeps that you must perform to complete the step. You must perform the following substeps: This is the first substep. ii This is the second substep. iii This is the third substep. You must perform this step. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 1.10 Preface Multiple PDF document search You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a common term. Adobe Reader displays the results in a single display panel. The results are grouped by PDF file, and you can expand the entry for each file. Note — The PDF files in which you search must be in the same folder. Procedure 5 To search multiple PDF files for a common term Open Adobe Acrobat Reader. Choose Edit→Search from the Acrobat Reader main menu. The Search PDF panel appears. Enter the search criteria. Click on the All PDF Documents In radio button. Select the folder in which to search using the drop-down menu. Click on the Search button. Acrobat Reader displays the search results. You can expand the entries for each document by clicking on the + symbol. Issue: 01 3FE-48631-AAAA-TCZZA Preface 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table of contents Preface.............................................................................................3 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.9.1 1.10 Scope ..........................................................................................................3 Audience......................................................................................................3 Required knowledge....................................................................................3 Acronyms and initialisms .............................................................................3 Assistance and ordering phone numbers ....................................................3 Nokia quality processes...............................................................................4 Safety information........................................................................................4 Documents ..................................................................................................4 Special information ......................................................................................5 Procedures with options or substeps...........................................................6 Multiple PDF document search ...................................................................7 ETSI ONT safety guidelines .........................................................17 2.1 2.1.1 2.1.2 2.2 2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.3 2.3.1 2.3.2 2.3.3 2.4 2.5 2.5.1 2.5.1.1 2.5.2 2.5.3 2.5.4 2.6 Safety instructions .....................................................................................17 Safety instruction boxes ............................................................................17 Safety-related labels..................................................................................18 Safety standards compliance ....................................................................19 EMC, EMI, and ESD compliance...............................................................19 Equipment safety standard compliance.....................................................19 Environmental standard compliance .........................................................20 Laser product standard compliance ..........................................................20 Resistibility requirements compliance .......................................................20 Acoustic noise emission standard compliance ..........................................20 Electrical safety guidelines ........................................................................20 Power supplies ..........................................................................................21 Cabling ......................................................................................................21 Protective earth .........................................................................................21 ESD safety guidelines ...............................................................................21 Laser safety guidelines..............................................................................21 Laser classification ....................................................................................22 Laser warning labels..................................................................................22 Transmit optical output ..............................................................................24 Normal laser operation ..............................................................................24 Location class............................................................................................25 Environmental requirements......................................................................25 ETSI environmental and CRoHS guidelines...............................27 3.1 3.1.1 3.1.2 3.1.2.1 3.1.2.2 Environmental labels .................................................................................27 Overview....................................................................................................27 Environmental related labels .....................................................................27 Products below Maximum Concentration Value (MCV) label....................27 Products containing hazardous substances above Maximum Concentration Value (MCV) label ..............................................................28 Hazardous Substances Table (HST).........................................................29 Other environmental requirements ............................................................29 3.2 3.3 Issue: 01 3FE-48631-AAAA-TCZZA 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 ONT environmental requirements .............................................................29 Storage ......................................................................................................29 Transportation ...........................................................................................30 Stationary use............................................................................................30 Thermal limitations ....................................................................................30 Material content compliance......................................................................30 End-of-life collection and treatment ...........................................................31 ANSI ONT safety guidelines ........................................................33 4.1 4.1.1 4.1.2 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.4 4.4.1 4.4.2 4.4.3 4.5 4.6 Safety instructions .....................................................................................33 Safety instruction boxes in customer documentation ................................33 Safety-related labels..................................................................................34 Safety standards compliance ....................................................................35 EMC, EMI, and ESD standards compliance..............................................36 Equipment safety standard compliance.....................................................36 Environmental standards compliance........................................................37 Laser product standards compliance.........................................................37 Resistibility requirements compliance .......................................................38 Laser safety guidelines..............................................................................38 Laser warning labels..................................................................................38 Laser classification ....................................................................................40 Transmit optical output ..............................................................................41 Normal laser operation ..............................................................................41 Location class............................................................................................41 Electrical safety guidelines ........................................................................42 Power supplies ..........................................................................................42 Cabling ......................................................................................................42 Protective earth .........................................................................................42 ESD safety guidelines ...............................................................................42 Environmental requirements......................................................................43 XS-240W-A and XS-250WX-A unit data sheet ............................45 5.1 5.2 5.2.1 5.3 XS-240W-A and XS-250WX-A part numbers and identification ................45 XS-240W-A and XS-250WX-A general description...................................48 TR69 authentication using TLS and CA certificates ..................................51 XS-240W-A and XS-250WX-A software and installation feature support.......................................................................................................52 XS-240W-A and XS-250WX-A interfaces and interface capacity..............52 XS-240W-A and XS-250WX-A connections and components ..................53 XS-240W-A and XS-250WX-A LEDs ........................................................53 XS-240W-A and XS-250WX-A detailed specifications ..............................55 XS-240W-A and XS-250WX-A GEM ports and T-CONTs.........................56 XS-240W-A and XS-250WX-A functional blocks.......................................57 XS-240W-A and XS-250WX-A standards compliance ..............................61 Responsible party......................................................................................61 Energy-related products standby and off modes compliance....................62 FCC statement ..........................................................................................62 FCC Radiation Exposure Statement .........................................................63 XS-240W-A and XS-250WX-A special considerations..............................63 Wi-Fi service..............................................................................................63 5.4 5.4.1 5.5 5.6 5.7 5.8 5.9 5.9.1 5.9.2 5.9.3 5.9.4 5.10 5.10.1 10 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Issue: 01 5.10.1.1 5.10.1.2 5.10.1.3 5.10.2 Wi-Fi physical features ..............................................................................63 Wi-Fi standards and certifications .............................................................64 Wi-Fi GUI features.....................................................................................64 XS-240W-A and XS-250WX-A ONT considerations and limitations .........64 Install an XS-240W-A or XS-250WX-A indoor ONT ....................65 6.1 6.2 6.3 6.4 6.5 6.6 Purpose .....................................................................................................65 General......................................................................................................65 Prerequisites..............................................................................................65 Recommended tools..................................................................................65 Safety information......................................................................................66 Procedure ..................................................................................................67 Replace an XS-240W-A or XS-250WX-A indoor ONT.................73 7.1 7.2 7.3 7.4 7.5 7.6 Purpose .....................................................................................................73 General......................................................................................................73 Prerequisites..............................................................................................73 Recommended tools..................................................................................73 Safety information......................................................................................74 Procedure ..................................................................................................75 Configure an XS-240W-A or XS-250WX-A indoor ONT .............79 8.1 8.2 8.2.1 8.2.2 8.2.3 8.2.4 8.2.5 8.2.6 8.2.7 General......................................................................................................79 HGU mode GUI configuration....................................................................79 Login..........................................................................................................79 Device and connection status....................................................................80 Network configuration................................................................................94 Security configuration ..............................................................................113 Application configuration .........................................................................122 Maintenance ............................................................................................130 RG troubleshooting counters...................................................................142 3FE-48631-AAAA-TCZZA 11 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 12 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide List of figures Issue: 01 ETSI ONT safety guidelines .........................................................17 Figure 1 Figure 2 Figure 3 Figure 4 PSE certification ........................................................................................19 Laser product label ....................................................................................22 Laser classification label............................................................................23 Laser warning labels..................................................................................24 ETSI environmental and CRoHS guidelines...............................27 Figure 5 Figure 6 Figure 7 Products below MCV value label...............................................................28 Products above MCV value label ..............................................................28 Recycling/take back/disposal of product symbol .......................................31 ANSI ONT safety guidelines ........................................................33 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Sample safety label on the ONT equipment..............................................35 Sample laser product label showing CDRH 21 CFR compliance..............37 Laser product label ....................................................................................39 Laser classification label............................................................................39 Laser warning labels..................................................................................40 Sample laser product safety label on the ONT equipment ........................41 XS-240W-A and XS-250WX-A unit data sheet ............................45 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 XS-240W-A or XS-250WX-A in wall mounting bracket .............................49 XS-240W-A ONT connections...................................................................50 XS-250WX-A ONT connections ................................................................50 XS-250WX-A indoor ONT LEDs................................................................54 Functional blocks for XS-240W-A ONT .....................................................58 Functional blocks for XS-250WX-A ONT...................................................59 XS-240W-A and XS-250WX-A ONT SoC hardware block ........................60 Install an XS-240W-A or XS-250WX-A indoor ONT ....................65 Figure 21 Figure 22 Figure 23 Figure 24 XS-240W-A and XS-250WX-A wall mounting bracket ..............................68 XS-240W-A and XS-250WX-A ONT in wall mounting bracket ..................68 XS-240W-A ONT connections...................................................................69 XS-250WX-A connections .........................................................................69 Replace an XS-240W-A or XS-250WX-A indoor ONT.................73 Figure 25 Figure 26 XS-240W-A ONT connections...................................................................75 XS-250WX-A ONT connections ................................................................76 Configure an XS-240W-A or XS-250WX-A indoor ONT .............79 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Web login window......................................................................................80 Device Information window........................................................................81 LAN status window ....................................................................................83 WAN status window...................................................................................85 WAN status IPv6 window ..........................................................................87 Home networking information window.......................................................89 Optics module status window ....................................................................90 Statistics window .......................................................................................92 Voice Information window..........................................................................93 3FE-48631-AAAA-TCZZA 13 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 Figure 64 Figure 65 Figure 66 Figure 67 Figure 68 Figure 69 14 LAN network window .................................................................................95 LAN IPv6 network window.........................................................................97 WAN network window................................................................................99 WAN DHCP window ................................................................................100 Wireless 2.4GHz network window ...........................................................102 Wireless 5GHz network window ..............................................................105 Wireless Schedule network window ........................................................107 IP Routing network window .....................................................................108 DNS network window ..............................................................................109 TR-069 network window ..........................................................................111 QoS Config window (L2)..........................................................................112 Firewall window .......................................................................................114 MAC filter window....................................................................................115 IP filter window ........................................................................................116 URL Filter window ...................................................................................118 DMZ and ALG window.............................................................................119 Access Control window ...........................................................................121 Port forwarding window ...........................................................................123 DDNS window .........................................................................................124 NTP window ............................................................................................125 USB window ............................................................................................126 UPnP and DLNA window.........................................................................128 Voice setting window ...............................................................................129 Password window....................................................................................132 LOID Config window................................................................................133 SLID configuration window ......................................................................134 Device management window...................................................................135 Backup and Restore window ...................................................................136 Firmware upgrade window ......................................................................137 Reboot window ........................................................................................138 Factory default window............................................................................139 Diagnose window ....................................................................................140 Log window..............................................................................................141 RG Troubleshooting Counters window....................................................143 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide List of tables ETSI ONT safety guidelines .........................................................17 Table 1 Safety labels ..............................................................................................18 ANSI ONT safety guidelines ........................................................33 Table 2 Safety labels ..............................................................................................34 XS-240W-A and XS-250WX-A unit data sheet ............................45 Table 3 Table 4 Table 5 Table 6 Table 7 Identification of XS-240W-A indoor ONTs .................................................45 Identification of XS-250WX-A indoor ONTs...............................................46 XS-240W-A and XS-250WX-A power supply ............................................48 XS-240W-A and XS-250WX-A comparison...............................................48 XS-240W-A and XS-250WX-A indoor ONT interface connection capacity .....................................................................................................52 XS-240W-A and XS-250WX-A indoor ONT physical connections ............53 XS-240W-A and XS-250WX-A indoor ONT LEDs.....................................54 XS-240W-A and XS-250WX-A indoor ONT physical specifications ..........55 XS-240W-A and XS-250WX-A indoor ONT power consumption specifications .............................................................................................56 XS-240W-A and XS-250WX-A indoor ONT environmental specifications .............................................................................................56 XS-240W-A and XS-250WX-A indoor ONT capacity for GEM ports and T-CONTs ............................................................................................57 Responsible party contact information ......................................................62 XS-240W-A and XS-250WX-A ONT considerations and limitations .........64 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT .............79 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 Table 29 Table 30 Table 31 Table 32 Table 33 Table 34 Table 35 Table 36 Device Information parameters .................................................................81 LAN status parameters..............................................................................83 WAN status parameters ............................................................................85 WAN status IPv6 parameters ....................................................................87 Home networking parameters ...................................................................89 Optics module status parameters..............................................................91 Voice Information parameters ...................................................................93 LAN network parameters...........................................................................95 LAN IPv6 network parameters...................................................................97 WAN network parameters .........................................................................99 WAN DHCP parameters..........................................................................101 Wireless 2.4GHz network parameters.....................................................102 Wireless 5GHz network parameters........................................................105 IP Routing network parameters ...............................................................108 DNS network parameters ........................................................................110 TR-069 network parameters....................................................................111 QoS Config parameters...........................................................................113 Firewall parameters .................................................................................115 MAC filter parameters..............................................................................116 IP filter parameters ..................................................................................117 URL Filter parameters .............................................................................118 3FE-48631-AAAA-TCZZA 15 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 37 Table 38 Table 39 Table 40 Table 41 Table 42 Table 43 Table 44 Table 45 Table 46 Table 47 16 DMZ and ALG parameters ......................................................................119 Access control parameters ......................................................................121 Port forwarding parameters .....................................................................123 DDNS parameters ...................................................................................124 USB parameters ......................................................................................127 Voice setting parameters.........................................................................130 Password parameters..............................................................................132 LOID configuration parameters ...............................................................133 SLID configuration parameters................................................................134 Device management parameters ............................................................135 RG Troubleshooting Counters parameters..............................................143 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ETSI ONT safety guidelines 2 ETSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals (ONTs). 2.1 Safety instructions This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment. 2.1.1 Safety instruction boxes The safety instruction boxes are provided in the ONT customer documentation. Observe the instructions to meet safety requirements. The following is an example of the Danger box. Danger — Possibility of personal injury. The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm. Do not proceed beyond a Danger box until the indicated conditions are fully understood and met. The following is an example of the Warning box. Warning 1 — Possibility of equipment damage. Warning 2 — Possibility of data loss. The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data. Do not proceed beyond a warning until the indicated conditions are fully understood and met. Issue: 01 3FE-48631-AAAA-TCZZA 17 ETSI ONT safety guidelines 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box. Note — Information of special interest. The Note box provides information that assists the personnel working with ONTs. It does not provide safety-related instructions. 2.1.2 Safety-related labels The ONT equipment is labeled with the specific safety instructions and compliance information that is related to a variant of the ONT. Observe the instructions on the safety labels. Table 1 provides sample safety labels on the ONT equipment. Table 1 Safety labels Description Label text ESD warning Caution: This assembly contains an electrostatic sensitive device. Laser classification Class 1 laser product PSE marking These power supplies are Japan PSE certified and compliant with Japan VCCI emissions standards. Figure 1 shows the PSE certification. 18 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 1 ETSI ONT safety guidelines PSE certification This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Warning 19841 2.2 Safety standards compliance This section describes the ONT compliance with the European safety standards. 2.2.1 EMC, EMI, and ESD compliance The ONT equipment complies with the following EMC, EMI, and ESD requirements: • EN 300-328 v1.9.1 wide band data transmission standards for 2.4GHz bands • EN 300-386 V1.5.1: Electromagnetic Compatibility and Radio Spectrum Matters • • • • • 2.2.2 (ERM): Telecommunications Network Equipment; Electromagnetic Compatibility (EMC) requirements; Electrostatic Discharge (ESD) requirements EN 55022 (2006): Class B, Information Technology Equipment, Radio Disturbance Characteristics, limits and methods of measurement EN 55024 (2010): Information Technology Equipment, Immunity Characteristics, limits and methods of measurement European Council Directive 2004/108/EC EN 300-386 V1.4.1: 2008 EN 55022:2006 Class B (ONTs) Equipment safety standard compliance The ONT equipment complies with the requirements of EN 60950-1, Safety of Information Technology Equipment for use in a restricted location (per R-269). Issue: 01 3FE-48631-AAAA-TCZZA 19 ETSI ONT safety guidelines 2.2.3 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Environmental standard compliance The ONT equipment complies with the EN 300 019 European environmental standards. 2.2.4 Laser product standard compliance For most ONTs, the ONT equipment complies with EN 60825-1 and IEC 60825-2 for laser products. If there is an exception to this compliance regulation, you can find this information in the standards compliance section of the unit data sheet in this Product Guide. 2.2.5 Resistibility requirements compliance The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to over voltage and overcurrents. 2.2.6 Acoustic noise emission standard compliance The ONT equipment complies with EN 300 753 acoustic noise emission limit and test methods. 2.3 Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. Note 1 — The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards. Note 2 — The ONTs comply with BS EN 61140. 20 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 2.3.1 ETSI ONT safety guidelines Power supplies The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property. 2.3.2 Cabling The following are the guidelines regarding cables used for the ONT equipment: • All cables must be approved by the relevant national electrical code. • The cables for outdoor installation of ONTs must be suitable for outdoor use. • POTS wiring run outside the subscriber premises must comply with the requirements of local electrical codes. In some markets, the maximum allowed length of the outside run is 140 feet (43 m). If the outside run is longer, NEC requires primary protection at both the exit and entry points for the wire. 2.3.3 Protective earth Earthing and bonding of the ONTs must comply with the requirements of local electrical codes. 2.4 ESD safety guidelines The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment. Caution — This equipment is ESD sensitive. Proper ESD protections should be used when you enter the TELCO Access portion of the ONT. During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. 2.5 Laser safety guidelines Observe the following instructions when you perform installation, operations, and maintenance tasks on the ONT equipment. Issue: 01 3FE-48631-AAAA-TCZZA 21 ETSI ONT safety guidelines 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system. Danger — There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to the laser beam. Observe the following danger for laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules. Danger — Possibility of equipment damage. Risk of eye damage by laser radiation. 2.5.1 Laser classification The ONT is classified as a Class 1 laser product based on its transmit optical output. 2.5.1.1 Laser warning labels The following figures show the labels related to laser product, classification and warning. Figure 2 shows a laser product label. Figure 2 Laser product label 18455 Figure 3 shows a laser classification label. Laser classification labels may be provided in other languages. 22 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 3 ETSI ONT safety guidelines Laser classification label CLASS 1 LASER PRODUCT PRODUCTO LASER CLASE 1 CLASE 1 DEL LASER LASER CLASSE 1 18992 Figure 4 shows a laser warning label and an explanatory label for laser products. Labels and warning may be provided in other languages. The explanatory label provides the following information: • a warning that calls attention to the invisible laser radiation • an instruction against staring into the beam or viewing directly with optical instruments • wavelength • normal output power • maximum output power Issue: 01 3FE-48631-AAAA-TCZZA 23 ETSI ONT safety guidelines Figure 4 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W Max output power: yyy m W Laser Warning Label Laser Warning Label CLASS 1 LASER PRODUCT RAYONNEMENT LASER CLASSE 1 RAYONNEMENT LASER INVISIBLE EVITER TOUTE EXPOSITION AU FAISCEAU NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE CLASE 1 DEL LASER RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM. Laser Warning Label 18993 2.5.2 Transmit optical output The maximum transmit optical output of an ONT is +5 dBm. 2.5.3 Normal laser operation In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card. Eyes can be damaged when they exposed to a laser beam. Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module. Danger — Risk of eye damage by laser radiation. 24 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 2.5.4 ETSI ONT safety guidelines Location class Use cable supports and guides to protect the receptacles from strain. 2.6 Environmental requirements See the ONT technical specification documentation for more information about temperature ranges. During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Nokia recommends: • The door of the ONT not be opened until temperature inside and outside the enclosure has stabilized. • If the door of the ONT must be opened after a rapid change in temperature or humidity, use a dry cloth to wipe down the metal interior to prevent the risk of condensation. • When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened. Issue: 01 3FE-48631-AAAA-TCZZA 25 ETSI ONT safety guidelines 26 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ETSI environmental and CRoHS guidelines 3 ETSI environmental and CRoHS guidelines This chapter provides information about the ETSI environmental China Restriction of Hazardous Substances (CRoHS) regulations that govern the installation and operation of the optical line termination (OLT) and optical network termination (ONT) systems. This chapter also includes environmental operation parameters of general interest. 3.1 Environmental labels This section describes the environmental instructions that are provided with the customer documentation, equipment, and location where the equipment resides. 3.1.1 Overview CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold and imported in the territory of the mainland of the People’s Republic of China. EIP refers to products and their accessories manufactured by using electronic information technology, including electronic communications products and such subcomponents as batteries and cables. 3.1.2 Environmental related labels Environmental labels are located on appropriate equipment. The following are sample labels. 3.1.2.1 Products below Maximum Concentration Value (MCV) label Figure 5 shows the label that indicates a product is below the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products). Products with this label are recyclable. The label may be found in this documentation or on the product. Issue: 01 3FE-48631-AAAA-TCZZA 27 ETSI environmental and CRoHS guidelines Figure 5 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Products below MCV value label 18986 3.1.2.2 Products containing hazardous substances above Maximum Concentration Value (MCV) label Figure 6 shows the label that indicates a product is above the maximum concentration value, as defined by standard SJ/T11363-2006 (Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products). The number contained inside the label indicates the Environment-Friendly User Period (EFUP) value. The label may be found in this documentation or on the product. Figure 6 28 Products above MCV value label 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ETSI environmental and CRoHS guidelines Together with major international telecommunications equipment companies, Nokia has determined it is appropriate to use an EFUP of 50 years for network infrastructure equipment and an EFUP of 20 years for handsets and accessories. These values are based on manufacturers' extensive practical experience of the design, manufacturing, maintenance, usage conditions, operating environments, and physical condition of infrastructure and handsets after years of service. The values reflect minimum values and refer to products operated according to the intended use conditions. See “Hazardous Substances Table (HST)” for more information. 3.2 Hazardous Substances Table (HST) This section describes the compliance of the OLT and ONT equipment to the CRoHS standard when the product and subassemblies contain hazardous substances beyond the MCV value. This information is found in this user documentation where part numbers for the product and subassemblies are listed. It may be referenced in other OLT and ONT documentation. In accordance with the People’s Republic of China Electronic Industry Standard Marking for the Control of Pollution Caused by Electronic Information Products (SJ/T11364-2006), customers may access the Nokia Hazardous Substance Table, in Chinese, from the following location: • http://www.nokia-sbell.com/wwwroot/images/upload/private/1/media/ChinaRoHS.p df 3.3 Other environmental requirements Observe the following environmental requirements when handling the P-OLT or ONT equipment. 3.3.1 ONT environmental requirements See the ONT technical specification documentation for more information about temperature ranges. 3.3.2 Storage According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in Class 1.1, weather-protected, temperature-controlled locations. Issue: 01 3FE-48631-AAAA-TCZZA 29 ETSI environmental and CRoHS guidelines 3.3.3 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Transportation According to EN 300-019-1-2 - Class 2.3, transportation of the OLT equipment must be in packed, public transportation with no rain on packing allowed. 3.3.4 Stationary use According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment must be in a temperature-controlled location, with no rain allowed, and with no condensation allowed. 3.3.5 Thermal limitations When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The thermal limitations for OLT operation in a CO or CEV are: • • • • 3.3.6 operating temperature: 5°C to 40°C (41°F to 104°F) short-term temperature: –5°C to 50°C (23°F to 122°F) operating relative humidity: 5% to 85% short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg Material content compliance European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment. This Directive applies to electrical and electronic products placed on the EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment. Nokia products shipped to the EU after 1 July 2006 comply with the EU RoHS Directive. Nokia has implemented a material/substance content management process. The process is described in: Nokia process for ensuring RoHS Compliance (1AA002660031ASZZA). This ensures compliance with the European Union Directive 2011/65/EU on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS2). With the process equipment is assessed in accordance with the Harmonised Standard EN50581:2012 (CENELEC) on Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances. 30 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3.3.7 ETSI environmental and CRoHS guidelines End-of-life collection and treatment Electronic products bearing or referencing the symbol shown in Figure 7, when put on the market within the European Union (EU), shall be collected and treated at the end of their useful life, in compliance with applicable EU and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product, such as heavy metals or batteries, the environment and human health may be negatively impacted as a result of inappropriate disposal. Note — In the European Union, a solid bar under the symbol for a crossed-out wheeled bin indicates that the product was put on the market after 13 August 2005. Figure 7 Recycling/take back/disposal of product symbol At the end of their life, the OLT and ONT products are subject to the applicable local legislations that implement the European Directive 2012/19EU on waste electrical and electronic equipment (WEEE). There can be different requirements for collection and treatment in different member states of the European Union. In compliance with legal requirements and contractual agreements, where applicable, Nokia will offer to provide for the collection and treatment of Nokia products bearing the logo shown in Figure 7 at the end of their useful life, or products displaced by Nokia equipment offers. For information regarding take-back of equipment by Nokia, or for more information regarding the requirements for recycling/disposal of product, contact your Nokia account manager or Nokia take back support at sustainability.global@nokia.com. Issue: 01 3FE-48631-AAAA-TCZZA 31 ETSI environmental and CRoHS guidelines 32 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ANSI ONT safety guidelines 4 ANSI ONT safety guidelines This chapter provides information about the mandatory regulations that govern the installation and operation of the optical network terminals or units (ONTs or ONUs) in the North American or ANSI market. 4.1 Safety instructions This section describes the safety instructions that are provided in the ONT customer documentation and on the equipment. 4.1.1 Safety instruction boxes in customer documentation The safety instruction boxes are provided in the ONT customer documentation. Observe the instructions to meet safety requirements. The following is an example of the Danger box. Danger — Possibility of personal injury. The Danger box indicates that the described activity or situation may pose a threat to personal safety. It calls attention to a situation or procedure which, if not correctly performed or adhered to, may result in death or serious physical harm. Do not proceed beyond a Danger box until the indicated conditions are fully understood and met. The following is an example of the Warning box. Warning 1 — Possibility of equipment damage. Warning 2 — Possibility of data loss. The Warning box indicates that the described activity or situation may, or will, cause equipment damage, loss of data, or serious performance problems. It identifies a possible equipment-damaging situation or provides essential information to avoid the degradation of system operations or data. Do not proceed beyond a warning until the indicated conditions are fully understood and met. Issue: 01 3FE-48631-AAAA-TCZZA 33 ANSI ONT safety guidelines 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide The following is an example of the Caution box. Caution 1 — Possibility of service interruption. Caution 2 — Service interruption. The Caution box indicates that the described activity or situation may, or will, cause service interruption. Do not proceed beyond a caution until the indicated conditions are fully understood and met. The following is an example of the Note box. Note — Information of special interest. The Note box provides information that assists the personnel working with ONTs. It does not provide safety-related instructions. 4.1.2 Safety-related labels The ONT equipment is labeled with specific safety compliance information and instructions that are related to a variant of the ONT. Observe the instructions on the safety labels. Table 2 provides examples of the text in the various ONT safety labels. Table 2 Safety labels Description Label text UL compliance Communication service equipment US listed. Type 3R enclosure Rainproof. TUV compliance Type 3R enclosure - Rainproof. ESD warning Caution: This assembly contains electrostatic sensitive device. Laser classification Class 1 laser product Laser product compliance This laser product conforms to all applicable standards of 21 CFR 1040.10 at date of manufacture. FCC standards compliance Tested to comply with FCC standards for home or office use. CDRH compliance Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 (1 of 2) 34 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ANSI ONT safety guidelines Description Label text Operation conditions This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Canadian standard compliance (modular ONT) This Class A digital apparatus complies with Canadian ICES-003. Canadian standard compliance (outdoor ONT) This Class B digital apparatus complies with Canadian ICES-003. CE marking There are various CE symbols for CE compliance. (2 of 2) Figure 8 shows a sample safety label on the ONT equipment. Figure 8 Sample safety label on the ONT equipment Tested to Comply with FCC Standards FOR HOME OR OFFICE USE ® COMMUNICATION SERVICE EQUIPMENT US LISTED 27FY Type 3R Enclosure - Rainproof This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la class A est conforme a la norme NMB-003 du Canada CAUTION This Assembly Contains Electrostatic Sensitive Devices 18533 4.2 Safety standards compliance This section describes the ONT compliance with North American safety standards. Warning — Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Issue: 01 3FE-48631-AAAA-TCZZA 35 ANSI ONT safety guidelines 4.2.1 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide EMC, EMI, and ESD standards compliance The ONT equipment complies with the following requirements: • Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class A requirements for OLT equipment • GR-1089-CORE requirements, including: • Section 3 Electromagnetic Interference, Emissions Radiated and Conducted • Section 3 Immunity, Radiated and Conducted • Section 2 ESD Discharge Immunity: System Level Electrostatic Discharge and EFT Immunity: Electrically Fast Transients This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. • Consult the dealer or an experienced radio/TV technician for help. 4.2.2 Equipment safety standard compliance The ONT equipment complies with the requirements of UL60950-1, Outdoor ONTs to “Communication Service Equipment” (CSE) and Indoor ONTs to Information Technology Equipment (ITE). 36 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 4.2.3 ANSI ONT safety guidelines Environmental standards compliance The ONT equipment complies with the following standards: • GR-63-CORE (NEBS): requirements related to operating, storage, humidity, altitude, earthquake, office vibration, transportation and handling, fire resistance and spread, airborne contaminants, illumination, and acoustic noise GR-487-CORE: requirements related to rain, chemical, sand, and dust GR-487 R3-82: requirements related to condensation GR-3108: Requirements for Network Equipment in the Outside Plant (OSP) TP76200: Common Systems Equipment Interconnections Standards • • • • 4.2.4 Laser product standards compliance The ONT equipment complies with 21 CFR 1040.10 and CFR 1040.11, except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007” or to 21 CFR 1040.10 U.S. Center for Devices and Radiological Health (CDRH) of the Food and Drug Administration (FDA) Laser Notice 42 for ONTs containing Class 1 Laser modules certified by original manufactures. Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such as Nokia ONTs shall leave the following Laser Safety cautions with the end user. a) “Class 1 Laser Product” b) “Caution – Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.” Figure 9 shows a laser product label. Figure 9 Sample laser product label showing CDRH 21 CFR compliance 4P92 No User Serviceable Parts Inside. Refer All Servicing To Qualified Personnel. 12VDC 2.5A FiOS Enabled I.T.E To Order FiOS: 888 GET-FiOS Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to 2301 Sugar Bush Rd. or visit Verizon.com For Service: 888 553-1555 Laser Notice No. 50, dated June 24, 2007. Raleigh, NC 27612 22813 Issue: 01 3FE-48631-AAAA-TCZZA 37 ANSI ONT safety guidelines 4.2.5 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Resistibility requirements compliance The ONT equipment complies with the requirements of ITU Recommendation K.21 for resistibility of telecommunication equipment installed in customer premises to overvoltage and overcurrents. 4.3 Laser safety guidelines Only qualified service personnel who are extremely familiar with laser radiation hazards should install or remove the fiber optic cables and units in this system. Observe the following warnings when you perform installation, operations, and maintenance tasks on the ONT equipment. Danger — There may be invisible laser radiation at the fiber optic cable when the cable is removed from the connector. Avoid direct exposure to beam. Observe the following danger for a laser hazard. Eyes can be damaged when they are exposed to a laser beam. Take necessary precautions before you plug in the optical modules. Danger — Possibility of equipment damage. Risk of eye damage by laser radiation. Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such as Nokia ONTs shall leave the following Laser Safety cautions with the end user. a) “Class 1 Laser Product” b) “Caution – Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.” 4.3.1 Laser warning labels The following figures show sample labels related to laser product, classification and warning. Figure 10 shows a laser product label. 38 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 10 ANSI ONT safety guidelines Laser product label 18455 Figure 11 shows a laser classification label. Laser classification labels may be provided in other languages. Figure 11 Laser classification label CLASS 1 LASER PRODUCT PRODUCTO LASER CLASE 1 CLASE 1 DEL LASER LASER CLASSE 1 18992 Figure 12 shows a laser warning label and an explanatory label for laser products. Explanatory labels may be provided in other languages. The explanatory label provides the following information: • a warning that calls attention to the invisible laser radiation • an instruction against staring into the beam or viewing directly with optical instruments • wavelength • normal output power • maximum output power Issue: 01 3FE-48631-AAAA-TCZZA 39 ANSI ONT safety guidelines Figure 12 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Laser warning labels INVISIBLE LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS Wavelength(s): xxxx nm Normal output power: xx m W Max output power: yyy m W Laser Warning Label Laser Warning Label CLASS 1 LASER PRODUCT RAYONNEMENT LASER CLASSE 1 RAYONNEMENT LASER INVISIBLE EVITER TOUTE EXPOSITION AU FAISCEAU NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE CLASE 1 DEL LASER RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM. Laser Warning Label 18993 4.3.2 Laser classification The ONT is classified as a Class 1 laser product based on its transmit optical output. For Class 1 laser products, lasers are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Figure 13 shows a sample laser product safety label on the ONT equipment. 40 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 13 ANSI ONT safety guidelines Sample laser product safety label on the ONT equipment Model: MFG: MONTH: XX YEAR: XXXX ICS: XX MRev: XX 3FE55851ABAA MAC:XXXXXXXXXXXX SN:ALCLXXXXXXXX I.T.E FCC ID: XXXXXXXXXXX 12VDC 3A ASSEMBLED IN CHINA 2301 Sugar Bush Rd. Raleigh, NC 27612 CLASS 1 LASER PRODUCT PRODUIT LASER DE CLASSE 1 Intertek 4006119 This device complies with Part 15 of the FCC Rule. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including intereference that may cause undesired operation. DANGER - Invisible Laser radiation when open. AVOID DIRECT EXPOSURE TO BEAM. DANGER - Rayonnement Laser invisible lorsqu’elle est ouverte. Evitee l’expostion direct au faisceau. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 dated June 24, 2007 18532 4.3.3 Transmit optical output The maximum transmit optical output of an ONT is +5 dBm. 4.3.4 Normal laser operation In normal operation, fiber cable laser radiation is always off until it receives signal from the line terminal card. Operating personnel must observe the instructions on the laser explanatory label before plugging in the optical module. Danger — Risk of eye damage by laser radiation. 4.3.5 Location class Use cable supports and guides to protect the receptacles from strain. Issue: 01 3FE-48631-AAAA-TCZZA 41 ANSI ONT safety guidelines 4.4 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Electrical safety guidelines This section provides the electrical safety guidelines for the ONT equipment. Note — The ONTs comply with the U.S. National Electrical Code. However, local electrical authorities have jurisdiction when there are differences between the local and U.S. standards. 4.4.1 Power supplies The use of any non-Nokia approved power supplies or power adapters is not supported or endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use greatly increases the danger of damage to equipment or property. 4.4.2 Cabling The following are the guidelines regarding cables used for the ONT equipment: • Use only cables approved by the relevant national electrical code. • Use cables suitable for outdoor use for outdoor installation of ONTs. • The ONTs have been evaluated for use with external POTS wiring without primary protection that may not exceed 140 ft (43 m) in reach. However, the power cable must not exceed 100 ft (31 m). 4.4.3 Protective earth Earthing and bonding of the ONTs must comply with the requirements of NEC article 250 or local electrical codes. 4.5 ESD safety guidelines The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD instructions when they handle the ONT equipment. Caution — This equipment is ESD sensitive. Proper ESD protections should be used when entering the TELCO Access portion of the ONT. 42 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide ANSI ONT safety guidelines During installation and maintenance, service personnel must wear wrist straps to prevent damage caused by ESD. Nokia recommends that you prepare the site before you install the ONT equipment. In addition, you must control relative humidity, use static dissipating material for furniture or flooring, and restrict the use of air conditioning. 4.6 Environmental requirements See the ONT technical specification documentation for temperature ranges for ONTs. During operation in the supported temperature range, condensation inside the ONT caused by humidity is not an issue. To avoid condensation caused by rapid changes in temperature and humidity, Nokia recommends: • The door of the ONT not be opened until temperature inside and outside the enclosure has stabilized. • If the door of the ONT must be opened after a rapid change in temperature or humidity, use a dry cloth to wipe down the metal interior to prevent the risk of condensation. • When high humidity is present, installation of a cover or tent over the ONT helps prevent condensation when the door is opened. Issue: 01 3FE-48631-AAAA-TCZZA 43 ANSI ONT safety guidelines 44 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A unit data sheet 5 XS-240W-A and XS-250WX-A unit data sheet 5.1 XS-240W-A and XS-250WX-A part numbers and identification 5.2 XS-240W-A and XS-250WX-A general description 5.3 XS-240W-A and XS-250WX-A software and installation feature support 5.4 XS-240W-A and XS-250WX-A interfaces and interface capacity 5.5 XS-240W-A and XS-250WX-A LEDs 5.6 XS-240W-A and XS-250WX-A detailed specifications 5.7 XS-240W-A and XS-250WX-A GEM ports and T-CONTs 5.8 XS-240W-A and XS-250WX-A functional blocks 5.9 XS-240W-A and XS-250WX-A standards compliance 5.10 XS-240W-A and XS-250WX-A special considerations 5.1 XS-240W-A and XS-250WX-A part numbers and identification Table 3 provides part numbers and identification information for the XS-240W-A indoor ONT. Table 3 Identification of XS-240W-A indoor ONTs Ordering kit part number (1) Provisioning number Description CLEI CPR ECI/ Bar code 3FE 48631 AA 3FE 48631 AA XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. — — — ONT only North American Region (NAR) This ONT also has 2 USB 3.0 ports. (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 45 XS-240W-A and XS-250WX-A unit data sheet 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Ordering kit part number (1) Provisioning number Description CLEI CPR ECI/ Bar code 3FE 48631 AC 3FE 48631 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. — — — — — — — — — — — — ONT only Europe, the Middle East, and Africa region (EMEA) 3FE 48626 AA This ONT also has 2 USB 3.0 ports. 3FE 48631 AA XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin US power adapter. Also includes the power supply described in Table 5 and the wall mounting bracket (3FE 46917 AA) shown in Figure 14. 3FE 48626 BA 3FE 48631 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin EU (European) power adapter. Also includes the power supply described in Table 5 and the wall mounting bracket (3FE 46917 AA) shown in Figure 14. 3FE 48626 CA 3FE 48631 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin UK (British) power adapter. Also includes the power supply described in Table 5 and the wall mounting bracket (3FE 46917 AA) shown in Figure 14. (2 of 2) Notes (1) These kits will be available in a future release. Table 4 provides part numbers and identification information for the XS-250WX-A indoor ONT. Table 4 Identification of XS-250WX-A indoor ONTs Ordering kit part number (1) Provisioning number Description CLEI CPR ECI/ Bar code 3FE 48307 AA 3FE 48307 AA XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. — — — ONT only North American Region (NAR) This ONT also has 2 USB 3.0 ports. (1 of 2) 46 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A unit data sheet Ordering kit part number (1) Provisioning number Description CLEI CPR ECI/ Bar code 3FE 48307 AC 3FE 48307 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. — — — — — — — — — — — — ONT only Europe, the Middle East, and Africa region (EMEA) 3FE 48439 AA This ONT also has 2 USB 3.0 ports. 3FE 48307 AA XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin US power adapter. Also includes the power supply described in Table 5. 3FE 48439 BA 3FE 48307 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin EU (European) power adapter. Also includes the power supply described in Table 5. 3FE 48439 CA 3FE 48307 AC XGSPON HGU with 2 POTS ports, 4 10/100/1000 Base-T Ethernet interfaces, 1 XGE UNI port, and dual band 802.11n 3x3 and 802.11ac 4x4 WiFi radio with on/off switch. This ONT also has 2 USB 3.0 ports. Includes a 3-pin UK (British) power adapter. Also includes the power supply described in Table 5. (2 of 2) Notes (1) These kits will be available in Release 5.7.01. Table 5 provides power supply ordering information about the XS-240W-A and XS-250WX-A ONT. For more information on power supplies, see the 7368 ISAM ONT Power Supply and UPS Guide. Issue: 01 3FE-48631-AAAA-TCZZA 47 XS-240W-A and XS-250WX-A unit data sheet Table 5 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A power supply Power/UPS model Power UPS and cabling part number information Customer category or country compliance tested for (1) Notes Delta power adapter, ADP-66CR BC Part number: 1AF29813 AA AC/DC 12V, 66W, 5.5A power, 6-pin Molex DC connector (AC power cable not included) • ANSI municipality United States, Canada AC cable variants: • • • • 1AB076760010 (UK, Ireland, Middle East) 1AB076760071 (Europe) 1AB076760009 (Australia, New Zealand, and China) 1AB076760072 (UK, South Africa, and Middle East) 1AB076760073 (ANSI) Common European Union countries Note (1) The list of detailed tests (for example, GR-1089i3 (ESD, EFT, RDE, CDE, RDI, and CDI), GR-1089i4 (LightningAC) and marks (for example, FCC Class B, UL, CE Mark Class B, and K.21) are available from your Nokia technical support representative. Table 6 provides a summary of the similarities and differences between the XS-240W-A and the XS-250WX-A ONTs and their variants. Table 6 XS-240W-A and XS-250WX-A comparison Feature XS-240W-A XS-250WX-A PON uplink XGSPON XGSPON 10G UNI port N/A 1 x 10G UNI port Optics Integrated XGSPON optics on board Integrated XGSPON optics on board LEDs No 10G LED All LEDs ANSI (NAR) variant • • • • ETSI (EMEA) variant 5.2 ETL/FCC with DFS / WiFi Alliance EC/WiFi Alliance ETL/FCC with DFS / WiFi Alliance EC/WiFi Alliance XS-240W-A and XS-250WX-A general description XS-240W-A and XS-250WX-A ONTs are designed to cater to business and residential customer requirements. These ONTs offer data and video services to the subscriber. 48 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A unit data sheet XS-240W-A and XS-250WX-A indoor ONTs provide the subscriber interface for the network by terminating the PON interface and converting it to user interfaces that directly connect to subscriber devices. The ONT is compatible with all existing subscriber equipment, including analog phones with both tone and rotary dial capabilities, cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and Type III). XS-240W-A and XS-250WX-A ONTs feature an XGSPON link. The XS-250WX-A also provides one 10GE UNI port. Both ONTs provide two POTS ports and four Ethernet interfaces. The ONTs also feature a UPS power supply connection, on/off and reset buttons, and two USB 3.0 ports. On/off buttons are included for WPS, LEDs, and WLAN. XS-240W-A and XS-250WX-A ONTs can be placed on a flat surface, such as a desk or shelf, or in the stand provided with the ONT kit. They can also be wall mounted using the mounting bracket (3FE 46917 AA), as shown in Figure 14. Figure 14 XS-240W-A or XS-250WX-A in wall mounting bracket 28188 Figure 15 shows the connection for the XS-240W-A ONT. Issue: 01 3FE-48631-AAAA-TCZZA 49 XS-240W-A and XS-250WX-A unit data sheet Figure 15 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A ONT connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) USB 3.0 UPS power (2) supply Ethernet RJ-45 (4) 28054 Figure 16 shows the connection for the XS-250WX-A ONT. Figure 16 XS-250WX-A ONT connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 LAN 10G USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) Ethernet RJ-45 (4) 10 G USB 3.0 UPS power connection (2) supply 28051 XS-240W-A and XS-250WX-A indoor ONTs provide the following functions: • 10 Gbps interface supports 100M/1G/2.5G/5G/10Gbps auto negotiation • • • • • • • • • • • 50 (XS-250WX-A only) Four RJ-45 10/100/1000 Ethernet port with auto negotiation and MDI/MDIX auto sensing Two POTS ports for carrier grade voice services Two USB 3.0 ports, accessible to all LAN devices Triple-Play services, including voice, video and high speed Internet access Traffic classification and QoS capability Support for fax services Built-in layer 2 switch; Line Rate L2 traffic 512M RAM and 256M Flash IP video distribution Optics that support received signal strength indication (RSSI) Concurrent 802.11n 3x3 MIMO in 2.4GHz and 802.11ac 4x4 MIMO in 5GHz 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 5.2.1 XS-240W-A and XS-250WX-A unit data sheet WLAN on/off push button WPS on/off button 64/128 WEP encryption WPA, WPA-PSK/TKIP WPA2, WPA2-PSK/AES VLAN tagging/detagging and marking/remarking of IEEE 802.1p per Ethernet port. Dying gasp support SIP voice support Multiple voice Code DTMF dialing Echo cancellation (G.168) Fax mode configuration (T.30/T.38) Caller ID, call waiting, call hold, 3-way calling, call transfer, message waiting Forward Error Correction (FEC) Frame Check Sequence (FCS) error counter support for multiple SSIDs (private and public instances); contact your Nokia representative for further details. Routed mode per LAN port Ethernet-based Point-to-Point (PPPoE) DHCP client/server DNS server/client DDNS Port forwarding Network Address Translation (NAT) Network Address Port Translation (NAPT) UPnP IGD2.0 support ALG DMZ IGMP snooping and proxy (v2/v3) Traffic classification and QoS capability OMCI, TR-069, and Web GUI management support Performance monitoring and alarm reporting Remote software image downloading and activation IP/MAC/URL filter Multi-level firewall and ACL TR69 authentication using TLS and CA certificates XS-240W-A and XS-250WX-A ONTs support TLS, as well as ACS authentication using SHA-256 pre-installed certificates. Issue: 01 3FE-48631-AAAA-TCZZA 51 XS-240W-A and XS-250WX-A unit data sheet 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide If the URL is set to the https://... format, by default, the connection will use TLS without authentication mode. The ONT can also authenticate the ACS using a pre-installed CA certificate. 5.3 XS-240W-A and XS-250WX-A software and installation feature support For information on installing or replacing the XS-240W-A and XS-250WX-A see: • Install an XS-240W-A or XS-250WX-A indoor ONT • Replace an XS-240W-A or XS-250WX-A indoor ONT For information on the following topics, see the 7368 ISAM ONT Product Overview Guide: • • • • • • • • ONT and MDU general descriptions of features and functions Ethernet interface specifications POTS interface specifications RSSI specifications Wi-Fi specifications ONT optical budget SLID entry via Ethernet port ONT management using an ONT interface 5.4 XS-240W-A and XS-250WX-A interfaces and interface capacity Table 7 describes the supported interfaces and interface capacity for XS-240W-A and XS-250WX-A indoor ONTs. Table 7 XS-240W-A and XS-250WX-A indoor ONT interface connection capacity ONT type and model Maximum capacity POTS 10/ 100/ 1000 BASE-T RF video (CATV) MoCA 10G UNI port GPON SC/APC XS-240W-A(1) — — — XS-250WX-A (1) — — Note (1) 52 The XS-240W-A and XS-250WX-A ONTs provide Wi-Fi service that is enabled and disabled using a Wi-Fi on/off switch. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 5.4.1 XS-240W-A and XS-250WX-A unit data sheet XS-240W-A and XS-250WX-A connections and components Figures 15 and 16 show the physical connections for XS-240W-A and XS-250WX-A indoor ONTs, Table 8 describes the physical connections for XS-240W-A and XS-250WX-A indoor ONTs. Table 8 XS-240W-A and XS-250WX-A indoor ONT physical connections Connection (1) Description On/Off button This button turns the ONT on or off. WPS button The Wi-Fi Protected Setup button enables WPS2.4G and WPS5G. This button enables and disables WLAN data encryption. LED button This button turns the LEDs on or off. WLAN button Wi-Fi service is compliant with IEEE 802.11 standards and is enabled and disabled using the WLAN button. Reset button Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the Reset button for 10 seconds resets the ONT to the factory defaults. POTS ports This connection is provided through RJ-11 ports. Up to two POTS connections are supported.The POTS ports support voice services. Ethernet ports This connection is provided through Ethernet RJ-45 connectors. Up to four 10/100/1000 Base-T Ethernet interfaces are supported.The Ethernet ports can support both data and in-band video services on all four interfaces. 10GE port The 10GE link is provided through an APC optical connector. One 10GE connection is supported. (XS-250WX-A only) USB ports This connection is provided through 2 USB 3.0 ports. The ONT supports external USB hard drives that can be made accessible to all LAN devices. The following rates apply to the USB 3.0 ports: Rate current: 900mA Maximum continuous current: 1.5A Typical short-circuit current: 2.3A • • • UPS power supply This connection supports the UPS power adapter described in Table 5. Note (1) 5.5 The primary path for the earth ground for these ONTs is provided by the 12V Return signal in the power connector. XS-240W-A and XS-250WX-A LEDs Figure 17 shows the XS-250WX-A indoor ONT LEDs. Issue: 01 3FE-48631-AAAA-TCZZA 53 XS-240W-A and XS-250WX-A unit data sheet Figure 17 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-250WX-A indoor ONT LEDs Power PON Authorization Battery POWER BATTERY Link PON LINK POTS (2) Internet AUTH INTERNET TEL 1 TEL 2 5G Wireless WPS VOIP VOIP WPS 2.4G 10G link Ethernet (4) 2.4G Wireless 5G LAN 1 LAN 2 LAN 3 LAN 4 LAN 10G 28052 Note — The XS-240W-A model does not feature a 10G UNI port and therefore does not have a LED for a 10G link. Table 9 provides LED descriptions for XS-240W-A and XS-250WX-A indoor ONTs. Table 9 XS-240W-A and XS-250WX-A indoor ONT LEDs Indicator LED color and behavior LED behavior description Power Green solid Power on Off Power off Green solid Device is operating on AC power Red Device is operating on battery power Off Battery alarm Battery PON Link Auth Green solid GPON link between ONT and OLT is operating normally Green flashing Device is attempting to link Off GPON link is down or no link connected Green solid Link between the device and the OLT is operating normally Off Link is down or not connected Green solid ONT is authorized Green flashing ONT is process of ranging or synchronizing on OMCI Off ONT is not authorized (1 of 2) 54 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A unit data sheet Indicator LED color and behavior LED behavior description INTERNET Green solid HSI WAN is connected: a) the device has an IP address assigned from IPCP, DHCP, or static, and no traffic has been detected; b) the session is dropped due to idle timeout but the PON link is still present. Green flashing TEL 1 to 2 VOIP PPPoE or DHCP connection in progress Off HSI WAN is not connected: a) there is no physical interface connection; b) the device is in bridged mode without an assigned IP address; c) the session has been dropped for reasons other than idle timeout. Green solid Phone is off hook Green flashing Phone is in ‘call in’ or ‘talking’ condition Off Phone is on hook Green solid VOIP service is built up and can provide service Off VOIP service is not built up or out of service WPS Green solid WiFi protected setup link is up (negotiation and auto-configuration successful) 2.4G and 5G Green flashing WiFi protected setup link activity (negotiation and auto-configuration ongoing) Off WiFi protected setup link down or no link connected (negotiation has not started or has failed) Green solid WLAN link is enabled Green flashing Traffic is passing via WLAN link Off WLAN link is disabled Green solid WLAN link is enabled Green flashing Traffic is passing via WLAN link Off WLAN link is disabled Green solid Ethernet is linked Green flashing LAN activity is present (in either direction) Off ONT power is off or Ethernet is not connected 10G Green solid 10G link is operating normally (XS-250WX-A only) Green flashing 10G link activity is present (in either direction) Off 10G link is not connected WLAN 2.4G WLAN 5G LAN 1 to 4 (2 of 2) 5.6 XS-240W-A and XS-250WX-A detailed specifications Table 10 lists the physical specifications for XS-240W-A and XS-250WX-A indoor ONTs. Table 10 XS-240W-A and XS-250WX-A indoor ONT physical specifications Description Specification Length 11.4 in. (290.3 mm) (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 55 XS-240W-A and XS-250WX-A unit data sheet 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Description Specification Width 7.5 in. (190.3 mm) Height 3.0 in. (76.6 mm) Weight [within ± 0.5 lb (0.23 kg)] 2.7 lb (1.24 kg) (2 of 2) Table 11 lists the power consumption specifications for XS-240W-A and XS-250WX-A indoor ONT. Table 11 XS-240W-A and XS-250WX-A indoor ONT power consumption specifications Mnemonic Maximum power (Not to exceed) Condition Minimum power Condition XS-240W-A 43 W 7.62 W XS-250WX-A 46 W 2 POTS off-hook, 4 10/100/1000 Base-T Ethernet, Wi-Fi operational 2 POTS on-hook, other interfaces/services not provisioned 10.4 W Table 12 lists the environmental specifications for XS-240W-A and XS-250WX-A indoor ONT. Table 12 XS-240W-A and XS-250WX-A indoor ONT environmental specifications Mounting method Temperature range and humidity Altitude On desk or wall mounted Operating: 23°F to 104°F (-5°C to 40°C) ambient temperature Contact your Nokia technical support representative for more information 5% to 93% relative humidity, non-condensing at 40°C 5.7 XS-240W-A and XS-250WX-A GEM ports and T-CONTs Table 13 lists the maximum number of supported T-CONTs and GEM ports. 56 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 13 5.8 XS-240W-A and XS-250WX-A unit data sheet XS-240W-A and XS-250WX-A indoor ONT capacity for GEM ports and T-CONTs XS-240W-A and XS-250WX-A ONT Maximum Notes GEM ports per indoor or outdoor ONT 124 124 are present; 122 are available, and 2 are reserved for multicast and debugging T-CONTs per indoor or outdoor ONT 32 32 are present; 31 are available, and 1 is reserved for OMCI XS-240W-A and XS-250WX-A functional blocks XS-240W-A and XS-250WX-A indoor ONTs are single-residence ONTs that support Wireless (Wi-Fi) service. Wi-Fi service on these ONTs is compliant with the IEEE 802.11 standard and enabled or disabled using a WLAN button. In addition to the Wi-Fi service, these ONTs transmit Ethernet packets to four RJ-45 Ethernet ports and voice traffic to two RJ-11 POTS ports. These ONTs also feature XGPON1 fiber optic, USB, and power connectors. Figure 18 shows the functional blocks for the XS-240W-A ONT Issue: 01 3FE-48631-AAAA-TCZZA 57 XS-240W-A and XS-250WX-A unit data sheet Figure 18 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Functional blocks for XS-240W-A ONT 12V NAND Flash DDR3 PBI 1x4 Header DDR3 Conn LEDs Power Regulators SFP+ 1.0V UART JTAG GPIO xPON USB USB 3.0 port USB USB 3.0 port SoC GE PHY PCM SLAC+ SLIC RJ-11 RJ-11 5V 3.3V 2.5V GE PHY GE PHY GE PHY MDI MDI MDI MDI PCIe1 PCIe0 GE Magnetics GE Magnetics GE Magnetics GE Magnetics 802.11ac 4x4 802.11n 3x3 RJ-45 RJ-45 RJ-45 RJ-45 Antenna External Antenna External 28056 Figure 19 shows the functional blocks for the XS-250WX-A ONT. 58 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 19 XS-240W-A and XS-250WX-A unit data sheet Functional blocks for XS-250WX-A ONT 12V NAND Flash PBI DDR3 DDR3 1x4 Header UART Conn LEDs Power Regulators SFP+ 1.0V JTAG GPIO xPON USB USB 3.0 port USB USB 3.0 port SoC GE PHY PCM MDI GE PHY MDI 5V 3.3V 2.5V GE PHY MDI GE PHY MDI XFI PCIe1 PCIe0 10G Base-T XFI PHY SLAC+ SLIC GE Magnetics GE Magnetics GE Magnetics GE Magnetics MDI 802.11ac 4x4 802.11n 3x3 Antenna External Antenna External 10G Magnetics RJ-11 RJ-11 RJ-45 RJ-45 RJ-45 RJ-45 RJ-45 Optional 28053 ONT SoC technology serves as the main hardware block for these ONTs; see Figure 20. Issue: 01 3FE-48631-AAAA-TCZZA 59 XS-240W-A and XS-250WX-A unit data sheet Figure 20 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A ONT SoC hardware block POTS ports Control processor SoC DSP SoC Bridge Ethernet MACs GPON MAC Ethernet ports GPON 19421 ONT SoC technology consists of five key elements: • GPON MAC • • • • 60 The Gigabit Passive Optical Network Media Access Control (GPON MAC) element on the SoC terminates the GPON interface using an optical diplexer. This interface supports GPON as described in G.984.3 (GPON TC Layer) ITU specification. Ethernet MAC The SoC provides up to four GE MACs. DSP interface The Digital Signal Processor (DSP) provides voice processing for 2 POTS lines with 3-way calling. The DSP has a dedicated 64 kbyte instruction cache and shares a 32 kbyte data cache with the Control Processor. It provides up to 4 network processor cores, each at 800MHz. Control Processor The Control Processor features an integral memory management unit that supports a dedicated 64 kbyte instruction cache and shares a single 32 kbyte data cache with the DSP. The Control Processor and DSP also include a single channel Data Management Application (DMA) controller with a 4 kbyte read ahead low-latency Dynamic Random Access Memory (DRAM) access port. Switch matrix The Switch matrix provides an integrated data channel between the four GE MACs, the GPON MAC, the DSP, the control processor, and the other integrated elements such as flash memory, DRAM, and the local bus controller. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A unit data sheet These ONTs can also interact with additional hardware components to support functionality not provided by the SoC technology. 5.9 XS-240W-A and XS-250WX-A standards compliance XS-240W-A and XS-250WX-A indoor ONTs are compliant with the following standards: • • • • • • • • • • • • • • • • • • • • • • • • 5.9.1 AINSI/FCC/UL CE marking China/CCC (hardware only) EN 300-328 for 2.4GHz bands EN 301-489 for EUT with WiFi EN 301-893 for 5GHz bands ETL ETSI/CE/CB G.711 support for FAX and modem connection G.984 support GPON interface (framing) G.984.2 support for Amd1, class B+ G.984.3 support for activation and password functions G.984.3 support for AES with operator enable/disable on per port-ID level G.984.3 support for FEC in both upstream and downstream directions G.984.3 support for multicast using a single GEM Port-ID for all video traffic G984.4 and G.983.2 support for ONT management and provisioning G987.x support for XGPON TC layer IECEE CB certification IEEE 801.11 ac/n (Wi-Fi) IEEE 802.1p QoS IEEE 802.1q VLANs IEEE 802.3x flow control IEEE 802.3az, 802.3u, 802.3z ITU-T G.9807.1 support for XSPON TC layer Responsible party Table 14 lists the party in the US responsible for this ONT. Issue: 01 3FE-48631-AAAA-TCZZA 61 XS-240W-A and XS-250WX-A unit data sheet Table 14 5.9.2 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Responsible party contact information Legal Company name Nokia USA Inc. Address 2301 SUGAR BUSH RD. STE 300, RALEIGH,NC 27612 Phone, Fax +1 919 850 6127 Energy-related products standby and off modes compliance Hereby, Nokia declares that the XS-240W-A and XS-250WX-A ONTs are in compliance with the essential requirements and other relevant provisions of Directive 2009/125/EC together with Commission Regulation (EC) No 1275/2008 and Commission Regulation (EC) No 801/2013. The XS-240W-A and XS-250WX-A ONTS qualify as equipment with high network availability (HiNA) functionality. Since the main purpose of XS-240W-A and XS-250WX-A ONTs is to provide network functionality with HiNA 7 days /24 hours, the modes Off/Standby, Power Management, and Networked Standby are inappropriate. For information about the type and number of network ports, see “XS-240W-A and XS-250WX-A interfaces and interface capacity” in this chapter. For information about power consumption, see “XS-240W-A and XS-250WX-A detailed specifications” in this chapter. 5.9.3 FCC statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 62 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 5.9.4 XS-240W-A and XS-250WX-A unit data sheet FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Caution — Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 5.10 XS-240W-A and XS-250WX-A special considerations XS-240W-A and XS-250WX-A are package P ONTs. 5.10.1 Wi-Fi service XS-240W-A and XS-250WX-A indoor ONTs feature Wi-Fi service as well as voice and data services. Wi-Fi is a wireless networking technology that uses radio waves to provide wireless HSI and network connections. This ONT complies with the IEEE 802.11 standards, which the Wi-Fi Alliance defines as the basis for Wi-Fi technology. 5.10.1.1 Wi-Fi physical features XS-240W-A and XS-250WX-A indoor ONTs have the following physical features that assist in providing Wi-Fi service: • 7 internal antennae: 3 for 2.4G and 4 for 5G • WLAN button for enabling and disabling Wi-Fi service • one Wi-Fi Protected Setup (WPS) push button (for 2.4G and 5G) for adding WPS-enabled wireless devices Issue: 01 3FE-48631-AAAA-TCZZA 63 XS-240W-A and XS-250WX-A unit data sheet 5.10.1.2 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Wi-Fi standards and certifications The Wi-Fi service on XS-240W-A and XS-250WX-A indoor ONTs supports the following IEEE standards and Wi-Fi Alliance certifications: • certified for IEEE 802.11ac/b/g/n standards • WPA support including WPA-PSK • certified for WPA2-Personal and WPA2-Enterprise 5.10.1.3 Wi-Fi GUI features XS-240W-A and XS-250WX-A indoor ONTs have HTML-based Wi-Fi configuration GUIs. 5.10.2 XS-240W-A and XS-250WX-A ONT considerations and limitations Table 15 lists the considerations and limitations for Package P XS-240W-A and XS-250WX-A ONTs. Table 15 XS-240W-A and XS-250WX-A ONT considerations and limitations Considerations and limitations Some voice features are configurable on a per ONT basis, including Call Waiting, Call Hold, 3-Way Calling, and Call Transfer. The following voice features / GSIP parameters are configurable on a per-Client/ per-ONT basis (not per-Subscriber): • • • • • • Enable Caller ID and Enable Caller Name ID Digitmap and the associated Interdigit and Critical timers and Enter key parameters Warmline timer is enabled per subscriber, but the warmline timer value is configured per ONT and must have a lower value than the Permanent time Miscellaneous timers: Permanent, Timed-release, Reanswer, Error-tone, and CW-alert timers Features / functions: Message waiting mode, WMWI refresh interval, DTMF volume level Service Codes for the following features: CCW, Call Hold and Warmline The following features are not supported in Release 5.6: port triggering, port mirroring, parental control (access restrictions), and policy-based forwarding (in IP routing and QoS configuration). This device is restricted to indoor use. 64 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Install an XS-240W-A or XS-250WX-A indoor ONT 6 Install an XS-240W-A or XS-250WX-A indoor ONT 6.1 Purpose 6.2 General 6.3 Prerequisites 6.4 Recommended tools 6.5 Safety information 6.6 Procedure 6.1 Purpose This chapter provides the steps to install an XS-240W-A or XS-250WX-A indoor ONT. 6.2 General The steps listed in this chapter describe mounting and cabling for XS-240W-A or XS-250WX-A indoor ONTs. 6.3 Prerequisites You need the following items before beginning the installation: • all required cables 6.4 Recommended tools You need the following tools for the installation: • • • • Issue: 01 #2 Phillips screwdriver 1/4 in. (6 mm) flat blade screwdriver wire strippers fiber optic splicing tools 3FE-48631-AAAA-TCZZA 65 Install an XS-240W-A or XS-250WX-A indoor ONT • • • • • 6.5 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide RJ-45 cable plug crimp tool voltmeter or multimeter optical power meter drill and drill bits paper clip Safety information Read the following safety information before installing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 — Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals. Use a voltmeter to measure for voltage before proceeding. Danger 3 — Always contact the local utility company before connecting the enclosure to the utilities. Warning — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT. Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit. 66 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Install an XS-240W-A or XS-250WX-A indoor ONT Note 1 — Observe the local and national laws and regulations that may be applicable to this installation. Note 2 — Observe the following: • The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC. • The indoor ONT must be installed by qualified service personnel. • Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use. • See the detailed specifications in the XS-240W-A and XS-250WX-A unit data sheet for the temperature ranges for these ONTs. 6.6 Procedure Use this procedure to install an XS-240W-A or XS-250WX-A indoor ONT. Place the indoor ONT unit: On the flat surface, such as a desk or shelf, or in the stand provided with the ONT kit; go to step 3. Note — The XS-240W-A or XS-250WX-A ONT cannot be stacked with another ONT or with other equipment. The ONT mounting requirements are: • • • Issue: 01 allow a minimum 100 mm clearance above the top cover allow a minimum 50 mm clearance from the side vents do not place any heat source directly above the top cover or below the bottom cover On a wall, go to step 2. Mount the ONT on a wall using the wall mounting bracket (3FE 46917 AA) shown in Figure 21. 3FE-48631-AAAA-TCZZA 67 Install an XS-240W-A or XS-250WX-A indoor ONT Figure 21 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-240W-A and XS-250WX-A wall mounting bracket 28187 Figure 22 shows the ONT mounted in the wall bracket. Be careful not to bend the cables. Figure 22 XS-240W-A and XS-250WX-A ONT in wall mounting bracket 28189 68 Review the connection locations as shown in Figures 23 and 24. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Figure 23 Install an XS-240W-A or XS-250WX-A indoor ONT XS-240W-A ONT connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) USB 3.0 UPS power (2) supply Ethernet RJ-45 (4) 28054 Figure 24 XS-250WX-A connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 LAN 10G USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) Ethernet RJ-45 (4) USB 3.0 UPS power 10 G connection (2) supply 28051 Note — The 10 GE UNI port is only featured on the XS-250WX-A. Connect the Ethernet cables to the RJ-45 ports; see Figure 23 or 24 for the location of the RJ-45 ports. Route the POTS cables directly to the RJ-11 ports as per local practices. The POTS port to the left is labeled TEL1 for Line 1 while the port on the right is labeled TEL2 for Line 2, as shown in Figure 23 or 24. Issue: 01 3FE-48631-AAAA-TCZZA 69 Install an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide For the XS-250WX-A ONT, connect the fiber optic cable with APC adapter into the 10GE connector; see Figure 24 for the location of the 10GE connector. Danger — Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. Warning — Be careful to maintain a bend radius of no less than 1.5 in. (3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber. Note — Fiber cable preparation varies depending on the type and size of the inside or outside plant fiber cable being spliced to the SC/APC fiber optic pigtail cable. Install the power supply according to manufacturer specifications. Note — Observe the following: • Power up the ONT unit by using the power switch. If used, enable the Wi-Fi service: 10 70 Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of 12VDC, 3A. Locate the WLAN button on the ONT; see Figure 23 or 24 for location of the WLAN button. ii Press the WLAN button to change the status of the Wi-Fi service. If used, enable the WPS service. Locate the WPS buttons on the ONT; see Figure 23 or 24 for location of the WPS buttons for 2.4G and 5G Wi-Fi. ii Press the WPS buttons to change the status of the Wi-Fi Protected Service. 11 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. 12 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 13 If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide. 14 If necessary, reset the ONT. 15 Issue: 01 Install an XS-240W-A or XS-250WX-A indoor ONT Locate the Reset button on a XS-240W-A or XS-250WX-A indoor ONT as shown in Figure 23 or 24. ii Insert the end of a straightened paper clip or other narrow object into the hole in the Reset button to reset the ONT. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 71 Install an XS-240W-A or XS-250WX-A indoor ONT 72 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Replace an XS-240W-A or XS-250WX-A indoor ONT 7 Replace an XS-240W-A or XS-250WX-A indoor ONT 7.1 Purpose 7.2 General 7.3 Prerequisites 7.4 Recommended tools 7.5 Safety information 7.6 Procedure 7.1 Purpose This chapter provides the steps to replace XS-240W-A or XS-250WX-A indoor ONTs. 7.2 General The steps listed in this chapter describe mounting and cabling for XS-240W-A or XS-250WX-A indoor ONTs. 7.3 Prerequisites You need the following items before beginning the installation: • all required cables 7.4 Recommended tools You need the following tools for replacing the ONT: • • • • Issue: 01 #2 Phillips screwdriver 1/4 in. (6 mm) flat blade screwdriver wire strippers fiber optic splicing tools 3FE-48631-AAAA-TCZZA 73 Replace an XS-240W-A or XS-250WX-A indoor ONT • • • • 7.5 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide RJ-45 cable plug crimp tool voltmeter or multimeter optical power meter drill and drill bits Safety information Read the following safety information before replacing the unit. Danger 1 — Hazardous electrical voltages and currents can cause serious physical harm or death. Always use insulated tools and follow proper safety precautions when connecting or disconnecting power circuits. Danger 2 — Make sure all sources of power are turned off and have no live voltages present on feed lines or terminals. Use a voltmeter to measure for voltage before proceeding. Danger 3 — Always contact the local utility company before connecting the enclosure to the utilities. Warning — This equipment is ESD sensitive. Proper ESD protections should be used when removing the fiber access cover of the indoor ONT. Caution — Keep indoor ONTs out of direct sunlight. Prolonged exposure to direct sunlight can damage the unit. Note 1 — Observe the local and national laws and regulations that may be applicable to this installation. Note 2 — Observe the following: • The indoor ONT should be installed in accordance with the applicable requirements of the NEC or CEC. Local authorities and practices take precedent when there is conflict between the local standard and the NEC or CEC. • The indoor ONT must be installed by qualified service personnel. • Indoor ONTs must be installed with cables that are suitably rated and listed for indoor use. • See the detailed specifications in the XS-240W-A and XS-250WX-A unit data sheet for the ONT temperature ranges for these ONTs. 74 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 7.6 Replace an XS-240W-A or XS-250WX-A indoor ONT Procedure Use this procedure to replace an XS-240W-A or XS-250WX-A indoor ONT. Deactivate the ONT services at the P-OLT. If you are using the SLID feature, this step is not required. The ONT and the services can remain in service (IS). Use the RTRV-ONT command to verify the ONT status and th associated services. Record the serial number or the SLID of the ONT displayed in the command output. Example: RTRV-ONT::ONT-1-1-1-1-1; ii If the ONT is in service, place the ONT in OOS state. Example: ED-ONT::ONT-1-1-1-1-1; Figure 25 If used, disable the Wi-Fi service by pressing the WLAN button; see Figure 25 for 26 for the location of the WLAN button. XS-240W-A ONT connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) Ethernet RJ-45 (4) USB 3.0 UPS power (2) supply 28054 Issue: 01 3FE-48631-AAAA-TCZZA 75 Replace an XS-240W-A or XS-250WX-A indoor ONT Figure 26 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide XS-250WX-A ONT connections ON/OFF WPS LED WLAN RST TEL 1 TEL 2 LAN 1 LAN 2 LAN 3 LAN 4 LAN 10G USB 1 USB 2 UPS ON/OFF WPS on/off LEDs on/off Wireless on/off Reset POTS RJ-11 (2) Ethernet RJ-45 (4) 10 G USB 3.0 UPS power connection (2) supply 28051 Power down the unit by using the on/off power switch; see Figure 25 or 26 for the on/off switch. Note that the 10 GE UNI port is only featured on the XS-250WX-A. Disconnect the POTS, Ethernet, and power cables from the ONT; see Figure 25 or 26 for the connector locations on the XS-240W-A and XS-250WX-A indoor ONT. Unplug the fiber optic cable with APC connector from the ONT; see Figure 25 or 26 for the location of the fiber optic port. Danger — Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. Replace the ONT with a new unit. Connect the Ethernet cables directly to the RJ-45 ports; see Figure 25 or 26 for the location of the RJ-45 ports. Connect the POTS cables directly to the RJ-11 ports as per local practices; see Figure 25 or 26 for the location of the RJ-11 ports. The RJ-11 port to the left is labeled TEL1 for Line 1 while the port on the right is labeled TEL2 for Line 2. 76 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Replace an XS-240W-A or XS-250WX-A indoor ONT If required, have approved service personnel who are trained to work with optic fiber clean the fiber optic connection. See the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information about fiber optic handling, inspection, and cleaning. Danger — Fiber optic cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. 10 For the XS-250WX-A ONT, connect the fiber optic cable with APC adapter into the APC connector. Figure 26 shows the location of the fiber optic connector. Danger — Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly into fibers, connectors, or adapters. Warning — Be careful to maintain a bend radius of no less than 1.5 in. (3.8 cm) when connecting the fiber optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber. Note — Fiber cable preparation varies depending on the type and size of the inside or outside plant fiber cable being spliced to the SC/APC fiber optic pigtail cable. 11 Install the power supply according to manufacturer specifications. Note — Observe the following: • Issue: 01 Units must be powered by a Listed or CE approved and marked limited power source power supply with a minimum output rate of 12VDC, 3A. 12 Power up the unit by using the power on/off switch. 13 If used, enable the Wi-Fi service by pressing the WLAN button; see Figure 25 or 26 for the location of the WLAN button. 14 If used, enable the WPS service. Locate the WPS buttons on the ONT; see Figure 25 or 26 for location of the WPS buttons for 2.4G and 5G Wi-Fi. ii Press the WPS buttons to change the status of the Wi-Fi Protected Service. 3FE-48631-AAAA-TCZZA 77 Replace an XS-240W-A or XS-250WX-A indoor ONT 15 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information. Note — A new SLID or the old SLID may be used with the replacement ONT. If a new SLID is used, the new SLID must also be programmed at the P-OLT using TL1 or a network manager. If the old SLID is used, no changes need to be made at the P-OLT; see the operations and maintenance documentation for the OLT for more details. 16 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368 Hardware and Cabling Installation Guide. 17 Activate and test the services; see the 7368 Hardware and Cabling Installation Guide. 18 If necessary, reset the ONT. 19 78 Locate the Reset button on a XS-240W-A or XS-250WX-A indoor ONT as shown in Figure 25 or 26. ii Insert the end of a straightened paper clip or other narrow object into the hole in the Reset button to reset the ONT. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Configure an XS-240W-A or XS-250WX-A indoor ONT 8 Configure an XS-240W-A or XS-250WX-A indoor ONT 8.1 General 8.2 HGU mode GUI configuration 8.1 General Please refer to the configuration information provided with your OLT for the software configuration procedure for an XS-240W-A or XS-250WX-A ONT. For HTTP configuration procedures, please refer to the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide. 8.2 HGU mode GUI configuration Use the procedures below to use the web-based GUI for the XS-240W-A or XS-250WX-A in HGU mode. This mode is preset at delivery. A home gateway unit (HGU) is a home networking device, used as a gateway to connect devices in the home through fiber to the Internet. An HGU provides a variety of features for the home network including routing and firewall capability. By using the HGU, users can connect all smart equipment in their home, including personal computers, set-top boxes, mobile phones, and other consumer electronics devices, to the Internet. 8.2.1 Login Use the procedure below to login to the web-based GUI for the XS-240W-A or XS-250WX-A. Procedure 6 Login to web-based GUI Open a web browser and enter the IP address of the ONT in the address bar. The login window appears. The default gateway IP address is http://192.168.1.254. You can connect to this IP address using your web browser after connecting your PC to one of Ethernet ports of the ONT. The static IP address of your PC must be in the same 192.168.1.x subnet as the ONT. Issue: 01 3FE-48631-AAAA-TCZZA 79 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Enter your username and password in the Log in window, as shown in Figure 27. The default user name is AdminGPON. The default password for OPID ALCL is ALC#FGU. Figure 27 Web login window Caution — Pressing the Reset button for less than 10 seconds reboots the ONT; pressing the Reset button for 10 seconds resets the ONT to the factory defaults. Note — If you forget the current username and password, press the reset button for 5 s and the default values for the username and password will be recovered at startup. Click Login. The Device Information screen appears. Note — To help protect the security of your Internet connection, the application displays a pop-up reminder to change both the Wi-Fi password and the ONT password. To increase password security, use a minimum of 10 characters, consisting of a mix of numbers and upper and lower case letters. 8.2.2 STOP. This procedure is complete. Device and connection status XS-240W-A and XS-250WX-A ONTs support the retrieval of a variety of device and connection information, including: • device information • LAN status • WAN status 80 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide • • • • • Procedure 7 Configure an XS-240W-A or XS-250WX-A indoor ONT WAN status IPv6 Home networking information optics module status statistics voice information Device information retrieval Select Status > Device Information from the top-level menu in the 10G PON Gateway window, as shown in Figure 28. Figure 28 Device Information window Table 16 describes the fields in the Device Information window. Table 16 Device Information parameters Field Description Device Name Name on the ONT Vendor Name of the vendor Serial Number Serial number of the ONT Hardware version Hardware version of the ONT Boot version Boot version of the ONT Software version Software version of the ONT (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 81 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Chipset Chipset of the ONT Lot Number Production date of the ONT Device Running Time Amount of time the device has run since last reset in hours, minutes, and seconds (2 of 2) 82 Click Refresh to update the displayed information. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 8 Configure an XS-240W-A or XS-250WX-A indoor ONT LAN status retrieval Select Status > LAN Status from the top-level menu in the 10G PON Gateway window, as shown in Figure 29. Figure 29 LAN status window Table 17 describes the fields in the LAN status window. Table 17 LAN status parameters Field Description Wireless Information (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 83 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Wireless Status Indicates whether the wireless is on or off Wireless Channel Wireless channel number SSID Name Name of each SSID Wireless Encryption Status Encryption type used on the wireless connection Wireless Rx Packets Number of packets received on the wireless connection Wireless Tx Packets Number of packets transmitted on the wireless connection Wireless Rx Bytes Number of bytes received on the wireless connection Wireless Tx Bytes Number of bytes transmitted on the wireless connection Power Transmission (mW) Power of the wireless transmission, in mW Ethernet Information Ethernet Status Indicates whether the Ethernet connection is on or off Ethernet IP Address IP address of the Ethernet connection Ethernet Subnet Mask Subnet Mask of the Ethernet connection Ethernet MAC Address MAC address of the Ethernet connection Ethernet Rx Packets Number of packets received on the Ethernet connection Ethernet Tx Packets Number of packets transmitted on the Ethernet connection Ethernet Rx Bytes Number of bytes received on the Ethernet connection Ethernet Tx Bytes Number of bytes transmitted on the Ethernet connection LAN 1 to 4 and LAN 5 (10G) information This panel displays the following information for each LAN: status (up or down) duplex mode (full or auto) max bit rate errors received errors sent packets received packets sent bytes received bytes sent • • • • • • • • • (2 of 2) 84 Click Refresh to update the displayed information. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 9 Configure an XS-240W-A or XS-250WX-A indoor ONT WAN status retrieval Select Status > WAN Status from the top-level menu in the 10G PON Gateway window, as shown in Figure 30. Figure 30 WAN status window Table 18 describes the fields in the WAN status window. Table 18 WAN status parameters Field Description WAN connection list Drop-down menu listing all WAN connections. The connection shown is the connection for which WAN status will be shown. Connection Mode Connection mode of the WAN connection Enable/Disable Select this checkbox to enable the WAN connection VLAN VLAN ID WAN Link Status Whether the WAN link is up or down (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 85 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description IPv4 Address IPv4 address Netmask Netmask Gateway IPv4 gateway address Primary DNS Primary Domain Name Server Second DNS Secondary Domain Name Server PON Link Status Whether the PON link is up or down Tx Packets Number of packets transmitted on the WAN connection Rx Packets Number of packets received on the WAN connection Tx Dropped Number of packets dropped on the transmit WAN connection Rx Dropped Number of packets dropped on the receive WAN connection Err Packets Number of errored packets on the WAN connection (2 of 2) 86 Click Refresh to update the displayed information. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 10 Configure an XS-240W-A or XS-250WX-A indoor ONT WAN status IPv6 retrieval Select Status > WAN Status IPv6 from the top-level menu in the 10G PON Gateway window, as shown in Figure 31. Figure 31 WAN status IPv6 window Table 19 describes the fields in the WAN status IPv6 window. Table 19 WAN status IPv6 parameters Field Description WAN connection list Drop-down menu listing all WAN connections. The connection shown is the connection for which WAN status will be shown. Enable/Disable Select this checkbox to enable the WAN connection VLAN VLAN ID WAN Link Status Whether the WAN link is up or down IPv6 Address IPv6 address that identifies the device and its location IPv6 Prefix IPv6 Prefix IPv6 Gateway IPv6 Gateway address Primary DNS Primary Domain Name Server (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 87 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Second DNS Secondary Domain Name Server PON Link Status Whether the PON link is up or down Tx Packets Number of packets transmitted on the WAN connection Rx Packets Number of packets received on the WAN connection Tx Dropped Number of packets dropped on the transmit WAN connection Rx Dropped Number of packets dropped on the receive WAN connection Err Packets Number of errored packets on the WAN connection (2 of 2) 88 Click Refresh to update the displayed information. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 11 Configure an XS-240W-A or XS-250WX-A indoor ONT Home networking information retrieval Select Status > Home Networking from the top-level menu in the 10G PON Gateway window, as shown in Figure 32. Figure 32 Home networking information window Table 20 describes the fields in the Home networking window. Table 20 Home networking parameters Field Description Local Interface Ethernet Table displays the number of Ethernet connections and their settings Wireless Table displays the number of wireless connections and their settings Wireless Settings Network Name Name of the wireless network Access Point Address of the wireless access point Local Devices (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 89 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Table entry Each entry indicates the status (active or inactive), connection type, device name, IP address, hardware address, and IPv4 address allocation of each connected local device. (2 of 2) Click Delete to delete a particular local device connection. Click Refresh to update the displayed information. STOP. This procedure is complete. Procedure 12 Optics module status retrieval Select Status > Optics Module Status from the top-level menu in the 10G PON Gateway window, as shown in Figure 33. Figure 33 Optics module status window Table 21 describes the fields in the Optics module status window. 90 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 21 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT Optics module status parameters Field Description Laser Bias Current (ONT ANI-ONT-Side Optical Measurements) Laser bias current, measured in uA Optics Module Voltage (ONT ANI-ONT-Side Optical Measurements) Optics module voltage, measured in V Optics Module Temperature (ONT ANI-ONT-Side Optical Measurements) Optics module temperature, measured in C Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side Optical Measurements) Received optics signal level at 1490 nm, measured in dBm Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side Optical Measurements) Transmitted optics signal level at 1310 nm, measured in dBm Lower (ONT ANI-ONT-Side Optical Measurements-Optical Threshold) Lower optical threshold, measured in dBm Upper (ONT ANI-ONT-Side Optical Measurements-Optical Threshold) Upper optical threshold, measured in dBm Click Refresh to update the displayed information. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 91 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 13 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Statistics retrieval Select Status > Statistics from the top-level menu in the 10G PON Gateway window, as shown in Figure 34. Figure 34 Statistics window The Statistics window displays the statistical details for the WAN and each LAN line, such as the bytes, packets, and errors. 92 STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 14 Configure an XS-240W-A or XS-250WX-A indoor ONT Voice information retrieval Select Status > Voice Information from the top-level menu in the 10G PON Gateway window, as shown in Figure 35. Figure 35 Voice Information window Table 22 describes the fields in the Voice Information window. Table 22 Voice Information parameters Field Description Line Select the POTS line: 1 or 2 Line Status Status of the selected POTS line: Disabled: the line is disabled Up: the line is registered Registering: the line is registering Error: the line failed to register Softswitch(1) Phone number(1) Proxy IP address; blank if the line is not registered Phone number configured for the selected telephone line Register Status Registration status of the selected POTS port: registered or unregistered Register Error Code Error code for the unregistered POTS port User Agent User Agent: IP (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 93 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Register Error Reason Error reason for the unregistered POTS port (2 of 2) Note (1) This field is only visible at the adminGPON level; it is not visible at the userAdmin level. Click Refresh to update the displayed information. STOP. This procedure is complete. 8.2.3 Network configuration XS-240W-A and XS-250WX-A ONTs also support network configuration, including: • • • • • • • • • • • 94 LAN LAN IPv6 WAN WAN DHCP Wireless 2.4GHz Wireless 5GHz wireless scheduling IP Routing DNS TR-069 QoS 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 15 Configure an XS-240W-A or XS-250WX-A indoor ONT LAN networking configuration Select Network > LAN from the top-level menu in the 10G PON Gateway window, as shown in Figure 36. Figure 36 LAN network window Table 23 describes the fields in the LAN network window. Table 23 LAN network parameters Field Description All Ports to Bridge Mode Select this checkbox to set all ports to bridge mode (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 95 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Port Mode Port 1 - 4 and Port 5 (10G) Drop-down port mode for each port: Route mode or bridge mode IPv4 Address IP Address of the ONT Subnet Mask Subnet mask of the ONT DHCP enable Select this checkbox to enable DHCP DHCP Start IP Address Starting DHCP IP address DHCP End IP Address Ending DHCP IP address DHCP Lease Time DHCP lease time (in min) Primary DNS Primary DNS identifier Secondary DNS Secondary DNS identifier Static DHCP Entry MAC Address MAC address for the static DHCP Static DHCP Entry IPv4 Address IPv4 address for the static DHCP (2 of 2) Select the mode for each port. Click Save. Enter the DHCP configuration information. Click Save. Enter the Static DHCP information. Click Add. You can also use this panel to delete a Static DHCP MAC address or IPv4 address. 96 STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 16 Configure an XS-240W-A or XS-250WX-A indoor ONT LAN IPv6 networking configuration Select Network > LAN_IPv6 from the top-level menu in the 10G PON Gateway window, as shown in Figure 37. Figure 37 LAN IPv6 network window Table 24 describes the fields in the LAN IPv6 network window. Table 24 LAN IPv6 network parameters Field Description DNS Server Choose a DNS server from the drop-down menu. prefix config Choose a prefix config option from the drop-down menu, either WANConnection (prefix will be obtained from the WAN) or Static (enables you to enter the prefix). prefix This field appears if you selected the “Static” option for the “prefix config” field. Type a connection. Interface This field appears if you selected the Wan Connection option for the “prefix config” field. Choose a WAN connection interface from the drop-down menu. (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 97 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description DHCP Start IP Address Enter the starting DHCP IP address. DHCP End IP Address Enter the ending DHCP IP address. Whether the address info through DCHP Select this checkbox to enable address information retrieval through DHCP. Whether other info obtained through DHCP Select this checkbox to enable retrieval of other information through DHCP. Maximum interval for periodic RA messages Enter the maximum interval (in seconds) for periodic Router Advertisement messages. The interval range is from 4 to 1800. Minimum interval for periodic RA messages Enter the minimum interval (in seconds) for periodic Router Advertisement messages. The interval range is from 4 to 1800. (2 of 2) 98 Choose a DNS server, prefix config, and interface. Select or enter the DHCP configuration information. Enter the maximum and minimum intervals for RA messages. Click Save/Apply. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 17 Configure an XS-240W-A or XS-250WX-A indoor ONT WAN networking configuration Select Network > WAN from the top-level menu in the 10G PON Gateway window, as shown in Figure 38. Figure 38 WAN network window Table 25 describes the fields in the WAN network window. Table 25 WAN network parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu to set the connection parameters Connection Type Select a connection type: IPoE or PPPoE IP Mode Choose an IP mode from the drop-down menu: IPv4 or IPv6 Enable/Disable Select this checkbox to enable the WAN connection NAT Select this checkbox to enable NAT Service Select the checkboxes to enable service types for this connection Enable VLAN Select this checkbox to enable VLAN VLAN ID Enter the VLAN ID VLAN PRI Enter the VLAN PRI (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 99 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description WAN IP Mode Choose an IP mode from the drop-down menu Manual DNS Enter a DNS (2 of 2) Configure a specific WAN connection. Click Save. STOP. This procedure is complete. Procedure 18 WAN DHCP configuration Select Network > WAN DHCP from the top-level menu in the 10G PON Gateway window, as shown in Figure 39. Figure 39 WAN DHCP window Table 26 describes the fields in the WAN DHCP window. 100 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 26 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT WAN DHCP parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu DHCP Option 50 persistent Select this checkbox to enable DHCP Option 50 Enable DHCP Option 60 Select this checkbox to enable DHCP Option 60 (vendor class identifier) Vendor Class Identifier 60 Enter the identifier for the vendor class Enable DHCP Option 61 Select this checkbox to enable DHCP Option 61 (client identifier) Configure a WAN DHCP option. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 101 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 19 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide WiFi 2.4G networking configuration Select Network > Wireless 2.4GHz from the top-level menu in the 10G PON Gateway window, as shown in Figure 40. Figure 40 Wireless 2.4GHz network window Table 27 describes the fields in the Wireless 2.4GHz network window. Table 27 Wireless 2.4GHz network parameters Field Description Enable Select this checkbox to enable WiFi (1 of 2) 102 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Configure an XS-240W-A or XS-250WX-A indoor ONT Field Description Mode Choose a Wi-Fi mode from the drop-down menu: Bandwidth • • • • • auto (b/g/n) b/g Choose from: • • • 20 MHz 40 MHz 20/40 MHz Channel Choose a channel from the drop-down menu or choose Auto to have the channel automatically assigned Transmitting Power Choose a percentage for the transmitting power from the drop-down menu: • • • • Low (25%) Medium (50%) High (75%) Maximum (100%) WMM Select this checkbox to enable or disable wireless multi media Total MAX Users Enter the total number of MAX users SSID Select Choose the SSID from the drop-down menu SSID Name Enter the SSID name Enable SSID Enable or disable SSID from this drop-down menu SSID Broadcast Enable or disable SSID broadcast from this drop-down menu Port Mode Choose a port mode from the drop-down menu: MAX Users Encryption Mode WPA Version • • Route Bridge Enter the number of MAX users Choose an encryption mode from the drop-down menu: • • • • OPEN WEP WPA/WPA2 Personal WPA/WPA2 Enterprise (1)(2) Choose a WPA version from the drop-down menu: • • • WPA1 WPA2 WPA1/WPA2 WPA Encryption Mode Choose a WPA encryption mode from the drop-down menu: WPA Key Enter the WPA key Enable WPS Enable or disable WPS from this drop-down menu • • • TKIP AES TKIP/AES (2 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 103 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Notes (1) When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options are no longer available: WPA version, WPA encryption mode, WPA key, Enable WPS, WPS mode. (2) 104 When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options become available: Primary RADIUS server, port and password; Secondary RADIUS server, port, and password; RADIUS accounting port. Configure the wireless 2.4 GHz connection. If you have enabled and configured WPS, click WPS connect. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 20 Configure an XS-240W-A or XS-250WX-A indoor ONT Wireless 5GHz networking configuration Select Network > Wireless 5GHz from the top-level menu in the 10G PON Gateway window, as shown in Figure 41. Figure 41 Wireless 5GHz network window Table 28 describes the fields in the Wireless 5GHz network window. Table 28 Wireless 5GHz network parameters Field Description Enable Select this checkbox to enable WiFi (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 105 Configure an XS-240W-A or XS-250WX-A indoor ONT Field Description Bandwidth Choose from: • • • 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 20 MHz 40 MHz 80 MHz Channel Choose a channel from the drop-down menu or choose Auto to have the channel automatically assigned Transmitting Power Choose a percentage for the transmitting power from the drop-down menu: • • • • Low (20%) Medium (40%) High (60%) Maximum (100%) WMM Select this checkbox to enable or disable wireless multi media Enable MU-MIMO Choose Enable or disable MU-MIMO from this drop-down menu The default is Enable, which enables users and wireless terminals to communicate with each other. MU-MIMO may decrease Wi-Fi performance for clients who do not support it, in which case Nokia recommends that you choose Disable. Total MAX Users Enter the total number of MAX users DFS re-entry Select this checkbox to enable or disable DFS re-entry SSID Select Choose the SSID from the drop-down menu SSID Name Change the name of the selected SSID Enable SSID Choose Enable or disable SSID from this drop-down menu SSID Broadcast Choose Enable or disable SSID broadcast from this drop-down menu Port Mode Choose Route or Bridge from the drop-down menu MAX Users Enter the number of MAX users Encryption Mode Choose an encryption mode from the drop-down menu: OPEN WEP WPA/WPA2 Personal WPA/WPA2 Enterprise (1)(2) • • • • WPA Key Enter the WPA key Enable WPS Choose Enable or disable WPS from this drop-down menu (2 of 2) Notes (1) When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options are no longer available: WPA version, WPA encryption mode, WPA key, Enable WPS, WPS mode. (2) 106 When Encryption Mode is set to “WPA/WPA2 Enterprise”, the following options become available: Primary RADIUS server, port and password; Secondary RADIUS server, port, and password; RADIUS accounting port. Configure the wireless 5GHZ connection. If you have enabled and configured WPS, click WPS connect. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Click Save. STOP. This procedure is complete. Procedure 21 Wireless scheduling Select Network > Wireless Schedule from the top-level menu in the 10G PON Gateway window, as shown in Figure 42. Figure 42 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT Wireless Schedule network window Select the Schedule Function checkbox to turn the wireless signal off for the configured period. Select the Start, End, and Recurrence Pattern rules for turning the wireless signal off. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 107 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 22 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide IP Routing configuration Note that forwarding policy is not supported in Release 5.6. Select Network > IP Routing from the top-level menu in the 10G PON Gateway window, as shown in Figure 43. Figure 43 IP Routing network window Table 29 describes the fields in the IP Routing network window. Table 29 IP Routing network parameters Field Description Enable Routing Select this checkbox to enable routing Destination IP Address Enter the destination IP address Destination Netmask Enter the destination network mask Gateway Enter the gateway address (1 of 2) 108 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Configure an XS-240W-A or XS-250WX-A indoor ONT Field Description IPv4 Interface Choose a WAN connection previously created in the WAN network window from the drop-down menu (2 of 2) Enter the routing information. Click Add. STOP. This procedure is complete. Procedure 23 DNS configuration Select Network > DNS from the top-level menu in the 10G PON Gateway window, as shown in Figure 44. Figure 44 Issue: 01 DNS network window 3FE-48631-AAAA-TCZZA 109 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 30 describes the fields in the DNS network window. Table 30 110 DNS network parameters Field Description DNS Proxy Enabled Select this checkbox to enable DNS proxy Domain Name Domain name IPv4 Address Domain IP address Origin Domain Origin domain name New Domain New domain name Enter the domain name and IP address and click Add. If required, associate an origin domain with a new domain, click Add. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 24 Configure an XS-240W-A or XS-250WX-A indoor ONT TR-069 configuration Select Network > TR-069 from the top-level menu in the 10G PON Gateway window, as shown in Figure 45. Figure 45 TR-069 network window Table 31 describes the fields in the TR-069 network window. Table 31 Issue: 01 TR-069 network parameters Field Description Periodic Inform Enable Select this checkbox to enable periodic inform updates Periodic Inform Interval(s) Time between periodic inform updates, in seconds URL URL of the auto-configuration server Username Username used to log in to the auto-configuration server Password Password used to log in to the auto-configuration server Connect Request Username Username used to log in to the ONT Connect Request Password Password used to log in to the ONT Configure TR-069 by entering the required information. 3FE-48631-AAAA-TCZZA 111 Configure an XS-240W-A or XS-250WX-A indoor ONT Click Save. STOP. This procedure is complete. Procedure 25 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide QoS configuration Note that forwarding policy is not supported in Release 5.6. Select Network > QoS Config from the top-level menu in the 10G PON Gateway window. Figure 46 shows the QoS Config window for QoS L2 (Layer 2 packet sizes). The window for QoS L3 shows additional fields, as described in Table 32. Figure 46 QoS Config window (L2) Table 32 describes the fields in the QoS Config window. 112 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 32 Configure an XS-240W-A or XS-250WX-A indoor ONT QoS Config parameters Field Description Type Choose a QoS type from the drop-down menu: L2 or L3 Source MAC Enter the source MAC. Select the Exclude checkbox to exclude the source MAC Interface Choose an interface from the drop-down menu 802.1p Mark Enter the value for the 802.1p (range: 0-7) DSCP Mark Enter the value for the DSCP mark (range: 0-63) Additional fields for L3 Protocol Select a protocol from the drop-down menu, or select the Exclude checkbox Application Select an application from the drop-down menu Source IP and Source IP Mask Enter the values for the source IP and IP mask, or select the Exclude checkbox Destination IP and Destination IP Mask Enter the values for the destination IP and IP mask, or select the Exclude checkbox Source Port and Source Port Max Enter the values for the source port and port max (highest port number) or select the Exclude checkbox Destination Port and Destination Port Max Enter the values for the destination port and port max (highest port number), or select the Exclude checkbox Choose a QoS type from the drop-down menu: L2 or L3. Configure a QoS policy. Click Add to add a QoS policy. STOP. This procedure is complete. 8.2.4 Security configuration XS-240W-A and XS-250WX-A ONT also supports security configuration, including: • • • • Issue: 01 firewall MAC filter IP filter URL filter 3FE-48631-AAAA-TCZZA 113 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide • DMZ and ALG • access control Note that parent control is not supported in Release 5.6. Procedure 26 Firewall configuration Select Security > Firewall from the top-level menu in the 10G PON Gateway window, as shown in Figure 47. Figure 47 Firewall window Firewall security applies only to services provided by the ONT. Internet access from the LAN side is not affected by this firewall. Three security levels are available: Low, Medium, and High. At the Low level, pre-routing is supported: port forwarding, DMZ, host application, and host drop. Also supported are application services: DDNS, DHCP, DNS, H248, IGMP, NTP client, SSH, Telnet, TFTP, TR-069, and VoIP. At the Medium level, pre-routing is supported: port forwarding, DMZ, host application, and host drop. Also supported are application services: DDNS, DHCP, DNS, H248, IGMP, NTP client, TFTP, TR-069, and VoIP. The following types of ICMP messages are permitted: echo request and reply, destination unreachable, and TTL exceeded. Other types of ICMP messages are blocked. DNS proxy is supported from LAN to WAN but not from WAN to LAN. At the High level, pre-routing and application services are not supported. UDP Port 8000 can be used to access the services, for example FTP can use 8021 and Telnet can use 8023. Regular UDP cannot be used. RG access is permitted via the LAN side but not via the WAN side. 114 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Configure an XS-240W-A or XS-250WX-A indoor ONT Table 33 describes the fields in the firewall window. Table 33 Firewall parameters Field Description Security level Choose the security level from the drop-down menu: low, medium, or high Attack Protect (Protection against DoS or DDoS attacks) Choose enable or disable attack protect from the drop-down menu The default is disable Configure the firewall. Click Save. STOP. This procedure is complete. Procedure 27 MAC filter configuration Select Security > Mac Filter from the top-level menu in the 10G PON Gateway window, as shown in Figure 48. Figure 48 MAC filter window Table 34 describes the fields in the MAC filter window. Issue: 01 3FE-48631-AAAA-TCZZA 115 Configure an XS-240W-A or XS-250WX-A indoor ONT Table 34 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide MAC filter parameters Field Description Enable MAC filter Select this checkbox to enable the MAC filter Mac Address Select a MAC address from the drop-down menu or enter the address in the text field Mac Filter Mode Choose the MAC filter mode from this drop-down menu: Blocked or Allowed Click Refresh to update the information. Configure a MAC filter. Click Add. STOP. This procedure is complete. Procedure 28 IP filter configuration Select Security > IP filter from the top-level menu in the 10G PON Gateway window, as shown in Figure 49. Figure 49 IP filter window Table 35 describes the fields in the IP filter window. 116 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 35 IP filter parameters Field Description Enable IP Filter Select this checkbox to enable an IP filter Mode Choose an IP filter mode from the drop-down menu: Internal Client Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT • • Drop for upstream Drop for downstream Choose an internal client from the drop-down menu: • • Customer setting - uses the IP address input below IP - uses the connecting devices' IP to the ONT Local IP Address Local IP address Source Subnet Mask Source subnet mask Remote IP Address Remote IP address Destination Subnet Mask Destination subnet mask Protocol Choose an application protocol or all from the drop-down menu Configure the IP filter. Click Add. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 117 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 29 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide URL filter configuration Select Security > URL Filter from the top-level menu in the 10G PON Gateway window, as shown in Figure 50. Figure 50 URL Filter window Note — You cannot use URL filtering for HTTPS. The URL is encrypted when using HTTPS. Table 36 describes the fields in the URL Filter window. Table 36 118 URL Filter parameters Field Description Enable URL filter Select the checkbox to enable the URL filter URL filter type Select the checkbox for Exclude URL or Include URL URL Address Type the URL address Port Number Type the port number; the default is 80 Configure the URL Filter. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Click Add Filter. STOP. This procedure is complete. Procedure 30 Configure an XS-240W-A or XS-250WX-A indoor ONT DMZ and ALG configuration Select Security > DMZ and ALG from the top-level menu in the 10G PON Gateway window, as shown in Figure 51. Figure 51 DMZ and ALG window Table 37 describes the fields in the DMZ and ALG window. Table 37 DMZ and ALG parameters Field Description ALG Config Select the checkboxes to enable the protocols to be supported by the ALG: FTP, TFTP, SIP, H323, RTSP, L2TP, IPSEC, PPTP DMZ Config Issue: 01 WAN Connection List Choose a WAN connection from the drop-down menu Enable DMZ Select this checkbox to enable DMZ on the chosen WAN connection DMZ IP Address Choose Customer Setting and enter the DMZ IP address or choose the IP address of a connected device from the drop-down menu 3FE-48631-AAAA-TCZZA 119 Configure an XS-240W-A or XS-250WX-A indoor ONT 120 Configure ALG. Click Save ALG. Configure DMZ. Click Save DMZ. STOP. This procedure is complete. 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 31 Configure an XS-240W-A or XS-250WX-A indoor ONT Access control configuration This procedure describes how to configure the access control level (ACL). Note 1 — ACL takes precedence over the firewall policy. Note 2 — The trusted network object will be shared for all WAN connections; it is not applied individually to a WAN connection. Select Security > Access Control from the top-level menu in the 10G PON Gateway window, as shown in Figure 52. Figure 52 Access Control window Table 38 describes the fields in the Access Control window. Table 38 Access control parameters Field Description WAN Choose a connection from the drop-down menu Trusted Network Enable Select this checkbox to enable trusted network (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 121 Configure an XS-240W-A or XS-250WX-A indoor ONT 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description ICMP, Telnet, SSH, HTTP, TR-069, HTTPS Select an access control level for each protocol: WAN side: Allow, Deny, or Trusted Network Only LAN side: Allow or Deny Source IP Start Enter a start IP address for the new subnet trusted network Source IP End Enter an end IP address for the new subnet trusted network (2 of 2) Select a WAN connection from the drop-down menu. Select the checkbox to enable Trusted Network. Select an access control level for each of the four protocols: ICMP, SSH, HTTP, and TR-069 for both the WAN and the LAN side. Click Save. Optionally, add one or more subnet trusted networks. The maximum number of entries is 32. You can also use the Source IP fields to delete a previously created entry for a subnet trusted network. 8.2.5 STOP. This procedure is complete. Application configuration XS-240W-A and XS-250WX-A ONT also supports application configuration, including: • • • • • • port forwarding DDNS NTP USB UPnP and DLNA voice setting Note that port triggering is not supported in release 5.6. 122 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 32 Configure an XS-240W-A or XS-250WX-A indoor ONT Port forwarding configuration Select Application > Port forwarding from the top-level menu in the 10G PON Gateway window, as shown in Figure 53. Figure 53 Port forwarding window Table 39 describes the fields in the port forwarding window. Table 39 Port forwarding parameters Field Description Application Name Choose an application name from the drop-down menu WAN Port WAN port range LAN Port LAN port range Internal Client Choose a connected device from the drop-down menu and enter the associated IP address Protocol Choose the port forwarding protocol from the drop-down menu: • • • TCP UDP TCP/UDP Enable Mapping Select this checkbox to enable mapping WAN Connection List Choose a WAN connection from the drop-down menu Note: only active devices are shown on this menu Issue: 01 3FE-48631-AAAA-TCZZA 123 Configure an XS-240W-A or XS-250WX-A indoor ONT Configure port forwarding. Click Add. STOP. This procedure is complete. Procedure 33 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide DDNS configuration Select Application > DDNS from the top-level menu in the 10G PON Gateway window, as shown in Figure 54. Figure 54 DDNS window Table 40 describes the fields in the DDNS window. Table 40 DDNS parameters Field Description WAN Connection List Choose a WAN connection from the drop-down menu Enable DDNS Select this checkbox to enable DDNS on the chosen WAN connection ISP Choose an ISP from the drop-down menu. Domain Name Domain name Username Username (1 of 2) 124 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Field Description Password Password Configure an XS-240W-A or XS-250WX-A indoor ONT (2 of 2) Configure DDNS. Click Save. STOP. This procedure is complete. Procedure 34 NTP configuration Select Application > NTP from the top-level menu in the 10G PON Gateway window, as shown in Figure 55. Figure 55 Issue: 01 NTP window Select the checkbox to enable NTP service. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 125 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 35 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide USB configuration You can connect USB storage devices and USB printers to the USB ports of the device. The USB menu enables you to configure FTP and SFTP servers for your USB storage devices. You can also use the USB menu to enable and disable USB printer sharing across clients on the LAN. The USB connected devices are shown in overview table on the bottom of the USB window. The device incorporates a CUPS server to enable USB printer sharing across the LAN by using the RAW print-through protocol. When a USB printer is connected to the device, it can be configured on LAN clients by referring to http://:631/printers/ as a shared printer, where refers to the DNS name or the IP address of the device and the is displayed in the connected USB device table of the USB page. The USB printer driver must be installed on the LAN client to execute print jobs. When an error prevents the print job from being completed, a generic error message is returned to the LAN client. Up to four print jobs at a time are supported. Select Application > USB from the top-level menu, as shown in Figure 56. Figure 56 USB window Table 41 describes the fields in the USB window. 126 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Table 41 Configure an XS-240W-A or XS-250WX-A indoor ONT USB parameters Field Description Enable FTP server Select this checkbox to enable using an FTP server Username Username for FTP server Password Password for FTP server Re-enter Password Password for FTP server Enable SFTP server Select this checkbox to enable using an SFTP server Enable SFTP for Remote Access Select this checkbox to enable SFTP for remote access Username Username for SFTP server Password Password for SFTP server Re-enter Password Password for SFTP server Enable Printer Sharing Select this checkbox to enable printer sharing Printer sharing is disabled by default Connected USB devices Issue: 01 For each printer that is connected to the ONT, the following fields are displayed: • Host Number for example: Printer1, Printer2 • Device Name: name or identification for the USB device • Format: for a USB printer, the printing protocol is RAW; for a USB storage device, this field displays the storage format • Total space (applies only to a USB storage device) • Free space (applies only to a USB storage device) Configure USB. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 127 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 36 UPnP and DLNA configuration Select Application > UPnP and DLNA from the top-level menu in the 10G PON Gateway window, as shown in Figure 57. Figure 57 128 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide UPnP and DLNA window Select the Enable UPnP checkbox to enable UPnP. Click Save/Apply. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 37 Configure an XS-240W-A or XS-250WX-A indoor ONT Voice setting Voice setting can only be uses in TR-069 mode. Select Application > Voice Setting from the top-level menu in the 10G PON Gateway window, as shown in Figure 58. Figure 58 Voice setting window Table 42 describes the fields in the Voice Setting window. Issue: 01 3FE-48631-AAAA-TCZZA 129 Configure an XS-240W-A or XS-250WX-A indoor ONT Table 42 Voice setting parameters Field Description Outbound Proxy Enter the SIP outbound proxy Outbound Proxy Port Enter the outbound proxy port Proxy Server Enter the proxy server Proxy Port Enter the proxy port Register Server Enter the register server Register Port Enter the register port User Agent Domain Enter the user agent domain DTMF Mode Choose InBand, rfc2822, Info, or Auto from the drop-down menu FaxT38 Choose False or True from the drop-down menu Line Choose a line from the drop-down menu Enable Choose Enabled or Disabled from the drop-down menu Directory Number Enter a directory number AuthUserName Enter an authorized user name AuthPassword Enter a password for the user Configure voice setting. Click Save. STOP. This procedure is complete. 8.2.6 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Maintenance XS-240W-A and XS-250WX-A ONT also supports maintenance tasks, including: • • • • • • • • 130 change password configure LOID configure SLID manage device backup and restore upgrade firmware reboot device restore factory defaults 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Configure an XS-240W-A or XS-250WX-A indoor ONT • diagnose WAN connections • view log Procedure 38 Password configuration A password must adhere to the password rules, which are as follows: • • • • • the password may consist of uppercase letters, lowercase letters, digital numbers, and the following special characters ! # + , - / @ _ : = ] the password length must be from 8 to 24 characters the first character must be a digital number or a letter the password must contain at least two types of characters: numbers, letters, or special characters the same character must not appear more than 8 times in a row When the password meets the password rules, the application displays the message “Your password has been changed successfully”. When the password does not meet the password rules, the application displays a message to indicate which password rule has not been followed, for example: • • • • Issue: 01 the password is too short the password is too long the first character cannot be a special character there are not enough character classes Select Maintenance > Password from the top-level menu in the GPON Home Gateway window, as shown in Figure 59. 3FE-48631-AAAA-TCZZA 131 Configure an XS-240W-A or XS-250WX-A indoor ONT Figure 59 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Password window Table 43 describes the fields in the password window. Table 43 132 Password parameters Field Description New Password New password (must adhere to the password rules described above) Re-enter password Must match the new password entered above exactly Prompt message Password prompt message Configure the new password. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 39 Configure an XS-240W-A or XS-250WX-A indoor ONT LOID configuration Select Maintain > LOID Config from the top-level menu in the 10G PON Gateway window, as shown in Figure 60. Figure 60 LOID Config window Table 44 describes the fields in the LOID configuration window. Table 44 LOID configuration parameters Field Description LOID Type the LOID; the maximum number of characters is 24 If the password is null, this field may be left blank Password Issue: 01 Type the password; the maximum number of characters is 12 Configure the LOID. Click Save/Apply. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 133 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 40 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide SLID configuration Select Maintain > SLID Configuration from the top-level menu in the 10G PON Gateway window, as shown in Figure 61. Figure 61 SLID configuration window Table 45 describes the fields in the SLID configuration window. Table 45 134 SLID configuration parameters Field Description Current SLID Displays current SLID Input new SLID Enter new SLID SLID Mode Choose a SLID mode from the drop-down menu. Configure the new SLID. Click Save. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 41 Configure an XS-240W-A or XS-250WX-A indoor ONT Device management Select Maintain > Device Management from the top-level menu in the 10G PON Gateway window, as shown in Figure 62. Figure 62 Device management window Table 46 describes the fields in the Device management window. Table 46 Issue: 01 Device management parameters Field Description Host name Choose a host from the drop-down menu Alias Enter an alias for the chosen host Configure an alias for a specific host. Click Add. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 135 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 42 Backup and restore Select Maintain > Backup and Restore from the top-level menu in the 10G PON Gateway window, as shown in Figure 63. Figure 63 136 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Backup and Restore window Click Select File and choose the backup file. Click Import Config File to restore the ONT to the saved backup or click Export Config File to export the current ONT configuration to the backup file. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 43 Upgrade firmware Select Maintain > Firmware Upgrade from the top-level menu in the 10G PON Gateway window, as shown in Figure 64. Figure 64 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT Firmware upgrade window Click Select File and choose the firmware file. Click Upgrade to upgrade the firmware. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 137 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 44 Reboot ONT Select Maintain > Reboot Device from the top-level menu in the 10G PON Gateway window, as shown in Figure 65. Figure 65 138 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Reboot window Click Reboot to reboot the ONT. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 45 Restore factory defaults Select Maintain > Factory Default from the top-level menu in the 10G PON Gateway window, as shown in Figure 66. Figure 66 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT Factory default window Click Factory Default to reset the ONT to its factory default settings. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA 139 Configure an XS-240W-A or XS-250WX-A indoor ONT Procedure 46 Diagnose WAN connections Select Maintain > Diagnose from the top-level menu in the 10G PON Gateway window, as shown in Figure 67. Figure 67 140 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Diagnose window Choose a WAN connection to diagnose from the drop-down menu. Enter the IP address or domain name. Select the test type: ping, traceroute, or both. Enter the number of ping attempts to perform (1 - 1000); the default is 4. Enter a ping packet length (64-1024); the default is 64. Enter the maximum number of trace hops (1-255); the default is 30. Click Start Test. Results will be displayed at the bottom of the window. 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Click Cancel to cancel the test. 10 STOP. This procedure is complete. Procedure 47 View log files Select Maintain > Log from the top-level menu in the 10G PON Gateway window, as shown in Figure 68. Figure 68 Issue: 01 Configure an XS-240W-A or XS-250WX-A indoor ONT Log window 3FE-48631-AAAA-TCZZA 141 Configure an XS-240W-A or XS-250WX-A indoor ONT Choose a write level from the drop-down menu to determine which types of events are recorded in the log file: • • • • • • • • Emergency Alert Critical Error Warning Notice Informational Debug Choose a reading level from the drop-down menu to determine which types of events to display from the log file: • • • • • • • • 8.2.7 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Emergency Alert Critical Error Warning Notice Informational Debug The log file is displayed at the bottom of the window. STOP. This procedure is complete. RG troubleshooting counters The Troubleshooting Counters feature enables service providers and end users to monitor the performance of their broadband connection. Tests are run to retrieve upstream and downstream throughput, latency, and DNS response time. The Troubleshooting Counters window also displays upstream and downstream packet loss and Internet status. Note that port mirroring is not supported in Release 5.6. 142 3FE-48631-AAAA-TCZZA Issue: 01 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Procedure 48 Configure an XS-240W-A or XS-250WX-A indoor ONT Retrieve Residential Gateway (RG) troubleshooting counters Select RG Troubleshooting Counters from the left menu in the 10G PON Gateway window. The RG Troubleshooting Counters window appears; see Figure 69. Figure 69 RG Troubleshooting Counters window Table 47 describes the fields in the RG Troubleshooting Counters window. Table 47 RG Troubleshooting Counters parameters Field Description WAN Connection List Select a WAN connection from the list (1 of 2) Issue: 01 3FE-48631-AAAA-TCZZA 143 Configure an XS-240W-A or XS-250WX-A indoor ONT Field US Throughput 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Description This test is used to determine the upstream throughput/speed Click US Speed Test to specify the time for the upstream test The default is weekly, performed at idle to a public server DS Throughput This test is used to determine the downstream throughput/speed Click DS Speed Test to specify the time for the downstream test The default is weekly, performed at idle to a public server US Packet Loss The number of upstream packages lost DS Packet Loss The number of downstream packages lost Internet Status Whether the broadband connections is active (UP) or not (DOWN) Latency This test is used to determine the lowest round-trip time in milliseconds by pinging the target server multiple times Click Latency Test to specify the time for the test The default is weekly, performed at idle to a public server DNS Response Time This test is used to determine the lowest round-trip time in milliseconds by sending a request to the target DNS server Click DNS Response Test to specify the time for the test The default is weekly, performed at idle to a public server (2 of 2) 144 Configure the test times if desired. Click Refresh to update the data. STOP. This procedure is complete. 3FE-48631-AAAA-TCZZA Issue: 01 Customer document and product support Customer documentation Customer Documentation Welcome Page Technical Support Customer Documentation Technical Support Documentation feedback Customer Documentation Feedback Copyright 2018 Nokia. 3FE-48631-AAAA-TCZZA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Nokia Create Date : 2018:04:24 13:33:44Z Modify Date : 2018:05:02 12:03:16-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Format : application/pdf Creator : Nokia Title : 7368 ISAM ONT XS-240W-A XS-250WX-A Product Guide Creator Tool : FrameMaker 11.0.2 Metadata Date : 2018:05:02 12:03:16-04:00 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:a14e4664-43f2-4e7b-a527-e9f6a0b5903b Instance ID : uuid:3b78c868-e6e8-4f5a-99ba-718ef23ef0a6 Page Mode : UseOutlines Page Count : 146EXIF Metadata provided by EXIF.tools