Nokia Solutions and Networks FXFA-01 FXFA User Manual 1
Nokia Solutions and Networks FXFA Users Manual 1
Contents
- 1. Users Manual 1
- 2. Users Manual 2
- 3. Users Manual 3
- 4. Users Manual 4
Users Manual 1
Flexi Multiradio BTS GSM/EDGE Stack, Wall, and Pole Quick Guide This guide can be used as quick reference for Flexi Multiradio BTS GSM/EDGE installation. Flexi Multiradio BTS GSM/EDGE is a modular base station for GSM/EDGE capacity and coverage. It can be installed stacked on the floor, or mounted on the wall or on the pole. This quick guide is for basic stack, wall and pole configurations with 48V DC input power. The basic installation consists of one System Module (ESMB/C) and one RF Module (Fxxx) allowing 1+1+1 up to 6+6+6 configurations depending on the TRX output power. For all other installation options, see the user manuals. Check the delivery Contents of 1 delivery Check the site Clearances Installation 3 Installing the plinth Plinth on the floor, wall, or pole Installation Installation Installation Installation 4 Grounding 5 Installing the 6 Installing 7 Grounding Grounding principle Casing installation principle Module installation principle Grounding principle the plinth casings the modules modules Installation example Cabling 8 Cabling Cable routing and cable ties External power Internal power cables Antenna cabling Optical cables Transmission and Alarm cables Commission BTS 9 Power up and commissioning the BTS Front panel 10 Installing module front covers The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2010. All rights reserved. DN70970932, Issue 01 en Warning Danger of eye damage from invisible laser radiation produced by the System Module optical fibre connector! Always switch off the laser before detaching the optical fibre from the connector. Caution Incorrect cables and seals may not provide secured environmental protection. Use only tested IP65 class cables with seals provided by Nokia Siemens Networks. Store all unused seals for later use. Electrostatic discharge (ESD) may damage the modules. Wear an ESD wrist strap or use a corresponding method when handling the modules. The rear stopper is fragile. Do not attempt to lift the plinth using the rear stopper. If water leaks into the outdoor mechanics, the transmission equipment may fail. To help prevent water leakage, feed the cables through the bottom cable entries in wall and pole mounting, and through the bottom cable entry holes in stack installation. Risk of damage to equipment. If modules are exposed to weather conditions, connector seals or boots must be installed at all times, whether the site is active or not. 1 Contents of delivery De live ry Syste m m o du le C on ten ts o f de live ry Ve rs io n Pr od u ct c o de F lexi Multira dio B TS GSM/ED GE Sys te m Mo d ule Qua n tity ES MB ES MC 4 7 21 0 9 4 7 20 5 9 Ba g R eclo s ab le (15 0 x 2 25 / 2 00 x 2 6 0 ) 0 .1 m m M1 0 H e x N u t B1 0 Wa sh e r AWG Sin g le ca b le term in a l lug rub b er b o ots M1 0 C a b lete rm (2 5/3 5 m m 2 ) R ing Pu ll-ou t to ol T ra n sm iss io n su b -m od u le F lexi tran s m is sio n inte rfac e E 1 a sym m etrica l su b m o du le (FIE A) F lexi tran s m is sio n inte rfac e F lexb us s ub -m o du le (F IF A) F lexi tran s m is sio n inte rfac e E 1/T 1 s ym m e trica l s ub m o d ule (F IPA) 47 0 24 7 A 47 1 00 7 A 47 0 24 8 A 47 1 60 7 A PW 1 00 Ba s e-T Eth ern et (R J4 8 ) + 4 xE 1 a s ym m etrica l 75 o hm (SMB) + o pti on a l op tica l GE (SF P) 47 1 71 9 A F XD A F le xi Mu ltira d io R F M 9 0 0 F XE A Fle xi Mu ltirad io R FM 18 0 0 F XC A F le xi Mu ltira d io R F M 8 5 0 F XD J Fle xi Mu ltirad io R FM 90 0 F XF A F lexi Multira dio R F M 1 90 0 47 2 08 3 A 47 2 08 4 A 47 2 14 2 A 47 2 14 3 A 47 2 16 6 A F lexi tran s m is sio n su b -m o du le (FIQ A) PW 1 00 Ba s e-T Eth ern et (R J4 8 ) + 4 xE 1/T 1 sym m e trical 1 2 0/ 10 0 oh m (R J4 8) + op tio na l o ptica l GE (S FP ) F lexi tran s m is sio n su b -m o du le (FIYA) Scre w s (p re -in sta lle d) R F Mod u le F lexi Multira dio B TS GSM/ED GE R ad io F re q ue n cy Mo du le R F Mod u le C a b le Se t Po w e r ca b le 2 m Op tical ca b le 2 m Op tical tra nce ivers Plin th de livery Mo du le cas in g 9 9 52 8 1 9 9 48 0 7 47 0 74 5 7 F lexi Mou n ting K it for F loo r, Wa ll, an d Po le F ixin g p la te fo r th e ca s ing M5 x 8 scre w s M5 x 1 2 s crew s F MF A F lexi BT S Mo du le ca sin g (3 U ) 3 U cab le en trie s 3 U fro n t cover 3 U re a r co ve r M5 x 1 0 s crew s M5 x 8 scre w s EMH A 12 47 0 31 6 A 61 5 02 4 0 61 5 02 7 9 C a ge n uts Ma inte n an ce s tra p s Grou n din g cab le Po le m o un tin g kit (op tio na l) F lexi Po le Mo u n ting Kit Alum iniu m ca s tin gs Ass e m b ling b o lts Mo du le fixin g s cre w s Bo lt res train e r Check list Deliveries are complete. Equipment is not damaged. F PK A 6 (2 loo s e, 4 p reins ta lled ) 47 1 64 9 A 2 Clearances Minimum clearances min 80 mm (3.2 in.) min 30 mm with no back access (1.2 in.) min 80 mm (2.4 in.) 600 mm (23.6 in) min 100 mm (3.9 in.) min 75 mm (3.0 in.) 400 mm (15.7 in) recommended space for hand tying 150 mm (5.9 in.) Check list Note: In a stack, the minimum side clearance is 75 mm (3 in.). The recommended clearance for hand tying is 150mm (5.9 in.) Site meets the minimum clearances. Plinth on the floor Facility wall 3 Installing the plinth 1. Check the clearances around the plinth. 2. Turn the rear stopper. 360 mm 75 mm (3.0 in.) (14.1 in.) 13.5 mm (0.5 in.) (4 pcs) 75 mm (3.0 in.) Fan maintenance space 500 mm (19.7 in.) back stop Plinth min 600 mm (23.6 in.) 3. Place the plinth on the floor, grounding points facing forward. 4. Bolt on the floor with 4 bolts, 12 mm (0.47 in.) in diameter. Tighten to 49.0 Nm (36.1 ft-lb) 300 mm (11.8 in.) Plinth on the wall 482,5 mm 185 mm 1. Mark screw locations according to the holes in the plinth and drill holes. 2. Fix the mounting screws on the wall and mount the plinth. 3. Tighten the upper mounting screws. 4. Tighten the lower mounting screws to a torque value of 49 Nm. Note that the space required between plinths is 100 mm (3.4 inches).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Modify Date : 2011:07:11 09:13:10-04:00 Create Date : 2011:07:08 10:49:58-05:00 Metadata Date : 2011:07:11 09:13:10-04:00 Format : application/pdf Title : Flexi Multiradio BTS GSM EDGE Stack, Wall, Pole Quick Guide.des Creator : ©2010 by Nokia Siemens Networks Document ID : uuid:79e716d2-650d-45b2-8852-935a96cc7b45 Instance ID : uuid:155f773f-d8dd-4fdd-a2f9-68d1f0322e26 Producer : Corel PDF Engine Version 14.1.0.195 Page Count : 4 Author : ©2010 by Nokia Siemens NetworksEXIF Metadata provided by EXIF.tools