Nokia Solutions and Networks FZCWI2A1 Wireless Access Point User Manual 10 23
Nokia Solutions and Networks, OY Wireless Access Point 10 23
Contents
- 1. User Manual Regulatory Information_10.23.pdf
- 2. User Manual_10.23.pdf
- 3. User Manual - Regulatory Information_11.15.pdf
User Manual_10.23.pdf
Nokia Wi-Fi Access Point WI2A-AC200i 5G Thank you for buying a Nokia Wi-Fi Access Point WI2A-AC200i. 2.4G This Quick Installation Guide Nokia Wi-Fi Access Point WI2A-AC200i provides basic information and step-by-step installation instructions. Following these steps will enable you to properly install the WI2A-AC200i at your site. ETH CTRL PWR Pre-requisites • Please read all the notes and safety statements in this guide before beginning the installation process. • The WI2A-AC200i is designed for an indoor environment (e.g. temperature range of 0°C to 40°C, non-condensing). • Allow 10 cm of space around the access point to ensure proper cooling. • Install the WI2A-AC200i away from heat sources, water/wet surfaces, and strong magnetic field sources or electrical appliances (ex: microwave ovens). • Using an incorrect power adapter may permanently damage the product. 5 GHz 2.4 GHz Legal Notices • Nokia Solutions and Networks 2015. © The information contained herein is subject to change without notice. The only warranties for Nokia products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Nokia Solutions and Networks shall not be liable for technical or editorial errors or omissions contained herein. ETH Label Statements CTRL Label material and adhesive have been designed to last the lifetime of the product when installed in accordance with Nokia installation guidelines. Package Contents • • • • • Access point Bracket Logo sticker Quick Installation Guide Regulatory Information Tools Required • • • • • Marker Measuring tape Screws Screw driver Hammer Color – Indication LED PWR Accessories Needed • Network cables • POE power or DC power adapter Off - No SSID Configured on 5 GHz Green - 5 GHz SSID Configured and Broadcasting Red – AP is locked by Controller Off - No SSID Configured on 2.4 GHz Green - 2.4 GHz SSID Configured and Broadcasting Red – AP is locked by Controller Off - LAN Connection Not Detected Red - LAN Connection Detected Red blinking - AP IP address Discovery process Green - AP IP address obtained (DHCP or Static but not factory default) Green blinking - LAN Activity after IP address has been obtained Off - LAN Connection Not Detected or AP IP Address not available Red - AP IP address available but Controller IP is being discovered or Invalid Controller IP Red blinking - Controller IP Available and Connection in Progress Green -Connected to Controller and in steady state Green blinking - Connected to Controller and Configuration in Progress Amber blinking - Connected to Controller and Software Download in Progress Off - No Power to AP Red - Board Power On Red blinking - Loading Software Green - Software Loaded Red blinking for more than 5 minutes - Failure to load Software properly (if LED control is working) Specification Summary The following table describes the physical, electrical and environmental specifications. 1. Before unpacking the carton, ensure that the packaging is intact, not damaged or soaked. 2. Unpack the carton and check if all the items listed in the package contents are included. NOTE 3. Tools are not supplied with the WI2A-AC200i box. Description LAN PORT Port for Ethernet cable to connect the WI2A-AC200i to LAN and POE (if available). Reset button Used to reboot or restore WI2A-AC200i. Press and release the button to reboot WI2A-AC200i. Press and hold the button for 10 seconds to restore factory settings. Power port Security Lock Slot Dimensions 150mm x 150mm x 30mm (without bracket) Item Description 400g Nokia WI2A-AC200i electrical specification Name Item Weight Product Overview Number Nokia WI2A-AC200i physical specification Port to connect a DC power supply unit if POE is unavailable. Slot for security lock and cable for theft protection. Power input Power consumption Description +12V/1A ≤12W Nokia WI2A-AC200i environmental specification Item Description Working temperature 0°C ~ +40°C Operating humidity 5% to 95% non-condensing Dustproof and Waterproof IP20 2 Hardware Operation The Nokia® WI2A-AC200i can be ceiling or wall mounted. Ceiling mounting is recommended. Please read the safety instructions before working with the product. Scenario 2: Wall mounting 1. Align the securing hook of WI2A-AC200i with the bracket. 2. To firmly fasten the WI2A-AC200i to the bracket, rotate the bracket in the clockwise direction (as shown in the figure on the right) until it completely locks into the WI2A-AC200i. 3. Drive two screws in the wall with a distance of 79mm between them. 4. Align the bracket hole with the screws, and then pull the bracket down over the screws until it is tightly fastened. Ensure that Nokia WI2A-AC200i is securely installed. Poor installation may cause the device to fall and be damaged. NOTE 79mm Securing Hook Connecting cables The following figure illustrates the interface and cable connections of the WI2A-AC200i: Item Description Name NOTE • Category-5 Enhanced Ethernet cable is recommended. Ethernet cable DC Power adapter Downward Recommended wall mounting for the WI2A-AC200i is with the cables run upward. • Ensure that the WI2A-AC200i is connected to the LAN using a correct Ethernet cable. If the cables are run downward, the Nokia Logo sticker can be placed on the WI2A-AC200i to display an upright Nokia logo. Cabling options are shown in the figure to the right. • The WI2A-AC200i might fail to power up or work if non-standard Ethernet cable is used. Placing of Nokia Logo sticker while wall mounting • A DC power adapter is required only if a PoE power supply is not available. • To connect the WI2A-AC200i to a DC power source and prevent damage, use the power adapter specified for the WI2A-AC200i. The WI2A-AC200i requires either PoE or DC power supply to operate. To use the PoE power supply: Connect the WI2A-AC200i to the PoE power supply (such as PoE injector or PoE switch) using an Ethernet cable. Logo sticker Upward Installing the security lock There is a security lock slot with an anti-theft design provided on the WI2A-AC200i. 1. Fasten the security lock cable to an immovable object. 2. Insert the security lock cable into the security lock slot of the WI2A-AC200i and then lock it. To use the DC power supply: Connect the WI2A-AC200i to the DC power supply. Use only PoE and DC power supplies that meet these specifications: PoE DC Power Adapter NOTE PD: 12.95W, support Category-5 Enhanced 100m cable Voltage range: 37V~ 57V 12 V DC nominal, +/- 5% Scenario 1: Ceiling mounting 1. Choose a pair of bracket clips to firmly mount the bracket with the T-rails. The bracket provides two pairs of clips. Select the correct pair based on the T-rail width. The following figure NOTE illustrates the bracket clips. Bracket Clips1 2. Align the securing hook of the WI2A-AC200i with the secured bracket. 3. To firmly fasten the WI2A-AC200i with the bracket, rotate the WI2A-AC200i in the anti-clockwise direction. Securing Hook Bracket Clips2 T-rail The box does not include a security lock cable. It needs to be purchased separately. Security lock slot Security lock cable
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Adobe PDF library 9.90 Create Date : 2015:10:23 11:07:15+09:00 Modify Date : 2015:10:23 16:12:21+08:00 Creator Tool : Adobe Illustrator CS5 Metadata Date : 2015:10:23 16:12:21+08:00 Thumbnail Width : 192 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 15777 bytes, use -b option to extract) Format : application/pdf Title : Nokia®_AC200i-QIG-front_V1.5 N Pages : 1 Has Visible Transparency : False Has Visible Overprint : True Max Page Size W : 419.999514 Max Page Size H : 289.999870 Max Page Size Unit : Millimeters Font Name : Arial-BoldMT, ArialMT, Arial-BoldItalicMT Font Family : Arial, Arial, Arial Font Face : Bold, Regular, Bold Italic Font Type : Open Type, Open Type, Open Type Font Version : Version 5.20, Version 5.20, Version 5.20 Font Composite : False, False, False Font File Name : arialbd.ttf, arial.ttf, arialbi.ttf Plate Names : Cyan, Magenta, Yellow, Black Swatch Groups Group Name : 默认色板组 Swatch Groups Group Type : 0 Swatch Groups Colorants Swatch Name: Raid Controller Orange Swatch Groups Colorants Type : SPOT Swatch Groups Colorants Tint : 100.000000 Swatch Groups Colorants Mode : CMYK Swatch Groups Colorants Cyan : 0.000000 Swatch Groups Colorants Magenta : 26.999998 Swatch Groups Colorants Yellow : 100.000000 Swatch Groups Colorants Black : 1.000000 Document ID : xmp.did:E3CB8A263379E511B2F8BE576D4E7267 Instance ID : uuid:577553ca-0aa6-4e45-b4c6-2337e3bb52e3 Original Document ID : xmp.did:D3751531D8FAE411B0CE92602E7A2110 Rendition Class : proof:pdf Derived From Instance ID : uuid:3f6aa1fa-22a9-47c0-b9aa-9357a400e25e Derived From Document ID : xmp.did:F3E2BE442376E511B7F8EFE62FC94016 Derived From Original Document ID: xmp.did:D3751531D8FAE411B0CE92602E7A2110 Derived From Rendition Class : proof:pdf History Action : saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:D3751531D8FAE411B0CE92602E7A2110, xmp.iid:e62b4829-4448-5141-b17c-de9a2f09372d, xmp.iid:CBB0E152463FE511979284F63E256D3C, xmp.iid:258AC201F93FE511B15D8C407FDCBED8, xmp.iid:9357078F5951E5118B949419DF866E80, xmp.iid:127BBCADC670E511A04CEC82868D9361, xmp.iid:F3E2BE442376E511B7F8EFE62FC94016, xmp.iid:E3CB8A263379E511B2F8BE576D4E7267 History When : 2015:05:19 14:57:22+08:00, 2015:08:05 12:31:38+05:30, 2015:08:10 17:58:37+08:00, 2015:08:11 15:17:21+08:00, 2015:09:02 18:01:19+08:00, 2015:10:12 17:50:32+08:00, 2015:10:19 13:35:55+08:00, 2015:10:23 11:07:10+08:00 History Software Agent : Adobe Illustrator CS5, Adobe Illustrator CC 2015 (Windows), Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5 History Changed : /, /, /, /, /, /, /, / Page Count : 2 Creator : Adobe Illustrator(R) 15.0 For : Pan Xiaoyan, Bounding Box : -1 -383 1217 1237 Container Version : 11 Creator Version : 15EXIF Metadata provided by EXIF.tools