Nokia Solutions and Networks PCS002 User Manual ITMN BTSE BS11

Nokia Solutions and Networks ITMN BTSE BS11

BS11 Installation test

Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11    DRAFTA30808-X3247-B349-1-7630
CAUTIONNote: This equipment has been tested and found to comply with thelimits for a Class A digital device, pursuant to part 15 of the FCCRules. These limits are designed to provide reasonable protectionagainst harmful interference when the equipment is operated in acommercial environment. This equipment generates, uses, and canradiate radio frequency energy and, if not installed and used inaccordance with the instruction manual, may cause harmfulinterference to radio communications. Operation of this equipment in aresidential area is likely to cause harmful interference in which casethe user will be required to correct the interference at his ownexpense.
 AD – 2 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station EquipmentCopyright (C) Siemens AG 1998Issued by the Public Communication Network GroupHofmannstraße 51D-81359 MünchenTechnical modifications possible.Technical specifications and features are binding only insofar asthey are specifically and expressly agreed upon in a written contract.Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of theparts can also have elevated operating temperatures.Non-observance of these conditions and the safety instructions can result in personal injury or in prop- erty damage.Therefore only trained and qualified personnel may install and maintain the system. The system complies with the standard EN 60950. All equipment connected has to comply with theapplicable safety standards.!
A30808-X3247-B349-1-7630    AD – 3Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11IssuesChange indications (Ind.):N = new; G = modified; 0 = deleted;Document Titel Page(s) Issue/Ind.Register ADMINITMN: BTSE BS11 . . . . . AD . . . . . . . . . . . . . . . . . . . . . . . . . 1... 8 1   ITMN: BTSE BS11 . . . . . BS21 . . . . . . . . . . . . . . . . . . . . . . . 1... 56 1   This document consists of a total of   Pages
AD – 4 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    AD – 5Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11Contents1 BS11 Installation Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-11.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-11.2 Visual Inspection of BTSE mechanics  . . . . . . . . . . . . . . . . . . . . . . . .  BS11-41.3 Visual Inspection of BTSE Electric Installation . . . . . . . . . . . . . . . . . .  BS11-51.4 Abis Interface  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-81.5 Preparation for Offline Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-122 Software Download and Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  173 Execution of Offline Tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-193.1 RF and Function Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-193.2 Start of Abis Simulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-213.3 Database download  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-253.4 Call check with MA-10-Loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-273.5 Bit Error Rate (BERT) Test with MS-Loop  . . . . . . . . . . . . . . . . . . . .  BS21-293.6 Settings at HP 8594A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-313.7 RFI-Confirmation: Unit ATMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-334 Appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-354.1 Frequency/Channel Conversion Table . . . . . . . . . . . . . . . . . . . . . . .  BS21-354.2 Binary-HEX-Decimal Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-454.3 Power/Level Conversion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-454.4 Used Expressions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-465 Abbreviations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABB - 47
AD – 6 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station EquipmentIllustrationsFig. 1.1.1  Installation Test Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BS11-3Fig. 1.3.1 Antenna Cabling (example)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BS11-6Fig. 1.1 Connection panel (for external antenna). . . . . . . . . . . . . . . . . . . . . BS11-9Fig. 1.2 Protection circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BS11-10Fig. 1.4.3 SW3 /The black square stands for toggle) and TB01 ÷ TB04. . . . BS11-11
A30808-X3247-B349-1-7630    AD – 7Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11TablesTab. 1.3.1 Technical Data: BS-11i and BS-11e  . . . . . . . . . . . . . . . . . . . . . . .  BS11-7Tab. 1.2 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-8Tab. 1.1 SW3 dip-switch configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-8Tab. 1.2 TB01 ÷ TB04 configuration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS11-9Tab. 4.1 Frequency/Channel Conversion Table  . . . . . . . . . . . . . . . . . . . .  BS21-35Tab. 4.2 GSM Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-35Tab. 4.3 E-GSM Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-37Tab. 4.1.4 DCS Part 1/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-38Tab. 4.1.5 DCS Part 2/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-39Tab. 4.1.6 DCS Part 3/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-40Tab. 4.1.7 PCS Part 1/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-42Tab. 4.8 PCS Part 2/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-42Tab. 4.9 PCS Part3/3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-44Tab. 4.1 Binary-HEX-Decimal Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-45Tab. 4.1 Power conversion table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  BS21-45
AD – 8 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 1Installation TestBase Transceiver Station Equipment ITMN: BTSE BS111 BS11 Installation Test1.1 Introduction1.1.1 Aims of Installation and CommissioningThe installation and commissioning of a network element followed by unit acceptance is proof of:It is assumed that:The commissioning tests are concentrated on the function of the HW. This limits the commisioning test to simply a function test.This is according to the requirements for modern communication systems regarding self-tests, and a  quick and economic  commissioning procedure. As the  function test is based on self-test routines a high degree of reliability  is achieved.1.1.2 Test StrategyThe commissioning tests are based on the production end-test which is carried out for each BTSE in the customer configuration.The production end-tests are documented in a report which is included in the  BTS delivery, and attached to the site-specific documentation.The commissioning and unit acceptance test can therefore be limited to a simple func-tion test.This checks the above-mentioned aims and can also check whether damage has occured during transport.Any further tests or measurements must only be carried out if suspicion of a fault is proved during the function test.1.1.3 Using the ITMN1.1.3.1 Required knowledgeOnly trained personnel should carry out the installation and installation tests.1.1.3.2 Test EquipmentThe test equipment and tools required for the tests are described in the corresponding chapters.Correct, complete delivery according to network planning and the customer order.Correct mechanical and electrical installation  according to  the installation documents.The functional ability  of the the supplied  HW(correct functioning of the NEs at an interface in relation to other network elements)
BS11 – 2 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment1.1.3.3 Procedure in the Event of FaultsIf faults occur in on-line operation they should be localized and cleared in accordance with the instructions in the User Manual (UMN).1.1.3.4 Procedure in the Event of Serious FaultsSerious faults are those which are not dealt with in the UMN. First the specialist in the installation team should try to clear the fault. If the installation technician is not qualified to eliminate serious faults, a fault report must be filled out, providing the following infor-mation in detail:– description of the test step attempted– description of the system response– description of any system activities taking place at the same time, e.g. work done by other testers during modifications to hardware or softwareThe fault report must be sent to the Technical Assistance Center (TAC).1.1.3.5 Dealing with Defective BTSEIf a BTSE should prove to be defective, it should be sent in appropriate packing to the repair center with the following information:– Name and code number of the BTSE– Description of  the fault
A30808-X3247-B349-1-7630    BS11 – 3Installation TestBase Transceiver Station Equipment ITMN: BTSE BS111.1.3.6  Installation Test SequenceFig. 1.1.1   Installation Test SequenceVisual Check ofBTSE-MechanicsPreparations forOffline TestsExecution ofOffline TestsVISUALCONTROLOFFLINEONLINES T A R TE N DPreparation /Executionof Online TestsVisual Check ofBTSE-Electrics
BS11 – 4 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment1.1.4 Safety Instructions1.1.4.1 System VoltagesThe BTSE requires a power supply voltage from 83 Vac to 265 Vac with frequency from 45 Hz to 65 Hz.1.1.4.2 Changing FusesFuses may only be changed by operater. Only authorized fuses as given in the manual may be used. Fuses are to be changed as described in this manual.1.1.4.3 Grounding of Modules / RacksThe BTSE must be plugged in correctly to ground it before power is switched on. Ground connections between racks must be plugged in correctly.1.1.4.4 CE Declaration of ConformityThe CE declaration of conformity for the product will be fulfilled if the setup and cabling is undertaken in accordance with the specification in the manual and the documentation listed there, such as mounting instructions, cable lists etc.Where necessary, account should be taken of project-specific documentation.Deviations from the specifications or independent changes during setup, such as use of cable types with lower screening values, for example, can lead to the CE requirements being violatad. In such cases the CE declaration of conformity is invalidated and the responsibility passes to the person who has caused the deviations.1.2 Visual Inspection of BTSE mechanicsAll of the visual checks of the BTSE installation mechanical part are listed below.1.2.1 BS - 11 i/900.1– Check that the BTSE has been fastened to the wall or pole in compliance with the safety conditions (refer to Micro BTS-IS para. 2.1). In particular, make sure that the wall or pole is capable of supporting the weight of the BTSE and the stresses due to wind load.– Check that the BTSE code is correct:  it must be 134-1791/01.– Check that the solar shield is the correct color and that it has been correctly mounted.– Where installation of the tilting mechanism is foreseen, check that the inclination is correct.– Check that the antenna panel has been correctly mounted.– Check that all cables necessary for operation are present and that they have been passed through the raceways.– Check that the raceways for cable passage have been correctly positioned and fastened.
A30808-X3247-B349-1-7630    BS11 – 5Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11– Check that the connector panel closing cover with relative wrench is present.1.2.2 BS - 11 e/900.1– Check that the BTSE has been fastened to the wall or pole in compliance with the safety conditions (refer the IMN). In particular, make sure that the wall or pole is capable of supporting the weight of the BTSE and the stresses due to wind load.– Check that the BTSE code is correct:  it must be 134-1791/02.– Check that the solar shield is the correct color and that it has been correctly mounted.– Check that the dummy panel has been correctly mounted.– Check that all cables necessary for operation are present and that they have been passed through the raceways.– Check that the raceways for cable passage have been correctly positioned and fastened.– Check that the antenna (external) has been correctly installed.  Where installation of the tilting mechanism is foreseen, check that the inclination is correct.– Check that the connector panel closing cover with relative wrench is present.1.3 Visual Inspection of BTSE Electric InstallationAll of the visual checks of the BTSE installation electrical part are listed below.1.3.1 BS - 11 i/900.1Open the connector panel cover and check that the following cables are present and correctly connected:– power supply–PCM–RF1.3.2 BS - 11 e/900.1– Carry out the checks indicated in section 5.1.– Check that the antenna cable has been correctly connected (Fig. 5.1.)– Check that the antenna cable has been grounded at the top, in the middle and at the bottom.– Check that the coaxial lightening discharges are present on both antenna cables.– Check the grounding of the cable guiding-slit plate when present.– Check that the antenna is correctly positioned and has the exact tilting value.
BS11 – 6 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station EquipmentFig. 1.3.1  Antenna Cabling (example)
A30808-X3247-B349-1-7630    BS11 – 7Installation TestBase Transceiver Station Equipment ITMN: BTSE BS111.3.3 Technical DataTechnical Data are listed in Tab. 1.11.3.4 Power Supply CheckVerify the presence of the power supply voltage and that its value is 230 VAC – 50 Hz or 110 VAC – 60 Hz.1.3.5 Grounding CheckMeasure the ground resistance value between the grounding screw placed on the BTSE and the grounding system ground plate.  The resistance value must be less than or equal to 5W.1.3.6 PCM CheckVerify the presence of the PCM flux and, if necessary, remove the line terminators or disconnecting switches present in the junction box.1.3.7 RF Cables Check (only in case of external antenna)Verify that the antenna and cable VSWR is less than 1.5.1.3.8 FusesFour fuses are mounted in the connection panel. Their functions are listed in Tab. 1.2.OBJECT BS-11 i/900.1 BS-11 e/900.1Weight ~ 23 kg ~ 23 kgVolume 0,5x0,45x0,13 (mm) 0,5x0,45x0,13 (mm)Input AC Power 83 ÷ 265 Vac 83 ÷ 265 VacWatts 80W 250WOperating temperature -45° to +45°C -45° to +45°CFrequency uplink 880-915 MHz 880-915 MHzFrequency downlink 925-960 MHz 925-960 MHzTRX_max per rack 1 1TRX_max per microcell 1 1Antenna Internal ExternalTX Power M1, M2, M3 and 2W GSM Power ClassesM1, M2, M3 and 2W GSM Power ClassesTab. 1.3.1  Technical Data: BS-11i and BS-11e
BS11 – 8 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment1.4 Abis InterfaceThe BTSE is pre-set with 120 Ohm impedance at the factory.It is possible, however, to change the impedance value and move it to 75 Ohm.Proceed as follows to change the impedance:– Open the connector panel cover, using the appropriate wrench supplied, to gain access to the panel.– Unscrew (Fig. 1.1.) the 4 screws (1) and remove the cover (2), thus gaining access to the protection circuit.– Unscrew the screw (1, Fig. 1.2.).– Lift up the protection circuit using the two handles (2, Fig. 1.2.).– Set the switches on the mini dip-switch SW3 Fig. 1.3.) as indicated in Tab. 1.1. (“75 Ohm impedance” column). The jumpers for the connection with 75 Ohm impedance are placed in the inner of the entry cables cover.Carry out the connections indicated in Fig. 1.2. on the T0B1 ÷ TB04 terminal board.FUSE TYPE FUNCTIONF1 10 A delayed Protects TRX0 power supplyF2 10 A delayed Protects TRX0 power supplyF3 10 A delayed Protects TRX1 power supplyF4 10 A delayed Protects TRX1 power supplyTab. 1.2 FusesDIP-SWITCH 75 Ohm IMPEDANCE 120 Ohm IMPEDANCE1CO2CO3CO4CO5OC6OC7OC8OCTab. 1.1 SW3 dip-switch configuration
A30808-X3247-B349-1-7630    BS11 – 9Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11Fig. 1.1 Connection panel (for external antenna)TERMINAL BOARD 75 Ohm IMPEDANCE 120 Ohm IMPEDANCETB01 2-3 NO JUMPERTB02 2-3 NO JUMPERTB03 2-3 NO JUMPERTB04 2-3 NO JUMPERTab. 1.2 TB01 ÷ TB04 configuration
BS11 – 10 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station EquipmentFig. 1.2 Protection circuitpin 1 pin 3 pin 5 pin 5pin 4 pin 6 pin 8pin 2pinning of J01 and J022
A30808-X3247-B349-1-7630    BS11 – 11Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11Fig. 1.4.3  SW3 /The black square stands for toggle) and TB01 ÷ TB04– Set the protection circuit in its slot making sure that the plastic handles do not go between the connector pins.– Place the protection circuit cover in position and tighten the 4 fastening screws.– Close the connector panel cover with the appropriate wrench.
BS11 – 12 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment1.5 Preparation for Offline TestsThe purpose of this chapter is to execute all commissioning activities forchecking the delivery quality and quantity of the BTSE on site.The following steps have to be executed to start the system:1. Obtain the recommended test and test equipment2. Preparation of the test and test equipment3. BTSE power on4.Start of LMT5. Download of the Safety SW6. Creation of HW related MO7. Set attributes for BTSE8. Offline testsFinally all documents must be filled in and all activities must be confirmed by the customer.1.5.1 Recommended Test Equipment and ToolsSeveral devices, instruments, accessories and utensils have to be provided and prepared for commisioning on site.1.5.1.1 Test equipmentThe equipment listed below has to be present for call simulation and verification of correct operation.SBS Abis Simulator-HW:- Portable PC min.80386DX, 16Bit AT, 4 MByte RAM- 120MByte HD- VGA/SVGA 640x480 Monitor-Mouse- 2x serial IF- 1x parallel IF, 1hour Battery Time- Full-Size Expansion Slot for MA-10 Card
A30808-X3247-B349-1-7630    BS11 – 13Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11Local Maintenance Terminal LMTSpectrum Analyser HP 8594A/EMS_BS RF Coupling BOX- SW: MA-10 Base Package, Abis application- Cable: 120Ω-MA10-Card<->Abis-75Ω-MA10-Card<->Abis-HW:- Portable PC min.80386DX, 16Bit AT, 4 MByte RAM- 120MByte HD- VGA/SVGA 640x480 Monitor-Mouse- 2x serial IF- 1x parallel IF, 1hour Battery Time- Full-Size Expansion Slot for V.11-IF->EICON-CARD:X.21-Level1/LAPB-Level2-SW:- MS-DOS-5.0 or higher- OSI-Gateway-V3R1- LMT Version:see actual SW Release Note- Virus Scanner e.g. McAFEE-V117- Cable: 15-PIN (NE) - 26PIN (LMT)-HW:- HP8594A/E- Option:004/010/021/101/102/105-SW:- GSM: HP 85715B Personality Card- DCS: HP 85722B Personality Card- Cable:- BNC_male-SMA_male: e.g.RG58- Adapter:- N_male-BNC_female-HW:- MS_BS-Coupling-Box (RF)- Cable:- BNC_male-BNC_male (MS)- 3x:7/16_male-N_male (RX/TX)- Adapter:- 7/16_male-N_male- Tool:
BS11 – 14 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station EquipmentMobile Station MSMultimeter1.5.1.2 ToolsSpecial tools for commissioning activities on site are listed below.IC Extraction ToolsAntistatic Setfor ESD Module HandlingSMA Toolfor Semi-rigid Cable ConnectorsSMC Toolfor Semi-rigid Cable ConnectorsSemi Rigid Bending Toolfor Semi rigid cable connectionTDMA Measuring Tools (Tests with HP 8594A/E) and Trigger Adapter- Absorber 20dB/25Watt-50 Ω Termination N_male-HW:-GSM-P1- GSM-S1 +CarKitGSM-S3 +CarKit- DCS-PT-11+CarKitDCS Mercury one-to-one plus Car Kit-SW:- Tracer SW-P1- Test-SIM- Test Plug-In SIM-HW:- SIEMENS Multimeter- IC-Extraction Tool for DIL-EPROM-IC-Extraction Tool for PLCC-HW:- 2 Measuring cable with BNC-Plugs male (sufficient length)- Adapter SMC male - BNC female- Trigger adapter for TAD at MCLK or LI(50-pins AMP-Plug with 2 x BNC-Plug female )- 2 Adapter N-Connector male - BNC female
A30808-X3247-B349-1-7630    BS11 – 15Installation TestBase Transceiver Station Equipment ITMN: BTSE BS111.5.2 Preparation and Presetting of Test Equipment1.5.2.1 Test equipmentFor minimum test time and correct test results the deviceshave to be prepared on site.Spectrum Analyzer1.5.2.2 Software (SW)For all tests only released SW (corresponding to the BTSE HW/SW release) is allowed to be running on the test equipment (TE).1.5.2.3 Boot Software/Firmware (SW/FW)For all tests only the released SW is allowed to be running on the BTSE corresponding to the BTSE HW/SW/FW release/revision.1.5.3 Connections– Open the connector panel cover, using the appropriate wrench supplied, to gain access to the panel itself (Fig. 1.1.).– Unscrew the 4 screws (1) and remove the cover (2), to gain access to connector J02 (Fig. 1.2.).1.5.4 BTSE Power ON1.5.4.1 Power OnPower the BTSE by setting the ON/OFF switch to ON.- HP 8590 series spectrum analyser operating manual- User´s Guide HP85715B GSM900 Transmitter Measurement Personality- User´s Guide HP 85722B DCS1800 Transmitter Measurement Personality- HW: the HP8594A/E needs a warm-up time of 20 minutes depending on the available options.The display shows "OVEN COLD" during the heating phase. Afterwards a CALIBRATION has to be carried out for defined measurement execution.- SW: The SW of GSM/DCS card has to be installed in advance.- Cable: For special tests, e.g."Power versus Time" a BNC loop at the backplane has to be provided:GATE-OUTPUT(TTL) to EXTERN TRIGGER INPUTThe cable from CCLK(TAD) to GATE-INPUT(TTL)for TDMA-FRAME Trigger has to be connected.See analyzer operating manual for more detailed information.NOTE: After having disconnected the power from the BTSE, it is necessary to wait a couple of seconds before powering it.
BS11 – 16 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment1.5.4.2 LED IndicationThe SL01 LED on the connector panel must be illuminated with green light.  This means that the BTSE is connected to the network.
A30808-X3247-B349-1-7630    IN – 17Installation TestBase Transceiver Station Equipment ITMN: BTSE BS112 Software Download and Activation1.  Switch on power of BS112.  Activate LMT and Login as Administrator and Enter the PASSWORD (default=admin)3. a. MBTS Phase 1: Warm upb. MBTS Phase 2: Normal (after a few minutes)4. Download of safety SWSoftware -->Download-->Browse:(the Download window appears)select the file btsbmcXX.swi(XX=version numbe)r-->ok-->start Downloadwait about 15’- after Download:--> Cancel (100% readed)- after 1’: LMT shows:MBTS Phase: 1 Load SMU SAFETYwait about 5’5. Creation of the objects:LMT-window shows MBTS Phase: 2 wait Min Config- LI-->Create Obj: select desired properties-->Send-->o.k.- GPSU-->Create Obj-->send-->o.k.- ALCO-->Create Obj-->send-->o.k.- CCLK-->Create Obj-->send-->o.k.- BTSU-->SET Attributes: select desired properties-->send-->o.k.-->can-cel- BBSIG 0-->Create Obj-->use default properties-->send-->o.k.- PA_0-->Create Obj-->select desired properties-->send-->o.k.6. Configuration-->Get Attribute-->E.S.N: if error message appears-->go:step 7, if not: step 9-->Get Attribute-->CALIBRATION: if error message appears-->go:step XY, if not: step YY7.  Logoff-->Logon-->Factory-->E.S.N.: enter values according to the BS11 label135 - 2044 / 02. . 07Code SequenceNumberEditionNum-berVersionNum-ber+Serial-Number-->send-->o.k.-->cancel
IN – 18 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment8. Configuration-->SET Attributes-->Calibration: enter forChain 1: 0Chain 2: 0PLL Calibration: 1024Antenna Type: External or Internal-->send-->o.k.-->cancel9. LMT window:MBTS phase: Load from BSCIf the connection between BS11 and BSC already exists and the BTSU parame-ters are stored in the BSC (TEI...)an automatic download from BSC to BTSE is startedif not: -->1010. Download from LMT- Operator Access-->Logoff-->Logon-->Administrator:Password- Software-->Download-->Browse:-->select the desired SW-Load Header- o.k.-->start Downloadwait about 15’- after Download: Cancel (100% reached)after 1’: LMT shows:MBTS Phase: 1 Load SMU SAFETYwait about 5’
A30808-X3247-B349-1-7630    BS11 – 19Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113 Execution of Offline Tests3.1 RF and Function Tests3.1.1 Purpose of the Abis Simulation on the MA-10 CardThe Mobile Radio Analyzer MA-10 is used for offline functional tests on site.A database download has to be done with the MA-10 after succesfull creation of HW related objects.The DB download allows to execute two test procedures:1. BERT test with MS loop.2. Voice test with MA-10 loop.3.1.2 Preparation of the Abis SimulationThe Abis Simulation contains a MA-10 Card with SW on disk and theapplication SW Abis Simulation Ext. SIEMENS. The SW requires a DOScomputer with WINDOWS 3.X.The MA-10 has to be installed and tested in advance,according to the Installation Manual BN 3032/98.80(W&G). In addition refer to the Operating Manual BN 3032/94.08(W&G)of Abis Simulation Ext. SIEMENS.The neccessary cable for the connetion to the BTSE Abis interfacehas to be provided.The IMSI of TestSim, which will be used for the MS, has to be entered in "SAG.INI" -File (one of the ABIS SIMULATION EXT.SIEMENS files) in advance.Note: See also additional information in the help menue of the simulator.3.1.3 Connection of Test equipment (TE)To achieve reliable measurement results the connections must be plugged correctly and faultless contact must be guaranteed.The complete equipment has to be connected in the following order:1. Attenuator (20dB/25W) to HYCOM/DUCOM/DUKIT(ANT)2. HYCOM/DUCOM/DUKIT (Test) to RF-(Connection-)Box(Test)3. RF-Box(RXAMOD/RXAMCO) to RXAMOD/RXAMCO (RFin)4. RXAMOD(RFout) to RCAP(RX0-5)(with specific attenuation)RXAMCO (out) to TPU (in)5. MS to RF-Box(MS)6. MA-10 Card to RCAP/OVPT-Abis
BS11 – 20 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment3.1.4 Check BTSE PhaseBefore you start the Abis Simulation check the phase of the BTSE at the LMT. It must be in Phase three.
A30808-X3247-B349-1-7630    BS11 – 21Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.2 Start of Abis Simulation1Start MA-10 controlWINDOWS has to be started first before the MA-10 is started.The start of Abis Simulation requires the start of MA-10 Control.The HW and SW performs the necessary boot procedure automatically.bClick on the MA-10 Control iconSIEMENSAbisSim Application StartThe ABIS SIMULATION EXT SIEMENS Window appears.SIEMENSAbisSim Phase x (Select from application field).2Load Test FileThe released test sequence has to be loaded.bFileLoad Test File... <select File (bts_down.tes)> OKWait a few seconds for the loading procedure to finish (the icons get some colours).Choose released sequencefile ......tes.3Configuration MA-10The additional Abis parameters have to be set.bConfigurationMA-10...Line interface...<select: Clock: derived from signalImpedance: terminated CRC-4: on/off must be set as created in the BTSE> OK
BS11 – 22 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4Configuration simulatorThe current TestSim IMSI for the mobile station corresponding to the system standard GSM 900/DCS 1800 and the customer has to be choosen.Only the TestSim IMSI that has been entered in the "SAG.INI" file can be choosen.bConfigurationCall Parameter...<select IMSI and TCH type>ApplyCloseNow the MA-10 is ready for the data base download procedure.5Configuration of the BTSE-typeThe special BTSE parameters have to be set.bConfigurationBTS Equipment....BTSE < select:  Network Type, No. of BTS and TRX>Signalling< select: Sign. channel type and BTSM as created in BTSE>ApplyClose6Configuration of BCCHThe network codes  have to be entered.bConfigurationBCCH Info...LAC/CI< Enter the corresponding network codes>ApplyClose
A30808-X3247-B349-1-7630    BS11 – 23Installation TestBase Transceiver Station Equipment ITMN: BTSE BS117Set site specific test parameterAdditionally parameter set for current site configuration will be performed.bDatabaseEdit<select or enter the desired paramenters for:BTS Side Manager, Power Control, Cells,.........>OKNow the Interactive Editor Window shows the available parameters which can be set depending on the configuration data.Select proper menues and param-eter valuesTypical Parameter which might be set (depending on the configuration):Abis-Parameter:1. BTSM_PCMSlot (set identically to configuration data (LMT))2. BTSM_Tei (set identically to configuration data (LMT))Um-Parameter:3. Frequencies4. NumBTS5. NumTRX6. BCCH_TRX7. MsTxPowerMax8.TXMaxPowerRed_BTSCountry/SIM-Parameter:9. MobileCountryCode (see TestSim IMSI)10. MobileNetworkCode (see TestSIM IMSI)11. LocationAreaID8Start of SimulationbTestStartEND
BS11 – 24 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 25Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.3 Database download1Start of Database downloadExecution of database download.bTestStartOKThe MA-10 SW performs the boot and download procedure.The Log-Output [xxx.sqz] window appears.Check for correct parameter setting2Restart of Test SequencebStart (Wait approximately 20 s)OKOKThe DB-Alignment window appears after about 20 seconds.Afterwards the system information window will appear .After the alignement procedure the SPA-LED at TPU and SPA-LED at BBSIG are flashing.END
BS11 – 26 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 27Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.4 Call check with MA-10-LoopThis test provides a loop check via the MS.The MA-10 performs a MTC. The loop back can be heard with a delay of a few seconds after the connection to the MS has been established.1MA-10 Loop ConfigurationbConfigurationMeasurementselect: Measurement mode = TCH Loop - desired parametersApplyClose2Start TestbTestStart3Stop TestbTestStopEND
BS11 – 28 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 29Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.5 Bit Error Rate (BERT) Test with MS-LoopThis test provides a BERT Test available on every equipped TRX and timeslot.The MA-10 performs a MTC.After establishment of the connection to the MSwith the TestSim, the loop into the MS allows the decoding of sent messages.1BERTbConfigurationMeasurementselect:- Measurement mode = BERT MS Loop- desired parametersApplyClose2Start TestbTestStartEND
BS11 – 30 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 31Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.6 Settings at HP 8594ASome additional RF-Measurements with the Spectrum Analyser (here HP 8594A) are useful to check the BTSE-Function.Start the Abis-Simulation and check the SW-Card (Plug in Card, HP 85715B GSM 900 Measurements Personality Card or HP 85722 DCS 1800 Measurements Personality Card) before measurements are executed.After the warm-up-phase of the spectrum analyser startthe  self-calibration routine. Approximately 15 minutes later disappeares the "OVEN COLD" message from screen.The following blocks show four tests (select from HP-Menu with Key or Soft-Keys):1Carrier PowerTRIGEXTERNALMODEDCS 1800/GSM AnalyserPhysical ChannelAuto FunctionAuto ARFCNMODEDCS 1800/GSM AnalyserPowerCarrier PowerResult: Mean TXRX Power in dBm.2P vs T FrameTRIGEXTERNALMODEDCS 1800/GSM AnalyserPhysical ChannelAuto FunctionAuto ARFCNMODEDCS 1800/GSM AnalyserPower vs TimeP vs T FrameResult: Limit Pass or Limit Fail
BS11 – 32 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment3P vs T TimeslotTRIGEXTERNALMODEDCS 1800/GSM AnalyserPhysical ChannelAuto FunctionAuto ARFCNMODEDCS 1800/GSM AnalyserPower vs TimeP vs T TimeslotResult: Limit Pass or Limit Fail4Output of spectrum switching transientsTRIGEXTERNALMODEDCS 1800/GSM AnalyserPhysical Channel Auto FunctionAuto ARFCNMODEDCS 1800/GSM AnalyserOut RF SpectrumRF Spect TransientTransient SweptResult: Limit Pass or Limit FailFor more details about RF-Measurements read HP User Guide.END
A30808-X3247-B349-1-7630    BS11 – 33Installation TestBase Transceiver Station Equipment ITMN: BTSE BS113.7 RFI-Confirmation: Unit ATMNAll commissioning tasks on site for providing successful integration have to be confirmed in the ATMN:BTSE.
BS11 – 34 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment
A30808-X3247-B349-1-7630    BS11 – 35Installation TestBase Transceiver Station Equipment ITMN: BTSE BS114 Appendix4.1 Frequency/Channel Conversion Table4.1.1 GSM TableFrequency-Band Quantity NumberGSM: 935-960890-915=>124 001 ... 124E-GSM: 925-960880-915=>174 975 ... 1023DCS 1800: 1805-18801710-1785=>374 512 ... 885PCS 1900: 1930-19901850-1910=>299 512 ... 810Tab. 4.1 Frequency/Channel Conversion TableARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink Downlink1 890,20 935,20 41 898,20 943,20 81 906,20 951,202 890,40 935,40 42 898,40 943,40 82 906,40 951,403 890,60 935,60 43 898,60 943,60 83 906,60 951,604 890,80 935,80 44 898,80 943,80 84 906,80 951,805 891,00 936,00 45 899,00 944,00 85 907,00 952,006 891,20 936,20 46 899,20 944,20 86 907,20 952,207 891,40 936,40 47 899,40 944,40 87 907,40 952,408 891,60 936,60 48 899,60 944,60 88 907,60 952,609 891,80 936,80 49 899,80 944,80 89 907,80 952,8010 892,00 937,00 50 900,00 945,00 90 908,00 953,0011 892,20 937,20 51 900,20 945,20 91 908,20 953,2012 892,40 937,40 52 900,40 945,40 92 908,40 953,4013 892,60 937,60 53 900,60 945,60 93 908,60 953,6014 892,80 937,80 54 900,80 945,80 94 908,80 953,8015 893,00 938,00 55 901,00 946,00 95 909,00 954,0016 893,20 938,20 56 901,20 946,20 96 909,20 954,20Tab. 4.2 GSM Table
BS11 – 36 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment17 893,40 938,40 57 901,40 946,40 97 909,40 954,4018 893,60 938,60 58 901,60 946,60 98 909,60 954,6019 893,80 938,80 59 901,80 946,80 99 909,80 954,8020 894,00 939,00 60 902,00 947,00 100 910,00 955,0021 894,20 939,20 61 902,20 947,20 101 910,20 955,2022 894,40 939,40 62 902,40 947,40 102 910,40 955,4023 894,60 939,60 63 902,60 947,60 103 910,60 955,6024 894,80 939,80 64 902,80 947,80 104 910,80 955,8025 895,00 940,00 65 903,00 948,00 105 911,00 956,0026 895,20 940,20 66 903,20 948,20 106 911,20 956,2027 895,40 940,40 67 903,40 948,40 107 911,40 956,4028 895,60 940,60 68 903,60 948,60 108 911,60 956,6029 895,80 940,80 69 903,80 948,80 109 911,80 956,8030 896,00 941,00 70 904,00 949,00 110 912,00 957,0031 896,20 941,20 71 904,20 949,20 111 912,20 957,2032 896,40 941,40 72 904,40 949,40 112 912,40 957,4033 896,60 941,60 73 904,60 949,60 113 912,60 957,6034 896,80 941,80 74 904,80 949,80 114 912,80 957,8035 897,00 942,00 75 905,00 950,00 115 913,00 958,0036 897,20 942,20 76 905,20 950,20 116 913,20 958,2037 897,40 942,40 77 905,40 950,40 117 913,40 958,4038 897,60 942,60 78 905,60 950,60 118 913,60 958,6039 897,80 942,80 79 905,80 950,80 119 913,80 958,8040 898,00 943,00 80 906,00 951,00 120 914,00 959,00------ ------ ------ ------ ------ ------ 121 914,20 959,20------ ------ ------ ------ ------ ------ 122 914,40 959,40------ ------ ------ ------ ------ ------ 123 914,60 959,60------ ------ ------ ------ ------ ------ 124 914,80 959,80ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink DownlinkTab. 4.2 GSM Table
A30808-X3247-B349-1-7630    BS11 – 37Installation TestBase Transceiver Station Equipment ITMN: BTSE BS114.1.2 E GSM TableARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink975 880,20 925,20 1000 885,20 930,20976 880,40 925,40 1001 885,40 930,40977 880,60 925,60 1002 885,60 930,60978 880,80 925,80 1003 885,80 930,80979 881,00 926,00 1004 886,00 931,00980 881,20 926,20 1005 886,20 931,20981 881,40 926,40 1006 886,40 931,40982 881,60 926,60 1007 886,60 931,60983 881,80 926,80 1008 886,80 931,80984 882,00 927,00 1009 887,00 932,00985 882,20 927,20 1010 887,20 932,20986 882,40 927,40 1011 887,40 932,40987 882,60 927,60 1012 887,60 932,60988 882,80 927,80 1013 887,80 932,80989 883,00 928,00 1014 888,00 933,00990 883,20 928,20 1015 888,20 933,20991 883,40 928,40 1016 888,40 933,40992 883,60 928,60 1017 888,60 933,60993 883,80 928,80 1018 888,80 933,80994 884,00 929,00 1019 889,00 934,00995 884,20 929,20 1020 889,20 934,20996 884,40 929,40 1021 889,40 934,40997 884,60 929,60 1022 889,60 934,60998 884,80 929,80 1023 889,80 934,80999 885,00 930,00 ----- ----- -----Tab. 4.3 E-GSM Table
BS11 – 38 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4.1.3 DCS Table4.1.3.1 DCS Table Part 1/3ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Down-link Uplink Down-link Uplink Down-link512 1710,2 1805,2 549 1717,6 1812,6 586 1725 1820513 1710,4 1805,4 550 1717,8 1812,8 587 1725,2 1820,2514 1710,6 1805,6 551 1718 1813 588 1725,4 1820,4515 1710,8 1805,8 552 1718,2 1813,2 589 1725,6 1820,6516 1711 1806 553 1718,4 1813,4 590 1725,8 1820,8517 1711,2 1806,2 554 1718,6 1813,6 591 1726 1821518 1711,4 1806,4 555 1718,8 1813,8 592 1726,2 1821,2519 1711,6 1806,6 556 1719 1814 593 1726,4 1821,4520 1711,8 1806,8 557 1719,2 1814,2 594 1726,6 1821,6521 1712 1807 558 1719,4 1814,4 595 1726,8 1821,8522 1712,2 1807,2 559 1719,6 1814,6 596 1727 1822523 1712,4 1807,4 560 1719,8 1814,8 597 1727,2 1822,2524 1712,6 1807,6 561 1720 1815 598 1727,4 1822,4525 1712,8 1807,8 562 1720,2 1815,2 599 1727,6 1822,6526 1713 1808 563 1720,4 1815,4 600 1727,8 1822,8527 1713,2 1808,2 564 1720,6 1815,6 601 1728 1823528 1713,4 1808,4 565 1720,8 1815,8 602 1728,2 1823,2529 1713,6 1808,6 566 1721 1816 603 1728,4 1823,4530 1713,8 1808,8 567 1721,2 1816,2 604 1728,6 1823,6531 1714 1809 568 1721,4 1816,4 605 1728,8 1823,8532 1714,2 1809,2 569 1721,6 1816,6 606 1729 1824533 1714,4 1809,4 570 1721,8 1816,8 607 1729,2 1824,2534 1714,6 1809,6 571 1722 1817 608 1729,4 1824,4535 1714,8 1809,8 572 1722,2 1817,2 609 1729,6 1824,6536 1715 1810 573 1722,4 1817,4 610 1729,8 1824,8537 1715,2 1810,2 574 1722,6 1817,6 611 1730 1825538 1715,4 1810,4 575 1722,8 1817,8 612 1730,2 1825,2539 1715,6 1810,6 576 1723 1818 613 1730,4 1825,4540 1715,8 1810,8 577 1723,2 1818,2 614 1730,6 1825,6Tab. 4.1.4  DCS Part 1/3
A30808-X3247-B349-1-7630    BS11 – 39Installation TestBase Transceiver Station Equipment ITMN: BTSE BS114.1.3.2 DCS Table Part 2/3541 1716 1811 578 1723,4 1818,4 615 1730,8 1825,8542 1716,2 1811,2 579 1723,6 1818,6 616 1731 1826543 1716,4 1811,4 580 1723,8 1818,8 617 1731,2 1826,2544 1716,6 1811,6 581 1724 1819 618 1731,4 1826,4545 1716,8 1811,8 582 1724,2 1819,2 619 1731,6 1826,6546 1717 1812 583 1724,4 1819,4 620 1731,8 1826,8547 1717,2 1812,2 584 1724,6 1819,6 621 1732 1827548 1717,4 1812,4 585 1724,8 1819,8 622 1732,2 1827,2ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Down-link Uplink Down-link Uplink Down-link623 1732,4 1827,4 660 1739,8 1834,8 697 1747,2 1842,2624 1732,6 1827,6 661 1740 1835 698 1747,4 1842,4625 1732,8 1827,8 662 1740,2 1835,2 699 1747,6 1842,6626 1733 1828 663 1740,4 1835,4 700 1747,8 1842,8627 1733,2 1828,2 664 1740,6 1835,6 701 1748 1843628 1733,4 1828,4 665 1740,8 1835,8 702 1748,2 1843,2629 1733,6 1828,6 666 1741 1836 703 1748,4 1843,4630 1733,8 1828,8 667 1741,2 1836,2 704 1748,6 1843,6631 1734 1829 668 1741,4 1836,4 705 1748,8 1843,8632 1734,2 1829,2 669 1741,6 1836,6 706 1749 1844633 1734,4 1829,4 670 1741,8 1836,8 707 1749,2 1844,2634 1734,6 1829,6 671 1742 1837 708 1749,4 1844,4635 1734,8 1829,8 672 1742,2 1837,2 709 1749,6 1844,6636 1735 1830 673 1742,4 1837,4 710 1749,8 1844,8637 1735,2 1830,2 674 1742,6 1837,6 711 1750 1845638 1735,4 1830,4 675 1742,8 1837,8 712 1750,2 1845,2639 1735,6 1830,6 676 1743 1838 713 1750,4 1845,4Tab. 4.1.5  DCS Part 2/3ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Down-link Uplink Down-link Uplink Down-linkTab. 4.1.4  DCS Part 1/3
BS11 – 40 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4.1.3.3 DCS Table Part 3/3640 1735,8 1830,8 677 1743,2 1838,2 714 1750,6 1845,6641 1736 1831 678 1743,4 1838,4 715 1750,8 1845,8642 1736,2 1831,2 679 1743,6 1838,6 716 1751 1846643 1736,4 1831,4 680 1743,8 1838,8 717 1751,2 1846,2644 1736,6 1831,6 681 1744 1839 718 1751,4 1846,4646 1737 1832 683 1744,4 1839,4 720 1751,8 1846,8647 1737,2 1832,2 684 1744,6 1839,6 721 1752 1847648 1737,4 1832,4 685 1744,8 1839,8 722 1752,2 1847,2649 1737,6 1832,6 686 1745 1840 723 1752,4 1847,4650 1737,8 1832,8 687 1745,2 1840,2 724 1752,6 1847,6651 1738 1833 688 1745,4 1840,4 725 1752,8 1847,8652 1738,2 1833,2 689 1745,6 1840,6 726 1753 1848653 1738,4 1833,4 690 1745,8 1840,8 727 1753,2 1848,2654 1738,6 1833,6 691 1746 1841 728 1753,4 1848,4655 1738,8 1833,8 692 1746,2 1841,2 729 1753,6 1848,6656 1739 1834 693 1746,4 1841,4 730 1753,8 1848,8657 1739,2 1834,2 694 1746,6 1841,6 731 1754 1849658 1739,4 1834,4 695 1746,8 1841,8 732 1754,2 1849,2659 1739,6 1834,6 696 1747 1842 733 1754,4 1849,4ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink Downlink734 1754,6 1849,6 770 1761,8 1856,8 806 1769 1864735 1754,8 1849,8 771 1762 1857 807 1769,2 1864,2736 1755 1850 772 1762,2 1857,2 808 1769,4 1864,4737 1755,2 1850,2 773 1762,4 1857,4 809 1769,6 1864,6738 1755,4 1850,4 774 1762,6 1857,6 810 1769,8 1864,8739 1755,6 1850,6 775 1762,8 1857,8 811 1770 1865740 1755,8 1850,8 776 1763 1858 812 1770,2 1865,2Tab. 4.1.6  DCS Part 3/3ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Down-link Uplink Down-link Uplink Down-linkTab. 4.1.5  DCS Part 2/3
A30808-X3247-B349-1-7630    BS11 – 41Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11741 1756 1851 777 1763,2 1858,2 813 1770,4 1865,4742 1756,2 1851,2 778 1763,4 1858,4 814 1770,6 1865,6743 1756,4 1851,4 779 1763,6 1858,6 815 1770,8 1865,8744 1756,6 1851,6 780 1763,8 1858,8 816 1771 1866745 1756,8 1851,8 781 1764 1859 817 1771,2 1866,2746 1757 1852 782 1764,2 1859,2 818 1771,4 1866,4747 1757,2 1852,2 783 1764,4 1859,4 819 1771,6 1866,6748 1757,4 1852,4 784 1764,6 1859,6 820 1771,8 1866,8749 1757,6 1852,6 785 1764,8 1859,8 821 1772 1867750 1757,8 1852,8 786 1765 1860 822 1772,2 1867,2751 1758 1853 787 1765,2 1860,2 823 1772,4 1867,4752 1758,2 1853,2 788 1765,4 1860,4 824 1772,6 1867,6753 1758,4 1853,4 789 1765,6 1860,6 825 1772,8 1867,8754 1758,6 1853,6 790 1765,8 1860,8 826 1773 1868755 1758,8 1853,8 791 1766 1861 827 1773,2 1868,2756 1759 1854 792 1766,2 1861,2 828 1773,4 1868,4757 1759,2 1854,2 793 1766,4 1861,4 829 1773,6 1868,6758 1759,4 1854,4 794 1766,6 1861,6 830 1773,8 1868,8759 1759,6 1854,6 795 1766,8 1861,8 831 1774 1869760 1759,8 1854,8 796 1767 1862 832 1774,2 1869,2761 1760 1855 797 1767,2 1862,2 833 1774,4 1869,4762 1760,2 1855,2 798 1767,4 1862,4 834 1774,6 1869,6763 1760,4 1855,4 799 1767,6 1862,6 835 1774,8 1869,8764 1760,6 1855,6 800 1767,8 1862,8 836 1775 1870765 1760,8 1855,8 801 1768 1863 837 1775,2 1870,2766 1761 1856 802 1768,2 1863,2 838 1775,4 1870,4767 1761,2 1856,2 803 1768,4 1863,4 839 1775,6 1870,6768 1761,4 1856,4 804 1768,6 1863,6 840 1775,8 1870,8769 1761,6 1856,6 805 1768,8 1863,8 841 1776 1871ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink DownlinkTab. 4.1.6  DCS Part 3/3
BS11 – 42 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4.1.4 PCS Table4.1.4.1 PCS Table Part 14.1.4.2 PCS Table Part 2ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink Downlink842 1776,2 1871,2 857 1779,2 1874,2 872 1782,2 1877,2843 1776,4 1871,4 858 1779,4 1874,4 873 1782,4 1877,4844 1776,6 1871,6 859 1779,6 1874,6 874 1782,6 1877,6845 1776,8 1871,8 860 1779,8 1874,8 875 1782,8 1877,8846 1777 1872 861 1780 1875 876 1783 1878847 1777,2 1872,2 862 1780,2 1875,2 877 1783,2 1878,2848 1777,4 1872,4 863 1780,4 1875,4 878 1783,4 1878,4849 1777,6 1872,6 864 1780,6 1875,6 879 1783,6 1878,6850 1777,8 1872,8 865 1780,8 1875,8 880 1783,8 1878,8851 1778 1873 866 1781 1876 881 1784 1879852 1778,2 1873,2 867 1781,2 1876,2 882 1784,2 1879,2853 1778,4 1873,4 868 1781,4 1876,4 883 1784,4 1879,4854 1778,6 1873,6 869 1781,6 1876,6 884 1784,6 1879,6855 1778,8 1873,8 870 1781,8 1876,8 885 1784,8 1879,8856 1779 1874 871 1782 1877Tab. 4.1.7  PCS Part 1/3ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink Downlink629 1873,6 1953,6 668 1881,4 1961,4 707 1889,2 1969,2630 1873,8 1953,8 669 1881,6 1961,6 708 1889,4 1969,4631 1874 1954 670 1881,8 1961,8 709 1889,6 1969,6632 1874,2 1954,2 671 1882 1962 710 1889,8 1969,8633 1874,4 1954,4 672 1882,2 1962,2 711 1890 1970634 1874,6 1954,6 673 1882,4 1962,4 712 1890,2 1970,2635 1874,8 1954,8 674 1882,6 1962,6 713 1890,4 1970,4636 1875 1955 675 1882,8 1962,8 714 1890,6 1970,6Tab. 4.8 PCS Part 2/3
A30808-X3247-B349-1-7630    BS11 – 43Installation TestBase Transceiver Station Equipment ITMN: BTSE BS11637 1875,2 1955,2 676 1883 1963 715 1890,8 1970,8638 1875,4 1955,4 677 1883,2 1963,2 716 1891 1971639 1875,6 1955,6 678 1883,4 1963,4 717 1889,2 1971,2640 1875,8 1955,8 679 1883,6 1963,6 718 1889,4 1971,4641 1876 1956 680 1883,8 1963,8 719 1889,6 1971,6642 1876,2 1956,2 681 1884 1964 720 1889,8 1971,8643 1876,4 1956,4 682 1884,2 1964,2 721 1890 1972644 1876,6 1956,6 683 1884,4 1964,4 722 1890,2 1972,2645 1876,8 1956,8 684 1884,6 1964,6 723 1890,4 1972,4646 1877 1957 685 1884,8 1964,8 724 1892,6 1972,6647 1877,2 1957,2 686 1885 1965 725 1892,8 1972,8648 1877,4 1957,4 687 1885,2 1965,2 726 1893 1973649 1877,6 1957,6 688 1885,4 1965,4 727 1893,2 1973,2650 1877,8 1957,8 689 1885,6 1965,6 728 1893,4 1973,4651 1878 1958 690 1885,8 1965,8 729 1893,6 1973,6652 1878,2 1958,2 691 1886 1966 730 1893,8 1973,8653 1878,4 1958,4 692 1886,2 1966,2 731 1894 1974654 1878,6 1958,6 693 1886,4 1966,4 732 1894,2 1974,2655 1878,8 1958,8 694 1886,6 1966,6 733 1894,4 1974,4656 1879 1959 695 1886,8 1966,8 734 1894,6 1974,6657 1879,2 1959,2 696 1887 1967 735 1894,8 1974,8658 1879,4 1959,4 697 1887,2 1967,2 736 1895 1975659 1879,6 1959,6 698 1887,4 1967,4 737 1895,2 1975,2660 1879,8 1959,8 699 1887,6 1967,6 738 1895,4 1975,4661 1880 1960 700 1887,8 1967,8 739 1895,6 1975,6662 1880,2 1960,2 701 1888 1968 740 1895,8 1975,8663 1880,4 1960,4 702 1888,2 1968,2 741 1896 1976664 1880,6 1960,6 703 1888,4 1968,4 742 1896,2 1976,2665 1880,8 1960,8 704 1888,6 1968,6 743 1896,4 1976,4666 1881 1961 705 1888,8 1968,8 744 1896,6 1976,6667 1881,2 1961,2 706 1889 1969 745 1896,8 1976,8ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink DownlinkTab. 4.8 PCS Part 2/3
BS11 – 44 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4.1.4.3 PCS Table Part 3ARFCN Frequency (MHz) ARFCN Frequency (MHz) ARFCN Frequency (MHz)Uplink Downlink Uplink Downlink Uplink Downlink746 1897 1977 768 1901,4 1981,4 790 1905,8 1985,8747 1897,2 1977,2 769 1901,6 1981,6 791 1906 1986748 1897,4 1977,4 770 1901,8 1981,8 792 1906,2 1986,2749 1897,6 1977,6 771 1902 1982 793 1906,4 1986,4750 1897,8 1977,8 772 1902,2 1982,2 794 1906,6 1986,6751 1898 1978 773 1902,4 1982,4 795 1906,8 1986,8752 1898,2 1978,2 774 1902,6 1982,6 796 1907 1987753 1898,4 1978,4 775 1902,8 1982,8 797 1907,2 1987,2754 1898,6 1978,6 776 1903 1983 798 1907,4 1987,4755 1898,8 1978,8 777 1903,2 1983,2 799 1907,6 1987,6756 1899 1979 778 1903,4 1983,4 800 1907,8 1987,8757 1899,2 1979,2 779 1903,6 1983,6 801 1908 1988758 1899,4 1979,4 780 1903,8 1983,8 802 1908,2 1988,2759 1899,6 1979,6 781 1904 1984 803 1908,4 1988,4760 1899,8 1979,8 782 1904,2 1984,2 804 1908,6 1988,6761 1900 1980 783 1904,4 1984,4 805 1908,8 1988,8762 1900,2 1980,2 784 1904,6 1984,6 806 1909 1989763 1900,4 1980,4 785 1904,8 1984,8 807 1909,2 1989,2764 1900,6 1980,6 786 1905 1985 808 1909,4 1989,4765 1900,8 1980,8 787 1905,2 1985,2 809 1909,6 1989,6766 1901 1981 788 1905,4 1985,4 810 1909,8 1989,6767 1901,2 1981,2 789 1905,6 1985,6Tab. 4.9 PCS Part3/3
A30808-X3247-B349-1-7630    BS11 – 45Installation TestBase Transceiver Station Equipment ITMN: BTSE BS114.2 Binary-HEX-Decimal Table4.3 Power/Level ConversionThe formula for power calculation:Lp[dBm] = 10lg(Px/P0)Px[Watt] = 10-3 BINARY HEX DECIMAL0000 0 00001 1 10010 2 20011 3 30100 4 40101 5 50110 6 60111 7 71000 8 81001 9 91010 A 101011 B 111100 C 121101 D 131110 E 141111 F 15Tab. 4.1 Binary-HEX-Decimal TableLp[+dBm] Px[Watt]010-310 10-220 10-130 133 237 539 8Tab. 4.1 Power conversion table
BS11 – 46 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment4.4 Used Expressions40 1044 2546 4047 5050 100+ 3dB ≅factor 2+ 5dB ≅factor 3+10dB ≅factor 10-48V -48V for test adapter12V +12 Volt1ER-3 bit error rate >10-3 port 11ER-6 bit error rate > 10-6 port 11RAI remote alarm indication port 12RAI remote alarm indication port 22ER-3 bit error rate 10-3 port 22ER-6 bit error rate 10-6 port 25V +5 VoltLp[+dBm] Px[Watt]Tab. 4.1 Power conversion table
A30808-X3247-B349-1-7630    BS11 – 47Installation TestBase Transceiver Station Equipment ITMN: BTSE BS115 AbbreviationsACTAM acom+txamod=>HYCOM ARFCN absolute radio frequency channel number BCCH broadcast control channel BERT bit error ratio BTS base transceiver station BTSE base transceiver station equipment BTSM BTS site manager FW firmware HW hardware IMSI international mobile subscriber identity LAC local area code MO managed object MS mobile station MTC mobile terminating call NE network element O&M operation and maintenance SW software TAC technical assistance center TCH traffic channel TDMA time devision multiple access TE test equipment TEI terminal endpoint identifier UMN user manual
BS11 – 48 A30808-X3247-B349-1-7630ITMN: BTSE BS11 Installation TestBase Transceiver Station Equipment

Navigation menu