Nokia Solutions and Networks T5JX1 UBS CDMA XMI Transceiver at 800 MHz User Manual Exhibit 8e
Nokia Solutions and Networks UBS CDMA XMI Transceiver at 800 MHz Exhibit 8e
Contents
Exhibit 8e
Preparing the LMF Chapter 3: LMF Operation Figure 3-1 LMF Folder Structure ti-cdma-05823.eps The loads folder and all the folders below it are no longer contained on the LMF CD as of LMF 2.9.0.0. When installing LMF software on a system that has never contained LMF software before, the user will need to create these folders manually. When installing a new version of LMF onto a PC already containing LMF software, any existing folders will be unaffected. WinLMF Directory The CDMA LMF installation program creates the default home directory, c:\wlmf, and installs the application files and subdirectories (folders) in it. Because this can be changed at installation, the CDMA LMF home directory will be referred to with the generic convention of::\lmf home directory> Where: = the LMF computer drive letter where the CDMA LMF home directory is located. = the directory path or name where the CDMA LMF is installed. 3-4 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Preparing the LMF WinLMF Operating System Installation This section provides information and instructions for installing and updating the LMF software and files. First Time Installation Sequence: 1. Install Java Runtime Environment (JRE) 2. Install U/WIN K-shell emulator (optional) 3. Install LMF application programs Any time U/WIN is re-installed, the LMF application software must also be re-installed. This is because the LMF application installation modifies some of the files that are installed during the U/Win installation. These modifications are necessary for proper LMF CLI operation. If required, a separate CD ROM of UBS Binaries may be obtained for binary updates. First Time Installation Sequence Follow the procedure in Procedure 3-1 to install the LMF application program using the LMF CD ROM. Procedure 3-1 CD ROM Installation Insert the LMF Program CD ROM into the LMF CD ROM drive. • If the Setup screen appears, follow the instructions displayed on the screen. • If the Setup screen is not displayed, proceed to step 2. Click on the Start button. Select Run. Enter d:\autorun in the Open box and click OK. If applicable, replace the letter d with the correct CD ROM drive letter. 68P09283A63-5 3-5 FOA AUG 2007 LMF to UBS Connection Chapter 3: LMF Operation LMF to UBS Connection ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ LMF to UBS Connection Follow the procedure in Procedure 3-2 to establish LMF to UBS connection. Procedure 3-2 LMF to UBS Connection Procedure Verify that the WinLMF computer has an Ethernet port. Verify that a serial port (normally COM 1) is available for use. Connect CDMA LMF to the UBS via the CRMS/LMT Customer ENET or DMI LMT port. Figure 3-2 LMF Connection Detail COM1 Connector LMF NOTEBOOK RS-232 Null Modem Cable Ethernet Hub Ethernet Port To GPIB Box To CRMS / LMT CUSTOMER ENET Port or DMI LMT Port (if CRMS is in use) NOTE: The Ethernet hub is is used when the Ethernet interface on the LMF PC may not be able to keep a reliable ethernet link. ti-cdma-05842-A.eps 3-6 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Using WinLMF ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Basic WinLMF Operation LMF Coverage in This Publication — All references to the LMF in this publication are for the CDMA application program Operating Environments — The LMF application program allows the user to work in the two following operating environments which are accessed using the specified desktop icons: • Graphical User Interface (GUI) using the WinLMF with UBS Support icon • Command Line Interface (CLI) using the WinLMF CLI UBS icon CLI can be run if the GUI is already running. Basic Operation — The GUI is the primary optimization and acceptance testing operating environment. The CLI environment provides additional capability to the user to perform manually controlled acceptance tests and audit the results of optimization and calibration actions. Both operations allow the following: • Selecting and deselecting UBS devices • Unlocking devices • Locking devices • Resetting devices • Obtaining device status The following additional basic operation can be performed in a GUI environment: • Sorting a status report window • Displaying the Electronic Identification (EID) information of the FRUs For detailed information on performing these and other LMF operations, refer to the LMF On-Line Help. Unless otherwise noted, LMF procedures in this manual are performed using the GUI environment. 68P09283A63-5 3-7 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Online Help - Task oriented online help is available in the LMF by clicking on Help from the menu bar. The LMF Display and the UBS UBS Display - When the LMF is logged into a UBS, a frame tab is displayed. The frame tab will be labeled with Frame, the UBS number, a dash, and the frame number (for example, Frame-812-1 for UBS 812, RFMF 1). There is only one frame for the UBS, so there will only be one tab. Graphical User Interface Overview The LMF uses a Graphical User Interface (GUI), which supports the following functions: • Selecting a device or devices • Selecting an action to apply to selected device(s) • Status report window displaying progress of actions taking place and related information • Notification when an action is complete and related information such as indication of success or failure • An OK button to close the status report window. Understanding GUI Operation For detailed information on GUI operation and the LMF, refer to the LMF Help function on-line documentation. Command Line Interface Overview The LMF also provides Command Line Interface (CLI) capability. Activate the CLI by clicking on a shortcut icon on the desktop. The CLI can only be launched while the GUI is running. If the CLI tool was NOT installed, it is possible to telnet to the CLI without the UWIN tool by using the command line in windows (RUN-> cmd) and typing in the window after the LMF has already logged in: telnet localhost 9600 appset newline value=2 3-8 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF CLI Format Conventions The CLI command can be broken down in the following way: • verb • device including device identifier parameters • switch • option parameters keywords equal signs parameter values Spaces are required between the verb, device, switch, and option parameters. A hyphen is required between the device and its identifiers. The following is an example of a UBS CLI command: configure sc- - - pgain= mdm_slot= ce= [pnoffset= ] Refer to the WinLMF CDMA CLI Commands – 68P09275A12 manual for further information on CLI commands and their use. Logging into a UBS Logging into a UBS establishes a communications link between the UBS and the LMF. An LMF session can be logged into only one UBS at a time. Prerequisites Before attempting to login to a UBS, ensure the following have been completed: • The LMF is properly connected to the UBS (see Figure 3-2) • The LMF application program is correctly installed and prepared • Preparing the LMF for Connectivity and Configuring the Controller of UBS procedures are completed • The LMF computer was connected to the UBS before starting the Windows operating system and LMF software. If necessary, restart the computer after connecting it to the UBS in accordance with Procedure 3-3 and Figure 3-2. • When the PC has completed startup, click on WinLMF with UBS Support icon Figure 3-3 to bring up the Local Terminal window (Figure 3-4 ) • IP Address is 128.0.0.xxx • Netmask address is 255.255.255.128 • BlackICE or other similar process is disabled • Window Internet Connection Firewall and other firewall programs should be disabled • Java Runtime Environment (JRE) is installed and version matched 68P09283A63-5 3-9 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-3 WinLMF Icon ti-cdma-LMF_UBS_Supp ort.eps Figure 3-4 Local Terminal (Login Screen) ti-cdma-06193.eps 3-10 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF UBS Login from the GUI Environment Follow the procedure in Procedure 3-3 to log into a UBS when using the GUI environment. Procedure 3-3 UBS GUI Login Procedure The LMF computer Network Interface Card (NIC) IP address is set to 128.0.0.48, subnetmask 255.255.255.128. Ping UBS frame (128.0.0.2) from PC (128.0.0.48) Disable/Stop all rewalls and other applications (e.g. BlackICE) which may block UDP / TCP transfers. Disable all active FTP servers running on the PC. Terminate process called inetd.exe if it is running. NOTE: inetd32.exe may be active and doesn’t require termination Start the CDMA LMF GUI environment by double clicking on the WinLMF with UBS Support desktop icon (if the LMF is not running). See Figure 3-4 For the first connection the user may be prompted about FTP server localization on PC and choose the Ethernet adapter. A Choose Network Interface window will appear asking for IP Address of the Network Interface Card (NIC) of the element under test. See Figure 3-5. A Setting FTP Server root for Local Terminal window will appear to asking for the path to the root directory. For the typical LMF installation, the default Server Root path is C:\wlmf. See Figure 3-6. A Frame Selection window will appear asking for type of UBS under test. See Figure 3-7 A window similar to Figure 3-8 should appear. Click on BTS. A drop down menu appears. Select Enter invasive mode. See Figure 3-9 A message window appears stating that invasive mode is successful. See Figure 3-10. 68P09283A63-5 3-11 FOA AUG 2007 Using WinLMF Figure 3-5 Chapter 3: LMF Operation Network Interface Selection ti-cdma-01683.eps- 3-12 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-6 FTP Server ti-cdma-06188.eps- 68P09283A63-5 3-13 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-7 Frame Selection ti-cdma-01687.eps- 3-14 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Figure 3-8 Using WinLMF Local Terminal GUI ti-cdma-06194.eps- 68P09283A63-5 3-15 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-9 Invasive Mode Selection ti-cdma-06190.eps 3-16 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-10 Invasive Mode Message Window ti-cdma-06189.eps 68P09283A63-5 3-17 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation LMF Menus and Options The following figures display the menus and options available to the user. Figure 3-11 displays the selections available under the BTS menu. Figure 3-11 BTS Menu ti-cdma-01682.eps 3-18 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-12 displays the choices that can be selected for testing. Figure 3-12 Select Menu ti-cdma-06198.eps 68P09283A63-5 3-19 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-13 displays the actions for the DMI. Figure 3-13 Device Menu - DMI (HDModem) ti-cdma-01685.eps 3-20 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-14 displays the actions for the XMI. Figure 3-14 Device Menu - XMI ti-cdma-01686.eps 68P09283A63-5 3-21 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-15 displays the choices for the manually configuring equipment. Figure 3-15 Tools Menu - Options ti-cdma-06201.eps 3-22 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-16 displays the receive tests for the UBS. Figure 3-16 Tests Menu - RX ti-cdma-06199.eps 68P09283A63-5 3-23 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-17 displays the transmit tests for the UBS. Figure 3-17 Tests Menu - TX ti-cdma-06200.eps 3-24 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-18 through Figure 3-21display the various UTIL menu choices that allow analysis of the UBS under test. Figure 3-18 Util Menu - Power Meter ti-cdma-06204.eps 68P09283A63-5 3-25 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-19 Util Menu - Test Equipment ti-cdma-06205.eps 3-26 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Figure 3-20 Util Menu - Examine ti-cdma-06203.eps 68P09283A63-5 3-27 FOA AUG 2007 Using WinLMF Chapter 3: LMF Operation Figure 3-21 Util Menu - Edit ti-cdma-06202.eps Logging Out Logging out of a UBS can only be accomplished from the Graphical User Interface (GUI) mode. The GUI and CLI environments use the same connection to a UBS. If a GUI and the CLI session are running for the same UBS at the same time, logging out of the UBS environment will log out of it for both. 3-28 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Using WinLMF Logging Out of a UBS from the GUI Environment Follow the procedure in Procedure 3-4 to logout of a UBS when using the GUI environment. Procedure 3-4 UBS GUI Logout Procedure Click on File on the Local Terminal menu bar. Click the Exit item in the pull-down menu. UBS will perform a soft reset. Anytime the LMF is exited from the UBS, the DMI controller(s) will automatically reboot within 1 minute in order to clear out any test configurations and boot up under the original configuration in the NECB and NECJ files. On-Line Help Task oriented on-line help is available in the LMF by clicking on Help in the window menu bar, and selecting LMF Help from the pull–down menu. Figure 3-22 Help Screen ti-ccdm a-06191.eps 68P09283A63-5 3-29 FOA AUG 2007 Download Code to UBS Chapter 3: LMF Operation Download Code to UBS ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ The process of downloading code to a UBS consists of two principal steps: 1. Code transfer to the UBS followed by distribution to the devices 2. Code activation Normally, the OMC-R will download code to the UBS through the span line once the UBS is configured to establish communication with the OMC-R. However, there may be some occasions that the LMF may be used to download load instead, such as at a staging location used to pre-load replacement DMIs with same code load version required by OMC-R. Then, when the new DMI is taken to the site, it will integrate and synchronize much faster with the OMC-R. When the code is activated, the UBS will re–start, and the LMF will lose contact with the UBS. It will be necessary to log into the UBS again after the UBS devices complete initialization with the new code. Prerequisites The following must be accomplished before downloading code: • A bts–# folder has been created for the UBS in the cdma subdirectory of the LMF home directory. (Refer to WinLMF File Structure Overview on page 3-3) • The current NECB- —bts#.xml and NECJ- —bts#.xml files for the UBS are saved in the UBS bts–# folder • The LIF.xml file and code and data binary files for the software release are saved in the cdma\loads\ subdirectory folder of the LMF home directory, where is the number of the software release installed on the BSS. The should be the same as defined in the NECB/NECJ files • The LMF is logged into the UBS in invasive mode If WinZip is used to unzip codeload, please be sure to uncheck the CR/LF conversion on the WinZip tool: From WinZip window, select Options -> Configuration -> Miscellaneous and unchecked TAR file smart CR/LF conversion box. Download Procedure Code files are downloaded to the UBS using an FTP server. The user is given a choice of using the built–in LMF FTP server or an external FTP server. For initial download of a UBS, the built–in FTP server in the LMF should be used. This procedure covers using the LMF built–in FTP server. 3-30 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Download Code to UBS The UBS code load should always be synchronized with the download from the OMC-R before leaving the UBS site. Refer to Reset All Devices and Initialize Site Remotely on page 5-8 for the procedure to do this. Procedure 3-5 Download Code In the menu bar of the Local Terminal BTS window, select BTS > Download Code... If prompted that the “Following operation may overwrite NECB, NECJ, LIF, and calibration files on the BTS”, click Yes. In the dialog box which appears, if the Use Local FTP server checkbox is not checked, click in it to select this option. Result: A check mark will appear in the box. In field labeled Software version enter the as specified in the prerequisite section (for example, 2.19.0.0.20). If a “clean download” is required (download every file, even if they are the same as those currently installed on the UBS), click in the Perform clean load checkbox. Result: A check mark will appear in the box. Click Ok to start the download. Code download can require up to 40 minutes to complete. When the download is complete, click Ok to close the status report window. When the code load is complete, the UBS will re–start, and the LMF will lose contact with the UBS. Log the LMF into the UBS again. 68P09283A63-5 3-31 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Test Equipment Set Up ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Connecting Test Equipment to the UBS The following equipment is required to perform optimization: • LMF • Communications system analyzer model supported by the LMF • Non-radiating transmit line termination load • Directional coupler and in-line attenuator • RF cables and connectors • Null modem cable (see Figure 1-1) • GPIB interface box The following figures provide representative illustrations of connections for test equipment currently supported by the LMF: • Figure 3-23, Figure 3-24, Figure 3-25, and Figure 3-26 show the test set connections for TX calibration. • Figure 3-27, Figure 3-28, Figure 3-29, and Figure 3-30 show test set connections for optimization/ATP tests. • Figure 3-31, Figure 3-32, Figure 3-33, or Figure 3-34 illustrate cable calibration test set–up. Test Equipment GPIB Address Settings All test equipment except the Agilent E7495A and Anritsu MT8212B is controlled by the LMF through an IEEE-488/GPIB bus. To communicate on the bus, each piece of test equipment must have a GPIB address set which the LMF will recognize. The standard address settings used by the LMF for the various types of test equipment items are as follows: • Signal generator address: 1 • Power meter address: 13 • Communications system analyzer: 18 Using the procedures included in the Setting GPIB Addresses section of Appendix D Test Equipment Preparation, verify and, if necessary, change the GPIB address of each piece of test equipment used to match the above. 3-32 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Set Up Supported Test Equipment Optimization and ATP testing for CDMA2000 1X sites or carriers may be performed using the following test equipment: • Advantest R3267 Analyzer with Advantest R3562 Signal Generator • Agilent E4406A with E4432B Signal Generator • Agilent 8935 series E6380A communications test set (formerly HP 8935) with option 200 or R2K and with E4432B signal generator for 1X FER • Agilent E7495A or Agilent E7495B communications test sets The E4406A/E4432B pair, or the R3267/R3562 pair, should be connected together using a GPIB cable. In addition, the R3562 and R3267 should be connected with a serial cable from the Serial I/O to the Serial I/O. This test equipment is capable of performing tests in both IS-95 A/B mode and CDMA 2000 mode if the required options are installed. To prevent damage to the test equipment, all TX test connections must be through the directional coupler and in-line attenuator as shown in the test setup illustrations. Optional test equipment A spectrum analyzer, such as the HP8594E, and a signal generator supporting the required frequency ranges can be used to perform manual cable calibration. 68P09283A63-5 3-33 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Test Equipment Preparation See Appendix D Test Equipment Preparation for specific steps to prepare each type of test set and power meter to perform calibration and ATP. The Agilent E7495A communications test set requires additional setup and preparation. This is described in detail in Appendix D Test Equipment Preparation. Calibration of the communications test set (or equivalent test equipment) must be performed at the site before calibrating the overall test equipment set. Calibrate the communications test set after it has been allowed to warm up and stabilize for a minimum of 60 minutes. If any piece of the test equipment set (for example, test cable, RF adapter) has been replaced, the test equipment set must be re–calibrated. Failure to do so could introduce measurement errors, resulting in incorrect measurements and degradation to system performance. Equipment Warm-up Warm-up UBS equipment for a minimum of 60 minutes prior to performing the UBS optimization procedure. This assures UBS site stability and contributes to optimization accuracy. Time spent running initial power-up, hardware/firmware audit, and UBS download counts as warm-up time. Before connecting any test equipment directly to any UBS TX or duplexed TX/RX connector (for example, the TX/RX M connectors for a UBS equipped with IDRFs), verify there are NO channels keyed. At active sites, have the OMC–R place the carriers assigned to the XMI under test OOS. Failure to do so can result in serious personal injury and/or equipment damage. 3-34 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Set Up Automatic Cable Calibration Refer to Calibrate Test Cabling using Communications System Analyzer on page 3-64 for automatic cable calibration procedures using a communications test set. Manual Cable Calibration If manual cable calibration is required, refer to Calibrate Test Cabling Using Signal Generator & Spectrum Analyzer on page 3-69 for procedures to use a spectrum analyzer and signal generator. Set-up for TX Calibration Figure 3-23, Figure 3-24, Figure 3-25, and Figure 3-26 show test set connections for TX calibration. 68P09283A63-5 3-35 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Figure 3-23 TX Calibration Test Setup – Agilent 8935 TEST SETS TRANSMIT (TX) SET UP AGILENT 8935 SERIES E6380A (FORMERLY HP 8935) POWER SENSOR 100-W ATT (MIN) NON-RADIA TING RF LOAD HP-IB TO GPIB BOX POWER METER (OPTIONAL)* TX TEST CABLE OUT 50 Ω TERM. COMMUNICATIONS TEST SET TEST SET INPUT/ OUTPUT PORTS 30 DB DIRECTIONAL COUPLER CONTROL IEEE 488 GPIB BUS OR 10 DB MINIMUM IN-LINE ATTENUATOR RF IN/OUT TX TEST CABLE TX TEST IN CABLE * A POWER METER CAN BE USED IN PLACE OF THE COMMUNICATIONS TEST SET FOR TX CALIBRATION/AUDIT GPIB CABLE RX DIV TX/RX M (DUPLEXED TX AND RX) IDRF DIP SWITCH SETTINGS S MODE DATA FORMAT BAUD RATE UBS ON ADVANTEST MODEL R3465 FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT GPIB ADRS RS232-GPIB INTERFACE BOX RS232 NULL MODEM CABLE SSI CDMA LMF GPIB CONNECTS TO BACK OF UNIT INPUT 50-OHM G MODE UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL OR PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06170.eps 3-36 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Figure 3-24 Test Equipment Set Up TX Calibration Test Setup – Agilent E4406A and Advantest R3267 TEST SETS TRANSMIT (TX) SET UP AGILENT E4406A POWER SENSOR 100-W ATT (MIN) NON-RADIA TING RF LOAD POWER METER (OPTIONAL)* TX TEST CABLE OUT 30 DB DIRECTIONAL COUPLER 50 Ω TERM. COMMUNICATIONS TEST SET TEST SET INPUT/ OUTPUT PORTS CONTROL IEEE 488 GPIB BUS OR 1O DB MINIMUM IN-LINE ATTENUATOR RF INPUT 50 Ω TX TEST CABLE TX TEST CABLE IN * A POWER METER CAN BE USED IN PLACE OF THE COMMUNICATIONS TEST SET FOR TX CALIBRATION/AUDIT ADVANTEST MODEL R3267 GPIB CABLE RX DIV TX/RX M (DUPLEXED TX AND RX) IDRF DIP SWITCH SETTINGS RF IN S MODE DATA FORMAT BAUD RATE UBS ON FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT GPIB ADRS RS232-GPIB INTERFACE BOX G MODE RS232 NULL MODEM CABLE SSI CDMA LMF UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL OR PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06171.eps 68P09283A63-5 3-37 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Figure 3-25 TX Calibration Test Setup – Agilent E7495A TEST SETS TRANSMIT (TX) SET UP POWER SENSOR AGILENT E7495A TX TEST CABLE POWER METER PORT 1 RF OUT COMMUNICATIONS SYSTEM ANALYZER 100-W ATT (MIN.) NON-RADIA TING RF LOAD INTERNAL ETHERNET CARD PORT 2 RF IN OR TX TEST CABLE 30 DB DIRECTIONAL COUPLER 50 Ω TERM. 1O DB MINIMUM IN-LINE ATTENUATOR GPIO Port 2 RF In Ext Ref In Power REF 50 MHz Even Second Sync In Serial 1 Sensor Serial 2 Use only Agilent supplied power adapter TX TEST CABLE Port 1 RF Out / SWR GPS Antenna RX DIV TX/RX M (DUPLEXED TX AND RX) ETHERNET HUB IDRF PORT 2 RF IN SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OUT UBS NOTES: FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT 1. WHEN USING THE E7495A, TX TESTS REQUIRE A MINIMUM OF 30 DB ATTENUATION PLUS THE CABLE LOSSES. SSI 2. IF BTS IS EQUIPPED WITH DRDCS (DUPLEXED RX/TX SIGNALS), CONNECT THE TX TEST CABLE TO THE DRDC ANTENNA CONNECTOR. CDMA LMF UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL OR PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06172.eps 3-38 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Set Up Figure 3-26 TX Calibration Test Setup – Anritsu MT8212B TEST SETS TRANSMIT (TX) SET UP ANRITSU MT8212B RF OUT 50 Ω COMMUNICATIONS SYSTEM ANALYZER 100-W ATT (MIN.) NON-RADIA TING RF LOAD SERIAL INTERFACE CONNECTOR RF IN 50 Ω RF IN 50 Ω SERIAL INTERFACE TX AND RX TEST CABLE 30 DB DIRECTIONAL COUPLER 50 Ω TERM. 1O DB MINIMUM IN-LINE ATTENUATOR TX AND RX TEST CABLE RX DIV TX/RX M (DUPLEXED TX AND RX) RS232 SERIAL INTERFACE CABLE IDRF UBS FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT SSI CDMA LMF UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL OR PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) tti-cdma-06206.eps 68P09283A63-5 3-39 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Setup for ATP Figure 3-27, Figure 3-28, Figure 3-29, and Figure 3-30 show test set connections for ATP tests. 3-40 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Set Up Figure 3-27 ATP Test Setup – Agilent E4432B/8935 and Agilent E4432B/E4406A TEST SETS OPTIMIZATION/ATP SET UP AGILENT E4432B (TOP) AND 8935 SERIES E6380A (BOTTOM) RF OUTPUT 50 Ω TX/RX TEST CABLE RF OUTPUT 50 Ω SIGNAL GENERATOR 100-W ATT (MIN.) NON-RADIA TING RF LOAD RF IN/OUT OR RF INPUT 50 Ω DIRECTIONAL COUPLER (30 DB) RF IN/OUT GPIB COMMUNICATIONS SYSTEM ANALYZER EXT REF IN 50 Ω TERM. 10 MHZ IN PATTERN TRIG IN TRIGGER IN OR EVEN SEC SYNCH IN 10 MHZ REF OUT OR 10 MHZ OUT HP-IB OR GPIB TX/RX TEST CABLE TX TEST: 1O DB MINIMUM IN-LINE ATTENUATOR BNC “T” SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OU FREQ MONITOR 19.6608 MHZ CLOCK REFERENCE FROM SSI FREF OUT BNC “T” NOTES: OR 10 MHZ IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO 10 MHZ REF OUT ON SIDE OF CDMA BASE STATION TEST SET PATTERN TRIG IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO EVEN SECOND SYNC IN ON SIDE OF CDMA BASE STATION TEST SET. RX DIV AGILENT E4432B (TOP) AND E4406A (BOTTOM) TX/RX M (DUPLEXED TX AND RX) GPIB CABLE IDRF RF OUTPUT 50 Ω * BLACK RECTANGLES REPRESENT THE RAISED PART OF SWITCHES UBS DIP SWITCH SETTINGS * S MODE DATA FORMAT BAUD RATE RF INPUT 50 Ω TO TRIGGER IN ON REAR OF TRANSMITTER TESTER TO EXT REF IN ON REAR OF TRANSMITTER TESTER FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT SSI ON GPIB ADRS TO PATTERN TRIG IN ON REAR OF SIGNAL GENERATOR RS232 NULL MODEM CABLE BNC “T” NOTE: G MODE RS232-GPIB INTERFACE BOX CDMA LMF SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OUT FREQ MONITOR 19.6608 MHZ CLOCK REFERENCE FROM SSI FREF OUT 10 MHZ IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO 10 MHZ OUT (SWITCHED) ON REAR OF TRANSMITTER TESTER UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06174.eps 68P09283A63-5 3-41 FOA AUG 2007 Test Equipment Set Up Figure 3-28 Chapter 3: LMF Operation ATP Test Setup – Advantest R3267/3562 TEST SETS OPTIMIZATION/ATP SET UP RF OUT 50 Ω TX/RX TEST CABLE Advantest R3267 (Top) and R3562 (Bottom) SIGNAL GENERATOR MOD TIME BASE IN TO EXT TRIG ON REAR OF SPECTRUM ANALYZER 100-W ATT (MIN.) NON-RADIA TING RF LOAD SYNTHE REF IN EXT TRIG IN GPIB SPECTRUM ANALYZER INPUT 50 Ω INPUT 50 Ω 10 MHZ OUT EXT TRIG BNC “T” DIRECTIONAL COUPLER (30 DB) 50 Ω TERM. RF OUT 50 Ω GPIB TX/RX TEST CABLE TX TEST: 1O DB MINIMUM IN-LINE ATTENUATOR BNC “T” FREQ MONITOR 19.6608 MHZ CLOCK REFERENCE FROM SSI FREF OUT OR SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OUT NOTE: SYNTHE REF IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO 10 MHZ REF OUT ON REAR OF SPECTRUM ANALYZER RX DIV TX/RX M (DUPLEXED TX AND RX) GPIB CABLE IDRF * BLACK RECTANGLES REPRESENT THE RAISED PART OF SWITCHES UBS DIP SWITCH SETTINGS S MODE DATA FORMAT BAUD RATE ON FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT SSI GPIB ADRS G MODE RS232-GPIB INTERFACE BOX RS232 NULL MODEM CABLE CDMA LMF UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06173.eps 3-42 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Set Up Figure 3-29 ATP Test Setup – Agilent E7495A or E7495B ATP TEST SET UP TEST SET POWER METER AGILENT E7495A or E7495B (SEE NOTE FOR RX TEST ATTENUATION SELECTION) RX TEST PORT 1 RF OUT COMMUNICATIONS SYSTEM ANALYZER RF INPUT 50 Ω OR INPUT 50 Ω 100-W ATT (MIN.) NON-RADIA TING RF LOAD PORT 2 RF IN TX TEST 30 DB DIRECTIONAL COUPLER 50 Ω TERM. EVEN SECOND SYNC IN INTERNAL ETHERNET CARD NOTE: USE THE SAME CABLE SET FOR TX AND RX ATP. SWITCH THE CABLES DURING ALL ATP TESTS AS SHOWN. TX TEST: 1O DB MINIMUM IN-LINE ATTENUATOR GPIO Port 2 RF In Ext Ref In Power REF 50 MHz Even Second Sync In Serial 1 Sensor Serial 2 TEST CABLES Use only Agilent supplied power adapter TX/RX TEST Port 1 RF Out / SWR GPS Antenna RX DIV PORT 2 RF IN SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OUT TX/RX M (DUPLEXED TX AND RX) PORT 1 RF OUT NOTE: FOR RX TESTING, TOTAL RF PATH ATTENUATION (CABLES+COUPLERS+ATTENUATORS) MUST BE WITHIN THE FOLLOWING VALUES SPECIFIED FOR EACH TYPE OF TEST SET: ETHERNET HUB IDRF UBS E7495A: 25 TO 32 dB E7495B: 10 TO 100 dB FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT 2. WHEN USING THE E7495A, TX TESTS REQUIRE A MINIMUM OF 30 DB ATTENUATION PLUS THE CABLE LOSSES. SSI CDMA LMF 3. USE THE SAME CABLE SET FOR TX AND RX ATP. SWITCH THE CABLES DURING ALL ATP TESTS AS SHOWN. 4. IF BTS IS EQUIPPED WITH DUPLEXED RX/TX SIGNALS, CONNECT THE TX TEST CABLE TO THE DUPLEXED ANTENNA CONNECTOR. UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) 68P09283A63-5 INTERNAL PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06175.eps 3-43 FOA AUG 2007 Test Equipment Set Up Chapter 3: LMF Operation Figure 3-30 ATP Test Setup – Anritsu MT8212B TEST SET OPTIMIZATION/ATP SET UP ANRITSU MT8212B FREQ MONITOR 19.6608 MHZ CLOCK REFERENCE FROM SSI FREF OUT SYNC MONITOR EVEN SEC TICK PULSE REFERENCE FROM SSI TREF OUT RX TEST RF OUT 50 Ω COMMUNICATIONS SYSTEM ANALYZER 100-W ATT (MIN.) NON-RADIA TING RF LOAD RF IN 50 Ω SERIAL INTERFACE TX TEST SERIAL INTERFACE CONNECTOR RF IN 50 Ω RF OUT 50 Ω RX DIV TX/RX M (DUPLEXED TX AND RX) RS232 SERIAL INTERFACE CABLE IDRF UBS NOTES: 1. USE THE SAME CABLE SET FOR TX AND RX ATP. SWITCH THE CABLES DURING ATP TESTS AS SHOWN. 2. FOR RX TESTING (RSSI), TOTAL RF PATH ATTENUATION (CABLES+COUPLERS+ATTENUATORS) MUST BE 65 dB OR GREATER. FREF CRMS/LMT OUT CUSTOMER TREF ENET OUT SSI CDMA LMF UNSHIELDED TWISTED PAIR (UTP) CABLE (RJ45 CONNECTORS) INTERNAL OR PCMCIA ETHERNET NETWORK INTERFACE CARD (NIC) ti-cdma-06207.eps 3-44 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Connection to the LMF Test Equipment Connection to the LMF ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Test Equipment Connection The LMF computer platform provides two types of hardware interfaces which support three different test equipment communication methods. • The COM hardware interface (RS-232) supports connection with both of the following communication methods: General Purpose Interface Bus (GPIB) Direct serial connection • The Ethernet interface supports the network test equipment communication method. Additional information on each interface type is provided in the following subsections. COM Port Interface The LMF computer RS-232 serial bus interfaces are designated as COM connections or ports in software. These interfaces support communication with test equipment connected to the LMF computer either directly with a serial cable or through a GPIB interface device (GPIB box). The LMF normally uses COM1 for the interface. COM2 is not used unless the LMF computer has two RS-232 connectors. The COM port selected in the LMF can not be used for any other purpose when the LMF is using it. Selecting the COM port - Perform the following to select a COM port for use with test equipment needing either a GPIB or a direct serial connection: Procedure 3-6 Selecting a COM Port for GPIB or Serial Test Equipment Connection From the LMF window menu bar select Tools > Options. Result: The LMF Options window opens. If the Test Equipment tab is not in the forefront, click the tab to bring it forward. Click in the COM radio button in the GPIB/COM settings area. Result: A black dot appears in the circle. Select the COM port to use (normally COM1) from the dropdown in the Port: box of the GPIB/COM settings area. Click the Save button to save the selection configuration for future LMF sessions. Click the Close button to close the LMF Options window. 68P09283A63-5 3-45 FOA AUG 2007 Test Equipment Connection to the LMF Chapter 3: LMF Operation Disconnecting and Reconnecting the LMF and the COM port - The LMF can be disconnected from the active COM port by using the Disconnect Port button in the GPIB/COM settings area of the Test Equipment tab. Disconnecting the LMF may be needed, for example, to use a HyperTerminal connection for a hardware Man Machine Interface (MMI) communication session. Perform the following to disconnect or reconnect the LMF and the selected COM port. Procedure 3-7 Disconnect and Reconnect the LMF and the Active COM Port From the LMF window menu bar select Tools > Options. Result: The LMF Options window opens. If the Test Equipment tab is not in the forefront, click the tab to bring it forward. Disconnect the LMF from the active COM port: click the Disconnect Port button in the GPIB/COM settings area. Reconnect the LMF to the active COM port: click the Detect button in the GPIB Test equipment or Serial Test Equipment area. If no other operations are required in the LMF Options window click Close to close the window. Ethernet Interface The LMF computer Ethernet interface supports communication with test equipment which uses the network connection method. This interface uses Internet Protocol (IP) addressing to differentiate each node on the network. Motorola recommends that the Ethernet connection be done through an Ethernet hub. The hub connects to the LMF computer, the test equipment, and the base station Local Area Network (LAN). Connection details are as follows: Test equipment to hub – This is an Unshielded Twisted Pair (UTP) Ethernet cable with two 10/100Base–TX 8-contact modular connectors. LMF to hub – Use one of the following cable types to connect the LMF to the Hub: • Ethernet cable. Be sure the computer Network Interface Card (NIC) is set for either AUTO or to use the 8–contact modular connector only. • Coaxial cable between NIC and Hub. For a computer NIC equipped with a 10Base–2 (BNC) connector, use a BNC tee connector on the hub. If the hub does not have BNC connectors, use a BNC–to–UTP adapter with the tee connector. Connect a coaxial cable between the NIC and one end of the BNC tee crossbar. Hub to base station– Use one of the following, depending on the type of base station to be calibrated or tested: • For UBS with 10/100Base–T LAN: Connect an Ethernet cable between the hub and the SSI CRMS/LMT CUSTOMER ENET connector. 3-46 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Connection to the LMF Addressing Methods Different addressing methods are used for test equipment depending on the type of interface connection it has. The different addressing methods are described in the following subsections. GPIB Addresses GPIB addresses can range from 1 through 30. The LMF will accept any address in that range, but the numbers entered in the LMF Options window GPIB address box must match the addresses set in the test equipment. Motorola recommends using 1 for a CDMA signal generator, 13 for a power meter, and 18 for a communications system analyzer. To verify and, if necessary, change the GPIB addresses of the test equipment, refer to the Setting GPIB Addresses sections of Appendix D Test Equipment Preparation. Serial Connection This connection type uses a direct serial connection between the test equipment and the LMF computer platform. The Anritsu MT8212B communications test set is an example of test equipment using this type of connection. There are no specific addressing requirements for this type of interface. IP Addresses Test equipment using the Network connection type use IP addresses to identify them on the Ethernet LAN. The E7495A and E7495B communications test sets are examples of Network connection test equipment. Setting the IP address in the test equipment is covered in the specific test equipment (for example, Agilent E7495) set-up section of Appendix D Test Equipment Preparation. 68P09283A63-5 3-47 FOA AUG 2007 Test Equipment Selection Chapter 3: LMF Operation Test Equipment Selection ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Test Equipment Selection Test equipment selection is performed in the LMF Options window, accessed through Tools > Options in the LMF window menu bar. The window has four tabs covering different categories of options. Test equipment operations, including selection, are performed on the Test Equipment tab. For software release 2.20.0.x (R20), the test equipment list displayed on this tab is context sensitive based on the Connection type selected. • When GPIB is selected, only test equipment with a GPIB interface is displayed. • When Serial is selected, only test equipment needing a direct serial connection is displayed. • When Network is selected, only test equipment needing an Ethernet connection is displayed. Manual and Autodetect Selection Test equipment can be manually specified before or after the test equipment is connected. The LMF does not try to determine if the test equipment is actually connected for manual selection. The LMF can be commanded to automatically detect test equipment connected to it. This autodetection feature is operated by a Detect button located in the test equipment list area for each connection type (GPIB, Serial, or Network). Selecting Test Equipment There is a different set of test equipment selection procedures for each test equipment connection type. These are: • GPIB connection • Serial connection • Network (Ethernet) connection Selection Procedures Test equipment selection procedures are contained in the following subsections. Each subsection is for a different connection type. Each subsection includes a procedure for manually specifying test equipment items and a procedure to have the LMF automatically detect the connected test equipment. 3-48 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Selection GPIB Interface Test Equipment Manual Selection and Autodetection Prerequisites - The following must be done before performing these procedures: • LMF computer and test equipment are both correctly connected to the GPIB box • Test equipment is turned on • GPIB addresses set in the test equipment have been verified as correct using the applicable procedures in Appendix D Test Equipment Preparation. Manual selection – Test equipment may be selected manually even if it is not connected to the LMF. Procedure 3-8 Manually Selecting Test Equipment - GPIB Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the GPIB radio button in the Connection Type area. Result: A black dot appears in the circle. Click the COM radio button in the GPIB/COM settings area. Result: A black dot appears in the circle. Select the correct LMF computer serial port from the Port: pick list (normally COM1) (Refer to the Test Equipment Connection to the LMF on page 3-45 section of this chapter). In the GPIB Test equipment area click the checkbox(es) of the test equipment being used. Result: Checkmarks appear in the boxes clicked on. If one is not already displayed, type the GPIB address for each checked piece of test equipment in the corresponding box labeled GPIB. Recommended Addresses 1 = CDMA Signal generator 13 = Power Meter 18 = CDMA Analyzer When the test equipment items are manually selected, the CDMA analyzer is used only if a power meter is not selected. Continued 68P09283A63-5 3-49 FOA AUG 2007 Test Equipment Selection Chapter 3: LMF Operation Procedure 3-8 Manually Selecting Test Equipment - GPIB Interface (Continued) Click the Apply button. The button will darken until the selection is committed. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup.A checkmark appears in the box. 10 Click the Save button to save the selection configuration for future LMF sessions. 11 Click the Close button to close the LMF Options window. When two devices of the same type have been selected, a window will appear warning that more than one signal generator/power meter/ analyzer has been chosen. Click the Continue button to close this window. The checkbox can be clicked to prevent the window from being displayed again, if desired. Automatically Selecting Test Equipment (Autodetection) – When using the autodetection feature to select test equipment, the LMF determines which test equipment items are actually communicating with the LMF. Procedure 3-9 Autodetecting Test Equipment - GPIB Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the GPIB radio button in the Connection Type area. Result: A black dot appears in the circle. Click the COM radio button in the GPIB/COM settings area. Result: A black dot appears in the circle. Select the correct LMF computer serial port from the Port: pick list (normally COM1) (Refer to the Test Equipment Connection to the LMF on page 3-45 section of this chapter). Continued 3-50 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Procedure 3-9 Test Equipment Selection Autodetecting Test Equipment - GPIB Interface (Continued) If they are not already displayed, enter the GPIB address for each piece of required test equipment, separated by commas, in the GPIB Addresses: box in the GPIB Test equipment area. Recommended Addresses 1 = CDMA Signal generator 13 = Power Meter 18 = CDMA Analyzer In autodetection when both a power meter and a CDMA analyzer are selected, the LMF uses the first item that is capable of performing RF power measurement listed in the GPIB Addresses: box. The address for a CDMA signal generator is normally 1, the address for a power meter is normally 13, and the address for a CDMA analyzer is normally 18. If 1,13,18 is listed in the GPIB Addresses: box, the power meter (13) is used for RF power measurements. When the test equipment items are manually selected, the CDMA analyzer is used only if a power meter is not selected. Click the Detect button. The button will darken until the selection is committed. Result: For each detected equipment item, a check will appear in its checkbox and its GPIB address will appear in its GPIB box. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup. Result: A checkmark appears in the box. Click the Save button to save the selection configuration for future LMF sessions. 10 Click the Close button to close the LMF Options window. When two devices of the same type have been selected, a window will appear warning that more than one signal generator/power meter/ analyzer has been chosen. Click the Continue button to close this window. The checkbox can be clicked to prevent the window from being displayed again, if desired. Serial Interface Test Equipment Manual Selection and Autodetection Prerequisites – The following must be done before performing these procedures: • Test equipment is correctly connected to the LMF computer RS-232 connector with a serial cable • Test equipment is turned on 68P09283A63-5 3-51 FOA AUG 2007 Test Equipment Selection Chapter 3: LMF Operation Manual selection – Test equipment may be selected manually even if it is not connected to the LMF. Procedure 3-10 Manually Selecting Test Equipment - Serial Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the Serial radio button in the Connection Type area. Result: A black dot appears in the circle. Click the COM radio button in the GPIB/COM settings area. Result: A black dot appears in the circle. Select the correct LMF computer serial port from the Port: pick list (normally COM1) (Refer to the Test Equipment Connection to the LMF on page 3-45 section of this chapter). In the Serial Test equipment, area click the checkbox(es) of the test equipment being used. Result: Checkmarks appear in the box(es) clicked on. Click the Apply button. The button will darken until the selection is committed. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup. Result: A checkmark appears in the box. Click the Save button to save the selection configuration for future LMF sessions. 10 Click the Close button to close the LMF Options window. Automatically Selecting Test Equipment (Autodetection) – When using the autodetection feature to select test equipment, the LMF determines which test equipment items are actually communicating with the LMF. Procedure 3-11 Autodetecting Test Equipment - Serial Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the Serial radio button in the Connection Type area. Result: A black dot appears in the circle. Continued 3-52 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Equipment Selection Procedure 3-11 Autodetecting Test Equipment - Serial Interface (Continued) Click the COM radio button in the GPIB/COM settings area. Result: A black dot appears in the circle. Select the correct LMF computer serial port from the Port: pick list (normally COM1) (Refer to the Test Equipment Connection to the LMF on page 3-45 section of this chapter). Choose the test equipment on the Serial Test Equipment list by clicking the corresponding checkbox. Result: A checkmark appears in the box. Click the Detect button. The button will darken until the selection is committed. Result: For each detected equipment item, a check will appear in its checkbox. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup. Result: A checkmark appears in the box. Click the Save button to save the selection configuration for future LMF sessions. 10 Click the Close button to close the LMF Options window. Network Interface Test Equipment Manual Selection and Autodetection Prerequisites– The following must be done before performing these procedures: • Be sure that no other equipment is connected to the LMF. • Test equipment is correctly connected to the LMF computer through the Ethernet LAN • The IP address is set in the test equipment as specified in the test equipment model (for example, Agilent E7495) set-up section of Appendix D Test Equipment Preparation. • Test equipment is turned on Manual selection – Test equipment may be selected manually even if it is not connected to the LMF. Procedure 3-12 Manually Selecting Test Equipment - Network Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the Network radio button in the Connection Type area. Result: A black dot appears in the circle. Continued 68P09283A63-5 3-53 FOA AUG 2007 Test Equipment Selection Chapter 3: LMF Operation Procedure 3-12 Manually Selecting Test Equipment - Network Interface (Continued) In the Ethernet Test equipment area click the checkbox(es) of the test equipment being used. Result: Checkmarks appear in the box(es) clicked on. If it is not already displayed, enter the IP address for the required piece test equipment in the IP box in the Ethernet Test equipment area. Click the Apply button. The button will darken until the selection is committed. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup. Result: A checkmark appears in the box. Click the Save button to save the selection configuration for future LMF sessions. Click the Close button to close the LMF Options window. Automatically Selecting Test Equipment (Autodetection) – When using the autodetection feature to select test equipment, the LMF determines which test equipment items are actually communicating with the LMF. Procedure 3-13 Autodetecting Test Equipment - Network Interface In the LMF menu bar, select Tools > Options. Result: The LMF Options window appears. Click on the Test Equipment tab (if not in the forefront). Click the Network radio button in the Connection Type area. Result: A black dot appears in the circle. If it is not already displayed, enter the IP address for the required piece test equipment in the IP box in the Ethernet Test equipment area. Click the Detect button. The button will darken until the selection is committed. Result: For each detected equipment item, a check will appear in its checkbox. Click the Detect on startup checkbox in the Autodetection settings area to allow the LMF to detect the test equipment automatically on application startup. Result: A checkmark appears in the box. Click the Save button to save the selection configuration for future LMF sessions. Click the Close button to close the LMF Options window. 3-54 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Set Calibration Test Set Calibration ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Test Set Calibration Background Proper test equipment calibration ensures that the test equipment and associated test cables do not introduce measurement errors, and that measurements are correct. If the test equipment set being used to interface with the base station has been calibrated and maintained as a set, this procedure does not need to be performed. (Test equipment set includes LMF computer, communications test set, additional test equipment, associated test cables, and adapters.) This procedure must be performed before beginning the optimization. Verify all test equipment (including all associated test cables and adapters actually used to interface all test equipment and the base station) has been calibrated and maintained as a set. If any piece of test equipment, test cable, or RF adapter, that makes up the calibrated test equipment set, has been replaced, re-calibration must be performed. Failure to do so can introduce measurement errors, resulting in incorrect measurements and degradation to system performance. Calibration of the communications test set (or equivalent test equipment) must be performed at the site before calibrating the overall test set. Calibrate the test equipment after it has been allowed to warm-up and stabilize for a minimum of 60 minutes. 68P09283A63-5 3-55 FOA AUG 2007 Test Set Calibration Chapter 3: LMF Operation Calibration Procedures Included Automatic Procedures included in this section use the LMF automated calibration routines to determine path losses of the supported communications analyzer, power meter, associated test cables, adapters, and (if used) antenna switch that make up the overall calibrated test equipment set. After calibration, the gain/loss offset values are stored in a test measurement offset file on the LMF computer. Manual Agilent E4406A Transmitter Tester - The E4406A does not support the power level zeroing calibration performed by the LMF. If this instrument is to be used for Bay Level Offset calibration and calibration is attempted with the LMF Calibrate Test Equipment function, the LMF will return a status window failure message stating that zeroing power is not supported by the E4406A. Refer to Appendix D Test Equipment Preparation for instructions on using the instrument’s self-alignment (calibration) function prior to performing Bay Level Offset calibration. Power Meters - Manual power meter calibration procedures to be performed prior to automated calibration are included in Appendix D Test Equipment Preparation. Cable Calibration - Manual cable calibration procedures using the Advantest R3465 communications system analyzer are provided in Appendix D Test Equipment Preparation, if needed. Prerequisites Ensure the following prerequisites have been met before proceeding: • Test equipment is correctly connected and turned on. • Test equipment addressing is set as required for the connection type being used (GPIB, Serial, Network) Calibrate Test Equipment Function (Except Agilent E4406A and Anritsu MT8212B) The Calibrate Test Equipment function zeros the power measurement level of the test equipment item to be used for TX calibration and audit. If both a power meter and an analyzer are connected, only the power meter is zeroed. 3-56 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Set Calibration 1. The Agilent E4406A transmitter tester does not support power measurement level zeroing. Refer to the Test Equipment Calibration section of Appendix F for E4406A calibration. 2. Power measurement zeroing and other required calibration procedures for the Anritsu MT8212B are included in the Calibrating the Anritsu MT8212B on page 3-57 subsection below. Prerequisites • Test equipment to be zeroed has been connected correctly for tests to be run. • Test equipment has been selected in the LMF (Test Equipment Selection on page 3-48) and detected. Procedure Perform the following to calibrate the test equipment. Procedure 3-14 Calibrate Test Equipment - Power Measurement Zeroing From the Util menu, select Calibrate Test Equipment from the pull-down menu. A Directions window is displayed. Follow the directions provided. Click on Continue to close the Directions window and start the calibration process. A status report window is displayed. Click on OK to close the status report window. Calibrating the Anritsu MT8212B Three types of calibration are required for the MT812B. These are: • Zero out power meter • Calibrate TX Analyzer • Calibrate CW Generator Procedures for each type of calibration is covered in the following subsections. 68P09283A63-5 3-57 FOA AUG 2007 Test Set Calibration Chapter 3: LMF Operation Zero Out Power Meter Before using the MT8212B test set to perform RF power measurement, the test set internal power meter function must be zeroed. Prerequisites – The following must be done before the zeroing out the power meter: • The test set is connected to the LMF computer serial port with the Anritsu 800-441 RS-232 serial interface cable • Test equipment is turned on and has warmed up for at least 60 minutes. • Test equipment has been selected/detected in the LMF (Test Equipment Selection on page 3-48) Zero out power meter – Perform the following to zero out the power meter function before performing RF power measurements. Procedure 3-15 Anritsu MT8212B Multi-function Test Set Zero Out Power Meter In the LMF menu bar select Util > Calibrate Test Equipment. Result: ACalibrate Anritsu MT8212B window appears. Click in the Option for zero out power meter on Anritsu MT8212B radio button in the Zero Out Power Meter area. Result: A black dot appears in the circle. Click on OK. Result: A Directions window is displayed. Follow the directions provided. Result: A status report window will open. Click on OK to close the status report window. Calibrate TX Analyzer TX Analyzer calibration should be accomplished before performing any ATP operations with the MT8212B. Prerequisites – The following must be done before the CW generator calibration: • The test set is connected to the LMF computer serial port with the Anritsu 800-441 RS-232 serial interface cable • Test equipment has been selected/detected in the LMF (Test Equipment Selection on page 3-48) • Additional items must be available for the TX Analyzer calibration method chosen as indicated in the following: 3-58 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP • Test Set Calibration Standard Open-Short-Load Components calibration: Anritsu 22N50 Open/Short, DC to 18 GHz, N(m) connector, 50 ohm Anritsu SM/PL precision load, DC-to-4 GHz, 42 dB, N(m) connector, 50 ohm • Standard InstaCal™ calibration: Anritsu ICN50 InstaCal calibration module, 2 MHz to 4 GHz, N(m) connector, 50 ohm TX analyzer calibration – Perform the following to calibrate the MT8212B TX analyzer function.. Procedure 3-16 Anritsu MT8212B Multi-function Test Set TX Analyzer Calibration In the LMF menu bar select Util > Calibrate Test Equipment.Calibrate Anritsu MT8212B window appears Click in the radio button in the Calibrate TX Analyzer area. Result: A black dot appears in the circle. Select the required frequency band from the dropdown list in the Frequency Band: box. The dropdown list in the Frequency Band: box is automatically populated with selections for the base station the LMF is logged into. Enter the channel number to be calibrated in the Channel box. Select the desired calibration method from the dropdown list in the Calibration Method box. Click OK. Result: A Directions window is displayed. Follow the directions provided. When actions required by directions have been completed, click on Continue to close the Directions window and start the generator calibration process. Result: A status report window is displayed. Click on OK to close the status report window. Calibrate CW Generator Before using the MT8212B test set to perform base station RSSI testing, the test set internal Continuous Wave (CW) generator must be calibrated. 68P09283A63-5 3-59 FOA AUG 2007 Test Set Calibration Chapter 3: LMF Operation Prerequisites - The following must be done before the CW generator calibration: • The test set is connected to the LMF computer serial port with the Anritsu 800-441 RS-232 serial interface cable • Test equipment is turned on and has warmed up for at least 60 minutes. • Test equipment has been selected/detected in the LMF (Test Equipment Selection on page 3-48) • RX cable(s) used in the calibration process must be calibrated for the channel for which the CW generator is to be calibrated (refer to Figure 3-34 and Calibrating cables on page 3-65) CW generator calibration - Perform the following to calibrate the MT8212B internal CW generator before performing RSSI testing with this test set. Procedure 3-17 Anritsu MT8212B Multi-function Test Set CW Generator Calibration In the LMF menu bar select Util > Calibrate Test Equipment. Result: Calibrate Anritsu MT8212B window appears Click in the radio button in the Calibrate CW Generator area. Result: A black dot appears in the circle. Select the required frequency band from the dropdown list in the Frequency Band: box. The dropdown list in the Frequency Band: box is automatically populated with selections for the base station the LMF is logged into. Enter the channel or channels to be calibrated in the Channel(s) box (separate multiple channels with a comma and no space). When two or more channels numbers are entered, the generator will be calibrated for each channel. Interpolation will be accomplished for other channels as required for TX calibration. Channels must be within the range of the selected frequency band. Click OK. Result: A Directions window is displayed. Follow the directions provided. When actions required by directions have been completed, click on Continue to close the Directions window and start the generator calibration process. Result: A status report window is displayed. 3-60 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Test Set Calibration Procedure 3-17 Anritsu MT8212B Multi-function Test Set CW Generator Calibration (Continued) Click on OK to close the status report window. 68P09283A63-5 3-61 FOA AUG 2007 Setting and Editing Generator Calibration Data Chapter 3: LMF Operation Setting and Editing Generator Calibration Data ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Generator Calibration Data Generator calibration data is automatically stored in a generator calibration data file by the LMF when the generator function of a test equipment item is calibrated using the LMF Util > Calibrate Test Equipment functions. Stored data values can be edited with this procedure, or new data can be entered manually for a test equipment item generator function which was calibrated without using the LMF. This procedure MUST be used to enter calibration data values for any MT8212B which was calibrated without using the LMF. Failure to do this will generate incorrect results for any RSSI testing performed. Prerequisites The LMF is logged into a BTS. Set or Edit Generator Calibration Data Perform the following to enter new calibration data or edit existing data. Procedure 3-18 Set or Edit Generator Calibration Data In the LMF menu bar select Util > Edit > Generator Calibration Data. Result: Generator Calibration Data window appears with tabs for each type of generator test equipment calibrated using the LMF (for example, the Anritsu MT8212B). Click on the tab for the generator with data to be edited or entered. Result: The tab moves to the forefront. To edit existing values, click in the data field to be edited and make required changes. To add a new channel and its data: 1. Click the Add Row button. 2. Click in the field where data is to be entered; for example, Frequency Band, Channel #, or Power (dB). 3. Enter the desired value. Continued 3-62 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Setting and Editing Generator Calibration Data Procedure 3-18 Set or Edit Generator Calibration Data (Continued) For Frequency Band fields, select the required frequency band from the dropdown provided. Selections are made available for the BTS which the LMF is logged into. To delete a row, click in the row, and then click the Delete Row button. For each tab with changes, click the Save button to save the displayed values. • Values entered after the Save button was used will not be saved. • If generator calibration values exist for two different channels assigned to one frequency band, the LMF will interpolate for all other channels on this frequency band. • Entered values will be used by the LMF as soon as they are saved. It is not necessary to log out and log back into the LMF for changes to take effect. 68P09283A63-5 3-63 FOA AUG 2007 Cable Calibration Chapter 3: LMF Operation Cable Calibration ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Calibrating Cables Overview The cable calibration function measures the loss (in dB) for the TX and RX cables that are to be used for testing. A CDMA analyzer is used to measure the loss of each cable configuration (TX cable configuration and RX cable configuration). The cable calibration consists of the following: • Measuring the loss of a short cable – This is required to compensate for any measurement error of the analyzer. The short cable (used only for the calibration process) is used in series with both the TX and RX cable configuration when measuring. The measured loss of the short cable is deducted from the measured loss of the TX and RX cable configuration to determine the actual loss of the TX and RX cable configurations. The result is then adjusted out of both the TX and RX measurements to compensate for the measured loss. • Measuring the short cable plus the RX cable configuration loss – The RX cable configuration normally consists only of a coax cable with type-N connectors that is long enough to reach from the BTS RX port of the test equipment. Refer to Figure 3-31, Figure 3-32, Figure 3-33, or Figure 3-34 for specific cable and connection requirements for each type of communications system analyzer. • Measuring the short cable plus the TX cable configuration loss – The TX cable configuration normally consists of two coax cables with type N connectors and a directional coupler, a load, and an additional attenuator (if required by the specified BTS). The total loss of the path loss of the TX cable configuration must be as required for the BTS (normally 30 or 50 dB). Refer to Figure 3-31, Figure 3-32, Figure 3-33, or Figure 3-34 for specific cable and connection requirements for each type of communications system analyzer. Cable Calibration Set–up Diagrams Figure 3-31 and Figure 3-32 show the cable calibration set–up for various supported test sets. The left side of the diagram depicts the location of the input and output connectors of each test equipment item, and the right side details the set up for each test. Calibrate Test Cabling using Communications System Analyzer Cable Calibration is used to calibrate both TX and RX test cables. 3-64 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Cable Calibration Prerequisites Ensure the following prerequisites have been met before proceeding: • One of the following: LMF computer serial port and test equipment are connected to the GPIB box For MT8212B, the test equipment is connected to the LMF computer serial port For E7495A/B, the LMF computer NIC and the E7495 are connected to the Ethernet hub (Test Equipment Connection section) • Test equipment is turned on and has warmed up for at least 60 minutes. • Test equipment has been selected/detected in the LMF (Refer to the Selection Procedures subsection of the Test Equipment Selection section) Calibrating cables Refer to Figure 3-31, Figure 3-32, Figure 3-33, or Figure 3-34 and perform the following to calibrate the test cable configurations. Procedure 3-19 Automatic Cable Calibration From the Util menu, select Cable Calibration. Result: A Cable Calibration window is displayed. Enter the channel number(s) in the Channels box. Multiple channel numbers must be separated with a comma and no space (for example; 200,800). When two or more channel numbers are entered, the cables are calibrated for each channel. Interpolation is accomplished for other channels as required for TX calibration. In the Cable Calibration pick list select one of the following: • TX and RX Cable Cal • TX Cable Cal • RX Cable Cal Click OK and follow the direction displayed for each step. A status report window displays the results of the cable calibration. 68P09283A63-5 3-65 FOA AUG 2007 Cable Calibration Chapter 3: LMF Operation Figure 3-31 Cable Calibration Test Setup – Agilent 8935 CALIBRATION SET UP SUPPORTED TEST SETS A. SHORT CABLE CAL HEWLETT-P ACKARD MODEL HP 8935 SHORT CABLE ANT IN DUPLEX OUT TEST SET B. RX TEST SETUP N-N FEMALE ADAPTER RX CABLE SHORT CABLE TEST SET C. TX TEST SETUP 50 Ω TERM. 100-W ATT (MIN) NON-RADIA TING RF LOAD DIRECTIONAL COUPLER (30 DB) 10 DB MINIMUM IN-LINE ATTENUATOR SHORT CABLE TX CABLE N-N FEMALE ADAPTER RX CABLE TX CABLE FOR DRDC TX TEST CABLE CALIBRATION TEST SET ti-cdma-06176.eps 3-66 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Cable Calibration Figure 3-32 Cable Calibration Test Setup – Advantest R3267/R3562,E4406A/E4432B, and Agilent E4432/8935 Series E6380A SUPPORTED TEST SETS CALIBRATION SET UP ADVANTEST R3267 (TOP) AND R3562 (BOTTOM) A. SHORT CABLE CAL SHORT CABLE TEST SET RF IN B. RX TEST SETUP EXT TRIG IN MOD TIME BASE IN (EXT REF IN) RF OUT N-N FEMALE ADAPTER NOTE: SYNTHE REF IN on rear signal generator is connected to 10 MHZ OUT on rear of spectrum analyzer RX CABLE AGILENT E4432B (TOP) AND E4406A (BOTTOM) SHORT CABLE TEST SET RF OUTPUT 50 OHM RF INPUT 50 OHM C. TX TEST SETUP 50 Ω TERM. AGILENT E4432B (TOP) AND 8935 SERIES E6380A (BOTTOM) RF OUTPUT 50 Ω 100-W ATT (MIN) NON-RADIA TING RF LOAD DIRECTIONAL COUPLER (30 DB) 10 DB MINIMUM IN-LINE ATTENUATOR SHORT CABLE TX CABLE N-N FEMALE ADAPTER RX CABLE ANT IN NOTE: 10 MHZ IN on rear of signal generator is connected to 10 MHZ REF OUT on side of CDMA Base Station Test Set TX CABLE FOR DUPLEXED TX/RX TEST CABLE CALIBRATION TEST SET ti-cdma-06177.eps 68P09283A63-5 3-67 FOA AUG 2007 Cable Calibration Chapter 3: LMF Operation Figure 3-33 Cable Calibration Test Setup – Agilent E7495A and E7495B CALIBRATION SET UP SUPPORTED TEST SETS A. SHORT CABLE CAL AGILENT E7495A OR E7495B 10 DB PAD SHORT CABLE TEST SET 10 DB PAD B. RX and TX TEST SETUP 50 Ω TERM. 10 DB MIMIMUM IN-LINE ATTENUATOR 100-W ATT (MIN) NON-RADIA TING RF LOAD GPIO Power REF 50 MHz Ext Ref In DIRECTIONAL COUPLER (30 DB) TX CABLE Use only Agilent supplied power adapter 10 DB PAD Even Second Sync In Serial 1 Port 2 RF In Sensor Serial 2 Port 1 RF Out / SWR GPS Antenna PORT 2 RF IN SHORT CABLE RX CABLE PORT 1 RF OUT N-N FEMALE ADAPTER 10 DB PAD TEST SET TX CABLE FOR DUPLEXED TX/RX TEST CABLE CALIBRATION NOTES: 1. FOR RX TESTING, TOTAL RF PATH ATTENUATION (CABLES+COUPLERS+ATTENUATORS) MUST BE WITHIN THE VALUES SPECIFIED BELOW FOR EACH TYPE OF TEST SET: E7495A: 25 TO 32 dB E7495B: 10 TO 100 dB 2. WHEN USING THE E7495A, TX TESTS REQUIRE A MINIMUM OF 30 DB ATTENUATION PLUS THE CABLE LOSSES. ti-cdma-06178.eps 3-68 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Cable Calibration Figure 3-34 Cable Calibration Test Setup – Anritsu MT8212B SUPPORTED TEST SETS CALIBRATION SET UP A. SHORT CABLE CAL ANRITSU MT8212B SHORT CABLE RF IN 50 Ω TEST SET RF OUT 50 Ω C. RX and TX TEST SETUP 50 Ω TERM. 100-W ATT (MIN.) NON-RADIA TING RF LOAD DIRECTIONAL COUPLER (30 DB) TX TESTS: 10 DB MINIMUM IN-LINE ATTENUATOR RX TEST: 35 DB MINIMUM IN-LINE ATTENUATOR TX AND RX CABLE SHORT CABLE NOTE: FOR RX TESTING (RSSI), TOTAL RF PATH ATTENUATION (CABLES+COUPLERS+ATTENUATORS) MUST BE 65 dB OR GREATER. TX AND RX CABLE N-N FEMALE ADAPTER TEST SET ti-cdma-06208.eps Calibrate Test Cabling Using Signal Generator & Spectrum Analyzer Manual cable calibration can be performed by following Procedure 3-20 to calibrate the TX/duplexed RX cables using a signal generator and spectrum analyzer. Refer to Figure 3-35, if required. Follow Procedure 3-21 to calibrate the non–duplexed RX cables using the signal generator and spectrum analyzer. Refer to Figure 3-36, if required. 68P09283A63-5 3-69 FOA AUG 2007 Cable Calibration Chapter 3: LMF Operation TX and Duplexed RX Cable Calibration Procedure 3-20 Calibrating TX and Duplexed RX Cables Using Signal Generator and Spectrum Analyzer Connect a short test cable between the spectrum analyzer and the signal generator. Set signal generator to 0 dBm at the customer frequency. Use a spectrum analyzer to measure signal generator output (see Figure 3-35 A) and record the value. Connect the spectrum analyzer’s short cable to Figure 3-35 point B, (as shown in the lower right portion of the diagram) to measure cable output at customer frequency. Record the value at point B, Calibration factor = A - B. Example: Cal = -1 dBm - (-53.5 dBm) = 52.5 dB The short cable is used for calibration only. It is part of the final test setup. After calibration is completed, rearrange any cables. Use the equipment setup, as is, to ensure test procedures use the correct calibration factor. Figure 3-35 TX and Duplexed RX Cable Calibration SIGNAL GENERATOR SPECTRUM ANALYZER SHORT TEST CABLE 40W NON-RADIATING RF LOAD 50 OHM TERMINATION SPECTRUM ANALYZER 10DB MINIMUM, 20 W IN-LINE ATTENUATOR SHORT TEST CABLE THIS WILL BE THE TX TEST CABLE CONNECTION TO THE POWER SENSOR OR COMMUNICATIONS TEST SET INPUT IPORT DURING TX CALIBRATION AND ATP TESTS. SIGNAL GENERATOR 30 DB DIRECTIONAL COUPLER CABLE FROM 10 DB MINIMUM @ 20W ATTENUATOR TO THE POWER SENSOR OR COMMUNICATION TEST SET. ti-cdma-00145.eps 3-70 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Cable Calibration Non–duplexed RX Cable Calibration Procedure 3-21 Calibrating RX Cables Using a Signal Generator and Spectrum Analyzer Connect a short test cable to the spectrum analyzer and connect the other end to the Signal Generator. Set signal generator to -10 dBm at the customer’s RX frequency. Use spectrum analyzer to measure signal generator output (see Figure 3-36, A) and record the value for A. Connect the test setup, as shown in the lower portion of the diagram to measure the output at the customer’s RX frequency. Record the value atFigure 3-36, point B. Calibration factor = A - B. Example: Cal = -12 dBm - (-14 dBm) = 2 dBm The short cable is used for calibration only. It is not part of the final test setup. After calibration is completed, do not rearrange any cables. Use the equipment setup as is to ensure test procedures use the correct calibration factor. 68P09283A63-5 3-71 FOA AUG 2007 Cable Calibration Chapter 3: LMF Operation Figure 3-36 Non-Duplex RX Cable Calibration SIGNAL GENERATOR SIGNAL GENERATOR SPECTRUM ANALYZER SHORT TEST CABLE CONNECTION TO THE COMMUNICATION TEST SET OUTPUT PORT DURING RX MEASUREMENTS. SPECTRUM ANALYZER SHORT TEST CABLE BULLET CONNECTOR LONG CABLE 2 CONNECTION TO THE RX PORTS DURING RX MEASUREMENTS. ti-cdma-06209.eps Setting Cable Loss Values Cable loss values for the TX and RX test cable configurations are normally set by accomplishing cable calibration using the applicable test equipment. The resulting values are stored in the cable loss files. The cable loss values can also be set/changed manually. If cable calibration was performed without using the LMF, cable loss values must be manually entered in the LMF database. Failure to do this will result in inaccurate UBS calibration and reduced site performance. Prerequisites LMF is logged into the UBS 3-72 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Cable Calibration Procedure Perform the following to set cable loss values. Procedure 3-22 Setting Cable Loss Values In the LMF menu bar, click on Util > Edit > Cable Loss In the data entry pop–up window, select one of the following: • TX Cable Loss • RX Cable Loss To add a new channel number, click on Add Row, and click in Channel# and Loss (dBm) columns and enter the desired values. To edit existing values, click in the data box to be changed and change the value. To delete a row, click on the row and then click on the Delete Row button. To save displayed values, click on the Save button. To exit the window, click on the Dismiss button. Values entered/changed after the Save button was used are not saved. • If cable loss values exist for two different channels, the LMF will interpolate for all other channels. • Entered values are used by the LMF as soon as they are saved. Logging out and logging in again is not necessary. 68P09283A63-5 AUG 2007 3-73 FOA Cable Calibration Chapter 3: LMF Operation 3-74 68P09283A63-5 FOA AUG 2007 Chapter Acceptance Test Procedures ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 68P09283A63-5 AUG 2007 4-1 FOA Introduction to ATP Chapter 4: Acceptance Test Procedures Introduction to ATP ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Introduction General The Acceptance Test Procedures (ATP) allow Cellular Field Engineers (CFEs) to run automated acceptance tests on all UBS subsystem devices equipped in the NEC using the LMF and the test equipment it supports. LMF User Interface This chapter provides procedures for performing acceptance testing from the LMF Graphical User Interface (GUI) environment, the recommended method. The GUI provides the advantages of simplifying the LMF user interface, reducing the potential for mis-keying commands and associated parameters, and speeding up the execution of complex operations involving multiple command strings. If it is believed the LMF command line interface (CLI) will provide additional insight into ATP operation or unexpected test results, refer to LMF CLI Reference. Test Reports The CFE can choose to save the results of ATP tests to a report file from which ATP reports are generated for later printing. See the Generating an ATP Report section in this chapter. Test Equipment Selection Because test equipment functions during acceptance testing are controlled by the LMF directly, only the test equipment models supported by the LMF can be used. 1. Before using the LMF, read the Developer Release Notes for WinLMF section in the LMF Help function on-line documentation for any applicable information. Pay particular attention to the Caveats/Known Issues part of this appendix. 2. The ATP test is to be performed on out-of-service sectors only. 3. DO NOT substitute test equipment with other models not supported by the LMF. 4-2 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Introduction to ATP Test Equipment Set Calibration Refer to Test Set Calibration on page 3-55,Cable Calibration on page 3-64, and Appendix D Test Equipment Preparation for detailed interconnection information needed for calibrating equipment, cables, and other test equipment set components. Equipment has been factory-tested for FCC compliance. If license-governing bodies require documentation supporting UBS site compliance with regulations, a full ATP may be necessary. Perform the Reduced ATP only if reports for the specific UBS site are NOT required. After verifying that the proper operational software was code synced to the UBS, the CFE must perform these procedures (minimal recommendation): 1. Verify the TX/RX paths by performing TX Audit and Receive Signal Strength Indicator (RSSI) tests. 2. Be sure calibration data for all equipped sector-carriers is obtained and loaded on the OMC-R for normal site operation. Should failures occur while performing the specified tests, refer to the Basic Troubleshooting section of this manual for help in determining the failure point. Once the point of failure has been identified and corrected, refer to the FRU Optimization and ATP Test Matrix in Appendix B FRU Optimization/ATP Matrix to determine the applicable test that must be performed. In the unlikely event that the UBS passes these tests but has a forward link problem during normal operation, the CFE should then perform the additional TX tests for troubleshooting: TX spectral mask, TX rho, and TX code domain. 1x EV-DO ATP Should the UBS Macro be equipped with EV-DO cards/modules, refer to 1x EV-DO System ATP — 68P09283A59 for testing procedures. 68P09283A63-5 4-3 FOA AUG 2007 Acceptance Test Procedures - TX & RX Chapter 4: Acceptance Test Procedures Acceptance Test Procedures - TX & RX ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Reduced and Full ATP The full ATP (all the ATP tests) is optional. It is recommended that the reduced ATP be used. The reduced ATP consists of TX Audit and Receive Signal Strength Indicator (RSSI). TX Audit and RSSI Tests TX Audit The Audit is a power out test that will pass within +/-2 dB of the expected power. The standard pattern per S-C is 43dBm and the Audit test will pass if the output power is within the limits listed above. TX Audit Test Procedure Perform the procedure in Procedure 4-1 for TX Audit. Procedure 4-1 Procedure for TX Audit Set up test equipment for TX acceptance tests per Figure 3-23 through Figure 3-26 If it has not already been done, configure the test equipment for TX path audit as in Figure 3-23 Click on the devices to be tested. Click Tests > TX > TX Audit Select the appropriate carrier in the Channels/Carrier pick list. Enter the channel number in the Carrier # Channels box. To select multiple items, hold down the Shift or CTRL key while making the selections. Click OK. The status report window is displayed and then a Directions pop-up is displayed. Follow the cable connection directions as they are displayed. Test results are displayed in the status report window. Continued 4-4 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Acceptance Test Procedures - TX & RX Procedure 4-1 Procedure for TX Audit (Continued) Click Save Results or Dismiss button. If Dismiss is selected, the test results will not be saved. Figure 4-1 TX Audit Signal ti-cdma-TX_Audit.eps 68P09283A63-5 4-5 FOA AUG 2007 Acceptance Test Procedures - TX & RX Chapter 4: Acceptance Test Procedures Receive Signal Strength Indication Acceptance Test Overview This test verifies Receive Signal Strength Indication (RSSI) for the selected sectors to ensure integrity of the reverse (RX) path, that path losses are within tolerances required for correct receiver operation, and correct installation of the RX path. Testing is performed using the calibrated external test equipment as the signal source. The test equipment is controlled by the LMF during the test. The receive signal generated by the test equipment is injected into the sector RX path to be tested at the applicable UBS main and / or diversity receive ports. Equipment Operation During Testing The LMF sets the pilot channel power level of the sector for the selected sector to +XX dBm (measured at the TX port of the frame) and enables the sector-carrier on pilot channel only to enable the RX circuitry. The LMF then commands the test equipment to generate the receive signal on the selected carrier at -80 dBm as measured at the UBS RX port Test Measurements The power level of the received signal is measured by the RFX. The LMF corrects the measured power of the signal using the RX BLO and determines if the corrected signal gain is equal to or greater than the following specified criteria for the band in which the UBS operates: • 1900 MHz: –80 dBm (-86 dBm or greater) • 800 MHz: –80 dBm (-86 dBm or greater) The LMF provides -80 dBm signal (default) input to the UBS. The RSSI must be +/-6 dB. Receive Signal Strength Indicator ATP Perform the following procedure for RSSI acceptance testing. Procedure 4-2 Procedure for RSSI Acceptance Testing Set up the test equipment for RX acceptance tests. Reference Figure 3-23 through Figure 3-26. Select the carrier to be tested. In the LMF window menu bar, click on Tests > RX > RSSI Select the carrier to be tested in the Channels/Carriers pick list which is displayed. Continued 4-6 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Acceptance Test Procedures - TX & RX Procedure 4-2 Procedure for RSSI Acceptance Testing (Continued) Select the RX Branch to be tested from the choices in the drop down list provided (Both, Main, Diversity) Enter the appropriate power level into the Generator amplitude box (default: -80 dBm) Click OK. A status bar will be displayed followed by a Directions pop up window. Follow cable connection directions as they are displayed, and click the Continue button to begin testing. Progress will be indicated in the status bar. When the test is completed, click Save Results or Dismiss button, as required, in the Status Report window. If Dismiss is selected, then the test results will not be saved. Automated ATP This section covers the general requirements and procedures for conducting both automated ATP testing and performing individual ATP tests. Automated ATP Test Options Acceptance tests can be run individually or as one of the following automated groups: • All TX: TX tests verify the performance of the UBS transmit line up. • All RX: RX tests verify the performance of the UBS receiver line up. • All TX/RX: Executes all the TX and RX tests. • Full Optimization: Executes the TX calibration, downloads the BLO, and executes the TX audit before running all of the TX and RX tests. The Full Optimization test can be run if TX path calibration is needed before the TX and RX acceptance tests are run. The STOP button can be used to stop the testing process. The LMF is optimized to perform the tests as quickly as possible when selecting the “perform all" menu options. It is recommended that the user select this option on a per sector/carrier option where possible to save time. 68P09283A63-5 4-7 FOA AUG 2007 Acceptance Test Procedures - TX & RX Chapter 4: Acceptance Test Procedures Required Test Equipment The following test equipment is required: • LMF • Power Meter • Communications System Analyzer • Before connecting any test equipment directly to any UBS TX OUT connector, verify that there are no CDMA channels keyed. • At active sites, have the OMC-R operator place the carrier assigned to the UBS under test OOS. Failure to do so can result in serious personal injury and/or equipment damage. Test equipment must be calibrated and the cables re-calibrated before using them to perform acceptance tests. ATP Test Prerequisites Before attempting to run any ATP tests, ensure the following have been completed: • LMF is logged into the UBS. • All FRUs on the LMF screen are INS (Green) • Test cables are calibrated • Test equipment is connected for ATP tests (refer to ATP Test Setup illustrations in the Test Equipment Set Up section of Appendix E Optimization and Calibration Procedures) • Test equipment has been selected in the LMF, warmed up 60 minutes and calibrated • All required Ethernet test equipment connections are made • UBS transmit connectors are terminated with either non-radiating loads or connected to the test equipment as specified in Figure 3-27 through Figure 3-30. 4-8 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Acceptance Test Procedures - TX & RX Before a FER test is run, be sure that the following is done: All transmitter connectors are properly terminated. Terminations should be 50-Ohms, 200 W. Failure to observe these warnings may result in bodily injury or equipment damage. Procedure 4-3 Setup Test Equipment — TX Output Verify/Control Tests If it has not already been done, interface the LMF computer to the UBS. If it has not already been done, refer to Procedure 3-3 to start a GUI LMF session and log into the UBS. If it has not already been done, refer to Figure 3-23, Figure 3-24, Figure 3-25, or Figure 3-26 as applicable, for the test equipment and antennas being used, to connect test equipment for acceptance testing. LMF-based measurements factor in TX cable loss between the UBS and the test equipment. Antenna Connectors All acceptance testing requires test equipment connections to the UBS antenna TX or RX connectors. Refer to the ATP Test Setup illustrations in the Test Equipment Set Up section of Appendix E Optimization and Calibration Procedures for specific connection requirements Recommended Tests The recommended tests are TX Audit and Receive Signal Strength Indicator (RSSI) to confirm the physical assembly of the frame and that all the cables TX, RX, Digital etc are correctly connected. The rest of the tests are supported, optional, or for troubleshooting purposes. TX/RX ATP Test Procedure Follow the procedure in Procedure 4-4 to perform the All TX/RX ATP test. Procedure 4-4 All TX/RX ATP Test Procedure Continued 68P09283A63-5 4-9 FOA AUG 2007 Acceptance Test Procedures - TX & RX Chapter 4: Acceptance Test Procedures Set up the test equipment for abbreviated tests per Procedure 4-3 Select the device(s) to be tested. To select multiple items, hold down the Shift or Ctrl key while making the selections. For all TX tests except Code domain, a SectorCarrier must be selected. For code domain select the modem and carrier. For RX test — FER select the modem and SectorCarrier. For RX test — RSSI select SectorCarrier only. Click on Tests in the UBS Menu bar, and select All TX/RX ATP... from pull-down menu. Select the appropriate SectorCarrier (carrier-bts#-sector#-carrier#) displayed in the Channels/Carrier pick list. Since the UBS supports OMNI configurations only, sector# will always be 1. Verify that the correct channel number for the selected SectorCarrier is shown in the Carrier # Channels box. If not obtain the latest bts-#.necf files. If necessary, the correct number may be manually entered into the Carrier # Channels box. Select the appropriate RX Branch (Both, Main, or Diversity) from the drop-down menu. In the Rate Set box, select the appropriate data rate (1=9600, 2= 14400, 3 = 9600 1X) from the drop-down list. In the Test Pattern box, select the Standard test pattern from the drop down list in the Bay Level Offset Calibration section. Click on the OK button. The status report window and a Directions pop-up are displayed. Follow the cable connection directions as they are displayed. The test results are displayed in the status report window. Continued 4-10 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Acceptance Test Procedures - TX & RX Procedure 4-4 All TX/RX ATP Test Procedure (Continued) 10 Click on Save Results or Dismiss. If Dismiss is used, the test results will not be saved in the test report file. Figure 4-2 TX Test Options Screen en ter_filena me_her e_and_mo ve_per_st ep_8 Perform the procedure in Procedure 4-5 for all-inclusive transmit test. Procedure 4-5 All TX ATP Test Set up the test equipment for TX acceptance tests per Procedure 4-3 Continued 68P09283A63-5 4-11 FOA AUG 2007 Acceptance Test Procedures - TX & RX Procedure 4-5 Chapter 4: Acceptance Test Procedures All TX ATP Test (Continued) On LMF, select devices to be tested. To select multiple items, hold down the Shift or Ctrl key while making the selections. Click on Tests in the BTS Menu bar, and select All TX ATP... from pull-down menu. Select the appropriate carrier (HDModem) from those displayed in the Channels/Carrier pick list. Verify that the correct channel number for the selected carrier is shown in the Carrier # Channels box. If not obtain the latest bts-#.necf files. If necessary, the correct number may be manually entered into the Carrier # Channels box. In the Test Pattern box, select the Standard test pattern from the drop down list in the Bay Level Offset Calibration section. Other selections are available for TX Mask only. Click OK to display a status bar followed by a Directions pop-up window. Follow the cable connection directions as they are displayed, and click the Continue button to begin testing. As the ATP process is completed, results will be displayed in a status report window. Click the Save Results or Dismiss button. If Dismiss is used, the test results will not be saved in the test report file. 4-12 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Acceptance Test Procedures - TX & RX Perform the procedure in Procedure 4-6 for all-inclusive RX test. Procedure 4-6 All RX ATP Test Set up the test equipment for abbreviated acceptance tests per Procedure 4-3 On LMF, select devices to be tested. To select multiple items, hold down the Shift or Ctrl key while making the selections. Click on Tests in the UBS Menu bar, and select All RX Test... from pull-down menu. Select the appropriate carrier from those displayed in the Channels/Carrier pick list. Select the appropriate RX Branch (Both, Main, or Diversity) from the drop-down menu. In the Rate Set box, select the appropriate data rate (1=9600, 2= 14400, 3 = 9600 1X) from the drop-down list. Click OK to display a status bar followed by a Directions pop-up window. Follow the cable connection directions as they are displayed, and click the Continue button to begin testing. As the ATP process is completed, results will be displayed in a status report window. Click the Save Results or Dismiss button. If Dismiss is used, the test results will not be saved in the test report file. 68P09283A63-5 4-13 FOA AUG 2007 Individual Tests Chapter 4: Acceptance Test Procedures Individual Tests ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ TX and RX Testing The following individual ATP tests can be used to evaluate specific aspects of UBS operation against individual performance requirements. All testing is performed using the LMF GUI environment. TX Testing TX tests verify transmit antenna paths and output power control. All tests are performed using the external, calibrated test equipment. All measurements are made at the appropriate UBS TX OUT connector(s). TX tests verify TX operation of the entire CDMA forward link using selected sector-carriers assigned to respective sector antennas. Each sector-carrier is keyed up to generate a CDMA carrier (using BLO) at the NEC file-specified carrier output power level. RX Testing RX testing verifies receive antenna paths for the sector-carriers selected for the test. All tests are performed using the external, calibrated test equipment to inject a CDMA RF carrier with all zero long code at the specified RX frequency at the appropriate UBS RX IN connector(s). RX tests verify RX operation of the entire CDMA reverse link. Individual Tests Standard Pattern (per the 3GPP2 standard) - For UBS Macro, the standard pattern is the total digital gain of the signal (383) that includes the following channels (9 in all) and their individual digital gain: • Pilot -171 • Page - 165 • Sync - 83 • 6xTCH - 117 In the UBS Macro, the pilot is set to 36dBm, which brings the total power of this pattern to 43dBm - 7dB higher. Spectral Purity TX Mask This test verifies that the transmitted CDMA carrier waveform generated on each sector meets the transmit spectral mask specification with respect to the assigned NEC file values. 4-14 68P09283A63-5 FOA AUG 2007 1X UBS Macro BTS Optimization/ATP Individual Tests Waveform Quality (Rho) This test verifies the transmitted Pilot channel element digital waveform quality of each sector-carrier enabled at a specific frequency per the current NEC file assignment. All tests are performed using the external calibrated test set controlled by the same command. All measurements are via the appropriate TX OUT connector. Pilot Time Offset The Pilot Time Offset is the difference between the CDMA analyzer measurement interval (based on the UBS system time reference) and the incoming block of transmitted data from the UBS. Code Domain Power/Noise Floor This test verifies the Code Domain Power/Noise of each sector-carrier is enabled at a specific frequency per the current NEC file assignment. All tests are performed using the external calibrated test set controlled by the same command. All measurements are via the appropriate TX OUT connector. Frame Error Rate (FER) The Frame Error Rate (FER) test verifies RX operation of the entire CDMA Reverse Link using all equipped DMIs assigned to all respective sectors/antennas. This test verifies the UBS sensitivity on all traffic channel elements currently configured on all equipped DMIs at an RF input level of -123.0 dBm. TX Audit The TX Audit is a power out test that will pass within +/-2dB of the expected power. The standard power per S-C is 43dBm and the Audit test will pass, if the output power is within the limits listed above. Calibration It is optional, but supported. The calibration in UBS is always a negative number representing the LOSS between the output of the XMI to the top of the frame. In this frame, it is typically -1dB to –2dB depending on RF elements in the frame. 68P09283A63-5 4-15 FOA AUG 2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2009:01:09 14:22:28-07:00 Create Date : 2009:01:09 14:22:16-07:00 Metadata Date : 2009:01:09 14:22:28-07:00 Creator Tool : Adobe Acrobat 8.1 Combine Files Format : application/pdf Title : Creator : Motorola Gold Disk User Document ID : uuid:75ab82cd-87c3-46d7-88c8-fa0a6eee328b Instance ID : uuid:8b783f28-b1de-4a09-ad52-d401258ac556 Producer : Adobe Acrobat 8.1 Page Count : 86 Author : Motorola Gold Disk UserEXIF Metadata provided by EXIF.tools