Nokia Solutions and Networks T5JX1 UBS CDMA XMI Transceiver at 800 MHz User Manual Exhibit 8e

Nokia Solutions and Networks UBS CDMA XMI Transceiver at 800 MHz Exhibit 8e

Exhibit 8e

Preparing the LMF Chapter 3: LMF Oper ationFigure 3 -1 LMF F older Structureti-cdma-05823.epsTheloadsfolder and all the folders below it are no longer contained on the LMFCD as of LMF 2.9.0.0. When installing LMF software on a system that has nevercontained LMF software before, the user will need to create these folders manually .When installing a new version of LMF onto a PC already containing LMF software,any existing folders will be unaffected.WinLMF DirectoryThe CDMA LMF installation program creates the default home directory , c:\wlmf , and installs theapplication files and subdirectories (folders) in it. Because this can be changed at installation,the CDMA LMF home directory will be referred to with the generic convention of:<x>:\lmf home directory>Where:<x> = the LMF computer drive letter where the CDMA LMF home directory is located.<lmf home directory> = the directory path or name where the CDMA LMF is installed.3 -4 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Preparing the LMFWinLMF Operating System InstallationThis section provides information and instructions for installing and updating the LMF softwareand files.First Time Installation Sequence:1. Install Java Runtime Environment (JRE)2. Install U/WIN K -shell emulator (optional)3. Install LMF application programsAny time U/WIN is re -installed, the LMF application software must also bere -installed. This is because the LMF application installation modifies some ofthe files that are installed during the U/W in installation. These modifications arenecessary for proper LMF CLI operation.If required, a separate CD ROM of UBS Binaries may be obtained for binary updates.First Time Installation SequenceF ollow the procedure in Procedure 3 -1 to install the LMF application program using the LMFCD ROM.Procedure 3 -1 CD ROM Installation1Insert the LMF Program CD ROM into the LMF CD ROM drive.•If the Setup screen appears, follow the instructions displayed on thescreen.•If the Setup screen is not displayed, proceed to step 2 .2Click on the Start button.3Select Run .4Enter d:\autorun in the Open box and click OK .If applicable, replace the letter dwith the correct CD ROM driveletter .68P09283A63 -5 3 -5FOA A UG 2007
LMF to UBS Connection Chapter 3: LMF Oper ationLMF to UBS Connection■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■LMF to UBS ConnectionF ollow the procedure in Procedure 3 -2 to establish LMF to UBS connection.Procedure 3 -2 LMF to UBS Connection Procedure1V erify that the W inLMF computer has an Ethernet port.2V erify that a serial port (normally COM 1) is available for use.3Connect CDMA LMF to the UBS via the CRMS/LMT Customer ENET or DMILMT port.Figure 3 -2 LMF Connection Detailti-cdma-05842-A.epsCOM1 ConnectorLMF NOTEBOOK Ethernet Port Ethernet   Hub To CRMS / LMTTo GPIB BoxRS-232 Null Modem CableCUSTOMER ENET PortThe Ethernet hub is is used when the Ethernet interface on the LMF PC may not be able to keep a reliable ethernet link.  NOTE:or DMI LMT Port(if CRMS is in use)3 -6 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFUsing WinLMF■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Basic WinLMF OperationLMF Coverage in This Publication — All references to the LMF in this publication are for theCDMA application programOperating Environments — The LMF application program allows the user to work in the twofollowing operating environments which are accessed using the specified desktop icons:•Graphical User Interface (GUI) using the W inLMF with UBS Support icon•Command Line Interface (CLI) using the W inLMF CLI UBS iconCLI can be run if the GUI is already running.Basic Operation — The GUI is the primary optimization and acceptance testing operatingenvironment. The CLI environment provides additional capability to the user to performmanually controlled acceptance tests and audit the results of optimization and calibrationactions. Both operations allow the following:•Selecting and deselecting UBS devices•Unlocking devices•Locking devices•Resetting devices•Obtaining device statusThe following additional basic operation can be performed in a GUI environment:•Sorting a status report window•Displaying the Electronic Identification (EID) information of the FRUsF or detailed information on performing these and other LMF operations, refer to the LMFOn -Line Help.Unless otherwise noted, LMF procedures in this manual are performed using theGUI environment.68P09283A63 -5 3 -7FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationOnline Help - T ask oriented online help is available in the LMF by clicking on Help from themenu bar .The LMF Display and the UBSUBS Display - When the LMF is logged into a UBS , a frame tab is displayed. The frame tab will belabeled withFrame, the UBS number , a dash, and the frame number (for example, Frame -812 -1for UBS 812, RFMF 1). There is only one frame for the UBS , so there will only be one tab.Graphical User Interface OverviewThe LMF uses a Graphical User Interface (GUI), which supports the following functions:•Selecting a device or devices•Selecting an action to apply to selected device(s)•Status report window displaying progress of actions taking place and related information•Notification when an action is complete and related information such as indication ofsuccess or failure•An OK button to close the status report window .Understanding GUI OperationF or detailed information on GUI operation and the LMF , refer to theLMF Help function on -linedocumentation.Command Line Interface OverviewThe LMF also provides Command Line Interface (CLI) capability . Activate the CLI by clicking ona shortcut icon on the desktop. The CLI can only be launched while the GUI is running.If the CLI tool wasNOTinstalled, it is possible to telnet to the CLI withoutthe UWIN tool by using the command line in windows ( RUN-> cmd ) and typingin the window after the LMF has already logged in: telnet localhost 9600appset newline value=23 -8 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFCLI Format ConventionsThe CLI command can be broken down in the following way:•verb•device including device identifier parameters•switch•option parameterskeywordsequal signsparameter valuesSpaces are required between the verb, device, switch, and option parameters. A hyphen is re-quired between the device and its identifiers. The following is an example of a UBS CLI command:configure sc -<bts#> -<sector#> -<carrier#> pgain=<pgain#>mdm_slot=<mdm_slot#> ce=<ce#> [pnoffset=<pnoffset#>]Refer to theW inLMF CDMA CLI Commands – 68P09275A12manual for further informationon CLI commands and their use.Logging into a UBSLogging into a UBS establishes a communications link between the UBS and the LMF . An LMFsession can be logged into only one UBS at a time.PrerequisitesBefore attempting to login to a UBS , ensure the following have been completed:•The LMF is properly connected to the UBS (see Figure 3 -2 )•The LMF application program is correctly installed and prepared•Preparing the LMF for Connectivity and Configuring the Controller of UBS proceduresare completed•The LMF computer was connected to the UBS before starting the W indows operatingsystem and LMF software. If necessary , restart the computer after connecting it to theUBS in accordance with Procedure 3 -3 and Figure 3 -2 .•When the PC has completed startup, click on WinLMF with UBS Support icon Figure 3 -3to bring up the Local T erminal window ( Figure 3 -4 )•IP Address is 128.0.0.xxx•Netmask address is 255.255.255.128•BlackICE or other similar process is disabled•W indowInternet Connection Firewalland other firewall programs should be disabled•Java Runtime Environment (JRE) is installed and version matched68P09283A63 -5 3 -9FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -3 WinLMF Iconti-cdma-LMF_UBS_Support.epsFigure 3 -4 Local T erminal (Login Screen)ti-cdma-06193.eps3 -10 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFUBS Login from the GUI EnvironmentF ollow the procedure in Procedure 3 -3 to log into a UBS when using the GUI environment.Procedure 3 -3 UBS GUI Login ProcedureThe LMF computer Network Interface Card (NIC) IPaddress is set to 128.0.0.48, subnetmask 255.255.255.128.Ping UBS fr ame (128.0.0.2) from PC (128.0.0.48)Disable/Stop all rew alls and other applications (e.g.BlackICE) which ma y block UDP / T CP tr ansfers.Disable all activ e F TP serv ers running on the PC.T erminate process called inetd.exe if it is running.NO TE: inetd32.exe ma y be activ e and doesn’ t require termination1Start the CDMA LMF GUI environment by double clicking on the W inLMFwith UBS Support desktop icon (if the LMF is not running). See Figure 3-4F or the first connection the user may be prompted about FTPserver localization on PC and choose the Ethernet adapter .2AChoose Network Interfacewindow will appear asking for IP Address of theNetwork Interface Card (NIC) of the element under test. See Figure 3-5 .3ASetting FTP Server root for Local T erminalwindowwill appear to asking for the path to the root directory .F or the typical LMF installation, the default Server Root path is C:\wlmf .See Figure 3-6 .4AFrame Selectionwindow will appear asking for type of UBS under test.See Figure 3-75A window similar to Figure 3-8 should appear .6Click on BTS . A drop down menu appears.Select Enter invasive mode . See Figure 3-97A message window appears stating that invasive mode is successful. SeeFigure 3-10 .68P09283A63 -5 3 -11FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -5 Network Interface Selectionti-cdma-01683.eps-3 -12 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -6 F TP Serv erti-cdma-06188.eps-68P09283A63 -5 3 -13FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -7 Fr ame Selectionti-cdma-01687.eps-3 -14 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -8 Local T erminal GUIti-cdma-06194.eps-68P09283A63 -5 3 -15FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -9 In v asiv e Mode Selectionti-cdma-06190.eps3 -16 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -10 In v asiv e Mode Message Windowti-cdma-06189.eps68P09283A63 -5 3 -17FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationLMF Menus and OptionsThe following figures display the menus and options available to the user .Figure 3 -11 displays the selections available under the BTS menu.Figure 3 -11 B T S Menuti-cdma-01682.eps3 -18 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -12 displays the choices that can be selected for testing.Figure 3 -12 Select Menuti-cdma-06198.eps68P09283A63 -5 3 -19FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -13 displays the actions for the DMI.Figure 3 -13 Device Menu - DMI (HDModem)ti-cdma-01685.eps3 -20 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -14 displays the actions for the XMI.Figure 3 -14 Device Menu - XMIti-cdma-01686.eps68P09283A63 -5 3 -21FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -15 displays the choices for the manually configuring equipment.Figure 3 -15 T ools Menu - Optionsti-cdma-06201.eps3 -22 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -16 displays the receive tests for the UBS .Figure 3 -16 T ests Menu - RXti-cdma-06199.eps68P09283A63 -5 3 -23FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -17 displays the transmit tests for the UBS .Figure 3 -17 T ests Menu - TXti-cdma-06200.eps3 -24 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -18 through Figure 3 -21 display the various UTIL menu choices that allow analysis ofthe UBS under test.Figure 3 -18 Util Menu - P ower Meterti-cdma-06204.eps68P09283A63 -5 3 -25FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -19 Util Menu - T est Equipmentti-cdma-06205.eps3 -26 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFFigure 3 -20 Util Menu - Examineti-cdma-06203.eps68P09283A63 -5 3 -27FOA A UG 2007
Using WinLMF Chapter 3: LMF Oper ationFigure 3 -21 Util Menu - Editti-cdma-06202.epsLogging OutLogging out of a UBS can only be accomplished from the Graphical User Interface (GUI) mode.The GUI and CLI environments use the same connection to a UBS . If a GUI and theCLI session are running for the same UBS at the same time, logging out of the UBSenvironment will log out of it for both.3 -28 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Using WinLMFLogging Out of a UBS from the GUI EnvironmentF ollow the procedure in Procedure 3 -4 to logout of a UBS when using the GUI environment.Procedure 3 -4 UBS GUI Logout Procedure1Click on File on the Local T erminal menu bar .2Click the Exit item in the pull-down menu.UBS will perform a soft reset.Anytime the LMF is exited from the UBS , the DMI controller(s)will automatically reboot within 1 minute in order to clear out anytest configurations and boot up under the original configuration inthe NECB and NECJ files.On -Line HelpT ask oriented on -line help is available in the LMF by clicking on Help in the window menu bar ,and selecting LMF Help from the pull–down menu.Figure 3 -22 Help Screenti-ccdma-06191.eps68P09283A63 -5 3 -29FOA A UG 2007
Download Code to UBS Chapter 3: LMF Oper ationDownload Code to UBS■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■The process of downloading code to a UBS consists of two principal steps:1. Code transfer to the UBS followed by distribution to the devices2. Code activationNormally , the OMC -R will download code to the UBS through the span line once the UBS isconfigured to establish communication with the OMC -R. However , there may be some occasionsthat the LMF may be used to download load instead, such as at a staging location used topre -load replacement DMIs with same code load version required by OMC -R. Then, when thenew DMI is taken to the site, it will integrate and synchronize much faster with the OMC -R.When the code is activated, the UBS will re–start, and the LMF will lose contact with the UBS .It will be necessary to log into the UBS again after the UBS devices complete initializationwith the new code.PrerequisitesThe following must be accomplished before downloading code:•Abts–#folder has been created for the UBS in the cdma subdirectory of the LMF homedirectory . (Refer to W inLMF File Structure Overview on page 3 - 3 )•The currentNECB -<software_release#>—bts#.xml andNECJ -<software_re-lease#>—bts#.xmlfiles for the UBS are saved in the UBSbts–#folder•The LIF .xml file and code and data binary files for the software release are saved in thecdma\loads\<software_release#>subdirectory folder of the LMF home directory , where<software_release#>is the number of the software release installed on the BS S . The<software_release#> should be the same as defined in the NECB/NECJ files•The LMF is logged into the UBS in invasive modeIf W inZip is used to unzip codeload, please be sure to uncheck the CR/LF conversionon the W inZip tool: From W inZip window , select Options -> Configuration ->Miscellaneous and unchecked T AR file smart CR/LF conversion box.Download ProcedureCode files are downloaded to the UBS using an FTP server . The user is given a choice of usingthe built–in LMF FTP server or an external FTP server . F or initial download of a UBS , the built–inFTP server in the LMF should be used. This procedure covers using the LMF built–in FTP server .3 -30 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Download Code to UBSThe UBS code load should always be synchronized with the download from theOMC -R before leaving the UBS site. Refer to Reset All Devices and Initialize SiteRemotely on page 5 - 8 for the procedure to do this.Procedure 3 -5 Download Code1In the menu bar of the Local T erminal BTS window , select BTS > Download Code...2If prompted that the “F ollowing operation may overwrite NECB, NECJ , LIF , and calibrationfiles on the BTS”, click Y es .3In the dialog box which appears, if the Use Local FTP server checkbox is not checked, clickin it to select this option.Result: A check mark will appear in the box.4In field labeled Software version enter the <software_release#> as specified in theprerequisite section (for example, 2.19.0.0.20).5If a “clean download” is required (download every file, even if they are the same as thosecurrently installed on the UBS), click in the P erform clean load checkbox.Result: A check mark will appear in the box.6Click Ok to start the download.Code download can require up to 40 minutes to complete.7When the download is complete, click Ok to close the status report window .When the code load is complete, the UBS will re–start, and the LMF will losecontact with the UBS .8Log the LMF into the UBS again.68P09283A63 -5 3 -31FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationTest Equipment Set Up■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Connecting Test Equipment to the UBSThe following equipment is required to perform optimization:•LMF•Communications system analyzer model supported by the LMF•Non -radiating transmit line termination load•Directional coupler and in -line attenuator•RF cables and connectors•Null modem cable (see Figure 1 -1 )•GPIB interface boxThe following figures provide representative illustrations of connections for test equipmentcurrently supported by the LMF :•Figure 3 -23 ,Figure 3 -24 ,Figure 3 -25 , and Figure 3 -26 show the test set connectionsfor TX calibration.•Figure 3 -27 ,Figure 3 -28 ,Figure 3 -29 , and Figure 3 -30 show test set connections foroptimization/A TP tests.•Figure 3 -31 ,Figure 3 -32 ,Figure 3 -33 , or Figure 3 -34 illustrate cable calibration test set–up.Test Equipment GPIB Address SettingsAll test equipment except the Agilent E7495A andAnritsuMT8212B is controlled by the LMFthrough an IEEE -488/GPIB bus. T o communicate on the bus, each piece of test equipment musthave a GPIB address set which the LMF will recognize. The standard address settings used bythe LMF for the various types of test equipment items are as follows:•Signal generator address: 1•P ower meter address: 13•Communications system analyzer: 18Using the procedures included in the Setting GPIB Addresses section of Appendix D T estEquipment Preparation , verify and, if necessary , change the GPIB address of each piece of testequipment used to match the above.3 -32 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpSupported Test EquipmentOptimization and A TP testing for CDMA2000 1X sites or carriers may be performed using thefollowing test equipment:•Advantest R3267 Analyzer with Advantest R3562 Signal Generator•Agilent E4406A with E4432B Signal Generator•Agilent 8935 series E6380A communications test set (formerly HP 8935) with option 200or R2K and with E4432B signal generator for 1X FER•Agilent E7495A or Agilent E7495B communications test setsThe E4406A/E4432B pair , or the R3267/R3562 pair , should be connected together using a GPIBcable. In addition, the R3562 and R3267 should be connected with a serial cable from the SerialI/O to the Serial I/O . This test equipment is capable of performing tests in both IS -95 A/B modeand CDMA 2000 mode if the required options are installed.T o prev ent damage to the test equipment, all TX test connections must be through thedirectional coupler and in -line attenuator as shown in the test setup illustr ations.Optional test equipmentA spectrum analyzer , such as the HP8594E, and a signal generator supporting the requiredfrequency ranges can be used to perform manual cable calibration.68P09283A63 -5 3 -33FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationTest Equipment PreparationSee Appendix D T est Equipment Preparation for specific steps to prepare each type of testset and power meter to perform calibration and A TP . The Agilent E7495A communicationstest set requires additional setup and preparation. This is described in detail in Appendix DT est Equipment Preparation .Calibration of the communications test set (or equivalent test equipment) must beperformed at the site before calibrating the overall test equipment set. Calibrate thecommunications test set after it has been allowed to warm up and stabilize for aminimum of 60 minutes.If an y piece of the test equipment set (for example, test cable, RF adapter) hasbeen replaced, the test equipment set must be re–calibr ated. F ailure to do so couldintroduce measurement errors, resulting in incorrect measurements and degr adationto system performance.Equipment Warm -upW arm -up UBS equipment for aminimum of 60 minutesprior to performing the UBS optimizationprocedure. This assures UBS site stability and contributes to optimization accuracy .Time spent running initial power -up, hardware/firmware audit, and UBS downloadcounts as warm -up time.Before connecting an y test equipment directly to an y UBS TX or duplex ed TX/RXconnector (for example, the TX/RX M connectors for a UBS equipped with IDRFs),v erif y there are NO channels k ey ed. A t activ e sites, ha v e the OMC –R place the carriersassigned to the XMI under test OOS . F ailure to do so can result in serious personalinjury and/or equipment damage.3 -34 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpAutomatic Cable CalibrationRefer to Calibrate T est Cabling using Communications System Analyzer on page 3 - 64 forautomatic cable calibration procedures using a communications test set.Manual Cable CalibrationIf manual cable calibration is required, refer to Calibrate T est Cabling Using Signal Generator &Spectrum Analyzer on page 3 - 69 for procedures to use a spectrum analyzer and signal generator .Set -up for TX CalibrationFigure 3 -23 ,Figure 3 -24 ,Figure 3 -25 , and Figure 3 -26 show test set connections for TXcalibration.68P09283A63 -5 3 -35FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationFigure 3 -23 TX Calibr ation T est Setup – Agilent 8935ti-cdma-06170.epsAGILENT 8935 SERIES E6380A (FORMERLY HP 8935)TEST SETS TRANSMIT (TX) SET UPRF IN/OUTHP-IBTO GPIBBOXRS232-GPIBINTERFACE BOXGPIBCABLECOMMUNICATIONSTEST SETCONTROLIEEE 488GPIB BUSUNSHIELDED TWISTEDPAIR (UTP) CABLE(RJ45 CONNECTORS)RS232NULLMODEMCABLEOUTS MODEDATA FORMATBAUD RATEGPIB ADRSG MODEONTEST SETINPUT/OUTPUTPORTS100-WATT (MIN)NON-RADIATINGRF LOADINCDMALMFDIP SWITCH SETTINGSTX TESTCABLEPOWERMETER(OPTIONAL)*ADVANTEST MODEL R3465INPUT50-OHMGPIBCONNECTS TOBACK OF UNIT* A POWER METER CAN BEUSED IN PLACE OF THECOMMUNICATIONS TEST SETFOR TX CALIBRATION/AUDITPOWERSENSOR10 DB MINIMUMIN-LINE ATTENUATORINTERNAL OR PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)50 ΩTERM.30 DBDIRECTIONALCOUPLERORTX TESTCABLETX TESTCABLEUBSCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIRX DIVTX/RX M(DUPLEXED TXAND RX)IDRF3 -36 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpFigure 3 -24 TX Calibr ation T est Setup – Agilent E4406A and Adv antest R3267ti-cdma-06171.epsTEST SETS TRANSMIT (TX) SET UPRS232-GPIBINTERFACE BOXGPIBCABLECOMMUNICATIONSTEST SETCONTROLIEEE 488GPIB BUSUNSHIELDED TWISTEDPAIR (UTP) CABLE(RJ45 CONNECTORS)RS232NULLMODEMCABLEOUTS MODEDATA FORMATBAUD RATEGPIB ADRSG MODEONTEST SETINPUT/OUTPUTPORTS100-W ATT (MIN)NON-RADIA TINGRF LOADINTX TESTCABLECDMALMFDIP SWITCH SETTINGSPOWERMETER(OPTIONAL)** A POWER METER CAN BEUSED IN PLACE OF THECOMMUNICATIONS TEST SETFOR TX CALIBRATION/AUDITPOWERSENSORRF ININTERNAL OR PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)50 ΩTERM.30 DBDIRECTIONALCOUPLERADVANTEST MODEL R3267AGILENT E4406ARF INPUT50 Ω1O DB MINIMUMIN-LINE ATTENUATORTX TESTCABLETX TESTCABLEORUBSCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIRX DIV TX/RX M(DUPLEXED TXAND RX)IDRF68P09283A63 -5 3 -37FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationFigure 3 -25 TX Calibr ation T est Setup – Agilent E7495Ati-cdma-06172.epsTEST SETS TRANSMIT (TX) SET UPCDMALMF50 ΩTERM.TX TESTCABLE30 DBDIRECTIONALCOUPLER100-W ATT (MIN.)NON-RADIA TINGRF LOADPOWERSENSOR1O DB MINIMUMIN-LINE ATTENUATORETHERNET HUBUNSHIELDED TWISTED PAIR (UTP)CABLE (RJ45 CONNECTORS)AGILENT  E7495APORT 2RF INSYNC MONITOREVEN SEC TICKPULSE REFERENCEFROM SSI TREF OUTUse onlyAgilent suppliedpower adapterGPSGPIOSerial 1Serial 2Power REF50 MHzSensorExt RefInEven SecondSync InAntennaPort 1RF Out / SWRPort 2RF InINTERNALETHERNETCARDCOMMUNICATIONSSYSTEM ANALYZERPOWER METERPORT 2RF INPORT 1RF OUTINTERNAL OR PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)ORTX TESTCABLETX TESTCABLENOTES:1. WHEN USING THE E7495A, TX TESTSREQUIRE A MINIMUM OF 30 DBATTENUATION PLUS THE CABLELOSSES.2. IF BTS IS EQUIPPED WITH DRDCS(DUPLEXED RX/TX SIGNALS), CONNECTTHE TX TEST CABLE TO THE DRDCANTENNA CONNECTOR.UBSCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIRX DIV TX/RX M(DUPLEXED TXAND RX)IDRF3 -38 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpFigure 3 -26 TX Calibr ation T est Setup – Anritsu MT8212BTEST SETS TRANSMIT (TX) SET UPCDMALMF50 ΩTERM.TX  ANDRX TESTCABLE30 DBDIRECTIONALCOUPLER100-W ATT (MIN.)NON-RADIA TINGRF LOAD1O DB MINIMUMIN-LINE ATTENUATORINTERNAL OR PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)UNSHIELDED TWISTED PAIR (UTP)CABLE (RJ45 CONNECTORS)SERIALINTERFACECOMMUNICATIONSSYSTEM ANALYZERRF IN50 ΩRF OUT50 ΩRF IN50 ΩANRITSU MT8212BTX  ANDRX TESTCABLERS232 SERIALINTERFACE CABLESERIALINTERFACECONNECTORUBSCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIRX DIV TX/RX M(DUPLEXED TXAND RX)IDRFtti-cdma-06206.eps68P09283A63 -5 3 -39FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationSetup for ATPFigure 3 -27 ,Figure 3 -28 ,Figure 3 -29 , and Figure 3 -30 show test set connections for A TP tests.3 -40 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpFigure 3 -27 A TP T est Setup – Agilent E4432B/8935 and Agilent E4432B/E4406Ati-cdma-06174.epsTEST SETS OPTIMIZATION/ATP SET UPRF INPUT50 ΩRFOUTPUT50 ΩAGILENT E4432B (TOP) AND E4406A(BOTTOM)FREQ MONITOR19.6608 MHZ CLOCKREFERENCE FROMSSI FREF OUTSYNC MONITOR EVENSEC TICK PULSEREFERENCE FROMSSI TREF OUTBNC“T”TOTRIGGER INON REAR OFTRANSMITTERTESTERTOPATTERN TRIGIN ON REAR OFSIGNALGENERATORTOEXT REF INON REAR OFTRANSMITTERTESTERNOTE:10 MHZ IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO10 MHZ OUT (SWITCHED) ON REAR OF TRANSMITTER TESTERRS232-GPIBINTERFACE BOXGPIBCABLERS232 NULLMODEMCABLES MODEDATA FORMATBAUD RATEGPIB ADRS G MODEONUBSCDMALMFDIP SWITCH SETTINGS *CRMS/LMTCUSTOMERENETCOMMUNICATIONSSYSTEM ANALYZERHP-IBORGPIBFREFOUTTREFOUTSSISIGNALGENERATORGPIB10 MHZIN10 MHZREF OUTOR10 MHZOUTTRIGGER INOREVEN SECSYNCH INEXTREFINBNC“T”PATTERNTRIG IN* BLACK RECTANGLESREPRESENT THERAISED PART OFSWITCHESTX/RXTESTCABLERF IN/OUTORRF INPUT50 ΩRF OUTPUT 50 ΩAGILENT  E4432B (TOP) AND 8935 SERIES E6380A(BOTTOM)SYNC MONITOREVEN SEC TICKPULSE REFERENCEFROM SSI TREF OUFREQ MONITOR19.6608 MHZ CLOCKREFERENCE FROMSSI FREF OUTRFOUTPUT50 ΩNOTES:10 MHZ IN ON REAR OF SIGNAL GENERATOR IS CONNECTED TO10 MHZ REF OUT ON SIDE OF CDMA BASE STATION TEST SET PATTERN TRIG IN ON REAR OF SIGNAL GENERATOR ISCONNECTED TO EVEN SECOND SYNC IN ON SIDE OF CDMABASE STATION TEST SET.RFIN/OUTBNC“T”UNSHIELDED TWISTED PAIR(UTP) CABLE(RJ45 CONNECTORS)INTERNAL PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)RX DIVTX/RX M(DUPLEXED TXAND RX)50 ΩTERM.DIRECTIONALCOUPLER(30 DB)100-W ATT (MIN.)NON-RADIATINGRF LOADTX TEST: 1O DB MINIMUMIN-LINE ATTENUATORORIDRFTX/RX TESTCABLE68P09283A63 -5 3 -41FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationFigure 3 -28 A TP T est Setup – Adv antest R3267/3562ti-cdma-06173.epsTEST SETS OPTIMIZATION/ATP SET UPINPUT 50 ΩRF OUT50 ΩAdvantest R3267 (Top) and R3562 (Bottom)FREQ MONITOR19.6608 MHZ CLOCKREFERENCE FROMSSI FREF OUTSYNC MONITOREVEN SEC TICKPULSE REFERENCEFROM SSI TREF OUTBNC“T”NOTE:SYNTHE REF IN ON REAR OF SIGNAL GENERATOR ISCONNECTED TO 10 MHZ REF OUT ON REAR OFSPECTRUM ANALYZERTOEXT TRIGON REAR OFSPECTRUMANALYZERRS232-GPIBINTERFACE BOXGPIBCABLERS232 NULLMODEMCABLES MODEDATA FORMATBAUD RATEGPIB ADRSG MODEONCDMALMFDIP SWITCH SETTINGSINPUT50 ΩRF OUT50 ΩBNC“T”SPECTRUMANALYZERGPIBSIGNAL GENERATORGPIBSYNTHEREFIN10 MHZOUTEXTTRIG INMOD TIMEBASE INEXT TRIG* BLACK RECTANGLESREPRESENT THE RAISEDPART OF SWITCHESUNSHIELDED TWISTEDPAIR (UTP) CABLE(RJ45 CONNECTORS)INTERNAL PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)TX/RXTESTCABLE50 ΩTERM.DIRECTIONALCOUPLER(30 DB)100-W ATT (MIN.)NON-RADIATINGRF LOADTX TEST: 1O DB MINIMUMIN-LINE ATTENUATORORTX/RX TESTCABLEUBSCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIRX DIVTX/RX M(DUPLEXED TXAND RX)IDRF3 -42 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Set UpFigure 3 -29 A TP T est Setup – Agilent E7495A or E7495Bti-cdma-06175.epsTEST SET ATP TEST SET UPUNSHIELDED TWISTED PAIR (UTP)CABLE (RJ45 CONNECTORS)CDMALMFINTERNALETHERNETCARDRF INPUT 50 ΩOR INPUT 50 ΩCOMMUNICATIONSSYSTEM ANALYZER50 ΩTERM.TX/RXTEST30 DBDIRECTIONALCOUPLER100-W ATT (MIN.)NON-RADIA TINGRF LOAD TX TESTTX TEST: 1O DB MINIMUMIN-LINE  ATTENUATORETHERNET HUBRX TESTTESTCABLESNOTE:  USE THE SAMECABLE SET FOR TX AND RXATP. SWITCH THE CABLESDURING ALL ATP TESTS ASSHOWN.PORT 2RF INPORT 1RF OUTAGILENT E7495A or E7495BPORT 1RF OUTPORT 2RF INSYNC MONITOREVEN SEC TICKPULSE REFERENCEFROM SSI TREF OUTUse onlyAgilent suppliedpower adapterGPSGPIOSerial 1Serial 2Power REF50 MHzSensorExt RefInEven SecondSync InAntennaPort 1RF Out / SWRPort 2RF InINTERNAL PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)POWER METER(SEE NOTE FOR RX TEST ATTENUATION SELECTION)NOTE: FOR RX TESTING, TOTAL RF PATHATTENUATION (CABLES+COUPLERS+ATTENUATORS)MUST BE WITHIN THE FOLLOWING VALUESSPECIFIED FOR EACH TYPE OF TEST SET:E7495A: 25 TO 32 dBE7495B: 10 TO 100 dB2. WHEN USING THE E7495A, TX TESTS REQUIRE AMINIMUM OF 30 DB ATTENUATION PLUS THE CABLELOSSES.3. USE THE SAME CABLE SET FOR TX AND RX ATP.SWITCH THE CABLES DURING ALL ATP TESTS ASSHOWN.4. IF BTS IS EQUIPPED WITH DUPLEXED RX/TXSIGNALS, CONNECT THE TX TEST CABLE TO THEDUPLEXED ANTENNA CONNECTOR.EVEN SECONDSYNC INUBSRX DIV TX/RX M(DUPLEXED TXAND RX)IDRFCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSI68P09283A63 -5 3 -43FOA A UG 2007
T est Equipment Set Up Chapter 3: LMF Oper ationFigure 3 -30 A TP T est Setup – Anritsu MT8212BTEST SET OPTIMIZATION/ATP SET UPCDMALMFINTERNAL OR PCMCIA ETHERNETNETWORK INTERFACE CARD (NIC)UNSHIELDED TWISTED PAIR (UTP)CABLE (RJ45 CONNECTORS)SERIALINTERFACECOMMUNICATIONSSYSTEM ANALYZERRF IN50 ΩRF OUT50 ΩSYNC MONITOREVEN SEC TICKPULSE REFERENCEFROM SSI TREF OUTRF IN50 ΩFREQ MONITOR19.6608 MHZ CLOCKREFERENCE FROMSSI FREF OUTANRITSU MT8212BRF OUT50 ΩTX TESTRX TESTRS232 SERIALINTERFACE CABLENOTES:1. USE THE SAME CABLE SET FOR TXAND RX ATP. SWITCH THE CABLESDURING ATP TESTS AS SHOWN.2. FOR RX TESTING (RSSI), TOTAL RFPATH ATTENUATION(CABLES+COUPLERS+ATTENUATORS)MUST BE 65 dB OR GREATER.SERIALINTERFACECONNECTOR100-W ATT (MIN.)NON-RADIA TINGRF LOADUBSRX DIVTX/RX M(DUPLEXED TXAND RX)IDRFCRMS/LMTCUSTOMERENETFREFOUTTREFOUTSSIti-cdma-06207.eps3 -44 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Connection to the LMFTest Equipment Connection to the LMF■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Test Equipment ConnectionThe LMF computer platform provides two types of hardware interfaces which support threedifferent test equipment communication methods.•The COM hardware interface (RS -232) supports connection with both of the followingcommunication methods:General Purpose Interface Bus (GPIB)Direct serial connection•The Ethernet interface supports the network test equipment communication method.Additional information on each interface type is provided in the following subsections.COM Port InterfaceThe LMF computer RS -232 serial bus interfaces are designated as COM connections or ports insoftware. These interfaces support communication with test equipment connected to the LMFcomputer either directly with a serial cable or through a GPIB interface device (GPIB box). TheLMF normally uses COM1 for the interface. COM2 is not used unless the LMF computer hastwo RS -232 connectors. The COM port selected in the LMF can not be used for any otherpurpose when the LMF is using it.Selecting the COM port - P erform the following to select a COM port for use with testequipment needing either a GPIB or a direct serial connection:Procedure 3 -6 Selecting a COM P ort for GPIB or Serial T est Equipment Connection1From the LMF window menu bar select T ools >Options .Result: The LMF Options window opens.2If the T est Equipment tab is not in the forefront, click the tab to bring it forward.3Click in the COM radio button in the GPIB/COM settings area.Result: A black dot appears in the circle.4Select the COM port to use (normally COM1) from the dropdown in the P ort: box ofthe GPIB/COM settings area.5Click the Save button to save the selection configuration for future LMF sessions.6Click the Close button to close the LMF Options window .68P09283A63 -5 3 -45FOA A UG 2007
T est Equipment Connection to the LMF Chapter 3: LMF Oper ationDisconnecting and Reconnecting the LMF and the COM port - The LMF can bedisconnected from the active COM port by using the Disconnect P or t button in the GPIB/COMsettings area of the T est Equipment tab. Disconnecting the LMF may be needed, for example,to use a HyperT erminal connection for a hardware Man Machine Interface (MMI) communicationsession. P erform the following to disconnect or reconnect the LMF and the selected COM port.Procedure 3 -7 Disconnect and R econnect the LMF and the Activ e COM P ort1From the LMF window menu bar select T ools >Options .Result: The LMF Options window opens.2If the T est Equipment tab is not in the forefront, click the tab to bring it forward.3Disconnectthe LMF from the active COM port: click the Disconnect Port button inthe GPIB/COM settings area.4Reconnectthe LMF to the active COM port: click the Detect button in the GPIB T estequipment or Serial T est Equipment area.5If no other operations are required in the LMF Options window click Close to closethe window .Ethernet InterfaceThe LMF computer Ethernet interface supports communication with test equipment whichuses the network connection method. This interface uses Internet Protocol (IP) addressing todifferentiate each node on the network. Motorola recommends that the Ethernet connection bedone through an Ethernet hub. The hub connects to the LMF computer , the test equipment, andthe base station Local Area Network (LAN). Connection details are as follows:T est equipment to hub – This is an Unshielded T wisted P air (UTP) Ethernet cable with two10/100Base–TX 8 -contact modular connectors.LMF to hub – Use one of the following cable types to connect the LMF to the Hub:•Ethernet cable. Be sure the computer Network Interface Card (NIC) is set for either AUTOor to use the 8–contact modular connector only .•Coaxial cable between NIC and Hub. F or a computer NIC equipped with a 10Base–2 (BNC)connector , use a BNC tee connector on the hub. If the hub does not have BNC connectors,use a BNC–to–UTP adapter with the tee connector . Connect a coaxial cable between theNIC and one end of the BNC tee crossbar .Hub to base station– Use one of the following, depending on the type of base station to becalibrated or tested:•F or UBS with 10/100Base–T LAN : Connect an Ethernet cable between the hub and the S SICRMS/LMT CUSTOMER ENET connector .3 -46 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment Connection to the LMFAddressing MethodsDifferent addressing methods are used for test equipment depending on the type of interfaceconnection it has. The different addressing methods are described in the following subsections.GPIB AddressesGPIB addresses can range from 1 through 30. The LMF will accept any address in thatrange, but the numbers entered in the LMF Options window GPIB address box must matchthe addresses set in the test equipment. Motorola recommends using 1for a CDMA signalgenerator , 13 for a power meter , and 18 for a communications system analyzer . T o verifyand, if necessary , change the GPIB addresses of the test equipment, refer to theSetting GPIBAddressessections of Appendix D T est Equipment Preparation .Serial ConnectionThis connection type uses a direct serial connection between the test equipment and theLMF computer platform. TheAnritsuMT8212B communications test set is an example oftest equipment using this type of connection. There are no specific addressing requirementsfor this type of interface.IP AddressesT est equipment using the Network connection type use IP addresses to identify them on theEthernet LAN . The E7495A and E7495B communications test sets are examples of Networkconnection test equipment. Setting the IP address in the test equipment is covered in thespecific test equipment (for example, Agilent E7495) set -up section of Appendix D T estEquipment Preparation .68P09283A63 -5 3 -47FOA A UG 2007
T est Equipment Selection Chapter 3: LMF Oper ationTest Equipment Selection■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Test Equipment SelectionT est equipment selection is performed in the LMF Options window , accessed through T ools>Options in the LMF window menu bar . The window has four tabs covering differentcategories of options. T est equipment operations, including selection, are performed on theT est Equipment tab. F or software release 2.20.0.x (R20), the test equipment list displayed onthis tab is context sensitive based on the Connection type selected.•When GPIB is selected, only test equipment with a GPIB interface is displayed.•When Serial is selected, only test equipment needing a direct serial connection isdisplayed.•When Network is selected, only test equipment needing an Ethernet connection isdisplayed.Manual and Autodetect SelectionT est equipment can be manually specified before or after the test equipment is connected. TheLMF does not try to determine if the test equipment is actually connected for manual selection.The LMF can be commanded to automatically detect test equipment connected to it. Thisautodetection feature is operated by a Detect button located in the test equipment list area foreach connection type (GPIB, Serial, or Network).Selecting Test EquipmentThere is a different set of test equipment selection procedures for each test equipmentconnection type. These are:•GPIB connection•Serial connection•Network (Ethernet) connectionSelection ProceduresT est equipment selection procedures are contained in the following subsections. Eachsubsection is for a different connection type. Each subsection includes a procedure for manuallyspecifying test equipment items and a procedure to have the LMF automatically detect theconnected test equipment.3 -48 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment SelectionGPIB Interface Test Equipment Manual Selection and AutodetectionPrerequisites - The following must be done before performing these procedures:•LMF computer and test equipment are both correctly connected to the GPIB box•T est equipment is turned on•GPIB addresses set in the test equipment have been verified as correct using the applicableprocedures in Appendix D T est Equipment Preparation .Manual selection – T est equipment may be selected manually even if it is not connected tothe LMF .Procedure 3 -8 Manually Selecting T est Equipment - GPIB Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the GPIB radio button in the Connection T ype area.Result: A black dot appears in the circle.4Click the COM radio button in the GPIB/COM settings area.Result: A black dot appears in the circle.5Select the correct LMF computer serial port from the P ort: pick list (normally COM1 )(Refer to the T est Equipment Connection to the LMF on page 3- 45 section of this chapter).6In the GPIB T est equipment area click the checkbox(es) of the test equipment beingused.Result: Checkmarks appear in the boxes clicked on.7If one is not already displayed, type the GPIB address for each checkedpiece of test equipment in the corresponding box labeled GPIB .Recommended Addresses1= CDMA Signal generator13 = P ower Meter18 = CDMA AnalyzerWhen the test equipment items are manually selected, the CDMA analyzer isused only if a power meter is not selected.Continued68P09283A63 -5 3 -49FOA A UG 2007
T est Equipment Selection Chapter 3: LMF Oper ationProcedure 3 -8 Manually Selecting T est Equipment - GPIB Interface (Continued)8Click the Apply button. The button will darken until the selection is committed.9Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.A checkmarkappears in the box.10Click the Save button to save the selection configuration for future LMF sessions.11Click the Close button to close the LMF Options window .When two devices of the same type have been selected, a window will appearwarning that more than one signal generator/power meter/ analyzer has beenchosen. Click the Continue button to close this window . The checkbox can beclicked to prevent the window from being displayed again, if desired.Automatically Selecting T est Equipment (Autodetection) – When using theautodetection feature to select test equipment, the LMF determines which test equipment itemsare actually communicating with the LMF .Procedure 3 -9 A utodetecting T est Equipment - GPIB Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the GPIB radio button in the Connection T ype area.Result: A black dot appears in the circle.4Click the COM radio button in the GPIB/COM settings area.Result: A black dot appears in the circle.5Select the correct LMF computer serial port from the P ort: pick list (normally COM1 )(Refer to the T est Equipment Connection to the LMF on page 3- 45 section of this chapter).Continued3 -50 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment SelectionProcedure 3 -9 A utodetecting T est Equipment - GPIB Interface (Continued)6If they are not already displayed, enter the GPIB address for eachpiece of required test equipment, separated by commas, in theGPIB Addresses: box in the GPIB T est equipment area.Recommended Addresses1= CDMA Signal generator13 = P ower Meter18 = CDMA AnalyzerIn autodetection when both a power meter and a CDMA analyzer areselected, the LMF uses the first item that is capable of performing RF powermeasurement listed in the GPIB Addresses: box. The address for a CDMAsignal generator is normally 1, the address for a power meter is normally 13,and the address for a CDMA analyzer is normally 18 . If 1,13,18 is listedin the GPIB Addresses: box, the power meter ( 13 ) is used for RF powermeasurements. When the test equipment items are manually selected, theCDMA analyzer is used only if a power meter is not selected.7Click the Detect button. The button will darken until the selection is committed.Result: F or each detected equipment item, a check will appear in its checkbox and itsGPIB address will appear in its GPIB box.8Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.Result: A checkmark appears in the box.9Click the Save button to save the selection configuration for future LMF sessions.10Click the Close button to close the LMF Options window .When two devices of the same type have been selected, a window will appearwarning that more than one signal generator/power meter/ analyzer has beenchosen. Click the Continue button to close this window . The checkbox can beclicked to prevent the window from being displayed again, if desired.Serial Interface Test Equipment Manual Selection and AutodetectionPrerequisites – The following must be done before performing these procedures:•T est equipment is correctly connected to the LMF computer RS -232 connector witha serial cable•T est equipment is turned on68P09283A63 -5 3 -51FOA A UG 2007
T est Equipment Selection Chapter 3: LMF Oper ationManual selection – T est equipment may be selected manually even if it is not connected tothe LMF .Procedure 3 -10 Manually Selecting T est Equipment - Serial Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the Serial radio button in the Connection T ype area.Result: A black dot appears in the circle.4Click the COM radio button in the GPIB/COM settings area.Result: A black dot appears in the circle.5Select the correct LMF computer serial port from the P ort: pick list (normally COM1 )(Refer to the T est Equipment Connection to the LMF on page 3- 45 section of this chapter).6In the Serial T est equipment , area click the checkbox(es) of the test equipment beingused.Result: Checkmarks appear in the box(es) clicked on.7Click the Apply button. The button will darken until the selection is committed.8Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.Result: A checkmark appears in the box.9Click the Save button to save the selection configuration for future LMF sessions.10Click the Close button to close the LMF Options window .Automatically Selecting T est Equipment (Autodetection) – When using theautodetection feature to select test equipment, the LMF determines which test equipment itemsare actually communicating with the LMF .Procedure 3 -11 A utodetecting T est Equipment - Serial Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the Serial radio button in the Connection T ype area.Result: A black dot appears in the circle.Continued3 -52 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Equipment SelectionProcedure 3 -11 A utodetecting T est Equipment - Serial Interface (Continued)4Click the COM radio button in the GPIB/COM settings area.Result: A black dot appears in the circle.5Select the correct LMF computer serial port from the P ort: pick list (normally COM1 )(Refer to the T est Equipment Connection to the LMF on page 3- 45 section of this chapter).6Choose the test equipment on the Serial T est Equipment list by clicking thecorresponding checkbox.Result: A checkmark appears in the box.7Click the Detect button. The button will darken until the selection is committed.Result: F or each detected equipment item, a check will appear in its checkbox.8Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.Result: A checkmark appears in the box.9Click the Save button to save the selection configuration for future LMF sessions.10Click the Close button to close the LMF Options window .Network Interface Test Equipment Manual Selection and AutodetectionPrerequisites– The following must be done before performing these procedures:•Be sure that no other equipment is connected to the LMF .•T est equipment is correctly connected to the LMF computer through the Ethernet LAN•The IP address is set in the test equipment as specified in the test equipment model (forexample, Agilent E7495) set -up section of Appendix D T est Equipment Preparation .•T est equipment is turned onManual selection – T est equipment may be selected manually even if it is not connected tothe LMF .Procedure 3 -12 Manually Selecting T est Equipment - Network Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the Network radio button in the Connection T ype area.Result: A black dot appears in the circle.Continued68P09283A63 -5 3 -53FOA A UG 2007
T est Equipment Selection Chapter 3: LMF Oper ationProcedure 3 -12 Manually Selecting T est Equipment - Network Interface (Continued)4In the Ethernet T est equipment area click the checkbox(es) of the test equipmentbeing used.Result: Checkmarks appear in the box(es) clicked on.5If it is not already displayed, enter the IP address for the required piece test equipment inthe IP box in the Ethernet T est equipment area.6Click the Apply button. The button will darken until the selection is committed.7Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.Result: A checkmark appears in the box.8Click the Save button to save the selection configuration for future LMF sessions.9Click the Close button to close the LMF Options window .Automatically Selecting T est Equipment (Autodetection) – When using theautodetection feature to select test equipment, the LMF determines which test equipment itemsare actually communicating with the LMF .Procedure 3 -13 A utodetecting T est Equipment - Network Interface1In the LMF menu bar , select T ools >Options .Result: The LMF Options window appears.2Click on the T est Equipment tab (if not in the forefront).3Click the Network radio button in the Connection T ype area.Result: A black dot appears in the circle.4If it is not already displayed, enter the IP address for the required piece test equipment inthe IP box in the Ethernet T est equipment area.5Click the Detect button. The button will darken until the selection is committed.Result: F or each detected equipment item, a check will appear in its checkbox.6Click the Detect on startup checkbox in the Autodetection settings area to allow theLMF to detect the test equipment automatically on application startup.Result: A checkmark appears in the box.7Click the Save button to save the selection configuration for future LMF sessions.8Click the Close button to close the LMF Options window .3 -54 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Set Calibr ationTest Set Calibration■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Test Set Calibration BackgroundProper test equipment calibration ensures that the test equipment and associated test cables donot introduce measurement errors, and that measurements are correct.If the test equipment set being used to interface with the base station has beencalibrated and maintained as a set, this procedure does not need to be performed.(T est equipment set includes LMF computer , communications test set, additional testequipment, associated test cables, and adapters.)This procedure must be performedbeforebeginning the optimization. V erify all test equipment(including all associated test cables and adapters actually used to interface all test equipmentand the base station) has been calibrated and maintained as a set.If an y piece of test equipment, test cable, or RF adapter , that mak es up the calibr atedtest equipment set, has been replaced, re -calibr ation must be performed. F ailure todo so can introduce measurement errors, resulting in incorrect measurements anddegr adation to system performance.Calibration of the communications test set (or equivalent test equipment) mustbe performed at the site before calibrating the overall test set. Calibrate the testequipmentafterit has been allowed to warm -up and stabilize for aminimum of 60minutes.68P09283A63 -5 3 -55FOA A UG 2007
T est Set Calibr ation Chapter 3: LMF Oper ationCalibration Procedures IncludedAutomaticProcedures included in this section use the LMF automated calibration routines to determinepath losses of the supported communications analyzer , power meter , associated test cables,adapters, and (if used) antenna switch that make up the overall calibratedtest equipment set.A fter calibration, the gain/loss offset values are stored in a test measurement offset file onthe LMF computer .ManualAgilent E4406A T ransmitter T ester - The E4406A does not support the power levelzeroing calibration performed by the LMF . If this instrument is to be used for Bay Level Offsetcalibration and calibration is attempted with the LMF Calibrate T est Equipment function, theLMF will return a status window failure message stating that zeroing power is not supportedby the E4406A. Refer to Appendix D T est Equipment Preparation for instructions on usingthe instrument’s self -alignment (calibration) function prior to performing Bay Level Offsetcalibration.P ower Meters - Manual power meter calibration procedures to be performed prior toautomated calibration are included in Appendix D T est Equipment Preparation .Cable Calibration - Manual cable calibration procedures using the Advantest R3465communications system analyzer are provided in Appendix D T est Equipment Preparation ,if needed.PrerequisitesEnsure the following prerequisites have been met before proceeding:•T est equipment is correctly connected and turned on.•T est equipment addressing is set as required for the connection type being used (GPIB,Serial, Network)Calibrate Test Equipment Function (Except Agilent E4406A andAnritsu MT8212B)The Calibrate T est Equipment function zeros the power measurement level of the testequipment item to be used for TX calibration and audit. If both a power meter and an analyzerare connected, only the power meter is zeroed.3 -56 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Set Calibr ation1. The Agilent E4406A transmitter tester does not support power measurementlevel zeroing. Refer to the T est Equipment Calibration section of Appendix Ffor E4406A calibration.2. P ower measurement zeroing and other required calibration procedures for theAnritsuMT8212B are included in the Calibrating theAnritsuMT8212B on page3 - 57 subsection below .Prerequisites•T est equipment to be zeroed has been connected correctly for tests to be run.•T est equipment has been selected in the LMF ( T est Equipment Selection on page 3 - 48 )and detected.ProcedureP erform the following to calibrate the test equipment.Procedure 3 -14 Calibr ate T est Equipment - P ower Measurement Z eroing1From the Util menu, select Calibrate T est Equipment from the pull-down menu. ADirections window is displayed.2F ollow the directions provided.3Click on Continue to close the Directions window and start the calibration process. Astatus report window is displayed.4Click on OK to close the status report window .Calibrating the Anritsu MT8212BThree types of calibration are required for the MT812B. These are:•Zero out power meter•Calibrate TX Analyzer•Calibrate CW GeneratorProcedures for each type of calibration is covered in the following subsections.68P09283A63 -5 3 -57FOA A UG 2007
T est Set Calibr ation Chapter 3: LMF Oper ationZero Out Power MeterBefore using the MT8212B test set to perform RF power measurement, the test set internalpower meter function must be zeroed.Prerequisites – The following must be done before the zeroing out the power meter:•The test set is connected to the LMF computer serial port with theAnritsu800 -441 RS -232serial interface cable•T est equipment is turned on and has warmed up for at least 60 minutes.•T est equipment has been selected/detected in the LMF ( T est Equipment Selection onpage 3 - 48 )Zero out power meter – P erform the following to zero out the power meter function beforeperforming RF power measurements.Procedure 3 -15 Anritsu MT8212B Multi -function T est Set Z ero Out P ower Meter1In the LMF menu bar select Util >Calibrate T est Equipment .Result: ACalibrateAnritsuMT8212B window appears.2Click in the Option for zero out power meter onAnritsuMT8212B radio button inthe Zero Out P ower Meter area.Result: A black dot appears in the circle.3Click on OK .Result: ADirections window is displayed.4F ollow the directions provided.Result: A status report window will open.5Click on OK to close the status report window .Calibrate TX AnalyzerTX Analyzer calibration should be accomplished before performing any A TP operations withthe MT8212B.Prerequisites – The following must be done before the CW generator calibration:•The test set is connected to the LMF computer serial port with theAnritsu800 -441 RS -232serial interface cable•T est equipment has been selected/detected in the LMF ( T est Equipment Selection onpage 3 - 48 )•Additional items must be available for the TX Analyzer calibration method chosen asindicated in the following:3 -58 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Set Calibr ation•Standard Open -Short -Load Components calibration:Anritsu22N50 Open/Short, DC to 18 GHz, N(m) connector , 50 ohmAnritsuSM/PL precision load, DC -to -4 GHz, 42 dB, N(m) connector , 50 ohm•Standard InstaCal™ calibration:AnritsuICN50InstaCalcalibration module, 2 MHz to 4 GHz, N(m) connector , 50 ohmTX analyzer calibration – P erform the following to calibrate the MT8212B TX analyzerfunction..Procedure 3 -16 Anritsu MT8212B Multi -function T est Set TX Analyz er Calibr ation1In the LMF menu bar select Util >Calibrate T est Equipment .CalibrateAnritsuMT8212B window appears2Click in the radio button in the Calibrate TX Analyzer area.Result: A black dot appears in the circle.3Select the required frequency band from the dropdown list in the F requency Band: box.The dropdown list in the F requency Band: box is automatically populatedwith selections for the base station the LMF is logged into .4Enter the channel number to be calibrated in the Channel box.5Select the desired calibration method from the dropdown list in the Calibration Methodbox.6Click OK .Result: ADirections window is displayed.7F ollow the directions provided.8When actions required by directions have been completed, click on Continue to close theDirections window and start the generator calibration process.Result: A status report window is displayed.9Click on OK to close the status report window .Calibrate CW GeneratorBefore using the MT8212B test set to perform base station RS SI testing, the test set internalContinuous W ave (CW) generator must be calibrated.68P09283A63 -5 3 -59FOA A UG 2007
T est Set Calibr ation Chapter 3: LMF Oper ationPrerequisites - The following must be done before the CW generator calibration:•The test set is connected to the LMF computer serial port with theAnritsu800 -441 RS -232serial interface cable•T est equipment is turned on and has warmed up forat least 60 minutes.•T est equipment has been selected/detected in the LMF ( T est Equipment Selection onpage 3 - 48 )•RX cable(s) used in the calibration process must be calibrated for the channel for which theCW generator is to be calibrated (refer to Figure 3 -34 and Calibrating cables on page 3 - 65 )CW generator calibration - P erform the following to calibrate the MT8212B internal CWgenerator before performing RS SI testing with this test set.Procedure 3 -17 Anritsu MT8212B Multi -function T est Set CW Gener ator Calibr ation1In the LMF menu bar select Util >Calibrate T est Equipment .Result: CalibrateAnritsuMT8212B window appears2Click in the radio button in the Calibrate CW Generator area.Result: A black dot appears in the circle.3Select the required frequency band from the dropdown list in the F requency Band: box.The dropdown list in the F requency Band: box is automatically populatedwith selections for the base station the LMF is logged into .4Enter the channel or channels to be calibrated in the Channel(s) box (separate multiplechannels with a comma and no space).When two or more channels numbers are entered, the generator will becalibrated for each channel. Interpolation will be accomplished for otherchannels as required for TX calibration. Channels must be within the range ofthe selected frequency band.5Click OK .Result: ADirections window is displayed.6F ollow the directions provided.7When actions required by directions have been completed, click on Continue to close theDirections window and start the generator calibration process.Result: A status report window is displayed.3 -60 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP T est Set Calibr ationProcedure 3 -17 Anritsu MT8212B Multi -function T est Set CW Gener ator Calibr ation(Continued)8Click on OK to close the status report window .68P09283A63 -5 3 -61FOA A UG 2007
Setting and Editing Gener ator Calibr ation Data Chapter 3: LMF Oper ationSetting and Editing Generator Calibration Data■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Generator Calibration DataGenerator calibration data is automatically stored in a generator calibration data file by theLMF when the generator function of a test equipment item is calibrated using the LMF Util >Calibrate T est Equipment functions. Stored data values can be edited with this procedure,or new data can be entered manually for a test equipment item generator function which wascalibrated without using the LMF .This procedure MUST be used to enter calibr ation data v alues for an y MT8212B whichw as calibrated without using the LMF . F ailure to do this will gener ate incorrect resultsfor an y RS SI testing performed.PrerequisitesThe LMF is logged into a BTS .Set or Edit Generator Calibration DataP erform the following to enter new calibration data or edit existing data.Procedure 3 -18 Set or Edit Gener ator Calibr ation Data1In the LMF menu bar select Util >Edit >Generator Calibration Data .Result: Generator Calibration Data window appears with tabs for each type ofgenerator test equipment calibrated using the LMF (for example, theAnritsuMT8212B).2Click on the tab for the generator with data to be edited or entered.Result: The tab moves to the forefront.3T o edit existing values, click in the data field to be edited and make required changes.4T o add a new channel and its data:1. Click the Add Row button.2. Click in the field where data is to be entered; for example, F requency Band ,Channel # , or P ower (dB) .3. Enter the desired value.Continued3 -62 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Setting and Editing Gener ator Calibr ation DataProcedure 3 -18 Set or Edit Gener ator Calibr ation Data (Continued)F or F requency Band fields, select the required frequency band from thedropdown provided. Selections are made available for the BTS which the LMFis logged into .5T o delete a row , click in the row , and then click the Delete Row button.6F or each tab with changes, click the Save button to save the displayed values.•V alues entered after the Save button was used will not be saved.•If generator calibration values exist for two different channels assigned toone frequency band, the LMF will interpolate for all other channels onthis frequency band.•Entered values will be used by the LMF as soon as they are saved. It is notnecessary to log out and log back into the LMF for changes to take effect.68P09283A63 -5 3 -63FOA A UG 2007
Cable Calibr ation Chapter 3: LMF Oper ationCable Calibration■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Calibrating Cables OverviewThe cable calibration function measures the loss (in dB) for the TX and RX cables that are to beused for testing. A CDMA analyzer is used to measure the loss of each cable configuration (TXcable configuration and RX cable configuration). The cable calibration consists of the following:•Measuring the loss of a short cable – This is required to compensate for anymeasurement error of the analyzer . The short cable (used only for the calibration process)is used in series with both the TX and RX cable configuration when measuring. Themeasured loss of the short cable is deducted from the measured loss of the TX and RXcable configuration to determine the actual loss of the TX and RX cable configurations.The result is then adjusted out of both the TX and RX measurements to compensate forthe measured loss.•Measuring the short cable plus the RX cable configuration loss – The RX cableconfiguration normally consists only of a coax cable with type -N connectors that is longenough to reach from the BTS RX port of the test equipment. Refer to Figure 3 -31 ,Figure 3 -32 ,Figure 3 -33 , or Figure 3 -34 for specific cable and connection requirements foreach type of communications system analyzer .•Measuring the short cable plus the TX cable configuration loss – The TX cableconfiguration normally consists of two coax cables with type N connectors and a directionalcoupler , a load, and an additional attenuator (if required by the specified BTS). The totalloss of the path loss of the TX cable configuration must be as required for the BTS (normally30 or 50 dB). Refer to Figure 3 -31 ,Figure 3 -32 ,Figure 3 -33 , or Figure 3 -34 for specificcable and connection requirements for each type of communications system analyzer .Cable Calibration Set–up DiagramsFigure 3 -31 and Figure 3 -32 show the cable calibration set–up for various supported test sets.The left side of the diagram depicts the location of the input and output connectors of each testequipment item, and the right side details the set up for each test.Calibrate Test Cabling using Communications System AnalyzerCable Calibration is used to calibrate both TX and RX test cables.3 -64 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Cable Calibr ationPrerequisitesEnsure the following prerequisites have been met before proceeding:•One of the following:LMF computer serial port and test equipment are connected to the GPIB boxF or MT8212B, the test equipment is connected to the LMF computer serial portF or E7495A/B, the LMF computer NIC and the E7495 are connected to the Ethernethub (T est Equipment Connectionsection)•T est equipment is turned on and has warmed up for at least 60 minutes.•T est equipment has been selected/detected in the LMF (Refer to theSelection Proceduressubsection of theT est Equipment Selectionsection)Calibrating cablesRefer to Figure 3 -31 ,Figure 3 -32 ,Figure 3 -33 , or Figure 3 -34 and perform the following tocalibrate the test cable configurations.Procedure 3 -19 A utomatic Cable Calibr ation1From the Util menu, select Cable Calibration .Result: ACable Calibration window is displayed.2Enter the channel number(s) in the Channels box.Multiple channel numbers must be separated with a comma and no space (forexample; 200,800). When two or more channel numbers are entered, the cablesare calibrated for each channel. Interpolation is accomplished for other channelsas required for TX calibration.3In the Cable Calibration pick list select one of the following:•TX and RX Cable Cal•TX Cable Cal•RX Cable Cal4Click OK and follow the direction displayed for each step. A status report window displaysthe results of the cable calibration.68P09283A63 -5 3 -65FOA A UG 2007
Cable Calibr ation Chapter 3: LMF Oper ationFigure 3 -31 Cable Calibr ation T est Setup – Agilent 8935ti-cdma-06176.epsHEWLETT-P ACKARD MODEL HP 8935DUPLEXOUTANTINSUPPORTED TEST SETS100-W ATT  (MIN)NON-RADIA TINGRF LOADTESTSETA. SHORT CABLE CALSHORTCABLEB. RX TEST SETUPTESTSETC. TX TEST SETUPCALIBRATION SET UPN-N FEMALEADAPTERRXCABLETXCABLESHORTCABLETESTSETRXCABLESHORTCABLEN-N FEMALEADAPTERDIRECTIONAL COUPLER(30 DB)50Ω TERM.10 DB MINIMUMIN-LINE  ATTENUATORTX CABLE FORDRDC TX TESTCABLE CALIBRATION3 -66 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Cable Calibr ationFigure 3 -32 Cable Calibr ation T est Setup – Adv antest R3267/R3562,E4406A/E4432B ,and Agilent E4432/8935 Series E6380Ati-cdma-06177.epsSUPPORTED TEST SETS100-W ATT (MIN)NON-RADIA TINGRF LOADTESTSETA. SHORT CABLE CALSHORTCABLEB. RX TEST SETUPTESTSETC. TX TEST SETUPCALIBRATION SET UPN-N  FEMALEADAPTERRXCABLETXCABLESHORTCABLETESTSETRXCABLESHORTCABLEN-N FEMALEADAPTERRF INRF OUTADVANTEST R3267 (TOP) AND R3562 (BOTTOM)EXT TRIG INMOD TIME BASE IN(EXT REF IN)RFINPUT 50OHMRFOUTPUT50 OHMAGILENT E4432B (TOP) AND E4406A (BOTTOM)50 Ω TERM.10 DB MINIMUMIN-LINE  ATTENUATORDIRECTIONAL COUPLER(30 DB)AGILENT E4432B (TOP) AND 8935 SERIESE6380A (BOTTOM)RFOUTPUT50 ΩANTINNOTE:10 MHZ IN on rear of signal generator is connected to 10 MHZ REF OUT on side of CDMA Base Station Test SetTX CABLE FORDUPLEXED TX/RXTEST CABLECALIBRATIONNOTE:SYNTHE REF IN on rear signal generator isconnected to 10 MHZ OUT on rear of spectrumanalyzer68P09283A63 -5 3 -67FOA A UG 2007
Cable Calibr ation Chapter 3: LMF Oper ationFigure 3 -33 Cable Calibr ation T est Setup – Agilent E7495A and E7495Bti-cdma-06178.epsTESTSETA. SHORT CABLE CALSHORTCABLECALIBRATION SET UP100-W ATT  (MIN)NON-RADIA TINGRF LOADB. RX and TX TEST SETUP10 DB MIMIMUMIN-LINE  ATTENUATORN-N FEMALEADAPTERTXCABLEDIRECTIONALCOUPLER(30 DB)50 ΩTERM.10 DB PAD10 DB PADSHORTCABLE10 DB PAD10 DB PADTESTSETSUPPORTED TEST SETSAGILENT  E7495A OR E7495BPORT 1RF OUTPORT 2RF INUse onlyAgilent suppliedpower adapterGPSGPIOSerial 1Serial 2Power REF50 MHzSensorExt RefInEven SecondSync InAntennaPort 1RF Out / SWRPort 2RF InRXCABLENOTES:1. FOR RX TESTING, TOTAL RF PATHATTENUATION(CABLES+COUPLERS+ATTENUATORS)MUST BE WITHIN THE VALUESSPECIFIED BELOW FOR EACH TYPEOF TEST SET:E7495A: 25 TO 32 dBE7495B: 10 TO 100 dB2. WHEN USING THE E7495A, TXTESTS REQUIRE A MINIMUM OF 30 DBATTENUATION PLUS THE CABLELOSSES.TX CABLE FORDUPLEXED TX/RXTEST CABLECALIBRATION3 -68 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Cable Calibr ationFigure 3 -34 Cable Calibr ation T est Setup – Anritsu MT8212BSUPPORTED TEST SETS100-W ATT (MIN.)NON-RADIA TINGRF LOADTESTSETA. SHORT CABLE CALSHORTCABLETESTSETC. RX and TX TEST SETUPCALIBRATION SET UPN-N  FEMALEADAPTERSHORTCABLE50Ω TERM.TX TESTS: 10 DB MINIMUMIN-LINE  ATTENUATORRX TEST: 35 DB MINIMUMIN-LINE  ATTENUATORDIRECTIONAL COUPLER(30 DB)RF IN50ΩRF OUT50ΩANRITSU MT8212BTX AND RXCABLETX AND RXCABLENOTE: FOR RX TESTING (RSSI), TOTALRF PATH ATTENUATION(CABLES+COUPLERS+ATTENUATORS)MUST BE 65 dB OR GREATER.ti-cdma-06208.epsCalibrate Test Cabling Using Signal Generator & SpectrumAnalyzerManual cable calibration can be performed by following Procedure 3 -20 to calibrate theTX/duplexedRX cables using a signal generator and spectrum analyzer . Refer to Figure 3 -35 ,if required. F ollow Procedure 3 -21 to calibrate thenon–duplexed RX cables using the signalgenerator and spectrum analyzer . Refer to Figure 3 -36 , if required.68P09283A63 -5 3 -69FOA A UG 2007
Cable Calibr ation Chapter 3: LMF Oper ationTX and Duplexed RX Cable CalibrationProcedure 3 -20 Calibr ating TX and Duplex ed RX Cables Using Signal Gener ator and SpectrumAnalyz er1Connect a short test cable between the spectrum analyzer and the signal generator .2Set signal generator to 0 dBm at the customer frequency .3Use a spectrum analyzer to measure signal generator output (see Figure 3-35 A) and recordthe value.4Connect the spectrum analyzer’s short cable to Figure 3-35 point B, (as shown in the lowerright portion of the diagram) to measure cable output at customer frequency . Record thevalue at point B,5Calibration factor = A - B. Example: Cal = -1 dBm - (-53.5 dBm) = 52.5 dBThe short cable is used for calibration only . It is part of the final test setup. A ftercalibration is completed, rearrange any cables. Use the equipment setup, as is, toensure test procedures use the correct calibration factor .Figure 3 -35 TX and Duplex ed RX Cable Calibr ation50 OHM TERMINATION30 DBDIRECTIONALCOUPLERSPECTRUM ANALYZERA40W NON-RADIATING RF LOADBSHORT TEST CABLETHIS WILL BE THE TX TEST CABLE CONNECTION TO THE POWER SENSOR OR COMMUNICATIONS TEST SET INPUTIPORT DURING TX CALIBRATION AND ATP TESTS.SHORT TEST CABLECABLE FROM 10 DB MINIMUM @ 20W ATTENUATORTO THE POWER SENSOR OR COMMUNICATIONTEST SET.10DB MINIMUM, 20 WIN-LINE ATTENUATORSPECTRUM ANALYZERSIGNALGENERATORSIGNALGENERATORti-cdma-00145.eps3 -70 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Cable Calibr ationNon–duplexed RX Cable CalibrationProcedure 3 -21 Calibr ating RX Cables Using a Signal Gener ator and SpectrumAnalyz er1Connect a short test cable to the spectrum analyzer and connect the other end to the SignalGenerator .2Set signal generator to -10 dBm at the customer’s RX frequency .3Use spectrum analyzer to measure signal generator output (see Figure 3-36 ,A) and recordthe value for A.4Connect the test setup, as shown in the lower portion of the diagram to measure the output atthe customer’s RX frequency . Record the value at Figure 3-36 , point B.5Calibration factor = A - B.Example:Cal = -12 dBm - (-14 dBm) = 2 dBm6The short cable is used forcalibration only. It isnotpart of the final test setup.A fter calibration is completed,do notrearrange any cables. Use the equipmentsetup as is to ensure test procedures use the correct calibration factor .68P09283A63 -5 3 -71FOA A UG 2007
Cable Calibr ation Chapter 3: LMF Oper ationFigure 3 -36 Non -Duplex RX Cable Calibr ationti-cdma-06209.epsSPECTRUMANALYZERSIGNALGENERATORABSPECTRUMANALYZERSHORTTESTCABLESHORT TESTCABLECONNECTION TO THE COMMUNICATIONTEST SET OUTPUT PORTDURING RX MEASUREMENTS.SIGNALGENERATORBULLETCONNECTORCONNECTION TO THE RX PORTSDURING RX MEASUREMENTS.LONGCABLE 2Setting Cable Loss ValuesCable loss values for the TX and RX test cable configurations are normally set by accomplishingcable calibration using the applicable test equipment. The resulting values are stored in thecable loss files. The cable loss values can also be set/changed manually .If cable calibr ation w as performed without using the LMF , cable loss v alues must bemanually entered in the LMF database. F ailure to do this will result in inaccur ate UBScalibr ation and reduced site performance.PrerequisitesLMF is logged into the UBS3 -72 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Cable Calibr ationProcedureP erform the following to set cable loss values.Procedure 3 -22 Setting Cable Loss V alues1In the LMF menu bar , click on Util >Edit >Cable Loss2In the data entry pop–up window , selectoneof the following:•TX Cable Loss•RX Cable Loss3T o add a new channel number , click on Add Row , and click in Channel# and Loss (dBm)columns and enter the desired values.4T o edit existing values, click in the data box to be changed and change the value.5T o delete a row , click on the row and then click on the Delete Row button.6T o save displayed values, click on the Save button.7T o exit the window , click on the Dismiss button.V alues entered/changed after the Save button was used are not saved.•If cable loss values exist for two different channels, the LMF will interpolatefor all other channels.•Entered values are used by the LMF as soon as they are saved. Logging outand logging in again is not necessary .68P09283A63 -5 3 -73A UG 2007 FOA
Cable Calibr ation Chapter 3: LMF Oper ation3 -74 68P09283A63 -5FOA A UG 2007
C h a p t e r4Acceptance Test Procedures■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■68P09283A63 -5 4 -1A UG 2007 FOA
Introduction to A TP Chapter 4: Acceptance T est ProceduresIntroduction to ATP■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■IntroductionGeneralThe Acceptance T est Procedures (A TP) allow Cellular Field Engineers (CFEs) to run automatedacceptance tests on all UBS subsystem devices equipped in the NEC using the LMF and thetest equipment it supports.LMF User InterfaceThis chapter provides procedures for performing acceptance testing from the LMF GraphicalUser Interface (GUI) environment, the recommended method. The GUI provides the advantagesof simplifying the LMF user interface, reducing the potential for mis -keying commands andassociated parameters, and speeding up the execution of complex operations involving multiplecommand strings. If it is believed the LMF command line interface (CLI) will provide additionalinsight into A TP operation or unexpected test results, refer to LMF CLI Reference.Test ReportsThe CFE can choose to save the results of A TP tests to a report file from which A TP reports aregenerated for later printing. See the Generating an A TP Report section in this chapter .Test Equipment SelectionBecause test equipment functions during acceptance testing are controlled by the LMF directly ,only the test equipment models supported by the LMF can be used.1. Before using the LMF , read the Dev eloper R elease Notes for WinLMF section inthe LMF Help function on -line documentation for an y applicable information. P a yparticular attention to the Ca v eats/Known Issues part of this appendix.2. The A TP test is to be performed on out -of -service sectors only .3. DO NO T substitute test equipment with other models not supported b y the LMF .4 -2 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Introduction to A TPTest Equipment Set CalibrationRefer to T est Set Calibration on page 3 - 55 ,Cable Calibration on page 3 - 64 , and Appendix DT est Equipment Preparation for detailed interconnection information needed for calibratingequipment, cables, and other test equipment set components.Equipment has been factory -tested for FCC compliance. If license -governing bodiesrequire documentation supporting UBS site compliance with regulations, a full A TPmay be necessary . P erform the Reduced A TP only if reports for the specific UBSsite are NOT required.A fter verifying that the proper operational software was code synced to the UBS , the CFE mustperform these procedures (minimal recommendation):1. V erify the TX/RX paths by performing TX Audit and Receive Signal Strength Indicator(RS SI) tests.2. Be sure calibration data for all equipped sector -carriers is obtained and loaded on theOMC -R for normal site operation.Should failures occur while performing the specified tests, refer to the Basic Troubleshootingsection of this manual for help in determining the failure point. Once the point of failure hasbeen identified and corrected, refer to the FRU Optimization and A TP T est Matrix in Appendix BFRU Optimization/A TP Matrix to determine the applicable test that must be performed.In the unlikely event that the UBS passes these tests but has a forward link problem duringnormal operation, the CFE should then perform the additional TX tests for troubleshooting: TXspectral mask, TX rho, and TX code domain.1x EV -DO ATPShould the UBS Macro be equipped with EV -DO cards/modules, refer to1x EV -DO SystemA TP — 68P09283A59for testing procedures.68P09283A63 -5 4 -3FOA A UG 2007
Acceptance T est Procedures - TX & RX Chapter 4: Acceptance T est ProceduresAcceptance Test Procedures - TX & RX■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Reduced and Full ATPThe full A TP (all the A TP tests) is optional. It is recommended that the reduced A TP be used.The reduced A TP consists of TX Audit and Receive Signal Strength Indicator (RS SI).TX Audit and RSSI TestsTX Audit The Audit is a power out test that will pass within +/ -2 dB of the expected power .The standard pattern per S -C is 43dBm and the Audit test will pass if the output power iswithin the limits listed above.TX Audit T est Procedure P erform the procedure in Procedure 4 -1 for TX Audit.Procedure 4 -1 Procedure for TX A udit1Set up test equipment for TX acceptance tests per Figure 3-23 throughFigure 3-262If it has not already been done, configure the test equipment for TX pathaudit as in Figure 3-233Click on the devices to be tested.4Click T ests > TX > TX Audit5Select the appropriate carrier in the Channels/Carrier pick list.Enter the channel number in the Carrier # Channels box.T o select multiple items, hold down the Shift or CTRL key whilemaking the selections.6Click OK . The status report window is displayed and then a Directionspop-up is displayed.7F ollow the cable connection directions as they are displayed. T est results aredisplayed in the status report window .Continued4 -4 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Acceptance T est Procedures - TX & RXProcedure 4 -1 Procedure for TX A udit (Continued)8Click Save Results or Dismiss button.If Dismiss is selected, the test results will not be saved.Figure 4 -1 TX A udit Signalti-cdma-TX_Audit.eps68P09283A63 -5 4 -5FOA A UG 2007
Acceptance T est Procedures - TX & RX Chapter 4: Acceptance T est ProceduresReceive Signal Strength Indication Acceptance TestOverview This test verifies Receive Signal Strength Indication (RS SI) for the selected sectorsto ensure integrity of the reverse (RX) path, that path losses are within tolerances required forcorrect receiver operation, and correct installation of the RX path. T esting is performed usingthe calibrated external test equipment as the signal source. The test equipment is controlled bythe LMF during the test. The receive signal generated by the test equipment is injected into thesector RX path to be tested at the applicable UBS main and / or diversity receive ports.Equipment Operation During T esting The LMF sets the pilot channel power level of thesector for the selected sector to +XX dBm (measured at the TX port of the frame) and enablesthe sector -carrier on pilot channel only to enable the RX circuitry . The LMF then commands thetest equipment to generate the receive signal on the selected carrier at -80 dBm as measuredat the UBS RX portT est Measurements The power level of the received signal is measured by the RFX. TheLMF corrects the measured power of the signal using the RX BLO and determines if thecorrected signal gain is equal to or greater than the following specified criteria for the band inwhich the UBS operates:•1900 MHz: –80 dBm ( -86 dBm or greater)•800 MHz: –80 dBm ( -86 dBm or greater)The LMF provides -80 dBm signal (default) input to the UBS . The RS SI must be+/ -6 dB.Receive Signal Strength Indicator ATPP erform the following procedure for RS SI acceptance testing.Procedure 4 -2 Procedure for RS SI Acceptance T esting1Set up the test equipment for RX acceptance tests. Reference Figure 3-23through Figure 3-26 .2Select the carrier to be tested.3In the LMF window menu bar , click on T ests > RX > RS SI4Select the carrier to be tested in the Channels/Carriers pick list which isdisplayed.Continued4 -6 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Acceptance T est Procedures - TX & RXProcedure 4 -2 Procedure for RS SI Acceptance T esting (Continued)5Select the RX Branch to be tested from the choices in the drop down listprovided (Both, Main, Diversity)6Enter the appropriate power level into the Generator amplitude box (default:-80 dBm)7Click OK . A status bar will be displayed followed by a Directions pop upwindow .8F ollow cable connection directions as they are displayed, and click theContinue button to begin testing. Progress will be indicated in the status bar .9When the test is completed, click Save Results or Dismiss button, asrequired, in the Status Report window .If Dismiss is selected, then the test results will not be saved.Automated ATPThis section covers the general requirements and procedures for conducting both automatedA TP testing and performing individual A TP tests.Automated ATP Test OptionsAcceptance tests can be run individually or as one of the following automated groups:•All TX: TX tests verify the performance of the UBS transmit line up.•All RX: RX tests verify the performance of the UBS receiver line up.•All TX/RX: Executes all the TX and RX tests.•Full Optimization: Executes the TX calibration, downloads the BLO , and executes the TXaudit before running all of the TX and RX tests.The Full Optimization test can be run if TX path calibration is needed before the TXand RX acceptance tests are run.The STOP button can be used to stop the testing process.The LMF is optimized to perform the tests as quickly as possible when selecting the“perform all" menu options. It is recommended that the user select this option on aper sector/carrier option where possible to save time.68P09283A63 -5 4 -7FOA A UG 2007
Acceptance T est Procedures - TX & RX Chapter 4: Acceptance T est ProceduresRequired Test EquipmentThe following test equipment is required:•LMF•P ower Meter•Communications System Analyzer•Before connecting an y test equipment directly to an y UBS TX OUT connector ,verify that there are no CDMA channels keyed .•A t activ e sites, ha v e the OMC -R oper ator place the carrier assigned to the UBSunder test OOS . F ailure to do so can result in serious personal injury and/orequipment damage.T est equipment must be calibrated and the cables re -calibrated before using them toperform acceptance tests.ATP Test PrerequisitesBefore attempting to run any A TP tests, ensure the following have been completed:•LMF is logged into the UBS .•All FRUs on the LMF screen are INS (Green)•T est cables are calibrated•T est equipment is connected for A TP tests (refer to A TP T est Setup illustrations in the T estEquipment Set Up section of Appendix E Optimization and Calibration Procedures )•T est equipment has been selected in the LMF , warmed up 60 minutes and calibrated•All required Ethernet test equipment connections are made•UBS transmit connectors are terminated with either non -radiating loads or connected tothe test equipment as specified in Figure 3 -27 through Figure 3 -30 .4 -8 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Acceptance T est Procedures - TX & RXBefore a FER test is run, be sure that the following is done:All tr ansmitter connectors are properly terminated. T erminations should be 50 -Ohms,200 W . F ailure to observ e these w arnings ma y result in bodily injury or equipmentdamage.Procedure 4 -3 Setup T est Equipment — TX Output V erif y/Control T ests1If it has not already been done, interface the LMF computer to the UBS .2If it has not already been done, refer to Procedure 3-3 to start a GUI LMFsession and log into the UBS .3If it has not already been done, refer to Figure 3-23 ,Figure 3-24 ,Figure 3-25 ,or Figure 3-26 as applicable, for the test equipment and antennas being used,to connect test equipment for acceptance testing.LMF -based measurements factor in TX cable loss between the UBSand the test equipment.Antenna ConnectorsAll acceptance testing requires test equipment connections to the UBS antenna TX or RXconnectors. Refer to the A TP T est Setup illustrations in the T est Equipment Set Up section ofAppendix E Optimization and Calibration Procedures for specific connection requirementsRecommended TestsThe recommended tests are TX Audit and Receive Signal Strength Indicator (RS SI) to confirmthe physical assembly of the frame and that all the cables TX, RX, Digital etc are correctlyconnected. The rest of the tests are supported, optional, or for troubleshooting purposes.TX/RX ATP Test ProcedureF ollow the procedure in Procedure 4 -4 to perform the All TX/RX A TP test.Procedure 4 -4 All TX/RX A TP T est ProcedureContinued68P09283A63 -5 4 -9FOA A UG 2007
Acceptance T est Procedures - TX & RX Chapter 4: Acceptance T est Procedures1Set up the test equipment for abbreviated tests per Procedure 4-32Select the device(s) to be tested.T o select multiple items, hold down the Shift or Ctrl key whilemaking the selections.F or all TX tests except Code domain, a SectorCarrier must beselected. F or code domain select the modem and carrier . F or RXtest — FER select the modem and SectorCarrier . F or RX test —RS SI select SectorCarrier only .3Click on T ests in the UBS Menu bar , and select All TX/RX A TP ... frompull-down menu.4Select the appropriate SectorCarrier (carrier-bts#-sector#-carrier#)displayed in the Channels/Carrier pick list.Since the UBS supports OMNI configurations only , sector# willalways be 1.5V erify that the correct channel number for the selectedSectorCarrier is shown in the Carrier # Channels box.If not obtain the latest bts-#.necf files.If necessary , the correct number may be manually entered intothe Carrier # Channels box.6Select the appropriate RX Branch (Both,Main, or Diversity ) from the drop-down menu.In the R ate Set box, select the appropriate data rate (1=9600, 2= 14400, 3 =9600 1X) from the drop-down list.7In the T est P attern box, select the Standard test pattern from the dropdown list in the Bay Level Offset Calibration section.8Click on the OK button.The status report window and a Directions pop-up are displayed.9F ollow the cable connection directions as they are displayed.The test results are displayed in the status report window .Continued4 -10 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Acceptance T est Procedures - TX & RXProcedure 4 -4 All TX/RX A TP T est Procedure (Continued)10Click on Save Results or Dismiss .If Dismiss is used, the test results will not be saved in the testreport file.Figure 4 -2 TX T est Options Screenenter_filena me_her e_and_mo ve_per_st ep_8P erform the procedure in Procedure 4 -5 for all -inclusive transmit test.Procedure 4 -5 All TX A TP T est1Set up the test equipment for TX acceptance tests per Procedure 4-3Continued68P09283A63 -5 4 -11FOA A UG 2007
Acceptance T est Procedures - TX & RX Chapter 4: Acceptance T est ProceduresProcedure 4 -5 All TX A TP T est (Continued)2On LMF , select devices to be tested.T o select multiple items, hold down the Shift or Ctrl key whilemaking the selections.3Click on T ests in the BTS Menu bar , and select All TX A TP ... from pull-downmenu.4Select the appropriate carrier (HDModem) from those displayed in theChannels/Carrier pick list.5V erify that the correct channel number for the selectedcarrier is shown in the Carrier # Channels box.If not obtain the latest bts-#.necf files.If necessary , the correct number may be manually entered intothe Carrier # Channels box.6In the T est P attern box, select the Standard test pattern from the dropdown list in the Bay Level Offset Calibration section. Other selections areavailable for TX Mask only .7Click OK to display a status bar followed by a Directions pop-up window .8F ollow the cable connection directions as they aredisplayed, and click the Continue button to begin testing.As the A TP process is completed, results will be displayed in a status reportwindow .9Click the Save Results or Dismiss button.If Dismiss is used, the test results will not be saved in the testreport file.4 -12 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Acceptance T est Procedures - TX & RXP erform the procedure in Procedure 4 -6 for all -inclusive RX test.Procedure 4 -6 All RX A TP T est1Set up the test equipment for abbreviated acceptance tests per Procedure 4-32On LMF , select devices to be tested.T o select multiple items, hold down the Shift or Ctrl key whilemaking the selections.3Click on T ests in the UBS Menu bar , and select All RX T est... from pull-downmenu.4Select the appropriate carrier from those displayed in the Channels/Carrierpick list.5Select the appropriate RX Branch (Both,Main, or Diversity ) from the drop-down menu.In the R ate Set box, select the appropriate data rate (1=9600, 2= 14400, 3 =9600 1X) from the drop-down list.6Click OK to display a status bar followed by a Directions pop-up window .7F ollow the cable connection directions as they aredisplayed, and click the Continue button to begin testing.As the A TP process is completed, results will be displayed in a status reportwindow .8Click the Save Results or Dismiss button.If Dismiss is used, the test results will not be saved in the testreport file.68P09283A63 -5 4 -13FOA A UG 2007
Individual T ests Chapter 4: Acceptance T est ProceduresIndividual Tests■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■TX and RX TestingThe following individual A TP tests can be used to evaluate specific aspects of UBS operationagainst individual performance requirements. All testing is performed using the LMF GUIenvironment.TX TestingTX tests verify transmit antenna paths and output power control. All tests are performed usingthe external, calibrated test equipment. All measurements are made at the appropriate UBSTX OUT connector(s).TX tests verify TX operation of the entire CDMA forward link using selected sector -carriersassigned to respective sector antennas. Each sector -carrier is keyed up to generate a CDMAcarrier (using BLO) at the NEC file -specified carrier output power level.RX TestingRX testing verifies receive antenna paths for the sector -carriers selected for the test. All testsare performed using the external, calibrated test equipment to inject a CDMA RF carrier withall zero long code at the specified RX frequency at the appropriate UBS RX IN connector(s).RX tests verify RX operation of the entire CDMA reverse link.Individual TestsStandard P attern (per the 3GPP2 standard) - F or UBS Macro, the standard pattern isthe total digital gain of the signal (383) that includes the following channels (9 in all) andtheir individual digital gain:•Pilot -171•P age - 165•Sync - 83•6xTCH - 117In the UBS Macro, the pilot is set to 36dBm, which brings the total power of this pattern to43dBm - 7dB higher .Spectral Purity TX MaskThis test verifies that the transmitted CDMA carrier waveform generated on each sector meetsthe transmit spectral mask specification with respect to the assigned NEC file values.4 -14 68P09283A63 -5FOA A UG 2007
1X UBS Macro B T S Optimization/A TP Individual T estsWaveform Quality (Rho)This test verifies the transmitted Pilot channel element digital waveform quality of eachsector -carrier enabled at a specific frequency per the current NEC file assignment. All testsare performed using the external calibrated test set controlled by the same command. Allmeasurements are via the appropriate TX OUT connector .Pilot Time OffsetThe Pilot Time Offset is the difference between the CDMA analyzer measurement interval (basedon the UBS system time reference) and the incoming block of transmitted data from the UBS .Code Domain Power/Noise FloorThis test verifies the Code Domain P ower/Noise of each sector -carrier is enabled at a specificfrequency per the current NEC file assignment. All tests are performed using the externalcalibrated test set controlled by the same command. All measurements are via the appropriateTX OUT connector .Frame Error Rate (FER)The Frame Error R ate (FER) test verifies RX operation of the entire CDMA Reverse Linkusing all equipped DMIs assigned to all respective sectors/antennas. This test verifies theUBS sensitivity on all traffic channel elements currently configured on all equipped DMIs atan RF input level of -123.0 dBm.TX AuditThe TX Audit is a power out test that will pass within +/ -2dB of the expected power . Thestandard power per S -C is 43dBm and the Audit test will pass, if the output power is within thelimits listed above.CalibrationIt is optional, but supported. The calibration in UBS is always a negative number representingthe LOS S between the output of the XMI to the top of the frame. In this frame, it is typically-1dB to –2dB depending on RF elements in the frame.68P09283A63 -5 4 -15FOA A UG 2007