Nokia of America BBTRX-05 PCS Wireless Base Station Transceiver User Manual RRH PCS UserMan exh3
Alcatel-Lucent USA Inc. PCS Wireless Base Station Transceiver RRH PCS UserMan exh3
USERS MANUAL
APPLICANT: Alcatel-Lucent EXHIBIT 3 FCC ID: AS5BBTRX-05 EXHIBIT 3 Section 2.1033 (c)(3) INSTALLATION AND OPERATING INSTRUCTIONS A copy of the installation and operating instructions to be furnished to the user. A draft copy of the instructions may be submitted if the actual document is not available. The actual document shall be furnished to the FCC when it becomes available. Response A copy of the “Alcatel-Lucent 9927 Distributed Base Station Outdoor Site Preparation Guidelines” manual is attached to this exhibit. Page 1 of 1 Use pursuant to applicable agreements Title page Alcatel-Lucent 9927 Distributed Base Station Outdoor Site Preparation Guidelines 401-703-516 Issue 1 | March 2012 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements Use pursuant to applicable agreements Legal notice Legal notice Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2012 Alcatel-Lucent. All rights reserved. Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization. Not to be used or disclosed except in accordance with applicable agreements. Notice Every effort was made to ensure that the information in this Information Product (IP) was complete and accurate at the time of printing. However, information is subject to change. Ordering information The ordering number for this document is 401-703-516. To order this or other Alcatel-Lucent information products, see “To obtain documentation, training, and technical support or submit feedback” on the Flexent ®/AUTOPLEX ® Wireless Networks System Documentation CD-ROM, 401-010-001 or the documentation web site at (https://wireless.support.lucent.com/amps/rls_info/rls_doc/cd_docs/customer.support/customer.support_toc.pdf.wen). Technical support For technical support, see “To obtain documentation, training, and technical support or submit feedback” on the Flexent ®/AUTOPLEX ® Wireless Networks System Documentation CD-ROM, 401-010-001 or the documentation web site at ( (https://wireless.support.lucent.com/amps/rls_info/rls_doc/cd_docs/ customer.support/customer.support_toc.pdf.wen). Alcatel-Lucent – Proprietary Use pursuant to applicable agreements About this document About this document Purpose This Information Product (IP) describes the basic site requirements that should be used to plan a Alcatel-Lucent 9927 Distributed Base Station outdoor site. This document includes specific tasks that should be completed at the job site before an installation can begin. Reason for reissue This document is Alcatel-Lucent 9927 Distributed Base Station Outdoor Site Preparation Guidelines, document number 401-703-516, Issue 1. This issue incorporates information available as of December 2011. This is the second issue of this document. Whenever this document is reissued, the reasons for reissue will be provided in this section. The reasons for reissue are shown in the table below. Issue Reason Intended audience This IP is intended for customers preparing a 9927 Distributed Base Station outdoor site. Conventions used The following conventions are used in this IP: Measurements All measurements are shown in metric form, and are followed by the English conversion in parentheses. ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary xi 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 About this document .................................................................................................................................................................................................................................... Naming conventions In this IP, the Alcatel-Lucent 9927 Distributed Base Station Outdoor Cabinet is referred to as 9927 Distributed Base Station Outdoor Cabinet. Standard cross-sections and wire diameters of round copper conductors The following table is from CEI/IEC 60947-1:2004, Table 1, Standard cross-sections of round copper conductors and approximate relationship between mm 2 and AWG/kcmil sizes for reference. Additional wire sizes are included in this information product as appropriate for the topic. ISO rated cross-sectional area (mm2) AWG/kcmil size 0.2 24 0.34 22 0.5 20 0.75 18 1.5 16 2.5 14 12 10 10 16 25 35 50 0 (1/0) 70 00 (2/0) 95 000 (3/0) 0000 (4/0) 120 250 kcmil 150 300 kcmil 185 350 kcmil 400 kcmil 240 500 kcmil 300 600 kcmil .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor xii Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 About this document .................................................................................................................................................................................................................................... ISO rated cross-sectional area (mm2) AWG/kcmil size NOTE: The dash, when it appears, counts as a size when considering connecting capacity (see 7.1.7.2 in the standard). Related documentation Base station planners and site preparation personnel must have the appropriate reference material, and all applicable local, regional and national code documentation. Alcatel-Lucent documents (required, or required as applicable) • • • • • • Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115 Installation Instructions, Interface Kit for Attachment of 60ECv2 Battery Cabinet to Outdoor 9927 Base Station Primary Cabinet with Integrated Power, 109621573 Installation Instructions, Interface Kit for Non-Standard Attachment of 60ECv2 Battery Cabinet to Outdoor 9927 Base Station Primary Cabinet with Integrated Power, 109676239 Installation Instructions, Interface Kit for Installation of Second 60ECv2 Battery Cabinet with First 60ECv2 Battery Cabinet, 109683177 Engineering Rules for Flexent ® Modular Cell 4.0B, ER_0102_0004 Engineering Rules for Factory and Field Installation Kits for 9927 Distributed Base Station, ER_0105_0006 Other documents (required) • • • • Standard for Installation of Lightning Protection Systems, NFPA 780 Recommended Practices on Surge Voltages in Low Voltage AC Power Circuits, IEEE C62.41 (Latest Edition) GR-487-CORE, Telcordia GR-63-CORE, Telcordia Alcatel-Lucent documents (not required) The following documents are related but not required for a 9927 Distributed Base Station Outdoor Cabinet outdoor site. • • • Alcatel-Lucent 9927 Distributed Base Station System Description, 401-703-729 Alcatel-Lucent CDMA Operations, Administration and Maintenance, 401-703-407 Engineering Rules/Guidelines Flexent ™ 9927 4.0, ER_XXXX_XXXX • Power & Battery Engineering Rules for Alcatel-Lucent 9927 Distributed Base Station, ER_XXXX_XXXX_PWR .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary xiii 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 About this document .................................................................................................................................................................................................................................... Related training Alcatel-Lucent offers the following product-related training for the 9927 Distributed Base Station Outdoor Cabinet: • ______________________________________________________________ • ______________________________________________________________ To obtain technical support, documentation, and training or submit feedback The Online Customer Support (OLCS) web site, http://support.lucent.com, provides access to technical support, related documentation, related training and feedback tools. On the right side of the page is a technical support telephone number lookup tool. The site also provides account registration for new users. Site preparation checklists All site preparation activities, as well as adherence to the guidelines, should be verified before the installation of the cell site equipment. Checklists and punchlists have been provided in Appendix A, “9927 Distributed Base Station Outdoor Cabinet site preparation checklists”. These checklists and punchlists are intended to aid customers and Alcatel-Lucent personnel during a base station site Method of Procedure (MOP) walk-through before equipment installation. Utilization of the checklists helps ensure a quality installation and provides a base station site history file for later reference. The punchlist sheets are used to track completion of any outstanding site preparation items, and to aid in the project management of installation resources. Base station configuration sheets Configuration sheets are provided in Appendix C, “ 9927 Distributed Base Station Outdoor Cabinet cell site information” to aid the Customer, Equipment Engineering, and Wireless Project Management during the various stages of product deployment. The configuration sheets are used to document the base station equipment configuration, conditions, and other pertinent information for reference during product deployment, and future additions. The configuration sheets should be completed during the equipment engineering phase. Reference to this information during MOP walk-through assists with completion of the site preparation checklists. Safety information For your safety, this document contains safety statements. Safety statements are given at points where risks of damage to personnel, equipment, and operation may exist. Failure to follow the directions in a safety statement may result in serious consequences. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor xiv Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 About this document .................................................................................................................................................................................................................................... How to comment To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline (comments@alcatel-lucent.com). .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary xv 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 1 Safety Overview Purpose This chapter covers safety precautions for the 9927 Distributed Base Station Outdoor Cabinet installation. Contents Structure of safety statements 1-2 Safety - specific hazards 1-5 Product safety 1-8 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 1-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Safety Structure of safety statements .................................................................................................................................................................................................................................... Structure of safety statements Overview This topic describes the components of safety statements that appear in this document. General structure Safety statements include the following structural elements: MP CAUTION Lifting hazard SA Lifting this equipment by yourself can result in injury due to the size and weight of the equipment. Always use three people or a lifting device to transport and position this equipment. [ABC123] Item Structure element Purpose Safety alert symbol Indicates the potential for personal injury (optional) Safety symbol Indicates hazard type (optional) Signal word Indicates the severity of the hazard Hazard type Describes the source of the risk of damage or injury Safety message Consequences if protective measures fail Avoidance message Protective measures to take to avoid the hazard Identifier The reference ID of the safety statement (optional) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 1-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Safety Structure of safety statements .................................................................................................................................................................................................................................... Signal words The signal words identify the hazard severity levels as follows: Signal word Meaning DANGER Indicates an extremely hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a hazardous situation not related to personal injury. Within this IP, the safety label typically includes additional information such as the hazard type, a description of the damage that can be caused, and the steps that should be taken to avoid the hazard. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 1-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Safety Structure of safety statements .................................................................................................................................................................................................................................... WARNING Personal Injury or Damage to Equipment Failure to observe these safety precautions may result in personal injury or damage to equipment. • • • • • • • • • • • • • • • Read and understand all instructions. Follow all warnings and instructions marked on this product. Installation and maintenance procedures must be followed and performed by trained personnel only. Grounding and circuit continuity is vital for safe operation of the equipment. Never operate the equipment with grounding/bonding conductor disconnected. Install only equipment identified in the product's installation manual. Use of other equipment may result in an improper connection which could lead to fire or injury. Use caution when installing or modifying telecommunications lines. The product has multiple power inputs. Before servicing, Disconnect all inputs to reduce the risk of energy hazards. For continued protection against risk of fire, all fuses used in this product must be replaced only with fuses of the same type and rating. Never install telecommunications wiring during a lightning storm. Never install telecommunications connections in wet locations. Never touch uninsulated telecommunications wiring or terminals unless the telecommunications line has been disconnected at the interface. Never push objects of any kind into the product through slots, as they may touch dangerous voltage points or short-out parts that could result in a fire or an electrical short. Never spill liquids of any kind on the product. Slots and openings in the product are provided for ventilation. To protect it from overheating, these openings must not be blocked or covered. The product should not be placed in a built-in installation unless proper ventilation is provided. To reduce the risk of an electrical shock, do not disassemble the product. Opening and removing covers and/or circuit boards may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electrical shock when the unit is subsequently used. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 1-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Safety Safety - specific hazards .................................................................................................................................................................................................................................... Safety - specific hazards DANGER Lightning Strikes! Lightning strikes are possible during stormy weather and could result in death or severe injury. Do not work on the installation itself or on the power supply lines or antenna feeders of a 9927 during stormy weather. WARNING Energy Hazard! Some parts of all electrical installations are energized. Failure to observe this fact and the safety warnings may lead to bodily injury and property damage. For this reason, only trained and qualified personnel may install or service the installation. WARNING Energy Hazard! The power supply lines to the network element are energized. Short circuits can cause burns to the face and hands. Open the load disconnect switch in the distribution box to completely de-energize the network element. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 1-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Safety Safety - specific hazards .................................................................................................................................................................................................................................... WARNING Beryllium Oxide Poisoning Hazard! The transmitter units include components which contain beryllium oxide (BeO). In this form, BeO ceramics do not constitute a hazardous material as long as this material is not destroyed by external mechanical forces. In the event that repair work is carried out by the customer or by third parties, the following regulations must be observed: • Applicable version of the Regulation on Hazardous Materials in the Workplace • Appropriate accident prevention regulations The following must be specifically observed: • • Eating, drinking, and smoking are not permitted in workplaces where BeO ceramic components are being worked on. Wash your hands carefully under running water after working with BeO ceramic components. If the following symptoms occur, contact a physician: • • Irritation of the respiratory organs Difficulty breathing or skin irritation NOTICE Condensation may cause a short circuit! Sudden changes in the weather may lead to the formation of condensation on components. Operating the unit when condensation moisture is present can destroy the unit. Units which show signs of condensation must be dried before installation. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 1-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Safety Safety - specific hazards .................................................................................................................................................................................................................................... NOTICE ESD hazard Semiconductor elements can be damaged by static discharges. The following rules must be complied with when handling any module containing semiconductor components: • • • Wear conductive or antistatic work clothes (for example, coat made of 100% cotton). Wear grounded ESD wrist strap. Wear shoes with conductive soles. • • Leave the modules in their original packaging until ready for use. Make sure there is no difference in potential between yourself, the workplace, and the package before removing, unpacking, or packing a module. • Hold the module only by the grip without touching the connection pins, tracks, or components. • • • Place modules removed from the equipment on a conductive surface. Test or handle the module only with grounded tools on grounded equipment. Handle defective modules exactly like new ones to avoid causing further damage. DANGER Cabinet lifting hazard! When lifting cabinets, incorrect or improperly installed eyebolts will fail endangering personnel to bodily injury and destroying the equipment. Avoid using the wrong eyebolts by following these guideline: • • • • If a ½- inch eyebolt threads easily and fully into a lifting nut on the top of the cabinet, then use the ½- inch eyebolts. If not, check the threads for 12 mm eyebolts. The 12 mm eyebolt should thread all the way down without binding, until it bottoms out. A 12-mm eyebolt is too small for a ½-inch lifting nut, but will not hand thread all the way into the ½-inch nut unless forced. It will cross thread if forced, and may pull out when hoisting, presenting a serious danger. Do NOT force 12-mm eyebolts into ½-inch lifting nuts. Doing so will damage the threads of the lifting nuts. A ½-inch eyebolt will thread less than half a thread into a 12-mm lifting nut. Do NOT force ½-inch eyebolts into 12-mm lifting nuts. Doing so will damage the threads of the lifting nuts. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 1-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Safety Product safety .................................................................................................................................................................................................................................... Product safety Conformance statements See Appendix G, “Product conformance statements” for all conformance statements that apply to this product. Equipment safety Safety information for this equipment can be found on various Caution, Warning, Danger, information labels or instructions affixed to or included with the cabinet, its internal assemblies or included within this document. Informational and cautionary labels may appear near the item they address or may be grouped in a single location on the equipment. Warnings are typically adjacent to the hazard that is noted on the label. The instructions, cautions and warnings found on these labels must be understood and observed by all personnel involved with the equipment installation and maintenance. Important! Refer to “Structure of safety statements” (p. 1-2) for definitions of safety labels. Equipment safety for 1900 MHz, 4x45W (65 MHz) RRH The message below applies to the 1900 MHz, 4x45W (65 MHz) RRH. Important! These units are intended for installation only in restricted access areas, where access can only be gained by trained service personnel and through the use of a tool, lock and key or other means of security, and where access is controlled by the authority responsible for the location .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 1-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 2 2roduct overview for 9927 Distributed Base Station Outdoor cabinet Overview Purpose This chapter provides an overview of the 9927 Distributed Base Station Outdoor Cabinet. Contents Network view 2-2 Configurations 2-3 Product overview 2-4 Physical description 2-6 Components inside cabinet 2-13 Weights and dimensions of equipment 2-14 60ECv2 battery cabinet overview 2-19 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Network view .................................................................................................................................................................................................................................... Network view Overview The 9927 Distributed Base Station is a Multi-Technology, Multi-Band BTS that supports multiple access technologies. The RRHs are multi-functional and support both CDMA and LTE. For CDMA, the MT-BBU interfaces with the RRHs via optical link. The 1900 MHz (PCS) RRH operates in BC1 band and supports both LTE and CDMA. The 800 MHz RRH operates in BC10 band and supports CDMA only. The LTE RRH is hardware ready to support PCS in the G-Block. LTE in the BC10 band is not supported in initial deployment. Backhaul to the network is provided via the SAR-7705, either as: • • • • Fiber optic cable Microwave cable T1/E1 line OC3 • DS3 The -48 VDC power source inside the cabinet provides -48 VDC to the components inside the cabinet and to the RRHs. Signal flow block diagram The high-level signal flow diagram below shows how signals flow within the Alcatel-Lucent 9927 Distributed Base Station outdoor cabinet and to the RRHs and Backhaul Network. (4G Backhaul is assumed to be available at the cell site.) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Configurations .................................................................................................................................................................................................................................... Configurations Configurations In FID 15364.0, the 9927 Distributed BTS supports the following configurations: • • Up to 4 carriers/3 sectors PCS (1x-A and EVDO) with 4-BR, if PCS RRH is shared with LTE [5 MHz on G block (band class 25)]. Up to 1 carrier/3 sectors BC10 (1x-A) 2- BR . If a higher CDMA carrier count is needed, a second PCS RRH may be required. The 9927 Distributed BTS supports the following configurations: • • One MT-BBU, 8 Carriers/3 Sectors (4 Carriers 1x/1x Advance and 4 Carriers EVDO) — 3 BC1, 4x40W RRH with 4 branch Rx — 3 BC10, 2x50W RRH with 2 branch Rx — No daisy chaining One MT-BBU and one LTE BBU, 10 Carriers/3 Sectors (4 Carriers 1x/1x Advance and 4 Carriers EVDO) — 3 BC1, 4x40W LTE RRH with 4 branch Rx — 3 BC10, 2x50W RRH with 2 branch Rx — Daisy chaining .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Product overview .................................................................................................................................................................................................................................... Product overview Introduction This document supports the following product: • Alcatel-Lucent 9927 Distributed Base Station outdoor cabinet Product description for Alcatel-Lucent 9927 Distributed Base Station The Alcatel-Lucent 9927 Distributed Base Station is a multi-modal baseband cabinet, configured with Remote Radio Heads (RRHs), which provides: • CDMA in the PCS band (Bandclass 1 or 14) and 800 MHz band (Bandclass 10) • Optional LTE in the PCS band (typically Block G). Resources are shared with CDMA. The signal flow diagram below shows how CDMA, 1xEV-DO, and LTE signals are routed from the baseband cabinet to the RRHs. One sector is shown. CDMA is processed by the Digital Shelf, which uses 9927 common platform architecture. Backhaul to the Network is accomplished with T1/E1 lines, fiber optic cable, or microwave. The RRHs that are used are as follows: • • • 1900 MHz, 4x40W (25 MHz) 1900 MHz, 4x45W (65 MHz) 800 MHz, 2x50W The cabinet is equipped with a top solar shield. See Chapter 4, “Site configurations for 9927 Distributed BTS Outdoor Cabinet” for line-up configurations. Requirements The following table lists the requirements for the 9927 Distributed Base Station Outdoor Cabinet. Requirements Frequency Bands Operating Temperature Values • 3GPP2 Band Class 1 (1900 MHz – United States PCS frequency band spectrum). Blocks A,B,C,D,E,F. [FID 15597.0] • 3GPP2 Band Class 10 [FID 15599.0] • PCS – G Block (band class 25) used only for LTE. • -40 °C to +46 °C (-40 °F to +115 °F) standard • -40 °C to 50 °C (-40 °F to 122 °F) extended .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Product overview .................................................................................................................................................................................................................................... Requirements Values Power Integrated Power Battery backup Up to two 60ECv2 battery cabinets Operating Voltage -48 VDC Sectors 3,sector T1/E1 Facilities Up to 16 T1/E1s (optional) User Alarms 32 for external User Alarms GPS Antenna Yes .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... Physical description Diagram The figure below shows the 9927 Distributed BTS outdoor cabinet with the front door closed. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... The figure below illustrates the position of each component inside the 9927 Distributed BTS cabinet. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... The following figure is a left-side view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... The following figure is a front view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... The following figure is a right-side view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. Description This 9927 Distributed Base Station Outdoor Cabinet features Fresh Air Cooling (FAC). The FAC uses filter membrane technology to achieve clean-room conditions inside the baseband cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Physical description .................................................................................................................................................................................................................................... The 9927 Distributed Base Station Outdoor Cabinet is equipped with the following features: • Filter Life Alarm - The cabinet has a pressure sensing alarm that sends an alarm when more than the normal amount of suction is needed to draw air into the baseband cabinet. The interior of the baseband cabinet is held at negative pressure (lower than ambient air pressure). All openings on the cabinet must be sealed to maintain negative pressure inside the baseband cabinet when the baseband cabinet is in operation. Important! Refer to Appendix D, “Guidelines for lifting and moving cabinets ” for guidelines regarding lifting and moving of the cabinet. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Components inside cabinet .................................................................................................................................................................................................................................... Components inside cabinet Purpose This section lists the components that can be populated in the 9927 Distributed Base Station Outdoor Cabinet. 9927 Distributed Base Station Outdoor Cabinet components The table below lists the components inside the 9927 Distributed Base Station Outdoor Cabinet. Components inside 9927 Distributed Base Station Outdoor Cabinet The 9927 Distributed Base Station Outdoor Cabinet can contain the following modules: • SAR 7705 SAR-8 (expandable) or 7705 SAR-F (fixed). 7705 SAR-M (future). • Two 7210 SAS M (-48 VDC) -- only for microwave backhaul • LTE TDD, 2.6 GHz (Optional) or • CDMA MT-BBU • CDMA MT-BBU Growth • One or two -48 VDC PDPs -- second unit is optional. Needed only for cabinet is upgrade. • 4-Position SEC-B Tray (ETSI) -- used only with T1/E1 Backhaul. T1/E1 Backhaul is via the SAR. • Thermal Switch for Power Injectors • Microwave Power Injector (PIB), -48 VDC • ACPDA • GFCI Convenience Outlet • Heater Assembly • User Alarm interface • Alarms .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Weights and dimensions of equipment .................................................................................................................................................................................................................................... Weights and dimensions of equipment Introduction This section provides physical specifications for one configuration of the 9927 Distributed Base Station Outdoor Cabinet. The weights and dimensions, listed in the table below, include the top solar shield. 9927 Distributed Base Station Outdoor Cabinet weights and dimensions The table below lists the weights and dimensions for a half-loaded and fully-loaded 9927 Distributed Base Station Outdoor Cabinet. Cabinets Configuration 9927 Distributed Base Station Outdoor Cabinet with Integrated Power Half loaded • CDMA • One BBU • One 7210 • One SAR 8 • Three DC-DC convertors Shipped Weight including pallet (estimate) CDMA • Four BBUs • Two 7210s • One SAR 8 • Six DC-DC convertors • 8 Injectors 470 kg 430 kg (1033 lbs) (945 lbs) Reference Dimensions (Width x Depth x Height) 900 mm x 960 mm x 1925 mm (35.4 inches x 37.8 inches x 75.8 inches) Fully loaded • Maximum Installed Weight (estimate) 529 kg 489 kg (1162 lbs) (1074 lbs) 60ECv2 battery cabinet weights and dimensions The table below provides the weights and dimensions of the 60ECv2 battery cabinet. Cabinets Configuration 60ECv2 Battery System 60ECv2 battery cabinet equipped with 20 12IR145 batteries Shipped Weight including pallet (estimate) 195 (430) Maximum Installed Weight (estimate) Reference Dimensions (Width x Depth x Height) 1284 (2830) 760x790x1500 (30 x 31 x 60) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-14 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Weights and dimensions of equipment .................................................................................................................................................................................................................................... Component weights The following table provides approximate weights for batteries and other miscellaneous hardware. Item Weight 12IR145 battery 45 kg (100 lbs) KS24734 Rectifier 6 kg (14 lbs) Pallet 40 kg (88 lbs) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-15 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Weights and dimensions of equipment .................................................................................................................................................................................................................................... 9927 Distributed Base Station Outdoor Cabinet dimensions The following figure is a left-side view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-16 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Weights and dimensions of equipment .................................................................................................................................................................................................................................... The following figure is a front view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-17 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet Weights and dimensions of equipment .................................................................................................................................................................................................................................... The following figure is a right-side view of the 9927 Distributed Base Station Outdoor Cabinet. The dimensions are shown in mm and inches. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-18 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet 60ECv2 battery cabinet overview .................................................................................................................................................................................................................................... 60ECv2 battery cabinet overview 60ECv2 description This topic provides a description of the 60ECv2 battery cabinet. The optional 60ECv2 battery cabinet provides battery backup for the 9927 Distributed Base Station Outdoor Cabinet. The 60ECv2 battery cabinet can contain up to (20) 12IR-145 batteries. Up to two 60ECv2 battery cabinets can be installed to the right of the 9927 Distributed Base Station Outdoor Cabinet. Front View Rear View Hole for Padlock (Top View) Unlock Lock (4 Places) Unlock Lock (2 Places) Hole for Padlock (Top View) 25 mm ( # 2 AWG ) Ground/Earth Lug to Ground/Earth Bar (2 Places) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 2-19 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for 9927 Distributed Base Station Outdoor cabinet 60ECv2 battery cabinet overview .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 2-20 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 3 Product overview for RRHs Overview Purpose This chapter provides an overview of the Alcatel-Lucent Remote Radio Head, with optional power and battery back up. Contents Typical RRH/antenna array 3-2 External views of RRHs 3-3 Detailed physical description 3-6 Functional description of RRHs 3-18 Antenna Remote Electronic Tilt (RET) — FID 13019.36 3-19 RRH mounting configurations 3-20 RRHs and related equipment 3-23 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Typical RRH/antenna array .................................................................................................................................................................................................................................... Typical RRH/antenna array Typical RRH/antenna arrays on tower The figure below shows a typical RRH/antenna array on a tower. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs External views of RRHs .................................................................................................................................................................................................................................... External views of RRHs Orthogonal view of 1900 MHz, PCS, 4x40W (25 MHz) RRH The following figure is an orthogonal view of the 1900 MHz, PCS, 4x40W (25 MHz) RRH. Dimensions are shown in mm. 330 (13.0) 580 (22.8) 440 (17.3) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs External views of RRHs .................................................................................................................................................................................................................................... Orthogonal view of 1900 MHz, PCS, 4x45W (65 MHz) RRH The following figure is an orthogonal view of the 1900 MHz, PCS, 4x45W (65 MHz) RRH. Dimensions are shown in mm. 272 637 282 Orthogonal view of 800 MHz, 2x50W RRH (OEM1) The following figure is an orthogonal view of the OEM1, 800 MHz, 2x50W RRH. Dimensions are shown in mm. 500 800 Mhz (23 kg/50.6 lbs) 385 330 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs External views of RRHs .................................................................................................................................................................................................................................... Orthogonal view of 800 MHz, 2x50W RRH (OEM2) The following figure is an orthogonal view of the OEM2, 800 MHz, 2x50W RRH. Dimensions are shown in mm. 330 400 800 Mhz (23 kg/50.6 lbs) 255 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Detailed physical description Identify RRHs according to front, top and bottom views Use the table below to identify each RRH using the front, top and bottom views. Front, top and bottom views of RRHs-- for identification Frequency Front View Top View Bottom View 1900 MHz PCS Refer to “Front view of 1900 MHz, PCS, 4x40W (25 MHz) RRH” (p. 3-7) Refer to “Top view of 1900 MHz, PCS, 4x40W (25 MHz) RRH ” (p. 3-8) Refer to “Bottom view of 1900 MHz, PCS, 4x40W (25 MHz) RRH ” (p. 3-9) 1900 MHz PCS 4X45W, 65 MHz Refer to “Front view of 1900 MHz, PCS, 4x45W (65 MHz) RRH” (p. 3-10) Refer to“Top view of 1900 MHz, PCS, 4x45W (65 MHz) RRH ” (p. 3-11) Refer to“Bottom view of 1900 MHz, PCS, 4x45W (65 MHz) RRH ” (p. 3-12) OEM1, 800 MHz, 2x50W Refer to “Front view of OEM1, 800 MHz, 2x50W RRH” (p. 3-13) Refer to “Top view of OEM1, 800 MHz, 2x50W RRH” (p. 3-13) Refer to “Bottom view of OEM1, 800 MHz, 2x50W RRH” (p. 3-14) OEM2, 800 MHz, 2x50W Refer to “Front view of OEM2, 800 MHz, 2x50W RRH” (p. 3-14) Refer to “Top view of OEM2, 800 MHz, 2x50W RRH” (p. 3-15) Refer to “Bottom view of OEM2, 800 MHz, 2x50W RRH” (p. 3-15) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Front view of 1900 MHz, PCS, 4x40W (25 MHz) RRH The following figure is a front view of the 1900 MHz PCS, 4x40W (25 MHz) RRH. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Top view of 1900 MHz, PCS, 4x40W (25 MHz) RRH The following figure is a top view of the 1900 MHz PCS, 4x40W (25 MHz) RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Bottom view of 1900 MHz, PCS, 4x40W (25 MHz) RRH The following figure shows the connectors on the bottom of the 1900 MHz, PCS, 4x40W (25 MHz) RRH. Tx2 MON AUX Rx2 AUX Rx1 CPRI PRI CPRI SEC ASIG ALM Tx2 MON .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Front view of 1900 MHz, PCS, 4x45W (65 MHz) RRH The following figure is a front view of the 1900 MHz, PCS, 4x45W (65 MHz) RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Top view of 1900 MHz, PCS, 4x45W (65 MHz) RRH The following figure is a top view of the 1900 MHz, PCS, 4x45W (65 MHz) RRH. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Bottom view of 1900 MHz, PCS, 4x45W (65 MHz) RRH The following figure shows the connectors on the bottom of the 1900 MHz, PCS, 4x45W (65 MHz) RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Front view of OEM1, 800 MHz, 2x50W RRH The following figure is a front view of the OEM1, 800 MHz, 2x50W RRH. Top view of OEM1, 800 MHz, 2x50W RRH The following figure is a top view of the OEM1, 800 MHz, 2x50W RRH. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Bottom view of OEM1, 800 MHz, 2x50W RRH The following figure is a bottom view of the OEM1, 800 MHz, 2x50W RRH. Front view of OEM2, 800 MHz, 2x50W RRH The following figure is a front view of the OEM2, 800 MHz, 2x50W RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-14 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Top view of OEM2, 800 MHz, 2x50W RRH The following figure is a top view of the OEM2, 800 MHz, 2x50W RRH. Bottom view of OEM2, 800 MHz, 2x50W RRH The following figure shows the connectors on the bottom of the OEM2, 800 MHz, 2x50W RRH. AUX RX2 AUX Rx1 CPRI PRI CPRI PRI STATUS Tx1 MON Tx2 MON ALM -48 V IN ALD Bottom view of 1900 MHz, 4x40W (65 MHz) RRH Get figs from attachment! .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-15 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Connectors on 1900 MHz RRH The following table lists the connectors on the 1900 MHz RRH and the function of each connector. Connectors on 1900 MHz RRH Connector Function TX1/RX1 (25 MHz — top of RRH/ 65 MHz — bottom of RRH) Transmit and receive, antenna path 1 TX2/RX2 (25 MHz — top of RRH/ 65 MHz — bottom of RRH) Transmit and receive, antenna path 2 TX3/RX3 (25 MHz — top of RRH/ 65 MHz — bottom of RRH) Transmit and receive, antenna path 3 TX4/RX4 (25 MHz — top of RRH/ 65 MHz — bottom of RRH) Transmit and receive, antenna path 4 Grounding Points (on left and right side of 25 MHz RRH)RRH grounding points [Left and Right for 25 MHz / Bottom for 65 MHz] Connect 6 AWG (outdoor) or 2 AWG (indoor) ground wire terminated with 2–hole lug to RRH. AUX RX1 Antenna-sharing port AUX RX2 N/A CPRI PRI CPRI optical main port CPRI SEC CPRI optical daisy-chained port AISG Remote Electronic Tilt (RET) ALM 2 x 8 pin circular TX1 MON TX2 MON -48 V RRH connectors on OEM2 RRH The following table lists the connectors on the OEM2 RRH and the function of each connector. Connectors on OEM2 RRH Connector Function TX/RX1 (at top of RRH) Transmit and receive, antenna path 1 TX/RX2 (at top of RRH) Transmit and receive, antenna path 2 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-16 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Detailed physical description .................................................................................................................................................................................................................................... Connector Function Grounding Points (on left and right sides of RRHs)RRH grounding points Grounding point AUX RX1 Antenna-sharing port AUX RX2 Antenna-sharing port CPRI PRI CPRI optical main port CPRI SEC CPRI optical daisy-chained port STATUS ALM 2 x 8 pin circular TX1 MON TX2 MON ALD -48 V IN –48 VDC input power .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-17 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs Functional description of RRHs .................................................................................................................................................................................................................................... Functional description of RRHs General description The three RRHs pictured below are used with 800 MHz CDMA, PCS CDMA, and LTE technologies. Product configurations The configurations offered in this release are as follows: • One sector (consists of two 1900 MHz RRHs and one 800 MHz RRH per sector) Product capabilities The product capabilities for the RRHs are as follows: • • 1900 MHz — PCS CDMA — LTE — Outdoor, -48 VDC 800 MHz — CDMA — Outdoor, -48 VDC .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-18 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs Antenna Remote Electronic Tilt (RET) — FID 13019.36 .................................................................................................................................................................................................................................... Antenna Remote Electronic Tilt (RET) — FID 13019.36 General description FID-13019.36 introduces a Remote Radio Head (RRH) with an associated RET/ALD controller that operates the RET. The RET consists of an actuator motor with supporting control electronics. The RET adjusts the antenna down-tilt angle by electrically changing the antenna phase angle. By altering the phase of the antenna signal, the RET also tilts the antenna beam.. This results in decreased main, side and backward lobes. This overcomes the shortcomings of mechanical tilt antennas, where the whole antenna is physically tilted. This system moves the backward lobe in upward direction and distorts the side-lobe patterns. AISG interface on RRH The RRHs are equipped with an Antenna Interface Standards Group (AISG) power and signaling interface connector that supports third party Antenna Remote Electronic Tilt (RET) equipment. The PCS RRH 4x and 800 MHz RRH 2x are hardware ready to support the third party RET. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-19 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs RRH mounting configurations .................................................................................................................................................................................................................................... RRH mounting configurations RRH mounting configurations The RRHs can be mounted on a: • • Pole Wall • Floor Stand. Pole mounted RRHs The following figure shows the 800 MHz/1900 MHz RRH configuration mounted on a pole. The 800 MHz RRH is mounted directly above the 1900 MHz RRH. Each RRH is equipped with a lifting handle. The antenna assembly is mounted opposite the RRHs. Wall mounted RRHs The following figure shows a typical RRH mounted on a wall with Unitstruts. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-20 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs RRH mounting configurations .................................................................................................................................................................................................................................... Floor Stand mounted RRHs [800 MHz and 4x40W (25 MHz) PCS] he following figure shows the floor stand that is used with 800 MHz and 4x40W (25 MHz) PCS RRHs. The wall mounting bracket is shown attached. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-21 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs RRH mounting configurations .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-22 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... RRHs and related equipment Weights and dimensions This topic covers the weights and dimensions for RRHs and related equipment. Weights and dimensions of RRHs and accessories The following table provides weights and dimensions for the RRHs and floor stand. RRH type or accessory Description Estimated maximum installed weight without mounting brackets kg (lbs) Height mm (inches) Width mm (inches) Depth mm (inches) RRH, 800 MHz, OEM1 CDMA/LTE, Dual Technology, 2 x 50 Watts 23 (50.6) 500 (19.7) 330 (13.0 ) 385 (15.2 ) 23 (50.6) 400 (15.8) 330 (13.0 ) 255 (10.0 ) RRH, 800 MHz, OEM2 RRH, 1900 MHz, 25 MHz per Tx port CDMA/LTE, Dual Technology, 4 x 40 Watts 47 (104) [includes 2 RRHs and mounting brackets] 580 (22.8) 330 (13.0 ) 440 (17.3) RRH. 1900 MHz, 65 MHz per Tx port CDMA/LTE, Dual Technology, 4 x 45 Watts 60 (132) 637 (25.1 ) 282 (11.1 ) 272 (10.7 ) 509 (20.1) 360 (14.2) 1226 (48.3) Notch Filter 4 ( 8.8) Floor Stand n/a 23 (51) Miscellaneous hardware weights The following table provides approximate weights for miscellaneous hardware. Item Weight kg (lbs) Pallet ____ (___) Wall Bracket (RRH) 3.5 (7.7) Side Support Bracket 3.5 (7.7) Pole Bracket (Low Profile) 4.3 (9.5) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-23 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... Item Weight kg (lbs) Floor Stand (RRH) 23 (50) Grounding points on RRHs The grounding points on the 1900 MHz and 800 MHz RRHs are located at the bottom, on the left and right sides. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-24 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... The following figure shows how grounding wire is routed to the RRHs. 850 RRH (Side View) Rear side AWS, PCS RRH (Front View) Front side Ground connection at top of RRH (on left side) Ground connection at bottom of RRH (left or right side may be used) Ground connection at top of RRH (on right side) Ground connection at bottom of RRH (left or right side may be used) Surge protector Surge protector 6 ft Ground cable, #6 AWG 6 ft Ground cable, #6 AWG Ground bus bar Ground bus bar Note: For antenna sharing 850, AWS, PCS RRHs, ground connection for surge protector must be within 6 feet of a ground bus bar. The following figures show the grounding points on the OEM2 RRH. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-25 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... The left–side grounding point on the OEM2 RRH is located at the left bottom, as shown in the figure below. The right–side grounding point on the OEM2 RRH is located at the right bottom, as shown in the figure below. The following figures show the grounding points on the 1900 MHz RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-26 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... The left-side grounding point on the 1900 MHz, 4x40W RRH is located at the left bottom, as shown in the figure below. The right–side grounding point on the 1900 MHz, 4x40W RRH is located at the right bottom, as shown in the figure below. The following figures shows the grounding points on the 1900 MHz, 4x45W RRH. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 3-27 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product overview for RRHs RRHs and related equipment .................................................................................................................................................................................................................................... The grounding points on the 1900 MHz, 4x45W RRH are located on the bottom, as shown in the figure below. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 3-28 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 4 S4ite configurations for 9927 Distributed BTS Outdoor Cabinet Overview Purpose This chapter describes configurations and site layouts for the 9228 Distributed Base Station site. Contents Line-up configuration 4-2 Line-up configuration 4-3 Site layout 4-4 9927 Distributed Base Station Outdoor Cabinet site layout 4-5 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 4-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site configurations for 9927 Distributed BTS Outdoor Overview Cabinet Line-up configuration .................................................................................................................................................................................................................................... Line-up configuration Overview Purpose This section discusses the line-up configuration for the 9927 Distributed Base Station Outdoor Cabinet. Contents Line-up configuration 4-3 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 4-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site configurations for 9927 Distributed BTS Outdoor Line-up configuration Cabinet Line-up configuration .................................................................................................................................................................................................................................... Line-up configuration Purpose This section describes the only line-up that is available for the 9927 Distributed Base Station Outdoor Cabinet. Line-up At the present time, the only line-up available for the 9927 Distributed Base Station Outdoor Cabinet consists of the 9927 Distributed Base Station Outdoor Cabinet and up to two 60ECv2 battery cabinets. The block diagram below shows the line-up for the 9927 Distributed Base Station Outdoor Cabinet and two 60ECv2 battery cabinets. LEGEND Optional P Power 9927 Distributed BTS Outdoor Cabinet 60ECv2 Battery Cabinet 60ECv2 Battery Cabinet .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 4-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site configurations for 9927 Distributed BTS Outdoor Overview Cabinet Site layout .................................................................................................................................................................................................................................... Site layout Overview Purpose This section shows the site layout for the 9927 Distributed Base Station Outdoor Cabinet. Contents 9927 Distributed Base Station Outdoor Cabinet site layout 4-5 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 4-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site configurations for 9927 Distributed BTS Outdoor 9927 Distributed Base Station Outdoor Cabinet site layout Cabinet Site layout .................................................................................................................................................................................................................................... 9927 Distributed Base Station Outdoor Cabinet site layout Purpose This section shows how the 9927 Distributed Base Station Outdoor Cabinet and two 60ECv2 battery cabinets can be arranged on a concrete pad. Mounting options The 9927 Distributed Base Station Outdoor Cabinet can be mounted in the following manner: • On a concrete pad (with optional mounting bases) • On a rooftop (may be supported by a mounting structure or raised platform provided by the customer) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 4-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site configurations for 9927 Distributed BTS Outdoor 9927 Distributed Base Station Outdoor Cabinet site layout Cabinet Site layout .................................................................................................................................................................................................................................... New site installation of 9927 Distributed Base Station Outdoor Cabinet 9927 Distributed Base Station Outdoor Cabinet and two 60ECv2 battery cabinets The figure below shows how the 9927 Distributed Base Station Outdoor Cabinet and two 60ECv2 battery cabinets can be situated on a concrete pad. Shown also are the conduits, cables, and support structure associated with the installation. (This configuration applies to a new site installation.) JUMPER CABLE SUPPORT STRUCTURE ASSEMBLY (CUSTOMER-PROVIDED) 1 OR 2 60ECv2 BATTERY CABINETS (2nd BATTERY CABINET IS OPTIONAL) 9927 DISTRIBUTED BTS OUTDOOR CABINET GPS SURGE PROTECTOR GPS ANTENNA CABLE WITH SURGE PROTECTION 1 ½ INCH CONDUIT (FOR -48 VDC AND FIBER OPTIC CABLE TO DC DISTRIBUTION/ POWER MANAGEMENT BOX ) 1 ½ INCH AC CONDUIT REAR CONCRETE PAD OR ROOFTOP PLATFORM (CUSTOMER-SUPPLIED) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 4-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 5 5 asic site preparation requirements and footprints for 9927 Distributed Base Station outdoor cabinet ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Distributed Base Station outdoor cabinet Overview .................................................................................................................................................................................................................................... Overview Purpose This chapter provides the site requirements for the installation site for 9927 Distributed Base Station Outdoor Cabinet and the procedures that may be performed to prepare the installation site. Contents Site requirements for 9927 Distributed Base Station Outdoor cabinet 5-3 Environmental requirements 5-4 Site requirements 5-6 Mounting options 5-9 Support structure, ice bridge and service access clearances 5-11 Anchoring requirements 5-12 Anchoring footprints 5-13 Site preparation procedures 5-15 Drill anchor holes 5-16 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Overview Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Site requirements for 9927 Distributed Base Station Outdoor cabinet Overview Purpose This section describes the requirements for the installation site for the 9927 Distributed Base Station Outdoor Cabinet. Contents Environmental requirements 5-4 Site requirements 5-6 Mounting options 5-9 Support structure, ice bridge and service access clearances 5-11 Anchoring requirements 5-12 Anchoring footprints 5-13 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Environmental requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Environmental requirements Environmental requirements for outdoor installations Outdoor cabinet installations are exposed to variations in temperature, humidity, and ventilation. The 9927 Distributed Base Station cabinet has been weather-hardened. When equipped with a heat exchanger, the cabinet will operate under the conditions described in the table below. Condition Specification Operating temperature -40 °C to +46 °C (-40 °F to +115 °F) Extended operating temperature -40 °C to 50 °C (-40 °F to 122 °F) Relative humidity 5 to 100% (non-condensing but not to exceed 0.024 kg water/kg of dry air) Enclosure rating Type 3R (NEMA) IP35 (IEC 60529) Acoustic noise suppression 65 dBA at 25 °C (77 °F) and sea level Operating altitude -60.96 to 1798 m (-200 to 5,900 ft.) above sea level Extended operating altitude -60.96 to 3048 m (-200 to 10,000 ft.). An operating temperature de-rating of 1 °C per 1000 feet above 6000 feet is allowed Wind driven rain Refer to Telcordia GR-487-CORE Dust and water ingress Refer to Telcordia GR-487-CORE Bullet resistance Refer to Telcordia GR-487-CORE Wind resistance Refer to Telcordia GR-487-CORE Storage requirements Refer to Telcordia GR-63-CORE, Section 4.1.1 Minimum installation temperatures Insulation on power cables tends to crack when handled at extremely cold temperatures. Minimum installation temperatures have been established for this reason. The following wire insulation types are affected : • Class B: THHN type insulation (T90 NYLON type insulation in Canada). .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Environmental requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet The minimum storage and working temperatures are as follows: • • Storage prior to installation: 20 °C (68 °F) Working (Installation): -25 °C (-13 °F) Installations at -25 °C (-13 °F) or below If shelter is available, do the following: • • • Store cables in a heated area (20 °C [68 °F] or higher) for 24 hours prior to installation. Keep cables sheltered from wind and temperatures below -25 °C (-13 °F) during installation. It is recommended to perform the installation in a heated tent. If shelter cannot be provided, the following cable along with the associated hardware is recommended. The size of the cable determines the correct tool to use, as well as the inside diameter of the lug and the insulating sleeve. • • • • Industrial Wire & Cable Corp. Type MTW Machine Tool Wire FCI Terminal Lug (or equivalent), 3/8" Bolt Size, Straight, 2-Hole, 1" Center to Center FCI Terminal Lug (or equivalent), 1/4" Bolt Size, Straight, 2-Hole, 5/8" Center to Center FCI Terminal Lug (or equivalent), 5/16 Bolt Size, Straight, One-Hole Panduit (or equivalent) Type HSTTV 75-T2 Insulating Sleeve, Heat Shrink, Red • Panduit (or equivalent) Type HSTTV 75-T Insulating Sleeve, Heat Shrink, Black • .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Site requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Site requirements General requirements The following general requirements must be met before the installation of the 9927 Distributed Base Station site can be started: • • • • • • • • • • • • • • An appropriate installation site must be selected. For more information, see “Mounting options” (p. 5-9). Adequate clearance must be provided for service access, as described in “Support structure” (p. 5-11). The environment must comply with “Environmental requirements for outdoor installations” (p. 5-4). Cabinet anchor holes must be drilled, as described in “Drill anchor holes” (p. 5-16). Support structure and ice bridge (if required) must be installed, as described in “Support structure, ice bridge and service access clearances” (p. 5-11).sss Tower light power must be installed (if required). Tower light alarm must be installed (if required). Conduits must be installed, as described in “Conduit requirements” (p. 5-7). AC electric service for the 9927 Distributed Base Station Outdoor Cabinet must be installed as described in Chapter 8, “Electrical power requirements for 9927 Distributed Base Station Outdoor Cabinet”. DC electric service for the RRHs must be installed as described in Chapter 8, “Electrical power requirements for 9927 Distributed Base Station Outdoor Cabinet”. GPS antenna runs must be installed, as described in Chapter 10, “Site preparation requirements for 9927 Distributed Base Station Outdoor cabinet GPS antenna and microwave antenna cable”. Surge protection for antennas must be installed, as described in Chapter 10, “Site preparation requirements for 9927 Distributed Base Station Outdoor cabinet GPS antenna and microwave antenna cable” Grounding electrode system must be installed with sufficient pigtails, as described in Chapter 12, “Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet”. T1/E1 and User Alarm facilities must be installed at demarcation point as described in Chapter 14, “Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet”. Refer to Appendix A, “9927 Distributed Base Station Outdoor Cabinet site preparation checklists” of this document for checklists of detailed requirements. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Site requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Conduit requirements Rigid conduits Rigid conduits are used to bring various types of cables to the installation site. It is the responsibility of the customer to provide the rigid conduit and install it as part of site preparation. The following table describes the rigid conduits that are required: Required conduit Purpose Conduit specifications AC power supply conduit AC power cables are brought to the installation site in the AC power supply conduit. 1 1/2-inch rigid conduit must be steel NIU conduit T1/E1 cables and the User Alarm cable are terminated at the Network Interface Unit (NIU) and brought to the installation site in the NIU conduit. 1-inch rigid conduit must be steel Flexible conduit Flexible conduit is used in installation to connect cables to the 9927 Distributed Base Station Outdoor Cabinet. It is the responsibility of the customer to provide all flexible conduit and associated fittings to the installer. The following table describes the flexible conduits that are required: Required conduit Purpose Required Supplies AC conduit Connects AC power supply to 9927 Distributed Base Station Outdoor Cabinet. 1 1/2-inch liquid-tight flexible metal conduit and 2 inch connectors T1/E1 conduit Connects T1/E1 and User Alarms to 9927 Distributed Base Station Outdoor Cabinet 1-inch liquid-tight flexible metal conduit and 2 inch connectors Architectural considerations All architectural considerations shall comply with all applicable national and local codes, including the following: • Uniform Building Code (UBC) • • Building Officials and Code Administrators (BOCA) Southern Uniform Building Code (SUBC) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Site requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet • • • American Concrete Institute (ACI) American National Standard Institute (ANSI) American Standard Testing Methodology (ASTM) • National Fire Protection Association (NFPA) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Mounting options Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Mounting options Purpose This topic describes the mounting options for 9927 Distributed Base Station Outdoor Cabinet. Structural requirements Floor loading, roof loading, and foundations must be considered during site preparation. In some cases, the cell site equipment will not rest directly on the concrete pad, floor, or rooftop. In those cases, the cell equipment will need to be supported by an intermediate structure that is fastened directly to the mounting surface. The cabinets must be supported along all four edges. The support structure must be designed in compliance with BOCA national building codes and all other applicable codes. If the cabinets are elevated more than 152.4 mm (6 inches) above the floor surface, it is recommended that a platform be placed under the cabinets to provide a safe and convenient work surface for technicians. The customer may use a custom-designed platform and will be responsible for supplying the 12 mm (1/2 inch.) bolt size hardware. A platform bolt-down kit is available from Alcatel-Lucent. Concrete pad requirements If cabinets will be installed on a concrete pad, the concrete pad must be supplied as part of site preparation and must meet the following requirements: • Minimum pressure = 175 kg/cm2 (2500 psi) • Minimum thickness = 114 mm (4.5 inches) • • • The surface of the concrete pad must comply with national and local building codes. The concrete pad must be able to support the maximum weight of the cabinets. The concrete pad must be able to allow drilling of up to 100 mm anchor holes to secure the cabinets to the pad. The concrete pad must be level and the total variation of the top flat surface must be ±1/4 inch. • Rooftop requirements The following requirements must be met when cabinets are installed on the roof of a building: • • The building must comply with Building Officials and Code Administrators (BOCA) building codes. Additional support structure is required. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Mounting options Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet • • The rooftop must be able to support the maximum weight of the cabinets and other auxiliary equipment. Adequate clearance must be provided to transport the cabinet to the roof. Raised platform Rooftop installations must be supported by a customer-provided mounting structure or raised platform. It is the responsibility of the customer to design the rooftop platform. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Support structure, ice bridge and service access clearances Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Support structure, ice bridge and service access clearances Purpose This topic describes the site preparation requirements with regard to the support structure and ice bridge for the 9927 Distributed Base Station Outdoor Cabinet. Support structure Support brackets and support structures must meet the requirements specified in this document and all current applicable ASTM specifications. A customer-supplied support structure shall be used to support GPS antenna cable, hybriflex cables, microwave cables, the ice bridge, and grounding cables. Ice bridge At installations where falling ice can damage cables, a customer-supplied ice bridge should be used to support the Hybriflex and microwave cable runs, and to protect them from falling ice. The height and position of the ice bridge must not interfere with access to the connections at the left or right of the 9927 Distributed Base Station cabinet. Service access clearances Proper clearance must be provided around the cabinet to allow for service access. The following minimum clearances are recommended around the 9927 Distributed BTS outdoor cabinet. The clearances are given when looking at the front of the cabinet. Side Clearance Reason Front 36 inches Front connections, opening of door Left 6 inches T1, User Alarm, cable gland connections Right 6 inches DC Distribution/Fiber Management Box, 60ECv2 Rear 36 inches Rear connections .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Anchoring requirements Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Anchoring requirements Overview Cabinet anchoring must meet all requirements of the local codes, taking into consideration the seismic zone of the installation site. Anchor specifications Use the following table to determine the type of anchor to use, and the hole size and depth required for the anchor hole. Equipment Seismic Zone Anchor Type Number of Anchors Required Hole Size/Depth Anchor set before or after unit placement? 9927 Distributed Base Station Outdoor Cabinet 0, 1, 2 1/2" drop-in anchor 16 mm (5/8 inch) bit /50 mm (2 inches) deep Before 3, 4 12 mm expansion stud anchor 18 mm (11/16 inch) bit /101 mm (4 inches) minimum deep1 After 60ECv2 battery cabinet 0, 1, 2 1/2 inch drop-in anchor 16 mm bit (5/8 inch) /50 mm (2 inches) deep Before 3, 4 12 mm expansion stud anchor 18 mm (11/16 inch) bit / minimum 101 mm (4 inches) deep1 After Notes: 1. If a 101 mm (4 inch) hole depth cannot be attained for a 12 mm expansion stud anchor, a 76 mm (3 inch) hole depth can be used. To make the anchor fit the shorter depth, a spacer may be removed from the anchor assembly and 25 mm (1 inch) may be cut from the end of the threaded rod prior to setting the anchor. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Anchoring footprints Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet Anchoring footprints New site anchoring footprint for 9927 Distributed Base Station Outdoor Cabinet and 60ECv2 battery cabinet The diagram below is an anchoring footprint for the 9927 Distributed Base Station Outdoor Cabinet and 60ECv2 battery cabinet when located side by side. Anchoring footprint for 60ECv2 battery cabinet The following diagram shows the 60ECv2 battery cabinet anchoring footprint required for site preparation. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Anchoring footprints Distributed Base Station outdoor cabinet Site requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor cabinet .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-14 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Overview Distributed Base Station outdoor cabinet Site preparation procedures .................................................................................................................................................................................................................................... Site preparation procedures Overview Purpose This section contains the procedures that must be performed to prepare the site for installation of the 9927 Distributed Base Station Outdoor Cabinet. Contents Drill anchor holes 5-16 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-15 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Drill anchor holes Distributed Base Station outdoor cabinet Site preparation procedures .................................................................................................................................................................................................................................... Drill anchor holes Purpose Use this procedure to drill anchor holes in a concrete surface for the following: • • 9927 Distributed Base Station Outdoor Cabinet Mounting bases Related information See the following topics in this document: • • “Anchoring requirements” (p. 5-12) “Anchoring footprints” (p. 5-13) Steps Use the following procedure to drill the anchor holes in a concrete surface. ................................................................................................................................................................................................... If using the optional drilling template, place the template in position. ................................................................................................................................................................................................... Mark the surface for all cabinets to be installed. Refer to “Anchoring footprints” (p. 5-13) for cabinet anchoring dimensions. ................................................................................................................................................................................................... If using the optional drilling template, remove the template. ................................................................................................................................................................................................... Drill the anchor holes to the proper size and depth as specified in “Anchoring requirements” (p. 5-12). Refer to the following figure for the anchor hole drilling method. DEPTH GAUGE ANCHOR .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-16 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Drill anchor holes Distributed Base Station outdoor cabinet Site preparation procedures .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... Vacuum out the holes. ................................................................................................................................................................................................... Tape over the open holes to prevent debris from falling inside. Important! Do not install the anchors at this time. Anchors will be installed as part of cabinet installation by equipment installers. E................................................................................................................................................................................................... N D O F S T E P S .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 5-17 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for 9927 Distributed Base Station outdoor cabinet Drill anchor holes .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 5-18 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 6 6 asic site preparation requirements and footprints for RRHs Overview Purpose This chapter discusses how to prepare the site for installation of RRHs. Contents Site requirements for RRHs 6-2 Storing RRHs in non-powered state 6-3 Environmental requirements 6-4 Site requirements for RRHs 6-5 RRH cabinet clearances 6-6 Site requirements for pole mount installations 6-8 Site requirements for wall mount installations 6-11 Site requirements for floor stand installations 6-16 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Overview RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Site requirements for RRHs Overview Purpose This section describes the site requirements at the installation site for RRHs Contents Storing RRHs in non-powered state 6-3 Environmental requirements 6-4 Site requirements for RRHs 6-5 RRH cabinet clearances 6-6 Site requirements for pole mount installations 6-8 Site requirements for wall mount installations 6-11 Site requirements for floor stand installations 6-16 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Storing RRHs in non-powered state RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Storing RRHs in non-powered state Purpose Important! Alcatel-Lucent does not provide support for RRHs that have been left non-powered for an extended period of time and not stored in an environmentallycontrolled space. The Alcatel-Lucent Design Team provides the following guidelines to minimize the build-up of moisture inside RRHs that must remain in the non-powered state for an extended period of time. This section describes how to properly store RRHs that have been delivered to an installation site but have not been yet installed. The main concern with non-powered cabinets is condensation inside the cabinet, which can result in corrosion or electrical shorts. The location and length of storage time determine the severity of the problem. These guidelines include prevention and drying steps. Moisture problem prevention To prevent moisture from collecting inside non-powered RRHs that are in storage, all openings and connectors must be tightly sealed. The units should also be covered with a waterproof tarp. The tarp should be sealed with duct tape. A desiccant packet should be placed under the tarp to absorb moisture. The amount of desiccant is related to storage time and to size of the unit. A visual check should be made to check for condensation after uncovering the tarp. Additional storage requirements After performing the procedures above, ensure that the following steps are taken: • The cabinet must be properly grounded. • • • RF cables should not be connected to the RRH. Any connectors must be sealed with watertight plugs. All holes must be plugged with watertight plugs. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Environmental requirements RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Environmental requirements Environmental requirements for outdoor installations In an outdoor installation temperature, humidity, and ventilation cannot be controlled. The RRH cabinets are weather-hardened to operate under the environmental conditions listed in the table below. Condition Specification Operating temperature -40 °C to +46 °C (-40 °F to +115 °F) Extended operating temperature -40 °C to 50 °C (-40 °F to 122 °F) Relative humidity 5 to 100% (non-condensing but not to exceed 0.024 kg water/kg of dry air) Enclosure rating Type 3R (NEMA) IP35 (IEC 60529) Acoustic noise suppression 65 dBA at 25 °C (77 °F) at sea level Operating altitude -60.96 to 1798 m (-200 to 5,900 ft.) above sea level Extended operating altitude -60.96 to 3048 m (-200 to 10,000 ft.). An operating temperature de-rating of 1 °C per 1000 feet above 6000 feet is allowed Wind driven rain Refer to Telcordia GR-487-CORE Dust and water ingress Refer to Telcordia GR-487-CORE Bullet resistance Refer to Telcordia GR-487-CORE Wind resistance Refer to Telcordia GR-487-CORE Storage requirements Refer to Telcordia GR-63-CORE, Section 4.1.1 RRH heat dissipation The following table provides heat dissipation information for the various types of RRHs. RRH type Estimated DC heat dissipation [typical/maximum] 1900 MHz 750 watts 800 MHz 425 watts .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for RRHs RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Site requirements for RRHs General requirements The following general requirements must be met before the installation of the RRH can begin at the site: • Adequate clearance must be provided for service access. • • • Grounding electrode system must be installed. RF antenna runs must be installed . Tower light power must be installed (if required). • • Tower light alarm must be installed (if required). Cable supports must be installed. Refer to Appendix A, “9927 Distributed Base Station Outdoor Cabinet site preparation checklists” of this document for checklists of detailed requirements. Structural requirements Pole, wall loading, and wind must be considered during site preparation. In some cases, cell site equipment may not be mounted directly to a wall without a plate or Unistrut. A plate or Unistrut is necessary to properly distribute the weight of the RRHs. The support structure must be in compliance with national building and other applicable codes. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for RRH cabinet clearances RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... RRH cabinet clearances Minimum clearances table The following table provides the minimum wall mount clearances recommended around RRHs. Side of RRH cabinet Clearance in mm (inches) Comments Front 914 (36) Installation access Rear 50 (1.97) Zero rear clearance is allowed using supplied mounting brackets. Right 300 (11.82) Air flow Left 300 (11.82) Air flow Top 300 (11.82) Air flow Bottom 355 (14) Conduit routing Minimum clearances for wall mounted RRHs The following figure shows an example of typical distances between adjacent RRH cabinets. These clearances satisfy the minimum clearance requirements. RX 1 TX/RX 0 RX 1 TX/RX 0 RX 1 TX/RX 0 RRH RRH RRH To wall or obstruction 300 mm (11.82 in.) 300 mm (11.82 in.) 300 mm (11.82 in.) Cables provided by Alcatel-Lucent Hybriflex cable shall be provided by Alcatel-Lucent to connect the RRHs to the DC Distribution/Fiber Management Box. The Hybriflex cable contains fiber optic and DC power cables. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for RRH cabinet clearances RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Fiber optic cable shall be provided by Alcatel-Lucent to connect the 9927 Distributed BTS outdoor cabinet to the DC Distribution/Fiber Management Box. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for pole mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Site requirements for pole mount installations Prepare site for pole mounting installation The following are required to prepare a site for pole mounting installation of the cabinet. • • Install grounding system Install RF runs • • DC Distribution/Fiber Management Box provided by Alcatel-Lucent. Hybriflex cable provided by Alcatel-Lucent Pole mounting installation requirements The following table provides the specifications for the low profile pole mount. Low profile small pole mount specifications Standoff mm (inches) Application Pole diameter mm 40 (1.6) Single cabinet installation 50 -152 The following figure shows the pole brackets needed for small diameter poles (50 mm to 152 mm). Opposite bracket Pole bracket M10 nut 25 mm M10 hex bolt 300 mm M10 hex bolt Flatwasher Lockwasher .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for pole mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Pole mounting example The 800 MHz RRH and 1900 MHz, PCS, 4x40W RRH shall be mounted on a pole, as shown in the figure below. 1900 MHz,4x40W RRH .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for pole mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... The 800 MHz RRH and 1900 MHz, PCS, 4x45W RRH shall be mounted on a pole, as shown in the figure below. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for wall mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Site requirements for wall mount installations Overview This topic describes site requirements for installing RRHs on a wall. Prepare site for wall mount installation The following are required to prepare a site for wall mount installation of the cabinet. • • Install DC power runs Install grounding system • • • Install RF runs DC Distribution/Fiber Management Box provided by Alcatel-Lucent fiber cable Wall mounting shall comply with the applicable architectural codes listed on listed earlier in this chapter. Holes shall be pre-drilled with (customer supplied) anchor hardware, if mounting to a concrete wall. Unistruts shall be in place, if required for mounting cabinet. Cabinet wall mounting hardware The following is an example of customer-supplied mounting hardware that is required to mount struts to a solid concrete wall: • • 1.5 inch x 1.5 inch Unistrut® or equivalent struts (2) M10 (3/8 inch) x 100 mm (4inch) long Power-Stud™ (formerly called Rawl-Stud®) or equivalent anchor bolts for solid concrete walls (4) • • • • • M10 (3/8 inch) nuts (4) M10 (3/8 inch) flat washers (8) M10 (3/8 inch) spring nuts from the same manufacturer as the struts (4) M10 (3/8 inch) x 80 mm (1 inch) long hex-head bolts (4) M10 (3/8 inch) lock washers (4). .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for wall mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Wall mount hole pattern The figure below show how holes should be drilled in the wall for mounting the 800 MHz, 2x50W RRH, 1900 MHz, 4x40W (25 MHz) RRH and the 1900 MHz, 4x45W (65 MHz) RRH. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for wall mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... RRH Unistrut mounting hardware The following figure illustrates the hardware that is required to mount a Unistrut on a concrete wall and the cabinet to the Unistrut. Steps for installing Unistruts CAUTION Damage to equipment may result. Prior to drilling holes in a wall, consult with the customer as to the location of gas, water, and electrical pipes or conduits to minimize accidental hazard and equipment damage. Also consult with the building engineer as to local code requirements and wall loading information. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for wall mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Install the Unistruts as follows: ................................................................................................................................................................................................... Determine the layout of the struts that will support the cabinet. ................................................................................................................................................................................................... Place the top strut on the wall and make sure that the strut is level. Use the holes at the ends of the strut as a template to mark the positions of the holes to be drilled in the wall. ................................................................................................................................................................................................... Place the bottom strut against the wall [350 mm (13.8 inches) for 4x40W and 800 MHz RRHs] [515 mm for 4x45W 65 MHz RRH], measured center to center, from the top strut. Use the holes in the strut as a template to mark the positions of the holes to be drilled in the wall. See the figure below. ................................................................................................................................................................................................... Drill holes in the wall at the marked positions using an appropriate concrete drill bit for selected anchor. ................................................................................................................................................................................................... To install the top strut, place the top strut against the wall. Drive the anchor bolts into the holes of the strut until nut and washer are flush with the strut. ................................................................................................................................................................................................... Tighten the nut to proper torque requirement. ................................................................................................................................................................................................... Repeat Steps 5 and 6 to install the bottom strut. E................................................................................................................................................................................................... N D O F S T E P S .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-14 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for wall mount installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... RRH wall mount bracket assembly The following figure shows the completed installation of a wall mount bracket on a Unistrut assembly. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-15 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for floor stand installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Site requirements for floor stand installations Overview This topic describes site requirements for cabinet installation on a floor, such as the location and drilling of anchor holes for the floor stand. Anchor hole specifications for Floor Stand The following table provides anchoring specifications for floor stands installed in seismic zones 0 through 4. Seismic zone(s) Anchor type Number of holes Hole size mm (inches) Hole depth mm (inches) Torque Nm (lbf in) 0, 1, 2 1/2inch Dia drop-in 16 mm 50 mm 24 (212) (5/8 in.) (2 in.) M12 x 125 mm 18 mm 100 mm (11/16 in.) (4 in.) 3, 4 79 (700) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-16 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for floor stand installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... Floor stand The floor stand in the figure below is for installing an 800 MHz, 2x50W or 1900 MHz, 4x40W (25 MHz) RRH on a floor. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-17 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for floor stand installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... The figure below shows the anchor hole, drill pattern template for the floor stand. Mark and drill the anchor holes Important! The marking and drilling of the anchor holes shall be performed as part of site preparation. Anchor holes must be properly covered to prevent debris from falling inside. Before marking or drilling the anchor holes, refer toDrill anchor holes for more detail. Proceed as follows to mark and drill the anchor holes in a concrete surface: ................................................................................................................................................................................................... Measure and mark the location where the Floor Stand anchors will be installed. Refer to the above figure for anchoring footprint. ................................................................................................................................................................................................... Drill the anchor holes to the proper size and depth as specified in the previous table. Important! If a 100 mm (4.00 inch) hole depth cannot be attained for a 12-mm expansion stud anchor, a spacer may be removed from the anchor assembly when it is installed. The minimum depth of the hole is 76.2 mm (3.00”). .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-18 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for Site requirements for floor stand installations RRHs Site requirements for RRHs .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... If then floor stand is not available on site Tape over the open holes to prevent debris from falling inside. Do not install the anchors at this time. Anchors will be installed later by equipment installers. Procedure ends here. floor stand is available on site Continue with next step. ................................................................................................................................................................................................... Center floor stand over the drilled anchor holes. ................................................................................................................................................................................................... Set and torque the anchor bolts. E................................................................................................................................................................................................... N D O F S T E P S .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 6-19 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for RRHs Site requirements for floor stand installations .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 6-20 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 7 7 asic site preparation requirements and footprints for DC Distribution/Fiber Management Box ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 7-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Overview .................................................................................................................................................................................................................................... Overview Purpose This chapter describes basic site preparation requirements for the DC Distribution/Fiber Management Box, which interfaces the RRHs with the baseband cabinet. Two 1-1/2 inch liquid-tight flexible conduits enter the DC Distribution/Fiber Management Box from the baseband cabinet. One Hybriflex cable leaves the DC Distribution/Fiber Management Box and goes to the RRHs. Contents Cabinet clearances for DC Distribution/Fiber Management Box 7-3 Site requirements for wall mount installation of DC Distribution/Fiber Management Box 7-4 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 7-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Cabinet clearances for DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... Cabinet clearances for DC Distribution/Fiber Management Box Minimum clearances table The following table provides the minimum wall mount clearances recommended around the DC Distribution/Fiber Management Box. DC Clearances mm (inches) Distribution/Fiber Management Box Comments Front 914 (36) Installation access Rear 50 (1.97) Zero rear clearance is allowed using supplied mounting brackets. Right 152.4 (6) Installation access Left 152.4 (6) Installation access Top 152.4 (6) Installation access Bottom 304.8 (12) Conduit routing .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 7-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Site requirements for wall mount installation of DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... Site requirements for wall mount installation of DC Distribution/Fiber Management Box Overview This topic describes the requirements for installing the DC Distribution/Fiber Management Box on a wall. Prepare site for wall mount installation The following are required to prepare a site for wall mount installation of the DC Distribution/Fiber Management Box. • Install grounding system • Wall mounting Wall mounting shall comply with the applicable architectural codes listed earlier in this chapter. Holes shall be pre-drilled with (customer supplied) anchor hardware, if mounting to a concrete wall. Unistrut shall be in place, if it is required for mounting cabinet. Cabinet wall mounting hardware The following is a sample of customer-supplied mounting hardware that is required for mounting struts to a solid concrete wall: • • • • 1.5 inch x 1.5 inch Unistrut® or equivalent struts (2) M10 (3/8 inch) x 100 mm (4 inch) long Power-Stud™ (formerly called Rawl-Stud®) or equivalent anchor bolts for solid concrete walls (4) M10 (3/8 inch) nuts (4) M10 (3/8 inch) flat washers (8)* • • • M10 (3/8 inch) spring nuts from the same manufacturer as the struts (4) M10 (3/8 inch) x 25 mm (1 inch) long hex-head bolts (4) M10 (3/8 inch) lock washers (4). Location of DC Distribution/Fiber Management Box The DC Distribution/Fiber Management Box should be installed within a 25 foot conduit distance from the 9927 Distributed BTS outdoor cabinet. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 7-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Site requirements for wall mount installation of DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... Strut mounting hardware The following figure illustrates the hardware that is required to mount the strut on a concrete wall and the DC Distribution/Fiber Management Box to the strut. Steps to install Unistrut CAUTION Damage to equipment may result. Prior to drilling holes in a wall, consult with the customer as to the location of gas, water, and electrical pipes or conduits to minimize accidental hazard and equipment damage. Also consult with the building engineer as to local code requirements and wall loading information. Proceed as follows to install the Unistrut. ................................................................................................................................................................................................... Determine the layout of the struts that will support the cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 7-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Site requirements for wall mount installation of DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... Place the top strut on the wall and make sure that the strut is level. Use the holes at the ends of the strut as a template to mark the positions of the holes to be drilled in the wall. ................................................................................................................................................................................................... Place the bottom strut against the wall below the top strut according to the figure below. Use the holes in the strut as a template to mark the positions of the holes to be drilled in the wall. ................................................................................................................................................................................................... Drill holes in the wall at the marked positions using an appropriate concrete drill bit for selected anchor. ................................................................................................................................................................................................... To install the top strut, place the top strut against the wall. Drive the anchor bolts into the holes of the strut until nut and washer are flush with the strut. ................................................................................................................................................................................................... Tighten the nut to proper torque requirement. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 7-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Site requirements for wall mount installation of DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... Repeat Steps 5 and 6 to install the bottom strut. E................................................................................................................................................................................................... N D O F S T E P S Wall mount strut assembly The following figure shows a completed wall mount strut assembly. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 7-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Basic site preparation requirements and footprints for DC Distribution/Fiber Management Box Site requirements for wall mount installation of DC Distribution/Fiber Management Box .................................................................................................................................................................................................................................... DC Distribution/Fiber Management Box The following figure shows the back side of the DC Distribution/Fiber Management Box. There is a hole for a bolt in each corner of the DC Distribution/Fiber Management Box. The DC Distribution/Fiber Management Box is fastened to the wall with bolts via Unistruts. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 7-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 8 8lectrical power requirements for 9927 Distributed Base Station Outdoor Cabinet Overview Purpose This chapter provides AC electrical power requirements for the 9927 Distributed Base Station cabinets when installed at a new site. Contents Power overview 8-2 Power systems 8-3 Backup power systems 8-4 Electrical service requirements for 9927 Distributed Base Station outdoor cabinet 8-5 Power requirements for 9927 Distributed Base Station Outdoor Cabinet 8-6 General requirements 8-7 AC convenience outlet, AC PDA, and AC line surge protection 8-8 AC feeder cable and service panel requirements 8-10 Power requirements for new site installation of 9927 Distributed Base Station Outdoor Cabinet 8-11 Battery Reserve Times for batteries inside 60ECv2 battery cabinet 8-12 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Overview Station Outdoor Cabinet Power overview .................................................................................................................................................................................................................................... Power overview Overview Purpose This section provides an overview of the power requirements for 9927 Distributed Base Station Outdoor Cabinet. Contents Power systems 8-3 Backup power systems 8-4 Electrical service requirements for 9927 Distributed Base Station outdoor cabinet 8-5 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Power systems Station Outdoor Cabinet Power overview .................................................................................................................................................................................................................................... Power systems Integrated power The 9927 Distributed Base Station Outdoor Cabinet that is equipped with integrated power. A rectifier module converts site AC power to -48 VDC, which powers the cabinet. The rectifier module is located inside the cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Backup power systems Station Outdoor Cabinet Power overview .................................................................................................................................................................................................................................... Backup power systems About backup power The 9927 Distributed Base Station Outdoor Cabinet with integrated power requires a backup power system (a battery system) that can provide power to the cabinet in the event of a power failure. Battery backup options The following table provides battery backup options for the 9927 Distributed Base Station Outdoor Cabinet. The cabinet is not equipped with internal batteries. Battery options Description 60ECv2 battery cabinet Battery backup is provided by up to two 60ECv2 battery cabinets. Supported battery cabinets This topic describes the 60ECv2 battery cabinet. 60ECv2 battery cabinet The 60ECv2 Battery Cabinet provides -48 VDC battery backup for the 9927 Distributed Base Station Outdoor Cabinet. One or two 60ECv2 battery cabinets can be connected to the 9927 Distributed Base Station Outdoor Cabinet. The batteries are charged by the rectifier module inside the 9927 Distributed Base Station Outdoor Cabinet. Shelf heaters heat the batteries in cold weather. The shelf heaters are controlled by temperature sensors inside the battery cabinet. For information on how to install the 60ECv2 battery cabinet refer to the Installation Instructions Interface Kit for Standard Attachment of 60ECv2 Battery Cabinet to 9927 Distributed cabinets, CC 109-779-678. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Electrical service requirements for 9927 Distributed Base Station Outdoor Cabinet Station outdoor cabinet Power overview .................................................................................................................................................................................................................................... Electrical service requirements for 9927 Distributed Base Station outdoor cabinet Electrical service requirements for the 9927 Distributed Base Station Outdoor Cabinet The electrical service requirements for the 9927 Distributed Base Station Outdoor Cabinet are listed on the cabinet nameplate. They are as follows: • 120/208 VAC, 120/240 VAC, 3 wire + Gnd, 80 A, 50/60 Hz .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Overview Station Outdoor Cabinet Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet Power requirements for 9927 Distributed Base Station Outdoor Cabinet Overview Purpose This section describes the power requirements for the 9927 Distributed Base Station Outdoor Cabinet. Contents General requirements 8-7 AC convenience outlet, AC PDA, and AC line surge protection 8-8 AC feeder cable and service panel requirements 8-10 Power requirements for new site installation of 9927 Distributed Base Station Outdoor Cabinet 8-11 Battery Reserve Times for batteries inside 60ECv2 battery cabinet 8-12 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base General requirements Station Outdoor Cabinet Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet General requirements Purpose This section describes the AC power requirements for the Alcatel-Lucent equipment at the site. AC power requirements AC power must also be provided for lighting, AC convenience outlets, and any additional AC-powered equipment that will be present at the site. The appropriate product information must be consulted to determine the total AC power required for the equipment at the site. As part of site preparation, the site must be equipped with an appropriate AC service panel board or AC branch circuit load center for supplying power to the AC equipment at the site. All AC power wiring, distribution, and protection equipment must be installed during site preparation. The site must be ready to accept installation of the 9927 Distributed Base Station Outdoor Cabinet. CAUTION Personnel Safety and/or Electrical Damage to Equipment All AC wiring and over-current protection must be installed in accordance with the National Electric Code (NFPA-70), the Canadian Electrical Code, Part 1 (CSA C22.1) or the local electrical code in effect. An appropriate equipment ground connection is required before commercial AC service can be connected to any equipment at the site. Conduit requirements A rigid conduit for AC power supply conduit is required. It is the responsibility of the customer to provide the rigid conduit and install it as part of site preparation. A flexible conduit for AC is also required. It is the responsibility of the customer to purchase the flexible conduits as part of site preparation, and hold them for the installer, who will install them during installation. See “Conduit requirements” (p. 5-7) for specifications for the required conduits. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base AC convenience outlet, AC PDA, and AC line surge Station Outdoor Cabinet protection Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet AC convenience outlet, AC PDA, and AC line surge protection AC convenience outlet Cell sites must be equipped with at least one duplex AC convenience outlet, which is needed for installation and maintenance procedures. The outlet is required to power test equipment and installation tools. The duplex outlet must be protected in accordance with national and local electrical codes. An outlet must be installed within 1.5 meters (5 feet) of the 9927 Distributed Base Station cabinets. Ground Fault Circuit Interrupters (GFCI) or Residual Current Devices (RCD), used in non-North American type installations, are recommended and must be used where required by code. For NAR installations, this AC convenience outlet is provided in the 9927 Distributed Base Station Outdoor Cabinet. There is no need for the customer to provide an additional AC convenience outlet at the site. AC PDA The AC Power Distribution Assembly (AC PDA) is inside the 9927 Distributed Base Station cabinet with integrated power. AC power to the 9927 Distributed Base Station Outdoor Cabinet must be supplied from an external AC service panel board or branch circuit load center capable of supplying a two-pole single-phase circuit to power the 9927 Distributed Base Station Outdoor Cabinet at the site. The AC PDA is equipped with a terminal block rail populated with “strip and poke” terminals for connection of the AC input conductors and the equipment grounding conductor. The terminals are configured for either North American 120/240 V, 3-wire single-phase connections, 120/208 V, 3-wire single-phase connections, or for single-phase 230 V (line-to-neutral) connections used in other locations around the globe. When a North American NEMA 15A-240V duplexed AC convenience outlet is equipped, a terminal is provided for the connection of the neutral conductor for this outlet. The AC PDA in the 9927 Distributed Base Station cabinet can only be used for distributing AC power to Alcatel-Lucent equipment. AC line surge protection Important! The 9927 Distributed Base Station Outdoor Cabinet is not equipped with AC line surge protection. AC line surge protection is required at the site's main AC panel. A surge protection device capable of discharging the surge waveforms as defined in IEEE C62.41 (1991), Recommended Practice on Surge Voltage in Low-Voltage AC Power Circuits, for Location Category "C3" and "High System Exposure" must be installed in the AC panel board or load center supplying AC power to the power cabinet and/or basestand frame with integrated power. The AC panel board or load center, surge .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base AC convenience outlet, AC PDA, and AC line surge Station Outdoor Cabinet protection Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet protector, and AC wires from the service panel to the applicable cabinet, are not supplied with the power cabinet. They must be procured and installed as part of site preparation. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base AC feeder cable and service panel requirements Station Outdoor Cabinet Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet AC feeder cable and service panel requirements AC power requirements The 9927 Distributed Base Station cabinet requires a single-phase branch circuit from an external service panel. The service panel must be installed during site preparation. AC feeder cable and service panel requirements for a fully configured system (North American installation) For a fully configured system, the AC panel must be rated at 100 A. If additional AC equipment is installed at the site, the total power consumption for all site equipment must not exceed the service rating. The AC power feeders are class B stranded, insulated cable with THHN type insulation (T90 NYLON type insulation in Canada). The installation should not be performed in extremely cold temperatures (-15 °C / -5 °F or less). The following table provides AC input requirements for a fully configured system with 100-A service panel (North American installation). The following table provides the recommended wire sizes. 9927 Distributed Base Station Component Rating/Gauge Circuit breaker 100 Amp, 2 pole Wire for L1 and L2 42.4 mm2 (1 AWG) 1 Neutral wire 8.4 mm2 (8 AWG) 2 Equipment grounding conductor 8.4 mm2 (8 AWG) 2 Notes: 1. 27 mm2 (3-AWG) wire may be used if the terminals on each end of the input conductors are marked “75° C.” The AC input terminal block in the 9927 cabinet is rated at 75° C. 2. In Canada, 13.3 mm2 (6 AWG) wire is required for telecommunications primary protector grounding. Supplementary ground conductors, sized between 13.3 mm2 (6 AWG) and 33.6 mm2 (2-AWG) are provided with this equipment. Refer to “Grounding electrode system” (p. 12-6). .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Power requirements for new site installation of 9927 Station Outdoor Cabinet Distributed Base Station Outdoor Cabinet Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet Power requirements for new site installation of 9927 Distributed Base Station Outdoor Cabinet How to determine power requirements for 9927 Distributed Base Station Outdoor Cabinet The primary source for power requirements is Engineering Rules for Factory and Field Installation Kits for 9927 Distributed Base Station, ER_0105_0006. How to calculate power requirements for different 9927 Distributed Base Station Outdoor Cabinet configurations The typical and maximum DC power requirement and number of rectifiers required for various 9927 Distributed Base Station Outdoor Cabinet configurations are provided in Engineering Rules for Factory and Field Installation Kits for 9927 Distributed Base Station, ER_0105_0006. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 8-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for 9927 Distributed Base Battery Reserve Times for batteries inside 60ECv2 battery Station Outdoor Cabinet cabinet Power requirements for 9927 Distributed Base Station .................................................................................................................................................................................................................................... Outdoor Cabinet Battery Reserve Times for batteries inside 60ECv2 battery cabinet Battery Reserve Times for battery strings inside 60ECv2 battery cabinet The table below lists the Battery Reserve Times for 12IR145 battery strings inside the 60ECv2 battery cabinet. Various numbers of battery strings are connected in parallel. The provided values are for battery strings powering a 10,500 watt load. One battery string consists of two 12IR145 (145 Ah) batteries connected in series. Battery Reserve Times for battery strings inside 60ECv2 battery cabinet powering 10,500 watt load (One string = Two 12IR145 (145 Ah) batteries connected in series) Number of battery strings connected in parallel 10 12 14 Battery Reserve Time (Hours) 0.8 1.9 3.2 4.6 6.1 7.7 9.4 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 8-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9 9lectrical power requirements for RRHs Overview Purpose This chapter provides guidelines for running electrical power to the RRHs, when the RRHs are up to 15 m from the 9927 Distributed Base Station Outdoor Cabinet. Contents Power requirements (general) 9-2 Power consumption 9-3 DC power requirements for RRHs 9-4 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 9-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for RRHs Power requirements (general) .................................................................................................................................................................................................................................... Power requirements (general) General requirements This section provides the DC power requirements for the RRHs. Electrical power requirements for RRHs The electrical power requirements for the RRHs, at full rated output power, are as follows. RRH Full rated output power at -48 VDC 1900 MHz, 4x40 W 690 Watts, 15 Amps 1900 MHz, 4x45 W 750 Watts, 17 Amps 800 MHz, 2x50 W 450 Watts, 9.0 Amps .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 9-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Electrical power requirements for RRHs Power consumption .................................................................................................................................................................................................................................... Power consumption General This section provides input power requirements for RRHs. The term "typical" implies the site is operating with "busy hour" traffic and at normal room temperatures, with the batteries on float charge. End-of-life battery reserve times are typically 80% of the initial battery capacity. The maximum levels in the table represent expected maximum load when the heater in the RRH is turned on. Power consumption for RRHs The table below lists the power consumption values for the two types of RRHs. Power Consumption for RRHs RRH type Power Draw Typical (watts) 1900 MHz, PCS, 4x40W (25 MHz) 655 1900 MHz, PCS, 4x45W (65 MHz) 715 800 MHz, 2x50W 425 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 9-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Electrical power requirements for RRHs DC power requirements for RRHs .................................................................................................................................................................................................................................... DC power requirements for RRHs DC feeders between 9927 Distributed Base Station Outdoor Cabinet and RRHs The DC feeder cable, from the 9927 Distributed BTS outdoor cabinet to the DC Distribution/Fiber Management Box, is routed in flexible metallic conduit. Hybriflex cable is routed from the DC Distribution/Fiber Management Box to the RRHs. The Hybriflex cable contains four 8 AWG feeders for the RRHs. The following table lists the circuit breaker size, wire gauge, and maximum length for copper DC feeders from the 9927 Distributed BTS outdoor cabinet to the DC Distribution/Fiber Management Box. DC feeders from 9927 Distributed BTS outdoor cabinet to DC Distribution/Fiber Management Box Voltage DC, Nominal –48 VDC Feeders 1 and 2 Circuit Breaker (AMPS) Wire Gauge Max. Length 90 35 mm² (2 AWG) 10.7 m (35 feet) The table below lists the wire gauges for various maximum lengths of copper DC feeder cable from the DC Distribution/Fiber Management Box to the RRHs. DC feeders from DC Distribution/Fiber Management Box to RRHs Max Length Wire Gauge (AWG) Max Power (watts) RRH Type 380 450 2x50 240 450 2x50 150 10 450 2x50 400 690 4x40 250 690 4x40 160 690 4x40 100 10 690 4x40 4x45 4x45 4x45 4x45 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 9-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 10 10 preparation Site requirements for 9927 Distributed Base Station Outdoor cabinet GPS antenna and microwave antenna cable ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 10-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Overview Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... Overview Purpose This chapter discusses site preparation requirements for GPS and microwave antennas at the 9927 Distributed Base Station Outdoor Cabinet. Contents General requirements 10-3 Site preparation for GPS antenna 10-4 Site preparation for microwave antenna cables 10-6 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 10-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base General requirements Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... General requirements Introduction This section describes site preparation guidelines for the GPS antenna. Requirements The following are general requirements for the GPS antenna. • • All materials for outdoor antenna cables must be rated for outdoor use. Alcatel-Lucent recommended antenna jumper cables, or equivalent, must be used. • All antenna cable runs must be appropriately supported, in accordance to the connector and cable manufacturer's instructions. Antenna and cable sweeps must be made before start of installation. • .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 10-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Site preparation for GPS antenna Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... Site preparation for GPS antenna Introduction This section describes how to perform site preparation for the GPS antenna. Connection overview for GPS antenna The GPS antenna is a receive-only antenna that requires only one antenna run. The GPS antenna cable is terminated at the antenna support structure with a 7/16 DIN female connector. At the antenna it is terminated with a 7/16 DIN-male connector. A gas tube surge protector with DIN male/female connectors must also be installed. A jumper cable connects the GPS antenna surge protector to the GPS antenna connector on the 9927 Distributed Base Station Outdoor Cabinet. GPS cable connectors and surge protectors must be rated IP-67 or better. (IP-67 rating requirement, as defined in IEC 60529, specifies total protection against dust and protection against submersion in water.) A side view of the GPS antenna connections are shown in the following diagram. 7/16 DIN-Male Connector on Jumper Cable *Surge Protector at GPS port Surge Protector Antenna cable support Coaxial Cable Shield Grounding 9927 Distributed BTS To Antenna Tower Jumper Cable Ground * BB (See Note) Antenna Cable Ground Drip loop 7/16 DIN-Male Connector on Jumper Cable 7/16 DIN-Female Connector On Antenna Cable * GPS jumper cable and field installed surge protector to 9927 Distributed BTS outdoor cabinet GPS port (1 place) Recommended GPS antenna cable Important! The recommended cable type should be outdoor (UV) and riser (fire retardant) rated. The following table provides information for the recommended GPS antenna cable type. Product Specification Manufacturer (Reference) Cable P/N (Reference) WP-93807 L3 OEM1 LDF4-RN-50A .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 10-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Site preparation for GPS antenna Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... Surge protection for GPS antenna jumper cables Surge protectors are required for the GPS antenna. Gas tube surge protectors are used, and must be installed as part of site preparation. Antenna shield grounding for GPS antenna jumper cables The GPS antenna cable coaxial cable shield shall be bonded at least at one point close to the equipment, providing the GPS antenna is installed in the cone of protection with short (shorter than 60 foot) coaxial cable. Grounding of the antenna cable outer shield must be performed in accordance with the ground kit manufacturer's instructions, as outlined in Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115. GPS antenna cable lengths The following table provides GPS antenna cable lengths information for various configurations. Cable type GPS antenna gain (dB) Maximum cable length m (feet) LDF4 26 75 (245) Notes: 1. Cable lengths are based on typical applications. Cable length includes antenna and jumper cable. Verify GPS antenna installation It is recommended that a Garmin 45XL (or equivalent) GPS should be used to verify GPS antenna installation and line-of-site before installing the 9927 Distributed Base Station Outdoor Cabinet. For detailed GPS antenna installation instructions, refer to Appendix E, “GPS antenna installation”. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 10-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Site preparation for microwave antenna cables Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... Site preparation for microwave antenna cables Introduction This section discusses how to prepare the microwave antenna cables so can be connected to the 9927 Distributed Base Station Outdoor Cabinet. Connection overview for microwave antenna cables The microwave cable is supplied by the customer. It will be routed and connected to the 9927 Distributed Base Station Outdoor Cabinet at a later date. There can be up to 16 microwave cables (4 sets of 4–pack cables) entering the top-rear of the 9927 Distributed Base Station Outdoor Cabinet. In site preparation, approximately 10 feet of each microwave cable must be coiled about six feet from the top-rear of the cabinet. Each microwave cable is terminated with an RJ-45 connector and must be connected to the appropriate injector module inside the 9927 Distributed Base Station Outdoor Cabinet. Label each end microwave cable During site preparation, it is the customer's responsibility to label the end of each microwave cable so that the installer can easily identify each cable and connect it properly at installation. Label each microwave cable at the baseband cabinet end as follows: Microwave Ant 1, Microwave Ant 2, Microwave Ant 3, etc. Recommended microwave antenna cable Important! The recommended cable type is outdoor (UV) as well as riser (fire retardant) rated. The recommended cable is Nexans SF/UTP CAT5E 4PR in&Out . The following table provides information for the recommended microwave antenna cable type. Product Specification Manufacturer (Reference) Product Family (Reference) Indoor/Outdoor cable suitable for: Nexans LAN CAT5E 4PR In&Out • Fast Ethernet IEC 61156 • Gagabit Ethernet ISO/IEC 11801 • Power over Ethernet .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 10-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Site preparation for microwave antenna cables Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... Antenna shield grounding for microwave antenna jumper cables The microwave antenna cable shield shall be bonded every _________ feet. Grounding of the antenna cable outer shield must be performed in accordance with the ground kit manufacturer's instructions, as outlined in Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 10-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation requirements for 9927 Distributed Base Site preparation for microwave antenna cables Station Outdoor cabinet GPS antenna and microwave antenna cable .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 10-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 11 11 antenna cable RF requirements for RRHs Overview Purpose This chapter provides an overview of RF antenna interface requirements for RRHs. Contents Antenna requirements 11-2 Surge protection requirements 11-3 General antenna cable requirements 11-4 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 11-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 RF antenna cable requirements for RRHs Antenna requirements .................................................................................................................................................................................................................................... Antenna requirements General requirements The customer can order 1/2 inch coaxial jumper cable to interface the RRH with the antenna. It is the customer's responseability to arrange for the construction of the RF path. This includes providing for grounding, surge protection and construction of the support structure. Constraints on the antenna position In order to support location-based services, all antennas that serve a sector must be within a circle no more than 15 m in diameter. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 11-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 RF antenna cable requirements for RRHs Surge protection requirements .................................................................................................................................................................................................................................... Surge protection requirements General requirements The RF Filter inside the RRH is already equipped with a surge protector. RF surge protection is not required for standard star configurations (one RRH per sector). .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 11-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 RF antenna cable requirements for RRHs General antenna cable requirements .................................................................................................................................................................................................................................... General antenna cable requirements General requirements All cable runs must be supported appropriately, in accordance with connector and cable manufacturer's instructions. The appropriate type, length, and number of antenna jumper cables should be available at the site when starting installation. Grounding of the antenna feeder cable outer shield must be performed in accordance with the manufacturer's grounding kit instructions. The following are general antenna requirements: • • • Alcatel-Lucent recommended antenna cables should be used. All antenna cable runs must be appropriately supported in accordance with the connector and cable manufacturer instructions. All antenna connectors must be rated IP-67 or better. Important! All RF connectors must be at least IP67 rated. (IP67 rating requirement, as defined by IEC 60529, calls for total protection against dust and protection against submersion in water.) Antenna installation Antenna installations shall be performed in accordance with all applicable manufacturer's recommendations, and national laws and regulations. To ensure correct antenna installation, all necessary calculations and/or field measurements shall be evaluated for compliance with applicable national laws or regulations regarding exposure to electromagnetic fields. The antenna manufacturer or supplier shall deliver all technical data necessary to perform this compliance evaluation (e.g., antenna gain pattern, antenna dimensions, etc.). Information about methodology and results of compliance evaluation shall be available for inspection by officials of governing authorities. Antenna cable grounding Grounding of the antenna cable outer shield must be performed in accordance with the ground kit manufacturer's instructions, as outlined in Grounding and Lightning Protection Guidelines for Wireless System Cell Sites, 401-200-115. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 11-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 RF antenna cable requirements for RRHs General antenna cable requirements .................................................................................................................................................................................................................................... The following figure shows a typical method for connecting an antenna cable. CABLE GROUND KIT ANTENNA CABLE #6 AWG STRANDED INSULATED COPPER GROUND WIRE DOUBLE HOLE LUG TO BUS BAR RF antenna connections The RRH accepts two RF antenna cables on top of the unit. The connectors are 7/16 DIN. One 7/16 DIN connector is for Tx/Rx, the other is Rx-only. An external RF surge protector is not required. RF antenna cable requirements The RRH can support up to two RF antennas per one-sector configuration with transmit/receive diversity. The RF antenna cable must satisfy the following requirements: • • Impedance: 50 ohms Attenuation: < 3 dB • • • Antenna jumper cable at the baseband cabinet end must be equipped with a 7-16 DIN center pin straight male connector. Surge protection (not required for outdoor) properly grounded. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 11-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 RF antenna cable requirements for RRHs General antenna cable requirements .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 11-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 12 12 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Overview Purpose This chapter provides information on grounding and lightning protection requirements for a 9927 Distributed Base Station Outdoor Cabinet site. Contents Grounding requirements 12-2 Surge protection requirements 12-3 Grounding electrode system 12-6 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 12-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Grounding requirements .................................................................................................................................................................................................................................... Grounding requirements General requirements The 9927 Distributed Base Station Outdoor Cabinet must be grounded by means of an integrated (multipoint) grounding system. The equipment is susceptible to lightning surges because it is associated with towers and antennas. It is therefore imperative that the cell site be properly grounded and that a low impedance path to earth be provided. The grounding conductors must be as straight and short as possible. No sharp bends or loops are permitted for grounding conductors. NOTICE Equipment Warranty The equipment warranty can be voided if the guidelines in the National Electrical Code (NFPA 70), the Canadian Electrical Code, Part 1 (CSA C22.1), or the local code in effect, as well as the Standard for Installation of Lighting Protection Systems (NFPA 780, latest edition), and Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115 are not followed. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 12-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Surge protection requirements .................................................................................................................................................................................................................................... Surge protection requirements General surge protection requirements Commercial AC power and T1/E1 facilities are susceptible to lightning surges and must be properly protected. An appropriate surge protection device must be installed at the service entry point and be connected directly to the grounding electrode system. The GPS antenna coaxial cables are also susceptible to lightning surges and must be protected. As part of site preparation, a surge protection device must be installed between each antenna coaxial cable and jumper cable, approximately 1 meter (3 ft.) away from the equipment. They can be obtained from Alcatel-Lucent (KS24577, L-3A for GPS and KS24577, L-4A for RF), or an Alcatel-Lucent-approved equivalent can be used. The surge protectors must be bonded to a nearby ground bus bar that is connected directly to the grounding electrode system at two points. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 12-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Surge protection requirements .................................................................................................................................................................................................................................... Diagram of a typical surge protector installation The following diagram shows a typical surge protector installation. SURGE PROTECTOR DETAIL DIN MALE ANTENNA CABLE DIN FEMALE JUMPER CABLE SURGE PROTECTION DEVICE (GAS TUBE PROTECTOR) DIN FEMALE DIN MALE COAXIAL CABLE SHIELD GROUNDING TO ANTENNA JUMPER TO CABINET #6 AWG STRANDED INSULATED COPPER WIRE (INSULATION TO BE UV RESISTENT) FOR GROUNDING SUPPORT STRUCTURE #6 AWG STRANDED INSULATED COPPER WIRE FOR GROUNDING SURGE PROTECTION DEVICE (INSULATION TO BE UV RESISTANT) BUS BARS #2 AWG BARE SOLID TINNED COPPER WIRE TO GROUNDING ELECTRODE SYSTEM Ground Ground Antenna cable shield grounding for GPS antenna The tower or metallic support for the antenna must also be bonded to the grounding electrode system. The GPS antenna coaxial cable shield shall also be bonded at one point (minimum), near the equipment, before entering a building, provided the GPS antenna is installed in Zone of protection with short (60 feet / 18 meters or less) coaxial cable. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 12-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Surge protection requirements .................................................................................................................................................................................................................................... Important! If the coaxial run along the tower is more than 60 feet / 18 meters, then the coaxial cable shields to be grounded at multiple points near the antenna and equipment at 100 foot (30 meter) intervals. The following diagram shows a typical method for grounding an antenna cable outer shield. CABLE GROUND KIT ANTENNA CABLE #6 AWG STRANDED INSULATED COPPER GROUND WIRE DOUBLE HOLE LUG TO BUS BAR .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 12-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Grounding electrode system .................................................................................................................................................................................................................................... Grounding electrode system Grounding electrode system requirements 9927 Distributed Base Station Outdoor Cabinet sites must be equipped with a grounding electrode system (that is, buried ring ground, copper clad rod, electrolytic rods, metallic water pipe, etc.). The cell site grounding, including all cabinets and antenna cable shields, must be bonded to the grounding electrode system. The grounding electrode system shall be installed as part of site preparation with a sufficient number of pigtails. Electrically conductive materials in the vicinity that are likely to become energized must be connected together and to the grounding electrode system in a manner that establishes an effective ground-fault current path. Buried ground conductors must be, at a minimum, 33.6 mm2 (2 AWG) bare, solid, tinned copper wire. Exterior ground conductors must be, at a minimum, 33.6 mm2 (2 AWG) either solid, bare, tinned copper or stranded, insulated (outdoor insulation to be sunlight-resistant) copper cable. Exothermic weld Exothermic weld is recommended for grounding connections where practical. All below-grade connections must be exothermically welded. Compression type, two-hole (0.75-inch center) lugs or double crimp “C” taps are acceptable for above-ground connections. The contact area where connections are made shall be prepared to a bare bright finish, and be coated with an anti-oxidation material before connections are made. Important! All grounding system material (cable, connectors, buses, etc.) must be of high quality materials that resist deterioration and require little or no maintenance. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 12-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Grounding electrode system .................................................................................................................................................................................................................................... Typical grounding configuration (concrete pad) The following diagram shows the typical grounding configuration for a 9927 Distributed Base Station Outdoor Cabinet site on a concrete pad. Surge Protection Device .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 12-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for 9927 Distributed Base Station Outdoor Cabinet Grounding electrode system .................................................................................................................................................................................................................................... Typical grounding configuration (rooftop) The following diagram shows the typical grounding configuration for a 9927 Distributed Base Station Outdoor Cabinet site on a rooftop. Surge Protection Device .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 12-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 13 13 Grounding and lightning protection requirements for RRHs Overview Purpose This chapter discusses grounding and lightning protection requirements for the RRHs. Contents Grounding and surge protection requirements 13-2 Grounding examples - Remote Radio Head 13-3 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 13-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for RRHs Grounding and surge protection requirements .................................................................................................................................................................................................................................... Grounding and surge protection requirements Surge protection in RRHs The RRHs are equipped with internal surge protectors. No external surge protectors are required. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 13-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Grounding and lightning protection requirements for RRHs Grounding examples - Remote Radio Head .................................................................................................................................................................................................................................... Grounding examples - Remote Radio Head Wall mount grounding Each RRH cabinet must be grounded. The RRH cabinet must be grounded as follows: 1. At the top of cabinet 2. At the right side of cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 13-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for RRHs Grounding examples - Remote Radio Head .................................................................................................................................................................................................................................... The figure shows how 6 AWG ground cable can be routed from a wall mounted RRH to the system ground. To system grounding 2 AWG to 2 AWG 35 mm (2 AWG) 35 mm (2 AWG) See Important! Note Surge protector for antenna sharing #6 AWG ground cable 2 AWG to 2 AWG 6 ft max distance Ground bus bar To system Grounding electrode/ ground rod Important! In order to connect an antenna sharing surge protector to ground, a grounding bus bar must be installed within 6 feet of RRHs. This applies to antenna sharing/daisy chain installations (two RRHs per sector). .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 13-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Grounding and lightning protection requirements for RRHs Grounding examples - Remote Radio Head .................................................................................................................................................................................................................................... Pole mount grounding Each RRH cabinet must be grounded. Each RRH cabinet must be grounded as follows: • • At the top of the cabinet At the left or right side of the cabinet. The figure below shows how 2 AWG ground cable can be routed, along the pole, from the RRH to the ground rod. 35 mm2 (2 AWG) 2 AWG to 2 AWG 35 mm2 (2 AWG) 2 AWG to 2 AWG See Important! Note Surge protector for antenna sharing #6 AWG ground cable 35 mm2 (2 AWG) 6 ft max distance Ground bus bar To grounding electrode/ ground rod Important! For antenna sharing/daisy chain installations (two RRHs per sector), a grounding bus bar must be installed within 6 feet of the RRHs, to ground the antenna sharing surge protector. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 13-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Grounding and lightning protection requirements for RRHs Grounding examples - Remote Radio Head .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 13-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 14 14 preparation -- T1/E1 Site and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Overview Purpose This chapter describes the site preparation requirements related to T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet. Contents Balun Block requirements 14-2 Site preparation for T1/E1 and User Alarm cables 14-3 Specify assignments for T1/E1 lines 14-6 Site preparation for User Alarm cables 14-9 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Balun Block requirements .................................................................................................................................................................................................................................... Balun Block requirements Overview The customer is responsible to convert the 75 ohm unbalanced coaxial cable to 120 ohm balanced twisted pairs. The conversion of the coaxial cable to twisted pairs may be accomplished with Alcatel-Lucent balun or equivalent. Important! The customer shall provide primary protection and the appropriate hardware to mount and ground the Balun Block. T1/E1 Input Lines (From service provider) NIU with primary protection (Provided as part of site prep.) T1/E1 lines to Balun Block Balun Block (Coaxial cable) Note 1 T1/E1 Cable (See Note 2) To 9927 Distributed BTS Outdoor Cabinet Maximum distance = 10 m (35 feet) NOTE 1: The Balun Block must be located within a 10 m (35 foot) cable length distance from the radio cabinet. NOTE 2: RJ-45 connectors must be installed on T1/E1 cables before T1/E1 cables can be connected to a Balun Block. There can be up to two T1/E1 cables. Each T1/E1 cable contains 24 twisted-wire pairs. Three branch cables can go to a Balun Block. Each branch cable contains 8 twisted-wire pairs. Each balun block accepts 8 twisted-wire pairs or 4 T1 lines. Each T1 line contains 2 twisted-wire pairs. Therefore, a cable with 24 twisted-wire pairs contains 12 T1 lines and requires 3 Balun Blocks. A second 24 twisted-wire pair cable is required for a 9927 Distributed BTS Outdoor Cabinet populated with URC-IIIs (which allow up to 20 lines). In this case, 16 of the 24 twisted-wire pairs would be used. Refer to Balun Blocks #4 and #5 in the following table. Balun Block connections Important! The Balun Block must be installed within 10 m (35 feet) of the 9927 cabinet. The T1/E1 cable will be connected directly to the Balun Block. Four RJ-45 loose connectors will be provided with each Balun Block. The RJ-45 connectors will be connected to T1/E1 cables during installation of the 9927 Distributed Base Station Outdoor cabinet. An RJ-45 connector crimping tool is needed to connect RJ-45 connectors to T1/E1 cable twisted-wire pairs. The part number for the RJ-45 connector crimping tool is R-5520. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for T1/E1 and User Alarm cables .................................................................................................................................................................................................................................... Site preparation for T1/E1 and User Alarm cables Purpose This section describes how to perform site preparation for T1/E1 and User Alarm cables. T1/E1 and User Alarm cables are both twisted-pair cables that are connected on one side to the Network Interface Unit (NIU) and on the other side to the 9927 Distributed Base Station Outdoor Cabinet. The site preparation for T1/E1 and User Alarm cables is performed at the same time. Connection overview for T1/E1 and User Alarm cables The following diagram shows the installation of the twisted-pair cable from the NIU to the EFIM inside the 9927 Distributed Base Station Outdoor Cabinet. Flexible T1/E1 Conduit T1/E1 CABLE (twisted-pair cable within conduits) BALUN BLOCK BOX AND CONNECTOR (if required) CUSTOMER-SUPPLIED PROTECTION DEVICE M5PM (supplied w/ cabinet) Rigid NIU Conduit 6 AWG STRANDED INSULATED GROUND WIRE CROSS-CONNECT BLOCK TELEPHONE SERVICE 9927 DISTRIBUTED BTS OUTDOOR CABINET 6 AWG GROUND WIRE (TYP) NETWORK INTERFACE UNIT (supplied and installed as part of site preparation) Number of T1/E1 cables The number of T1/E1 cables, which can be connected to a 9927 Distributed Base Station cabinet varies depending upon the number of SEC-B installed in the cabinet. Four T1/E1 lines go to each SEC-B. Number of User Alarm cables The 9927 Distributed BTS is equipped with an M5PM alarm module, which can accept up o 32 User Alarms. One alarm cable supports 16 alarms. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for T1/E1 and User Alarm cables .................................................................................................................................................................................................................................... Connect T1/E1 cables and User Alarm cables to NIU The T1/E1 and User Alarm facilities must be in place prior to installation of the 9927 Distributed Base Station Outdoor Cabinet. The service provider usually supplies a carbon or gas tube protector for the T1/E1 facility. The 9927 Distributed Base Station Outdoor Cabinet is already equipped with Listed primary surge protection. If required, a Balun Block must also be installed to balance the impedance of the coaxial cable with the impedance of the twisted-wire pairs at the Network Interface Unit (NIU). The required twisted-pair cable must be supplied and connected to the T1/E1 facility at the NIU, as part of site preparation. Sufficient cable length must be coiled to allow for future connection to the Enhanced Facility Interface Module (EFIM) inside the 9927 Distributed Base Station Outdoor Cabinet. The appropriate number of T1/E1 cables must be available at the site prior to installation. Important! In the United States, refer to Article 800 of the National Electrical Code, NFPA 70, for selection and installation of the primary protector. In Canada, refer to Section 60 of the Canadian Electrical Code, Part 1, CSA C22.1 for selection and installation of the primary protector. For international applications, refer to ITU K.11, “Principles of Protection Against Over-voltages and Over-currents.” Important! Unused or spare T1/E1 cables at the NIU must not be looped back towards the 9927 Distributed Base Station Outdoor Cabinet while the cabinet is in operation. The twisted-pair cable must be installed in a dry location with minimal humidity. The installation must not be performed in extremely cold temperatures [-15 °C (5 °F) or less] (see “Minimum installation temperatures” (p. 5-4)). It is recommended that the T1/E1 cable shield be bonded at the end that connects to the NIU. Install rigid NIU conduit and flexible T1/E1 conduit This topic describes the conduits required for T1/E1 and User Alarm cables. T1/E1 and User Alarm cables are routed through the conduits that are already in place for the 9927 Distributed Base Station cabinet. Rigid NIU conduit is required to bring T1/E1 and User Alarm cables to the site. It is the customer's responsibility to provide rigid conduit and all required connectors and fittings. The customer must also install these in site preparation. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for T1/E1 and User Alarm cables .................................................................................................................................................................................................................................... The recommendations for NIU conduit are as follows: • • The rigid NIU conduit must be installed from the NIU to the 9927 Distributed Base Station Outdoor Cabinet. Use PVC conduit instead of rigid NIU conduit if it is to be buried. Use metal conduit if it is to be exposed. The NIU end of the conduit must be bonded if it is metallic. Flexible T1/E1 conduit is also required. It is the responsibility of the customer to provide flexible conduit and all required connectors and fittings, and to hold them for the installer. See “Conduit requirements” (p. 5-7) for specifications for the required conduits. Route the T1/E1 and User Alarm cables through the conduits After the T1/E1 and User Alarm cables have been connected to the NIU, and the conduits have been installed, the T1/E1 and User Alarm cables must be routed through the NIU conduit, and coiled approximately 6 meters (20 ft.) at the end of the conduit. To prevent damage to the twisted-pair cable inside the conduit, the conduit end must be properly protected against the environment, rodents, and other interferences. This can be done by stuffing the twisted-pair cable into the conduit, and capping the end of the conduit. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Specify assignments for T1/E1 lines .................................................................................................................................................................................................................................... Specify assignments for T1/E1 lines Purpose This section describes how to determine the T1/E1 line assignments for T1/E1 cables, and record them in a table that will be used during installation. T1/E1 line assignments for 9927 Distributed Base Station Outdoor Cabinet with SEC-B (20 T1/E1 lines, maximum) The following table provides the installer with T1/E1 line assignments for 9927 Distributed Base Station Outdoor Cabinet with four SEC-Bs. Because each SEC-B supports four T1/E1 lines, the cabinet can support up to 16 T1/E1 lines. The table below must be completed as part of site preparation. SEC-B T1/E1 Line # Function Tx/Rx RJ-45 Pinout # Wire Color Rx ____-T White-Orange Rx ____-R Orange-White Tx ____-T White-Blue Tx ____-R Blue-White Rx ____-T White-Brown Rx ____-R Brown-White Tx ____-T White-Green Tx ____-R Green-White Rx ____-T Red-Blue Rx ____-R Blue-Red Tx ____-T White-Gray Tx ____-R Gray-White Rx ____-T Red-Green Rx ____-R Green-Red Tx ____-T Red-Orange Tx ____-R Orange-Red .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Specify assignments for T1/E1 lines .................................................................................................................................................................................................................................... SEC-B T1/E1 Line # Function Tx/Rx RJ-45 Pinout # Wire Color Rx ____-T White-Orange Rx ____-R Orange-White Tx ____-T White-Blue Tx ____-R Blue-White Rx ____-T White-Brown Rx ____-R Brown-White Tx ____-T White-Green Tx ____-R Green-White Rx ____-T Red-Blue Rx ____-R Blue-Red Tx ____-T White-Gray Tx ____-R Gray-White Rx ____-T Red-Green Rx ____-R Green-Red Tx ____-T Red-Orange Tx ____-R Orange-Red Rx ____-T White-Orange Rx ____-R Orange-White Tx ____-T White-Blue Tx ____-R Blue-White Rx ____-T White-Brown Rx ____-R Brown-White Tx ____-T White-Green Tx ____-R Green-White Rx ____-T Red-Blue Rx ____-R Blue-Red Tx ____-T White-Gray Tx ____-R Gray-White Rx ____-T Red-Green Rx ____-R Green-Red Tx ____-T Red-Orange Tx ____-R Orange-Red 10 11 12 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Specify assignments for T1/E1 lines .................................................................................................................................................................................................................................... SEC-B T1/E1 Line # Function Tx/Rx RJ-45 Pinout # Wire Color 13 Rx ____-T White-Orange Rx ____-R Orange-White Tx ____-T White-Blue Tx ____-R Blue-White Rx ____-T White-Brown Rx ____-R Brown-White Tx ____-T White-Green Tx ____-R Green-White Rx ____-T Red-Blue Rx ____-R Blue-Red Tx ____-T White-Gray Tx ____-R Gray-White Rx ____-T Red-Green Rx ____-R Green-Red Tx ____-T Red-Orange Tx ____-R Orange-Red 14 15 16 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for User Alarm cables .................................................................................................................................................................................................................................... Site preparation for User Alarm cables User Alarm requirements Each generated User Alarm is generated by a set of isolated dry relay contacts. An “alarm state” may be indicated by a “closed circuit” or an “open circuit.” • • If an alarm condition is indicated by a “closed circuit,” the alarm contacts must present a contact closure when the alarm circuit fails or loses power. If an alarm condition is indicated by an “open circuit,” the alarm contacts must present an “open circuit” when the alarm circuit fails or loses power. The resistance of a “closed circuit” is less than 100 ohms. The resistance of an “open circuit” is greater than 1 megohm. The User Alarm switches (if desired) must be installed as part of site preparation. The 9927 Distributed Base Station Outdoor Cabinet cabinet is equipped with primary surge protection. User Alarm cable connections The table below provides the pin numbers, wire colors, and functions for the User Alarm cables in the 9927 Distributed BTS outdoor cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for User Alarm cables .................................................................................................................................................................................................................................... Facilities cable User Alarm cable 37 pin D-Sub Wire Color Cable 1 function Cable 2 function White-Blue USERALM0 (+) USERALM16 (+) 20 Blue-White USERALM0 (-) USERALM16 (-) White-Orange USERALM1 (+) USERALM17 (+) 21 Orange-White USERALM1 (-) USERALM17 (-) White-Green USERALM2 (+) USERALM18 (+) 22 Green-White USERALM2 (-) USERALM18 (-) White-Brown USERALM3 (+) USERALM19 (+) 23 Brown-White USERALM3 (-) USERALM19 (-) White-Gray USERALM4 (+) USERALM20 (+) 24 Gray-White USERALM4 (-) USERALM20 (-) Red-Blue USERALM5 (+) USERALM21 (+) 25 Blue-Red USERALM5 (-) USERALM21 (-) Red-Orange USERALM6 (+) USERALM22 (+) 26 Orange-Red USERALM6 (-) USERALM22 (-) Red-Green USERALM7 (+) USERALM23 (+) 27 Green-Red USERALM7 (-) USERALM23 (-) Red-Brown USERALM8 (+) USERALM24 (+) 28 Brown-Red USERALM8 (-) USERALM24 (-) 10 Red-Gray USERALM9 (+) USERALM25 (+) 29 Gray-Red USERALM9 (-) USERALM25 (-) 11 Black-Blue USERALM10 (+) USERALM26 (+) 30 Blue-Black USERALM10 (-) USERALM26 (-) 12 Black-Orange USERALM11 (+) USERALM27 (+) 31 Orange-Black USERALM11 (-) USERALM27 (-) 13 Black-Green USERALM12 (+) USERALM28 (+) 32 Green-Black USERALM12 (-) USERALM28 (-) 14 Black-Brown USERALM13 (+) USERALM29 (+) 33 Brown-Black USERALM13 (-) USERALM29 (-) 15 Black-Gray USERALM14 (+) USERALM30 (+) 34 Gray-Black USERALM14 (-) USERALM30 (-) 16 Yellow-Blue USERALM15 (+) USERALM31 (+) .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for User Alarm cables .................................................................................................................................................................................................................................... Facilities cable 35 37 pin D-Sub BlueYellow Wire Color USERALM15 (-) Cable 1 function Cable 2 function USERALM31 (-) .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 14-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation -- T1/E1 and User Alarm facilities for 9927 Distributed Base Station Outdoor Cabinet Site preparation for User Alarm cables .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 14-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 15 15 Hybriflex cable specifications Overview Purpose This chapter discusses the fiber optic cable requirements for the RRHs. The fiber optic cables are contained within the Hybriflex cable. Contents General facilities requirements 15-2 Facilities requirements 15-3 Requirements for Hybriflex cable 15-4 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 15-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Hybriflex cable specifications General facilities requirements .................................................................................................................................................................................................................................... General facilities requirements General requirements One fiber optic cable (from Hybriflex cable) is connected to each RRH. The fiber optic cables that exit the Hybriflex cable are terminated with LC connectors. All facilities must be available before the RRHs can be installed. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 15-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Hybriflex cable specifications Facilities requirements .................................................................................................................................................................................................................................... Facilities requirements Hybriflex connection at DC Distribution/Fiber Management Box The Hybriflex cable enters the DC Distribution/Fiber Management Box via a 1–1/2 inch knockout.at the bottom panel of the DC Distribution/Fiber Management Box. Connectors on bottom of RRHs The figure below shows the cable entry points on the bottom of the 800 MHz RRH. AUX RX2 AUX Rx1 CPRI PRI CPRI PRI STATUS Tx1 MON Tx2 MON ALM -48 V IN ALD .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 15-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Hybriflex cable specifications Requirements for Hybriflex cable .................................................................................................................................................................................................................................... Requirements for Hybriflex cable Overview This section specifies the requirements for the Hybriflex cable, which connects the DC Distribution/Fiber Management Box to the RRH. The Hybriflex cable contains fiber optic and DC power cables. Hybriflex cable between DC Distribution/Fiber Management Box and RRHs The fiber optic and DC power cables branch out at the pole end from the Hybriflex cable. The individual cables are 4.6 m (15 feet) long. The Hybriflex cable provided by Alcatel-Lucent meets the following requirements: • • • • • Outdoor rated Temperature rating: operation -40 to +85 °C (-40 to 185 °F), storage -55 to +85 °C (-67 to 185 °F) Bend radius: 15 x outside diameter (15 x ___ mm = _____ mm) Fiber count: 5 DC power wire count: 4 pairs • • • • Fiber type: multi-mode Attenuation: 0.5 dB/km Rugged cable Connectors: LC duplex connectors are provided at both ends of fiber cables. • • • • Maximum tensile load; 800 newtons for installation Maximum tensile load; 500 newtons for operation UL 1666, flame retardent UL listed type OFNR An excess cable length must be coiled at one or both ends and properly protected. Note: To avoid damage to the fiber optic cable, extra care must be exercised by using fiber management paper and loosely fastening the fiber optic cable to the cable rack. The fiber optic cable bend radius must be as gradual as possible [15 x diameter of cable (15 x 7 mm = 105 mm)]. Description of Hybriflex cable (supplied by Alcatel-Lucent) The Hybriflex cable is routed from the DC Distribution/Fiber Management Box to the RRHs. It provides -48 VDC power and fiber optic links to each RRH. The Hybriflex cable consists of a plastic coated, flexible metallic jacket that is weather and sunlight resistant. It contains six multi-mode fiber optic cables and four 8 AWG, stranded copper conductor pairs. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 15-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Hybriflex cable specifications Requirements for Hybriflex cable .................................................................................................................................................................................................................................... The fiber optic cables and DC cable pairs exit from each end of the Hybriflex cable. At the RRH end, the fiber optic cables and DC cable pairs are about 15 feet long. At the DC Distribution/Fiber Management Box end, they are about ___ feet long. Each fiber optic cable is terminated at each end with an LC connector. All cables are weather and sunlight resistant. Shown in the figure below is the RRH end (or top end) of the Hybriflex cable. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 15-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Hybriflex cable specifications Requirements for Hybriflex cable .................................................................................................................................................................................................................................... Shown in the figure below is the DC Distribution/Fiber Management Box end (or bottom end) of the Hybriflex cable. DC Distribution/Fiber Management Box The DC Distribution/Fiber Management Box goes between the baseband cabinet and the RRHs. The DC Distribution/Fiber Management Box contains: • DC surge protectors • • • DC circuit breakers DC terminal blocks Fiber optic cable interface connectors .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 15-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Hybriflex cable specifications Requirements for Hybriflex cable .................................................................................................................................................................................................................................... The fiber optic cable interface connectors couple the fiber optic cables from the 9927 Distributed BTS outdoor cabinet with the fiber optic cables in the Hybriflex cable The DC Distribution/Fiber Management Box must be located at the bottom of the tower, within 20 feet of the 9927 Distributed BTS outdoor cabinet. The requirements for the DC Distribution/Fiber Management Box are as follows: • • Outdoor rated UL listed • Contains six round holes for Hybriflex and 1-1/2 inch liquid-tight flexible metallic conduit from the 9228 Distributed BTS outdoor cabinet. • • Contains 48 fiber optic (LC connector) interface connectors (connect fiber optic cable from Hybriflex cable to fiber optic cable from 9927 Distributed BTS) Two DC surge protectors with the option to go up to four. • • • Contains 12 25 Amp, DC circuit breakers (can go up to 24) DC terminal block Must be Installed within 6.1 m (20 feet) of the 9927 Distributed BTS outdoor cabinet. The block diagram below shows two 1–1/2 liquid-tight flexible metallic conduits and one Hybriflex cable entering the DC Distribution/Fiber Management Box. BY OTHERS ALCATEL-LUCENT 1-1/2 INCH LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT WITH FIBER OPTIC AND -48 VDC POWER CABLES 9927 DISTRIBUTED BASE STATION OUTDOOR CABINET HYBRIFLEX CABLE DC DISTRIBUTION/ FIBER MANAGEMENT BOX FOR FIBER OPTIC CABLE AND -48 VDC Optical links between 9927 Distributed BTS cabinet and RRHs The optical links between the baseband cabinet and DC Distribution/Fiber Management Box and DC Distribution/Fiber Management Box and RRHs are via multi-mode duplex fibers: two fibers -- one for Transmit (Tx) and one for Receive (Rx). When connecting the .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary 15-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Hybriflex cable specifications Requirements for Hybriflex cable .................................................................................................................................................................................................................................... 9927 Distributed BTS cabinet to the RRHs, make certain fiber cable connector “B” is connected to Tx on the 9927 Distributed BTS cabinet and fiber cable connector “A” is connected to Rx on the RRH. Important! “A” and “B” designations are typically imprinted on the LC connector clip. The following figure shows a typical fiber cable with LC duplex connectors at the baseband cabinet and RRH end. Base station cabinet end RRH end .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor 15-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix A: 9927 Distributed Base Station Outdoor Cabinet site preparation checklists Overview Purpose This section is for use by authorized personnel to verify completion of cell site preparation activities prior to installation of base station equipment. Contents SP-GEN Cell site general information form A-2 SP-1 Site preparation general checklist A-3 SP-2 Site preparation power source checklist A-5 SP-3 Site preparation grounding checklist A-6 SP-5 Site preparation GPS antenna checklist A-9 SP-6 Site preparation punchlist sheet A-11 SP-6A Site preparation punchlist sheet A-12 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-GEN Cell site general information form .................................................................................................................................................................................................................................... SP-GEN Cell site general information form Purpose The following form must be completed prior to the installation of the cell site equipment. Form Complete the following information about the cell site. • • Cell Site Name: ________________________________ Cell Site Address: ________________________________ • • • Cell Site Access Contact Name: ________________________________ MTA Name: ________________________________ Cell Site # : ________________________________ • Contact Phone # : ________________________________ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-1 Site preparation general checklist .................................................................................................................................................................................................................................... SP-1 Site preparation general checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding item descriptions. Checklist Item # Description Yes (Y) No (N) N/A 1. Is the work site free of environmental, health and safety (EH&S) hazards? N/A 2. Are cell site environmental conditions within equipment specified operating range? N/A 3. Has the optional ice bridge been installed? N/A 4. Has the required space been provided around equipment (that is, maintenance access, cabinets, heat dissipation, safety) ? N/A 5. Is support structure properly secured and anchored per earthquake zoning requirements? N/A 6. Will structure support cabinets/equipment (including batteries, etc.) ? N/A 7. Are all site permits completed? N/A 8. Has a Method of Procedure (MOP) been developed with the installation supervisor? N/A 9. Is cell translations information available? N/A 10. Has installer cell site equipment parameter sheet been completed and reviewed with the installation supervisor? N/A 11. Are the ECP/Switch and cell software generics compatible? N/A 12. Are T1/E1 and User Alarm facilities available and active? N/A 13. If T1/E1 facility is 75 ohms coaxial, has the protection/conversion of coaxial cable to twisted-pair cable been provided? N/A Comments .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-1 Site preparation general checklist .................................................................................................................................................................................................................................... Item # Description Yes (Y) No (N) N/A 14. Is adequate primary surge protection provided for the T1/E1 service entrance? N/A 15. Are the T1/E1 long enough to reach from the T1/E1 service entrance to the punchdown block or conversion block? N/A 16. Is the conduit for routing T1/E1 and User Alarm cables to the basestand frame in place? N/A 17. Is the twisted-pair cable installed and protected for T1/E1? N/A 18. Is the twisted-pair cable installed and protected for User Alarm? N/A 19. Has all equipment been ordered and has delivery to site been scheduled? N/A 20. Have all necessary arrangements been made for access to the site? N/A 21. Have all necessary arrangements been made to get equipment onto the site (crane, etc.) ? N/A Comments Completed by: _______________________________________________________ Date: _______________________________________________________ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-2 Site preparation power source checklist .................................................................................................................................................................................................................................... SP-2 Site preparation power source checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding item descriptions. Checklist Item # Description Yes (Y) No (N) N/A 1. Is AC service available? N/A 2. Have AC service and conduits been approved by local code? N/A 3. Is AC service equipped with surge protection at service entry point? N/A 4. Is AC power source appropriate for equipment being installed? N/A 5. Does AC service have proper circuit breaker rating(s) and labeling? N/A 6. Is AC circuit breaker(s) available and labeled for power system? N/A 7. Is AC circuit breaker(s) available and labeled for listed ancillary equipment? N/A A. N/A B. N/A C. N/A 8. Do tower lighting, intrusion lighting, etc. feeds have proper lightning protection? N/A 9. If not supplied with the cabinets, have at least two AC duplex convenience outlets been provided within 1.5 meters (5 feet) of basestand frame(s)? N/A N/A Comments NOTE: A Ground Fault Circuit Interrupt (GFCI) type is recommended, and must be used when required by code. 10. Is each outlet protected by a UL/CSA listed, or approved 15 A circuit breaker? .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-3 Site preparation grounding checklist .................................................................................................................................................................................................................................... SP-3 Site preparation grounding checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding description items. Checklist Item # Description Yes (Y) No (N) N/A 1. Is soil resistivity and site resistance test on file? N/A 2. Has connection been provided to grounding electrode system? N/A Comments If yes, circle all that apply: 1. Via a buried ring ground and driven rod(s) 2. Via a buried metallic and electrically continuous water pipe 3. Via driven ground rod(s) and/or plate(s) 4. Via electrolytic ground rod(s) 5. Via grounded building steel 6. Via grounded grid or radial 3. Is lighting mast(s) or air terminal(s) provided and bonded? N/A 4. Is antenna support structure(s) grounded? N/A 5. Is antenna tower bonded to grounding electrode system? N/A 6. Are guy wires bonded to grounding electrode system? N/A 7. Are antenna cable shields grounded at both ends? N/A 8. If tower is greater than 60 meters (200 feet) high, are antenna cable shields grounded at midpoint and both ends? N/A 9. Is ice bridge bonded at both ends and 7.62-meter (25-foot) intervals? .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-3 Site preparation grounding checklist .................................................................................................................................................................................................................................... Item # Description Yes (Y) No (N) N/A 10. Are all ground connections in compliance with Alcatel-Lucent requirements (exothermic weld, compression type with 2-hole lugs; properly secured; antioxidant used on contact surface area) ? N/A 11. Are all grounding conductors routed as straight as possible with no loops or sharp bends? N/A 12. Is cabinet support structure grounded? N/A 13. Are metallic conduits bonded at both ends and 7.62 meter (25 foot) intervals? N/A 14. Are all fence corner posts and gate posts properly grounded (including fence fabric and barbed wire, as applicable) ? N/A 15. Are all metallic objects in the vicinity bonded to the grounding system? N/A 16. Is AC power supply equipped with a surge protection device and is the device properly connected to the ground system? N/A 17. Is T1/E1 line equipped with a surge protection device and is the device properly connected to the ground system? N/A 18. Is tower light system (if installed) equipped with a surge protection device and is the device properly connected to the ground system? N/A 19. Are the GPS antenna cable shields properly grounded? Is surge protection in place and properly grounded GPS antenna? N/A 21. Is supplementary conductor connected to grounding electrode system? (Exposed end, if any, must be taped.) N/A Comments .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-3 Site preparation grounding checklist .................................................................................................................................................................................................................................... Item # 22. Description Are down conductors in compliance with Alcatel-Lucent specifications? Yes (Y) No (N) N/A N/A N/A Comments (If building is less than 23 meters (75 ft.) high, use two 33.6 mm2 (2 AWG) copper conductors. If higher than 23 meters (75 feet), use two 2/0 copper conductors). 23. Is steel column used as one down conductor? Concrete Pad Cell Site Installation Only 24. Is supplementary conductor connected to grounding electrode system at both ends (if applicable) ? N/A 25. Were buried ring ground and its connections inspected before the trench was backfilled? N/A 26. Was a photo taken of the buried ring ground and its connections prior to backfilling for reference file? N/A Completed by: _______________________________________________________ Date: _______________________________________________________ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-5 Site preparation GPS antenna checklist .................................................................................................................................................................................................................................... SP-5 Site preparation GPS antenna checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding item descriptions. Checklist Item # Description Yes (Y) No (N) N/A 1. Is antenna installed with base level within two degrees? N/A 2. Is antenna installed with less than 25% of the sky masked by obstruction? N/A 3. Is GPS antenna located at least 3.05 m (10 feet) vertically and horizontally from any active transmit antenna? N/A 4. Are aggregate cable loss, cable Voltage Standing Wave Ratio (VSWR), total cable length, cable type, GPS antenna gain, KS list and serial numbers recorded in the site installation records? N/A 5. Is proper gain antenna installed for the total aggregate cable loss and length? N/A 6. Is measured cable VSWR within its specified value? N/A 7. Is GPS antenna cable properly grounded, and equipped with proper surge protection device? N/A 8. Are proper service loops provided near antenna? N/A 9. Is proper drip loop provided at the 9927 Distributed Base Station Outdoor Cabinet antenna cable cover? N/A 10. Are cable connections torqued to the appropriate value? N/A 12. Are all external cables UV rated? N/A 13. Are antenna bracket, pipes, and antenna properly secured? N/A Comments .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-5 Site preparation GPS antenna checklist .................................................................................................................................................................................................................................... Item # Description Yes (Y) No (N) N/A 14. Was GPS antenna location verified for line of sight using a Garmin 45XL test unit or equivalent? N/A 15. Is GPS antenna location free of external interference (i.e., radio stations, collocated equipment, etc.) ? N/A Comments Completed by: _______________________________________________________ Date: _______________________________________________________ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-6 Site preparation punchlist sheet .................................................................................................................................................................................................................................... SP-6 Site preparation punchlist sheet Purpose The following punchlist is used to track any outstanding site preparation items. Punchlist Item # Comment/Description Severity (1/2/3) Corrective Action Required (Y/N) Completed Date Severity Column Definitions: 1. Equipment installation cannot occur until outage is rectified and will void warranty or potentially cause personal injury. 2. Equipment installation can occur but issue must be rectified prior to hand-off to customer or service turn-up so that the warranty is not voided. 3. Equipment installation, hand-off to customer, or service turn-up can occur but not per Alcatel-Lucent recommendations. Inspection Checklist Completion Sign-Off Was the punchlist continuation sheet on the next page used? □ Yes □ No Inspector's Name: _________________________________________________ Inspector's Signature: _________________________________________________ Date: _________________________________________________ .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary A-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet site preparation checklists SP-6A Site preparation punchlist sheet .................................................................................................................................................................................................................................... SP-6A Site preparation punchlist sheet Purpose The following punchlist is used to track any outstanding site preparation items. Punchlist Item Comment/Description Severity (1/2/3) Corrective Action Required (Y/N) Completed Date .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor A-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix B: Site preparation checklists for RRHs Overview Purpose This section is for use by authorized personnel to verify completion of cell site preparation activities prior to installation of base station equipment. Contents SP-GEN cell site general information B-2 SP-1 Site preparation general checklist B-3 SP-2 Site preparation power source checklist B-6 SP-3 Site preparation grounding checklist B-7 SP-4 Site preparation RF antenna checklist B-9 SP-5 Site preparation punchlist sheet B-11 SP-5A Site preparation punchlist sheet B-12 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-GEN cell site general information .................................................................................................................................................................................................................................... SP-GEN cell site general information Complete the following information about the cell site: • • Cell Site Name: ______________________ Cell Site Address: ______________________ • • • • Cell Site Access Contact Name: ______________________ MTA Name: ______________________ Cell Site #: ______________________ Contact Phone #: ______________________. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation checklists for RRHs SP-1 Site preparation general checklist .................................................................................................................................................................................................................................... SP-1 Site preparation general checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding item descriptions. Item # Description Yes (Y) No (N) N/A 1. Are cell site environmental conditions within equipment specified operating range? N/A 2. Has the required space been provided around equipment [i.e., maintenance access, cabinet(s), heat dissipation, safety]? N/A 3. Has a Method of Procedure (MOP) been developed with the installation supervisor? N/A 4. Is cell translations information available? N/A 5. Has installer cell site equipment parameter sheet been completed and reviewed with the installation supervisor? N/A Are the ECP/Switch and cell software generics compatible? N/A 7. Are user alarm facilities available and active? N/A 8. Is adequate primary surge protection provided for the user alarms? N/A 9. Have the user alarm cables been installed and terminated in the alarm interface and alarm block (or equivalent)? N/A 10. Are fiber optic facilities (splicing/DC Distribution/Fiber Management Box) available and active? N/A Comments .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-1 Site preparation general checklist .................................................................................................................................................................................................................................... Item # Description Yes (Y) No (N) N/A 11. Have the fiber optic cables been installed for termination at the ALU equipment or at the demarcation point (slicing/DC Distribution/Fiber Management Box)? N/A 12. Is the RRH and distributed base station (9234 d2U or 9222 or 9228) going to be co-located or within 328 ft.? N/A 13. Is the Standard Fiber Cable assembly (15 ft., 50 ft., 100 ft., etc.) installed and available at the site? N/A 14. Is the RRH and distributed base station (9234 d2U or 9222 or 9228) installed as non-co-located separated more than 328 ft.? N/A 15. Has the customer supplied and installled Splicing/Junction Boxes at both RRH and distributed base station (9234 d2U or 9222 or 9228) sides? N/A 16. Has the customer supplied and installled proper fiber between the Splicing/Junction Boxes ? N/A 17. Is there a standard 50 ft. fiber cable assembly installed and available from Splicing/DC Distribution/Fiber Management Box to near the distributed base station (9234 d2U or 9222 or 9228) and RRH frames? N/A 18, Is the fiber cable properly protected and extra length (if any) coiled up and stored properly? 19. Has all equipment been ordered and has delivery to site been scheduled? N/A 20. Have all necessary arrangements been made for access to the site? N/A 21. Have all necessary arrangements been made to get equipment onto the site (crane, etc.)? N/A Comments .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation checklists for RRHs SP-1 Site preparation general checklist .................................................................................................................................................................................................................................... Notes: 1. Completed by: ______________________ 2. Date: _______ .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-2 Site preparation power source checklist .................................................................................................................................................................................................................................... SP-2 Site preparation power source checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding item descriptions. Item Description Yes (Y) No (N) N/A 1. Is AC / DC service available? N/A 2. Have AC / DC service and conduits been approved by local code? N/A 3. Is AC / DC service equipped with surge protection at service entry point? N/A 4. Is AC / DC power source appropriate for equipment being installed? N/A 5. Does AC / DC service have proper circuit breaker rating(s) and labeling? N/A 6. Is AC / DC circuit breaker(s) available and labeled for power system? N/A 7. Is AC / DC circuit breaker(s) available and labeled for listed ancillary equipment? N/A A. N/A B. N/A C. N/A 8. Do tower lighting, intrusion lighting, etc. feeds have proper lightning protection? N/A 9. If not supplied with the cabinets, have at least two AC duplex convenience outlets been provided within 1.5 meters (5 feet) of radio cabinet(s)? N/A N/A Comments NOTE: A Ground Fault Circuit Interrupt (GFCI) type is recommended, and must be used when required by code. 10. Is each outlet protected by a UL/CSA listed, or approved 15 A circuit breaker? .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation checklists for RRHs SP-3 Site preparation grounding checklist .................................................................................................................................................................................................................................... SP-3 Site preparation grounding checklist Purpose The following items must be completed prior to the installation of the cell site equipment. Circle the correct letter for the corresponding description items. Item Description Yes (Y) No (N) N/A 1. Is soil resistivity and site resistance test on file? N/A 2. Has connection been provided to grounding electrode system? N/A Comments If yes, circle all that apply: A. Via a buried ring ground anddriven rod(s) B. Via a buried metallic and electrically continuous water pipe C. Via driven ground rod(s) and/or plate(s) D. Via electrolytic ground rod(s) E. Via grounded building steel F. Via grounded grid or radial 3. Is lighting mast(s) or air terminal(s) provided and bonded? N/A 4. Is antenna support structure(s) grounded? N/A 5. Is antenna tower bonded to grounding electrode system? N/A 6. Are guy wires bonded to grounding electrode system? N/A 7. Are antenna cable shields grounded at both ends? N/A 8. If tower is greater than 60 meters (200 ft.) high, are antenna cable shields grounded at mid-point and both ends? N/A 9. Is ice bridge bonded at both ends and 7.62-meter (25-foot) intervals? N/A .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-3 Site preparation grounding checklist .................................................................................................................................................................................................................................... Item Description Yes (Y) No (N) N/A 10. Are all ground connections in compliance with Alcatel-Lucent requirements (exothermic weld, compression type with 2-hole lugs; properly secured; anti-oxidant used on contact surface area)? N/A 11. Are all grounding conductors routed as straight as possible with no loops or sharp bends? N/A 12. Is cabinet support structure grounded? N/A 13. Are metallic conduits bonded at both ends and 7.62 meter (25 foot) intervals? N/A 14. Are all fence corner posts and gate posts properly grounded (including fence fabric and barbed wire, as applicable)? N/A 15. Are all metallic objects within 1.8 meters (6 feet) bonded to the grounding system? N/A 16. Is AC / DC power supply equipped with a surge protection device and is the device properly connected to the ground system? N/A 17. Is tower light system (if installed) equipped with a surge protection device and is the device properly connected to the ground system? N/A 18. Are the RF surge protection devices properly connected to the ground system? N/A Comments Notes: 1. Completed by: ______________________ 2. Date: _______ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation checklists for RRHs SP-4 Site preparation RF antenna checklist .................................................................................................................................................................................................................................... SP-4 Site preparation RF antenna checklist Purpose The following items must be completed prior to the installation of the RF cell site equipment. Circle the correct letter for the corresponding item descriptions. Item Description Yes (Y) No (N) N/A 1. Is tower properly installed and secured? N/A 2. Are all antenna cable runs installed? N/A 3. Are all antenna cable runs properly terminated with 7/16 DIN female connectors on the equipment side? N/A 4. Are all cable connections torqued to the appropriate value? N/A 5. Are the RF antenna cables equipped with surge protection devices? 6. Are all external cables UV rated? N/A 7. Are antenna cable runs' demarcation points in proper location? N/A 8. Are antenna cable runs marked and in proper sequence per applicable equipment drawings? N/A 9. Are appropriate type, length and number of antenna cable jumpers available? N/A 10. Are appropriate drip loops provided for antenna cable runs at turns and demarcation point? N/A 11. Have antenna and cable sweeps been performed? N/A 12. Are antennas properly installed and secured? N/A 13. Are all antennas the proper type? N/A 14. Are all antennas at proper azimuth? (0,120 or 240 degrees) N/A 15. Are antennas at proper height? N/A 16. Are antennas at proper tilt? N/A Comments .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-4 Site preparation RF antenna checklist .................................................................................................................................................................................................................................... Item Description Yes (Y) No (N) N/A 17. Have diversity antennas been properly separated? N/A 18. Are antenna hatchplate and cable boots properly installed? N/A Comments Notes: 1. Completed by: ______________________ 2. Date: _______ .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Site preparation checklists for RRHs SP-5 Site preparation punchlist sheet .................................................................................................................................................................................................................................... SP-5 Site preparation punchlist sheet Purpose The following punchlist is used to track any outstanding site preparation items. Item # Comment/Description Severity (1/2/3) Corrective Action Required (Y/N) Completed Date Notes: 1. Equipment installation cannot occur until outage is rectified and will void warranty or potentially cause personal injury. 2. Equipment installation can occur but issue must be rectified prior to handoff to customer or service turn-up so that the warranty is not voided. 3. Equipment installation, handoff to customer, or service turn-up can occur but not per Lucent recommendations. 4. Inspection Checklist Completion Sign-Off (complete below) 5. Was the punchlist continuation sheet on the next page used? Yes or No 6. Inspector's Name: ______________________ 7. Inspector's Signature: _____________________ Date: _________ .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary B-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Site preparation checklists for RRHs SP-5A Site preparation punchlist sheet .................................................................................................................................................................................................................................... SP-5A Site preparation punchlist sheet Purpose The following punchlist is used to track any outstanding site preparation items. Item # Comment/Description Severity (1/2/3) Corrective Action Required (Y/N) Completed Date .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor B-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix C: 9927 Distributed Base Station Outdoor Cabinet cell site information Overview Purpose This section is for use by Customer Project Management to document cell site configuration information. Contents CSC-1 Cell site configuration information C-2 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary C-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet cell site information CSC-1 Cell site configuration information .................................................................................................................................................................................................................................... CSC-1 Cell site configuration information General base station information Complete the following cell site information: Cell Site information (provided by inspector) Name Address Contact name MTA name Cell Site # Contact Phone & Pager # Installation type Check all that apply: • • • □ Indoor □ Outdoor □ Controlled Environment • • • • □ Uncontrolled Environment □ Concrete Pad □ Rooftop □ Other (Specify) : ___________________________________________ Base station substructure Check all that apply: • □ Concrete • • • □ Wood floor □ Raised floor □ Non-Penetrating • • • □ I-beam □ C-beam □ Platform .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor C-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet cell site information CSC-1 Cell site configuration information .................................................................................................................................................................................................................................... Earthquake zone rating Check one: • • □ Zone 0 □ Zone 1 • • • □ Zone 2 □ Zone 3 □ Zone 4 Base station equipment Complete the information for the 9927 Distributed Base Station Outdoor Cabinet equipment: Cabinet Type Serial # # of sector Duplex/ Triplex/ Dual Duplex Primary cabinet Growth cabinets Battery cabinet Antennas Complete the following (if required) : PCS Channel # (1-1999) ___________________________________________ # of Carriers (1-9) ___________________________________________ GPS Antenna KS/Model ___________________________________________ PCS Freq. Block (A-F) ___________________________________________ GPS Cable Length (ft.) ___________________________________________ GPS Antenna Gain (dB) ___________________________________________ Microwave Antenna Type (_____) ___________________________________________ Power Total # of Battery Strings ___________________________________________ Power source, if any • □ -48 VDC .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary C-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet cell site information CSC-1 Cell site configuration information .................................................................................................................................................................................................................................... Integrated power? • • □ Yes □ No External power? • • □ Yes □ No Power collocated with base station equipment? • • □ Yes □ No Other cell site equipment Complete the following: Equipment description Yes (Y) No (N) N/A Antenna Tower? N/A FAA Lighting? N/A Tower Light Alarm? N/A Ice Bridge? N/A N/A Antenna Cable Hatch Plate? Number of Entry Holes ____ N/A Facilities Ancillary Equipment? N/A Covering: (check one) ____ Cables Only ____ Cables and Equipment Cable Tray or Ladder Racks? Type of Ladder: (check one) ____ 5' Ladders ____ 12' Ladders ____ Other: ____ Power Source: (check one) ____ AC ____ DC Voltage: (check one) ____ DC ____ rms .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor C-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet cell site information CSC-1 Cell site configuration information .................................................................................................................................................................................................................................... Equipment description Yes (Y) No (N) N/A Earthquake Bracing Required? N/A Tx/Rx Antenna? N/A AC Service: Size (amps) ____ Voltage (v) ____ Phase (1 or 3) ____ Customer-supplied Power System? NOTE: If YES, the customer is responsible for the configuration of the power system. (mounting location) ____ Tower ____ Steel Structure ____ Building ____ Antenna Support Structure Cell Site Grounding? If YES, select all that apply: ____ Buried ring ground and driven rods ____ Buried metallic and electrically continuous water pipe ____ Down conductors (Quantity: ____) ____ Electrolytic ground rod(s) (Quantity :____) ____ Driven ground rod(s) (Quantity :____) ____ Grounded building steel ____ Ground grid ____ Ground radial(s) (Quantity :____) Collocated non-PCS equipment? Existing grounding system: ____ Single Point ____ Integrated Ground Bus? If YES, quantity: ____ .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary C-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 9927 Distributed Base Station Outdoor Cabinet cell site information CSC-1 Cell site configuration information .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor C-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix D: Guidelines for lifting and moving cabinets Overview Purpose This Appendix provides guidelines for lifting and moving the 9927 Distributed Base Station Outdoor Cabinet cabinets and the 60ECv2 battery cabinet. Contents Lifting and moving cabinets D-2 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary D-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Guidelines for lifting and moving cabinets Lifting and moving cabinets .................................................................................................................................................................................................................................... Lifting and moving cabinets Purpose Cabinets are usually shipped to the customer via truck and are delivered to the installation site. During installation, it may be necessary to lift the cabinet to move it to a new location. This section describes how to safely lift the cabinets. Use this information as you perform the lifting procedures. WARNING Equipment damage A dolly with straps can damage the front air filter cover and the rear muffler cover of the 9927 cabinet if too much tension is applied to the straps. When a dolly with straps is used to move the 9927 Distributed Base Station Outdoor Cabinet, adjust the straps and the tension so that the air filter cover and the rear muffler cover are not damaged by the straps. Lifting machinery To lift the cabinet, do one of the following: • • Use a forklift with forks that are at least 4 feet long to lift a cabinet attached to a pallet from the bottom. Install lifting eyebolts on the top of the cabinet, and use a derrick and slings to lift the cabinet from its top. Safety precautions for using lifting machinery WARNING Personnel injury or equipment damage Cabinets are too heavy to move without appropriate lifting devices. Derrick equipment or a forklift must be used to lift the cabinet. Do not attempt to move the cabinet manually, or remove it from the pallet manually. Comply with the following guidelines when using lifting machinery: • • Only operators who are specifically trained and meet company requirements should be permitted to operate derrick or forklift equipment. All persons working with derricks or forklifts must wear standard safety headgear, footwear, eye protection, and insulated gloves (if required). .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor D-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Guidelines for lifting and moving cabinets Lifting and moving cabinets .................................................................................................................................................................................................................................... • • Do not operate a derrick until both stabilizers are extended and firmly supported. Do not extend stabilizers after a load is suspended from the derrick. While raising the derrick from the stowed position, be alert for overhead obstructions, such as power lines, that may interfere. • • At all times, keep bystanders away from the work area. Operators must not suspend loads over people, nor can any person be permitted to work, stand, or pass under a suspended load. • When a cabinet is being lifted with slings, it is unsafe to lift the cabinet when lifting sling angle is less than 45 degrees to the top of the cabinet. Guidelines for using a derrick When a derrick is used to move a cabinet, lifting eyebolts and slings are used to attach the cabinet to the derrick. Lifting eyebolts DANGER Cabinet lifting hazard! When lifting cabinets, incorrect or improperly installed eyebolts will fail endangering personnel to bodily injury and destroying the equipment. Avoid using the wrong eyebolts by following these guideline: • If a ½ inch eyebolt threads easily and fully into a lifting nut on the top of the cabinet, then use the ½ inch eyebolts. • If not, check the threads for 12 mm eyebolts. The 12 mm eyebolt should thread all the way down without binding, until it bottoms out. A 12 mm eyebolt is too small for a ½ inch lifting nut, but will not hand thread all the way into the ½-inch nut unless forced. It will cross thread if forced, and may pull out when hoisting, presenting a serious danger. Do NOT force 12 mm eyebolts into ½ inch lifting nuts. Doing so will damage the threads of the lifting nuts. A ½ inch eyebolt will thread less than half a thread into a 12 mm lifting nut. Do NOT force ½ inch eyebolts into 12 mm lifting nuts. Doing so will damage the threads of the lifting nuts. • • Install lifting eyebolts on 9927 cabinets Four R-ITE-6110 M12, or Four R-ITE-6113 1/2-inch lifting eyebolts are screwed into the lifting nuts on the top of the cabinet, as shown in the following figure. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary D-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Guidelines for lifting and moving cabinets Lifting and moving cabinets .................................................................................................................................................................................................................................... Lifting nuts for Eyebolts Lifting Eyebolt Plane of Eyebolt TOP VIEW TOP VIEW Position each lifting eyebolt so that the plane of the eyebolt points at the center of the top of the cabinet, as shown in the previous figure. When this is done, and the load is applied, the plane of the eyebolt will align with the load. Eyebolts that are not aligned with the load can bend as the load pulls on them sideways. Refer to the following figure for the correct method to install the lifting eyebolts. Install lifting eyebolts on 60ECv2 cabinet Two R-ITE-6113 1/2 inch lifting eyebolts are screwed into the lifting nuts on the top of the cabinet, as shown in the following figure. Important! Do NOT use R-ITE-6110 M12 eyebolts to lift the 60ECv2 cabinet. Lifting eyebolts Sling .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor D-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Guidelines for lifting and moving cabinets Lifting and moving cabinets .................................................................................................................................................................................................................................... Secure each lifting eyebolt at the top of the cabinet, as shown in the previous figures, and ensure the shoulder of the eyebolts is properly seated. Refer to the following figure for the correct method to install the lifting eyebolts. Install lifting eyebolts Slings Attach the slings to the boom line with a B connecting link or clevis. Attach the other ends of the slings to the lifting eyebolts with a B connecting link or clevis. When a cabinet is being lifted with slings, it is unsafe to lift the cabinet when the lifting sling angle is less than 45 degrees to the top of the cabinet. At closer than 45 degrees, there is too much side stress on the lifting eyebolts. Use slings that are long enough to keep the lifting sling angle at greater than 45 degrees from the top of the cabinet. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary D-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Guidelines for lifting and moving cabinets Lifting and moving cabinets .................................................................................................................................................................................................................................... Modular Cell cabinet 60ECv2 battery cabinet Boom line Boom line B connecting link or clevis B connecting link or clevis Slings Slings Slings Lifting sling angle Lifting Eyebolt Lifting Eyebolt Unsafe if lifting sling angle is less than 45 degrees to the top of the cabinet. Lifting sling angle Unsafe if lifting sling angle is Less than 45 degrees To the top of the cabinet. Control the cabinet while it is being lifted NOTICE When Moving Cabinet When moving a cabinet, do not tilt the cabinet beyond 30 degrees from vertical. Do not stand under the cabinet. A rope tied to the pallet attached to the cabinet should be used to guide the cabinet while it is being lifted. The rope must be sufficiently long. As the cabinet is being lifted and transported, use the rope to guide the cabinet and prevent the cabinet from tilting or swinging. Always lift cabinets carefully. Also, keep the boom line tight to prevent the cabinet from tipping while the cabinet is being moved. At the end of the lift, slowly place the cabinet on the ground. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor D-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix E: GPS antenna installation Overview Purpose This appendix contains the information needed to install the GPS antenna. Contents GPS antenna installation (general) E-2 RF interference considerations E-4 Lightning interference consideration E-5 GPS antenna mount kit E-9 GPS antenna mounting instructions E-11 Active GPS antenna Standard Wave Ratio (SWR) test E-15 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation GPS antenna installation (general) .................................................................................................................................................................................................................................... GPS antenna installation (general) Site selection The GPS antenna installation site should be selected such that the maximum aggregate of all blockages above the 10 degree mask angle, such as buildings or mountains, does not exceed 25% of the surface area of a hemisphere around the GPS antenna. This blockage should not be in one contiguous quadrant of the hemisphere. Each contiguously blocked quadrant should be less than 12.5% of the sphere's surface area. The following diagram shows the mask angle definition for the GPS antenna. Important! Do not install the GPS antenna directly under structures that may accumulate or shed snow or ice. It is desirable that the antenna has the clearest view to the south, east, and west in the northern hemisphere and to the north, east, and west in the southern hemisphere. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation GPS antenna installation (general) .................................................................................................................................................................................................................................... Obstructions and interference The following types of obstructions and possible sources of interference need to be considered: • Hills, mountains, trees and surrounding plant life. • Adjacent buildings or any large sky obstructing structures such as grain elevators, airplane hangers, bridges, overhead roadways, etc. • Water towers or any close range large metal objects that could cause excessive sky obstruction. Any locations where birds or animals may easily nest or build on or around the antenna. Any collocated RF transmission antennas, TV stations, cable television cables, or arc-welding equipment. High-voltage lines will not cause interference with GPS signal reception. Self-supporting or guyed towers will generally not block the GPS signal. Trees do not totally block but rather degrade GPS reception, especially during periods of heavy rain or snow. Consider if increased summer plant life could also become a problem. If a GPS antenna is mounted to a monopole antenna mast, it must be mounted a minimum distance (D) from the monopole such that less than 12.5% of a contiguous surface area of a hemisphere around the antenna is blocked by the monopole. The GPS antenna must be spaced a minimum distance D = 1.61 x R (where R is the radius of the monopole at the attachment point of the GPS antenna), from the outside surface of the monopole. • • • • • • Example: Monopole radius (inches) R = 12 D = (1.61 x 12) D = 19.3" minimum This example assumes, of course, that the monopole is the only obstruction to be considered, and constitutes a contiguous 12.5% blockage of the sky. This condition would constitute a contiguous blockage in one quadrant of the hemisphere. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation RF interference considerations .................................................................................................................................................................................................................................... RF interference considerations RF interference considerations The GPS antenna installation site should be chosen such that it is not in a direct radiation pattern of the cell site transmit antennas, and situated such that no other antennas, microwave transmit dishes, and other sources of RF radiation that could affect GPS reception are in close proximity. The GPS antenna should not be located within 10 feet horizontally and 10 feet vertically from any actively transmitting antenna. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation Lightning interference consideration .................................................................................................................................................................................................................................... Lightning interference consideration Lightning considerations Industry standard practices for lightning protection should be followed for GPS antenna installations. Several sources for such information are: • • • Grounding and Lightning Protection Guidelines for Alcatel-Lucent Network Wireless System Cell Sites, 401-200-115 National Fire Protection Association (NFPA), NFPA 780, Standard for Installation of Lightning Protection Systems Poly Phaser Corporation “The Grounds” for lightning protection and grounding solutions for communication sites. The GPS antenna should be installed such that it is not the highest point in an installation (The GPS antenna must not be a lightning rod). The GPS antenna must be within the “protective cone” (see Figure on the following page) of any grounded structure such as an antenna tower or ancillary lightning rod. The “protective cone” is the area between the circumference of a circle with a 150 foot radius that tangentially touches the ground and the side or top of a grounded structure and the ground or structure. Protective cone installation The following diagram shows the GPS antenna installed within the protective cone. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation Lightning interference consideration .................................................................................................................................................................................................................................... Important! The percentage of protection for the shaded zone is 96%. Lightning rod installation If the GPS antenna is mounted to the side of an antenna tower above the 150 foot point, then horizontal lightning rods must be employed such that the antenna is within the area of a 150 foot sphere that touches both lightning rods, as shown in the following diagram. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation Lightning interference consideration .................................................................................................................................................................................................................................... In addition, the GPS antenna coaxial cable shield shall be bonded at one point minimum near the equipment and/or hatch plate, provided the GPS antenna is installed in the cone of protection using short (less than 60 feet) coaxial cable. Important! If the coaxial cable run along the tower is more than 60 feet, then the coaxial cable shield shall be grounded at multiple points near the antenna and equipment, at 100 foot intervals. Preventing Arc-over between structures and antenna If the GPS antenna is mounted on a separate pole or structure of height (H) near an antenna tower or other grounded structure, and the distance (D) from the pole or structure to the tower or other grounded structure is less than the height of the pole divided by six (H/6), then the pole or structure and the antenna tower must be bonded together eliminate possible arc over during a lightning strike. Example: If the pole is 50 feet tall, then D=8.3 feet. (50/6 = 8.3). Refer to the following diagram for more detail. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation Lightning interference consideration .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation GPS antenna mount kit .................................................................................................................................................................................................................................... GPS antenna mount kit General GPS antenna mount kit are available from Andrews in several forms. The standard mount kit (denoted by the letters MS at the end of the part number) contains two separate kits that can be used together or separately in the installation of the mount. These separate kits are the Collar Bracket Mount Kit (part number 602214) and the L-Bracket Mount Kit (part number 602215). Alternatively, any one of these kits may be installed if the user requires. Remaining mount kit material may be retained for later use. GPS-QBW-26NMS The GPS-QBW-26NMS is a self contained GPS antenna and mount kit. The kit includes a right hand circularly polarized antenna that incorporates a 26 dB high performance low noise amplifier as well as mounting hardware to attach the antenna to vertical pipe within a range of diameter. Pipe diameter The L-Bracket Mount Kit will attach the GPS antenna onto a customer-supplied vertical pipe of diameter ranging between 3/4" to 1/12". Important! Before installing any components ensure that the mounting pipe is the correct diameter and free of any components from previous installations. This kit contains two mounting bracket types. The two brackets can be used together, as the standard mount kit, or separately as the L-Bracket Mount or the Collar Bracket Mount. The three mounting arrangements are covered in the following section. NOTICE Equipment Damage Twisting a cable can damage the cable. DO NOT TWIST ANTENNA TO ATTACH OR REMOVE CABLE. Bracket mount kits parts lists The following table provides description of the mounting kit parts. Collar Bracket Mount Kit (Part #602214) Item # Part # Quantity Description 1a 602186 Collar .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation GPS antenna mount kit .................................................................................................................................................................................................................................... Collar Bracket Mount Kit (Part #602214) Item # Part # Quantity Description 602190 Gasket 3a 602189 #10-32 UNF x 0.5" Captive Screw 4a 9978-78 0.25" - 20 UNC-3A x 1.0" Set Screw 5a 9903-7 Allen Wrench L- Bracket Mount Kit (Part #602215) Item # Part # Quantity Description 1b 602187-2 L - Bracket 602190 Gasket 3b 9845-2 #10-32 UNF x 0.312" Screw 4b 726042 Cleat 5b 9963-131 0.25" - 20 UNCx2.5" Hex Head Cap Screw 6b 9963-256 0.25" - 20 UNCx3.25" Hex Head Cap Screw 7b 9974-15 0.25" Lockwasher 8b 9999-57 0.25" - 20 Hex Nut .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation GPS antenna mounting instructions .................................................................................................................................................................................................................................... GPS antenna mounting instructions Standard mount kit Perform the following steps and refer to the following diagram to mount the GPS antenna. (See “Bracket mount kits parts lists” (p. E-9) on the previous page for part's description). ................................................................................................................................................................................................... Attach L-Bracket, Item 1b, to customer-supplied vertical pipe using bolts (Items 5b or 6b to suit) and Items 4b, 7b and 8b. Locate in desired position. ................................................................................................................................................................................................... Tighten 0.25 inch hardware. ................................................................................................................................................................................................... Insert the cable assembly, fitted with N male connector, through the Collar, Item 1a, and Gasket, Item 2. Install Captive Screws, Item 3a. Do not install set screws, Items 4a, for this configuration. ................................................................................................................................................................................................... With Gasket, Item 2, on top of the L- Bracket, insert cable assembly through L-Bracket and Gasket. Attach the cable assembly to the GPS antenna and tighten the connector as required. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation GPS antenna mounting instructions .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... Slide the Collar and Gasket up to the antenna and attach to the antenna by pushing through the four Captive screws through the Gaskets and tighten them into the antenna base. ................................................................................................................................................................................................... Install weatherproofing that extends from directly underneath the flange on the collar bracket to at least 3 inches below the bottom of the collar measured on the cable assembly. The unused set screw holes will be covered. Important! Weatherproofing is not provided with this kit. E................................................................................................................................................................................................... N D O F S T E P S L-bracket mount kit Perform the following steps and refer to the following diagram to mount the GPS antenna. ................................................................................................................................................................................................... Attach L-Bracket, Item 1b, to customer-supplied vertical pipe using bolts (Items 5b or v 6b to suit) and Items 4b, 7b and 8b. Locate in desired position. GPS ANTENNA 7b 8b 1b “L” TYPE BRACKET 4b 3b SHORT SCREWS 5b or 6b “L” - BRACKET MOUNT ................................................................................................................................................................................................... Tighten 0.25 inch hardware. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation GPS antenna mounting instructions .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... With a Gasket, Item 2, on top of the L-Bracket, insert cable assembly through L-Bracket and Gasket. Attach the cable assembly to the GPS antenna and tighten the connector as required. ................................................................................................................................................................................................... Insert the four short, Item 3b, screws through the L-Bracket and Gasket and attach antenna and tighten screws. Do not use the Captive Screws for this configuration. ................................................................................................................................................................................................... Install weatherproofing that extends at least 2 inch below the bottom of the connector on the cable assembly to directly underneath the base plate of the antenna. Important! Weatherproofing is not provided with this kit. E................................................................................................................................................................................................... N D O F S T E P S Collar mount kit Perform the following steps and refer to the following diagram to mount the GPS antenna. ................................................................................................................................................................................................... Install Captive Screws, Item 3a, and Set Screws, Item 4a, in Collar, Item 1a, then push GPS ANTENNA 3a 1a COLLAR TYPE MOUNTING BRACKET 4a COLLAR MOUNT BRACKET Captive Screws, Item 3a, through Gasket, Item 2, holes in order to retain Gasket. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation GPS antenna mounting instructions .................................................................................................................................................................................................................................... ................................................................................................................................................................................................... Insert the cable assembly fitted with N male connector through the customer-supplied vertical mounting pipe, and Collar and Gasket assembly previously prepared. ................................................................................................................................................................................................... Attach cable assembly to the GPS antenna and tighten connector as required. ................................................................................................................................................................................................... Attach Collar and Gasket assembly to antenna and tighten Captive Screws, Item 3a, into antenna base. ................................................................................................................................................................................................... Slide assembly down so that the Collar slides over the mounting pipe. Tighten Set Screws, Item 4a. ................................................................................................................................................................................................... Install weatherproofing that extends from directly underneath the flange on the collar bracket to at least 3 inches below the bottom of the collar measured on the cable assembly. Important! Weatherproofing is not provided with this kit. E................................................................................................................................................................................................... N D O F S T E P S .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-14 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 GPS antenna installation Active GPS antenna Standard Wave Ratio (SWR) test .................................................................................................................................................................................................................................... Active GPS antenna Standard Wave Ratio (SWR) test SWR test The RF signals from the GPS satellites are extremely low-level microwave signals that must reach the RFTG with minimal distortion and loss. To verify the RF integrity of the complete antenna and cable system, a Standing Wave Ratio (SWR) or Distance-to-Fault (DTF) test should be performed. Since the GPS antenna is an active device, a standard SWR or DTF test setup cannot be used. A Bias-T must be employed to inject +5 VDC into the RF line to power the antenna's Low Noise Amplifier (see Figure below). Important! The antenna will meet it's specified SWR only when powered in this way. Calibrate the Wiltron as shown and per the manufacturer's instructions. Perform the SWR or DTF measurement as shown and per the manufacturer's instructions. Record the MAX SWR indicated and/or DTF data. If it MAX SWR is greater than 2.5, the fault must be repaired and the antenna and cable retested. GPS Antenna 5 VDC Power Supply Digi-Key T309-ND DC RF & DC Bias-T RF GPS Antenna Cable Calibrate Wilton at output of Bias-T Mini-Circuits ZFBT-4R2G-FT Wiltron Site Master F1=1570.0 MHz F2=1580.0 MHz Antenna SWR spec. MAX SWR = 2.5 (7.4 dB return loss) Digi-Key (800) 344-4539 Mini-Circuits (800) 654-7949 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary E-15 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 GPS antenna installation Active GPS antenna Standard Wave Ratio (SWR) test .................................................................................................................................................................................................................................... .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor E-16 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix F: Power and Battery Engineering Rules for 9927 Distributed Base Station Outdoor Cabinet Overview Purpose This appendix contains a copy of the document Power & Battery Engineering Rules for Alcatel-Lucent CDMA Modular Cell 4.0B, ER_0102_0004_PWR, which is the primary source for power requirements and battery backup information for the 9927 Distributed Base Station Outdoor Cabinet. Contents Engineering Rules Document F-2 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary F-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Power and Battery Engineering Rules for 9927 Distributed Base Station Outdoor Cabinet Engineering Rules Document .................................................................................................................................................................................................................................... Engineering Rules Document Description The remaining pages of this appendix are the pages of the Power & Battery Engineering Rules for Alcatel-Lucent CDMA Modular Cell 4.0B, ER_0102_0004_PWR. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor F-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Appendix G: Product conformance statements Overview Purpose This section presents the product conformance statements that apply to the 9228 Base Station cabinet. In regions such as North America and the European Union, the statements that are required are determined primarily by national or multinational regulations. However, in some regions, contract terms determine which statements are required. The presence of the statement indicates that the product does comply with that statement wherever it is required to do so. Contents Canada G-2 European Union G-5 United States G-10 ................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-1 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements Canada .................................................................................................................................................................................................................................... Canada Introduction The statements that follow are the product conformance statements that apply to the 9228 Base Station sMacro cabinet when deployed in Canada. Industry Canada ICES-003: Interference-Causing Equipment Standard Digital Apparatus This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. IC CS-03: Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing Aids Compatibility This product meets the applicable Industry Canada technical specifications. RF approval RSS-132: Cellular Telephones Employing New Technologies Operating in the Bands 824-849 MHz and 869-894 MHz The term “IC” before the certification/registration number only signifies that the Industry Canada technical specifications were met. RSS-133: PCS Radio Standards Specifications The term “IC” before the certification/registration number only signifies that the Industry Canada technical specifications were met. Product safety conformance The 9228 Base Station cabinet is Safety Certified ITE by Underwriters Laboratories (UL) and UL Canada. This Certification is marked on the equipment main nameplate label. Should the local Authority Having Jurisdiction (AHJ) require prior or additional verification of this Certification, a Product Certificate of Compliance can be obtained from the specific Certification Body by the Business/Product Unit Applicant for the product or by contacting: Technical Support Services, within Canada: +1 630 224 4672, prompt 2 Any modifications to this equipment are not permitted without review and official written authorization from the specific Certification Body. Unauthorized changes may violate the Product Safety Certification. Modifications or changes authorized by official CN/CNN are assumed to have received prior approval from this Lab. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-2 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements Canada .................................................................................................................................................................................................................................... Antenna exposure Antenna installations for the 9228 Base Station cabinet shall be performed in accordance with all applicable manufacturer's recommendations, and national laws and regulations. To ensure correct antenna installation, the antenna installer shall perform all necessary calculations and/or field measurements to evaluate compliance with applicable national laws or regulations regarding exposure to electromagnetic fields. The supplier of radio equipment, the supplier of antenna equipment and the integrator and builder of the site must provide sufficient information so that the limits of the exclusion zones can be determined. Any changes to the antenna or other equipment in the transmit path may require re-evaluation of the exposures to electromagnetic fields. Human exposure Pursuant to Health Canada Safety Code 6, Limits of Human Exposure to Radio frequency Electromagnetic Fields in the Frequency Range from 3 kHz to 300 GHz, all installations must be evaluated against the Maximum Exposure Limits as described in Chapter 2, Health Canada 99-EHD-237. Optical transmitters Alcatel-Lucent declares that 9228 Base Station cabinet complies with the International Electrotechnical Commission (IEC) standards IEC 60825-1 Edition 2.0 (2007) and IEC 60825-2 Edition 3.1 (2007). It is a Class I/1 laser optical fiber communication systems "product" under the IEC classifications. This product is designed to ensure that personnel operating the product are not endangered by laser radiation during normal operation and fault conditions. This product does not present a risk of eye injury because it is fully enclosed and does not contain embedded lasers greater than Class I/1 unless otherwise noted. CAUTION Laser hazard Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser radiation exposure. Do not view directly into the laser beam with optical instruments such as a fiber microscope because viewing of laser emission in excess of Class 1 limits significantly increases the risk of eye damage. Never look into the end of an exposed fiber or an open connector as long as the optical source is switched on. Ensure that the optical source is switched off before disconnecting optical fiber connectors. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-3 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements Canada .................................................................................................................................................................................................................................... Packaging collection and recovery requirements Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established. For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, please contact the Alcatel-Lucent Services Environmental Health and Safety organization. For installations not performed by Alcatel-Lucent Technologies, please contact the Alcatel-Lucent Customer Support Center at: Technical Support Services, within Canada: +1 630 224 4672, prompt 2 .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-4 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements European Union .................................................................................................................................................................................................................................... European Union Introduction The statements that follow are the product conformance statements that apply to the 9228 Base Station cabinet bearing the CE Marking and when deployed in the European Union. Declaration of Conformity for radio and telecommunication terminal equipment under the scope of Directive 1999/5/EC Hereby, Alcatel-Lucent declares that the equipment documented in this publication is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The technical documentation as required by the Conformity Assessment procedure is kept at the Alcatel-Lucent location which is responsible for this product. For more information please contact your local Alcatel-Lucent Customer Service Organization. CE marking This product has been CE-marked in accordance with the following European Directive: • Radio and Telecommunication Terminal Equipment (R&TTE) 1999/5/EC EMC and radio spectrum compliance for the 850 MHz product The equipment complies with the following EMC and radio spectrum specifications: • EN 300 339 V1.1.1 (1998-06) • • • • ETSI EN 301 489-1 V1.6.1 (2005-09) ETSI EN 301 489-26 V2.3.1 (2005-07) ETSI EN 301 908-1 V2.2.1 (2003-10) Code of Federal Regulations FCC part 24(E) • IS 3GPP2 - C.S0010-B Product safety conformance The equipment complies with the following product safety specifications: • • EN 60950-1:2001 EN 60215:1989 Telecommunications Standards The equipment complies with the following telecommunication specifications: • Technical Basis Regulation TBR 13 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-5 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements European Union .................................................................................................................................................................................................................................... Antenna exposure Antenna installations for the 9228 Base Station cabinet shall be performed in accordance with all applicable manufacturer's recommendations, and national laws and regulations. To ensure correct antenna installation, the antenna installer shall perform all necessary calculations and/or field measurements to evaluate compliance with applicable national laws or regulations regarding exposure to electromagnetic fields. The supplier of radio equipment, the supplier of antenna equipment and the integrator and builder of the site must provide sufficient information so that the limits of the exclusion zones can be determined. Any changes to the antenna or other equipment in the transmit path may require reevaluation of the exposures to electromagnetic fields. Pursuant to • • European Council Recommendation 1999/519/EC “On the limitation of exposure of the general public to electromagnetic fields” dated 12 July 1999 and ICNIRP (International Commission on Non-Ionising Radiation Protection) “Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields”, all installations must be evaluated against the Reference Levels, and if necessary exclusion zones for public and installation workers defined. The following information on Alcatel-Lucent supplied equipment is available from customer representatives: • • • • • Output power and antenna characteristic, if the product is equipped with an integral antenna. A detailed description of at least one typical normal configuration, including antenna system (feeders, connectors, combiners, antennas etc.), if the product is intended to be used with external antennas. Limit distances for general public and occupational exposure. If the product is intended for use with external antennas, limit distances shall be given for the given typical system configurations. Information how to specify exposure levels and limit distances for any optional system configuration not specified in detail. Information on how to install the equipment/system or the external antennas in order to ensure that the separation between the radiating antenna and general public are exceeding the maximum allowed distances. Information on the methodology used for the determination of RF safety compliance distances and exclusion zones, and the results of the compliance evaluation shall be available for inspection by officials of the governing authorities. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-6 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements European Union .................................................................................................................................................................................................................................... Optical transmitters Alcatel-Lucent declares that 9228 Base Station cabinet complies with the CENELEC standards EN 60825-1 Edition 1994 and its amendment 1 (2002) and amendment 2 (2001) and EN 60825-2 Edition 2004. It is a Class I/1 laser optical fiber communication systems “product” under the IEC classifications. This product is designed to ensure that personnel operating the product are not endangered by laser radiation during normal operation and fault conditions. This product does not present a risk of eye injury because it is fully enclosed and does not contain embedded lasers greater than Class I/1 unless otherwise noted. CAUTION Laser hazard Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser radiation exposure. Do not view directly into the laser beam with optical instruments such as a fiber microscope because viewing of laser emission in excess of Class 1 limits significantly increases the risk of eye damage. Never look into the end of an exposed fiber or an open connector as long as the optical source is switched on. Ensure that the optical source is switched off before disconnecting optical fiber connectors. Packaging collection and recovery requirements Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established. For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, please contact the Alcatel-Lucent Services Environmental Health and Safety organization. For installations not performed by Alcatel-Lucent Technologies, please contact the Alcatel-Lucent Customer Support Center at: Technical Support Services, from all other countries: +1 630 224 4672, prompt 2 .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-7 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements European Union .................................................................................................................................................................................................................................... Recycling / take-back / disposal of product Electronic products and batteries bearing or referencing the symbols shown below when put on the market within the European Union, shall be collected and treated at the end of their useful life, in compliance with applicable European Union and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product and batteries, such as heavy metals, the environment and human health may be negatively impacted as a result of inappropriate disposal. Note 1: For electronic products put on the market in the European Union, a solid bar under the crossed-out wheeled bin indicates that the product was put on the market after 13 August 2005. Note 2: For batteries put on the market in the European Union, a chemical symbol Hg (mercury), Cd (cadmium), or Pb (lead), or a combination of those symbols, beneath the cross-out wheeled bin indicates that the battery contains the corresponding heavy metals. Moreover, in compliance with legal requirements and contractual agreements, where applicable, Alcatel-Lucent will offer to provide for the collection and treatment of Alcatel-Lucent products bearing the logo at the end of their useful life, or products displaced by Alcatel-Lucent equipment offers. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-8 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements European Union .................................................................................................................................................................................................................................... For information regarding take-back, recycling, or disposal of equipment by Alcatel-Lucent or for equipment take-back requests, visit the Alcatel-Lucent Take-Back web page (http://www.alcatel-lucent.com/product_takeback), or contact Alcatel-Lucent Takeback Support at takeback@alcatel-lucent.com. For technical information on product treatment, consult the Alcatel-Lucent Recycling Information web page (http://www.alcatel-lucent.com/product_recycling) Material content compliance European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent chromium, and certain flame retardants in electrical and electronic equipment. This Directive applies to electrical and electronic products placed on the EU market after 1 July 2006, with various exemptions, including an exemption for lead solder in network infrastructure equipment. Alcatel-Lucent products shipped to the EU after 1 July 2006 comply with the EU RoHS Directive. .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-9 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements United States .................................................................................................................................................................................................................................... United States Introduction The statements that follow are the product conformance statements that apply to the 9228 Base Station cabinet when deployed in the United States. Federal Communications Commission Important! Changes or modifications not expressly approved by Alcatel-Lucent, Inc. could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part 15 Class A (as marketed) Important! This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protections against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's expense. FCC Part 15 Class B (as marketed) Important! This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-10 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements United States .................................................................................................................................................................................................................................... FCC Part 68 This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the cabinet assembly of this equipment is a label that contains, among other information, a product identifier in the format of AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. • • FIC 04DU9-1SN SOC 6.0N The T1 network interface on this equipment is hard wired to a punch down block , which meets the FCC specifications. If this equipment 9228 Base Station cabinet causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. However, if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. FCC regulations prohibit the connection of customer-provided equipment to central office implemented systems. Connection to party lines is subject to tariffs; users should contact their state public utility commission, public service commission, or corporation commission for information. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. If trouble is experienced with this equipment repair or warranty information may be obtained by contacting: Technical Support Services, within the United States: +1 630 224 4762, prompt 2 RF approval This equipment complies with Part 2, Subpart J - Equipment Authorization Procedures, of the FCC Rules. This device complies with Part 22 - Public Mobile Services, Subpart H - Cellular Radiotelephone Services This equipment complies with Part 24 - Personal Communications Services, Subpart E Broadband PCS. This equipment complies with Part 27 - Miscellaneous Wireless Communications Services .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-11 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012 Product conformance statements United States .................................................................................................................................................................................................................................... FDA/IEC optical transmitter product compliance Alcatel-Lucent declares that 9927 Distributed Base Station cabinet complies with the Food and Drug Administration's Center for Devices and Radiological Health (FDA/CDRH) regulations 21 CFR 1040.10 and 1040.11. It is a Class I/1 laser optical fiber communication systems "product" under the FDA. This Product is designed to ensure that personnel operating the product are not endangered by laser radiation during normal operation and fault conditions. This product does not present a risk of eye injury because it is fully enclosed and does not contain embedded lasers greater than Class I/1 unless otherwise noted. CAUTION Laser hazard Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser radiation exposure. Do not view directly into the laser beam with optical instruments such as a fiber microscope because viewing of laser emission in excess of Class 1 limits significantly increases the risk of eye damage. Never look into the end of an exposed fiber or an open connector as long as the optical source is switched on. Ensure that the optical source is switched off before disconnecting optical fiber connectors. Product safety conformance The 9228 Base Station cabinet is Safety Certified ITE by Underwriters Laboratory (UL) and UL Canada. This Certification is marked on the equipment main nameplate label. Should the local Authority Having Jurisdiction (AHJ) require prior or additional verification of this Certification, a Product Certificate of Compliance can be obtained from the specific Certification Body by the Business/Product Unit Applicant for the product or by contacting: Technical Support Services, within the United States: +1 630 224 4762, prompt 2 Any modifications to this equipment are not permitted without review and official written authorization from the specific Certification Body. Unauthorized changes may violate the Product Safety Certification. Modifications or changes authorized by official CN/CNN are assumed to have received prior approval from this Lab. .................................................................................................................................................................................................................................... Alcatel-Lucent – Proprietary 9927 Dist BTS Outdoor G-12 Use pursuant to applicable agreements 401-703-516 Issue 1 March 2012 Product conformance statements United States .................................................................................................................................................................................................................................... Antenna exposure Antenna installations for the 9927 Distributed Base Station cabinet shall be performed in accordance with all applicable manufacturer's recommendations, and national laws and regulations. To ensure correct antenna installation, the antenna installer shall perform all necessary calculations and/or field measurements to evaluate compliance with applicable national laws or regulations regarding exposure to electromagnetic fields. The supplier of radio equipment, the supplier of antenna equipment and the integrator and builder of the site must provide sufficient information so that the limits of the exclusion zones can be determined. Any changes to the antenna or other equipment in the transmit path may require reevaluation of the exposures to electromagnetic fields. Pursuant to 47 CFR Part 1, Subpart I, subject to the provisions of section 1.1307, all installations must be evaluated for requirements contained in Table 1, “Limits for maximum permissible exposure,” in section 1.1310. Packaging collection and recovery requirements Countries, states, localities, or other jurisdictions may require that systems be established for the return and/or collection of packaging waste from the consumer, or other end user, or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the return and/or collection of the packaging waste may be established. For more information regarding collection and recovery of packaging and packaging waste within specific jurisdictions, please contact the Alcatel-Lucent Services Environmental Health and Safety organization. For installations not performed by Alcatel-Lucent Technologies, please contact the Alcatel-Lucent Customer Support Center at: Technical Support Services, within the United States: +1 630 224 4762, prompt 2 Material content compliance The following notification applies to Alcatel-Lucent products distributed for sale, resale or use. This product, part, or both may include a lithium-manganese dioxide battery, which contains very small amounts of a perchlorate substance. Special handling may apply. For California: Perchlorate Material - special handling may apply. See http://www.dtsc.ca.gov/hazardouswaste/perchlorate/ .................................................................................................................................................................................................................................... 9927 Dist BTS Outdoor Alcatel-Lucent – Proprietary G-13 401-703-516 Use pursuant to applicable agreements Issue 1 March 2012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : qy Create Date : 2012:03:22 12:06:32-04:00 Modify Date : 2012:03:22 12:15:42-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2012:03:22 12:15:42-04:00 Producer : Acrobat Distiller 9.2.0 (Windows) Format : application/pdf Title : Microsoft Word - RRH PCS_UserMan_exh3.doc Creator : qy Document ID : uuid:a54a636d-0476-48e5-a9d1-cb53d40ecc28 Instance ID : uuid:c1c0d0bd-acf1-4d0f-971b-aa54e8b934a5 Page Count : 247EXIF Metadata provided by EXIF.tools