Nokia of America BBTRX-13 LTE TRDU2X120-AWS User Manual

Alcatel-Lucent USA Inc. LTE TRDU2X120-AWS

Exhibit D Users Manual per 2 1033 c3

 AWS TRDU List10  Installation Guide Issue: 1.0.0    1/14 PMC CONFIDENTIAL         Users Manual Section 2.1033 (C) (3)
 AWS TRDU List10  Installation Guide Issue: 1.0.0    2/14 PMC CONFIDENTIAL       AWS TRDU List10 Installation Guide  Product Name : AWS (Band Class 4) TRDU, KS-24841 List 10 Model Number : 849172416       Issue: 1.0.0 Date; February 14, 2013
 AWS TRDU List10  Installation Guide Issue: 1.0.0    3/14 PMC CONFIDENTIAL  Revison History Issue No. Description Date 1.0.0 First edition February 14, 2013
 AWS TRDU List10  Installation Guide Issue: 1.0.0    4/14 PMC CONFIDENTIAL  Table of Contents Revison History ..................................................................................................................................... 3 Table of Contents ................................................................................................................................... 4 1 INTRODUCTION ............................................................................................................................. 5 1.1 System Overview ...................................................................................................................... 5 1.2 Equipment Outline .................................................................................................................... 6 1.3 Structural Outline ...................................................................................................................... 7 1.4 Specification ............................................................................................................................. 8 1.4.1 System Specification .......................................................................................................... 8 1.4.2 Optical Module Specification .............................................................................................. 9 1.4.3 AWS TRDU Specification ................................................................................................. 10 2 Installing the TRDU ....................................................................................................................... 11 2.1 Appearance ............................................................................................................................ 11 2.2 User Interface ......................................................................................................................... 12 2.3 Status LED ............................................................................................................................. 13 3 FCC WARING ............................................................................................................................... 14
 AWS TRDU List10  Installation Guide Issue: 1.0.0    5/14 PMC CONFIDENTIAL  1  INTRODUCTION  1.1 System Overview  AWS TRDU List10 connect with BBU which made by Alcatel-Lucent.  AWS TRDU is transiver system which is support LTE fuction in AWS frequency band range.      AWS TRDU is connected by optical cable. CPRI Interface of one AWS TRDU List10 connect to BBU (LTE)       Figure 1-1 System Overview  LTE BBU     AWS-TRDU      CPRI AWS-TRDU AWS-TRDU TRDU shelf CPRI CPRI
 AWS TRDU List10  Installation Guide Issue: 1.0.0    6/14 PMC CONFIDENTIAL  1.2 Equipment Outline     Figure 1-2 Equipment Outline  ① Execute transmit and receive BBU and UL/DL Digital Signal by optical interface ② Enable to maintain TRDU with  OCI (On site Configuration Interface) and Personal Computer.   ③ Enable to use Alarm-interface detect function   ④ AISG supply and control power function which is connected to tower-top  equipment from TRDU. ⑤ This system support    DC -48V power input ⑥ Execute several functions (Status-Control/Tranciver-Control/Mesurement/Failure -Control…) based on control message of BBU. ⑦ Enable to download Software (Control Software, DSP Firmware、FPGA Data) as   remotely    AWS-TRDU  BBU         Tower-top Equipment               Monitor   OCI Ether net  CPRI AISG I2C DC-48V OCI Serial(telnet)
 AWS TRDU List10  Installation Guide Issue: 1.0.0    7/14 PMC CONFIDENTIAL  1.3 Structural Outline  【Structure Outline】 ① Thermal method is air‐cooled engine(TRDU has no cooling fan) ② Enable to load next cable (Power Cable/Optical Cable/AISG Cable/ Antenna Cable /AUX Cable) from Front side of the TRDU. ③ There are LED in front side of the TRDU which can monitoring system status.
 AWS TRDU List10  Installation Guide Issue: 1.0.0    8/14 PMC CONFIDENTIAL  1.4 Specification  1.4.1 System Specification  No Item Content   Remark   1 Input Power   -48V (-37V~-57V)  2 Power Consumption   Less than 650W    3 Weight Less than 15kg  4 Temperature range   -40~+60℃  5 Humidity range 5~95%  6 Dimension Width  110 mm Height   355 mm( not include guide rail ) Depth  360 mm  7 Thermal Type   naturally air cooled engine    8 Setting Location   Inside
 AWS TRDU List10  Installation Guide Issue: 1.0.0    9/14 PMC CONFIDENTIAL  1.4.2 Optical Module Specification   No Item Condition/etc   Remark   1  Optical Center Length   <Primary port> DL:1550 nm、UL:1310 nm <Secondary port> Mix mode:1550 nm/1310 nm  2  Bit Rate <Primary port> 1.2288 Gbps~6.1440 Gbps <Secondary port> 2.4576 Gbps~6.144 Gbps  3  Transmission Distance <Primary port> Maximum 20 km <Secondary port> Maximum 50m
 AWS TRDU List10  Installation Guide Issue: 1.0.0    10/14 PMC CONFIDENTIAL  1.4.3 AWS TRDU Specification  No Item   Type Remark 1 Support Technologies   LTE  2 RF Output Power   67W/Branch×2 134W/Branch×1  3 Downlink RF Frequency   2110 MHz –2155 MHz  4 Uplink RF Frequency     1710 MHz –1755 MHz  5 Number of Carrier   LTE :4Carriers×2
 AWS TRDU List10  Installation Guide Issue: 1.0.0    11/14 PMC CONFIDENTIAL  2  Installing the TRDU  2.1 Appearance                                     Figure 2-1 Appearance of the TRDU with connector covers 4-φ5.5 holes for Equipment mounting   and Ground Lugs (There are 2-φ5.5 holes on opposite side)
 AWS TRDU List10  Installation Guide Issue: 1.0.0    12/14 PMC CONFIDENTIAL  2.2 User Interface      Figure 2-2 User Interface   Table 2-1 Connectors, LED, Reset button etc.                          No. Connector Name Connector Type and Comment 1  TX/RX 1 7/16 DIN F 2 TX/RX 2 7/16 DIN F 3  TX1 Mon DIN 1.0/2.3 F 4 TX2 Mon DIN 1.0/2.3 F 5  AUX RX1 DIN 1.0/2.3 F 6 AUX RX2 DIN 1.0/2.3 F 7  CPRI PRI SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 8  CPRI SEC SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 9  ALD Female 8-pin circular connector, per IEC 60130-9 10 DC -48V IN 2W2 2-pin D-sub   circular connector Amphenol P-FCE17-E2W2SB-FN5-RevB 11 ETH(Ethernet) RJ 45 12 I2C RJ 45 13 Serial Port  4-pin Firewire socket, per IEEE1394 14 Reset Button - 15 Status LED  - (1) (2) (5) (6) (7) (8) (15) (10) (11) (12) (13) (9) (3) (4) (14)
 AWS TRDU List10  Installation Guide Issue: 1.0.0    13/14 PMC CONFIDENTIAL  2.3  Status LED  Table 2-2 LED Display States No. State Green LED Yellow LED Red LED 1 No Power Supplied Off Off Off 2 Initial Power On Solid Solid Solid 3 Normal Operation Solid Off Off 4 Standby Off Solid Off 5 Critical HW Failure Off Off Solid 6 Partial or Non-Critical Failure Solid Off Solid 7 Tmporary HW Critical Fault Off Off Flash 8 Slave CPRI Link External Failure Off Solid Solid 9 External Antenna Failure Solid Off Flash 10 Software Download Off Flash Off 11 Background Software Download Solid Flash Off 12 External Power Supply Failure Flash Flash Flash 13 Reset Button Solid Solid Solid
 AWS TRDU List10  Installation Guide Issue: 1.0.0    14/14 PMC CONFIDENTIAL  3  FCC WARNING  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Properly shielded and grounded cables and connectors must be used for connection to host computers and / or peripherals in order to meet FCC emission limits.  Data transmission is always initiated by software, which is the passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinue transmission in case of either absence of information to transmit or operational failure.  FCCPart15: This device complies with Part15 of the FCC Rules. Operation is subject to the condition that thisdevice does not cause harmful interference.      RF approval: This equipment complies with Part 2, Subpart J – Equipment Authorization   Procedures, of the FCC Rules.    This device complies with Part 27-  MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES, Subpart 27.53 (h)