Nokia of America BBTRX-13 LTE TRDU2X120-AWS User Manual
Alcatel-Lucent USA Inc. LTE TRDU2X120-AWS
Exhibit D Users Manual per 2 1033 c3
AWS TRDU List10 Installation Guide Issue: 1.0.0 Users Manual Section 2.1033 (C) (3) 1/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 AWS TRDU List10 Installation Guide Product Name : AWS (Band Class 4) TRDU, KS-24841 List 10 Model Number : 849172416 Issue: 1.0.0 Date; February 14, 2013 2/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 Revison History Issue No. 1.0.0 Description First edition Date February 14, 2013 3/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 Table of Contents Revison History ..................................................................................................................................... 3 Table of Contents ................................................................................................................................... 4 1 INTRODUCTION ............................................................................................................................. 5 1.1 System Overview ...................................................................................................................... 5 1.2 Equipment Outline .................................................................................................................... 6 1.3 Structural Outline ...................................................................................................................... 7 1.4 Specification ............................................................................................................................. 8 1.4.1 System Specification .......................................................................................................... 8 1.4.2 Optical Module Specification .............................................................................................. 9 1.4.3 AWS TRDU Specification ................................................................................................. 10 2 Installing the TRDU ....................................................................................................................... 11 2.1 Appearance ............................................................................................................................ 11 2.2 User Interface ......................................................................................................................... 12 2.3 Status LED ............................................................................................................................. 13 3 FCC WARING ............................................................................................................................... 14 4/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 INTRODUCTION 1.1 System Overview AWS TRDU List10 connect with BBU which made by Alcatel-Lucent. AWS TRDU is transiver system which is support LTE fuction in AWS frequency band range. AWS TRDU is connected by optical cable. CPRI Interface of one AWS TRDU List10 connect to BBU (LTE) CPRI AWS-TRDU LTE BBU CPRI AWS-TRDU CPRI AWS-TRDU TRDU shelf Figure 1-1 System Overview 5/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 1.2 Equipment Outline OCI Serial(telnet) OCI Ether net DC-48V Monitor BBU CPRI AWS-TRDU I2C AISG Tower-top Equipment Figure 1-2 Equipment Outline ① ② ③ ④ ⑤ ⑥ ⑦ Execute transmit and receive BBU and UL/DL Digital Signal by optical interface Enable to maintain TRDU with OCI (On site Configuration Interface) and Personal Computer. Enable to use Alarm-interface detect function AISG supply and control power function which is connected to tower-top equipment from TRDU. This system support DC -48V power input Execute several functions (Status-Control/Tranciver-Control/Mesurement/Failure -Control…) based on control message of BBU. Enable to download Software (Control Software, DSP Firmware、FPGA Data) as remotely 6/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 1.3 Structural Outline 【Structure Outline】 ① Thermal method is air‐cooled engine(TRDU has no cooling fan) ② Enable to load next cable (Power Cable/Optical Cable/AISG Cable/ Antenna Cable /AUX Cable) from Front side of the TRDU. ③ There are LED in front side of the TRDU which can monitoring system status. 7/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 1.4 Specification 1.4.1 System Specification No Item Content Remark Input Power Power Consumption Weight Temperature range Humidity range Dimension Thermal Type Setting Location -48V (-37V~-57V) Less than 650W Less than 15kg -40~+60℃ 5~95% Width 110 mm Height 355 mm( not include guide rail ) Depth 360 mm naturally air cooled engine Inside 8/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 1.4.2 Optical Module Specification No Item Optical Center Length Bit Rate Transmission Distance Condition/etc Remark <Primary port> DL:1550 nm、UL:1310 nm <Secondary port> Mix mode:1550 nm/1310 nm <Primary port> 1.2288 Gbps~6.1440 Gbps <Secondary port> 2.4576 Gbps~6.144 Gbps <Primary port> Maximum 20 km <Secondary port> Maximum 50m 9/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 1.4.3 AWS TRDU Specification No Item Type Remark Support Technologies RF Output Power Downlink RF Frequency Uplink RF Frequency Number of Carrier LTE 67W/Branch×2 134W/Branch×1 2110 MHz –2155 MHz 1710 MHz –1755 MHz LTE :4Carriers×2 10/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 Installing the TRDU 2.1 Appearance 4-φ5.5 holes for Equipment mounting and Ground Lugs (There are 2-φ5.5 holes on opposite side) Figure 2-1 Appearance of the TRDU with connector covers 11/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 2.2 User Interface (10) (12) (1) (9) (4) (14) (15) (11)(13) (7) (5) (6) (3) (8) (2) Figure 2-2 User Interface Table 2-1 Connectors, LED, Reset button etc. No. Connector Name Connector Type and Comment TX/RX 1 7/16 DIN F TX/RX 2 7/16 DIN F TX1 Mon DIN 1.0/2.3 F TX2 Mon DIN 1.0/2.3 F AUX RX1 DIN 1.0/2.3 F AUX RX2 DIN 1.0/2.3 F CPRI PRI CPRI SEC ALD Female 8-pin circular connector, per IEC 60130-9 10 DC -48V IN 2W2 2-pin D-sub circular connector Amphenol P-FCE17-E2W2SB-FN5-RevB 11 ETH(Ethernet) RJ 45 12 I2C RJ 45 13 Serial Port 4-pin Firewire socket, per IEEE1394 14 Reset Button 15 Status LED SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 12/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 2.3 Status LED Table 2-2 LED Display States No. State Green LED Yellow LED Red LED 10 11 12 13 No Power Supplied Initial Power On Normal Operation Standby Critical HW Failure Partial or Non-Critical Failure Tmporary HW Critical Fault Slave CPRI Link External Failure External Antenna Failure Software Download Background Software Download External Power Supply Failure Reset Button Off Solid Solid Off Off Solid Off Off Solid Off Solid Flash Solid Off Solid Off Solid Off Off Off Solid Off Flash Flash Flash Solid Off Solid Off Off Solid Solid Flash Solid Flash Off Off Flash Solid 13/14 PMC CONFIDENTIAL AWS TRDU List10 Installation Guide Issue: 1.0.0 FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Properly shielded and grounded cables and connectors must be used for connection to host computers and / or peripherals in order to meet FCC emission limits. Data transmission is always initiated by software, which is the passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinue transmission in case of either absence of information to transmit or operational failure. FCCPart15: This device complies with Part15 of the FCC Rules. Operation is subject to the condition that thisdevice does not cause harmful interference. RF approval: This equipment complies with Part 2, Subpart J – Equipment Authorization Procedures, of the FCC Rules. This device complies with Part 27- MISCELLANEOUS WIRELESS COMMUNICATIONS SERVICES, Subpart 27.53 (h) 14/14 PMC CONFIDENTIAL
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : kawasaki Create Date : 2013:09:18 21:59:27-04:00 Modify Date : 2013:09:18 21:59:30-04:00 Subject : ハードウェア設計書 Tag : 株式会社ウェステック Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2013:09:18 21:59:30-04:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Document ID : uuid:7076b50e-a928-4fcc-95d3-6fabe9432843 Instance ID : uuid:b0252594-8da0-4128-a816-45d7cb2ca24d Format : application/pdf Title : 設計書 Description : ハードウェア設計書 Creator : kawasaki Producer : Adobe PDF Library 10.0 Keywords : Source Modified : D:20130919015909 Company : 株式会社ウェステック Manager : Comments : Tag : 株式会社ウェステック Headline : ㅑㅼㅛ㇦㇧㇢è¨�è¨‹æł¸ Page Layout : OneColumn Page Count : 14EXIF Metadata provided by EXIF.tools