GTO Access Systems, LLC GATE EDGE Transmitter

User Manual

The SGET is part of Linear PRO Access control product line. In a typical installation, the SGET is mounted on a motorized gate, door or barrier arm and wired to a 10K exterior safety edge sensor which presents a closed circuit across the connecting wires when an object is hit during the closing of a gate. To insure full compatibility with all gate edge supervision features, Linear recommends Miller gate edge sensors with 10K only. Please specify when ordering sensor. If the edge sensor is pressed for 1/4 second, the SGET transmits a message to the SGER to reverse the movement of the gate. The SGET circuit board has been coated to prevent moisture damage and is mounted inside a weather resistant berglass box. The mounting box attaches to the gate through sealed interior mounting screws.TYPICAL INSTALLATIONLoosen the four screws on transmitter top and remove cover. Install 2 “C” size batteries at this time.Refer to diagram below for transmitter parts location and details. Mount safety edge according to manufacturer’s instructions included with the product.Choose a location as high as possible on gate in a secure position. Use the template attached to mark the location for the transmitter. You may have to attach a metal or wood plate to mount transmitter. Use a 3/32” bit and drill holes. Attach SGET to gate using the four #6 self-tapping drill point screws.Unscrew the cable grip about 3/4 of the way and thread the safety edge cable through the cable entry on the transmitter.Attach safety edge cable to terminals as shown. Tighten cable grip assembly using pliers to assure a water tight seal.SGETDIGITAL GATE TransmitterInstallation InstructionsPRO ACCESSTMLinear PRO Access • 3121 Hartseld Road • Tallahassee, FL 323031.800.543.4283 • linearproaccess.comDescriptionSTEP 2     Remove Cover and Install BatteriesSTEP 4     Mount SGET STEP 5     Assemble Cable Grip STEP 6      Attach CableSTEP 1     Locate Parts STEP 3    Mount Safety EdgeREMOVECOVERINSTALL“C” BATTERIESSGETTRANSMITTERSAFETY EDGESENSOR GATEOPERATORCABLE GRIPASSEMBLYTO SAFETYEDGETO SAFETYEDGEATTACH EDGESENSOR CABLETO TERMINALS1.77”3.88”WELD PLATETO GATEATTACH SGETTO GATEINSTALLSAFETY EDGE“C” SizeBattery HoldersProgramming ButtonAntennaWireTerminalsPRINTERS INSTRUCTIONS  INSTR,INSTL,SGER SERIES - GTO P/N: 10016915 - INK:  BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” -  SCALE: 1-1 - SIDE 1 of 2
Test safety edge connection by pressing the safety edge. The SGET alarm will beep 4 times.Refer to receiver programming instructions to set the receiver into the program mode. Press the button to program the unit identication code into the receiver. Replace transmitter cover.Activate the gate to close.  As the gate is closing, press the safety edge with your hand.  Gate should stop and reverseRemove the transmitter cover and remove old batteries.  Replace two “C” batteries and replace transmitter cover.STEP 7  Test Safety EdgeSTEP 10   Test SystemSTEP 8  Program Transmitter STEP 9  Close TransmitterSTEP 11  Replacing BatteriesThis Linear PRO Access (LPA) product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from LPA or through LPA’s normal distribution channels. LPA does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of LPA for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This LPA Warranty is in lieu of all other warranties express or implied.All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact LPA Technical Services at 1-800-543-1236 for an RPA# and other important detailsLinear PRO Access radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.Copyright© 2017 GTO Access Systems, LLCDocument Number:  10016915 REV A (05-15-17)LIMITED WARRANTY IMPORTANTREMOVE/REPLACE COVERREMOVE/REPLACE“C” BATTERIESPRESSEDGECLOSE GATEREPLACE COVERCAUTION: DO NOT STAND IN THE PATH OF THE CLOSING GATE.PRESS THE PROGRAMMINGBUTTONSGERPRESS EDGEWITH HANDTroubleshootingSGET  Alarm  Fault?   Condition CodeLow Batt  1  NO  Low BatteryOpen  2  YES  Edge not presentNo Ack  3  YES  SGET not able to send message (dead or too        far away)Edge  4  YES  Edge shortedPRINTERS INSTRUCTIONS  INSTR,INSTL,SGER SERIES - GTO P/N: 10016915 - INK:  BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” -  SCALE: 1-1 - SIDE 2 of 2WARNING: Changes, modications or adjustments not expressly approved by GTO Access Systems, LLC could void the user’s authority to operate this equipment. There Are No User Serviceable Parts.NOTICE: This device complies with part 15 of the FCC rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the deviceLe présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Navigation menu