Nortek Security and Control GTO Access SGET GATE EDGE Transmitter User Manual
GTO Access Systems, LLC GATE EDGE Transmitter
User Manual
PRINTERS INSTRUCTIONS INSTR,INSTL,SGER SERIES - GTO P/N: 10016915 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 1 of 2 TYPICAL INSTALLATION Description PRO ACCESS The SGET is part of Linear PRO Access control product line. In a typical installation, the SGET is mounted on a motorized gate, door or barrier arm and wired to a 10K exterior safety edge sensor which presents a closed circuit across the connecting wires when an object is hit during the closing of a gate. To insure full compatibility with all gate edge supervision features, Linear recommends Miller gate edge sensors with 10K only. Please specify when ordering sensor. If the edge sensor is pressed for 1/4 second, the SGET transmits a message to the SGER to reverse the movement of the gate. TM SGET DIGITAL GATE Transmitter The SGET circuit board has been coated to prevent moisture damage and is mounted inside a weather resistant fiberglass box. The mounting box attaches to the gate through sealed interior mounting screws. Installation Instructions SAFETY EDGE SENSOR Linear PRO Access • 3121 Hartsfield Road • Tallahassee, FL 32303 1.800.543.4283 • linearproaccess.com STEP 1 SGET TRANSMITTER STEP 2 Locate Parts Refer to diagram below for transmitter parts location and details. Remove Cover and Install Batteries STEP 3 Loosen the four screws on transmitter top and remove cover. Install 2 “C” size batteries at this time. GATE OPERATOR Mount Safety Edge Mount safety edge according to manufacturer’s instructions included with the product. INSTALL SAFETY EDGE “C” Size Battery Holders REMOVE COVER Programming Button Antenna Wire INSTALL “C” BATTERIES Terminals STEP 4 Mount SGET STEP 5 Choose a location as high as possible on gate in a secure position. Use the template attached to mark the location for the transmitter. You may have to attach a metal or wood plate to mount transmitter. Use a 3/32” bit and drill holes. Attach SGET to gate using the four #6 self-tapping drill point screws. Assemble Cable Grip STEP 6 Unscrew the cable grip about 3/4 of the way and thread the safety edge cable through the cable entry on the transmitter. Attach Cable Attach safety edge cable to terminals as shown. Tighten cable grip assembly using pliers to assure a water tight seal. WELD PLATE TO GATE 1.77” TO SAFETY EDGE 3.88” ATTACH SGET TO GATE CABLE GRIP ASSEMBLY TO SAFETY EDGE ATTACH EDGE SENSOR CABLE TO TERMINALS PRINTERS INSTRUCTIONS INSTR,INSTL,SGER SERIES - GTO P/N: 10016915 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - SIDE 2 of 2 STEP 7 Test Safety Edge STEP 8 Program Transmitter STEP 9 Close Transmitter Test safety edge connection by pressing the safety edge. The SGET alarm will beep 4 times. Refer to receiver programming instructions to set the receiver into the program mode. Press the button to program the unit identification code into the receiver. Replace transmitter cover. REPLACE COVER PRESS EDGE WITH HAND SGER PRESS THE PROGRAMMING BUTTON STEP 10 Test System STEP 11 Replacing Batteries Troubleshooting Activate the gate to close. As the gate is closing, press the safety edge with your hand. Gate should stop and reverse Remove the transmitter cover and remove old batteries. Replace two “C” batteries and replace transmitter cover. SGET CAUTION: DO NOT STAND IN THE PATH OF THE CLOSING GATE. REMOVE/REPLACE COVER REMOVE/REPLACE “C” BATTERIES PRESS EDGE Alarm Fault? Code Condition Low Batt 1 NO Low Battery Open YES Edge not present No Ack 3 YES SGET not able to send message (dead or too far away) Edge Edge shorted YES CLOSE GATE LIMITED WARRANTY IMPORTANT This Linear PRO Access (LPA) product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from LPA or through LPA’s normal distribution channels. LPA does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of LPA for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This LPA Warranty is in lieu of all other warranties express or implied. Linear PRO Access radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact LPA Technical Services at 1-800-543-1236 for an RPA# and other important details WARNING: Changes, modifications or adjustments not expressly approved by GTO Access Systems, LLC could void the user’s authority to operate this equipment. There Are No User Serviceable Parts. NOTICE: This device complies with part 15 of the FCC rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Copyright© 2017 GTO Access Systems, LLC Document Number: 10016915 REV A (05-15-17)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c138 79.159824, 2016/09/14-01:09:01 Create Date : 2017:05:17 10:41:03-04:00 Metadata Date : 2017:05:17 10:41:05-04:00 Modify Date : 2017:05:17 10:41:05-04:00 Creator Tool : Adobe InDesign CC 2017 (Macintosh) Instance ID : uuid:6a7ff991-bd3d-e840-8120-3703b0935019 Original Document ID : xmp.did:65b8a009-434b-4cec-a2c9-638aa80c70f6 Document ID : xmp.id:21b20576-8d88-4d70-b725-79fc6261030d Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:5372e0e6-a02c-47ae-a001-753c5931a50c Derived From Document ID : xmp.did:5e1f0c67-c8ea-4cea-a474-a4b0a49f6764 Derived From Original Document ID: xmp.did:65b8a009-434b-4cec-a2c9-638aa80c70f6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Macintosh) History Changed : / History When : 2017:05:17 10:41:03-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2017 (Macintosh)EXIF Metadata provided by EXIF.tools