Nortek Security and Control 00170 Grill Guard User Manual GC GRILL1 B 345 10017336 X16 indd
Nortek Security & Control LLC Grill Guard GC GRILL1 B 345 10017336 X16 indd
User Manual
PRINTER’S INSTRUCTIONS: INSTR,INSTL GC-GRILL1-B-345 - P/N: 10017336 X16 INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 6.000” X 9.000” - TOL: +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5” x 2.25” - FINISH WITH LOGO SHOWING - SIDE 1 OF 2 GC-GRILL1-B-345 GRILL GUARD INSTALLATION INSTRUCTIONS The GoControl® Grill Guard (device) is a contact ON/OFF sensor that alerts your security panel (and op onally the smartphone with Alarm.com) when the knob on a grill/stove is turned ON. It is compa ble with 2GIG security panels, including GC2, GC3, and Vario. 5. Install the sleeve onto the knob stem, following the orienta on, as shown in Step 4. Note: Ensure the bo om of the sleeve magnet has a clearance of 0.1 inches from the knob panel surface. GRILL KNOB SLEEVE MAGNET DISC INNER MARKS 6. Remove the Signal Suppression Tape from the disc to ac vate the sensor located inside the disc. ADHESIVE STRIPS KNOB STEM Figure 1. Grill Knob Device Assembly SIGNAL SUPPRESSION TAPE Contents Verify that the package contains the following: • One (1) Grill Guard disc - w/ pre-installed ba eries and adhesive strips a ached • Knob stem sleeves w/magnets – 3 different sizes Pre-Installation Checks Before installa on: 1. Ensure the device (grill, stove, heater, etc.) is turned OFF. If possible, also turn OFF the gas valve and/or the power source. 2. Ensure the grill/stove surface around the knob is flat, enabling the disc to be a ached. 3. If a trim ring around the knob is on the surface, ensure the inner diameter of the ring is no smaller than 2.5 inches. 4. Ensure the knob stem has adequate length for allowing inser ng the Grill Guard disc on the knob at least 0.2 inches above its usual “all-the-way-in” posi on on the knob stem, allowing the grill knob to operate properly. Installation 1. Ensure the knob where you are installing the Grill Guard is turned to the OFF posi on. 2. Remove the knob from the grill/stove. Note: If necessary, remove the knob trim ring. 3. Ensure the grill/stove surface around the knob area is clean. 4. Iden fy the sleeve that best fits your knob stem, from the three provided. 1. 2. 3. Notes: • The sleeve orienta on for your grill/stove knob stem may require flipping a sleeve over. • If the knob stem protrudes too far, try using the cavity-backed sleeve (3.). • If the sleeve or knob has a loose fit or the sensor alignment is off, use a small amount of duct tape or electrical tape to make it snug. Copyright © 2017 Nortek Security & Control LLC 7. Remove the visible protec ve backing material from each adhesive strip. 8. Align the inner marks on the disc with the magnet on the sleeve and mount the disc to the grill/stove face. SLEEVE INNER MARKS MAGNET 9. Install the grill knob back onto the knob stem. 10.Use your Panel to program the Grill Guard. Programming the Device on the GC2/GC2 Panel For GC2 and GC3 panels, program the Grill Guard on your 2GIG panel with the following parameters. (Please refer to your panel’s quick programming guide for the actual steps.) Sensor Type: (23) No Response Type Sensor Equipment Type: Contact Equipment Code: (0862) 2GIG Thin Door/Window Contact1 Serial Number: [Input the unique 7-digit TXID.]2 Equipment Age: New Sensor Loop Number: 2 Dialer/Transmission Delay: Enabled Voice Descriptor: GAS LEFT ON3 Sensor Reports: Enabled Sensor Supervised: Disabled4 Sensor Chime: [User-specified] This is a provisional Equipment Code. A new category called “Grill Guard” (or similar name) will be added in a future GC2/GC3 panel update. Alterna vely, a Grill Guard can be automa cally learned in. This is a recommended voice descriptor. The user may define a custom voice descriptor, as needed. Choose Disabled if the user plans on taking the grill/stove away from the premises from me to me. Otherwise, choose Enabled. PRINTER’S INSTRUCTIONS: INSTR,INSTL GC-GRILL1-B-345 - P/N: 10017336 X16 INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 6.000” X 9.000” - TOL: +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5” x 2.25” - FINISH WITH LOGO SHOWING - SIDE 2 OF 2 Programming the Device on the Vario Panel Specifications For the Vario panel, a er learning in1 the Grill Guard, please configure the zone the Grill Guard is in with the following parameters: Zone Type: Output Trigger Zone Sound Armed Away: Silent Zone Sound Armed Stay: Silent Zone Sound Disarmed: Chime or Silent If you want to manually program the Grill Guard in the Vario panel using the TXID, convert the GC2/GC3 TXID, as follows, to obtain the Vario TXID. Example: GC2/GC3 TXID = 080-9665, Vario TXID = 809,665 + 11,602,097,152 = 11,602,906,817 Setting up E-mail Notification – Alarm.com Accounts Only 1. Navigate to hƩp://www.alarm.com and click LOGIN. 2. Your systems dashboard page will appear. Select the Security tab and click Sensors. 3. Iden fy the new sensor you added. You can rename the Sensor Name. When finished, click Save. • • • • Signal Range: 100 . open-air from a 2GIG panel Transmission Frequency: 345 MHz Disc dimensions: 2.2” diameter, 0.21” thickness Opera ng Temperature: 14°F to 167°F (-10°C to 75°C) FCC & IC Notice This device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s). Opera on is subject to the following two condi ons: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference received that may cause undesired opera on. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploita on est autorisée aux deux condi ons suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’u lisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscep ble d’en comprome re le fonc onnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons may cause harmful interference to radio communica ons. However, there is no guarantee that interference will not occur in a par cular installa on. If this equipment does cause harmful interference to radio or television recep on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separa on between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician to help. WARNINGS: • Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. • The Grill Guard is not intended as a life-safety device. It is not intended to replace any other safety considerations. Limited Warranty 4. Click the NoƟficaƟons tab, and then +New NoƟficaƟon bu on to create a new event. The menu will appear with the Standard tab open by default. This Nortek Security & Control product is warranted against defects in material and workmanship for 6 months. Nortek Security & Control does not warrant this product to consumers. There are no obliga ons or liabili es on the part of Nortek Security & Control for consequen al damages arising out of or in connec on with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installa on, or reinstalla on. All implied warran es for func onality, are valid only un l the warranty expires. This Nortek Security & Control LLC Warranty is in lieu of all other warran es expressed or implied. Nortek Security & Control LLC 2GIG 5. Click Sensor LeŌ Open. Add parameters. Also, click +Add Recipient to add recipients associated with the no fica on. 1950 Camino Vida Roble, Suite 150 Carlsbad, CA 92008-6517 USA For technical support in the USA and Canada: 800.421.1587 Email: 2gigtechsupport@nortek.com Visit www.nortekcontrol.com for technical support hours of opera on For technical support outside of the USA and Canada: Contact your regional distributor 6. Click Close when names have been selected, then click Save NoƟficaƟon. Visit dealer.2gig.com for a list of distributors in your region Copyright © 2017 Nortek Security & Control LLC 10017336 X16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Charles.Sneller Create Date : 2017:07:13 14:32:39-07:00 Modify Date : 2017:07:13 14:37:16-07:00 XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Creator : Charles.Sneller Title : GC-GRILL1-B-345-10017336 X16.indd Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:07:13 14:37:16-07:00 Producer : Acrobat Distiller 17.0 (Windows) Document ID : uuid:14781e06-3109-472c-a63d-2ce5d5c37a57 Instance ID : uuid:c0c07487-3d71-4f5f-a25a-a074d447ca5b Page Count : 2EXIF Metadata provided by EXIF.tools