Novatel Wireless GSM0308 Wireless Modem User Manual Enabler II G Assiste GPS Integration Guide
Novatel Wireless Inc. Wireless Modem Enabler II G Assiste GPS Integration Guide
Contents
- 1. Manual
- 2. User Manual
Manual
GSM0308PB001 Enfora Enabler III-G Integration Guide Version: DRAFT Enfora, Inc. 661 E. 18th Street Plano Texas 75074 www.enfora.com Enfora Enabler III-G Modem Integration Guide Document Title: Enfora Enabler III-G Modem Integration Guide Version: DRAFT Date: 1/31/07 Status: DRAFT Document Control ID: GSM0308PB001 General All efforts have been made to ensure the accuracy of material provided in this document at the time of release. However, the items described in this document are subject to continuous development and improvement. All specifications are subject to change without notice and do not represent a commitment on the part of Enfora, Inc. Enfora, Inc. will not be responsible for any loss or damages incurred related to the use of information contained in this document. This product is not intended for use in life support appliances, devices or systems where a malfunction of the product can reasonably be expected to result in personal injury. Enfora, Inc. customers using, integrating, and/or selling this product for use in such applications do so at their own risk and agree to fully indemnify Enfora, Inc. for any damages resulting from illegal use or resale. Copyright Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording or otherwise), or for any purpose, without the express written permission of Enfora, Inc. Enfora may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from Enfora, the furnishing of this document does not give you any license to these patents, trademarks, copyrights or other intellectual property. ©2002, 2003, 2004, 2005, 2006, 2007 Enfora, Inc. All rights reserved. Enabler and Spider are either registered trademarks or trademarks of Enfora, Inc. in the United States. GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Table of Contents 1. SAFETY PRECAUTIONS .................................................................................................................................1 1.1. 2. REGULATORY COMPLIANCE FCC.............................................................................................................1 2.1. 2.2. 3. IMPORTANT SAFETY INFORMATION ................................................................................................................1 INTEGRATION CONSIDERATIONS AND INSTALLATION REQUIREMENTS ...........................................................1 DISCLAIMER ...................................................................................................................................................3 MANUAL OVERVIEW......................................................................................................................................4 3.1. REVISION HISTORY.........................................................................................................................................4 3.2. REFERENCE DOCUMENTS ...............................................................................................................................5 3.2.1. Enfora Enabler III-G Product Documentation ......................................................................................5 3.2.2. GSM Device Specifications....................................................................................................................6 3.2.3. US Government......................................................................................................................................6 3.2.4. Federal Communications Commission (FCC).......................................................................................6 3.2.5. FCC Office of Engineering and Technology (OET) ..............................................................................6 3.2.6. Industry Canada ....................................................................................................................................7 3.2.7. Environmental Regulations....................................................................................................................7 3.2.8. Mechanical Specifications .....................................................................................................................7 3.2.9. RF and EMI Specifications ....................................................................................................................7 4. INTRODUCTION ...............................................................................................................................................8 4.1. 4.2. 4.3. 4.4. 4.5. 4.6. 4.7. 5. PRODUCT OVERVIEW......................................................................................................................................8 KEY FEATURES OF THE ENABLER III MODULE ...............................................................................................8 PROVIDING MULTI-BAND OPERATION .........................................................................................................10 WIRELESS DATA APPLICATION POSSIBILITIES ..............................................................................................10 GSM/GPRS SYSTEM OVERVIEW .................................................................................................................11 SUMMARY OF FEATURES FOR THE ENABLER III-G MODULE ........................................................................13 GENERAL LAYOUT GUIDELINES FOR ENFORA GSM MODULES .....................................................................15 TECHNICAL SPECIFICATIONS ..................................................................................................................16 5.1. ENABLER III-G MODULE BLOCK DIAGRAM .................................................................................................16 5.2. DETAILED PRODUCT SPECIFICATIONS ..........................................................................................................17 CLIMATIC: STORAGE AND TRANSPORTATION...........................................................................................................17 MECHANICAL: STORAGE AND TRANSPORTATION.....................................................................................................17 MECHANICAL: PROPOSED STANDARDS ....................................................................................................................17 ELECTROMAGNETIC EMISSIONS ...............................................................................................................................17 5.3. OPERATING POWER ......................................................................................................................................18 5.3.1. GSM Operating Power ........................................................................................................................18 5.3.2. GPRS Operating Power.......................................................................................................................18 5.3.3. Typical Input Current ..........................................................................................................................19 5.3.4. GSM Transmit Power ..........................................................................................................................19 5.3.5. GSM Receiver Sensitivity.....................................................................................................................20 6. MECHANICAL .................................................................................................................................................21 6.1. MODULE MOUNTING TO HOST BOARD (REFERENCE)...................................................................................25 6.2. CONNECTORS ...............................................................................................................................................27 6.3. RF CONNECTION OPTIONS ...........................................................................................................................27 6.3.1. Coaxial Connector Option...................................................................................................................27 6.3.2. RF Board-to-Board Connector Option ................................................................................................27 6.3.3. I/O Connector Pin Assignments...........................................................................................................28 6.4. CIRCUIT PROTECTION ...................................................................................................................................30 6.5. ANTENNA .....................................................................................................................................................30 GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6. CONTROL CONNECTOR SIGNAL DESCRIPTIONS AND FUNCTIONS .................................................................31 6.6.1. Module Power (Pins 85, 87, 79, 91, 93, 95, 97, 99) ............................................................................31 6.6.2. Ring Indicate........................................................................................................................................31 6.6.3. Using the Power Control Signal ..........................................................................................................32 6.6.4. Level Translation Reference Power (Pin 77).......................................................................................37 6.6.5. USB (Pins 1, 3, 5, 7, 9) ........................................................................................................................37 6.6.6. LED A (Pin 8) & B (Pin 6), VRWLED (Pin 10)...................................................................................39 6.6.7. LED VRW (Pin 10) ..............................................................................................................................41 6.6.8. General Purpose Input/Output Interface .............................................................................................42 6.6.9. Power Control (Pin 35) .......................................................................................................................43 6.6.10. RTC Sleep ............................................................................................................................................43 6.6.11. Serial Interfaces & Handshake (Pins 11, 13, 15, 17, 19, 21, 23, 25)...................................................43 6.6.12. MCSI – Multi-Channel Serial Interface (Pins 12, 14, 16, 18) .............................................................44 6.6.13. I2C (Pins 48, 50) ..................................................................................................................................45 6.6.14. Serial Port Interface (SPI) (Pins 20, 22, 24, 26, 28, 30)......................................................................46 6.6.15. Keyboard (Pins 27, 29, 31, 32, 33, 34, 36, 38, 40, 42 ) .......................................................................47 6.6.16. VBACKUP Input (Pin 83) .........................................................................................................................48 6.6.17. Using VBAK.........................................................................................................................................49 6.6.18. 32 kHz output (Pin 56).........................................................................................................................49 6.6.19. 13 MHz output (Pin 52) .......................................................................................................................49 6.6.20. Analog-To-Digital Input (Pin 74) ........................................................................................................50 6.6.21. Handset Microphone Input (Pins 65, 67).............................................................................................50 6.6.22. Handset Microphone Bias Output (Pin 63) .........................................................................................50 6.6.23. Handset Speaker Output (Pins 71, 73).................................................................................................51 6.6.24. Headset Microphone Input (Pin 55) ....................................................................................................52 6.6.25. Headset Microphone Bias Output (Pin 53)..........................................................................................52 6.6.26. Headset Speaker Output Left & Right (Pins 57, 59)............................................................................53 6.6.27. Headset Output Common Mode (Pin 61).............................................................................................53 6.6.28. Headset Detect (Pin 47).......................................................................................................................54 6.6.29. Audio Mixer input (Pins 49, 56) ..........................................................................................................55 6.7. SUBSCRIBER IDENTITY MODULE (SIM) CARRIER ........................................................................................56 6.7.1. SIM Integration for the Enfora Enabler III-G Module ........................................................................56 6.7.2. Using a Remote SIM with the Enfora Enabler III-G Module (Pins 76, 78, 80, 82, 84) .......................56 7. GSM/GPRS MODES OF OPERATION .........................................................................................................59 7.1. 7.2. 7.3. 7.4. 8. SIM OPERATION ............................................................................................................................................61 8.1. 8.2. 8.3. 8.4. 9. ENABLING THE TRANSMISSION MODES FOR THE GSM/GPRS SERVICES .....................................................59 VOICE COMMUNICATION ..............................................................................................................................59 CIRCUIT-SWITCHED DATA ...........................................................................................................................59 SMS: SHORT MESSAGE SERVICES ................................................................................................................60 PROVISIONING THE SIM ...............................................................................................................................61 GSM SERVICES SUPPORTED BY THE ENFORA ENABLER III-G MODULE ......................................................61 GPRS SERVICES SUPPORTED BY THE ENFORA ENABLER III-G MODULE .....................................................61 SELECTING THE GSM MODES OF OPERATION ..............................................................................................62 SOFTWARE INTERFACE ..............................................................................................................................63 9.1. SOFTWARE INTERFACE .................................................................................................................................63 9.2. FORMAT FOR THE AT COMMANDS ...............................................................................................................64 9.3. ENFORA AT COMMAND SET ........................................................................................................................65 9.4. ENFORA PACKET APPLICATION PROGRAMMING INTERFACE ........................................................................65 9.4.1. UDP-API Architecture.........................................................................................................................65 9.5. ENFORA MODEM CONTROL LIBRARY ARCHITECTURE .................................................................................67 9.5.1. Using Port Library ..............................................................................................................................68 9.5.2. Using Messaging Library ....................................................................................................................68 GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9.5.3. 10. Using Modem Library..........................................................................................................................70 SETUP AND INITIALIZATION.................................................................................................................70 10.1. GENERAL SETUP .......................................................................................................................................70 10.1.1. HyperTerminal Configuration for Enabler III-G module ....................................................................70 10.1.2. Initialization (AT Command Interface)................................................................................................72 10.1.3. Initial Response to the AT Command...................................................................................................73 10.1.4. Sending an Initialization String to the Enfora Enabler III-G Module .................................................73 10.1.5. Setting Up the Communication Mode for the Enfora Enabler III-G Module.......................................74 10.1.6. Querying the Status of the Enfora Enabler III-G Module....................................................................75 10.1.7. Setting Module Reporting Parameters for GSM and GPRS ................................................................75 10.2. GSM/SMS EXAMPLES .............................................................................................................................75 10.2.1. Initialize the Enfora Enabler III-G Module to Send and Receive SMS Text Messages........................75 10.2.2. Managing SMS Messages ....................................................................................................................75 10.2.3. Data Call Configuration......................................................................................................................75 10.2.4. Voice Call Configuration.....................................................................................................................75 10.3. GPRS PACKET EXAMPLES .......................................................................................................................75 10.3.1. GPRS ATTACH and ACTIVATE..........................................................................................................75 10.3.2. Windows PPP Setup.............................................................................................................................75 11. INTEGRATION AND TESTING ................................................................................................................76 11.1. 12. INTEGRATING THE ENFORA ENABLER III-G MODULE ..............................................................................76 APPENDIX A................................................................................................................................................79 LIMITED WARRANTY...........................................................................................................................................79 12.1. SCOPE .......................................................................................................................................................79 12.1.1. Hardware.............................................................................................................................................79 12.2. SOFTWARE................................................................................................................................................79 12.3. OTHER CONSIDERATIONS .........................................................................................................................80 13. APPENDIX B - REGULATIONS AND COMPLIANCE ..........................................................................82 13.1. GCF/PTCRB APPROVAL (FORMERLY FTA) ............................................................................................82 13.2. ELECTROMAGNETIC COMPATIBILITY (EMC) AND SAFETY REQUIREMENTS.............................................82 13.3. EMC/SAFETY REQUIREMENTS FOR THE USA ..........................................................................................82 13.4. HUMAN EXPOSURE COMPLIANCE STATEMENT .........................................................................................83 13.5. COMPLIANCE WITH FCC REGULATIONS ...................................................................................................83 13.6. UNINTENTIONAL RADIATORS, PART 15....................................................................................................84 13.7. INTENTIONAL RADIATORS, PART 22 & 24................................................................................................84 13.8. INSTRUCTIONS TO THE ORIGINAL EQUIPMENT MANUFACTURER (OEM)..................................................85 13.8.1. OEM Responsibilities for All Products Containing the Enabler III-G module....................................87 13.8.2. Specific OEM Responsibilities for Portable Products and Applications .............................................88 13.8.3. Specific OEM Responsibilities for Mobile Products and Applications................................................88 13.8.4. Specific OEM Responsibilities for Fixed Products and Applications..................................................88 13.9. EMC/SAFETY REQUIREMENTS FOR THE COUNTRIES OF THE EUROPEAN UNION (EU)..............................89 13.10. EMC/SAFETY REQUIREMENTS FOR OTHER COUNTRIES ...........................................................................89 14. APPENDIX C - GLOSSARY AND ACRONYMS......................................................................................90 15. APPENDIX D – TABLES AND FIGURES.................................................................................................92 16. APPENDIX E - CONTACTING ENFORA.................................................................................................93 GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 1. Safety Precautions 1.1. Important Safety Information The following information applies to the devices described in this manual. Always observe all standard and accepted safety precautions and guidelines when handling any electrical device. • Save this manual: it contains important safety information and operating instructions. • Do not expose the Enfora Enabler III-G product to open flames. • Ensure that liquids do not spill onto the devices. • Do not attempt to disassemble the product: Doing so will void the warranty. With the exception of the Subscriber Identification Module (SIM), this product does not contain consumer-serviceable components. 2. Regulatory Compliance FCC 2.1. Integration Considerations and Installation Requirements The Enabler III-G modem is designed for use in a variety of host units, "enabling" the host platform to perform wireless data communications. However, there are certain criteria relative to integrating the modem into a host platform such as a PC, laptop, handheld or PocketPC®, monitor and control unit, etc. that must be considered to ensure continued compliance with FCC compliance requirements. • In order to use the Enabler III-G modem without additional FCC certification approvals, the installation must meet the following conditions: • Maximum RF output power and antenna gain to meet Maximum Permissible Exposure Requirements: GSM850 mode: Power at antenna port is +32 dBm. The maximum gain is 4.5 dBi(2.35 dBd). GSM1900 mode: Power at antenna port is 31.3 dBm. The maximum gain is 2 dBi in order to meet the requirements of maximum 2 watts EIRP for mobile transmitters.If RF power and/or antenna gain is desired, a separate FCC certification is required. • If used in a "portable" application such as a handheld or body worn device with the antenna less than 20 cm (7.9 in.) from the human body when the device is operating, then the integrator is responsible for passing additional "as installed" testing and the device will require it’s own FCC ID: • SAR (Specific Absorption Rate) testing, with results submitted to the FCC for approval prior to selling the integrated unit. If unable to meet SAR requirements, then the host unit must be restricted to "mobile" use (see below). • Unintentional emissions, FCC Part 15; results do not have to be submitted to the FCC unless requested, although the test provides substantiation for required labeling (see below). • ERP and EIRP measurements for FCC Parts 22 and 24, alternatively a full retest on FCC Parts 22 and 24 can be performed GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide • If used in a "mobile" application where the antenna is normally separated at least 20 cm (7.9 in) from the human body during device operation, then an appropriate warning label must be placed on the host unit adjacent to the antenna. The label should contain a statement such as the following: WARNING RF exposure. Keep at least 20 cm (7.9 in) separation distance from the antenna and the human body. • Host unit user manuals and other documentation must also include appropriate caution and warning statements and information. • If the FCCID for the modem is not visible when installed in the host platform, then a permanently attached or marked label must be displayed on the host unit referring to the enclosed modem. For example, the label should contain wording such as: Contains GSM/GPRS modem transmitter module FCC ID: MIVGSM0308 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. OR Contains FCC ID: MIVGSM0308 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. • Any antenna used with the modem must be approved by the FCC or as a Class II Permissive Change (including MPEL or SAR data as applicable). The "professional installation" provision of FCC Part 15.203 does not apply. GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide • The transmitter and antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Violation of this would allow a user to plug another transmitter in to the product and potentially create an RF exposure condition. WARNING The transmitter and antenna must not be collocated or operating in conjunction with any other antenna or transmitter. Failure to observe this warning could produce an RF exposure condition. 2.2. Disclaimer The information and instructions contained within this publication comply with all FCC, GCF, PTCRB, R&TTE, IMEI and other applicable codes that are in effect at the time of publication. Enfora disclaims all responsibility for any act or omissions, or for breach of law, code or regulation, including local or state codes, performed by a third party. Enfora strongly recommends that all installations, hookups, transmissions, etc., be performed by persons who are experienced in the fields of radio frequency technologies. Enfora acknowledges that the installation, setup and transmission guidelines contained within this publication are guidelines, and that each installation may have variables outside of the guidelines contained herein. Said variables must be taken into consideration when installing or using the product, and Enfora shall not be responsible for installations or transmissions that fall outside of the parameters set forth in this publication. Enfora shall not be liable for consequential or incidental damages, injury to any person or property, anticipated or lost profits, loss of time, or other losses incurred by Customer or any third party in connection with the installation of the Products or Customer's failure to comply with the information and instructions contained herein. The Enabler III-G platform is designed with features to support a robust connection. There are instances where the module performance is beyond the control of the intended design. Integrated designs that require 24 by 7 operation must implement power control via an external circuit or by implementing power management as specified within this design guide. GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 3. Manual Overview This document describes the hardware interface of the Enabler III-G modem. The purpose of this document is to define the electrical, mechanical and software interfaces while providing detailed technical information in order to streamline the process of hardware and system integration. 3.1. Revision History Date 01/17/07 Rev 1.00 GSM0308PB001 Author Tom Cone Description Initial Release Draft Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 3.2. Reference Documents 3.2.1. Enfora Enabler III-G Product Documentation Overview • GSM1000PB001MAN - Enfora Integrated GSM/GPRS Module Manuals • GSM0308PB001MAN - Enfora GSM/GPRS OEM Module AT Command Set Reference • GSM0102PB002MAN - Enfora GSM-GPRS Family UDP-API Reference • GSM0000PB006MAN - Enfora GSM-GPRS Family Modem Control Library Reference Application Notes • GSM0000AN001 - Enabler-G PPP Configuration for Windows 98 • GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000 • GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use • GSM0000AN004 - Enabler-G SMS Configuration and Use • GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use • GSM0000AN006 - Enabler-G Module Status Query • GSM0000AN007 - Enabler-G Status Reporting • GSM0000AN008 - Enabler-G PPP Configuration for Windows XP • GSM0000AN009 - Dynamic IP Assignment Support • GSM0000AN010 - Enabler-G PPP Configuration for PocketPC 2002 • GSM0000AN011 - PAD Configuration and Use • GSM0000AN012 - Network Transparency Configuration for PAD • GSM0000AN013 - Enabler-G Sleep Mode Configuration and Use • GSM0000AN014 - Anytime PPP API Access • GSM0000AN015 - Event Monitor and Reporting Overview • GSM0000AN016 - How to Send SMS Messages to an E-Mail Address • GSM0000AN017 - SMTP Mail Access via TCP PAD • GSM0000AN018 - USNO NTP Network Time Service TCP PAD GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Technical Notes • GSM0000TN001 - Enabler-G Firmware Upgrade • GSM0000TN002 - Enabler-G PPP Negotiation Sequence • GSM0000TN006 - UDP Wakeup Message Header Decoding • GSM0000TN007 - Enabler-G 3-Wire Serial Interface Requirements • GSM0000TN008 - Enabler Power Supply Requirements • GSM0000TN009 - Server Application Design Considerations for Dynamic IP • GSM0000TN012 – Enabler III-G Engineering Mode Command Reference • GSM0000TN013 – Enabler III-G and IIE CMUX Description White Papers • GSM0000WP001 - Enabler-G Differentiation Features • GSM0000WP002 - Using Enfora UDP API Versus CMUX Protocol 3.2.2. GSM Device Specifications • 3GPP TS 51010-1 (850, 900,1800,1900 MHz devices) To view the latest release, go to: http://www.3gpp.org/ftp/Specs/html-info/51010-1.htm 3.2.3. US Government 3.2.4. Federal Communications Commission (FCC) Internet: http://www.fcc.gov/ • FCC Rules, Part 24 • • 47 CFR Subpart E--Broadband PCS 47 CFR § 24.52, sections 1.1307(b), 2.1091, and 2.1093 • FCC Rules, Part 22 for GSM 850 • FCC Rules, Part 15 • FCC Rules, Part 2 • • 3.2.5. Subpart J--Equipment Authorization Procedures Section 2.925 FCC Office of Engineering and Technology (OET) Internet: http://www.fcc.gov.oet/ • Bulletin Number 65 "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields" • Supplement C "Additional Information for Evaluating Compliance of Mobile and Portable Devices with FCC Limits for Exposure to Radio Frequency Emissions" GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 3.2.6. 3.2.7. Industry Canada • RSS-132 • RSS-133 • ICES-003 Environmental Regulations • 3.2.8. National Environmental Policy Act (NEPA) of 1969 (Part 1, Subpart 1) Mechanical Specifications • • • • • • • 3.2.9. ASTM D999 ASTM D775 IEC 68-2-27 Bellcore Gr-63-CORE ETS 300 019-1-1 Class 1.2 ETS 300 019-1-2 Class 2.1 ETS 300 019-1-3 Class 3.1 RF and EMI Specifications • • • • • ETSI Standards EN 61000-4-6 EN 61000-4-3 3GPP TS 51.010-1, Section 12.2 EN 55022 Class B GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 4. Introduction 4.1. Product Overview Enfora Enabler III-G modem is a compact, wireless OEM module that utilizes the Global System for Mobile Communications (GSM) and GPRS (General Packet Radio Services) international communications standard to provide two-way wireless capabilities via GSM services. The Enfora Enabler III-G module is a fully Type-approved GSM/GPRS device, enabling application-specific, two-way communication and control. The small size of the Enfora Enabler III-G module allows it to be integrated easily into the application and packaging. 4.2. Key Features of the Enabler III Module The following table summarizes the main features of the Enfora Enabler III-G Radio Module. Interface Data input/output interface Primary serial port 100 position 0.4mm pitch connector V.24 protocol, 1.8V levels, full 9-pin, UART implementation V.24 protocol, 1.8V levels (debug only) 20 pins available (feature specific on some lines) USB full-speed (FS) device compatible with the Universal Serial Bus Specification Revision 2.0 and the universal Serial Bus Specification Revision 1.1. Multi- Master Serial Computer Bus Serial Peripheral Interface 5 x 5 keyboard support Digital audio via MCSI port Supports four vocoder modes: full-rate (FR), enhanced full-rate (EFR), half-rate (HR), and adaptive multi-rate (AMR) ultra Miniature Coaxial Interconnect or B2B Spring contact Enfora Packet API, GSM AT command set Optional 1.8/3 V mini-SIM carrier and interface on board with SIM detect Voltage backup pin available to maintain RTC, battery capable 32kHz and 13 Mhz. output reference clocks 1 ADC port Accessible via the 100-pin connector 3.3 to 4.5 Vdc Refer to the Operating Power table in the Technical Specifications for peak currents and average power dissipation for various modes of operation. EGSM 900, GSM1800, GSM 850 and GSM 1900 capability. Provides for all GSM/GPRS authentication, encryption, and frequency hopping algorithms. GPRS Coding Schemes CS1-CS4 supported. Multi-Slot Class 10 (4RX/2TX, Max 5 Slots). Secondary serial port GPIO USB I2C SPI Port Keyboard Audio Voice Antenna Interface Command protocol Subscriber Identification Module (SIM) Voltage backup Power Radio Features Reference clock ADC Optional remote SIM Electrical power Peak currents and average power dissipation Frequency bands GSM/GPRS features supported GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Regulatory • Headset Microphone biasing • Headset Plug/Unplug detection • Headset Hook detection (call answer/end button on equipped Headset microphone device) • High output dynamic differential Earphone mode, using Headset outputs • Pop Noise attenuation circuitry implemented for all single-ended output stages • Mono Voice memo capability: Voice memo function is supported for both 8 kHz Narrowband and 16 kHz • FM stereo audio mux input (FML pin, FMR/AUXI pin) • FM mono audio mux input (FMR/AUXI pin only) • Handset microphone input (MICIN, MICIP pins) • Headset microphone input (HSMIC pin) • • Car kit microphone (D+ pin) Handset earphone outputs (EARP, EARN pins) • Headset 32 Ω stereo outputs (HSOL, HSOR pins) • USB car kit stereo outputs (D+(right), D- (left) pins) • USB car kit mono output (D- (left) pin) • GSM/GPRS Functionality Audio Features Outputs SIM • • • • • • • • • GCF Type Approval • PTCRB Type Approval • FCC Certification • RTTE • CE (European Community Certification) • IC (Industry Canada) Approval Mobile-originated and mobile-terminated SMS messages: up to 140 bytes or up to 160 GSM 7-bit ASCII characters. Reception of Cell Broadcast Message SMS Receipt acknowledgement Circuit Switched Data (Transparent & Non-transparent up to 9.6 Kbps) Voice (EFR, FR, HR) Supports Unstructured Supplementary Service Data (USSD) Multi-Slot Class 10 Supported (4Rx/2TX), (5 Slot Max) PBCCH/PCCCH Supported Handset Microphone biasing Agency approvals 1.8/3 V Mini-Subscriber Identity Module (SIM) compatible Table 1 - Enabler III-G Key Features GSM0308PB001 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 4.3. Providing Multi-Band Operation The Enfora Enabler III-G module provides multi-band operation, with the operating frequency selectable by AT Command: 4.4. • The 850/1900 MHz radio bands are available for integration and deployment for use worldwide, with 850/1900 MHz support primarily in North America and regions where the 1900 MHz Personal Communication Services (PCS) band is allocated. The Enfora Enabler III-G also supports GSM 850 for use in North America. • The 900/1800 MHz Enfora Enabler III-G modules are available for deployment in Europe and the rest of the world. Wireless Data Application Possibilities A variety of applications can use the Enfora Enabler III-G module for transmitting/receiving data/voice, such as: • Automated Meter Reading (AMR) • Point of Sale Applications • E-mail and Internet access • Automated Vehicle Location (AVL) • Machine to Machine communication (M2M) • Telematics • Telemetry • Wireless Security GSM0308PB001 10 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 1 – UDP API Architecture 4.5. GSM/GPRS System Overview The Enfora Enabler III-G module is shown in Figure 1 is designed for easy integration with other components and packaging by leveraging the existing GSM networks. Compare the Enfora Enabler III-G to systems that require construction, operation, maintenance, and expense of a private network. GSM0308PB001 11 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 2 - PAD Architecture GSM0308PB001 12 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 4.6. Summary of Features for the Enabler III-G Module The following summarizes the main features of the Enfora Enabler III-G Module. Mechanical Dimensions................................... 27.0 mm x 28.0 mm x 2.50 mm Weight .......................................... 3.6g Packet Data Transfer: Protocol……………………………………………GPRS Release 97 and 99 Coding Schemes…………………………………CS1-CS4 Multi-Slot Capability: (Demonstrated @MS10)…….MS10 (4RX/2TX) (Max 5 Slots) Packet Channel Support .............. ……………..PBCCH/PCCCH Circuit Switched Data Transfer: V110 ............................................. 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps Non-Transparent .......................... 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps Short Message Services: GSM SMS .................................... MO, MT, CB, Text and PDU Modes GPRS SMS .................................. MO, MT, CB, Text and PDU Modes Voice Capability: Speech Codec.............................. EFR, FR, HR, AMR GSM/GPRS Radio Performance Multi-Band: GSM0308 Radio Frequencies...... 850 MHz, 900 MHz, 1800 MHz, and 1900 MHz Sensitivity ..................................... <-106 dBm (Typical GPRS CS1) 850 & 900 MHz Transmit Power .. Class 4 (2 W) 1800 & 1900 MHz Transmit Power ......................... Class 1 (1 W) System Requirements: Host Interface ............................... Serial Interface DC Voltage ................................... 3.3 to 4.5 Vdc GSM0308PB001 13 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Application Interface: Host Protocol................................ Status API and AT Commands Internal Protocols ......................... UDP stack, TCP/IP stack, PPP, PAD, and CMUX Physical Interface......................... 1 serial (primary), I USB (debug) Default rate 115,200 baud, MCSI, I2C, SPI, Keyboard (5x5) Audio Interface.............................. FM stereo audio mux input (FML pin, FMR/AUXI pin), FM mono (FMR/AUXI pin only), Handset microphone input (MICIN, MICIP pins), Headset microphone input (HSMIC pin), Car kit microphone (D+ pin), Handset earphone outputs (EARP, EARN pins), Headset 32 Ω stereo outputs (HSOL, HSOR pins), USB car kit stereo outputs (D+, D- pins), USB car kit mono output (D- pin) SIM Interface: Remote SIM Option 1.8/3-Volt SIM Capability Environmental: Compliant Temperature .............. -20 °C to 60 °C (Fully GSM Spec Compliant) Operating Temperature ………….-30 °C to 70 °C Storage Temperature ................... -40 °C to 85 °C Humidity ....................................... 5 to 95% non-condensing EMC: Emissions ..................................... FCC Parts 15,22 & 24, Class B 3GPP TS 51010-1, Section 12.2 EN 55022 Class B Operating Power (TYPICAL): GSM Operation GSM 850/900 (1 RX/1 TX, full power)………..TBD mA average, 1.6 A peak GSM 1800 (1 RX/1 TX, full power)……………TBD mA average, 1.3 A peak GSM 1900 (1 RX/1 TX, full power)……………TBD mA average, 1.2 A peak Idle................................................ ………….. TBD mA Shutdown ..................................... ……………≈ TBD uA GPRS Operation Power EGSM 850/900 (4 RX/1 TX, full power)…………… TBD mA average, 1.6 A peak EGSM 850/900 (2 RX/2 TX, full power)…………... TBD mA average, 1.6 A peak GSM 1800 (4 RX/1 TX, full power)………………… TBD mA average, A peak GSM 1800 (2 RX/2 TX, full power) TBD mA average, A peak GSM 1900 (4 RX/1 TX, full power)………………... TBD mA average, A peak GSM 1900 (2 RX/2 TX, full power)………………… TBD mA average, A peak Idle................................................ …………...…… TBD Shutdown ..................................... …………….….≈ TBD uA GSM0308PB001 14 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide GSM Transmit Power 1800/1900 MHz............................ GSM Power Class 1 (30 dBm ± 2 dB @ antenna connection) 850/900 MHz ................................ GSM Power Class 4 (33 dBm ± 2 dB @ antenna connection) GSM/GPRS Receiver Sensitivity (Typical) 1800/1900 MHz............................ <-106 dBm, GPRS Coding Scheme 1 (CS1) 850/900 MHz ................................ <-106 dBm, GPRS Coding Scheme 1 (CS1) 4.7. General layout guidelines for Enfora GSM modules To ensure lowest possible EMI emission, maximum thermal conduction and mechanical integrity, all metal tabs on the GSM module shield must be soldered down on to a continuous ground plane. The PCB trace that feeds the RF output port must be 50ohm characteristic impedance, coplanar, or routed into internal layers to keep the top layer continuous around and underneath the device. Provide ample ground vias around metal tabs, the RF trace and launch pad. If possible, keep I/O and power traces away from the RF port. GSM0308PB001 15 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 5. Technical Specifications 5.1. Enabler III-G Module Block Diagram Figure 3 - Enabler III-G Module Block Diagram GSM0308PB001 16 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 5.2. Detailed Product Specifications Physical Dimensions and Weight Size (L x W x H) 27.0 mm x 28.0 mm x 2.50 mm Weight (3.6 g) Climatic: Operational GSM Compliant temperature Operating temperature -20°C to +60°C -30°C to +70°C Relative humidity 5 - 95% Solar radiation Air pressure (altitude) Not Applicable 70 kPa to 106 kPa (-400 m to 3000 m) Climatic: Storage and Transportation Duration Ambient temperature Relative humidity Thermal shock Altitude 24 months -40C to +85C 5% to 95%, non condensing (at 40C) -50C to +23C, +70C to +23C; < 5 min -400 m to 15,000 m Mechanical: Operational Operational vibration, sinusoidal 3.0 mm disp, 2 to 9 Hz; 1 m/s2 , 9 to 350 Hz Operational vibration, random 0.1 m2 /s3 , 2 to 200 Hz Mechanical: Storage and Transportation Transportation vibration, packaged Drop, packaged Shock, un-packaged Drop, un-packaged ASTM D999 ASTM D775 method A, 10 drops 150 m/s2 , 11 ms, half-sine per IEC 68-2-27 4-inch drop per Bellcore GR-63-CORE Mechanical: Proposed Standards Transportation Operational Storage ETSI Standard ETS 300 019-1-2 Class 2.3 Transportation ETSI Standard ETS 300 019-1-3 Class 3.1 Operational ETSI Standard ETS 300 019-1-1 Class 1.2 Storage Electromagnetic Emissions Radiated spurious FCC Part 22 & 24 / Part 15 Class \ B 3GPP TS 51.010-1 Section 12.2 EN 55022 Class B GSM0308PB001 17 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 5.3. Operating Power The Enfora Enabler III-G module requires an input voltage of 3.3 Vdc to 4.5 Vdc. 5.3.1. GSM Operating Power Enfora Enabler III-G (@ 3.76 Volts) Typical Current (mAmps) Typical Peak Current (Amps) GSM 850 EGSM 900 GSM 1 TX 1 RX 1 RX Idle 254 mA 104 mA TBD mA 1.6 A @ 32.5 dBm GSM 1800 GSM 1 TX 1 RX 1 RX Idle 212 mA 104 mA TBD mA Error! Reference source not found. A @ 29.5 dBm GSM 1900 GSM 1 TX 1 RX 1 RX Idle 200 mA 104 mA TBD mA Error! Reference source not found. A @ 29.5 dBm 5.3.2. GPRS Operating Power Enfora Enabler III-G (@ 3.76 Volts) Typical Current (mAmps) Typical Peak Current (Amps) GSM 850 EGSM 900 GPRS 1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA 1.6 A @ 32.5 dBm GSM 1800 GPRS 1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA Error! Reference source not found. A @ 29.5 dBm GPRS 1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA TBD mA Error! Reference source not found. A @ 29.5 dBm GSM0308PB001 18 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 5.3.3. Typical Input Current Test Conditions: Typical Results @ 3.7 V with 2000 μF at connector input on VBAT terminated into a 50 Ω resistive load. GSM Operation Band Mode 1900 1800 1 RX/1 TX, Full Power 900 850 ALL Idle N/A Shutdown GPRS Operation Band Mode 4 RX/1TX, Full Power 1900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 1800 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 900 2 RX/2TX, Full Power 1 RX/1TX, Full Power 4 RX/1TX, Full Power 850 2 RX/2TX, Full Power 1 RX/1TX, Full Power ALL Idle N/A Shutdown 5.3.4. Low Input Current Nom/Avg High/Peak Units mA mA mA mA Low Input Current Nom/Avg High/Peak Units mA mA mA mA mA mA mA mA mA mA mA mA GSM Transmit Power Enfora Enabler III-G module Power Class Transmit Power 1900 MHz 1800 MHz GSM Power Class 1 1-W conducted power maximum (30 dBm +/- 2 dB), measured at the antenna port 850 MHz 900 MHz GSM Power Class 4 2-W conducted power maximum (33 dBm +/- 2 dB), measured at the antenna port GSM0308PB001 19 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 5.3.5. GSM Receiver Sensitivity Enfora Enabler III-G module 1900 MHz 1800 MHz 900 MHz 850 MHz GSM0308PB001 Sensitivity -106 dBm (typical) -106 dBm (typical) 20 Mode GPRS Coding Scheme 1 (CS1) GPRS Coding Scheme 1 (CS1) Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6. Mechanical (Dimensions are in millimeters.) Figure 4 – Front of Module (Board-to-Board RF Conn. Version) GSM0308PB001 21 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 5 - Pin 1 Reference, 100-Pin I/O Connector GSM0308PB001 22 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 6 – Front of Module (Coaxial RF Conn. Version) GSM0308PB001 23 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 7 - Back of Module (Option SIM Shown) GSM0308PB001 24 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.1. Module Mounting to Host Board (Reference) The module provides mounting tabs that must be soldered to a PCB. These tabs provide circuit grounding for the module. Figure 8 – Module Mounting GSM0308PB001 25 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 9 - Host Pads for Board-To-Board RF Connector GSM0308PB001 26 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.2. Connectors On The Modem: 100-Pin I/O Connector, Plug, SMT, Dual Row, 0.4 mm Pitch Enfora PN = CON-1040-0100 Molex PN = 55909-1074 On The Host: 100-Pin I/O Connector, Socket, SMT, Dual Row, 0.4 mm Pitch Enfora PN = CON-1040-0101 Molex PN = 51338-1074 The mated height of the two connectors is 1.50 mm. 6.3. RF Connection Options 6.3.1. Coaxial Connector Option On The Modem: Sunridge MCD Series – Ultimate Miniature Coaxial Interconnect, 1.55mm Mated Height Contact Sunridge for mating cable options: Enfora PN = CON-0009-0005 Sunridge PN = MCD-ST-00T http://sunridgecorp.com/ Sunridge Corporation 2500 E. Foothill Blvd. Suite 107 Pasadena, CA 91107 U. S. A. Tel: (626) 535-1780 Fax: (626) 535-1788 6.3.2. RF Board-to-Board Connector Option On The Modem: Enfora PN = CON-0009-0006 Sunridge PN = MCE-15A-G01 On The Host PCB: No connector required. See Figure 9 for layout details. GSM0308PB001 27 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.3.3. I/O Connector Pin Assignments The following table shows the pin assignments for the input/output connector. Table 2 - Enabler III-G Pin Assignments PIN FUNCTION Serial Pin I/O ENABLER III-G Description/Comments (Default function / secondary function) Power Input (USB) VBUS USB power Ground GND System Ground Power Input (USB) VBUS USB power Ground GND System Ground I/O USB_DP/RXD/MIC_R 5 V tolerant data plus pin in USB modes / Receive function in UART mode / Microphone or right speaker in AUDIO mode LED B sink LED_B I/O USB_DM/TXD/SPKR_L 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 I/O I/O I/O I/O I/O LED_A ID_USB VRWLED UART_CTS MCSI_RX/GPIO12 UART_RTS MCSI_CLK/GPIO9 UART_TX MCSI_FSYNC/GPIO10 DSR_RXIR MCSI_TX / GPIO11 DCD_TXIR SPI_\CS2 / GPIO18 UART_RX SPI_MOSI / GPIO15 UART_RING SPI_\CS0/GPIO16 UART_DTR SPI_MISO/GPIO14 KBC0/GPO25 SPI_\CS1/GPIO17 KBC2/GPO27 SPI_CLK/GPIO13 KBC3/GPO28 KBC4/GPIO20 KBC1/GPO26 KBR4/GPIO19 PWR_CTL KBR3/GPI24 RESERVED KBR0/GPI21 5 V tolerant data minus pin in USB modes / Transmit function in UART mode / Monaural speaker or left speaker in AUDIO mode LED A sink USB connector identification Output voltage for VRWLED regulator UART Clear to send[MG1] GPIO12 / MCSI Serial data input UART Request to send GPIO9 / MCSI Serial Clock I/O UART Serial data output GPIO10 / MCSI Frame Synchronization I/O UART Data set ready/ IrDA Serial data input GPIO11 / MCSI Serial Data Output UART Data carrier detect/IrDA Serial data output GPIO18 / SPI Chip select 2 UART Serial data input GPIO15 / SPI Data master out/slave in UART/Modem ring indicate GPIO16 / SPI Chip select 0 UART Data Terminal Ready GPIO14 / SPI Data master in/slave out Keyboard Matrix Column 0 / GPIO25 GPIO17 / SPI Chip select 1 Keyboard Matrix Column 2 / GPIO27 GPIO13 / SPI serial clock Keyboard Matrix Column 3 / GPIO28 Keyboard Matrix Column 4 / GPIO20 Keyboard Matrix Column 1 / GPIO26 Keyboard Matrix Row 4 / GPIO19 External switch-on event (ON Button) with 32-kHz debouncing Keyboard Matrix Row 3 / GPI24 RESERVED Keyboard Matrix Row 0 / GPI21 KBR1/GPI22 Keyboard Matrix Row 1 / GPI22 KBR2/GPI23 Keyboard Matrix Row 2 / GPI23 HST_DET I2C_2_SCL FML 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Clear To Send Request To Send Serial Data Transmit Data Set Ready Data Carrier Detect Serial Data Receive Ring Indicate Data Terminal Ready (OPEN) (OPEN) (OPEN) (OPEN) (OPEN) (OPEN) GSM0308PB001 28 Headset Detect I C interface Master serial clock Mixer/FM radio input left channel Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 50 51 I/O 52 53 54 55 56 57 58 I/O 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Ground I/O I/O I/O I/O I/O I/O I/O PWR PWR Ground Ground I2C_2_SDA AUXI_FMR CLK13M_BUF HSMICBIAS GND HSMIC CLK32K_BUF HSOL GPIO_4/TX_ACT/ LEDPULSE HSOR GPIO_3/LPWM HSOVMID USB_BOOT/GPIO_2 MICBIAS GPIO_1/PWTONE MICIP GPIO_7/SPIRW MICIN GPIO_5/SPICS0 GND GPIO_6/SPIEN EARP GPIO_8/SPIDAT EARN ADCIN4 GND VRSIM VRIO SIM_CLK I C interface Serial bi-directional data Mixer/FM radio input right channel / SE auxiliary amplifier input 13 MHz Clock Output via 1 kΩ Series Resistor Headset microphone bias System ground Microphone input (Headset) 32.768 kHz out, only buffered by 10 kΩ resistor 32 kΩ headset amplifier Left GPIO 4/Transmit Active/LED Pulse 32 kΩ headset amplifier Right GPIO 3 / Light Output PWM Headset output common mode GPIO 2 Microphone bias GPIO 1 / Pulse Width Tone Microphone amplifier positive input (Handset) GPIO 7 / SPI Read Write Microphone amplifier negative input (Handset) GPIO 5 / SPICS0 System Ground GPIO 6 / SPI Enable 33 Ω or 120 Ω speaker amplifier (+) (Analog) GPIO 8 / SPI Data 33 Ω or 120 Ω speaker amplifier (-) (Analog) 10-bit A-to-D System Ground Output voltage for SIM 1.8 V /2.85 V 1.8 V out – Reference for external level translation SIM Card Reference Clock (OPEN) SIM_RST I/O SIM_IO VBACKUP SIMDTC VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND VBAT GND SIM card reset (OPEN) Ground Ground Ground Ground Ground Ground Ground Ground SIM card I/O data Backup battery voltage SIM card insertion/extraction detect with 32-kHz debouncing Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground Power from Host System Ground I=Input into Enabler; O=Output from Enabler; P=Power Input to Enabler; R=Power Return from Enabler; I/O=Input/Output into/from Enabler, PWR=Other Power Reserved for future use NO CONNECT if on-board SIM holder is used Open Lines GSM0308PB001 29 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.4. Circuit Protection Other than very low level ESD protection within the module’s integrated circuits, the module does not have any protection against ESD events or other excursions that exceed the specified operating parameters. Generally, ESD protection (typically TVS/Transzorb devices) should be added to all signals that leave the host board. This includes VBAT/VCC. Series resistors (typically 47 Ω) can also be added in series with data lines to limit the peak current during a voltage excursion. Minimum ESD Protection Levels Pin #’s ESD Test Method Pins 11 – 24, 26-34, 36, 38, 40, 42, 48, 50, 52, 58, 60, 62, 64, 66,68, 70, 72, 78, 80, 82 Pins (all VBUS/PWR), 5 – 10, 35, 37, 47, 49, 51, 52, 53, 55 – 57, 59, 61, 63, 65, 67 Min ESD/Input Voltage Nom/ High/ Avg Peak Units Human Body Model EIA/JEDEC22-A114-A Charge Device Model EIA/JEDEC22-C101-A 500 200 Human Body Model EIA/JEDEC22-A114-A Charge Device Model EIA/JEDEC22-C101-A 2000 500 Caution – It is the Integrator’s responsibility to protect the Enabler III-G module from electrical disturbances and excursions, which exceed the specified operating parameters. 6.5. Antenna The GSM0308-xx module has one RF antenna connection on the module. The connection is for the GSM section of the module. GSM0308PB001 30 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6. Control Connector Signal Descriptions and Functions Please note that the following descriptions are intended to provide hardware-level definitions. In some cases, specific lines will have no firmware functionality implemented. Information for each hardware-specific feature will be noted in the appropriate section. 6.6.1. Module Power (Pins 85, 87, 79, 91, 93, 95, 97, 99) The Enfora Enabler III-G module uses a single voltage source of VCC=+3.3V to 4.5V. (The exact values of the uplink currents are shown in Tables5.3.1 GSM Operating Power and 5.3.2 GPRS Operating Power). VBAT Main Battery Supply Parameter/Conditions Voltage In Regulation Min 3.3 Peak Current 1000 μF on Host at Module Connector Typ Max 4.5 Units Vdc mA The uplink burst will cause strong ripple on the voltage lines and should be effectively filtered. It is recommended that 1000 to 2000 μF of capacitance be placed as close to the modem I/O connector as possible. It should be noted that the input voltage level should not drop below the minimum voltage rating under any circumstances, especially during the uplink burst period. 6.6.2. Ring Indicate The Enabler III-G module is capable of using the Ring line to discern the type of incoming call. The indicator can be monitored via a hardware line available on the 100-pin I/O signal connector. The Ring Indicator pin is #49. The function of the Ring line depends on the type of the call received. When the module is receiving a voice call, the Ring line goes low for 1 second and high for another 2 seconds. Every 3 seconds the ring string is generated and sent over the Receive (Data Out) (Rx) line. If there is a call in progress and call waiting is activated for a connected handset or hands free device, the Ring pin switches to ground in order to generate acoustic signals that indicate the waiting call. GSM0308PB001 31 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Ring 2 seconds 1 second 2 seconds 1 second RING String RING String When a Fax or data call is received, Ring goes low and will remain low. Every 3 seconds a ring string is generated and sent over the Receive (Data Out) (Rx) line. Ring 3 seconds 3 seconds RING String RING String RING String An incoming SMS can be indicated by an Unsolicited Result Code (URC) which causes the Ring line to go low for 1 second only. Using the AT+CNMI command, the Enabler III-G module can be configured to send or not to send URCs upon the receipt of SMS. See Enfora Enabler-III AT Command Set - GSM0308PB001MAN. Ring 1 second URC Figure 10 - Ring Indicate Timing 6.6.3. Using the Power Control Signal Figure 11 shows a typical connection to the Enfora Enabler III-G module in a machine-to-machine application using the external PWR_CTL_SIGNAL solution, where there is no external processor controlling the I/O, serial, or power on/off states. RTC deep sleep functions will NOT function since the PWR_CTL_SIGNAL pin is tied low, the processor will never stay in a “RTC Sleep” mode. To reset the module, power (BATT) must be cycled. VBAK must be connected to an uninterruptible power source if RTC time is to be retained. Note: RESET functionality is not supported on the Enabler III GSM0308PB001 32 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 11 - External Power Control Signal (no external processor) GSM0308PB001 33 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 12 shows a variation of the connection in Figure 11 - External Power Control Signal (no external processor) by using an external RC circuit to generate a pulse that will allow the processor to enter the RTC deep sleep modes. This will keep the PWR_CTL_SIGNAL signal low for at least 500ms during startup. To reset the module, power (BATT) must be cycled, and power must be removed long enough for the RC to discharge. Figure 12 - External Power Control Signal (using external RC circuit) GSM0308PB001 34 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 13 shows a typical connection from an external processor to the Enfora Enabler III-G module, using the external PWR_CTL_SIGNAL solution. The Enfora Enabler III-G can be powered on by using the PWR_CTL_SIGNAL signal. When using PWR_CTL_SIGNAL, the I/O or serial lines can be at any voltage state desired. It is suggested that the I/O and serial lines be tri-stated or set low when the GSM0308 is shutdown for an extended period of time to conserve power. Figure 13 - Power Control Signal (using external processor) GSM0308PB001 35 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Figure 14 shows a typical power-on sequence for the CPU to Enfora Enabler III-G interface. Note that Reset is not used, and the I/O and serial voltage levels are not a concern. Figure 14 - Typical Power On Sequence (using external processor) PARAMETER VIL PARAMETER / CONDITIONS Input Voltage – Low or float MIN VIH Input Voltage – High 0.7 x VBAT ON Pulse Duration OFF Pulse Duration GSM0308PB001 TYP MAX 0.3 x VBAT VBAT 500 Programmable 36 1000 UNIT Vdc Vdc mS 1000 Version DRAFT – 2/9/2007 mS Enfora Enabler III-G Modem Integration Guide 6.6.4. Level Translation Reference Power (Pin 77) To be used as a voltage reference source ONLY. Do not connect current loads to this pin. This pin must be decoupled to ground with at least a 0.1 μF capacitor at the output. Noise induced on this pin will affect the performance of the baseband. VR I/O Parameter/Conditions Output voltage VOUT Rated output current IOUT 6.6.5. ON mode LOW POWER mode ON mode LOW POWER mode Min 1.65 1.65 Typ 1.8 1.8 Max 1.95 1.95 Units Vdc 20 0.5 mA USB (Pins 1, 3, 5, 7, 9) Pin Name USB_VBUS Pin Number 1, 3 Signal Direction In Description 5 V tolerant power Supply VBUS line; Used only as a USB sense, not for powering the module. (optional connection) USB_DP/RXD/MIC_R Analog I/O 5 V tolerant data plus pin in USB modes / Receive function in UART mode / USB_DP Analog I/O ID_USB Analog I/O 5 V tolerant data minus pin in USB modes / Transmit function in UART mode / Monaural speaker or left speaker in AUDIO mode 5 V tolerant ID line, it defines the type of device connected to the phone’s USB port; And also the default state (host / device) at the cable connection; The transceiver senses the voltage of this pin to determine if the pin is either floating (typical),grounded or resistively connected to ground (102 kΩ, 200 kΩ, 440 kΩ); Microphone or right speaker in AUDIO mode The universal serial bus (USB) device controller supports the implementation of a full-speed (FS) device compatible with the Universal Serial Bus Specification Revision 2.0 and the Universal Serial Bus Specification Revision 1.1. The module includes a Universal Serial Bus (USB) transceiver with a car-kit detection, able to support USB 12 Mb/s Full-Speed (FS) and USB 1.5 Mb/s Low-Speed (LS). When a USB cable is plugged into the USB receptacle, the transceiver detects the cable’s presence on VBUS (> 1.8 V) and ID (≠ float) pins, even if the module is switched off. The transceiver is fully operational only in phone’s Active mode. The modules device’s car kit is developed based on CEA-936-A rev.39 – Nov. 24th 2004 specification. Currently the device does not support other versions of this specification. Compared to the CEA-936-A rev.39 – Nov. 24th 2004 specification, the car-kit implementation in the module device does not support [1] a fully implemented hardware Phone State Machine, [2] the relative interrupts and registers for the proper behavior of the Phone State machine and [3] the Data-During- Audio signaling mode. GSM0308PB001 37 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide • USB transceiver full compliant (modes and registers); • Supports data line (D+, D-, and VBUS pulsing session request (SRP); • Supports UART signaling (From 9.6 kbaud up to 115.2 kbaud); • Supports AUDIO (MONO / STEREO) signaling; • Transceiver does not support USB High Speed (HS) mode signaling; There are 3 signal modes available to the USB port that will allow the desired signal to be routed to the physical USB pins. The functions that can be selected are USB mode, UART mode, and AUDIO mode. UART Mode When the UART mode is enabled, UART transactions can be achieved through the transceiver. In this mode, the transceiver can be considered as simple levels translators. When UART mode is enabled, it automatically switches off the other USB and AUDIO drivers. AUDIO Modes It is possible to select between the MONO and STEREO signaling modes. When enabling the AUDIO drivers, the USB and UART drivers are turned off. USB Power (pins 1,3) Filtering Capacitor Filtering Capacitor ESR Input Voltage VIN Parameter/Conditions Connected from VRUSB to GNDD Min 1.0 ON mode, in regulation 2.7 B-Device (SRP Capable, Peripheral-Only) Average 0 V ≤ VBUS ≤ 5.25 V Typ 4.7 5.0 Max 300 5.25 Units µF mΩ Vdc mA Current VBUS Wake-Up Threshold 1.6 1.8 2.0 Typ 4.65 Max 5.25 Units 3.3 3.6 Vdc 0.1 0.3 Vdc μA Max Units Vdc 0.8 Vdc 5V Tolerant Transceiver USB Input Voltage Parameter/Conditions Min Output voltage High (Driven) Low 4.4 2.8 0.0 -2 Transceiver D+/- Leakage Current USB / UART mode Input Levels Parameter/Conditions Min Serial Interface Input High RXD Input High On D+ Serial Interface Input Low RXD Input Low On D+ GSM0308PB001 Typ 2.0 38 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Output Levels Parameter/Conditions Min Serial Interface Input High RXD Input High On DSerial Interface Input Low RXD Input Low On D- ISOURCE = 4 mA 2.4 Typ 3.3 Max 3.6 Units Vdc ISOURCE = -4 mA 0.0 0.1 0.4 Vdc Terminations Phone Microphone Input Impedance Phone Speaker Output impedance Current Parameter/Conditions Freq = 1 kHz Min Typ Max Units kΩ Freq = 1 kHz 200 Ω Phone Speaker Source Current Input Levels D ± grounded 20 mA USB port / Audio mode 10 Phone Microphone Input Range Output Levels 1.0 2.2 Phone Speaker Output Bias 0.7 1.6 2.2 Phone Speaker Output Range 6.6.6. LED A (Pin 8) & B (Pin 6), VRWLED (Pin 10) Pin Name LED A LED B Pin Number Signal Direction Description LED A open drain input LED B open drain input The LED ‘driver’ pins are able to operate as a general current sink, or use in conjunction with the built in LED driver VRWLED. Two white-LEDs drivers are available from the module. The first driver, “LED_A” is dedicated for the screen backlight and can drive up to four white-LEDs in series. The second driver, “LED_B” is dedicated for the keypad and can drive up to four white-LEDs in series. The two white-LEDs driver series are fed by a dedicated DC-DC step-up regulator VRWLED. The maximum current delivered by this white-LEDs drivers is 63.75 mA, in order to have an average maximum current within each white-LED of 21.25 mA . The 63.75 mA is switched among the three series of LEDs as described in the below table, the corresponding timing scheme is reported in the below table. Each series of LEDs has a maximum average current per frame of 21.25 mA ( 63.75 mA ). The frame period is 3×TCK. TCK can be programmed via a register between 2 ms and 6 ms. The current delivered to each series of white-LEDs is obtained from a dedicated 8-bit DAC-based system. While the 4-LSBs contribution is generated starting from a PWM signal that modulates a 4 mA current level as indicated in the below table. GSM0308PB001 39 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Input Code Number Input Code Average Current (mA) 255 (MAX) 254 11111111 11111110 21.25 21.17 … 240 239 … 11110000 11101111 … 20 19.92 … 15 14 13 12 11 10 0 (MIN) … 00001111 00001110 00001101 00001100 00001011 00001010 00001001 00001000 00000111 00000110 00000101 00000100 00000011 00000010 00000001 00000000 … 1.25 1.17 1.08 1.00 0.92 0.83 0.75 0.67 0.58 0.50 0.42 0.33 0.25 0.17 0.83 White-LEDs Drivers 8-bit DAC Input Code, Output Current The DC-DC step-up is based on a control loop, which is composed of a start-up circuit and an amplifier in series with a comparator. Another dedicated logic is capable to sense if one of the two white-LEDs series does not work properly (open circuit): this logic prevents the divergence of the circuit, forcing a low-voltage level on the gate of the power NMOS transistor in this case. During the normal operation, the NMOS transistors drivers, which are part of the feedback system of the boost, remain saturated with a nominal drain-to-source voltage closed to 1.2 V. VBAT POUT 2 LEDs (mW) POUT 3 LEDs (mW) POUT 4 LEDs (mW) 5.5 5.4 5.2 5.0 4.8 4.6 4.4 4.2 4.0 3.8 3.6 3.4 3.3 586 586 586 586 586 586 586 586 586 586 586 586 586 873 831 812 799 755 683 637 606 583 535 468 425 401 824 834 767 710 645 572 523 487 457 424 377 330 304 GSM0308PB001 40 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide VBAT (V) 3.6 6.6.7. Max current (mA) 3 LEDs 40 2 LEDs 64 4 LEDs 25.5 LED VRW (Pin 10) The VRWLED voltage regulator is a step-up DC-DC converter supplying the White LEDs (20.0V/60mA). The regulated voltage depends on the number of series White-LEDs. The main battery directly supplies VRWLED. VRWLED Voltage out Current Parameter/Conditions Min Typ Max 20 60 Units Vdc mA L = 2.2 μH ± 20%, RDC max = 100 mΩ, C = 2.2 µF ± 20% , Zener 20 V Iz typ = 5 mA (min: 4 mA, max: 10 mA), Pd typ = 0.3 W (min: 0.25 W, max: 0.5 W); Figure 15 – LED voltage driver circuit GSM0308PB001 41 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.8. General Purpose Input/Output Interface GPIO number GPIO 1 GPIO 2 GPIO 3 GPIO 4 GPIO 5 GPIO 6 GPIO 7 GPIO 8 Pin number 64 62 60 58 68 70 66 72 Secondary function Pulse Width Tone USB Boot Light Output PWM Transmit active / LED Pulse Generator SPI Chip Select 0 SPI Strobe Enable SPI RnW SPI Data/Control Select Each general-purpose signal may be selected as inputs or outputs. GPIO1-GPIO8 may be used independently as a user-specified function, or may be used to provide modem control and status signals. Several examples of modem control signals are: power shutdown command, register/deregister on network command, and transmitter disable. Several examples of modem status signals are: registration status and ready-for-power-down status to be used with power shutdown command signal. I/O Lines VIL VIH VOL VOH IOL / IOH Parameter/Conditions Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Rated Output Current Min 1.11 Typ Max 0.60 1.8 0.45 1.26 Units Vdc Vdc Vdc Vdc mA Additional GPIO is available as alternate functions of the blocks listed. If the function is selected as a GPIO block then all associated pins will become GPIO, the primary function will be disabled. Electrical specifications for alternate GPIO functions will be the same as their primary pin function. Primary Function MSCI Primary Function Name MCSI_CLK MCSI_FSYNC MCSI_TX MCSI_RX SPI_CLK SPI_MISO SPI_MOSI SPI_CS0 SPI_CS1 SPI_CS2 SPI Pin Number 14 16 18 12 30 26 22 24 28 20 GPIO Number GPIO 9 GPIO 10 GPIO 11 GPIO 12 GPIO 13 GPIO 14 GPIO 15 GPIO 16 GPIO 17 GPIO 18 Some functions have a secondary output that can only be defined as either an input or an output. Primary Function Keyboard Primary Function Name KBR_0 KBR_1 KBR_2 KBR_3 KBR_4 KBC_0 KBC_1 KBC_2 KBC_3 KBC_4 Pin number 38 40 42 36 34 27 33 29 31 32 Signal Direction IN IN IN IN IN/OUT OUT OUT OUT OUT IN/OUT GPIO number GPI 21 GPI 22 GPI 23 GPI 24 GPIO 19 GPO25 GPO26 GPO27 GPO28 GPIO 20 *SPI, I2C, MCSI and Keyboard are for hardware reference only. There is no generic firmware to support these functions. Firmware must be added to enable these functions (TBD) GSM0308PB001 42 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.9. Power Control (Pin 35) The input is equivalent to the “phone ON-button”. A falling-edge on this Active-Low input will switch-ON the module or switch-OFF the module after a delay. This input has a “weak pull-up” resistor internal to the module. This input can be left grounded if the “RTC Sleep Function” is not required. If RTC Sleep is required, see Section 6.6.10. Module Reset VIL VIH IPU ON Pulse Duration OFF Pulse Duration Parameter/Conditions Input Voltage – Low or float Input Voltage – High Internal Pull-Up Resistor Programmable MIN TYP 2.1 -40 25 -31 MAX 0.9 5.5 -15 tbd UNIT Vdc Vdc μA mS mS 6.6.10. RTC Sleep In this mode, the modem is off except for its Real-Time-Clock. When put into this mode, the modem can wake itself up at a designated time/interval. 6.6.11. Serial Interfaces & Handshake (Pins 11, 13, 15, 17, 19, 21, 23, 25) Pin Name UART_TX UART_RX UART_RTS UART_CTS UART_DSR UART_DTR UART_DCD UART_RING Pin Number 15 21 13 11 17 25 19 23 Signal Direction Description Serial data output Serial data input Request to send Clear to Send Data set ready Data terminal ready Data carrier detect Ring detect output Please note that Serial interface is now referenced as a DCE and the naming of pins has changed since Enabler II products GSM0308PB001 43 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide The key features of the UART in the modem mode are as follows: • 16C750 compatibility • Baud rate from 300 bits/s up to 3.6864 Mbits/s • Auto baud between 1200 bits/s and 115.2 kbits/s • Configurable data format: Data bit: 5, 6, 7, or 8 bits Parity bit: even, odd, none Stop bit: 1, 1.5, 2 bit(s) • Hardware flow control RTS/CTS • Software flow control using XON/XOFF characters The Enabler III-G module is designed to be used like a DCE device. Default settings are 8 data, 1 stop, no parity, and 115200 baud. DTR may be used to force the modem into AT command mode from online data mode (See AT Command Document, command AT&D). RTS and CTS may be used for hardware handshaking. DSR is always active (connected to ground) while the modem is on. RING may be used to alert the host to a variety of incoming calls. For a minimal implementation, connect RxData and TxData to the COM port serial data lines, connect DTR and RTS to GND. Serial I/O & Control VIL VIH VOL VOH IOL / IOH Parameter/Conditions Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Rated Output Current Min Typ 1.26 1.26 Max 0.54 1.95 0.54 1.95 2.0 Units Vdc Vdc Vdc Vdc mA 6.6.12. MCSI – Multi-Channel Serial Interface (Pins 12, 14, 16, 18) Pin Name MCSI_RX MCSI_TX MCSI_CLK MCSI_FSYNC Pin Number 12 18 14 16 Signal Direction IO IO Description Serial Data Input Serial Data Output Serial Clock I/O Frame Synchronization I/O The multi-channel serial interface (MCSI) has multi-channel transmission capability. MCSI expand the parallel interface of a MPU or DSP to connect to external devices such as audio codecs and GSM system simulators. The MCSI on the module provides full-duplex communication with master or slave clock control. All transmission parameters are configurable to cover the maximum number of operating conditions: • Master or slave clock control (transmission clock and frame synchronization pulse) • Programmable transmission clock frequency • Single-channel or multi-channel (x16) frame structure • Programmable word length: 3 to 16 bits GSM0308PB001 44 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide • Full-duplex transmission • Programmable frame configuration • Continuous or burst transmission • Normal or alternate framing • Normal or inverted frame polarity • Short or long frame pulse • Programmable oversize frame length • Programmable frame length • Programmable interrupt occurrence time (TX and RX) • Error detection with interrupt generation on wrong frame length GSM digital audio interface (DAI) operating modes (radio uplink, radio downlink, and acoustics). The DAI mode is a GSM test interface that is used to determine the routing of speech data for the devices being tested. In DAI mode, the MCSI is configured for direct connection to the GSM system simulator interface, including the reset system simulator (RSS) signal. For hardware reference only. There is no generic firmware to support this function. Firmware must be added to enable MCSI (TBD) 6.6.13. I2C (Pins 48, 50) Pin Name Pin Number 48 50 I2C_SCL I2C_SDA Signal Direction I/O I/O Description I2C interface Master serial clock I2C interface Serial bi-directional data The multi-master I2C peripheral provides an interface between a local host (LH) such as an MPU processor and any I2C -bus-compatible device that connects via the I2C serial bus. External components attached to the I2C bus can serially transmit/receive up to 8-bit data to/from the LH device through the two-wire I2C interface. This I2C peripheral supports any slave or master I2C -compatible device. The I2C bus is a multi-master bus. The I2C controller supports the multi-master mode that allows more than one device capable of controlling the bus to be connected to it. Each I2C device, including the on board processor, is recognized by a unique address and can operate as either transmitter or receiver, according to the function of the device. In addition to being a transmitter or receiver, a device connected to the I2C bus can also be considered as master or slave when performing data transfers. Note that a master device is the device which initiates a data transfer on the bus and generates the clock signals to permit that transfer. During the transfer, any device addressed by this master is considered a slave. For hardware reference only. There is no generic firmware to support this function. Firmware must be added to enable I2C (TBD) IC VIH VIL II VOH Parameter/Conditions High level input voltage Low level input voltage Input leakage current High level output voltage, IO = 3 mA GSM0308PB001 45 Min Typ Max Units 1.26 1.8 1.9 0.54 ±1 1.44 1.8 μA Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide VOL Iz Low level output voltage, IO = 3 mA Leakage current 0.36 ± 20 μA 6.6.14. Serial Port Interface (SPI) (Pins 20, 22, 24, 26, 28, 30) Pin Number Pin Name SPI_MOSI SPI_MISO SPI_CLK SPI_nCS0 SPI_nCS1 SPI_nCS2 22 26 30 24 28 20 Signal Direction Master Slave Mode mode Description Master Out / Slave In Master In / Slave Out Clock Chip select out / enable Chip select out / enable Chip select out / enable The Master Slave SPI (MSSPI) is compliant with the SPI standard. It is a bidirectional, four-line interface consisting of: • Clock, used to shift-in and shift-out data; • Device enable; • Data input; • Data output; There is one MSSPI module available. It is based on a looped shift register, thus allowing both transmit and receive modes. It can operate in master or in slave mode using MPU / DSP or DMA protocol. In Master mode, the SPI provides up to 3 chip-selects: spi_ncs0, spi_ncs1 and spi_ncs2. In Slave mode, spi_ncs0 is used as the SPI module chip select. For hardware reference only. There is no generic firmware to support this function. Firmware must be added to enable SPI (TBD) SPI VIH VIL VOH VOL II Iout PU PD Parameter/Conditions High level input voltage Low level input voltage High level output voltage, IO = 2 mA Low level output voltage, IO = 2 mA Input leakage current Output current PU resistance PD resistance GSM0308PB001 46 Min Typ Max Units 1.17 1.8 1.9 0.63 1.8 0.45 ±1 μA mA kΩ kΩ 1.35 18 18 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.15. Keyboard (Pins 27, 29, 31, 32, 33, 34, 36, 38, 40, 42 ) Pin Name KBC0 KBC1 KBC2 KBC3 KBC4 KBR0 KBR1 KBR2 KBR3 KBR4 Pin Number 27 33 29 31 32 38 40 42 36 34 Signal Direction Description Keyboard matrix column 0 output Keyboard matrix column 1 output Keyboard matrix column 2 output Keyboard matrix column 3 output Keyboard matrix column 4 output Keyboard matrix Row 0 input Keyboard matrix Row 1 input Keyboard matrix Row 2 input Keyboard matrix Row 3 input Keyboard matrix Row 4 input The module keyboard controller implements a built-in scanning algorithm for hardware-based key press decoding and allows MPU software overhead reduction. The keyboard controller can handle up to 5 × 5 keyboards, operates on a 32 kHz clock, and can generate wake-up events when the device is in sleep mode. The keyboard controller includes the following main features: • Support of multi-configuration keyboards up to 5 rows x 5 columns • Integrated programmable timer • Event detection on both key press and key release • Multi-key press detection and decoding • Long key detection on prolonged key press • Programmable time-out on permanent key press or after keyboard release For hardware reference only. There is no generic firmware to support this function. Firmware must be added to enable Keyboard functions (TBD) Keyboard VIH VIL VOH VOL II Iout PU PD Iz Parameter/Conditions High level input voltage Low level input voltage High level output voltage, IO = 4 mA Low level output voltage, IO = 4 mA Input leakage current Output current PU resistance PD resistance Leakage current GSM0308PB001 47 Min Typ Max Units 1.17 1.8 1.9 0.63 1.8 0.45 ±1 µA mA kΩ kΩ µA 1.35 18 90 ± 20 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.16. VBACKUP Input (Pin 83) The backup battery can be recharged from the main battery. A programmable voltage regulator powered by the main battery allows recharging the backup battery. The backup battery charge starts when the following conditions are met: Backup battery charge is enabled by a control bit: • Main Battery voltage > Backup Battery voltage • Main battery > 2.8 Vdc Note: If the backup battery is not present, the backup battery pin is connected to main battery pin VBACKUP is a power input for the Real-Time-Clock when using RTC-Sleep Function (Section 6.6.10) VBACKUP Input Voltage Range Parameter/Conditions ON mode BACKUP mode, VBAT=0v BACKUP mode, VBACKUP=0v Input Current GSM0308PB001 48 Min 2.5 1.9 1.9 Typ VCC1 VBACKUP VCC2 Max 5.5 5.5 3.0 10 Units Vdc Version DRAFT – 2/9/2007 μA Enfora Enabler III-G Modem Integration Guide 6.6.17. Using VBAK VBAK is a backup voltage that can maintain the RTC clock and alarm functions. If VBAK is not present in the system (intentionally or not) the RTC clock may still be powered if leakage voltage exists on VCC. Otherwise, the RTC clock will lose power and be reset when VCC is restored. PARAMETER PARAMETER / CONDITIONS Backup Voltage (Real-Time-Clock) MIN TYP MAX VBACKUP IBACKUP 2.7 3.0 3.0 4.5 6.0 Backup Voltage for Real-Time-Clock Input Current (VBACKUP = 3.2 V, VBAT = 0 V, No Load on GPIO or Serial Port) UNIT Vdc μAdc VBAK had been tested in the above scenarios and does not contribute to leakage. It will properly provide backup power to the RTC clock. 6.6.18. 32 kHz output (Pin 56) A 32.768 kHz signal is available as an output from the module. This signal should only be used as an input to a high impedance device. Additional loads or capacitance on the line may cause performance issues with the module. If the line is not used, leave floating. 32kHz Clock-Out VIH VIL Maximum capacitor load Maximum resistive load Frequency Parameter/Conditions Min ± 30 ppm Typ Max Units Vdc Vdc tbd pF Ω kHz 32.768 6.6.19. 13 MHz output (Pin 52) A 13 MHz signal is available as an output from the module. This signal should only be used as an input to a high impedance device. Additional loads or capacitance on the line may cause performance issues with the module. If the line is not used, leave floating. 13 MHz Clock-Out VIH VIL Maximum capacitor load Maximum resistive load Frequency GSM0308PB001 Parameter/Conditions Min TBD ±0.1 ppm when registered on GSM network; ±12 ppm typical when not registered; 49 Typ Max 0.3 Units Vdc Vdc TBD pF TBD Ω MHz 13.000 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.20. Analog-To-Digital Input (Pin 74) The monitoring ADC (MADC) consists of a successive approximation 10–bit analog–to–digital converter (ADC). Analog-To-Digital Input ADCBRES ADCREF VADC Integral/Differential NonLinearity Input Leakage Retuning Frequency Parameter/Conditions ADC Binary Resolution ADC Reference Voltage ADC Range Min Typ Max 10 1.75 -2 1.75 Units Bits Vdc Vdc LSB μA MHz tbd 6.6.21. Handset Microphone Input (Pins 65, 67) The handset differential inputs MICIP and MICIN can be amplified by the differential handset microphone amplifier. This amplifier has a gain of 25.6 dB and a bias generator MICBIAS provides an external voltage of 2 V or 2.5 V to bias the microphone. Handset Mic Input Maximum Input Range – Mic(+) to Mic(-) Nominal Ref. Level – Mic(+) to Mic(-) Differential Input Resistance – Mic(+) to Mic(-) Microphone PreAmplifier Gain Parameter/Conditions Inputs 3 dBm0 (Max. digital sample amplitude when PGA gain set to 0 dB) Min Typ Max 32.5 Units mVRMS Differential MIC -10 dBm0 Differential MIC, MICAMP gain = 25.6 dB (INMODE = 0001) 36 kΩ 25.6 dB Differential MIC 6.6.22. Handset Microphone Bias Output (Pin 63) Mic Bias Output Parameter/Conditions Bias Voltage on Mic(+) Set to 2.0 V Set to 2.5 V Min 1.9 2.4 Mic Bias Current Capability GSM0308PB001 50 Typ Max 2.1 Units Vdc 2.6 Vdc 2.0 mA Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.23. Handset Speaker Output (Pins 71, 73) Pin Name Pin Number Signal Direction Description EARP EARN 71 73 Earphone positive output Earphone negative output The earphone amplifier provides a full differential signal on the terminals EARP and EARN (Earphone). Handset Spkr Output Maximum Differential Resistive Load Maximum Differential Capacitive Load Common Mode Minimum Resistive Load Common Mode Maximum Capacitive Load Amplifier Gain Parameter Earphone output swing at EARP-EARN Earphone amplifier gain Earphone amplifier state in power down Earphone amplifier power supply rejection Parameter/Conditions Output Swing 3.9 VPP Output Swing 1.5 VPP Min Typ Max Units Ω 120 Ω pF 33 100 200 At Internal Speaker (+) or (-) kΩ 50 At Internal Speaker (+) or (-) EARG = 1 EARG = 0 pF -11 Test Conditions Distortion ≤ 2% and 120 Ω, VSP input level = +3 dBm0, amp gain = -11 dB Distortion ≤ 2% and 33 Ω, VSP input level = -5.34 dBm0, amp gain = -11 dB Distortion ≤ 2% and 120 Ω, I2S input level = +3 dBm0, amp gain = -11 dB Distortion ≤ 2% and 120 Ω, VSP input level = +3 dBm0, amp gain = 1 dB Distortion ≤ 2% and 33 Ω, VSP input level = -5.34 dBm0, amp gain = 1 dB Distortion ≤ 2% and 120 Ω, I2S input level = +3 dBm0, amp gain = 1 dB EARG = 1 EARG = 0 Min DB dB Typ 0.98 Max Units VP-P 0.38 0.93 3.1 3.92 1.2 1.5 2.96 3.7 -11 High dB dB 50 dB 1 kHz, 100 mVp-p An external audio amplifier should be used for loads of less than 16 Ω or if volume is inadequate. GSM0308PB001 51 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.24. Headset Microphone Input (Pin 55) The headset differential inputs HSMIC and AUXI can be amplified by the differential handset microphone amplifier. This amplifier has two different gains 4.9 dB or 25.6 dB and a bias generator HSMICBIAS provides an external voltage of 2 V or 2.5 V to bias the microphone.Headset Mic Input Maximum Input Range Parameter/Conditions Min Inputs 3 dBm0 (Maximum digital sample amplitude with PGA gain set to 0 dB), AUXAMP gain = 18 dB, Single HSMIC Nominal Ref. Level Microphone PreAmplifier Gain Input resistance at HSMIC Typ Max Units 78 mVRMS -10 dBm0 18 dB 40.5 HSMIC single input, AUXAMP gain = 18 dB (INMODE = 0101) kΩ 6.6.25. Headset Microphone Bias Output (Pin 53) Mic Bias Output Bias Voltage on Mic(+) Parameter/Conditions Min 1.9 Set to 2.0 V Set to 2.5 V 2.4 Mic Bias Current Capability GSM0308PB001 52 Typ Max 2.1 Units Vdc 2.6 Vdc 2.0 mA Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.26. Headset Speaker Output Left & Right (Pins 57, 59) Pin Name HSOL HSOR HSOVMID Pin Number 57 59 61 Signal Direction Description Headset Out 32Ω Speaker Left Headset Out 32Ω Speaker Right Headset Out pseudo ground return The left and right headset amplifiers provide the stereo signal on terminals HSOL and HSOR. A pseudo ground is provided on terminal HSOVMID to eliminate external capacitors. The mono audio signal can be provided on the Right or the Right and Left headset outputs. Headset Spkr Output Parameter/Conditions Maximum Swing Distortion ≤ 2% and 32 Ω, VSP input level = +3 dBm0 Distortion ≤ 2% and 32 Ω, I2S input level = +3 dBm0 Min 1.6 Typ 1.96 1.48 1.85 Maximum Capacitive Load Units VP-P 100 pF Ω 32 Minimum resistive load at HSOL and HSOR: Zload Amplifier Gain HSOL/R amplifier Power supply rejection Max 1 kHz, 100 mVpp Amplifier State in Power Down -5 dB 50 dB High Z The left and right channels of the headset speaker output are a single ended output. An external audio amplifier should be used for loads of less than 32 Ω or if volume is inadequate. 6.6.27. Headset Output Common Mode (Pin 61) The left and right headset amplifiers provide the stereo signal on terminals HSOL and HSOR. A pseudo ground is provided on terminal HSOVMID to eliminate external capacitors. HSOVMID Maximum Capacitor Load Parameter/Conditions DC Level GSM0308PB001 53 Min Typ Max 200 Units pF 1.2 1.35 1.5 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.6.28. Headset Detect (Pin 47) Headset Plug/Unplug detection: • 2 modes: Module already ON (Battery connected, VRIO ON) and plug event; Module OFF and plug event: the plug detection will be effective once VRIO is set ON • Plug and unplug detections are digitally debounced (debouncing time = 8 ms). • The jack plug detection feature is addressed through the HSDET pin. The integrated pull up, connected to the pin, forces a high level (VBAT) when the headset load is not connected. At jack insertion headset load connection (32 Ω) imposes a low level on that node (Headset left channel): as an example HSDET = 1 mV after jack plug for VBAT = 4 V. • Input comparator threshold voltages are defined as VTlow = VBAT/2 – 100 mV and VThigh = VBAT/2 + 100 mV, VBATmin = 3.2 V. The plug and unplug detection remains functional if there is no signal from HSOL amplifier output (stereo path is OFF) or if there is a signal from HSOL (stereo path is ON): maximum level on HSOL when the stereo path is ON is 1 Vp-p which stays far enough from the comparator threshold levels VBATmin/2 – 100 mV and VBATmin/2 + 100 mV. • Jack plug detection is functional if a plug event occurs before the power up of the module or if the plug event occurs after the power up of the module: analog detection part is always active if the battery is connected. Detection interrupts will be generated once the VRIO regulator is power up during the module power up sequence. • A level change on HSDET pin is sensed by a Schmitt trigger to provide a jack detection signal to the audio digital control. The audio digital control receives the detection signal and proceeds to a digital debouncing (time: 8 ms = 256 * 32 kHz clock periods) before sensing that a plug event happened on the jack connector. Headset Detect Parameter/Conditions MIN TYP Low level input voltage VIL related to VBAT UNIT 0.7 * VBAT High level input voltage VIH related to VBAT Current with pull-up GSM0308PB001 MAX 0.3 * VBAT -40 54 -31 -15 Version DRAFT – 2/9/2007 μA Enfora Enabler III-G Modem Integration Guide 6.6.29. Audio Mixer input (Pins 49, 56) The mono FM input (mono FM - VMID) can be amplified by the auxiliary amplifier. This amplifier has a gain of 4.9 dB. The stereo FM inputs can be amplified as well. The FM right channel is amplified by the auxiliary amplifier (FM R - VMID) and the left channel by the handset microphone amplifier (FM L - VMID). The gains are of 4.9 dB. This output is not connected to the ADC input, like the other outputs, but to an audio output stage through a logarithmic PGA gain stage. If the analog input is a stereo signal, the FML input corresponds to the analog left channel input and the FMR/AUXI input corresponds to the analog right channel input. If the analog input is a mono signal, the FMR/AUXI input has to be used only. PARAMETER Parameter/Conditions Maximum Input Range FML Inputs 3 dBm0 (Maximum digital sample amplitude with PGA gain set to 0 dB), MICAMP gain = 4.9 dB, Single FML Inputs 3 dBm0 (Maximum digital sample amplitude with PGA gain set to 0 dB), AUXAMP gain = 4.9 dB, Single FMR (AUXI) Nominal reference level at FML -10 dBm0 Single AUXI/FMR -10 dBm0 Single FML input for FM Stereo (INMODE = 0100) Single AUXIFMR input for FM Stereo (INMODE = 0100) Single AUXI input, low gain (INMODE = 0110) Single AUXI input, high gain (INMODE = 0111) Single AUXI input, AUXAMP gain = 4.9 dB Single AUXI input, AUXAMP gain = 28.2 dB (INMODE = 0111) FM Mono (INMODE = 1000), AUXAMP gain = 4.9 dB FM Stereo (INMODE = 0100), AUXAMP gain from 2.9 dB to 18.9 dB FM Stereo (INMODE = 0100), MICAMP gain from 2.9dB to 18.9 dB 4.9 dB 4.9 dB 4.9 dB 28.2 dB 130.5 kΩ 13.5 kΩ 130.5 kΩ 36 kΩ 36 kΩ Maximum Input Range FMR (= AUXI) Nominal Reference Level at FML Nominal Reference Level at (AUXI/FMR) Micro Amplifier Gain for FML input Auxiliary Amplifier Gain for AUXI/FMR input Input Resistance at AUXI/FMR Input resistance at FML GSM0308PB001 Min 55 Typ Max 353 Units mVrms 353 mVrms Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 6.7. Subscriber Identity Module (SIM) Carrier The SIM, an integral part of any GSM terminal device, is a “smart card” that is programmed with subscriber information: • The user information consists of an International Mobile Subscriber Identity (IMSI) number, which is registered with the GSM provider, and an encryption Ki (pronounced "key"). This information consists of a microprocessor and memory installed on a plastic card. Note: The SIM is not provided with the Enfora Enabler III-G module. The SIM must be obtained from the GSM service provider and must be provisioned by the operator for data and/or voice. Always take care to protect the SIM: the GSM terminal will not operate without the SIM installed. The SIM provides the IMSI for authentication. To gain access to the GSM network, the network must recognize the IMSI number, and the terminal must be able to properly decrypt the data sent by the network. The SIM also serves as a buffer for SMS messages, storing the message for transmission until a radio link is available and buffering received messages until retrieved. 6.7.1. SIM Integration for the Enfora Enabler III-G Module The Enabler III-G module default configuration does not include an on-board SIM carrier. Enfora provides a separate product SKU for the Enabler III-G module with the integrated SIM carrier. 6.7.2. Using a Remote SIM with the Enfora Enabler III-G Module (Pins 76, 78, 80, 82, 84) The Enabler III-G module default configuration does not include an on-board SIM carrier. The module supports the use of 1.8 V and 3 V SIM cards. The module includes a hardware interface module dedicated to Universal Subscriber Identity Module (USIM). All baud-rates defined in ISO 7816-3 standard are supported for high-speed transmission. The module optionally includes an on-board SIM carrier. All other modules require a remote SIM carrier/connector. If the module is going to be integrated using a remote SIM, the following guidelines are provided: • To utilize a remote SIM, the integrator must provide a suitable SIM connector. • The maximum distance from the module to the remote SIM connector must not exceed 25.4 cm (10 inches). • External ESD Protection is Required; 15 kV Air Discharge; 8 kV Contact Discharge; GSM0308PB001 56 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide <25.4 cm (10 in) Enabler III-G module SIM Interface Remote SIM SIM_VDD SIM_RST SIM_CLK SIM_DTC SIM_I/O Figure 16 - Remote SIM Interface Pin Name SIM_VDD SIM_CLK SIM_RST SIM_I/O SIMDTC Pin Number 76 78 80 82 84 Signal Direction I/O Description SIM VDD Card Reference Clock Card Reset Card I/O Data Card detect The module provides the regulated supply voltage for the SIM-card and the circuitry to detect the insertion or extraction of the SIM-Card in or from the mobile. When the SIM-card is inserted, a mechanical contact connected on the module terminal is tripped and after debouncing, an interrupt is generated. The SIM-card presence detection logic must be active even when the system is in idle mode. Thus, the debouncing logic is based on the 32 kHz low-activity clock. GSM0308PB001 57 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide The signal from SIMDTC is pre-processed depending on the detection system and on the internal pullup/pull-down configuration. USIM VDD Parameter/Conditions SIM VDD voltage VIH VIL VOH VOL II Iout PU PD Iz Card Detect High level input voltage Low level input voltage High level output voltage, IO = 4 mA Low level output voltage, IO = 1 mA Input leakage current Output current PU resistance PD resistance Leakage current Debouncing time (SIM-card insertion) Time unit (SIM-card insertion) Debouncing time (SIM-card extraction) Time unit (SIM-card extraction) Pull-down resistor (resistor + resistive switch) Pull-up resistor (resistor + resistive switch) Min 1.65 2.7 1.15 Typ 1.8 2.85 Max 1.95 2.95 0.61 Vdd-0.45 0.4 ±1 32 30 ± 30 0.5 0.5 0.5 0.5 345 475 6.7.2.1. Remote SIM Component Information A SIM carrier compatible for use on the Enabler III-G module is a Suyin P/N: 254016MA006G103ZL GSM0308PB001 58 Version DRAFT – 2/9/2007 Units μA mA kΩ kΩ μA mS mS mS mS kΩ kΩ Enfora Enabler III-G Modem Integration Guide 7. GSM/GPRS Modes of Operation GSM/GPRS supports many optional services and modes. The Enfora Enabler III-G module supports the following GSM/GPRS services: • Circuit-switched data • Short-Message Services (SMS) • Class B GPRS Functionality • Voice communication 7.1. Enabling the Transmission Modes for the GSM/GPRS Services Each of the GSM/GPRS services has two modes that can be enabled separately: • Mobile-originated (MO): allows the making of a service request (such as, making a telephone call or sending an SMS) • Mobile-terminated (MT): allows receiving a service request (such as receiving a telephone call or an SMS) Note: Contact your local GSM operator to ensure that the services and modes have been provisioned for the SIM. 7.2. Voice Communication The Enfora Enabler III-G module has full voice capabilities, provided the necessary connections have been made for the speaker and microphone pins on the 100-pin I/O connector. The Enfora EnablerIII-G AT Command Set Reference - GSM0308PB001MAN has the entire list of commands that can be used to control the voice functionality. The quick start guide in this manual provides a basic command set that can be used to initialize and test the voice functionality. The Enfora Enabler III-G module supports three vocoder compression algorithms for voice communication: Full-Rate (FR), Enhanced Full-Rate (EFR), and Half-rate (HR). 7.3. Circuit-Switched Data In this mode, the Enfora Enabler III-G module supports both of the connection modes of transmission that are provided by GSM: • Non-Transparent mode delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed Public Switched Telephone Network (PSTN) line. Note: All GSM service providers may not support transparent mode. In those cases, the Enfora Enabler III-G module can be configured to switch automatically to Non-Transparent mode. This capability depends on the settings in the AT+CBST command. GSM0308PB001 59 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 7.4. SMS: Short Message Services • Short Message Services (SMS) is a feature-rich GSM service. The Enfora Enabler III-G module can perform the following tasks: • Sending and receiving binary messages of up to 160 characters (7-bit characters) • Sending and receiving text messages of up to 140 bytes (8-bit data) • Submitting a SMS Protocol Data Unit (PDU) to a SMSC (Short Message Service Center) and storing a copy of the PDU until either a report arrives from the network or a timer expires • Receiving a SMS PDU from a SMSC • Returning a delivery report to the network for a previously received message • Receiving a report from the network • Notifying the network when the module has sufficient memory capacity available to receive one or more SMS messages (after the module had previously rejected a message because its memory capacity was exceeded) GSM0308PB001 60 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 8. SIM Operation 8.1. Provisioning the SIM The SIM can support optional features or services. Most operators typically configure the SIM to send/receive voice calls and to receive SMS; however, some may require an additional tariff to enable the SIM to send SMS. The transmission of circuit switched and GPRS data are also additional services that may be required to allow the service: • Mobile-originated (MO): allows making a service request (such as, making a call or sending an SMS) • Mobile-terminated (MT): allows receiving a service request (such as, receiving a phone call or an SMS) It is imperative for the Enfora Enabler III-G module that the SIM be configured for the optional services that are required for the application. 8.2. GSM Services Supported by the Enfora Enabler III-G Module The Enfora Enabler III-G module supports four GSM services (modes of operation) that must be enabled by the operator: • Voice calls (MO and MT): requires a telephone number • SMS (MO and MT): uses the telephone number for Voice • Circuit-switched data calls (MO and MT): requires a telephone number • The GSM SIM can have multiple telephone numbers. 8.3. GPRS Services Supported by the Enfora Enabler III-G Module The Enfora Enabler III-G module supports the following GPRS (modes of operation) that must be enabled by the operator: • GPRS Packet Connectivity (MO and MT) with Both Dynamic and Static IP option • GPRS SMS (MO and MT): uses the IP (Dynamic or Static) set by the operator • Multiple APN Setting • Quality of Service Options • Multi-slot 10 Class of Service GSM0308PB001 61 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 8.4. Selecting the GSM Modes of Operation When provisioning the SIM for the Enfora Enabler III-G module, enable the following modes of operation: • Voice calls: configure the SIM for both MO and MT service (to send and receive) • SMS: configure the SIM either for MT alone (to receive) or for both MO and MT (to send and receive) • Circuit Switched Data: configure the SIM either for MO alone (to send) or for both MO and MT (to send and receive) Voice MO/MT MO/MT MO/MT SMS MT MO/MT MO/MT GSM0308PB001 CS Data MO MO MO/MT GPRS Function Voice calls, receive SMS, make data calls Voice calls, receive / send SMS, make data calls Voice calls, receive / send SMS, make / receive data calls (requires an additional data telephone number) 62 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9. Software Interface 9.1. Software Interface The application sends commands to the Enfora Enabler III-G module via the 100-pin I/O signal connector. These commands use the Enfora AT Command Set and/or Enfora’s Packet API. The Enfora Enabler III-G module operates in one of the following modes: • Command mode: Used for configuring the Enfora Enabler III-G module, for interrogating the GSM network, and for placing and receiving calls. It uses the AT command set via the serial port for communication. • On-line mode: Used after a circuit-switched data call has been established. Data is passed between the Enfora Enabler III-G module and the controlling application without command interpretation. The only AT command that is interpreted in On-line mode is the +++ command. (This command places the Enfora Enabler III-G module in Command mode but does not terminate the circuit-switched data call.) • IP Packet /API Mode: Used to read/write modem parameters, interrogate network information, and place and receive calls in real-time, multi-tasking mode. The Packet API mode is facilitated over a PPP connection and the packets can be constructed according to the information provided in the Enfora GSM-GPRS Family API Reference GSM0102PB002MAN. Enfora GSM-GPRS Family Modem Control Library Reference GSM0000PB006MAN provides detail of the UDP Modem Control Library that has three levels: port, messaging, and modem libraries. Each of the three levels contains one or more libraries. For example, the port libraries layer has UDP PPP Port, UDP Socket Port, and COM Port libraries. All libraries are provided as a part of the Enfora Enabler III-G Module Integration Toolkit. The AT command driver of the Enfora Enabler III-G module never exits the Command state, that is, it never enters the On-line mode. Although the host interface may not be able to access the AT command interpreter, it is always running and is available via the API Mode over a PPP connection and/or via the RF interface. • In the Command state, characters that are received from the Customer Premise Equipment (CPE) are treated as AT commands by the Enfora Enabler III-G module. • In response to the commands received from the CPE, the Enfora Enabler III-G module sends characters (AT commands) to the CPE. • Various events can also trigger the Enfora Enabler III-G module to send characters (AT commands) to the CPE. GSM0308PB001 63 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9.2. Format for the AT Commands The general format of the command line is:AT See AT Command Manual 0X0D The prefix AT obtains synchronization, identifies the character parameters, and indicates that a command may be in the following characters. AT commands are not case sensitive: use either capital letters or lower-case letters for the AT command. Note: Some AT Command parameter values ARE case sensitive and are documented in the Enfora Enabler-IIG AT Command Set Reference - GSM0107PB001MAN. GSM0308PB001 64 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9.3. Enfora AT Command Set For a full description of the AT commands, refer to the Enfora Enabler-III AT Command Set GSM0308PB001MAN. Note: A command description that includes an *asterisk denotes that the GSM service provider must enable supplementary services functionality before the command is available. 9.4. Enfora Packet Application Programming Interface 9.4.1. UDP-API Architecture The following information provides an overview of the Enfora UDP-based API architecture. Full details are provided in the Enfora GSM-GPRS Family UDP-API Reference GSM0102PB002MAN. Figure 18 provides the general structure for the UDP-API. Figure 17 - UDP-API Structure GSM0308PB001 65 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide The following provides information related to the general construction of the UDP-API packet. Other command structures are available and can be found in the API reference manual. All AT commands listed in the GSM0308PB001MAN document are supported via this method. To send an AT command via DUN or OTA, the user has to follow the following message structure. This message structure sends the ATI command to the modem and receives Enfora, Inc. response from the modem. Bytes 0 – 19 20 – 27 28 29 30 31 32 33 34 Data Description IP Header UDP Header 0x00 0x01 0x04 0x00 0x41 0x54 0x49 Comments Sequence Number AT Command Read/Write Reserved AT Command (ATI) Following data will be returned by the modem: Bytes 0 – 19 20 – 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 GSM0308PB001 Data Description IP Header UDP Header 0x00 0x01 0x05 0x00 0x0D 0x0A 0x45 0x6E 0x66 0x6F 0x72 0x61 0x2C 0x20 0x49 0x6E 0x63 0x2E 0x0D 0x0A 66 Comments Sequence Number AT Command Response Reserved AT Command Response (Enfora, Inc.) Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9.5. Enfora Modem Control Library Architecture The following information provides an overview of the Enfora Modem Control Library architecture. Full details are provided in the Enfora GSM-GPRS Family Modem Control Library Reference GSM0000PB006MAN. Figure provides the general embedded architecture for the Enabler III-G modem. There are various levels of access provided to allow complete application design flexibility. SLIP access is not currently available. Figure 18 - Library Layout UDP Modem Library with UDP Messaging Library with UDP Modem Library with UDP Modem Library with UDP Messaging Library with UDP Messaging Library with UDP Socket Port Library UDP PPP Port Library UDP SLIP Port Library The table below can be used to help decide which library configuration is the best for a project. SLIP access is not currently available. Benefits Allows dynamic IP assignment Allows multiple application to access the modem Allow AT Commands Allows modem control message Provide modem control message formatting Provides modem parameters database service Suitable for microcontroller programming Requirements GSM0308PB001 67 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Requires TCP/IP stack Memory usage Low Low Low Low Low Low High High High Table 3 - Modem Library Configurations 9.5.1. Using Port Library Figure provides the architecture for Port Library access. Figure 19 - Using Port Library Port Libraries provide the most basic modem access services. It converts modem control messages to either UDP SLIP or UDP PPP, and vice versa. SLIP access is not currently available. Modem Control Message SLIP Header IP Header UDP Header Modem Control Message SLIP End Modem Control Message PPP End Or PPP Header 9.5.2. IP Header UDP Header Using Messaging Library Figure provides the architecture for Messaging Library access. Figure 20 - Using Messaging Library GSM0308PB001 68 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Messaging Library provides some important modem access services. It builds a modem control message and converts the message to either UDP SLIP or UDP PPP before sending the data to the modem. It also parses the modem control messages from the modem. SLIP access is not currently available. Parameter, Data SLIP Header IP Header UDP Header PPP Header IP Header UDP Header Modem Control Message SLIP End Or GSM0308PB001 Modem Control Message 69 PPP End Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 9.5.3. Using Modem Library Figure provides the architecture for Modem Library access. Figure 21 - Using Modem Library Modem Library provides the most complete modem access services. In addition to the features already provided by the Messaging Library, the modem library maintains a modem parameter database. In order to maintain the parameter database, the modem library requires more memory than the other libraries. This makes the library unsuitable for some of the micro controller programming. However, it is a good library to use by applications in a personal computer or a PDA. It allows the programmer to develop host applications for the modem quickly. 10. Setup and Initialization 10.1. General Setup The GPRS modem is controlled through the Modem RS232 port on the development board. Connect a nine pin straight through serial cable from the Modem RS232 connector to the serial port on the controlling computer. Hook up power supply, connect antenna, and install SIM into modem. 10.1.1. HyperTerminal Configuration for Enabler III-G module The following provides an example for setting up a Windows HyperTerminal session that can be used to experiment with various configurations on the Enabler III-G module for controlling computer: GSM0308PB001 70 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 1. Select the connection interface, Direct to Com 1 (or whatever port is the serial port). Figure 22 - HyperTerminal Definition GSM0308PB001 71 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 2. Configure the COM port as displayed below. Figure 23 - COM Port Settings 10.1.2. Initialization (AT Command Interface) In the GSM vocabulary, a call from GSM mobile to the PSTN is called a "mobile-originated call" or "outgoing call". A call from the fixed network to a GSM mobile is called a "mobile-terminated call" or "incoming call." In the following examples, “Entry” refers to the application. The following convention describes the direction of the data exchange: • The data exchange from the customer application to the Enfora Enabler III-G module is designated as: Entry The data exchange from the Enfora Enabler III-G module to the customer application is designated as: Response Note: With the exception of the +++ command (Online Escape Sequence), all commands must be preceded by the AT attention code (or command prefix) and terminated by pressing the character. GSM0308PB001 72 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide In the following examples, the and are intentionally omitted for clarity and space. 10.1.3. Initial Response to the AT Command After power is applied to the Enfora Enabler III-G module, the module performs a power-up selftest. The self-test completes within one (1) second. When queried with the AT command, the Enfora Enabler III-G module responds with one of the following result codes: • OK signifies that the Enfora Enabler III-G module is ready, that it correctly interprets the AT command, and that it has executed the command. • ERROR signifies that the Enfora Enabler III-G module does not understand the command or that the command is invalid. Entry Response AT OK Command valid: module is ready The Enfora Enabler III-G module must be in AT Command mode (please refer to section 10.3 GPRS Packet Examples for packet mode initialization and setup) when any command is entered (with the exception of the online escape sequence). Commands entered when the module is in On-line mode are treated as data, and are transmitted as such to the receiving module. i.e. If the module is in PPP or SLIP mode, AT commands cannot be entered. 10.1.4. Sending an Initialization String to the Enfora Enabler III-G Module The following example provides the sample AT commands and responses for the following initialization tasks: • Reset the module to the factory defaults • Disable character echo • Transmit Result Codes • Set the module to Verbose mode (to display result codes as words) • Set the DCD to match the state of remote modem • Ignore the DTR Entry Response Entry Response AT&FE0Q0V1&C1&d0 OK ATSO=1 OK GSM0308PB001 Initialization string Command is valid Auto answer on 1st ring Command is valid 73 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 10.1.5. Setting Up the Communication Mode for the Enfora Enabler III-G Module The following example sequence provides the AT command and response for setting the Enfora Enabler III-G module for full phone functionality, automated operator selection, 9600 baud, nontransparent mode. Entry Response Entry Response Entry Response AT+CFUN=1 OK AT+COPS=0 OK AT+CBST=7,0,1 OK GSM0308PB001 FULL phone functionality Command is valid Automatic operator selection Command is valid 9600 baud, non-transparent mode Command is valid 74 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 10.1.6. Querying the Status of the Enfora Enabler III-G Module This topic is addressed in the Enfora Application Note GSM0000AN006 – Enabler-G Module Status Query. 10.1.7. Setting Module Reporting Parameters for GSM and GPRS This topic is addressed in the Enfora Application Note GSM0000AN007 - Enabler-G Status Reporting. 10.2. GSM/SMS Examples 10.2.1. Initialize the Enfora Enabler III-G Module to Send and Receive SMS Text Messages This topic is addressed in the Enfora Application Note GSM0000AN004 - Enabler-G SMS Configuration and Use. 10.2.2. Managing SMS Messages This topic is addressed in the Enfora Application Note GSM0000AN004 - Enabler-G SMS Configuration and Use. 10.2.3. Data Call Configuration This topic is addressed in the Enfora Application Note GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use. 10.2.4. Voice Call Configuration This topic is addressed in the Enfora Application Note GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use. 10.3. GPRS Packet Examples 10.3.1. GPRS ATTACH and ACTIVATE This topic is addressed in the Enfora Application Note GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use. 10.3.2. Windows PPP Setup The Enabler III-G module can be used in a Windows operating system environment as a standard serial modem device. The required setup and configuration process is contained in Enfora Application Notes GSM0000AN001 - Enabler-G PPP Configuration for Windows 98 and GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000. GSM0308PB001 75 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 11. Integration and Testing The Enfora Enabler III-G module has been designed to minimize the amount of time required for integration and testing the application. By being fully certified by the appropriate bodies, the Enfora Enabler III-G module provides seamless integration into the GSM network. The integration issues for the application can be narrowed to the utilization of the AT commands and the use of the GSM functionality. Coverage and signal quality may be evaluated by using the RSSI commands. Additional network information can be determined by using AT commands. Integration of the GPRS Packet capabilities is more complicated than using AT command sequences to initiate the connection and begin transferring data. The following Application Notes should be used to integrate the GPRS packet capabilities: GSM0000AN001 - Enabler-G PPP Configuration for Windows 98 GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000 GSM0000AN008 - Enabler-G PPP Configuration for Windows XP GSM0000AN010 - Enabler-G PPP Configuration for PocketPC 2002 GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use 11.1. Integrating the Enfora Enabler III-G Module Note: Generally, all interfaces that are externally available to the end user need to be ESDconditioned and terminated in some way. Many of these interfaces should not be connected with power applied. At the highest level, this is done using some type of GSM test equipment (such as, Racal 6103E), a computer, and a serial interface tester. The GSM test equipment must be able to simulate a GSM call and measure the key parameters related to the module. Additionally, the serial interfaces and some minimal SIM functionality can be verified by sending AT commands to the Enfora Enabler III-G module. All of these conditions need to be verified at ambient as well as extreme conditions. GSM0308PB001 76 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide As part of integration, each of the following interfaces must be verified: Information SIM Recommendations The maximum line length of the SIM interface is 25.4 cm (10 inches). The Enfora Enabler III-G module takes care of the signal conditioning As a minimum, an external application with a remote SIM will require a standard SIM carrier. Filter the SIM VCC signal with a 10 uf / 10 V capacitor to help with the line length. Primary and secondary serial Interfaces Reset Interface Audio/Microphone Interface GSM0308PB001 The Enfora Enabler III-G module uses a 1.8/3 V digital interface. The RS232 signals must be level-shifted to get standard levels. These signals must be ESD-protected. Resets the Enfora Enabler III-G module when tied low. Preliminary balancing on Enfora Enabler III-G module. Maximum length TBD 77 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Testing the following parameters verifies the RF parameters that may be affected by such things as RF path loss, power supply noise, and external interference. Functionality Transmitter Receiver Parameters to be Tested Frequency Error Phase Error PA Ramp Modulation Spectrum RF Power Steps Timing Advance BER Based RX Tests (RXQUAL RXLEV) BER Based Sensitivity Testing the following GSM functionality verifies proper network communication. Functionality Transmitter Receiver Parameters to be Tested Frequency Error Phase Error PA Ramp Modulation Spectrum RF Power Steps Timing Advance BER Based RX Tests (RXQUAL RXLEV) BER Based Sensitivity Testing the following GSM functionality verifies proper network communication. Functionality Network Function Parameters to be Tested Synchronization and registration Call set-up and call termination (both MT and MO calls) SMS and/or data calls GSM0308PB001 78 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 12. APPENDIX A LIMITED WARRANTY 12.1. Scope Enfora warrants to the original purchaser of the product that, for a period of one (1) year from the date of product purchase, the product hardware, when used in conjunction with any associated software (including any firmware and applications) supplied by Enfora, will be free from defects in material or workmanship under normal operation. Enfora further warrants to such original purchaser that, for a period of ninety (90) days from the date of product purchase, any software associated with the product will perform substantially in accordance with the user documentation provided by Enfora, and any software media provided with the product will be free from defects in material or workmanship under normal operation. Enfora does not warrant that (a) the product hardware or any associated software will meet the purchaser’s requirements, (b) that the operation of the product hardware or software will be uninterrupted or error-free, or (c) the product, when integrated in, or combined with, other products or software not supplied by Enfora, will continue to perform substantially in accordance with the user documentation. This limited warranty is only for the benefit of the original purchaser and is not transferable. No other party may act on behalf of such purchaser for the purpose of claiming or exercising any rights or benefits under or in connection with this limited warranty except as may be provided in a written agreement between Enfora and such other party. 12.1.1. Hardware During the warranty period applicable to the product hardware, Enfora, at its expense and in its sole discretion, will repair or replace the product if it is determined to have a covered hardware defect, provided that the purchaser first notifies Enfora of any such defect, furnishes Enfora with a proof of purchase, requests and obtains a return merchandize authorization (RMA) number from Enfora, and returns the product, shipping charges prepaid, to Enfora under that RMA. If, upon reasonable examination of the returned product, Enfora does not substantiate the defect claimed by purchaser, or determines that the defect is not covered under this limited warranty, Enfora will not be required to repair or replace the product, but may instead reship the product to the purchaser, in which case purchaser shall be responsible for paying Enfora’s usual charges for unpacking, testing, and repacking the product for reshipment to purchaser. Purchaser shall bear the risk of loss or damage in transit to any product returned by purchaser to Enfora, or any returned product not found to be defective or covered under this warranty and reshipped by Enfora to purchaser. In the event Enfora repairs or replaces a defective product, the repaired or replacement product will be covered under this limited warranty for the remainder of the original warranty period on the defective product. If Enfora is unable to repair or replace a defective product, the purchaser’s exclusive remedy shall be a refund of the original purchase price. Any returned and replaced product, or any product for which Enfora has refunded the original purchase price, becomes the property of Enfora. 12.2. Software During the warranty period applicable to the software or its media, Enfora, at its expense, will replace any defective software or media if purchaser gives written notification of the defect to the technical support department at Enfora during the applicable warranty period. Enfora will ship or otherwise transmit the replacement software or media to purchaser, and purchaser shall be responsible for incorporating any replacement software in the product. Enfora shall not have any obligation to provide any software bug GSM0308PB001 79 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide fixes, upgrades or new releases except as may be necessary to correct any covered defect of which purchaser notifies Enfora in writing during the applicable warranty period. Enfora, from time to time and in its sole discretion, may make available for download on its website (www.enfora.com) certain software bug fixes, upgrades or new releases for the product. The purchaser should periodically visit such website to determine whether any such bug fixes, upgrades or new releases have become available. Download and use of any such bug fixes, upgrades or new releases is subject to all of the applicable terms and conditions of Enfora’s technical support policy as posted and updated on its website. Exceptions and Disclaimers Enfora shall have no obligation under this limited warranty for (a) normal wear and tear, (b) the cost of procurement of substitute products or (c) any defect that is (i) discovered by purchaser during the warranty period but purchaser does not notify or request an RMA number from Enfora, as required above, until after the end of the warranty period, (ii) caused by any accident, misuse, abuse, improper installation, handling or testing, or unauthorized repair or modification of the product, (iii) caused by use of any software other than any software supplied by Enfora, or by use of the product other than in accordance with its documentation or (iv) the result of electrostatic discharge, electrical surge, fire, flood or similar causes. Unless otherwise provided in a written agreement between the purchaser and Enfora, the purchaser shall be solely responsible for the proper configuration, testing and verification of the product prior to deployment in the field. ENFORA’S SOLE RESPONSIBILITY AND PURCHASER’S SOLE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE TO REPAIR OR REPLACE THE PRODUCT HARDWARE, SOFTWARE OR SOFTWARE MEDIA (OR IF REPAIR OR REPLACEMENT IS NOT POSSIBLE, OBTAIN A REFUND OF THE PURCHASE PRICE) AS PROVIDED ABOVE. ENFORA EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF NONINFRINGEMENT, MERCHANTABILITY, SATISFACTORY PERFORMANCE AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ENFORA BE LIABLE FOR ANY INDIRECT, SPECIAL, EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOSS OR INTERRUPTION OF USE, DATA, REVENUES OR PROFITS) RESULTING FROM A BREACH OF THIS WARRANTY OR BASED ON ANY OTHER LEGAL THEORY, EVEN IF ENFORA HAS BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES. 12.3. Other Considerations Some jurisdictions may require a longer warranty period than specified above and, accordingly, for products sold in those jurisdictions the applicable warranty period shall be extended as required under the laws of those jurisdictions. Furthermore, some jurisdictions may not allow the disclaimer of implied warranties or the exclusion or limitation of incidental or consequential damages, so the above disclaimer, limitation or exclusion may not apply to products sold in those jurisdictions. This limited warranty gives the purchaser specific legal rights and the purchaser may have other legal rights that vary from jurisdiction to jurisdiction. In some instances, certain aspects of the product warranty may also be covered in a separate written agreement between Enfora and the distributor or reseller, if any, from whom purchaser purchased the product. That agreement may provide, for example, a different product return procedure that may also be available to purchaser (e.g., the product may be returned to Enfora through that distributor or reseller). GSM0308PB001 80 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Governing Law This limited warranty shall be governed by the laws of the State of Texas, United States of America, without regard to conflict of laws principles. This limited warranty shall not be governed in any respect by the United Nations Convention on Contracts for the International Sale of Goods. GSM0308PB001 81 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13. APPENDIX B - Regulations and Compliance This section summarizes the responsibilities and actions required of manufacturers and integrators who incorporate OEM versions of the Enfora Enabler III-G module into their products. In certain situations and applications, these products will require additional FCC, CE, GCF, PTCRB or other regulatory approvals prior to sale or operation. Appropriate instructions, documentation and labels are required for all products. For more information concerning regulatory requirements, please contact Enfora. 13.1. GCF/PTCRB Approval (Formerly FTA) The Enfora Enabler III-G module is type approved in accordance with the requirements of and through the procedures set forth by the GSM industry association. The relevant conformance specification is 3GPP TS 51010-1. Any OEM changes in the SIM interface, antenna port, software or the physical makeup of the unit may require an incremental FTA to ensure continued compliance with the above-mentioned standard. For more information concerning type approval, please contact Enfora. 13.2. Electromagnetic Compatibility (EMC) and Safety Requirements The Enfora Enabler III-G module has been tested and approved for application in the United States of America (US) and the European Union (EU). The compliance details for each of these markets follow. For other markets, additional or alternative regulatory approvals may be required. Always ensure that all rules and regulations are complied with in every country that the OEM application is to be operated. Regardless of the country or market, the OEM must comply with all applicable regulatory requirements. 13.3. EMC/Safety Requirements for the USA Compliance to the US rules and regulations falls under two categories: • Radio approvals: Federal Communications Commission (FCC) • Transmitter: FCC Rules, Part 22 & 24 • Unintentional emission: FCC Rules, Part 15 Although the Enfora Enabler III-G module has been authorized by the FCC and listed as a component by an NRTL, products and applications that incorporate the Enfora Enabler III-G module will require final verification of EM emission and product safety approval. Note: Particular attention should be made to the following statements regarding RF Exposure: GSM0308PB001 82 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13.4. Human Exposure Compliance Statement GSM0308 GSM/GPRS Module Enfora certifies that the Enfora Enabler III-G 850/900/1800/1900 MHz GSM Radio Module (FCC ID: MIVGSM0308) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24, Subpart E and Part 22 of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler III-G module and its host product in accordance with all instructions provided to both the OEM and end user. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler III-G module meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations. Note: Installation and operation of this equipment must comply with all applicable FCC Rules and Regulations, including those that implement the National Environmental Policy Act of 1969 (Part 1, Subpart I), with specific regard to antenna sitting and human exposure to radio frequency radiation. For further guidance, consult the FCC Rules, a certified FCC test house, or Enfora. 13.5. Compliance with FCC Regulations The Federal Communications Commission (FCC) is the agency of the Federal Government that oversees all non-governmental radio frequency transmitters that operate within the United States. Unintentional emissions from digital devices are regulated by Part 15 of the FCC Rules and Regulations, which distinguishes between the environments in which these devices may operate. Intentional radiators operating as a GSM-1900 radio transmitter are regulated under Part 22 & 24, Subpart E—Broadband PCS of the FCC Rules and Regulations. GSM0308PB001 83 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13.6. Unintentional Radiators, Part 15 Equipment designated as Class A is intended for use in a commercial, industrial or business environment. The Enfora Enabler III-G module has been tested and found to comply with the limits for a Class A digital device and can be integrated into equipment or applications intended for use in commercial, industrial or business environments. The following statement must be included in the user manual for such products: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Equipment intended for use in a residential environment (not-withstanding use in commercial, industrial or business environments) is designated as Class B. The Enfora Enabler III-G module has been tested and found to comply with the limits for a Class B digital device and can be integrated into equipment or applications intended for use in residential environments. The following statement must be included in the user manual for such products: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 13.7. Intentional Radiators, Part 22 & 24 Products incorporating the Enfora Enabler III-G transceiver operate as Personal Communications Services (PCS) devices under the authority of Part 22 & Part 24, Subpart E—Broadband PCS, of the FCC Rules and Regulations. All such transmitters must be authorized by the FCC through its Certification process, as detailed in Part 2, Subpart J - Equipment Authorization Procedures. Through the Certification process, the FCC verifies that the product complies with all applicable regulatory and technical requirements, including those that address human exposure to radio frequency radiation. In general, radio frequency transmitters cannot be sold or operated in the US prior to FCC approval. GSM0308PB001 84 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13.8. Instructions to the Original Equipment Manufacturer (OEM) To comply with the requirements of the National Environmental Policy Act (NEPA) of 1969, operation of an FCC-regulated transmitter may not result in human exposure to radio frequency radiation in excess of the applicable health and safety guidelines established by the FCC. Further information on RF exposure issues may be found in the FCC's Office of Engineering and Technology (OET) Bulletin Number 65, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields" and Supplement C, "Additional Information for Evaluating Compliance of Mobile and Portable devices with FCC Limits for Human Exposure to Radio Frequency Emissions.” Both of these documents are available via the Internet at the OET web site: http://www.fcc.gov/oet The Enfora Enabler III-G products are GSM radio transceivers, which operate under the authority of 47 CFR Part 24, Subpart E and Part 22 of the FCC Rules and Regulations. When installed and operated in accordance with the instructions provided in this manual, these devices comply with current FCC regulations regarding human exposure to radio frequency radiation. The following installation and operation restrictions apply to all Enfora Enabler III-G products: • This device may only be used in fixed and mobile applications. • Portable applications, as defined by the FCC, are prohibited. • The use of this device for desktop and other applications where the antenna can easily be relocated are considered by the FCC to be mobile applications. • A separation distance of at least 20 cm (7.87 inches) between the antenna and the body of the user and other persons must be maintained at all times • In FIXED applications, antenna gain is limited to a maximum of 7 dBi, with a corresponding Equivalent Isotropic Radiated Power (EIRP) of 37 dBm / 5 W. • In MOBILE applications, antenna gain is limited to a maximum of 3 dBi, with a corresponding EIRP of 33 dBm / 2 W. • End products must provide instructions to ensure compliance with radio frequency radiation exposure requirements. • A warning label visible to all persons exposed to the antenna and identical to that described in this manual must be displayed on or next to the antenna. • Separate FCC approval for RF exposure compliance is required for end products that do not meet these conditions. Antenna gain is defined as gain in dBi (dB referenced to an isotropic radiator) minus cabling loss. GSM0308PB001 85 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Note: Additional care must be taken by the installer and/or user of the Enfora Enabler III-G products to ensure proper antenna selection and installation. Adherence to the above conditions is necessary to comply with FCC requirements for safe operation regarding exposure to RF radiation. Depending upon the application and type of product into which the Enfora Enabler III-G module has been incorporated, specific OEM actions and responsibilities required to meet these conditions vary. However, in all cases the primary concern is to ensure compliance with current FCC guidelines and regulations that limit human exposure to radio frequency radiation. Definitions For the purpose of determining compliance with current FCC rules addressing human exposure to radio frequency radiation, the FCC has established the following three categories of transmitting devices: GSM0308PB001 • Portable Devices – devices where the antenna is located within 20 cm (7.87 inches) of any person, including the user, if applicable. Portable devices operating under the authority of Part 22 or 24 (broadband PCS) are limited to a maximum of 2 W EIRP. • Mobile Devices – devices designed to be used in other than fixed locations and generally such that the antenna is located at a minimum of 20 cm (7.87 inches) from any person, including the user, if applicable. Mobile devices operating under the authority of Part 22 or 24 (broadband PCS) are limited to a maximum of 2 W EIRP. • Fixed devices – devices in which the antenna, either integral to the product or remotely located, is physically secured at one location and is not able to be easily moved to another location. The antenna for a fixed device is mounted on an outdoor, permanent structure with a minimum separation distance of 2 meters (79 inches) 86 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13.8.1. OEM Responsibilities for All Products Containing the Enabler III-G module In addition to any other regulatory requirements, OEMs and integrators must include or provide the following information, instructions, warnings and labels with any device or product into which the Enfora Enabler III-G GSM1900 GSM transceiver has been incorporated: Information Detailed Operating Instructions for ensuring compliance with current FCC guidelines which limit human exposure to radio frequency radiation Antenna Avoidance Label Human Exposure Compliance Statement GSM0308PB001 Description The OEM must provide an operating/installation manual with the final product which clearly indicates that these operating conditions and restrictions must be observed at all times to ensure compliance with current FCC guidelines which limit human exposure to radio frequency radiation. 20 cm (7.87 inch) separation distance between the antenna and all persons must be maintained at all times for all fixed and mobile products and applications Portable devices and applications are prohibited unless such devices and products are specifically authorized by the FCC Maximum antenna gain is limited to 2 dBi* in mobile products and applications For fixed applications (2 meter separation) the antenna gain can be as much as 26 dBi. Modifications and/or additions to the Enfora Enabler III-G GSM transceiver, including use of antennas with higher gain than those authorized by the FCC, are prohibited *dBi = antenna gain in dB relative to an isotropic radiator Attach the following warning label directly to or displayed next to the WARNING antenna. Furthermore, this label must To comply with FCC RF be visible to and easily readable by all exposure requirements, a persons in the immediate vicinity of the separation distance of 20 cm antenna (7.87”) or more must be maintained between this antenna and all persons Include the following statement in the instruction / operation manual. 87 Enfora certifies that the Enfora Enabler III-G ™ MHz GSM Radio Module (FCC ID: MIVGSM0308) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 22 or Part 24, Subpart E of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler III-G module and its host product in accordance with all instructions provided to both the OEM and end used. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler III-G module meets the Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations. 13.8.2. Specific OEM Responsibilities for Portable Products and Applications Each device or product, into which the Enfora Enabler III-G PCS-1900 GSM transceiver has been incorporated, and which is intended to be used in an application that meets the definition of "portable" MUST be separately authorized by the FCC for the purposes of determining compliance with current FCC guidelines limiting human exposure to radio frequency radiation. Portable devices must be evaluated for RF exposure based on Specific Absorption Rate (SAR) limits; further information on such evaluations are available from the FCC via the Internet. 13.8.3. Specific OEM Responsibilities for Mobile Products and Applications Separate or additional FCC approvals are NOT required for devices or products, into which the Enfora Enabler III-G PCS-1900 GSM transceiver has been incorporated, that are used in applications that meet the definition of "mobile." For all end products, the OEM or integrator must provide instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation. Current FCC regulations limit the EIRP of mobile devices to 2 W. Because the nominal RF output power of the Enfora Enabler III-G GSM1900 GSM transceiver is 1.0 W (30 dBm), antenna gain for mobile products and applications cannot exceed 3 dBi. 13.8.4. Specific OEM Responsibilities for Fixed Products and Applications Separate or additional FCC approvals are not required for devices or products, into which the Enfora Enabler III-G GSM transceiver has been incorporated, that are used in applications that meet the definition of "fixed.” For all end products, the OEM or integrator must provide the instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation. Separate or additional FCC approvals are required for devices or end products used in fixed applications where antenna gain in excess of 7dBi is desired. GSM0308PB001 88 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 13.9. EMC/Safety Requirements for the Countries of the European Union (EU) The European Union (EU) is comprised of fifteen countries that follow a harmonized set of standards, utilizing the CE mark as a uniform mark of acceptance. The member countries are: • • • • • • • • • • • • • • • 13.10. Austria Belgium Denmark Finland France Germany Greece Ireland Italy Luxembourg The Netherlands Portugal Spain Sweden United Kingdom EMC/Safety Requirements for Other Countries In most other countries that have not been listed above there are similar rules and regulations that must be met for importing the Enfora Enabler III-G module. Each may require a different mark of approval (for example, the CB Scheme) as an acceptance requirement. For each of these cases the country should identified, and the appropriate steps should be taken to meet the requirements set forth in the intended market. GSM0308PB001 89 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 14. APPENDIX C - Glossary and Acronyms API App Application AT Command Set BER Bit Error Rate CMUX CPE Customer Premise Equipment CSD Circuit Switched Data dBi DCE Data Communications Equipment DCS Digital Cellular System DTE Data Terminal Equipment EFR Enhanced Full Rate EIR Equipment Identity Register EIRP Equivalent Isotropic Radiated Power EMC Electromagnetic Compatibility ESD Electrostatic Discharge EU European Union FTA Full Type Approval GPRS General Packet Radio Service GSM Global System for Mobile Communications HLR Home Location Register IMEI International Mobile GSM0308PB001 Application Programming Interface. Refers to the Application which sends or receives commands/responses from the Enfora Enabler III-G Module Commands issued by intelligent device to a modem to perform functions, such as to initiate call, to answer call, or to transmit data. Bit Error Rate Multiplexer protocol that operates between an MS and a TE and allows a number of simultaneous sessions over a normal serial asynchronous interface A terminal in fixed location on the customer’s premises. Data link from a terminal through the network allowing real-time, duplex connectivity at 9600 bytes/second. Decibels referenced to an isotropic radiator Data Communications Equipment A collection of services and capabilities providing flexibility of access and mobility through a combination of wireless and wire-line networks, utilizing the 1800 MHz bandwidth. Data Terminal Equipment Voice (vocoder) compression algorithms which offer the highest quality voice communication. A database used to store International Mobile Equipment Identity (IMEI) of a locally issued terminal. In a given direction, the gain of a transmitting antenna multiplied by the net power accepted by the antenna from the connected transmitter. The ability of a device to function satisfactorily in its electromagnetic environment without inducing intolerable disturbance to that environment (or to other devices) Static electricity that can damage electronic equipment. An organization of 15 European states whose purpose is to organize relations between the Member States and between their peoples. GSM Full Type Approval Standard for packet communications utilizing Global Standard for Mobility (GSM) infrastructure. Standard for digital communications. Allows consistent communications in various parts of the world despite variations in RF spectrum allocations. Transferring the SIM (see below) permits users to roam by changing terminal equipment. Stores the identity and user data for all subscribers belonging to the area of the related MSC. A unique number for each GSM Terminal tracked by the GSM operators in their Equipment Identity Register (EIR) database. 90 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide Equipment Identity IMSI International Mobile Subscriber Identification Ki MO Mobile Originated MT Mobile Terminated MSC Mobile Switching Center Non-Transparent Mode NRTL Nationally Recognized Test Laboratory OEM PA Packet PCS PDA PDU PPP SIM SMS SMSC SUPL UDP GSM0308PB001 A unique number identifying the subscriber stored in the SIM card. Number is used in conjunction with the network for call routing. A secret code used in authentication and encryption by the terminal. Any GSM/GPRS service originated at the mobile terminal. Any GSM/GPRS service originated from or routed through the network and sent to the mobile terminal. The central switch of the GSM network. Performs call routing, collects call detail records for billing, and supervises system operations. Delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed PSTN line. OSHA-approved Nationally Recognized Testing Laboratory Original Equipment Manufacturer. Power Amplifier. A collection of data transmitted over a digital network in a burst. Personal Communication Services. Personal Digital Assistant. Packet Data Unit. Point-To-Point Protocol. Subscriber Identity Module. Short Message Service. Short Message Service Center. Secure User Plane Location User Datagram Protocol. 91 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 15. APPENDIX D – Tables and Figures TABLES Table 1 - Enabler III-G Key Features ............................................................................................................ 9 Table 2 - Enabler III-G Pin Assignments..................................................................................................... 28 Table 3 - Modem Library Configurations..................................................................................................... 68 FIGURES Figure 1 – UDP API Architecture ................................................................................................................ 11 Figure 2 - PAD Architecture ........................................................................................................................ 12 Figure 3 - Enabler III-G Module Block Diagram .......................................................................................... 16 Figure 4 – Front of Module (Board-to-Board RF Conn. Version)................................................................ 21 Figure 5 - Pin 1 Reference, 100-Pin I/O Connector.................................................................................... 22 Figure 6 – Front of Module (Coaxial RF Conn. Version) ............................................................................ 23 Figure 7 - Back of Module (Option SIM Shown) ......................................................................................... 24 Figure 8 – Module Mounting ....................................................................................................................... 25 Figure 9 - Host Pads for Board-To-Board RF Connector ........................................................................... 26 Figure 10 - Ring Indicate Timing................................................................................................................. 32 Figure 11 - External Power Control Signal (no external processor) ........................................................... 33 Figure 12 - External Power Control Signal (using external RC circuit) ....................................................... 34 Figure 13 - Power Control Signal (using external processor) ..................................................................... 35 Figure 14 - Typical Power On Sequence (using external processor) ......................................................... 36 Figure 15 – LED voltage driver circuit......................................................................................................... 41 Figure 16 - Remote SIM Interface............................................................................................................... 57 Figure 17 - UDP-API Structure ................................................................................................................... 65 Figure 18 - Library Layout ........................................................................................................................... 67 Figure 19 - Using Port Library..................................................................................................................... 68 Figure 20 - Using Messaging Library .......................................................................................................... 68 Figure 21 - Using Modem Library ............................................................................................................... 70 Figure 22 - HyperTerminal Definition .......................................................................................................... 71 Figure 23 - COM Port Settings.................................................................................................................... 72 GSM0308PB001 92 Version DRAFT – 2/9/2007 Enfora Enabler III-G Modem Integration Guide 16. APPENDIX E - Contacting Enfora For technical support and customer service dealing with the modem itself, contact the company where you purchased the product. If you purchased the product directly from Enfora, visit the SUPPORT page on the Enfora website: http://www.enfora.com/support_newissue.asp GSM0308PB001 93 Version DRAFT – 2/9/2007
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 98 Page Layout : OneColumn XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:e3e61194-1952-4958-a049-411e6634cf29 Producer : Acrobat Distiller 7.0.5 (Windows) Company : Enfora, LLP Source Modified : D:20070209163337 Headline : Create Date : 2007:02:09 10:43:56-06:00 Creator Tool : Acrobat PDFMaker 7.0.7 for Word Modify Date : 2007:02:09 15:59:02-06:00 Metadata Date : 2007:02:09 15:59:02-06:00 Document ID : uuid:d084f326-ae1d-4f89-b8fd-f53dce92841d Instance ID : uuid:a4efab6a-7cc1-4277-83a0-17de3ca064f2 Version ID : 9 Format : application/pdf Title : Enabler II-G Assiste GPS Integration Guide Creator : Matt Glover Subject : Tagged PDF : Yes Author : Matt GloverEXIF Metadata provided by EXIF.tools