Nyce Sensors Z30411 MOTION SENSOR WITH ZIGBEE RADIO User Manual NCZ 3041 manual

Nyce Sensors Inc. MOTION SENSOR WITH ZIGBEE RADIO NCZ 3041 manual

Users Manual

Download: Nyce Sensors Z30411 MOTION SENSOR WITH ZIGBEE RADIO User Manual NCZ 3041 manual
Mirror Download [FCC.gov]Nyce Sensors Z30411 MOTION SENSOR WITH ZIGBEE RADIO User Manual NCZ 3041 manual
Document ID1600707
Application IDxoKbXcGEClx3NFMIIeaasQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize6.68kB (83478 bits)
Date Submitted2011-12-12 00:00:00
Date Available2011-12-12 00:00:00
Creation Date2011-11-25 07:48:20
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2011-11-25 07:48:20
Document TitleMicrosoft Word - NCZ-3041_manual.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: mvogel

NCZ-3041 MOTION SENSOR
User Guide
Product Summary:
Nyce Control’s NCZ-3041 is a wireless motion sensor using the ZigBee radio protocol. It is used in
conjunction with a low RF transmit power wireless ZigBee network to monitor the occupancy state of
indoor areas, and provide this information to other devices operating in a ZigBee Home Automation
network.
• Button functions: Identify/join Network
• Accurate battery voltage level measurement and reporting back to co-ordinator
• Network operation based on the ZigBee open profile Home Automation
• Up to 4 years projected battery life
Specifications:
Detection Range
5m
Horizontal Detection Range
+/- 47°
Vertical Detection Range
+/- 41°
Installation Guidelines:
•
If using double sided tape for mounting sensor, thoroughly clean the surface to ensure proper
adhesion because dust and particles can reduce the adhesion of the tape
•
Open the case and insert the battery, noting the correct polarity. Close the cover.
•
Place the NCZ-3041 indoors and away from sources of water/moisture and extreme weather
conditions
•
Press the button once to join the network
•
Snap in front cover to mounted rear cover.
Placement Guidelines:
Place the motions sensor facing where you want to detect motion. Measurements below are approximate.
Top View
100°
Bottom View
41°
6’
2.9’
15’
Troubleshooting:
To improve communication:
•
Reposition the sensor
•
Relocate the sensor
•
Move a ZigBee router / range extender closer to the sensor
•
If necessary, replace the sensor
Technical Specifications:
•
Model Number: NCZ-3041
•
Battery Type: 3.0 V CR2 850 mAhr Lithium
•
RF Frequency: ZigBee channels 11-26, 2.48 GHz
•
Operating Temperature: -10 C to 50 C (14 F to 122 F)
•
Dimensions: 20mm x 29mm x 65mm
Battery Replacement:
•
Remove front cover to expose battery
•
Replace with 3.0 volt CR2 850 mAhr Lithium, noting the correct polarity of the battery
Button Functionality:
Action
ZED State
Press and release once
Not joined to any network
Description
Attempt to join the a Home
Automation profile network
(Open Standard)
Press and release two
Joined to the network
Identify to the network
Identifying to the network
Stop Identifying, form Group.
Any state
LED flashes indicate whether
times
ZED is joined to a network or
not.
Press and release four
Not joined to any network
times
Attempt to join a Control 4
network
Press and release six
Joined to a Control 4 or
Leave the network
times
Open Standard network
Press and release ten
Any state
Reset to factory settings.
Press and hold for 4
Joined to a Control 4
Leave Control 4 network
seconds
network
times
LED Indicators:
Colour
Behaviour
Description
Failed to join a network, or forced to
Flash 2 times
button presses)
Red
Flash once
Initial detection of Occupancy or Motion
Flash 3 times
Provisioning failed
Flash 2 times
Green
Orange
leave, or not joined when queried (2
Successfully joined a Home Automation
Network, or is currently joined
Flash 3 times
Provisioning succeeded
Flash 5 times
Successfully reset to factory defaults
Flash 2-5 Hz
Identify mode
Flash 1 time
Unsupported button command
Flash 5 times
Communication or device error
MODEL #: NCZ-3041
FCC ID: Y8R-Z30411
IC ID: 9488A-Z30411
Compliance Statements:
For complete declarations and certifications please visit:
www.nycecontrol.com/compliance
Notices
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user’s authority to operate the
equipment.
Changes or modifications not expressly approved by NYCE Control, Inc can void the user’s authority to
operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is Subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Warranty:
For product warranty information please visit:
www.nycecontrol.com
Support:
For product support please email:
support@nycecontrol.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 5
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2011:11:25 07:48:20
Modify Date                     : 2011:11:25 07:48:20
Title                           : Microsoft Word - NCZ-3041_manual.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : mvogel
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Y8R-Z30411

Navigation menu