OENONEO 8385OENO Wine Scanner User Manual

OENONEO Wine Scanner

User manual.pdf

 USER MANUAL  MYOENO SCAN Instructions: 1.  Press  the  button  on  the  top  of  the product. A light will flash in the slot at the bottom of the product. 2.  Using  your  smartphone,  launch  the MYOENO application. 3.  After  creating  your  user  account, click the “TEST A WINE” icon. 4.  A  Bluetooth  activation  request  will appear.  Accept  it.  A  green  checkmark  will appear in the “BLUETOOTH® ACTIVE” icon.  5.  The  first  time  you  connect  your smartphone  to  MyOeno  Scan,  click on  the icon at the top right of the screen. A list of nearby Bluetooth® devices will appear. If it does not appear, click “SEARCH”. 6. Select  your  MyOeno  Scan,  shown  as MYOENO-XXXXX.  When  the  connection  is established, a checkmark will appear in the “CONNECTED DEVICE” icon. 7. When the device is connected, it will calibrate  automatically  (succession  of green, red, and blue colors), then the light will remain green.  Please note,  if  the MyOeno Scan slot  turns yellow and  starts to recalibrate, you are in an  environment  with  too  much  and/or changing light. To avoid this, set down your MyOeno  Scan  and  position  it  so  that  it  is not exposed to direct and/or unstable light. 8.  When  the  scan  light  is  solid  green, dip  the  device’s  slot  completely  into  the wine.  The  measurement  is  performed automatically. Please  note,  if  the  immersion  lasts  more than  five  (5)  seconds,  the  measurement conditions  are  not  optimal  (the environment  has  too  much  and/or changing  light).  Be  careful  not  to  move your  MyOeno  Scan  around  in  your  glass and  do  not  expose  it  to  direct  and/or unstable light. 9.  When  the MyOeno  Scan  slot  is  fully immerged  for  a  few  seconds,  the  triangle that  characterizes  the wine  will  appear  on your  smartphone,  and  you  can  remove MyOeno  Scan from  the  wine.  Please  note, you  must  have an  internet connection  and you  need  to  have  completed  all  the  wine identification  fields  in  order  to  “CONFIRM” your  tasting  form.  If  you  do  not  have  the information  required  to  fill  in  all  of  the fields  (Domain,  Vintage,  Country,  Region Designation), enter “--“. 10.  Press  the  button  to  turn  off  the product, or return to step 3 to test another wine.  Recharging: If  the  MyOeno  Scan  starts  flashing  red,  it needs to be recharged using the USB cable provided.  As  it  recharges,  MyOeno  Scan flashes  green.  When  the  charge  is complete, the light is solid green. In  the  “TEST  A  WINE” function,  when  the connection  is  established,  the  MyOeno Scan  battery  level  is  indicated  at  the bottom right of the screen. Maintenance/Cleaning: We  recommend  that  you  clean  your MyOeno Scan after every use by immersing it  in  a  glass  of  water.  Do  not  clean  your MyOeno  Scan  with  abrasive  material  or solvents. Before turning on the MyOeno Scan, make sure that the slot (measuring area) is clean and  dry  using  the  microfiber  cloth provided.  This  ensures  proper calibration,  and  reliable  and  reproducible measurements. The  information  provided  by  MyOeno Scan: STRENGTH:  Mix  between  the  alcoholic strength  and  the  body  of  the  wine  / TANNINS: Sensation of astringency / ACIDITY: Sensation of acidity. These parameters are shown on a 100-point scale. CELLARING  POTENTIAL:  Estimation  of  the bottle’s aging potential. EVOLUTION: Information about the youth of the wine. Shown on a 100-point scale. The higher  the  value,  the  more  the  wine  has evolved (aged). To contact us: contact@myoeno.com Safety instructions: -  The  upper  part  of  the  MyOeno  Scan  device (the  micro-USB  connector  and  power  button) should not be  exposed to dripping or splashing water.  /  -  If  the  product’s  power  cord  gets damaged, have it repaired by the manufacturer, the after-sales service, or any other party with a similar  qualification  in  order  to  avoid  any danger.  /  -  In  the  event  that  the  product malfunctions, it  must  be  replaced  because  it is not repairable. / - The device is not intended for use by people (including children) with reduced sensory  or  mental  abilities,  or  by  people without  experience  or  knowledge,  unless  an intermediary  responsible  for  their  safety provides  supervision  or  instructions  concerning the  use  of  the  device.  /  -  Children  should  not play  with  MyOeno  Scan  and  should  be  under adult supervision. / - The device is intended for use in temperate climates only. / - The ambient temperature for use is between 0° C and 35° C. / - The device mustn’t be exposed to excessive heat such as sun, fire, or the like. / - The battery must  not  be  replaced  by  the  user.  Do  not connect  the  device  to  a  USB  3.0  port  to recharge  the  battery.  /  -  The  external  circuits used  to  charge  the  product  must  have  a  SELV system  (Safety  Extra  Low  Voltage)  and  be limited power sources according to chapters 2.2 and 2.5 of the IEC standards 60950-1:2005 (2nd Edition)  +  Am  1:  2009  +  Am  2:  2013    and  EN 60950-1:  2006  +  Am  11:  2009  +  Am  1:  2010  + Am  12:  2011  +  Am  2:  2013.  /  -  The  European Directive  2019/13/EU  on  Waste  Electrical  and Electronic  Equipment  (WEEE)  states  that  used appliances  should  not  be  discarded  along  with the  normal  flow  of  municipal  waste.  Used appliances must be collected separately in order to  optimize  the  recovery  rate  and  recycling  of the  materials  that  compose  them,  and  to reduce  the  impact  on  human  health  and  the environment.  The  crossed-out  trash  can  symbol  is  affixed  to all  products  to  remind  people  of  the  separate collection requirements. This  device  complies  with  Part  15  of  the  FCC Rules. Operation is subject to the following two conditions:  (1)  this  device  may  not  cause harmful  interference,  and  (2)  this  device  must accept  any  interference  received,  including interference  that  may  cause  undesired operation. / Caution: the user that  changes or modifications  not  expressly  approved  by  the party responsible for compliance could void the user's  authority  to  operate  the  equipment.  / "NOTE:  This  equipment  has  been  tested  and found  to  comply  with  the  limits  for  a  Class  B digital  device,  pursuant  to  part  15  of  the  FCC Rules.  These  limits  are  designed  to  provide reasonable  protection  against  harmful interference  in  a  residential  installation.  This equipment  generates,  uses  and  can  radiate radio frequency energy and, if not installed and used  in  accordance  with  the  instruction,  may cause  harmful  interference  to  radio communications.  However,  there  is  no guarantee  that  interference  will  not occur  in  a particular  installation.  If  this  equipment  does cause harmful interference to radio or television reception  which  can  be  determined  by  turning the  equipment  off  and  on,  the  user  is encouraged  to  try  to  correct  interference  by one  or  more  of  the  following  measures:  -Reorient  or  relocate  the  receiving  antenna.  -Increase the separation between the equipment and  receiver.  -Connect  the  equipment  into  an outlet  on  circuit  different  from  that  to  which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.  This  device  complies  with  FCC  radiation exposure limits set forth for general population. This device must not be co-located or operating in  conjunction  with  any  other  antenna  or transmitter. Symbol Meaning  The  CE  marking  indicates compliance  with  European directives.  Selective  sorting  of  waste  for recycling  electrical  and electronic  equipment  within the  European  Union.  In accordance  with  the  WEEE Directive  2002/96/EC:  this material  should  not  be treated as household waste.

Navigation menu