OPISYS orporated USHR-700L In-Building Repeater System User Manual Revised

OPISYS Incorporated In-Building Repeater System Users Manual Revised

Users Manual Revised

Download: OPISYS orporated USHR-700L In-Building Repeater System User Manual Revised
Mirror Download [FCC.gov]OPISYS orporated USHR-700L In-Building Repeater System User Manual Revised
Document ID2446934
Application ID1n0OMWihhEZkPoav2Y2DQg==
Document DescriptionUsers Manual Revised
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize65.84kB (822947 bits)
Date Submitted2014-11-17 00:00:00
Date Available2015-01-03 00:00:00
Creation Date2014-11-14 16:41:35
Producing SoftwareAdobe PDF Library 10.0
Document Lastmod2014-11-14 18:11:08
Document TitleEZ CELL 사용설명서 (MODEL : AEHR-2009)
Document CreatorPowerPointìš© Acrobat PDFMaker 10.1
Document Author: 아이솔

Users Guide
Installation Manual
USHR-700L
- Content 1. General Information
2. System Components
3. Installation
4. Trouble Shooting
5. Specification
6. Certificates
7. Memo
This is a CONSUMER device.
BEFORE USE, you MUST REGISTER THIS DEVICE with your wireless
provider and have your provider’s consent. Most wireless providers consent to
the use of signal boosters. Some providers may not consent to the use of this
device on their network. If you are unsure, contact your provider.
You MUST operate this device with approved antennas and cables as specified
by the manufacturer. Antennas MUST be installed at least 20 cm (8 inches)
from any person.
You MUST cease operating this device immediately if requested by the FCC or
a licensed wireless service provider.
WARNING. E911 location information may not be provided or may be
inaccurate for calls served by using this device.
Page 2
1. General Information
1.1. Precautions
Reference : Direction/Information for the proper operation
Cautions : Information for users to avoid malfunctions
Warning : Instruction for users to avoid unexpected hazard
1.1.1 Do not drop the device
- It may damage the product and its function
1.1.2 Do not place near magnetic material
- It may cause of possible malfunction
1.1.3 Product is recommended to be used with original AC/DC adapter
1.1.4 Install the product where it is recommended
- It may not properly operate if it is not recommended location
1.1.5 Do not disassemble/ repair the product
- Warranty may void once you disassemble the product.
1.1.6 Turn off the device immediately if a smog or any strange odor is
detected from the product.
1.1.7 Use contained bolt to install on the wall. Make sure it is safely
installed before operation
Page 3
1.2 . Features
1.2.1. Summary
This device may be installed on residential area, office, warehouse etc. .
Following is advantage of using in-building repeater system.
I.
Decrease dropped call rate
II.
Increase signal strength
III. Improve Data / Voice quality
IV. Prolong hand phone battery life
V.
Improve data Communication Rate
This is RF type amplifier for 700 MHz LTE of Band 12 and Band 13 signal
enhancement.
(Please see page 13 for Operating Frequency in details)
1.2.2 . Features
I.
Wider Coverage area
- Band 12 Gain DL 61dB /UL 60dB, Band 13 Gain DL 61dB/ UL 60dB.
II.
ALC(Automatic output Level Control)
- Stabilize operation in any radio environment
III. Fulfill 3GPP spurious specification at +22dBm output power
(category A)
- Provide high Data Communication Rate
IV.
Easy gain control by dip switch located on the front side of product
V.
Support dual band
- enable to connect service from multiple currier simultaneously
- LTE Band 12/13 service simultaneously
- LTE Band 12/13 adopt independent operation algorithm
VI. Check status of product by LED indicator
VII. Manage and control product by GUI(Graphic User Interface)
- Please ask professional installer about GUI Program
VIII. Enable to stay connected in homes and offices
- Please ask professional installer for installation on homes & offices
IX.
X.
LTE ready
Automatically isolation detection and gain setting
- Power ON/OFF when oscillation occurs.
XI. UP Link Sleep Mode
- If no signal detected for 5 minutes, UP Link Path Shuts Off
XII. UL/DL gain Interlocking Mode
Page 4
1.2.3. Function
I.
S/D ( Auto Shut Down Mode)
Built-In Automatic Self-Monitoring Features for Anti-Oscillation:
Automatic Shut Down Mode operates when oscillation in the uplink and downlinks bands
are detected, thus terminates potential harmful interference to wireless networks.
•
1 MINUTE Non-Operative Mode on the first initial oscillation detection.
•
Default Algorithm Re-Set Mode when Auto S/D Mode is cleared
•
Complete Shut Off Mode on the 5th repetition of Auto S/D Mode status.
BAND 12 & BAND 13 PATH are independently monitored and operated.
II.
Intermodulation Gain & Power Limit Control
Uplink & Downlink PATH formulate consistent link balance to regulate its
input and output gain & power limits.
max UL gain < - 34dB – RSSI + MSCL (“ FCC 13-21,(i), 78p”)
RSSI : the downlink composite received signal power at the donor port
( calculation value : DL Output – DL Gain )
MSCL : Mobile Station and repeater service port minimum Coupling Loss
( setting value )
BAND 12 & BAND 13 PATH gain limits are independently controlled
III. ALC (Automatic Level Control)
ALC is implemented due to the higher rate of signal changes and wide dynamic range in
LTE Bands, the Automatic Gain Power Control (AGC) may experience off set time
synchronization error.
•
Optimal Window Size (frequency range) sets the optimal level to increase
faster response to LTE Frequency changes on the basis of gain power
control via signal input/output differential calculation
BAND 12 & BAND 13 PATH gain limits are independently controlled
IV. UL PATH Automatic Sleep Mode
If coverage is non-existent (Zero Area Zone), Uplink PATH shuts off as A
Harmful Interference Avoidance protocol and minimizes its power
consumption.
Page 4
1.2.3. Function
IV. UL PATH Automatic Sleep Mode (continue )
•
Automatic Turn OFF / if UL PATH < -92dBm
•
Automatic Turn ON / if UL PATH > -90dBm
**BAND 12 & BAND 13 PATH gain limits are independently controlled
V.
Oscillation Auto Prevention
•
Degradation Protection: Detects potential performance degradation due to
the overload LTE feedback (over-heating) signals by Isolation Check & Gain
Configuration.
•
Feedback Limits: Sets the operating range to exceeding high level Signals
from Donor Antenna (external antenna) of a signal booster to Service
Antenna (internal antenna)
BDA Gain < Antenna to Antenna Isolation – 15dB
If optimal isolation gain is not attained, PATH OFF shuts off automatically
**BAND 12 & BAND 13 Uplink PATH are independently controlled
Page 4
2. System components
② AC/DC Adapter
① Dual Band Repeater
④ Installation bolts
③ User Manual
① Dual band Repeater : BTS and mobile phone signal booster
② AC/DC Adaptor : 110VAC power supply
③ User Manual : Operation manual
④ Installation Bolts : Holds repeater on the vertical wall
● List of approved antennas & cables
Antenna
Item
Service Antenna
(Indoor Antenna)
Donor Antenna
(Outdoor Antenna)
RF Cable
Model
Gain
Model
Cable type
PAT-CPWI-L
+4dBi
AC200000
LMR200
TS260771
+8dBi
TS320000
RF240
TS250374
+5dBi
TS340000
RF400
ALP-17QD-L
+6dBi
TS350000
½”
TS210471
+4.5dBi
TS360000
½”
TS220971
+9dBi
Page 5
3. Installation
Out Door Antenna
3.1. Installation diagram
Indoor Antenna
Donor
Antenna
Service
Antenna
BTS
Base satation
USHR-700L
3.1.1. Install Donor Antenna on higher location to avoid any signal
interference. Mount towards to the BTS where a clear line-of-sight
path exists for optimal signal level.
3.1.2. Install service antenna at appropriate location such as wall or
roof ceiling. Make sure service antenna is not blocked by
furniture or hope appliance.
3.1.3. Use enclosed bolt to fix repeater on the wall and plug in power
adaptor.
3.1.4. For best optimal operation, antenna isolation (oscillation level) should be
set above minimum 15 dB gain. The industry standard for antenna to
antenna isolation formula is BDA gain + 15 dB.
3.2. Repeater
Indoor ANT
Port
Band 12
Status LED
POWER
LED
Outdoor
ANT Port
Band 13
Status LED
GUI
PORT
Power
ON/OFF
Switch
POWER Jack
Port
LTE Band12
Gain control
Dip Switch
LTE Band13
Gain control
Dip Switch
Page 6
3.3. Repeater and Antenna connection
3.3.1. Connect donor antenna cable to outdoor antenna port as
shown below.
3.3.2. Connect Service antenna to indoor antenna port as shown below.
3.3.3. Plug in power adaptor to power outlet.
Page 7
3.3.4. Plug in AD/DC adaptor to connector listed as DC5.6V
3.3.5. Once power is on, it will show 3 green LED light on the front of
product as shown below.
LTE Band12
Gain manual control
Dip Switch (0~25dB)
LTE Band13
Gain manual control
Dip Switch (0~25dB)
3.3.6 The factory default set-up has both Automatic Attenuator Control (AAC)
& Automatic Level Control (ALC) pre-activated by USHR-700L Internal CPU.
All Isolation Check features can be manually adjusted via Dip switch using GUI
program (Repeater Control & Monitoring Software).
Page 8
4. Trouble Shooting
4.1. LED Status
Item
GREEN LED
RED LED
Reference
ON
×
See 4.1.1
OFF
×
See 4.1.1
ON
See 4.1.2
ON
See 4.1.3
Green Blinking per 1 sec cycle
See 4.1.4
Green Blinking per 5 sec cycle
See 4.1.5
RED Blinking per 1 sec cycle
See 4.1.6
RED Blinking per 5 sec cycle
See 4.1.7
ON
See 4.1.8
ON
See 4.1.9
Green Blinking per 1 sec cycle
See 4.1.10
Green Blinking per 5 sec cycle
See 4.1.11
RED Blinking per 1 sec cycle
See 4.1.12
RED Blinking per 5 sec cycle
See 4.1.13
PWR
LTE Band 12
LTE Band 13
4.1.1. Power on /off status.
4.1.1. Power on /off status.
4.1.2. Band 12 normal operation condition.
4.1.3. Band 12 detects excessive input signal and shut down.
4.1.4 Shut Down Algorithm status on BAND 12 Signal Input.
4.1.5. PATH OFF indicator during Uplink Sleep Mode for BAND 12.
4.1.6. Isolation SD Algorithm status on Band 12
4.1.7. Band 12 detects Insufficient Isolation between donor & service antenna and shut down.
4.1.8. Band 13 normal operation condition.
4.1.9. Band 13 detects excessive input signal and shut down.
4.1.10 Shut Down Algorithm status on BAND 13 Signal Input.
4.1.11. PATH OFF indicator during Uplink Sleep Mode for BAND 13.
4.1.12. PATH OFF indicator during Uplink Sleep Mode for BAND 12.
4.1.13. Band 12 detects Insufficient Isolation between donor & service antenna and shut down.
Page 9
5. Specification
5.1. Electrical Specification
Item
Frequency Range
Modulation Type
Output Power
Gain
Noise Figure
Noise Power Limit
Down Link
728 ~ 746 MHz
Up Link
698 ~ 716 MHz
Down Link
746 ~ 757 MHz
Up Link
776 ~ 787 MHz
Up Link
-13dBm max
Down Link
-45dBm max
Up Link
-13dBm max
Down Link
+2dBm @ booster output port
LTE DL 5MHz 25RB
Up Link
+22dBm @ booster output port
LTE UL 5MHz 25RB
Down Link
+2dBm @ booster output port
LTE DL 5MHz 25RB
Up Link
+22dBm @ booster output port
LTE UL 5MHz 25RB
Down Link
47dB ~ 61dB (±1.0dB)
Up Link
35dB ~ 60dB (±1.0dB)
Uplink In-activity
BAND12
47dB ~ 61dB (±1.0dB)
35dB ~ 60dB (±1.0dB)
Down / Up Link
< 4dB
BAND12
Down / Up Link
< 4dB
BAND13
Down / Up Link
< 6.0dB / < 6.0dB
BAND12 Max Gain
Down / Up Link
< 6.0dB / < 6.0dB
BAND13 Max Gain
Down Link
< -70dBm/MHz
On shutdown
Up Link
< -70dBm/MHz
On shutdown & sleep mode
Down / Up Link
FCC
BAND12
FCC
BAND13
≤ 1.8 : 1
OSC Level
BAND13
Up Link
VSWR
Shutdown Level
BAND12
Down Link
< 3us
Uplink Gain limit
BAND13
-45dBm max
Down / Up Link
ALC Range
BAND12
Down Link
Propagation Delay
ALC Setting Level
Note
GSM. EDGE, CDMA, EVDO, HSPA, LTE
Input Power limit
Ripple
Specifications
Down Link(Upper Value)
+2dBm±1.0dB
Window Size(Lower Offset)
0 ~ 10dB
Up Link (Upper Value)
+22dBm±1.0dB
Window Size(Lower Offset)
0 ~ 10dB
Down Link
≤ 14dB
Up Link
≤ 25dB
DL starting input level
for Uplink Gain
Interlocking
-68 dBm
Down Link
> -45dBm/Total
Up Link
> -13dBm/Total
Down Link
DL detects OSC under 1 sec.
Up Link
UL detects OSC under 0.3 sec.
Up link
On@ > -90dBm, OFF@ < -92dBm
BAND13
- ALC, SD, OSC functional opera
tion is completely separate BAN
D12 and BAND13.
- No uplink signal for 5 minutes
Page 10
Down Link
0dB ~ 14dB / 1dB step @ Band12
Up Link
0dB ~ 25dB / 1dB step @ Band13
Down link
0dB ~ 25dB / 1dB Step
Up link
0dB ~ 25dB / 1dB Step
ALC
Gain
Control
Range
Dip Switch
Gain Control Deviation
< ± 1dB
EVM
< 7%
Down Link
- be controlled GUI or Dip Switch
- Total Atten control Range :
0dB ~ 25dB / 1dB Step
(Both DL and UL are the same)
No Feedback
≥ 38dB
LTE DL 5MHz 25RB
ACLR (± 10MHz)
Up Link
≥ 32dB
LTE UL 5MHz 25RB
47dB ~ 75dB / BAND12
Isolation checking Range
Detecting deviation: < ±2.0dB
47dB ~ 75dB / BAND13
In band Spurious
(Operating band unwanted emissions)
Category A
3GPP TS 36.106
< -13dBm/1kHz RBW
9kHz ~ 150kHz
< -13dBm/10kHz RBW
150kHz ~ 30MHz
< -13dBm/100kHz RBW
30MHz ~ 1GHz
< -13dBm/1MHz RBW
1GHz ~ 12.75GHz
Out Band Spurious
3rd IMD
< -19dBm
Frequency Stability
≤ ±0.01ppm
GUI Interface
RS-232C
Power Consumption
< 15 W
Operating Power
AC/DC Adapter(AC110V or AC220V)
RF Connector
N-type Female
● Additional Information:
This repeater is a bi-directional amplifier for the boosting of cellular phone signals
and data communication devices.
The following frequency bands and emission types are utilized.
Frequency Band
Uplink
698 ~ 716 MHz
776 ~ 787 MHz
Downlink
728 ~ 746 MHz
746 ~ 757 MHz
Emission Designators
CDMA
HSPA
LTE
EVDO
EDGE
GSM
F9W
F9W
G7D
F9W
G7W
GXW
Page 11
5.2. Mechanical Specification
Item
Specifications
Dimensions (L × W × H)
151mm x 191mm x 35mm
(5.95 x 7.5 x 1.38 inch)
Weight
< 2Kg
Note
5.3. Environment Specification
Item
Specifications
Temperature
-30 ~ 55℃(-22 ~ 131℉)
Humidity
10 ~ 95%
Note
5.4. AC/DC Adaptor Specification
Items
Specifications
AC input power
90VAC ~ 264VAC, 47Hz ~ 63Hz
Output rated Voltage
+5.5VDC/1.3A
Voltage Current range
2.5A ~ 0.0 A
Operation Temperature
-30℃ ~ +55℃
Operation humidity
10% ~ 90%
Note
6. Certificates
6.1 FCC Certification
Model : USHR-700L
▪ Certificate Data :
▪ Certificate Number:
Page 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : 아이솔
Create Date                     : 2014:11:14 16:41:35+09:00
Modify Date                     : 2014:11:14 18:11:08+09:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2014:11:14 18:11:08+09:00
Creator Tool                    : PowerPoint용 Acrobat PDFMaker 10.1
Document ID                     : uuid:4485b420-9b2a-48f5-be57-605836357eb0
Instance ID                     : uuid:61dc52ef-2ea9-4cd6-9684-5ea2e180304a
Format                          : application/pdf
Title                           : EZ CELL 사용설명서 (MODEL : AEHR-2009)
Creator                         : 아이솔
Producer                        : Adobe PDF Library 10.0
Company                         : 중계기팀
Page Layout                     : SinglePage
Page Count                      : 14
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q4EUSHR-700L

Navigation menu